1. CFW11 NEMA1 Frame size A E IP20 Frame Size F and G Normal Duty pe ae VT 110 1min 1min App Mul our o TA ND upgp P CATALOG NUMBER Endosure pp DIMENSIONS erro Wt St tiplier Volts HP Amps Amps Size HxWxD Price Ibs Symbol INPUT POWER SUPPLY SINGLE OR THREE PHASE 200 240V 1 5 6 1 5 5 CFW110006B20N1Z A NEMA 1 YES 12 04 x 5 71 x 8 94 19 9 1 644 V1 2 1 2 T CFW110007B20N1Z A NEMA 1 12 04 x 5 71 x 8 94 20 8 1 716 V1 INPUT POWER SUPPLY SINGLE PHASE 200 240V 3 10 10 CFW110010S20N1Z A NEMA 1 YES 12 04 x 5 71 x 8 94 20 8 1 812 V1 INPUT POWER SUPPLY THREE PHASE 200 240V 2 T 1 5 5 5 CFW110007T20N1Z A NEMA 1 YES 12 04 x 5 71 x 8 94 19 9 1 620 V1 d 10 2 8 CFW110010T20N1Z A NEMA 1 12 04 x 5 71 x 8 94 19 9 1 692 V1 5 13 3 11 CFW110013T20N1Z A NEMA 1 12 04 x 5 71 x 8 94 20 8 1 728 V1 5 16 5 13 CFW110016T20N1Z A NEMA 1 12 04 x 5 71 x 8 94 21 2 1 850 V1 7 5 24 7 5 20 CFW110024T20N1Z B NEMA 1 13 82 x 7 45 x 8 94 20 5 2 424 V1 a 10 28 10 24 CFW110028T20N1Z B NEMA 1 13 82 x 7 45 x 8 94 28 5 2 641 V1 N 10 33 5 10 28 CFW110033T20N1Z B NEMA 1 13 82 x 7 45 x 8 94 28 5 3 190 V1 15 45 15 36 CFW110045T20N1Z E NEMA 1 17 64 x 8 66 x 11 51 44 1 3 641 V1 20 54 20 45 CFW110054T20N1Z C NEMA 1 17 64 x 8 66 x 11 51 45 4 400 V1 25 70 20 56 CFW110070T20N1Z C NEMA 1 17 64 x 8 66 x 11 51 49
2. 2 6 600 V1 30 86 25 70 CFW110086T20N1Z D NEMA 1 19 82 x 11 81 x 12 115 9 7 222 V1 40 105 30 86 CFW110105T20N1Z D NEMA 1 19 82 x 11 81 x 12 120 2 9 000 V1 50 142 40 115 CFW110142T20N1Z E NEMA 1 NO 26 6 x 13 2 x 14 1 150 11 649 V1 60 180 50 142 CFW110180T20N1Z E NEMA 1 26 6 X 13 2 x 14 1 150 15 125 V1 fo 211 60 180 CFW110211T20N1Z E NEMA 1 26 6 x 13 2 x 14 1 150 21 560 V1 50 142 40 115 CFW110142T20N1DBZ E NEMA 1 YES 26 6 X 13 2 x 14 1 150 12 720 V1 60 190 50 142 CFW110180T20N1DBZ E NEMA 1 26 6 x 13 2 x 14 1 150 17 555 V1 75 211 60 180 CFW110211T20N1DBZ E NEMA 1 26 6 x 13 2 x 14 1 150 24 380 V1 INPUT POWER SUPPLY THREE PHASE 380 480V 2 3 6 2 3 6 CFW110003T40N1Z A NEMA 1 YES 12 04 x 5 71 x 8 94 19 9 1 616 V1 3 5 3 5 CFW110005T40N1Z A NEMA 1 12 04 x 5 71 x 8 94 20 3 1 650 V1 5 T 3 5 5 CFW110007T40N1Z A NEMA 1 12 04 x 5 71 x 8 94 20 3 1 712 V1 7 5 10 5 10 CFW110010T40N1Z A NEMA 1 12 04 x 5 71 x 8 94 20 8 1 969 V1 10 13 5 CFW110013T40N1Z A 12 04 x 5 71 x 8 94 21 2 2 068 V1 10 17 CFW110017T40N1Z B 13 82 x 7 45 x 8 94 28 5 2 530 V1 15 24 CFW110024T40N1Z B 13 82 x 7 45 x 8 94 29 8 2 992 V1 20 31 CFW110031T40N1Z B 13 82 x 7 45 x 8 94 31 3 3 873 V1 25 38 CFW110038T40N1Z C 17 64 x 8 66 x 11 51 45 9 4 300 V1 30 45 CFW110045T40N1Z C 17 64 x 8 66 x 11 51 52 9 5 400 V1 40 58 5 CFW110058T40N1Z C 17 64 x 8 66 x 11 51 54 9 6 633 V1 50 60 70 5 CFW110070T40N1Z D 19 82 x 11 81 x 12 119 5 7 500 V1 15 88 CFW110088T40N1Z D 19 82 x 11 81 x 12 122 8 8
3. HD Cycle m 15096 for 60 seconds every 10 minutes m 200 for 3 seconds every 10 minutes Sizing the drive The correct way to select a VSD is to match its output current with the motor rated current However the tables in this catalog also present the expected motor horsepower for each VSD model Use the motor power ratings only as a guide Motor rated currents may vary with speed and manufacturer IEC motor powers are based on WEG 4 pole motors NEMA motor powers are based on NEC table 430 150 Notes 1 Half controlled bridge rectiifer for sizes F and G 2 Standard for sizes A to D 3 Standard RFI filter for sizes E F and G Please refer to the user manual for more information A 50 1 800 ASK 4WEG Frame A Frame B Frame C Frame D Frame E Frame F Frame G Power l 4n network gt Motor Feedbacks Voltages Se a ee ee ee Meo Oo D Super Drive Software WLP Software Accessories MMI remote DM to DI6 Analog Inputs A1 and Al2 Analog Outputs AO1 and A02 Digital Outputs DO1 RL1 to l l I I l I I I I I I I I I I l l I I I l l l I I Digital Inputs I I l l I I I l I I I l l l I I I l i DO3 RL3 I I l l I Data is subject to change without notice Variable Frequenoy Drives CFW T1 Plug and Play The CFW11 inverter incorporates Plug and Play technology automatically recognizing and configuring
