Home

MINICUBE OCD Checker MINICUBE Utility UM

image

Contents

1. User s Manual U18591EJ2V0UM 19 CHAPTER 4 OCD CHECK FOR MINICUBE2 AND V850 MICROCONTROLLER This section describes the method to check the connection between MINICUBE2 and the target system which uses a V850 microcontroller as the target device using the OCD Checker 4 1 20 Execution of OCD Check Be sure to terminate the debugger QBP and MINICUBE2 diagnostic tool before executing the OCD Checker The 78K0 OCD board and 10 pin target cable accessories of MINICUBE2 are not used Perform the connection check according to the following steps 1 to 6 1 2 3 MINICUBE2 setup e Power select switch Set the switch corresponding to the target system e Mode select switch Set to M2 e Target cable Connect the 16 pin target cable Connection and power application Connect MINICUBE2 to the target system in accordance with MINICUBE2 User s Manual U18371E and the turn on power to the target system Setting the OCD Checker Refer to 2 3 Explanation of Each Area e Emulator mode select area Select MINICUBE2 V850 e Target Device Connection area Device Select the target device to be connected from the drop down list If the target device name is not displayed specify the device file saving destination folder using the Device file folder button Port Select the mode for connection with target system from the drop down list e Clock select area Input the original main clock frequency in the Main
2. Check the connections between the host machine and the USB cable and the USB cable and the MINICUBE2 Turn all the power supplies off according to the procedures described in the user s manual MINICUBE2 is turned off by disconnecting the USB cable Turn all the power supplies on and then click the Test button If an error message is displayed even after taking these measures restart Windows on the host machine before turning all the power supplies on 2 The debugger has been started The debugger and the OCD Checker cannot be started simultaneously so terminate the debugger 3 The USB driver may not be operating normally Confirm the cable connection and the USB driver setup Re install the USB driver as necessary 4 The debugger may not be installed normally Re install the debugger Target Power 0 0V NG The power supply to the target system cannot be detected Confirm that the power for the target system is on Check the connection between the target system and MINICUBE2 Incorrect ID code The input ID code is incorrect Confirm the ID code written to the target device and re input the ID code 36 User s Manual U18591EJ2VOUM CHAPTER 6 OCD CHECK FOR MINICUBE2 AND 78K0R MICROCONTROLLER 2 2 Error message and action Log file write error The specified log file cannot be accessed Confirm that the folder path and file are write enabled Monitor Command xxH
3. Glock i Internal ROM Security fe socket internal M ID Code Sepak Log file C Temp IEOCDUTL log 10 54 10 Target Clock O OOMHz NG Target Power 49 OK MINICUBE 78KD 4000 C 441 11 Emulator Test End Log file Execution time gt tttmm ss Clock status NG error gt Target Clock 0 00MHz NG VDD status Target Power 4 9V OK Hardware version gt MINICUBE 78KO 4000 x xx xx Emulator Test End In this NG example the clock status 0 00MHz is detected as an error The clock frequency 0 00 MHz is detected This is because no oscillator is mounted in the CLK1 socket but socket is selected in the clock select area User s Manual U18591EJ2VOUM 41 CHAPTER 7 OCD CHECK FOR 78K0 MINICUBE 7 4 Action for Error The errors that may occur during self testing such as setting error and relevant actions for coping with the errors are listed below If an error other than below is displayed the cause may be a defect in 78KO MINICUBE If the same error is displayed even after the relevant action is implemented the cause may be a defect in the 78KO MINICUBE In such a case consult an NEC Electronics sales representative or distributor 1 2 Error message and action 1 Communication error There is no response from the target device gt Address 0x84 on chip debug emulator use enable flag is set to 0x00 disable use or the self check board and MINICUBE are not connected correctly Confirm the f
4. button This completes uninstalling the OCD Checker Users Manual U18591EJ2VOUM 51 lt R gt APPENDIX A REVISION HISTORY A 1 Major Revisions in This Edition CHAPTER 2 INSTALLATION AND STARTUP p 10 Addition of description in 2 1 1 Installation Addition of description in 2 1 2 Startup APPENDIX A REVISION HISTORY Addition of APPENDIX A REVISION HISTORY 52 User s Manual U18591EJ2VOUM MEMO User s Manual U18591EJ2VOUM 93 MEMO 54 User s Manual U18591EJ2VOUM MEMO User s Manual U18591EJ2VOUM 55 For further information please contact NEC Electronics Corporation 1753 Shimonumabe Nakahara ku Kawasaki Kanagawa 211 8668 Japan Tel 044 435 5111 http www necel com America NEC Electronics America Inc 2880 Scott Blvd Santa Clara CA 95050 2554 U S A Tel 408 588 6000 800 366 9782 http www am necel com Europe NEC Electronics Europe GmbH Arcadiastrasse 10 40472 D sseldorf Germany Tel 0211 65030 http www eu necel com Hanover Office Podbielskistrasse 166 B 30177 Hannover Tel 0 511 33 40 2 0 Munich Office Werner Eckert Strasse 9 81829 M nchen Tel 0 89 92 10 03 0 Stuttgart Office Industriestrasse 3 70565 Stuttgart Tel 0 711 99 01 0 0 United Kingdom Branch Cygnus House Sunrise Parkway Linford Wood Milton Keynes MK14 6NP U K Tel 01908 691 133 Succursale Francaise 9 rue Paul Dautier B P 52 78142 Velizy Villacoublay C dex F
5. it is also assumed that the readers have sufficient knowledge of Windows For the usage and terminology of Windows 98 Windows Me Windows 2000 and Windows XP refer to each Windows manual The mark lt R gt shows major revised points The revised points can be easily searched by copying an lt R gt in the PDF file and specifying it in the Find what field To understand the overall operation of the MINICUBE OCD Checker Read this manual according to the CONTENTS Note Footnote for item marked with Note in the text Caution Information requiring particular attention Remark Supplementary information Numeric representation Binary xxxx or xxxxB Decimal XXxx Hexadecimal xxxxH 2E Indicates an arbitrary message or item on the screen E indicates the name of a button command dailog box or area User s Manual U18591EJ2VOUM Terminology Related Documents The meanings of the terms used in this manual are as follows Emulator General name that means MINICUBE2 78K0 MINICUBE and 78K0S MINICUBE MINICUBE2 Indicates QB MINI2 an on chip debug emulator with programming function 78K0 MINICUBE Indicates 78KO on chip debug emulator QB 78KOMINI 78K0S MINICUBE Indicates 78K0S Kx1 in circuit emulator QB 78KOSKX1MINI Debugger Indicates NEC Electronics integrated debugger ID78K0 QB ID78KOS QB ID78KOR QB or ID850QB QBP Indicates the QB Programmer GUI software used for flash programming Device fi
6. Device Connection 78K0S MINIGUBE Device 7 Port_ loc Internal Bier security fe socket Internal Iz Il i KEEN Te mpYIEQCDUTL loe 44 User s Manual U18591EJ2VOUM CHAPTER 8 OCD CHECK FOR 78K0S MINICUBE 4 When all of the tests are complete the result dialog box is displayed as shown below The contents displayed in the log view window are saved in the log file If an NG is displayed 8 3 Error Output and 8 4 Action for Error Click the OK button OGD Checker Mode af the emulator Target Device Connection EOS MINICUBE Device F Port r 4 r Clock al ROM B socket IX TempXIEOGD 08 53 21 Target Glock 10 00MHz OK Target Power POG Target Reset HIGH OCD Control Code 41 01 MINICUBE 8k0s5 2000 B El Ola Control Board 0007 01 00 LO Board O100 00 03 01 01 ALL OK Emulator Test End 5 Click the Exit button _ OGD Checker Mode af the emulator Target Device Connection J8K S MINIGUBE Device F Port Glock i Internal ROM Security socket f internal Log file C Temp IEOCDUTL log Target Power POG Target Reset HIGH OCD Control Gode 41 01 MIMICLIBE 8K05 2000 B El Ola Control Board 0007 01 00 0100 00 03 01 01 Users Manual U18591EJ2VOUM 45 8 2 46 CHAPTER 8 OCD CHECK FOR 78K0S MINICUBE Format of Log File The following shows an example of the log file when
7. Error Communication between the target device and MINICUBE2 has failed The cause may be a problem in the electrical specifications of the cable or the target system or the USB driver may not be operating normally Confirm the connection and restart Windows on the host machine Emulator Command xxH Error Communication between the host machine and MINICUBE2 has failed 1 Check the connections between the host machine and the USB cable and the USB cable and the MINICUBE2 2 Turn all the power supplies off according to the procedures described in the user s manual MINICUBE2 is turned off by disconnecting the USB cable Turn all the power supplies on and then click the Test button If an error message is displayed even after taking these measures restart Windows on the host machine before turning all the power supplies on 3 Check if the target device name matches the name specified in the Device drop down list in the Target Device Connection area Program Download NG An error occurred while writing to the flash memory 1 Check if the items specified in the Target Device Connection area and clock select area satisfy the target device specifications 2 Check the connections between the target device and MINICUBE2 3 Check the power supply to the target system 4 The cause may be the security flag setting so clear the security flag setting via the flash memory programmer 5 The target de
