Home

EZ VAC/Splintvac Instructions

image

Contents

1. Selintvac Instructions for use SYNCA lt gt 1 800 667 9622 Synca Marketing Inc 337 Marion Le Gardeur QC Canada J5Z 4W8 Splintvac instructions V3 Caution U S Federal law restricts this device to sale by or on the order of dentist or dental technicians 2010 07 09 SPLINTVAC Instructions for use Thank you The ability to work quickly and precisely is indispensable in the realization of quality dentures and dental prosthetics With this in mind we wish to thank you for acquiring the SPLINTVAC SPLINTVAC is a simple and efficient device that will allow you significant time savings during denture fabrication while offering the best in esthetic results Built from a rigid frame and silicone membrane without latex SPLINTVAC is both durable and biocompatible This instruction guide will permit you to use your device safely to benefit from all its possibilities and ensure its longevity Description and Function SPLINTVAC is a vacuum forming device that operates at room temperature to adapt dental products to plaster models or directly onto dentures It consists of a vacuum forming chamber and a manual pump Forming occurs when a vacuum pulls a transparent silicone membrane over a dental product to contact and form onto a plaster model or a denture The product that that has been formed can then be polymerized through the transparent membrane Parts illustration and list A Aluminum vacuum forming chamber x1 B T
2. ith return of any unit Limitation of responsibility Except for where prohibited by law Synca Marketing Inc cannot be held responsible for any damage arising from use of product including direct indirect specific accidental or consequential under any circumstances including any guaranty contract negligence or responsibility The user is responsible to determine proper use of product and Synca Marketing Inc rejects any responsibility related to misuse of the unit or for any breakage due to not following this instruction guide Use only parts and accessories supplied by Synca Marketing Inc Synca Marketing Inc refutes any responsibility from usage of other accessories and parts Note Product for dental use only Keep away from children BH Consult the user manual
3. n the cover and the chamber Do not adjust scratch or sand the surfaces that join the cover to the chamber with cutting or abrasive tools to maintain the sealing capabilities of the SPLINTVAC Replace any silicone membranes that are punctured or torn Keep the pump clean and in working order Keep the valve tubing and connectors free of dirt by cleaning as necessary Troubleshooting Cause of problem the silicone membrane does not move The membrane is not coming into proper contact during pumping Ensure that both ends of the flexible tubing are fully inserted pump and value If necessary disconnect inspect and clean The membrane is coming into proper Air leak in system Ensure that the membrane has no folds between the cover and the contact but loses contact after a few chamber seconds after pumping Press down on the cover to improve contact with membrane If necessary remove the membrane and inspect all surface joints and membrane Remove any dirt Replace membrane if punctured or torn The valve was left open Close valve as soon as the desired vacuum has been attained pump is disconnected It should pull off without excessive force After use the membrane maintains The pump is still connected Disconnect the flexible tubing from the connection to let air into the contact when the valve is opened SPLINTVAC It is also possible to let the air in by removing the cover Accessories The following accessories are a
4. n the quick connector and pulling on the Flexible tubing F It should pull off without excessive force The SPLINTVAC may now be transported without risk of agitation of the beads g Wrap the flexible tubing F around the aluminum chamber A and attach with the Holding clip G h Bring the assembly to a light curing unit PRO CURE for example or to a hand held curing light Light cure the product as per manufacturer s instructions i After polymerization of the product open the vacuum valve D and remove cover C and silicone membrane B to access product Note Clean the different surfaces of the aluminum chamber and silicone membrane after each use In particular the silicone membrane must be clean on both surfaces as it will come in contact with products that are being formed and it must remain transparent to allow for future light curing processes The silicone membrane is a consumable part that is replaceable Its useful life varies with usage To avoid premature tears handle with care Do not apply excessive pressure when closing cover or use for forming products with sharp edges Maintenance and cleaning Clean with a mild soap and water solution or with alcohol Regularly clean the aluminum chamber and cover Remove traces of dental products with every use Properly clean the membrane with every use as it comes in contact with dental products To ensure the system is properly sealed remove any residue that may be stuck to the joint betwee
