Home
        GWV Series Grid Tie Microinverter User Manual YSmart
         Contents
1.    operation     AY WARNING  This indicates a situation where failure to follow instructions may   k     Follow instruction closely     Safety Instruction    Do not use Smart microinverter in a manner not specified by the manufacturer   Doing so may cause death or injury to persons  or damage to equipment    Perform all electrical installations in accordance with all applicable local electrical  codes    Be aware that only qualified personnel should disassemble and repair the Smart  Microinverters and non qualified personnel should not install and or repair    Do not attempt to repair the Smart Microinverter  it contains no user serviceable  parts  If it fails  contact YSmartcustomer service to claim a return merchandise  authorization and start the replacement process  Tampering with or opening the  Smart Microinverter will void the warranty    If the AC cable connector on the microinverter is damaged or broken  do not install  the unit    Before installing or using the Smart Microinverter  read all instructions and  cautionary markings in the technical description and on the Smart Microinverter  System and the PV equipment    Connect the Smart Microinverter to the utility grid only after you have completed all  installation procedures and after receiving prior approval from the local electrical  utility company    Be aware that the body of the Smart Microinverter is the heat sink  Under normal  operating conditions  the temperature is 15  C above ambient  but under extreme 
2.  conditions the microinverter can reach a temperature of 75  C  To reduce risk of  burns  use caution when working with microinverters    Do NOT disconnect the PV module from the Smart Microinverter without first  removing AC power    The better disconnect DC terminal first  It may cause of components damaged if  removing AC power first when Smart Microinverter still operation  It is available to  disconnect AC power first when Smart Microinverter is not working but the better  to disconnect the DC terminal first    Keep away from children  no touching  no playing so as not to electric shock when  using    Please installed in place of low humidity and well ventilated so as to avoid inverter    overheating  as well as clear around the inflammable and explosive materials     SY GWV Series Smart Grid Tie Microinverter Technical Parameters   Suit  for 72 cells solar panel which Vmp is 35 37V as well as Voc is 44 46V      Efficiency 230VAC 190 260VAC     l Islanding  Short circuit  converse connection  Low Voltage   Protection    Over Voltage  Over temperature Protection    0  90 RH non condensing  E    Grid Detection DIN VDE 1026 UL1741       Mounting dimension 16 13CM    Package        Installation  1  Diagrammatize DC input and AC output terminals     DC Input Positive                                         Cooling Fan  6 Led Indicators   ftp Ano prop a EE A  J re QA S EC MAINS RID TIE INVERTER wan    I  A mamin peice H  7   ck   4 Ful        IR PSwitch  Kies J      SZT  j LA 
3. C connections for positive or negative or not    Check if DC input voltage is within the range of the Smart Microinverter   s  not    Check if the utility grid voltage and frequency are fit in with the serviceable  range of Smart Microinverte or not    Check if fuses of DC side are fusing or not     Check if utility grid voltage properly connecting to Smart Microinverters or    not     DC power supply is normal but no power output     1   Li    Check if utility grid voltage is connecting to Smart Microinverter or not   Check if utility grid voltage is fit in with the serviceable range of Smart  Microinverte or not    Please visual inspection for the LED operation status  red LED will turn off  and green LED will flash or run when inverter connecting with DC power  source which input voltage is fit in with the range as specified and power  grid properly  If still no power output when green LED flash or run  probably  internal components are damaged  in such case  please turn the defective  inverter back for further analyze    Please visual inspection for the LED operation status  red LED still turn on  and green LED without any flash or run when inverter connecting with DC  power source which input voltage is fit in with the range as specified and    power grid properly  probably internal components are damaged  in such    10    case  please turn the defective inverter back for further analyze     YSmart SmartMicroinverter Stack Wiring Diagram    Solar Panel Solar Panel Solar 
4. Panel    Inverter Inverter Inverter    EE HE                  Family Load    YSmart SmartMicroinverter Three Phase output Wiring Diagram    Solar Panel Solar Panel Solar Panel    Inverter GEZ Inverter HS Inverter    z KE   NN Po ee d  7 f T k      f    J c d         a i e    A     1       11    Warranty   Warranty Conditions   Warranty Period  15 year limited warranty period    Warranty Evidence  The B L Tracking no  and a completed warranty card   YSmartgrants an implied warranty of 1 year to the inverter from date of  purchase for repair or replace the Defective Product free of charge includes  freight cost  Furthermore  YSmartprovides an additional limited warranty for 14  years for repair or replace the Defective Product free of charge but non free of  freight charge  If your device has a defect or malfunction during the warranty  period  please also contact your retailer or installer    Warranty claims are excluded for    e Alterations or repairs to the unit without prior authorization   e Improper use or operation of device   e Improper and non standard installation   e operating the equipment with defective safety devices   e Impact of foreign objects and force majeure  lightning  surge  storm  fire    e Inadequate or nonexistent ventilation of the device   e disregarding of safety regulations   e shipping damage   e The Product has been improperly stored or was damaged while in possession  of the Dealer or end user     A WARNING  Only qualified electrical professional