8. NG The clock mounted in the CLK1 socket may not be operating Confirm the clock oscillation or remove the clock mounted in the CLK1 socket in the 78K0 OCD board and use the internal clock Select Socket Clock The clock mounted in the CLK1 socket is not selected Select socket for the clock setting or remove the clock mounted in the CLK1 socket and select internal Driver open error 1 There is no response from MINICUBE2 Check the connections between the host machine and the USB cable and the USB cable and the MINICUBE2 Turn all the power supplies off according to the procedures described in the user s manual MINICUBE2 is turned off by disconnecting the USB cable Turn all the power supplies on and then click the Test button If an error message is displayed even after taking these measures restart Windows on the host machine before turning all the power supplies on 2 The debugger has been started The debugger and the OCD Checker cannot be started simultaneously so terminate the debugger 3 The USB driver may not be operating normally Confirm the cable connection and the USB driver setup Re install the USB driver as necessary 4 The debugger may not be installed normally Re install the debugger User s Manual U18591EJ2VOUM CHAPTER 3 OCD CHECK FOR MINICUBE2 AND 78K0 MICROCONTROLLER 2 2 Error message and action Incorrect ID code The input
9. Yeoksam Dong Kangnam Ku Seoul 135 080 Korea Tel 02 558 3737 http www kr necel com G0706
10. but Renesas Electronics does not warrant that such information is error free Renesas Electronics assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information included herein Renesas Electronics products are classified according to the following three quality grades Standard High Quality and Specific The recommended applications for each Renesas Electronics product depends on the product s quality grade as indicated below You must check the quality grade of each Renesas Electronics product before using it in a particular application You may not use any Renesas Electronics product for any application categorized as Specific without the prior written consent of Renesas Electronics Further you may not use any Renesas Electronics product for any application for which it is not intended without the prior written consent of Renesas Electronics Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas Electronics product is Standard unless otherwise expressly specified in a Renesas Electronics data sheets or data books etc Standard Computers of
11. e Internal ROM Security setting area Input the ID code e Log file button Specify the log file name and the location for saving the log file 4 bd Click the Test button If an error occurs during checking refer to 3 3 Error Output and 3 4 Action for Error 4 OCD Checker Mode of the emulato Target Device Connection MINICLIBE 78K0 Device Port_L Gloc Internal kati Security f socket C internal l ID Code EAEE E C Te mp IEOCDUTL loz 14 User s Manual U18591EJ2VOUM CHAPTER 3 OCD CHECK FOR MINICUBE2 AND 78K0 MICROCONTROLLER 5 When all of the tests are complete the result dialog box is displayed as shown below The contents displayed in the log view window are saved in the log file If an NG is displayed refer to 3 3 Error Output and 3 4 Action for Error Click the OK button 7 OGD Checker Mode of the emulator 71 Target Device Connection y MIMIGLUBE2 TAKO Device Fort y Internal ROM Security socket C interna Men OSC iHe ieocouTt X ss C tmp MOB2UT arget Glock 20 00MHz OK Target Power 5 14 OK Target Reset HIGH OCD Gontral Code 4 00 MINICUBE 4100 4 4 01 Program Download OK Run Test OK Flash Erase OK ALL OK Emulator Test End 6 Click the Exit button En OCD Checker E Exit Mode af the emulator Target Device Connection 1 IMINICUBES 7ek0 Internal ROM E s
12. self check board may be damaged so exchange the target device Break Timeout ERROR SP Break Test ERROR Execute Break Test1 ERROR SFR Access Break Test ERROR Read Access Break Test1 ERROR Read Access Break Test2 ERROR Write Access Break Test1 ERROR Write Access Break Test2 ERROR Step Break Test ERROR Execute Break Test2 The target device on the self check board may be damaged so exchange the target device User s Manual U18591EJ2V0UM 43 CHAPTER 8 OCD CHECK FOR 78K0S MINICUBE This section describes the method to perform a simple test based on checking the connection between the QB 78KOSMINI and QB 78K0SKX1 DA of the 78K0S MINICUBE using the OCD Checker 8 1 Execution of OCD Check Be sure to terminate the debugger before executing the OCD Checker 1 Connection and power application Connect the 78K0S MINICUBE with QB 78KOSMINI and QB 78KOSKX1 DA connected or 78K0S MINICUBE to the target system in accordance with QB 78K0SKX1MINI User s Manual U17272E 2 Setting the OCD Checker Refer to 2 3 Explanation of Each Area e Emulator mode select area Select 78KOS MINICUBE gt e Clock select area Select internal or socket e Log file button Specify the log file name and the location for saving the log file 3 Click the Test button If an error occurs during checking refer to 8 3 Error Output and 8 4 Action for Error OCD Checker E mE Exit 2 Mode of the emulator arget
13. the Target Device Connection area and clock select area satisfy the target device specifications 2 Check the connections between the target device and MINICUBE2 3 Check the power supply to the target system 4 The cause may be the security flag setting so clear the security flag setting via the flash memory programmer 5 The target device may be damaged so exchange the target device 6 Check the MINICUBE2 settings 7 Check the circuit for connecting MINICUBE2 Break Timeout ERROR Execute Break Test1 ERROR Read Access Break Test ERROR Write Access Break Test ERROR Execute Break Test2 The target device may be damaged so exchange the target device Target Power 0 0V NG The power supply to the target system cannot be detected Confirm that the power for the target system is on gt Check the connection between the target system and MINICUBE2 Use the firmware version Vx xx or later Update MINICUBE2 firmware to Vx xx or later Users Manual U18591EJ2VOUM 25 CHAPTER 5 OCD CHECK FOR MINICUBE2 AND 78K0S MICROCONTROLLER This section describes the method to check the connection between MINICUBE2 and the target system which uses a 78K0S microcontroller as the target device using the OCD Checker 9 1 26 Execution of OCD Check Be sure to terminate the debugger QBP and MINICUBE2 diagnostic tool before executing the OCD Checker The 78K0 OCD board and 10 pin target cable accessories of MINIC
14. the check results show OK statuses e Execution time e Clock status e Vpp status e Reset status Execution time tt mm ss Clock status Target Clock 10 00MHz OK VDD status Target Power POC Reset status Target Reset HIGH OCD Control Code Vx xx Hardware MINICUBE 78KOS 2000 x xx xx version Control Board 0001 xx xx I O Board 0100 00 03 xx xx Check result ALL OK Emulator Test End The time when checking was started by clicking the Test button Frequency of the selected clock ON Power supply to the QB 78KOSKX1 DA and target system are on POC Power supply to the QB 78KOSKX1 DA is on and power supply to the target system is off OFF Power supply to the QB 78KOSKX1 DA is off NG RESET pin status HIGH Reset signal input from the target system is HIGH LOW Reset signal input from the target system is LOW e Hardware version Version of each hardware Remark The version of the 78KOS MINICUBE can be checked on the following NEC Electronics websites For the latest version consult an NEC Electronics sales representative or distributor Japanese version http www necel com micro ods jpn index html English version http www necel com micro ods eng index html See Version up service gt MINICUBE2_Software User s Manual U18591EJ2VOUM CHAPTER 8 OCD CHECK FOR 78K0S MINICUBE 8 3 Error Output The following describes the operation and display example when an NG is displayed as a result of 8 1
15. txt readme e txt 4 Install MINICUBE Utilities Vxxx main unit as follows e f the OS is Japanese Windows execute setup exe in the MINICUBE Utilities VxxxMapaneseWDISK1 folder and install the software according to the installer instructions e f the OS is not Japanese Windows execute setup exe in the MINICUBE_Utilities_Vxxx English DISK1 folder and install the software according to the installer instructions Caution Specify C Program Files NEC Electronics Tools as an installation destination folder Remarks 1 The MINICUBE OCD Checker and MINICUBE2 diagnostic tool can be installed by installing MINICUBE Utilities Vxxx 2 GHS Green Hills Software Inc IAR IAR Systems AB 2 2 2 Startup e Click the Start menu of Windows point to Programs NEC Electronics Tools Latest Version and then click MINICUBE Utilities Vx xx OCD Checker Caution f the debugger QBP or MINICUBE2 diagnostic tool is running terminate it before starting the OCD Checker Users Manual U18591EJ2VOUM 11 CHAPTER 2 INSTALLATION AND STARTUP 2 3 Explanation of Each Area When the OCD Checker is started the following window appears 11 3 1 4 2 5 10 OCD Checker gt AA Device file folder Program Files NEC Electrgnics Tool D EV 6 Mode of the emulator Target Device Connection MINISUBE 78KDR Device UPDOVGFITGZ AD Port TOOLD TOOLI Glock gt Interp amp l ROM Security sock E Log file CXTe mp IEQC
16. 0 2 2 When Tools Manufactured by Partner Companies GHS and IAR are Used 11 22 SaNa O sar oiu ee conacs ns ind tic e pt eos Cua ade ccc cete fac eb aa cea 11 22 OAND so demde I ID EQ M I Ei LEA 11 2 9 Explanallon or Each Area o UD LIP o newt ai DD LIBRI oO 12 CHAPTER 3 OCD CHECK FOR MINICUBE2 AND 78K0 MICROCONTROLLER 14 3 1 Execution oT OC DiC MG Gi tenias 14 SZ An epe IgE c eeu tu eos evo d Ode ead eae v raii 16 9 9 ELIANE cana A UE EL D E MU EU 17 24 ActUon TOF ENO 1 obe orae a etes ir aede Eoo I LE o o d la DUE 18 CHAPTER 4 OCD CHECK FOR MINICUBE2 AND V850 MICROCONTROLLER 20 4 1 EXecution of OCD CHECK dee r Oorr e eeni 20 MEM logie ee 22 43S Eror QUIE e e a da onesie ee tials 23 44 O 24 CHAPTER 5 OCD CHECK FOR MINICUBE2 AND 78K0S MICROCONTROLLER 26 5 1 Execution or OCD Ch6CcK iiie dicen LO eur 26 Oz Format of Log File rea eei EE Eee eo cR Re EOM bees e SERIO IDEEN ERU CLER 28 Jo ENOO oo oo euo tette stet mctu LE MM IM EMI LUS 29 94 ACTION TON ENVOR PE 30 CHAPTER 6 OCD CHECK FOR MINICUBE2 AND 78KOR MICROCONTROLLER 32 6 1 Execution of OCD Checkonuacina e ia ee ee 32 62 Formator Log Pile eee eei iaa a are ASA 34 63 o OU AA eM Mou eu LEM AL ME I LI DM LM M EAS 35 64 Acton Tfor EO enm Md 36 CHAPTER 7 OCD CHECK FOR 78K0 MINICUBE ococconcccconcccconccconcnccnnn