4. KrB DN SSwoo MM 0o MIM SSW07 See SSWO07 Accessories RS 485 Kit for PC is required when SUPERDRIVE communicates with a multi drive RS 485 network It is composed of a RS 232 RS 485 converter and a cable to connect to PC Superdrive WEG Superdrive is a windows based software program that allows serial RS 232 or RS 485 communication between a PC and all WEG Soft Starters and Variable Frequency Drives Superdrive is RN wm i Bi an excellent programming documentation and troubleshooting tool for WEG Soft Starters and VFD s RN p an Superdrive is available for free download at www weg net RS Hardware accessories may be required depending on the Soft Starter or VFD line S S Standard Features i SN m Online and Offline Soft Starter or VFD programming AN ME a Command and Monitoring RSS m Parameter set storage in a computer file format a f so A 60 1 800 ASK 4WEG Data is subject to change without notice
5. encoder interfaces RS 485 MODBUS RTU CAN CANopen DeviceNet CANopen master slave PROFIBUS DP 05 Profibus DP interface Anybus 4 Devicenet 05 Devicenet 4 interface Anybus 4 EtherNet IP 05 Ethernet IP interface Anybus 4 HMID 01 Blind cover for slot HMI RHMIF 01 Frame for remote HMI KN1A 01 Conduit kit for size A KN1B 01 Conduit kit for size B KN1C 01 Conduit kit for size C Note Anybus card goes in slot 4 and allows the user to combine PLC11 board with Profibus DP 05 Devicenet 05 or Ethernet IP 05 Data is subject to change without notice is WEG Automation Products and Solutions Variable Frequenoy Drives CFW11 Superdrive Programming Software an a 5 545 5 7 18 5 3 o SOAS e A Ns Ms is Magy My Mag si th ee R SS na Programming software for PC USB connection Windows environment for setpoint command and monitoring of CFW11 inverters Human Machine Interface Right soft key function defined by Left soft key function the text in the display defined by the text in the display Monitoring Modes TE a Bar Graphics b Numerical Values c Large Characters Data is subject to change without notice A 52 1 800 ASK AWEG Variable Frequenoy Drives
6. 11 V1 N 10 CFW110033T20N1Z CFDB5 19 3730 19 3 730 26 5x13x5 30s 2 511 V1 15 CFW110045T20N1Z CFDB5 13 5595 12 6 5 595 26 5x16x5 30s 2 938 V1 20 CFW110054T20N1Z CFDB5 10 7460 9 6 7 460 28x13x10 30s 4 663 V1 25 CFW11070T20N1Z CFDB5 8 9325 7 5 9 325 28x13x10 30s 4 663 V1 30 CFW110086T20N1Z CFDB5 7 11190 6 3 11 190 28x16x11 30s 5 254 V1 40 CFW110105T20N1Z CFDB5 5 14920 4 9 14 920 26 5x16x5 30s 6 762 V1 50 CFW110142T20N1Z CFDB5 4 18650 3 9 18 650 30x18x24 30s 10 325 V1 60 CFW110180T20N1Z CFDB5 4 22380 3 3 22 380 30x18x24 30s 10 325 V1 15 CFW110211T20N1Z CFDB5 3 27975 2 27 975 30x18x32 30s 15 393 V1 2 CFW110003T40N1Z CFDB5 375 746 375 146 12x13x5 30s 1 130 V1 3 CFW110005T40N1Z CFDB5 250 1119 12x16x5 30s 1 511 V1 5 CFW110007T40N1Z CFDB5 150 1865 19x13x5 30s 1 703 V1 1 5 CFW110010T40N1Z CFDB5 100 2798 19x16x5 30s 1 892 V1 10 CFW110013T40N1Z CFDB5 75 3730 26 5 5x16x5 30s 2 938 V1 10 CFW110017T40N1Z CFDB5 75 3730 26 5 5x16x5 30s 2 938 V1 15 CFW110024T40N1Z CFDB5 50 5595 28x13x10 30s 4 254 V1 20 CFW110031T40N1Z CFDB5 38 7460 28x13x10 30s 4 254 V1 25 CFW110038T40N1Z CFDB5 30 9325 28x16x10 30s 4 715 V1 30 CFW110045T40N1Z CFDB5 25 11190 11 190 28x16x10 30s 5 071 V1 40 CFW110058T40N1Z CFDB5 19 14920 14 920 30x18x24 30s 8 858 V1 2 50 60 CFW110070T40N1Z CFDB2 15 22380 22 380 30x18x24 30s 10 176 V1 SE 75 CFW110088T40N1Z CFDB5 10 27975 27 975 30x18x32 30s 14 625 V1 15 CFW110105T40N1Z CFDB5 10 27975 27 975 30x18x32 30s 14 625 V1 100 125 CFW110142T