5. ransparent silicone forming membrane x3 C Aluminum vacuum forming chamber cover x1 D Open close vacuum valve with quick connector x1 E Vacuum pump with quick connector x1 F Flexible tubing with connector x1 G Holding clip and attachment for tubing x1 H Spacing beads 100 to 150 ml General Use The SPLINTVAC is particularly suited for shaping of FIBER FORCE pre impregnated splints however it will allow you to complete several other low temperature forming tasks using light and self curing dental products For proper results it is imperative to observe recommendations and follow instructions Indications SPLINTVAC is recommended for the shaping of FIBER FORCE pre impregnated splints during the fabrication of removable dentures temporary bridges It is particularly useful in the forming of FIBER FORCE meshes on a plaster model as it ensures an intimate contact between the meshand the model both before and during polymerization SPLINTVAC is also used for other FIBER FORCE pre impregnated splints when necessary to maintain contact to a model or removabk prosthesis Contraindications Do not place SPLINTVAC in an oven or in an environment of excessive heat This will cause burning and deterioration of the SPLINTVAC Do not use SPLINTVAC with liquid products or solvents that may release fumes Fumes may cause the pump to deteriorate Do not use SPLINTVAC with any product susceptible to deteriorate the silicone membrane or the aluminum vac
6. t the top of the beads are aligned with the functional limits of the plaster model SPLINTVAC usage SPLINTVAC works by creating a vacuum in the vacuum forming chamber A that will pull down the silicone membrane B A dental product that has been placed in the chamber will simultaneously be pulled down to form a tight contact with either a plaster model or a removable prosthesis a Place the product to be formed FIBER FORCE mesh for example on the plaster model b Center and place the silicone membrane B on the aluminum chamber A c Place the aluminum cover C over the membrane B and aluminum chamber A Be careful that the silicone membrane has no folds to prevent air leaks Exert light pressure on the aluminum cover C for a tight fit of the silicone membrane B ATTENTION Once closed do not agitate the assembly to prevent movement of the beads d Open the vacuum valve D and manually start the pump E The silicone membrane will stretch to come in contact with the product and press it onto the plaster model or dental prosthesis The vacuum is reached once pumping gets difficult A small click will be heard in the pump Ensure that there is no air leak If necessary exert pressure again on the aluminum cover C to press tightly against the silicone membrane B If an air pocket is visible smooth with a finger and the air pocket will resorb e Close the valve f Disconnect the Flexible Tubing F from the pump E by pulling back the flange o
7. uum chamber Precautions X Clean with alcohol only Do not use products that are susceptible to deteriorate the silicone membrane or the aluminum vacuum chamber X Do not use SPLINTVAC with shapes that are pointed or have jagged edges as this may rupture the silicone membrane X Do not modify scratch or sand surface joints between the chamber cover and the chamber with cutting or abrasive tools to maintain the SPLINTVAC seal X Burn Risk Certain light curing units may transmit significant heat to the SPLINTVAC Assembly and Use SPLINTVAC assembly and preparation Inspect the box upon receipt to ensure that no parts are missing and that no damage has occurred in transport If parts are missing immediately contact your vendor or service center l Push the Flexible tubing F into the connection on the valve D Ensure the tubing is pushed to the end of the connector Il Push the other end of the flexible tubing F into the vacuum pump connector Ensure the tubing is pushed to the end of the connector Il Pour part of the spacing beads H into the chamber A These beads will help evacuate air during the vacuuming process and will bring the plaster model to a height that minimizes stretching of the silicone membrane IV Place the plaster model into the spacing beads It should be placed so that the top of the model is 5 10 mm below the top of the aluminum chamber A Add or remove spacing beads as necessary The model should be set to tha
8. vailable for the SPLINTVAC 13003 SPLINTVAC unit 1 chamber 1 cover 1 valve 1 flexible tubing 1 holding clip 7 13004 1 SPLINTVAC vacuum pump 1 vacuum pump 1 quick connector 7 x Limited warranty Synca Marketing Inc warranties each new SPLINTVAC to be free of defects in materials and workmanship The SPLINTVAC unit is covered by a warranty for 1 year from purchase date with the exception of the silicone membrane which is a consumable item Breakage due to defective materials or hidden defects will be repaired free of charge during the warranty period The foregoing warranty constitutes the sole liability of Synca Marketing Inc and is in lieu of any other warranty of merchantability of fitness Synca Marketing Inc shall not be responsible for any incidental or consequential damages arising from use of product In case of warranty claim the complete system must be returned with all accessories transportation charges prepaid to Synca Marketing Inc with a copy of the original invoice When possible use original packaging Procedure in case of repair Repairs must be completed solely by Synca Marketing Inc or an authorized service center If problems cannot be solved with the troubleshooting guide contact your local distributor for the return procedure A clear description of the problem and the conditions surrounding the problem may help identify and resolve the problem Please provide this written information w

Download Pdf Manuals

image

Related Search

Related Contents

FlowclearTM  Owner`s Manual  SBS TEBOOKIP647Y mobile phone case  Cyclone User`s Manual  [福祉総務課]基準表(PDF形式:17363KB)  Novomatic 553 S et 803 S  ダウンロード - ボイスキャディ3  

Copyright © All rights reserved.