17. DUTL log 1 Emulator mode select area Select from the drop down list the emulator mode for which target connection check is to be performed 2 Target Device Connection area If MINICUBE2 V850 MINICUBE2 78K0S or MINICUBE2 78KOR is selected for the emulator mode specify from the drop down list the device file for the target device and the mode for connection with the target system This menu is unavailable if an item other than MINICUBE2 V850 MINICUBE2 78K0S or MINICUBE2 78KOR is selected e Device Select from the drop down list the target device to be connected If the target device device file is not displayed in the list specify the folder where the device file is saved using the 3 Device file folder button in the above window e Port Select the mode for connection with MINICUBE2 and target system from the drop down list available only when MINICUBE2 V850 or MINICUBE2 78KOR is selected 3 Device file folder button This button is used for searching the folder where the device file is saved to define the device file to be connected when MINICUBE2 V850 MINICUBE2 78K0S or MINICUBE2 78KOR is selected When the device file has been installed using the device file installer DFINDT the saved folder is automatically specified 12 User s Manual U18591EJ2VOUM 4 5 6 7 8 9 CHAPTER 2 INSTALLATION AND STARTUP Clock select area Select with t
18. E2 to the target system in accordance with MINICUBE2 User s Manual U18371E and the turn on power to the target system Setting the OCD Checker Refer to 2 3 Explanation of Each Area e Emulator mode select area Select MINICUBE2 78KOR e Target Device Connection area Device Select the target device to be connected from the drop down list If the target device name is not displayed specify the device file saving destination folder using the Device file folder button Port Select the mode for connection with target system from the drop down list e Clock select area Input the original main clock frequency in the Main OSC MHz text box e Internal ROM Security setting area Input the ID code e Log file button Specify the log file name and the location for saving the log file User s Manual U18591EJ2VOUM CHAPTER 6 OCD CHECK FOR MINICUBE2 AND 78K0R MICROCONTROLLER 4 Click the Test button If an error occurs during checking refer to 6 3 Error Output and 6 4 Action for Error 4 OGD Checker gt LT AES EE Device file folder OxProeram PAes HEG Electronics Toalz amp DEV Made of the emulator Target Device Connection MIMIGUBE2 78KOR Device ubp BFT168 A0 Port TOOLO TOOLT T infernal ROM Security i Cloc C Test internal ID Code eio oor O Te mpYIEQCDUTL log 5 When all of the tests are complete the result dialog box is displayed as shown below The cont
19. Execution of OCD Check The message just indicates NG but there are various causes 1 The result is displayed in the dialog box Click the OK button IEOCDUTL 1 2 The contents displayed in the log view window are saved in the log file Log view window Er OGD Checker Mode of the emulator Target Device Connection Device Port r Glock Internal ROM Security fe socket internal Log file CX TempiIEOGCDLITL Iog 11 11 08 Target Glock 10 00MH2 OK Target Power OFF MINICUBE 8K05 2000 B El Ma 00071 01 00 Emulator Test End Log file Execution time tt mm ss Clock status Target Clock 10 00MHz OK VDD status Target Power OFF Hardware MINICUBE 78KOS 2000 x xx xx version Control Board 0001 xx xx Emulator Test End In this NG example the error Target Power OFF is detected Shutdown of the power supplied to the QB 78KOSKX1 DA is detected This is because the check is performed without turning on the power to the QB 78KOSKX1 DA User s Manual U18591EJ2VOUM 47 CHAPTER 8 OCD CHECK FOR 78K0S MINICUBE 8 4 Action for Error The errors that may occur during self testing such as setting error and relevant actions for coping with the errors are listed below If an error other than below is displayed the cause may be a defect in the 78K0S MINICUBE If the same error is displayed even after the relevant action is implemented the cause may be a defect i
20. ID code is incorrect Confirm the ID code written to the target device and re input the ID code Log file write error The specified log file cannot be accessed Confirm that the folder path and file are write enabled Test Rom Command xxH Error Monitor Command xxH Error Communication between the target device and MINICUBE2 has failed The cause may be a problem in the electrical specifications of the cable or the target system or the USB driver may not be operating normally Confirm the connection and restart Windows on the host machine Write Memory Read Memory Data verify error The internal RAM cannot be accessed The target device may be damaged Exchange the target device _ Flash Env Error Flash Get Info Error Flash Block Blank Check Error Flash Block Erase Error Flash Word Write Error Flash Block Verify Error Flash Word Read Error Data Verify Error An error occurred while writing to the flash memory gt The cause may be the security flag setting so clear the security flag setting via the QBP The target device may be damaged so exchange the target device Break Timeout ERROR SP Break Test ERROR Execute Break Test1 ERROR SFR Access Break Test ERROR Read Access Break Test1 ERROR Read Access Break Test2 ERROR Write Access Break Test1 ERROR Write Access Break Test2 ERROR Step Break Test ERROR Execute Break Test2 The target device may be damaged so exchange the target device
21. K0 vaso 78KoS 78KOR MINICUBE MINICUBE Status of main clock o S O eee Status of target power supply EX payo papa py Ease ita morem Remark 1 Available blank Unavailable 2 For the 78K0S MINICUBE the system clock status target power supply status RESET pin status and hardware version indication are checked based on connection check of the QB 78KOSMINI and QB 78K0SKX1 DA both are components of the 78K0S MINICUBE 8 User s Manual U18591EJ2VOUM CHAPTER 1 OVERVIEW 1 3 Notes Before Using OCD Checker Chapters 1 and 2 present an overview and basic specifications of the OCD Checker and the following sections provide separate description for the target device and the emulator to be used To utilize this manual effectively refer to the following table and see the relevant section for your target device and purpose of use 78K0 MINICUBE2 CHAPTER 3 OCD CHECK FOR MINICUBE2 AND 78K0 MICROCONTROLLER V850 CHAPTER 4 OCD CHECK FOR MINICUBE2 AND V850 MICROCONTROLLER 78K0S CHAPTER 5 OCD CHECK FOR MINICUBE2 AND 78K0S MICROCONTROLLER 78KOR CHAPTER 6 OCD CHECK FOR MINICUBE2 AND 78KOR MICROCONTROLLER 78K0 78K0 MINICUBE CHAPTER 7 OCD CHECK FOR 78K0 MINICUBE 78K0S 78K0S MINICUBE CHAPTER 8 OCD CHECK FOR 78K0S MINICUBE User s Manual U18591EJ2V0UM 9 CHAPTER 2 INSTALLATION AND STARTUP This section explains how to install and start the OCD Checker 2 1 When NEC Electronics Tool Is Used 2 1 1 Installation R e Select t
22. OSC MHz text box e Internal ROM Security setting area Input the ID code e Log file button Specify the log file name and the location for saving the log file User s Manual U18591EJ2VOUM CHAPTER 4 OCD CHECK FOR MINICUBE2 AND V850 MICROCONTROLLER 4 Click the Test button If an error occurs during checking refer to 4 3 Error Output and 4 4 Action for Error 4 Er OGD Checker LO SI EA Device file folder E we EC Electronics Toole DEW Mode of the emulator r Target Device Connection MINICUBE W850 a Device uRDTOFS732 Fort CSIBE Glock T Internal ROM Security ES Test v ID Code Poo Main OSC MHz 50 Cx TempsEOCDUTL log 5 When all of the tests are complete the result dialog box is displayed as shown below The contents displayed in the log view window are saved in the log file If an NG is displayed refer to 4 3 Error Output and 4 4 Action for Error Click the OK button OGD Checker Device file falder Program Files NEC Electronics Toole DEV Es Mode af the emulator Target Device Connection MINICUBE VSO Y Device luPD70F3732 Port OSIBO T 5 Clock T Internal ROM Security E socket e internal de kkokokokokckololololololololo Ao Main OSC MH SU LOE E CX TemprIEOCGD 09 49 19 Target Power 3 2 V Target Reset HIGH MINICUBE 4100 4 4 01 Program Download OK Run Test OK Flash Erase OF ALL OK Emulator Test End Us
23. OUM 29 CHAPTER 5 OCD CHECK FOR MINICUBE2 AND 78K0S MICROCONTROLLER Log file Execution time tt mm ss Reset status OK Target Reset HIGH Hardware version MINICUBE2 4100 x xx xx Error indication Program Download NG Emulator Test End In this NG example the error Program Download is detected An error during flash memory programming is detected The cause is an error in pin connection on the board for connecting MINICUBE2 on the target system pin 5 SO is shorted with GND 5 4 Action for Error The errors that may occur during self testing Such as setting error and relevant actions for coping with the errors are listed below If an error other than below is displayed the cause may be a defect in MINICUBE2 If the same error is displayed even after the relevant action is implemented the cause may be a defect in MINICUBE2 In such a case consult an NEC Electronics sales representative or distributor 1 2 Error message and action 1 There is no response from MINICUBE2 Check the connections between the host machine and the USB cable and the USB cable and the MINICUBE2 Turn all the power supplies off according to the procedures described in the user s manual MINICUBE2 is Turn all the power supplies on and then click the Test button If an error message is displayed even after taking these measures restart Windows on the host machine before turning all the power supplies on turned off by disconn
24. Test End e Execution time The time when checking was started by clicking the Test button e Vpp status Voo value that is applied to the target device e Reset status RESET pin status HIGH Reset signal input from the target system is HIGH LOW Reset signal input from the target system is LOW e Hardware version Version of each hardware e Check result Program Download D verification result of downloading to flash memory in the target device Run Test Result of executing and stopping the program Flash Erase Erasure result of flash memory in the target device 34 User s Manual U18591EJ2V0UM CHAPTER 6 OCD CHECK FOR MINICUBE2 AND 78K0R MICROCONTROLLER Remark The version of MINICUBE2 can also be checked with the MINICUBE2 diagnostic tool debugger and QBP The latest version of MINICUBE2 firmware can be checked on the following NEC Electronics websites Japanese version http www necel com micro ods jpn index html English version http www necel com micro ods eng index html See Version up service gt MINICUBE2_ Software 6 3 Error Output The following describes the operation and display example when an NG is displayed as a result of 6 1 Execution of OCD Check The message just indicates NG but there are various causes 1 The result is displayed in the dialog box Click the OK button 2 The contents displayed in the log view window are saved in the log file Log view window Er OCD Checker De