7. 40N1Z CFDB5 8 46625 46 625 30x18x32 30s 16 923 V1 150 CFW110180T40N1Z CFDB5 5 55950 5 55 950 30x18x48 30s 18 814 V1 175 CFW110211T40N1Z CFDB5 5 74600 5 14 600 30x18x72 30s 31 678 V1 200 CFW110242T40N1Z CFDB5 4 74600 4 74 600 30x18x72 30s 31 678 V1 250 CFW110312T40N1Z CFDB5 3 93250 3 93 250 30x18x72 30s 31 678 V1 300 CFW110370T40N1Z CFDB5 3 111900 2 5 111 900 2 30x18x56 30s 54 028 V1 350 CFW110477T40N1Z CFDB5 3 130550 2 2 130 550 2 30x18x56 30s 54 028 V1 400 CFW110515T40N1Z CFDB5 2 149200 1 9 149 200 2 30x18x56 30s 73 288 V1 500 CFW110601T40N1Z CFDB5 2 186500 1 5 186 500 2 30x18x56 30s 73 288 V1 600 CFW110720T40N1Z Consult with WEG Notes These are non stocked items consult WEG for availability NEMA 1 Enclosure Braking time based on cycle of 60 seconds A 58 1 800 ASK AWEG Data is subject to change without notice is Variable Frequenoy Drives CFW11 Technical Data 200 240V 10 15 of rated voltage Supply 380 480V 10 15 of rated voltage Supply frequency 50 60Hz 2Hz Output frequency 0 to 300Hz Types of control Ambient temperature Vector with encoder Vector sensorless VV W voltage vector V F scalar 10 50 C up to 60 with output current reduction 2 C above 50 C Humidity 5 to 90 without condensation 0 to 1000m Altitude Up to 4000m without current reduction 1 n for each 100m above 1000m Dynamic braking up to 75HP b
8. 4T20N1Z CFDB2 10 2984 9 6 2 984 19x10x5 12s 1 644 V1 29 CFW11070T20N1Z CFDB2 8 3730 7 5 3 730 19x13x5 12s 1 997 V1 30 CFW110086T20N1Z CFDB2 7 4476 6 3 4 476 26 5x13x5 12s 2 588 V1 40 CFW110105T20N1Z CFDB2 5 5968 4 9 5 968 26 5x16x5 12s 3 269 V1 50 CFW110142T20N1Z CFDB2 4 7460 3 9 7 460 28x10x10 12s 3 820 V1 60 CFW110180T20N1Z CFDB2 4 8952 dui 8 952 28x10x10 12s 3 820 V1 75 CFW110211T20N1Z CFDB2 3 11190 2 7 11 190 28x13x10 125 5 622 V1 2 CFW110003T40N1Z CFDB2 375 298 3 5 298 12x7x5 12s 749 V1 3 CFW110005T40N1Z CFDB2 250 448 250 448 12x7x5 12s 749 V1 5 CFW110007T40N1Z CFDB2 150 746 150 746 12x10x5 12s 941 V1 7 5 CFW110010T40N1Z CFDB2 100 1119 100 12x13x5 1 130 V1 10 CFW110013T40N1Z CFDB2 75 1492 75 12x16x5 1 322 V1 10 CFW110017T40N1Z CFDB2 75 1492 15 12x16x5 1 322 V1 15 CFW110024T40N1Z CFDB2 50 2238 50 19x13x5 1 820 V1 20 CFW110031T40N1Z CFDB2 38 2984 38 19x16x5 2 201 V1 25 CFW110038T40N1Z CFDB2 30 3730 30 26 5x13x5 2 511 V1 30 CFW110045T40N1Z CFDB2 25 4476 25 26 5x13x5 2 511 V1 40 CFW110058T40N1Z CFDB2 19 5968 19 26 5x16x5 2 938 V1 50 60 CFW110070T40N1Z CFDB2 15 8952 15 8 952 28x13x10 4 328 V1 SP 15 CFW110088T40N1Z CFDB2 10 11190 10 11 190 28x16x10 5 659 V1 15 CFW110105T40N1Z CFDB2 10 11190 10 11 190 28x16x10 5 659 V1 100 125 CFW110142T40N1Z CFDB2 8 18650 8 18 650 30x18x24 9 560 V1 150 CFW110180T40N1Z CFDB2 5 22380 5 22 380 30x18x24 11 854 V1 175 CFW110211T40N1Z CFDB2 5 29840 5 29 840 30x18x24 11 854 V1 200 CFW110242T40N1Z CF
9. 900 V1 E 15 105 CFW110105T40N1Z E NO 26 6 x 13 2 x 14 1 150 10 650 V1 100 125 142 CFW110142T40N1Z E 26 6 x 13 2 x 14 1 150 12 500 V1 150 190 CFW110180T40N1Z E 26 6 x 13 2 x 14 1 150 17 500 V1 175 211 CFW110211T40N1Z E 26 6 x 13 2 x 14 1 150 21 000 V1 75 105 CFW110105T40N1DBZ E YES 26 6 x 13 2 x 14 1 150 13 600 V1 100 125 142 CFW110142T40N1DBZ E 26 6 x 13 2 x 14 1 150 15 900 V1 150 190 CFW110180T40N1DBZ E 26 6 x 13 2 x 14 1 150 23 115 V1 175 211 CFW110211T40N1DBZ E 26 6 x 13 2 x 14 1 150 27 020 V1 200 242 CFW110242T4SZ F NO 48 6 x 16 9 x 14 2 267 23 000 V1 250 312 CFW110312T4SZ F 48 6 x 16 9 x 14 2 271 29 366 V1 300 370 CFW110370T4SZ F 48 6 x 16 9 x 14 2 211 31 314 V1 350 477 300 370 CFW110477T4SZ F IP20 48 6 x 16 9 x 14 2 207 41 027 V1 400 515 350 477 CFW110515T4SZ G IP20 NO 50 x 21 1 x 16 8 420 43 970 V1 500 601 450 515 T CFW110601T4SZ G IP20 50 x 21 1x16 8 425 50 088 V1 600 120 500 601 T CFW110720T4SZ G IP20 50 x 21 1x16 8 441 59 330 V1 Notes HP rating based on FLA values from WEG W22 2 and 4 poles 460VAC NEMA Premium motors Use as a guide only Motor FLA may vary with speed and manufacturer ALWAYS compare motor FLA to Nominal AMPS of VFD and overload conditions T HD current rating with 140 O L WEG Automation Products and Solutions A 53 Data is subject to change without notice Weg Variable Frequency Drives CFW11 Options and Accessories List Multiplier DESCRIPTION C