5. YSmart Technology Co  Ltd       GWV Series    Grid Tie Microinverter    User Manual    The copyright of this user manual belong to YSmart TechnologyCompany  Limited  Without the written permission of the copyright holder  any unit or  individual shall not be duplicate  disclosed to others or used  or we will be held  liable in liability  YSmart TechnologyCo   Ltd  has the final say of this user    manual     catalogue    YSmart SmartMicroinverter Introduction                  ccecssseeee eee 1  Important Safety Information    EEN 2 3  Tecnnical Parameters iiic aeia aa ak 4  INStAN ANON EE 5 7  Status Indications Of LED            a sssnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 8  General Iroublesbootmg    een 8  Stack used Method  iriiria aaa 9  EE 10  Product Warranty Card    ee 11  CONMCCH method EE 12    YSmart SmartMicroinverter Introduction    Grid tie inverter is a device which directly converts direct current into sine wave   frequency and phase are same as power grid alternating current and feed into power  grid  It is a key device of power generation system such as PV power generation system   small power wind power generation system  YSmart SmartMicroinverter optimized  design for modularization modular power generation systems  They can use with DC  power source such as the mainstream solar module such as 18V  24V and 36V  monocrystal and or Polycrystalline solar panels  small power wind generator as well as  battery for converting into alternating current which suit
6. able for feeding into utility grid   Product is stable and reliable as well as high conversion efficiency  It is best choice for PV  power generation systems and small power wind power generation systems    YSmart SmartMicroinverter can be easy placed and attached to the rack of solar panels   No need space for independent installation and low voltage DC wire of side of solar  panel connecting to Smart Microinverter can eliminate the risk of   high DC voltage  which cause of high power centralized inverter   s series string and or parallel connections   Distributed modularization design philosophy for YSmart SmartMicroinverter will ensure  the productiveness of the whole system will not affect by a single point of failure  Each  Smart Microinverter is individually connected to one PV module in your array  This  unique configuration means that an individual Maximum Peak Power Point Tracker   MPPT  controls each PV module  This ensures that the maximum power available from  each PV module is exported to the utility grid regardless of the performance of the other  PV modules in the array  That is  although individual PV modules in the array may be  affected by shading  soiling  orientation  or PV module mismatch  the Smart  Microinverter ensures top performance for its associated PV module  The result is  maximum energy production from your PV system and gets return on investment in less    time     Advantages of YSmart SmartMicroinverter    1  Unique circuit design  choice of i
7. d   IS Lez es E  Fuses Air Intake AC Output Socket AC    Attach the Smart Microinverter to the racking or fix onto the wall        2   Fixed Screw  Grid Tie Inverter  O   hb AC  3  Properly connect the positive and negative of solar panel and Smart    Microinverter           Anonn  We    d r         JJ     Gomer        BLOCK  ae  VU   q     a   o  K A          4  AC power cable connects with Smart Microinverter and residential power    grid which refers to low voltage civilian single phase power grid     Connecting with family grid                   Power Cord    5  Switch on power grid after check for input and output connections are  correct and then switch on the Smart Microinverter  Red green LED lights up  first  and red LED lights off follow on and green LED lights on and flash fast   next LED flash slowly which indicates that Smart Microinverter is in  processing of MPPT operation for tracking down the Maximum power point  from solar module  Finally  green LED last lights on and indicates that  maximum power point lock in  Smart Micro inverter proper functioning and    output steady     Solar Panel             Status Indications of LED    AC frequency display  50Hz     LOW HIGH    60Hz AC voltage Range  230VAC display    125VAC ST    FAULT   Adjustment    AC voltage display Power output display       1  Red LED   1 1 Red FAULT LED indicator lights up under any conditions as listed below    a  Low voltage protection DC input voltage lower than Min  input voltage of inve