25. To our customers Old Company Name in Catalogs and Other Documents On April 1 2010 NEC Electronics Corporation merged with Renesas Technology Corporation and Renesas Electronics Corporation took over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electronics website http www renesas com April 1 2010 Renesas Electronics Corporation Issued by Renesas Electronics Corporation http www renesas com Send any inquiries to http www renesas com inquiry 24 NC S AS 8 10 11 12 Notice All information included in this document is current as of the date this document is issued Such information however is subject to change without any prior notice Before purchasing or using any Renesas Electronics products listed herein please confirm the latest product information with a Renesas Electronics sales office Also please pay regular and careful attention to additional and different information to be disclosed by Renesas Electronics such as that disclosed through our website Renesas Electronics does not assume any liability for infringement of patents copyrights or other intellectual property rights of third parties by or arising from the use of Renesas Electronics products or technical information described in this document No license express implied or otherwise is
26. UBE2 are not used Perform the connection check according to the following steps 1 to 6 1 2 3 MINICUBE2 setup e Power select switch Set the switch corresponding to the target system e Mode select switch Set to M2 e Target cable Connect the 16 pin target cable Connection and power application Connect MINICUBE2 to the target system in accordance with MINICUBE2 User s Manual U18371E and the turn on power to the target system Setting the OCD Checker Refer to 2 3 Explanation of Each Area e Emulator mode select area Select MINICUBE2 78K0S e Target Device Connection area Device Select the target device to be connected from the drop down list If the target device name is not displayed specify the device file saving destination folder using the Device file folder button e Log file button Specify the log file name and the location for saving the log file User s Manual U18591EJ2VOUM CHAPTER 5 OCD CHECK FOR MINICUBE2 AND 78K0S MICROCONTROLLER 4 Click the Test button If an error occurs during checking refer to 5 3 Error Output and 5 4 Action for Error 4 RE OCD Checker E Device file folder DXNECTaols32X DEV Exit Mode of the emulator r Target Device Connection MINICUBE 78K0S Device uPD78F9234 Port Glock Interriat eL ecur ty i C Temp YlIEQGDUTL log 5 When all of the tests are complete the result dialog box is displayed as shown
27. all the USB driver as necessary 4 The debugger may not be installed normally Re install the debugger Incorrect ID code The input ID code is incorrect Confirm the ID code written to the target device and re input the ID code Log file write error The specified log file cannot be accessed Confirm that the folder path and file are write enabled 24 User s Manual U18591EJ2VOUM CHAPTER 4 OCD CHECK FOR MINICUBE2 AND V850 MICROCONTROLLER 2 2 Communication between the target device and MINICUBE2 has failed gt The cause may be a problem in the electrical specifications of the cable or the target system or the USB driver may not be operating normally Confirm the connection and restart Windows on the host machine Emulator Command xxH Error Communication between the host machine and MINICUBE2 has failed 1 Check the connections between the host machine and the USB cable and the USB cable and the MINICUBE2 2 Turn all the power supplies off according to the procedures described in the user s manual MINICUBE2 is turned off by disconnecting the USB cable Turn all the power supplies on and then click the Test button If an error message is displayed even after taking these measures restart Windows on the host machine i before turning all the power supplies on T Program Download NG An error occurred while writing to the flash memory 1 Check if the items specified in
28. below The contents displayed in the log view window are saved in the log file If an NG is displayed refer to 5 3 Error Output and 5 4 Action for Error Click the OK button OGD Checker Device file falder DANECTooles2 DEV Exin Mode af the emulator Target Device Connection MIMIGUBE2 78K05 Device uPD78F9234 Port r 5 r Glock mim ROM e fea socket internal Main oScti HRS E IX TempXIEOGD 10 04 01 Target Reset HIGH MINICUBE 4100 4 vr Program Download OK Run Test OF Flash Erase OK ALL OK Emulator Test End User s Manual U18591EJ2VOUM 27 CHAPTER 5 OCD CHECK FOR MINICUBE2 AND 78K0S MICROCONTROLLER 6 Click the Exit button Er OCD Checker Device file folder DANECTools32 DEV Exit Mode of the emulator Target Device Connection Device juPD7SFS234 Port a Internal ROM Security LL OK Emulator Test End 5 2 Format of Log File The following shows an example of the log file when the check results show OK statuses Execution time tt mm ss Reset status Target Reset HIGH Hardware version MINICUBE2 4100 x xx xx Program Download OK Run Test OK Flash Erase OK ALL OK Emulator Test End Check result e Execution time The time when checking was started by clicking the Test button e Reset status RESET pin status HIGH Reset signal input from the target system is HIGH LOW Reset signal input from the target system i
29. cconnncnnnnarononaronannrnnnnrennnnrnonanenas 38 7 1 Execution of OCD Check a Ai ds 38 EZ Formato bog File 555 oi recien a 40 7 3 EMOFF QOUIDUL 54i in is del E 41 EE AACHON TO indo ee ECT E ed 43 6 User s Manual U18591EJ2VOUM CHAPTER 8 OCD CHECK FOR 78K0S MINICUBE ccccccoonococccccccooocccnnnccnnncnnonnnnnnccnnnnnnnnnnnccnnnnnnananannos 44 8 1 Execution or OCD Check la eee eUf 44 92 Format oPEog Flex una iia 46 9 39 Error OUILDUE ci oia 47 9 4 JAGUOD TOF Error ect conca EE EEEN 48 CHAPTER 9 OCD CHECKER VERSION INDICATION nene eene nennen nennen nennen nnn 50 CHAPTER 10 UNINSTALLATION sa ic asu s cde o aeu etd 51 APPENDIX A REVISION HISTORY coi id llena id 52 Al Major Revisions in This Ec o 52 User s Manual U18591EJ2VOUM 7 CHAPTER 1 OVERVIEW 1 1 MINICUBE OCD Checker MINICUBE OCD Checker hereinafter referred to as OCD Checker is a self check tool for simply detecting problems that may occur when an on chip debug emulator and target system are connected The OCD Checker checks if the communication circuits operate normally ccc Communication circuits must be mounted on the target system NEC Target device gt Serial communication communication MINICUBE2 Host machine Target system 1 2 Target Emulators and Items to Be Checked The following table lists the items that can be checked with the OCD Checker ae 78K0 78K0S Check Items 78
30. ded by NEC Electronics they must contact an NEC Electronics sales representative in advance to determine NEC Electronics willingness to support a given application Note 1 NEC Electronics as used in this statement means NEC Electronics Corporation and also includes its majority owned subsidiaries 2 NEC Electronics products means any product developed or manufactured by or for NEC Electronics as defined above M8E 02 11 1 User s Manual U18591EJ2VOUM 3 Target Readers Purpose Organization How to Read This Manual Conventions INTRODUCTION This manual is intended for users who use the MINICUBE OCD Checker when designing and developing a system using an NEC Electronics on chip flash memory microcontroller This manual is intended to give users an understanding of the basic specifications and correct use of the MINICUBE OCD Checker This manual includes the following sections e Overview e Installation and startup e OCD check for MINICUBE2 and 78K0 microcontroller e OCD check for MINICUBE2 and V850 microcontroller e OCD check for MINICUBE2 and 78KOS microcontroller e OCD check for MINICUBE2 and 78KOR microcontroller e OCD check for 78K0 MINICUBE e OCD check for 78K0S MINICUBE e OCD checker version indication e Uninstallation It is assumed that the readers of this manual have general knowledge of electricity logic circuits and microcontrollers In the explanations of the operation of the applications
31. der certain use conditions Further Renesas Electronics products are not subject to radiation resistance design Please be sure to implement safety measures to guard them against the possibility of physical injury and injury or damage caused by fire in the event of the failure of a Renesas Electronics product such as safety design for hardware and software including but not limited to redundancy fire control and malfunction prevention appropriate treatment for aging degradation or any other appropriate measures Because the evaluation of microcomputer software alone is very difficult please evaluate the safety of the final products or system manufactured by you Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each Renesas Electronics product Please use Renesas Electronics products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances including without limitation the EU RoHS Directive Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations This document may not be reproduced or duplicated in any form in whole or in part without prior written consent of Renesas Electronics Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas El