10. ANopen DeviceNet Same as CFW700 CAN 01 410 V1 Profibus DP interface module Anybus card PROFDP 05 1 100 V1 E DeviceNet interface module Anybus card DEVICENET 05 1 100 V1 8 Ethernet IP interface module Anybus card ETHERNET IP 05 1 100 V1 RS 232 serial communication module Modbus RTU RS232 05 290 V1 RS 485 serial communication module Modbus RTU RS485 05 360 V1 4 PLC functions Ladder programming electronic gear box 9 digital inputs 3 dry contact eS digital outputs 3 open collector digital outputs 1 analog input 14 bits 2 analog outputs PLC11 01 1 876 Vi wes 14 bits 2 encoder interfaces RS 485 Mobus RTU interface CAN interface CANopen i o E CANopen master slave x Flash Memory Module for CFW11 MMF 01 71 V1 CFW11 keypad HMI 01 320 V1 zi Frame for keypad remote assembly RHMIF 01 69 V1 x Blank cover for keypad slot HMID 01 54 V1 2 1m 3 3ft remote keypad cable IHM CAB RS 1M 54 Vi 2m 6 6ft remote keypad cable IHM CAB RS 2M 60 V1 E 3m 10ft remote keypad cable IHM CAB RS 3M 66 V1 b5m 16ft remote keypad cable IHM CAB RS 5M 75 V1 S 7 5m 25ft remote keypad cable IHM CAB RS 7 5M 90 V1 3 10m 33ft remote keypad cable IHM CAB RS 10M 102 V1 o l z ee Ti replaces CFW REM NC and 1 NO contact block Potentiometer 5k CSW SP3PBS 460 75 amp READ ry ues aces CFW REM NC and 1 NO contact block Potentiometer 5k CSW30 SP3PBS 535 75 Conduit Kit for frame size A KN1A 01 69 V1 z Con
11. ATALOG NUMBER Price Symbol IOA Module for CFW11 1 analog input Al4 14 bits voltage or current 2 digital inputs 2 analog outputs A03 and A04 14 bits voltage or current 2 digital outputs open collector I0A 01 1 100 V1 All analog input and output are galvanic isolated 3 IOB Module for CFW11 2 isolated analog inputs AI3 and Al4 12 bits voltage or current 2 om digital inputs Provides Galvanic Isolation for AO1 and AQ2 11 bits voltage or current 2 IOB 01 600 V1 uj digital outputs open collector All analog inputs and outputs are galvanically isolated I0C 01 Module for SoftPLC 8 x Isolated Digital Inputs 4 x Relay output 240V 1A 10C 01 447 V1 I0C 02 Module for SoftPLC 8 x Isolated Digital Inputs 8 x open collector digital outputs l0C 02 411 V1 z E Incremental encoder module 5 to 12 VDC at 100 kHZ with encoder signal repeater ENC 01 500 V1 Incremental encoder module 5 to 12 VDC at 100 kHZ without encoder signal repeater ENC 02 430 V1 RS 485 serial communication module Modbus RTU RS485 01 240 V1 RS 232C serial communication module Modbus RTU RS232 01 180 V1 RS232C serial commuication module with DIP switches for microcontroller s flash memory RS232 02 180 Vi E programming CAN and RS 485 communication module CANopen Modbus DeviceNet CAN RS485 01 480 V1 CAN interface module C
12. DB2 4 29840 4 29 840 30x18x32 11 854 V1 250 CFW110312T40N1Z CFDB2 3 37300 3 37 300 30x18x32 12 533 V1 300 CFW110370T40N1Z CFDB2 3 44760 2 5 44 760 30x18x32 12s 15 393 V1 350 CFW110477T40N1Z CFDB2 3 52220 2 2 52 220 30x18x48 12s 21 406 V1 400 CFW110515T40N1Z CFDB2 2 59680 1 9 59 680 30x18x48 12s 22 167 V1 500 CFW110601T40N1Z CFDB2 2 74600 1 5 74 600 30x18x64 12s 32 077 V1 600 CFW110720T40N1Z Consult with WEG Notes These are non stocked items consult WEG for availability NEMA 1 Enclosure Maximum Braking time based on cycle of 60 seconds Data is subject to change without notice WEG Automation Products and Solutions A 57 Weg Variable Frequency Drives CFW11 DB Resistors 100 Braking Torque 50 Duty Cycle NEMA 1 Enclosure Motor Volts Motor HP UND Catalog Number E or emu List Price pese 1 5 CFW110006B20NIZ CFDB5 125 560 12x10x5 30s 941 V1 2 CFW11007B20N1Z CFDB5 95 746 12x10x5 30s 941 V1 2 CFW110007T20N1Z CFDB5 95 746 12x10x5 30s 941 V1 3 CFW110010S20N1Z CFDB5 63 1119 12x10x5 30s 1 130 V1 3 CFW110010T20N1Z CFDB5 63 1119 12x10x5 30s 1 130 V1 5 CFW110013T20N1Z CFDB5 38 1865 19x13x5 30s 1 820 V1 5 CFW110016T20N1Z CFDB5 38 1865 19x13x5 30s 1 820 V1 7 5 CFW110024T20N1Z CFDB5 26 2798 26 5x13x5 30s 2 511 V1 z gt 10 CFW11028T20N1Z CFDB5 19 3730 19 3 730 26 5x13x5 30s 2 5