8. mport industrial electronic components  higher  efficiency  more stable performance    2  Creative MPPT technology  efficiency more than 99   faster reaction  more sensitive  of reaction and more reliable of Maximum power point locking    3  Parallel modular design  small volume  distributed installation  easy for system  configuration  flexible for combination  strong expansibility of system    4  Adopting high frequency isolation transformer type  high efficiency  high security   5  Perfect electrical protection function    6  Aluminum alloy housing  not rust  heat resisting and cold resistant as well as  anti corrosion    7  Getting electronic circuit design  appearance design and other core technology  patents    8  Wide input voltage  15 60VDC   suit for different DC power supply     Important Safety Information   Read this First   This manual contains important instructions for use during installation and maintenance  of the YSmart SmartMicroinverter  To reduce the risk of electrical shock  and to ensure  the safe installation and operation of the YSmart SmartMicroinverter  the following safety  symbols appear throughout this document to indicate dangerous conditions and    important safety instructions     DANGER  This indicates a hazardous situation  which if not avoided  will    result in death or serious injury     be a safety hazard or cause equipment malfunction  Use extreme caution and    NOTE  This indicates information particularly important for optimal system 
9. roller 24V         Small Power Wind generator  Power Grad     fp  Feed into EA  Regodential Grid      i   So e w  i    _p  lt q Grid Tie Inverter  E  E Fl es   Ej   a G       zc  DC   a  AC Two way AC mater l g    Wied Generztor i    AGK Charge Controller    Inverter          3 work with battery you can use solar and wind to charge the battery and the  battery release the power to the grid through inverter    Solar Panel   ke Dap Tops    BER Feed into  HHH Battery Inverter Residential Grid  HOEP       Power Grid H   o m           d   E  i       S d GA  CHE Lk   DI a Grid Tie Inverter   T   E  F KE    d   Lach he  Small Power   oc Feat Ir          y E a    Sa   Wind generator V       j  me   x E   r 1     Ter may AC Meter p lt     I        Wind Generator   i    AC OC Charge Controller       15    
10. rters    b  Over voltage protection DC input voltage higher than Max  input voltage of inverters     c  Over temperature protection  inverters will be shut down for power output when the    temperature of body of inverters higher than 65 75  C   And inverter will be automatically    restart up when the temperature of body of the inverter down to 40 50  C     d  Power grid fault protection  when 110VAC or 220VAC grid power outage and or tripped    el  Islanding protection  inverter will be automatically shut down for power output when discc    power grid   1 2 Red LOW indicator  DC input voltage lower than 37VDC  1 3 Red High indicator  DC input voltage higher than 37VDC  1 4 Red Power LED indicator  Follow the inverter power output size flow flashing    quickly or slowly     2  Blue ST LED   a  Blue LED flash  adjusting for power output  MPPT operating for tracking   b  Blue LED long light  indicates inverter locking in Max  output power operation status   3  Green LED   c  AC voltage display  Display the power grid voltage   125VAC  90VAC 140VAC    230VAC  190VAC 260VAC  d  AC frequency display  Display the power grid frequency     4  Please note that above operations only run at grid connected status     Troubleshooting a non operating Smart microinverter    System halted and  or without power output    1     2  3   4    Check if switch of Smart Microinverter is turn on or not    Check if the DC connections to Smart Microinverter are correct or not    Check if any reverse D
11. s can do the trouble  shooting of the Smart Microinverter system    A WARNING  Do not disconnect the microinverter from its PV module  when the inverter is still operating  Disconnect the inverter from the PV  module during running may damage the microinverter and bring   A electrical hazard to the person nearbv    WARNING  Disconnect the AC grid first before disconnecting the  inverter from the PV module    A WARNING  Do not attempt to repair the Smart Microinverter  This may  bring electrical hazard to the person and it will also void the  Microinverter warranty  If troubleshooting methods fail  please contact  YSmartcustomer support to return the Microinverter and initiate for  replacement process     Product Warranty Card  Invalid Duplicate    Customer Feedback     A    Purchase Channels and or  Sources    13       Date of Purchase    Date of Installation    Time of Using    Brief Fault Description    Improvement Suggestions    Telephone and or    Email    Date of finish Disposal  YSmartQC  Others       14    Connect method  1 Work with 72cell solar panel Vmp  35 37V Voc  44 46V     Solar Panel       KEE ri  KLEK        Hee Power Grid   C  cease a  eer Inverter        eee   Feed into BE oo  Cor C Gem E ffe      Residential Grid i j  m Fi      i  i Grid Tie inverter                         l    E   H g d       F   g   pa  at      D  I     Ac Two way AC Meter        2 Work with wind turbine if the wind trbine do not build in wind charge  controller need add wind charge cont
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
GERMAN TIGER - MRC  807-General-Manual_Jan-2012    Couleurs Bois  Harbor Freight Tools 40728 User's Manual  PRECISION TIG® 225  Sun StorEdge 3900 and 6900 Series 1.1 Installation Guide  取扱説明書 - ダイヤコジャパン  Montage- und Bedienungsanleitung Mounting and Operating  - SOLO Kleinmotoren GmbH    Copyright © All rights reserved. 