32. e MINICUBE2 diagnostic tool debugger and QBP The latest version of MINICUBE2 firmware can be checked on the following NEC Electronics websites Japanese version http www necel com micro ods jpn index html English version http www necel com micro ods eng index html See Version up service gt MINICUBE2_Software 16 User s Manual U18591EJ2VOUM CHAPTER 3 OCD CHECK FOR MINICUBE2 AND 78K0 MICROCONTROLLER 3 3 Error Output The following describes the operation and display example when an NG is displayed as a result of 3 1 Execution of OCD Check The message just indicates NG but there are various causes 1 The result is displayed in the dialog box Click the OK button IEOCDUTL X 1 2 The contents displayed in the log view window are saved in the log file Log view window L7 OCD Checker Mode of the emulator Target Device Connection MINIGUBE 78 d E Device Fort i Clock Internal ROM Security f socket internal 4 ID Code Sepak Log file CXtmpi MGBZLITL Iog 170879 Target Clock 20 00MH2 OK Monitor GommandtSFH Error Communication Error MINIGUBE 4100 4 W401 Emulator Test End Log file Execution time tt mm ss Clock status OK Target Clock 20 00MHz OK Emcrindiesion Monitor Command 3FH Error Communication Error Hardware version MINICUBE2 4100 x xx xx Emulator Test End In this NG example the monitor command 3FH error and communication error are o
33. ecting the USB cable 2 The debugger has been started The debugger and the OCD Checker cannot be started simultaneously so terminate the debugger 3 The USB driver may not be operating normally Confirm the cable connection and the USB driver setup Re install the USB driver as necessary 4 The debugger may not be installed normally gt Re install the debugger Log file write error The specified log file cannot be accessed Confirm that the folder path and file are write enabled Monitor Command xxH Error Communication between the target device and MINICUBE2 has failed The cause may be a problem in the electrical specifications of the cable or the target system or the USB driver may not be operating normally Confirm the connection and restart Windows on the host machine 30 User s Manual U18591EJ2VOUM CHAPTER 5 OCD CHECK FOR MINICUBE2 AND 78K0S MICROCONTROLLER 2 2 Emulator Command xxH Error Communication between the host machine and MINICUBE2 has failed 1 Check the connections between the host machine and the USB cable and the USB cable and the MINICUBE2 2 Turn all the power supplies off according to the procedures described in the user s manual MINICUBE2 is turned off by disconnecting the USB cable Turn all the power supplies on and then click the Test button If an error message is displayed even after taking these measures restart Windows on the host machine befo
34. ectronics products or if you have any other inquiries Note 1 Renesas Electronics as used in this document means Renesas Electronics Corporation and also includes its majority owned subsidiaries Note 2 Renesas Electronics product s means any product developed or manufactured by or for Renesas Electronics 424 NE S AS User s Manual MINICUBE OCD Checker MINICUBE Utility Target Devlopment Tool QB MINI2 QB 78KOMINI QB 8KO0SKX1MINI Document No U18591EJ2VOUMOO 2nd edition Date Published October 2008 NS NEC Electronics Corporation 2007 Printed in Japan MEMO 2 User s Manual U18591EJ2V0UM MINICUBE is a registered trademark of NEC Electronics Corporation in Japan and Germany Windows is either a registered trademark or a trademark of Microsoft Corporation in the United States and or other countries The names of other companies and products are the registered trademarks or trademarks of their companies e The information in this document is current as of October 2008 The information is subject to change without notice For actual design in refer to the latest publications of NEC Electronics data sheets or data books etc for the most up to date specifications of NEC Electronics products Not all products and or types are available in every country Please check with an NEC Electronics sales representative for availability and additional information e No part of this document may be copied or
35. ents displayed in the log view window are saved in the log file If an NG is displayed refer to 6 3 Error Output and 6 4 Action for Error Click the OK button OGD Checker Device file folder CXProgram Files NEC Electronics Toole DEW Exit Made of the emulator r Target Device Connection MINICUBE 78KOR Device uPD78F1166_A0 Port TOOLO TOOL1 y 5 lack 1 al ROM BRUN EE iocour Xj IX TempXIEOGD 10 13 59 Target Power 32V OK Target Reset HIGH MINIGUBE 4100 A 14 01 Program Download OK Run Test OK Flash Erase OF ALL OK Emulator Test End Users Manual U18591EJ2VOUM 33 CHAPTER 6 OCD CHECK FOR MINICUBE2 AND 78K0R MICROCONTROLLER 6 Click the Exit button Er OCD Checker Device file folder CXProgram Files NEG Electronics ToalzDEV Exit Mode of the emulator Target Device Connection Device juPDFSFIT66_A0 Port TOOLO TOOL Internal ROM Security m ID Code xoc poe ooo xoc EE k Log file CX TempiIEOCDLTL log Program Download Bun Test QK Flash Erase OK ALL OK Emulator Test End 6 2 Format of Log File The following shows an example of the log file when the check results show OK statuses Execution time tttmm ss VDD status Target Power 3 2V OK Reset status Target Reset HIGH Hardware version MINICUBE2 4100 x xx xx Program Download OK Check result J Run Test OK Flash Erase OK ALL OK Emulator
36. er e When using the ID850QB ID78K0 QB ID78KOS QB ID78KOR QB or QB Programmer Start OCD Checker by using either of the following methods e Click the Start menu of Windows point to Programs click MINICUBE Utilities Vx xx OCD Checker 5 11 NEC Electronics Tools Latest Version and then e Click the Start menu of Windows point to Programs NEC Tools32 and then click OCD Checker For an ID78K0 QB or ID78K0S QB earlier than V3 00 10 User s Manual U18591EJ2VOUM CHAPTER 2 INSTALLATION AND STARTUP Caution If the debugger QBP or MINICUBE2 diagnostic tool is running terminate it before starting the OCD Checker Remark When an ID78K0 QB or ID78K0S QB earlier than V3 00 a link file for startup is created in the NEC Tools32 and NEC Electronics Utilities folders 2 2 When Tools Manufactured by Partner Companies GHS and IAR are Used 2 2 1 Installation e Download MINICUBE Utilities MINICUBE Utilities Vxxx Izh from one of the following websites http www necel com micro ghs jpn exec execindex html Japanese version http www necel com micro ghs eng exec English version 1 Download MINICUBE Utilities Vxxx Izh into an arbitrary folder from the website 2 Execute MINICUBE Utilities Wxxx Izh in the arbitrary folder 3 The following folders and files will be created in the arbitrary folder MINICUBE Utilities Vxxx MINICUBE Utilities Vxxx MINICUBE Utilities Document Vxxx readme j
37. er s Manual U18591EJ2VOUM 21 CHAPTER 4 OCD CHECK FOR MINICUBE2 AND V850 MICROCONTROLLER 6 Click the Exit button Em OCD Checker Device file folder CXProgram Files NEG Electronics ToalzDEV Exit Mode of the emulator Target Device Connection Device uPD 70F3732 Port CSIBO Internal ROM Security ID Code Sepak C i Main QSCOMHz 5 0 Log file CX Temp IEQCDUTL log L OK Emulator Test End 4 2 Format of Log File The following shows an example of the log file when the check results show OK statuses Execution time tt mm ss VDD status Target Power 3 2V Reset status Target Reset HIGH Hardware version MINICUBE2 4100 x xx xx Program Download OK Run Test OK Check result Flash Erase OK ALL OK Emulator Test End e Execution time The time when checking was started by clicking the Test button e Vpp status Voo value that is applied to the target device e Reset status RESET pin status HIGH Reset signal input from the target system is HIGH LOW Reset signal input from the target system is LOW e Hardware version Version of each hardware e Check result Program Download ID verification result of downloading to flash memory in the target device Run Test Result of executing and stopping the program Flash Erase Erasure result of flash memory in the target device 22 User s Manual U18591EJ2V0UM CHAPTER 4 OCD CHECK FOR MINICUBE2 AND V850 MICROCONTROLLER Remark T
38. erminates the OCD Checker 11 System menu Version can be checked by clicking About OCD Checker on the System menu Remark Settings for the OCD Checker are maintained when the OCD Checker is started the next time except for the setting in the Internal ROM Security setting area User s Manual U18591EJ2V0UM 13 CHAPTER 3 OCD CHECK FOR MINICUBE2 AND 78K0 MICROCONTROLLER This section describes the method to check the connection between MINICUBE2 and the target system which uses a 78K0 microcontroller as the target device using the OCD Checker 3 1 Execution of OCD Check Be sure to terminate the debugger QBP and MINICUBE2 diagnostic tool before executing the OCD Checker Perform the connection check according to the following steps 1 to 6 1 MINICUBE2 setup e Power select switch Set the switch corresponding to the target system e Mode select switch Set to M2 e 8K0 OCD board Connect the board in accordance with MINICUBE2 User s Manual U18371E e Target cable Connect the cable having a pin count corresponding to the target system 16 pin or 10 pin 2 Connection and power application Connect MINICUBE2 to the target system in accordance with MINICUBE2 User s Manual U18371E and the turn on power to the target system 3 Setting the OCD Checker Refer to 2 3 Explanation of Each Area e Emulator mode select area Select MINICUBE2 78K0 e Clock select area Select internal or socket
39. fice equipment communications equipment test and measurement equipment audio and visual equipment home electronic appliances machine tools personal electronic equipment and industrial robots High Quality Transportation equipment automobiles trains ships etc traffic control systems anti disaster systems anti crime systems safety equipment and medical equipment not specifically designed for life support Specific Aircraft aerospace equipment submersible repeaters nuclear reactor control systems medical equipment or systems for life support e g artificial life support devices or systems surgical implantations or healthcare intervention e g excision etc and any other applications or purposes that pose a direct threat to human life You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics especially with respect to the maximum rating operating supply voltage range movement power voltage range heat radiation characteristics installation and other product characteristics Renesas Electronics shall have no liability for malfunctions or damages arising out of the use of Renesas Electronics products beyond such specified ranges Although Renesas Electronics endeavors to improve the quality and reliability of its products semiconductor products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions un