13. FW 11 variables like current voltage speed etc when a given event occurs in the system e g alarm fault overload overvoltage etc When a given event takes place the trigger function activates data storage process The stored variables can be displayed in the form of graphs by using the SuperDrive G2 software Trace function simulates a 4 channel oscilloscope It is a very powerful tool to be used on start up procedures of systems and on diagoses of faults E i uu eo H Q s LELIEM bibi ER eet ERRARE Trace function configuration in the SuperDrive G2 WEG SoftPLC WEG SoftPLC is a resource that provides PLC features to the CFW 11 without the addition of any accessories It provides flexibility to the product allowing the user to create his her own application software user s program The SoftPLC main features are m adder language programming using WLP software BM Access to all VSD parameters and Os m Configurable PLC mathematical and control blocks m Application software download upload and online monitoring via USB connection m Storage of user application in the CFW 11 Flash Memory Module see below m Memory capacity of 15kB for storage of a user application Simple and practical programming environment hte oe j maocmcgmcococcooulMk LII LII LLIIJII 3 coammmumroagcgnpona accocomaocoonoui Doar ooo Socios Egrang CEE EE E E I E E E Flash Memory Module m t sto
14. WWW Weg net ueg Variable Frequency Drives ale WEG s CFWA 1 uses state of the art technology to control motors up to 2 600HP Aimed at increasing customers productivity the CFW1 1 offers A the following innovations 3A Gis 4 s Ye 7 Zl A f Applications Standard Features j m Pumps m Same programming as all other WEG VFD s CU m Fans Blowers E Plug and play philosophy connect and use enables quick and easy installation of m Conveyors accessories and options m Compressors E USB for microcomputer connection for using SUPERDRIVE programming and m Agitators and Mixers monitoring software as well as updating inverter firmware m Extruders E Human Machine Interface HMI with backlit graphic display and soft keys greatly m Grizzly Feeders facilitates inverter programming and operation m Centrifuges B DC link inductors symetrically connected to positive and negative DC link m Cranes and Hoists terminals enable compliance with IEC61000 3 12 standard requirements regarding m Rollout Tables harmonics no need for external line reactance B Presses E Intelligent thermal management enables full protection of IGBTs monitoring of B Saws heatsink and internal air temperature B Conformal coated circuit boards B 50 C Ambient Options E Automatic control of the heatsink fan with speed sensor additional protection and E Safety stop in easily detachable from the unit for cleaning and maintenance co
15. accessories and options used enabling easy installation and safe operation while eliminating manual configuration Accessories Name Description Slot IOA Module for CFW11 1 analog input Al4 14 bits voltage or current 2 digital inputs 2 analog I0A 01 outputs A03 and A04 14 bits voltage or 1 current 2 digital outputs open collector All analog input and output are galvanic isolated IOB Module for CFW11 2 isolated analog inputs AI3 and Al4 12 bits voltage or current 2 digital IOB 01 inputs Provides Galvanic Isolation for AO1 and 1 A02 11 bits voltage or current 2 digital outputs open collector All analog inputs and outputs are galvanically isolated l0C 01 8 digital inputs and 4 relays 1 l0C 02 8 digital inputs and 8 digital outputs 1 IOE 01 6 PT100 or KTY 84 thermistor inputs 1 Interface for incremental encoder 5 to 12Vdc awe 100kHz 1 with repeater Interface for incremental encoder 5 to 12Vdc ENGE 100kHz 1 2 RS485 01 Interface for RS 485 serial communication 3 modbus RS232 01 Interface for RS 232C serial communication d CAN RS485 01 CAN interface CANopen DeviceNet RS 485 3 CAN 01 CAN interface CANopen DeviceNet dads DP 01 Profibus DP interface 3 PLC functions IEC programming electronic gear box 9 digital inputs 3 relay outputs 3 digital outputs PLC11 01 14 bit analog input 2 analog outputs with 14 bit 1 2 resolution and 3 2
16. duit Kit for frame size B KN1B 01 82 V1 E Conduit Kit for frame size C KN1C 01 94 Vi iai IP21 Kit for frame size D KIP21D 01 100 V1 EN Power Cables Shielding Kit for frame size A PCSA 01 40 V1 M Power Cables Shielding Kit for frame size B PCSB 01 42 V1 5 Power Cables Shielding Kit for frame size C PCSC 01 45 V1 Power cables shielding kit for frame size D PCSD 01 56 V1 Power cables shielding kit for frame size E PCSE 01 76 V1 External Dynamic Braking Module frame F amp G DBWO3 CFW11 F amp G 6 822 V1 Anybus card goes in slot 4 and allows the user to combine the PLC11 board with DeviceNet Profibus or Enternet IP A 54 1 800 ASK AWEG Data is subject to change without notice Variable Frequenoy Drives CFW11 Accessories and Options Blank cover HMID 01 Blank cover to replace the standard VSD keypad when not used Remote keypad frame RHMIF 01 Frame for Keypad installation on panel door or machine console Degree of protection IP56 CFW11 Dynamic Braking module DBW03 CFW11 F amp G The DBWOS external brake module allows for energy dissipation during regenerative cycles or when running high inertia loads requiring short deceleration times Resistors priced seperately see page A 57 and A 58 This breaking unit was developed especially for VSDs that do not have a built in brake chopper e g CFW11 frame sizes F G and Modular Drive Its voltage ranges from 380 to 480V and its main function is to lim
17. he system The standard CFW 11 can be connected to a DC bus system When required the factory should be consulted for further details Regenerative front ends are also available Note An extra pre charge circuit must be added to each of the VSDs All CFW 11 models from size A to D have optionally braking Functions m Multi speed up to 8 pre programmed IGBT in as standard speeds M CFW 11 size E the braking IGBT is optional built in m PID regulator automatic control of level B CFW 11 sizes F and G Breaking IGBT is optionally with the pressure flow weight etc external DBW module m Ride Through operation during momentary CFW 11 can monitor the temperature probes of the motor PTC Loss of the power supply PT100 KTY84 providing thermal protection to the motor m Skip Frequency rejection of critical or optional accessory is necessary resonant speeds Operating air temperature up to 50 C 122 F for sizes A to D m S Ramp smooth acceleration deceleration and up to 45 C 113 F for size E 45 C 113 F for sizes F and G up to 601A 40 C 104 F for size G with 720A Motor overload protection according to IEC 60497 4 2 and UL 508 C Data is subject to change without notice WEG Automation Products and Solutions A 49 Weg Variable Frequency Drives CFW11 Drive Ratings Normal Duty ND Cycle m 110 for 60 seconds every 10 minutes m 15096 for 3 seconds every 10 minutes Heavy Duty