40. granted hereby under any patents copyrights or other intellectual property rights of Renesas Electronics or others You should not alter modify copy or otherwise misappropriate any Renesas Electronics product whether in whole or in part Descriptions of circuits software and other related information in this document are provided only to illustrate the operation of semiconductor products and application examples You are fully responsible for the incorporation of these circuits software and information in the design of your equipment Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from the use of these circuits software or information When exporting the products or technology described in this document you should comply with the applicable export control laws and regulations and follow the procedures required by such laws and regulations You should not use Renesas Electronics products or the technology described in this document for any purpose relating to military applications or use by the military including but not limited to the development of weapons of mass destruction Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose manufacture use or sale is prohibited under any applicable domestic or foreign laws or regulations Renesas Electronics has used reasonable care in preparing the information included in this document
41. he Emulator Utilities check box when installing CubeSuite V1 00 or later The MINICUBE OCD Checker is then installed automatically e Select the MINICUBE Utilities Vx xx check box when installing ID78KO QB V2 93 or later The OCD Checker is then installed automatically e Select the MINICUBE Utilities Vx xx check box when installing ID850QB V3 20 or later The OCD Checker is then installed automatically e Select the MINICUBE Utilities Vx xx check box when installing QBP V1 00 or later The OCD Checker is then installed automatically e Select the MINICUBE Utilities Vx xx check box when installing ID78KOS QB V2 82 or later The OCD Checker is then installed automatically e Select the MINICUBE Utilities Vx xx check box when installing ID78KOR QB V3 20 or later The OCD Checker is then installed automatically Caution If multiple debuggers are installed MINICUBE Utilities Vx xx MINICUBE OCD Checker in the Latest Version folder is overwritten When an ID78K0 QB or ID78K0S QB earlier than V3 00 is installed the OCD Checker in the NEC Tools32 folder is overwritten Remark The MINICUBE2 diagnostic tool is installed when the OCD Checker is installed R 2 1 2 Startup Start the OCD Checker using either of the following procedure e When using CubeSuite Click the Start menu of Windows point to Programs NEC Electronics CubeSuite Emulator Utilities Target Device gt and then click OCD Check
42. he radio button the clock supplied to the emulator e internal When a clock mounted in the emulator is used e socket When a clock mounted in the CLK1 socket of the MINICUBE2 78K0 OCD board and a clock mounted in the CLK1 socket of the 78K0 MINICUBE or 78K0S MINICUBE are used e Main OSC MHz Input the target system clock frequency when MINICUBE2 V850 is selected Internal ROM Security setting area To set the ID code select the ID Code check box otherwise the ID code is handled as OxFF If MINICUBE2 V850 is selected this area is available only when a debug monitor program has been written to the target device This area is unavailable if MINICUBE2 78K0S or 78KOS MINICUBE is selected for the emulator mode Log file button Specifies the file to which the check log will be output log file The location for saving the log file can be changed by clicking the Log file button The log file is created as IEOCDUTL log in a temporary folder by default Normally the temporary folder is specified in the tmp or temp environmental variable Test button Starts checking The checked items and their result are output to the log file Log view window Displays the check result The contents displayed in this area are also output to the log file that is specified using the 6 Log file button Clear button Clears the log view window The contents output to the log file are not cleared 10 Exit button T
43. he version of MINICUBE2 can also be checked with the MINICUBE2 diagnostic tool debugger and QBP The latest version of MINICUBE2 firmware can be checked on the following NEC Electronics websites Japanese version http www necel com micro ods jpn index html English version http www necel com micro ods eng index html See Version up service gt MINICUBE2_ Software 4 3 Error Output The following describes the operation and display example when an NG is displayed as a result of 4 1 Execution of OCD Check The message just indicates NG but there are various causes 1 The result is displayed in the dialog box Click the OK button 2 The contents displayed in the log view window are saved in the log file Log view window 7 OGD Checker Device file folder CXProgram Files MEG Electronics ToolzDE V Exit Mode of the emulator Target Device Connection Device uPD OFS ide Port CSIBD i Internal ROM Security Main CSC MHz 2 Log file GX TempiIEOGDLTL lag 09 53 35 Target Power 32V Target Reset HIGH MINICUBE 4100 4 144 01 Program Download NG Emulator Test End User s Manual U18591EJ2VOUM 23 CHAPTER 4 OCD CHECK FOR MINICUBE2 AND V850 MICROCONTROLLER Log file Execution time tt mm ss VDD status OK Target Power 3 2V Reset status OK Target Reset HIGH Hardware version MINICUBE2 4100 x xx xx Error indication Program Download NG Emulator Test End In this NG example the e
44. hecked with the debugger version consult an NEC Electronics sales representative or distributor See QB 78KOMINI OCD Control Code Vx xx MINICUBE 78KO 4000 x x xx Program Download OK Run Test OK Flash Erase OK ALL OK Emulator Test End The time when checking was started by clicking the Test button Frequency of the selected clock Vpp value that is applied to the self check board RESET pin status HIGH Reset signal input from the self check board is HIGH LOW Reset signal input from the self check board is LOW Version of each hardware Program Download ID verification result of downloading to flash memory in the target device self check board Run Test Result of executing and stopping the program Flash Erase Erasure result of flash memory in the target device self check board User s Manual U17029E for the control code of the OCD Checker User s Manual U18591EJ2VOUM For the latest CHAPTER 7 OCD CHECK FOR 78K0 MINICUBE 7 3 Error Output The following describes the operation and display example when an NG is displayed as a result of 7 1 Execution of OCD Check The message just indicates NG but there are various causes 1 The result is displayed in the dialog box Click the OK button EocDUTL 2 The contents displayed in the log view window are saved in the log file Log view window L7 OGD Checker Mode of the emulator Target Device Connection Device Port
45. ile of the program written to the self check board and connection between the self check board and MINICUBE 2 Target Power OFF The power supply to the self check board cannot be detected Confirm that LED1 on the self check board glows Check the connection between the self check board and MINICUBE 3 Target Clock 0 00MHz NG The clock mounted in the CLK1 socket may not be operating Confirm the clock oscillation or remove the clock mounted in the CLK1 socket and use the internal clock 4 Select Socket Clock The clock mounted in the CLK1 socket is not selected Select socket for the clock setting or remove the clock mounted in the CLK1 socket and select internal 5 Driver open error 1 There is no response from the 78K0 MINICUBE Check the connections between the host machine and the USB cable and the USB cable and the 78K0 MINICUBE Turn all the power supplies off according to the procedures described in the user s manual The 78K0 MINICUBE is turned off by disconnecting the USB cable Turn all the power supplies on and then click the Test button If an error message is displayed even after taking these measures restart Windows on the host machine before turning all the power supplies on 2 The debugger has been started The debugger and the OCD Checker cannot be started simultaneously so terminate the debugger 3 The USB driver may not be operating normal
46. ker mi ID Cade loe Log file IDATMPNIEDEDUTL log Click About OCD Checker on the system menu the version information window then appears L7 OCD Checker es NEC Electronics ToolsADEW Move Size arget Device Connection vice UPD7SF1166_Al v Port TOOLO TOC AlELFA Internal ROM Security About OCD Checker if ID Code oT OCD Checker OCD Checker E2 30c 8 Jun 2006 LE Copyright C MEC Electronics Corporation 006 k 50 User s Manual U18591EJ2VOUM CHAPTER 10 UNINSTALLATION This section explains how to uninstall the OCD Checker Note the following points when uninstalling the OCD Checker e The MINICUBE2 diagnostic tool is uninstalled at the same time e The log files are not deleted by uninstalling the OCD Checker Perform uninstallation according to the following steps 1 to 5 1 Turn on power to the host machine and start Windows 2 Start Add Remove Programs or Add or Remove Programs in the Control Panel 3 Select the relevant item from the list displayed on the Install Uninstall tab and then click the Add Remove or Change Remove button e To uninstall the OCD Checker NEC EL MINICUBE Utilities Vx xx e o uninstall this document NEC EL MINICUBE Utilities Vx xx Documents 4 A dialog box for confirming deletion of files will be displayed Click the Yes button deleting the files will then be started 5 When the completion message is displayed click the OK