18. it DC bus voltage in order to avoid tripping the VSD due to overvoltage caused by applications where breaking is required Maximum Output Current 378Amps Minimum Resistor 1 80hms External power supply for fans 220Vca 5969250mA Thermally Protected Safety stop in accordance with EN 954 1 category Ill With the activation of the safety stop function the gate pulses to the IGBTs are disabled With no voltage available at VSD output no torque is applied to the motor This ensures that the motor remains safely stopped Enclosures KN1A 01 Conduit kit frame size A KN1B 01 Conduit kit frame size B KN1C 01 Conduit kit frame size C NEMA Type 1 KN1E 01 Top cover size E models 105 and 142 KN1E 02 Top Cover Conduit kit size E models 180 and 211 KN1F 01 Conduit kit for frame size KN1G 01 Conduit kit for frame size G KIP21A 01 Top cover kit frame size A KIP21B 01 Top cover kit frame size B KIP21C 01 Top cover kit frame size C X Standard N A X X X KIP21D 01 X KN1E 01 KN1E 02 KN1F 01 KN1G 01 Note In the KN1X 01 Conduit kit frame sizes A B and C power cable shielding is also provided Kits KN1F 01 and KN1G 01 are under UL certi cation process Data is subject to change without notice WEG Automation Products and Solutions A 55 Variable Frequenoy Drives CFW11 USB Connection SuperDrive Trace Function Trace function is used to register C
19. mpliance E Normal Duty and Heavy Duty ratings to adapt optimally to all kinds of loads with EN 954 B Protection with failure and alarm warnings 1 category TII E Motor overload protection in compliance with IEC 60947 4 2 UL 508 C m External control feed B Memory card built into the standard product allows user to create functions without with 24 Vdc the need to use an external PLC soft PLC via IEC61131 3 programming software m RFI filter in E Guided start up simplifies initial user programming compliance with EN B Real time clock with time and date stamped fault log 61800 3 internal E RACE SCOPE function to assist with the start up and system diagnostics E DB Resistors B SuperDrive G2 compatible available upon request Factory ordered NA mda uo um N v VAA ITI S038 06 Y TIS Y30 V VJ VA WAH N VJ I E gt antem DI E ELI EXE EE Data is subject to change without notice WEG Automation Products and Solutions A 47 T Bl www weg net Variable Frequency Drives 1 5 to 600 HP Coding 2 3 4 8 0006 T 4 Z 2 Frame Size A B C DorE 0006 6 Amps 0024 24Amps 0242 242Amps 0601 601 Amps B Single phase or Three phase m S Single phase T Three Phase 3 Number of Phase 4 Input Voltage 2 200 240VAC 4 380 480VAC 8 End of Code Z A 48 1 800 ASK AWEG Da
20. res CFW 11 parameters It ensures that the programming will not be lost as there is a backup of the parameters j m t permits the transfer of parameters stored in the flash Memory Module to the CFW 11 and vice versa It is a useful function for machine manufacturers or in processes where parameter settings are repeated Copy Function B t stores the application software generated by the SoftPLC function The Flash Memory Module comes as standard on CFW11 series HN A 56 800 ASK 4WEG Data is subject to change without notice Variable Frequenoy Drives CFW11 DB Resistors 100 Braking Torque 20 Duty Cycle NEMA 1 Enclosure is Motor Volts Motor HP UN L Catalog Number pem eu n List Price prd 1 5 CFW110006B20NIZ CFDB2 125 224 125 12x5x5 12s 520 V1 2 CFW11007B20N1Z CFDB2 95 298 95 12x7x5 12s 749 V1 2 CFW110007T20N1Z CFDB2 95 298 95 12x7x5 749 V1 3 CFW110010S20N1Z CFDB2 63 448 63 12x7x5 749 V1 3 CFW110010T20N1Z CFDB2 63 448 63 12x7x5 749 V1 5 CFW110013T20N1Z CFDB2 38 746 38 12x10x5 941 V1 5 CFW110016T20N1Z CFDB2 38 746 38 12x10x5 941 V1 7 5 CFW110024T20N1Z CFDB2 26 1119 26 12x13x5 1 130 V1 10 CFW11028T20N1Z CFDB2 19 1492 19 12x16x5 1 322 V1 N 10 CFW110033T20N1Z CFDB2 19 1492 19 12x16x5 1 322 V1 T5 CFW110045T20N1Z CFDB2 13 2238 12 6 2 238 19x10x5 12s 1 644 V1 20 CFW11005
21. ta is subject to change without notice WWW Weg net IT BI Variable Frequenoy Drives CFW11 Technical Features Built in DC link Reactor m Allows the VSD to be installed in any network there is no minimum impedance restriction m Typical power factor PF for rated condition 0 94 for models with three phase supply 0 70 for models with single phase supply m Displacement Power factor gt 0 98 m Meets the 61000 3 12 standard related to low order current harmonics in the network Intelligent Thermal Management m Monitoring of the heatsink and internal air temperatures of the electronic boards provide total protection of the IGBTs and the CFW 11 as a whole m he heatsink fan is turned on and off automatically depending on the temperature of the power modules m he speed and the number of hours of operation of the fan are monitored and indicated in corresponding parameters Alarm or fault messages are generated related to these variables m he fan is easily removed for cleaning or replacement Common Bus available Usually used in multi motor systems common DC bus confguration is a good solution for energy savings In this confguration individual VSD rectifer bridges are replaced with a common input rectifer unit Each VSD is then directly fed from the DC bus to its DC link terminals This solution allows the energy in the DC bus to be shared among the VSDs connected to it thus optimizing the power consumption in t
22. uilt in Braking methods Dynamic braking option 100HP and up DC braking Efficiency Greater than 97 Degree of protection Possibility of flange mounting Overload Analog inputs Analog outputs Digital inputs Relay outputs Transistor output Motor thermistor Supply 24Vdc available for user Certifications Data is subject to change without notice NEMA for models A through E IP20 finger safe for models F amp G Available in all standard models rear part of heatsink with IP54 degree of protection Normal Duty 110 60s Heavy Duty 150 60s 2 differential resolution 11 bits signal 0 to 10V 0 4 to 20mA 2 non isolated resolution 10 bits 0 to 10V 0 4 to 20mA 8 optoisolated bi directional 24Vdc 1 reverse contact output NO NC 240Vac 30Vdc 0 75 A Transistor output 4 isolated output 24Vdc amp 100mA PTC PT100 KTY84 use 1 analog output programmed for contstant current 1 analog input programmed for voltage 24Vdc 20 500mA IEC 60146 Semiconductor convertors UL508C Safety for power conversion equipment EN 50178 Electronic equipment for use in power installations EN 61800 2 General requirements adjustable speed electrical power drive systems EN 61800 5 1 Safety requirements adjustable speed electrical power drive systems EN 61800 3 EMC product standard including specific test methods adjustable speed electrical power dri
23. ve systems EN 60204 Electronic equipment of machines RoHS and WEEE Guidelines WEG Automation Products and Solutions A 59 Weg Variable Frequency Drives Communication Options amp Superdrive Profibus Modbus and Device Net Description Catalog Number List Price pes SUPERDRIVE Software USB Cable SUPERDRIVE USB 301 V1 SUPERDRIVE KIT CFW08 KCS CFWO08 RS232 PC Cable CD Software KSD CFWO08 97 V1 SUPERDRIVE KIT CFW09 KCS CFWO09 RS232 PC Cable CD Software KSD CFWO09 156 V1 SUPERDRIVE G2 KIT SSW06 KSDG2 SSW06 62 V1 SUPERDRIVE G2 KIT SSW07 KRS 232 SSWO07 CAB RS 3 CD Software KSDG2 SSW07 225 V1 RS 232 485 Converter mounted externally MIW 02 221 V1 RS 485 Kit for PC 417102506 900 V1 Communication Options The table below shows the hardware options required to provide WEG VFD s and Soft Starters with different serial communications or networking capabilities RS 232 RS 485 Profibus DP DeviceNet Modbus RTU KCS CFWO8 KCS CFWO8 CFWO08 KCS CFWO08 KCS CFW08 MIW 02 MIW 02 MIW 02 KCS CFW08 MIW 02 MFW 01 PD MFW 01 DN CFWO09 See CFWO9 accessories CFW11 See CFW11 accessories MIW 02 MIW 02 MIW 02 MFW Pss Sada wid MFW 01 PD MFW 01 DN 01 MR MIW 02 MIW 02 MIW 02 MFW salads planta de MFW 01 PD MFW 01 DN 01 MR MIW 02 MIW 02 MIW 02 MFW ones standard MI O MFW 01 PD MFW 01 DN 01 MR SSWOG Standard KRS 485 SSwos KFB PD SSWO6