47. le Binary file that contains device dependent information It is prepared for each target device or group of devices in the same lineup Please use the following documents in combination with this manual The related documents listed below may include preliminary versions However preliminary versions are not marked as such O Documents Related to Development Tools User s Manuals ID78KOR QB Ver 3 20 Integrated Debugger Operation U17839E ID78KOS QB Ver 2 90 Integrated Debugger Operation U18247E ID850QB Ver 3 20 Integrated Debugger Operation U17435E QB Programmer Programming GUI Operation U18527E MINICUBE2 Diagnostic Tool U18588E Caution The related documents listed above are subject to change without notice Be sure to use the latest version of each document for designing etc Users Manual U18591EJ2VOUM 5 CONTENTS CHAPTER T OVERVIEW uri iia 8 TA MINICUBE OCD Checker ciiisean ea eae oue ve aeo Pee iio ea opes ve aeo noes 8 1 2 Target Emulators and Items to Be Checked eeee cesses eese nennen nnns 8 1 3 Notes Before Using OCD Checker 1 eeleeeeeeieeeeeiieeee eene e nne n nnne nn nnn nnn nnn nnns 9 CHAPTER 2 INSTALLATION AND STARTUP 4 eeesseeeniieee seen nnn nnn h nnns annua a nsns a usas anna a nnns 10 2 1 When NEC Electronics Tool Is Used iir aida 10 Zu t EB Iouem A E 10 AS UU ISCRITTI EE CENE 1
48. log box is displayed as shown below The contents displayed in the log view window are saved in the log file If an NG is displayed refer to 7 3 Error Output and 7 4 Action for Error Z OGD Checker Mode of the emulator 78KO MINIGUBE Glock C socket r Target Device Connection Device Port l 4 TS ROM SOON Bonn 3 AERE EC ORE MESE EK ORENSE CE fe uc IG TempxIEOCD Target Power 49 OK Target Reset HIGH OCD Control Code 44 00 MINICUBE 8K0 4000 C 14 11 Program Download OK Run Test OK Boot swap ON Flash Eraze OK ALL OK Emulator Test End 5 Click the Exit button 5 Er OCD Checker l Exit T larget Device Connection Device Port 3 Mode of the emulator ORO MINIGUEE 7 Glock socket internal EP ROM SOIT m ID Code ooo e ooo e c ooo O Te mpYIEQCDUTL loe Log file Emulator Test End Users Manual U18591EJ2VOUM 39 7 2 40 Format of Log File CHAPTER 7 OCD CHECK FOR 78K0 MINICUBE The following shows an example of the log file Execution time tt mm ss Clock status Target Clock 5 00MHz OK VDD status Target Power 4 8V OK Reset status Target Reset HIGH Hardware version Check result e Execution time e Clock status e Vpop status e Reset status e Hardware version e Check result Remark The version of the 78KO MINICUBE can also be c
49. ly Confirm the cable connection and the USB driver setup Re install the USB driver as necessary 4 The debugger may not be installed normally Re install the debugger Incorrect ID code The input ID code is incorrect Confirm the ID code written to the target device and re input the ID code 42 User s Manual U18591EJ2VOUM CHAPTER 7 OCD CHECK FOR 78K0 MINICUBE 2 2 Error message and action Log file write error The specified log file cannot be accessed Confirm that the folder path and file are write enabled Test Rom Command xxH Error Monitor Command xxH Error Communication between the target device on the self check board and MINICUBE has failed gt The cause may be a problem in the electrical specifications of the cable or the self check board or the USB driver may not be operating normally Confirm the connection and restart Windows on the host machine i Write Memory Read Memory Data verify error The internal RAM cannot be accessed The target device on the self check board may be damaged Exchange the target device _ Flash Env Error Flash Get Info Error Flash Block Blank Check Error Flash Block Erase Error Flash Word Write Error Flash Block Verify Error Flash Word Read Error Data Verify Error An error occurred while writing to the flash memory gt The cause may be the security flag setting so clear the security flag setting via the QBP The target device on the
50. n the 78K0S MINICUBE In such a case consult an NEC Electronics sales representative or distributor 48 1 2 Error message and action Communication Error There is no response from the QB 78KOSKX1 DA Check the connection between the OCD I F board or OCD I F cable and the QB 78KOSKX1 DA and QB 78KOSMINI Target Power OFF The power supply to the QB 78KOSKX1 DA cannot be detected Confirm that the power switch on the QB 78KOSKX1 DA is turned on Check the connection between the OCD I F board or OCD I F cable and the QB 78KOSKX1 DA and QB 78KOSMINI Target Clock 0 00MHz NG The clock mounted in the CLK1 socket may not be operating Confirm the clock oscillation or remove the clock mounted in the CLK1 socket and use the internal clock Select Socket Clock The clock mounted in the CLK1 socket is not selected gt Select socket for the clock selection or remove the clock mounted in the CLK1 socket and select internal Driver Open Error 1 There is no response from the 78KOS MINICUBE Check the connections between the host machine and the USB cable and the USB cable and the QB 78KOSMINI gt Turn all the power supplies off according to the procedures described in the user s manual The QB 78KOSMINI is turned off by disconnecting the USB cable Turn all the power supplies on and then click the Test button If an error message is displayed even after taking these measu
51. ocket internal f ID Gode paco Log file CG3Xtmp MGBLITL Iog Target Glock 20 00MHz OK Target Power 51V OK Emulator Test End Users Manual U18591EJ2VOUM 15 CHAPTER 3 OCD CHECK FOR MINICUBE2 AND 78K0 MICROCONTROLLER 3 2 Format of Log File The following shows an example of the log file when the check results show OK statuses Execution time gt tttmm ss Clock status Target Clock 20 00MHz OK VDD status Target Power 5 1V OK Reset status Target Reset HIGH OCD Control Code Vx xx Hardware version MINICUBE2 4100 x xx xx Program Download OK Run Test OK Flash Erase OK ALL OK Emulator Test End Check result e Execution time The time when checking was started by clicking the Test button e Clock status Frequency of the selected clock e Vpop status Voo value that is applied to the target device e Reset status RESET pin status HIGH Reset signal input from the target system is HIGH LOW Reset signal input from the target system is LOW e Hardware version Version of each hardware e Check result Program Download ID verification result of downloading to flash memory in the target device Run Test Result of executing and stopping the program Flash Erase Erasure result of flash memory in the target device Remark The version of MINICUBE2 can also be checked with th
52. rance Tel 01 3067 5800 Sucursal en Espa a Juan Esplandiu 15 28007 Madrid Spain Tel 091 504 2787 Tyskland Filial T by Centrum Entrance S 7th floor 18322 Taby Sweden Tel 08 638 72 00 Filiale Italiana Via Fabio Filzi 25 A 20124 Milano Italy Tel 02 667541 Branch The Netherlands Steijgerweg 6 5616 HS Eindhoven The Netherlands Tel 040 265 40 10 Asia amp Oceania NEC Electronics China Co Ltd 7th Floor Quantum Plaza No 27 ZhiChunLu Haidian District Beijing 100083 P R China Tel 010 8235 1155 http www cn necel com Shanghai Branch Room 2509 2510 Bank of China Tower 200 Yincheng Road Central Pudong New Area Shanghai PR China P C 200120 Tel 021 5888 5400 http www cn necel com Shenzhen Branch Unit 01 39 F Excellence Times Square Building No 4068 Yi Tian Road Futian District Shenzhen P R China P C 518048 Tel 0755 8282 9800 http www cn necel com NEC Electronics Hong Kong Ltd Unit 1601 1613 16 F Tower 2 Grand Century Place 193 Prince Edward Road West Mongkok Kowloon Hong Kong Tel 2886 9318 http www hk necel com NEC Electronics Taiwan Ltd 7F No 363 Fu Shing North Road Taipei Taiwan R O C Tel 02 8175 9600 http www tw necel com NEC Electronics Singapore Pte Ltd 238A Thomson Road 1112 08 Novena Square Singapore 307684 Tel 6253 8311 http www sg necel com NEC Electronics Korea Ltd 11F Samik Lavied or Bldg 720 2
53. re turning all the power supplies on 3 Check if the target device name matches the name specified in the Device drop down list in the Target Device Connection area Program Download NG An error occurred while writing to the flash memory 1 Check the connections between the target device and MINICUBE2 2 Check the power supply to the target system 3 The cause may be the security flag setting so clear the security flag setting via the flash memory programmer 4 The target device may be damaged so exchange the target device 5 Check the MINICUBE2 settings 6 Check the circuit for connecting MINICUBE2 Users Manual U18591EJ2VOUM 31 CHAPTER 6 OCD CHECK FOR MINICUBE2 AND 78K0R MICROCONTROLLER This section describes the method to check the connection between MINICUBE2 and the target system which uses a 78KOR microcontroller as the target device using the OCD Checker 6 1 32 Execution of OCD Check Be sure to terminate the debugger QBP and MINICUBE2 diagnostic tool before executing the OCD Checker The 78K0 OCD board and 10 pin target cable accessories of MINICUBE2 are not used Perform the connection check according to the following steps 1 to 6 1 2 3 MINICUBE2 setup e Power select switch Set the switch corresponding to the target system e Mode select switch Set to M1 e Target cable Connect the 16 pin target cable Connection and power application Connect MINICUB
54. reproduced in any form or by any means without the prior written consent of NEC Electronics NEC Electronics assumes no responsibility for any errors that may appear in this document e NEC Electronics does not assume any liability for infringement of patents copyrights or other intellectual property rights of third parties by or arising from the use of NEC Electronics products listed in this document or any other liability arising from the use of such products No license express implied or otherwise is granted under any patents copyrights or other intellectual property rights of NEC Electronics or others e Descriptions of circuits software and other related information in this document are provided for illustrative purposes in semiconductor product operation and application examples The incorporation of these circuits software and information in the design of a customer s equipment shall be done under the full responsibility of the customer NEC Electronics assumes no responsibility for any losses incurred by customers or third parties arising from the use of these circuits software and information e While NEC Electronics endeavors to enhance the quality reliability and safety of NEC Electronics products customers agree and acknowledge that the possibility of defects thereof cannot be eliminated entirely To minimize risks of damage to property or injury including death to persons arising from defects in NEC Electronics products customers m
55. res restart Windows on the host machine before turning all the power supplies on 2 The debugger has been started The debugger and the OCD Checker cannot be started simultaneously so terminate the debugger 3 The USB driver may not be operating normally Confirm the cable connection and the USB driver setup Re install the USB driver as necessary 4 The debugger may not be installed normally Re install the debugger User s Manual U18591EJ2VOUM CHAPTER 8 OCD CHECK FOR 78K0S MINICUBE 2 2 Error message and action Log file write error The cause may be The specified log file cannot be accessed Confirm that the folder path and file are write enabled Test Rom Command xxH Error Monitor Command xxH Error Communication between the QB 78KOSKX1 DA and QB 78KOSMINI has failed gt The cause may be a problem in the electrical specifications of the cable or the target board or the USB driver may not be operating normally Confirm the connection and restart Windows on the host machine User s Manual U18591EJ2V0UM 49 CHAPTER 9 OCD CHECKER VERSION INDICATION This section describes the method to check the version Click the icon on the title bar or right click the title bar the system menu is then displayed OCD Checker bs4NEC Electronics Tools DEY Move Size target Device Connection VICE uPD7BFT156 Al Port TOOLOTOC Internal ROM Security Close Alt F4 About cco Chec
56. rror Program Download is detected An error during flash memory programming is detected The cause is an error in pin connection on the board for connecting MINICUBE2 on the target system pin 5 SO is shorted with GND 4 4 Action for Error The errors that may occur during self testing such as setting error and relevant actions for coping with the errors are listed below If an error other than below is displayed the cause may be a defect in MINICUBE2 If the same error is displayed even after the relevant action is implemented the cause may be a defect in MINICUBE2 In such a case consult an NEC Electronics sales representative or distributor 1 2 Error message and action 1 There is no response from MINICUBE2 Check the connections between the host machine and the USB cable and the USB cable and the MINICUBE2 Turn all the power supplies off according to the procedures described in the user s manual MINICUBE2 is Turn all the power supplies on and then click the Test button If an error message is displayed even after taking these measures restart Windows on the host machine before turning all the power supplies on turned off by disconnecting the USB cable 2 The debugger has been started The debugger and the OCD Checker cannot be started simultaneously so terminate the debugger 3 The USB driver may not be operating normally Confirm the cable connection and the USB driver setup Re inst
57. s LOW e Hardware version Version of each hardware e Check result Program Download ID verification result of downloading to flash memory in the target device Run Test Result of executing and stopping the program Flash Erase Erasure result of flash memory in the target device 28 User s Manual U18591EJ2VOUM CHAPTER 5 OCD CHECK FOR MINICUBE2 AND 78K0S MICROCONTROLLER Remark The version of MINICUBE2 can also be checked with the MINICUBE2 diagnostic tool debugger and QBP The latest version of MINICUBE2 firmware can be checked on the following NEC Electronics websites Japanese version http www necel com micro ods jpn index html English version http www necel com micro ods eng index html See Version up service gt MINICUBE2_ Software 5 3 Error Output The following describes the operation and display example when an NG is displayed as a result of 5 1 Execution of OCD Check The message just indicates NG but there are various causes 1 The result is displayed in the dialog box Click the OK button 1 IEOCDUTL EJ 2 The contents displayed in the log view window are saved in the log file Log view window L7 OGD Checker Device file falder DANECTooles2 DEV Exit Mode of the emulator Target Device Connection Device juPD7B8F3234 Port r Internal ROM Security Target Reset HIGH MINICUBE 4100 4 4 01 Program Download MG Emulator Test End User s Manual U18591EJ2V
58. ust incorporate sufficient safety measures in their design such as redundancy fire containment and anti failure features e NEC Electronics products are classified into the following three quality grades Standard Special and Specific The Specific quality grade applies only to NEC Electronics products developed based on a customer designated quality assurance program for a specific application The recommended applications of an NEC Electronics product depend on its quality grade as indicated below Customers must check the quality grade of each NEC Electronics product before using it in a particular application Standard Computers office equipment communications equipment test and measurement equipment audio and visual equipment home electronic appliances machine tools personal electronic equipment and industrial robots Special Transportation equipment automobiles trains ships etc traffic control systems anti disaster systems anti crime systems safety equipment and medical equipment not specifically designed for life Support Specific Aircraft aerospace equipment submersible repeaters nuclear reactor control systems life support systems and medical equipment for life support etc The quality grade of NEC Electronics products is Standard unless otherwise expressly specified in NEC Electronics data sheets or data books etc If customers wish to use NEC Electronics products in applications not inten
59. utput The communication failure between the target device and MINICUBE2 is detected The cause is an error in the target cable connection between the target system and MINICUBE2 User s Manual U18591EJ2VOUM 17 CHAPTER 3 OCD CHECK FOR MINICUBE2 AND 78K0 MICROCONTROLLER 3 4 Action for Error The errors that may occur during self testing such as setting error and relevant actions for coping with the errors are listed below If an error other than below is displayed the cause may be a defect in MINICUBE2 If the same error is displayed even after the relevant action is implemented the cause may be a defect in MINICUBE2 In such a case consult an NEC Electronics sales representative or distributor 18 1 2 Error message and action Communication error There is no response from the target device gt Address 0x84 on chip debug emulator use enable flag is set to 0x00 disable use or the target system and MINICUBE2 are not connected correctly Confirm the file of the program written to the target device and connection between the target system and MINICUBE2 Target Power 0 0V NG The power supply to the target system cannot be detected Confirm that the power for the target system is on Check the connection between the target system and MINICUBE2 78K0 OCD board is not connected The 78K0 OCD board is not connected Confirm that the 78K0 OCD board is connected Target Clock 0 00MHz
60. vice file folder CXProgram Files MEC Electronics ToalzDEV Exit Mode of the emulator Target Device Connection Device juPDFSFIT66_A0 Port TOOLO TOOLT Internal ROM Security I ID Code Sepak Loe file C Temp lIEQODUTL log 08 35 03 Target Power 32 OK Target Reset HIGH MINICUBE 4100 4 144 07 Program Download NG Emulator Test End Users Manual U18591EJ2VOUM 35 CHAPTER 6 OCD CHECK FOR MINICUBE2 AND 78K0R MICROCONTROLLER Log file Execution time gt ttmm ss VDD status OK gt Target Power 3 2V OK Reset status OK gt Target Reset HIGH Hardware version gt MINICUBE2 4100 x xx xx Error indication Program Download NG Emulator Test End In this NG example the error Program Download is detected An error during flash memory programming is detected The cause is an error in pin connection on the board for connecting MINICUBE2 on the target system pin 3 RXD is shorted with GND 6 4 Action for Error The errors that may occur during self testing such as setting error and relevant actions for coping with the errors are listed below If an error other than below is displayed the cause may be a defect in MINICUBE2 If the same error is displayed even after the relevant action is implemented the cause may be a defect in MINICUBE2 In such a case consult an NEC Electronics sales representative or distributor 1 2 Error message and action 1 There is no response from MINICUBE2
61. vice may be damaged so exchange the target device 6 Check the MINICUBE2 settings 7 Check the circuit for connecting MINICUBE2 Users Manual U18591EJ2VOUM 37 CHAPTER 7 OCD CHECK FOR 78K0 MINICUBE This section describes the method to check the connection between the 78KO MINICUBE and self check board accessory using the OCD Checker 7 1 Execution of OCD Check Be sure to terminate the debugger before executing the OCD Checker Perform the connection check according to the following steps 1 to 4 1 Connection Connect the 78K0 MINICUBE to the self check board in accordance with the 78KO MINICUBE user s manual 2 Setting the OCD Checker Refer to 2 3 Explanation of Each Area e Emulator mode select area Select 78KO MINICUBE e Clock select area Select internal or socket e Internal ROM Security setting area Input the ID code e Log file button Specify the log file name and the location for saving the log file 3 Click the Test button If an error occurs during checking refer to 7 3 Error Output and 7 4 Action for Error 7 OCD Checker E Device file folder Exit e Mode of the emulator Target Device Cooper 3 TORO MINIGUBE hi Device Glac i Internal Rahl setur it socket Test f internal fv ID Code PEERKE C TempRECOGDUTL log 38 User s Manual U18591EJ2V0UM CHAPTER 7 OCD CHECK FOR 78K0 MINICUBE 4 When all of the tests are complete the result dia

Download Pdf Manuals

image

Related Search

Related Contents

Système Étroit Superbe De Projection 3M™ SCP712 Guide de l  Mostrar - Service, Support  Manuale Utente Raptor - 1,98 Mb, Data  ergotherapie - Schulz  13 薬食安発0623第1号(H26.06.23) (PDF : 1MB)  The Air Shadow™ - Del Mar Fans and Lighting  LES ARTS ET LE DROIT D`AUTEUR  Dremel MS20-01 Use and Care Manual  取扱説明書  Licht wird Architektur Dolma steht in elegantem Dialog mit  