User Manual GSM Alarm System
Contents
1. Factory Reset Then you will see there are two options Restore Defaults and Format System Restore defaults Except Remote controller Sensors Wireless Siren RFID tags and Bluetooth communication the rest of system settings are returned to default status Format System All the system settings are cleared About System System information can be checked by following the steps Disarm the system and enter Menu Program System About then we can see a menu as bellowing picture Version Production Date MERIETE i IMEI Bluetooth Mac Version Software version Production Date The date of Manufacture Manufacture By The Manufacturer IMEI a15 digits number the symbol of legit networking access Bluetooth Mac Bluetooth address a series of number generated by system automatically The number will be needed when pairing the cell phone with alarm system via Bluetooth Hardware Test This auto trouble shooting feature enables users to rule out the failed parts by themselves in event of system failure Disarm the system and enter into Menu Program Hardware test page up and down we will see whole menu Lcd Test Led Test Key_Test RFID Test Voice Test Record Test RF Receive Test RF Send Test Battery Test Power Off Test Call Test Net Central Test Wired Zone Test Bluetooth Test Lcd Test Test whether the LCD scr
2. Program Delete Select a remote controller Select YES and press Delete c Rename amp Record a remote control Remote Controllers Sensors RFit BACK ma PVN Ei Rename Enter into Program Remote controllers Edit Select the one remote control you want to edit Select Edit Owner Name Input the new name and Save Record Recording the name of a remote control is meaningful Once the SOS key on remote controller is triggered the system will dial the preset phone number immediately and the recording will be played when the emergency call is answered Follow the first 4 steps of Rename Select Record Owner Name Record and Enter and then you will have 5 seconds to recording the name of this remote control Wireless Sensors a Addasensor into system Rename amp Record The system is able to connect with 50 wireless accessories not including remote control RFID tags and wireless siren Here are steps Enter into Program menu Sensors Add Trigger sensor remit a signal to panel Input the name of the sensor on the keyboard and Save Recording the sensor name in 5 seconds Each step has to be followed by Enter to confirm your operation b Wireless sensors Auto Search The system can identify the sensor name and location automatically Enter into Program Sensors Edit Auto Sea
3. Here are the operation steps Program Phone Numbers Edit Select a phone number YES Save d AddaSMS number into system Enter into program menu SMS Numbers Add Select Phone Input numbers and press Save The system can store 3 SMS numbers and each SMS number is equal to or shorter than 22 digits Phone os Phone Numbe SMS Numbers BALM wig DOWN a e Arm Disarm notification Default set is YES Every time we arm disarm the system it will send a message to preset SMS phone numbers Choose No will turn off the notification message Program SMS numbers Arm Disarm notification Yes No Remote Control In order to protect people on life threaten occasions to press SOS button on remote controller will not trigger alarm but system will make emergency call and send SMS a Addaremote control into system This system can register with 8 remote controllers and each of them can be renamed Besides the name of remote control can be recorded Here are the steps Enter into Program Select Remote Controllers Add Trigger the remote controller by press any key on remote controllers Input any name you want to identify the remote controller Record the name of remote controller Each step has to be followed with Enter to confirm your operation b Delete a remote control Enter into
4. Input an automatic system arming time in 24 hour format HH MM and press Save The preset system arming time should be any value between 00 00 and 23 59 es Set Arm Time Set Disarm Time Disable i 23 59 Use the same method to set an automatic system disarming time Delay arm disarm It s a very practical function in daily life We suggest setting a 40 s delay for system arming Particularly when you firstly get your alarm system on hand and not so familiar with the features and function it s easy to trigger the alarm It s highly recommended to set a delay time for system arming Then there will be a plenty of time to fix the false alarm How to set the delay time Disarm the system and enter into Menu Program System Settings Arm delay time Input a number between 1 and 999 as bellowing picture and Save Password Input 1 999 Seconds Arm Delay Time Alarm Delay Time LUP Use the same method to set the system disarm delay time Door Window Open Reminding With this feature the system cannot be armed if any single one of door window sensors is not closed The system will remind you to keep all the windows and doors closed before leaving the house and arming the system Here are the setting steps Disarm the alarm system and enter into Menu Program System Settings Door Window Open Tip Select YES Change a system language Dis
5. You will see 66A bluetooth device on your searching results Select it and the cell will pop up a dialogue with Device name and Passkey At the same time panel will pop up a dialogue with the same Passkey and your cell brand select Accept on the alarm panel To par witty GA Make ure it is showang thes panske 959896 cad Poe Mobile interface Alarm Panel interface At last you will see a Bluetooth mark on the panel LCD screen Pairing completed Yul CT System Disarmed 01 04 2014 15 38 MENU Monitoring Center The alarm system use standard Ademco Contact ID to connect with monitoring center Get a telephone number and User ID from your monitoring service provider and input them into the alarm system And make sure turn on the upload alarm data and upload ARM Disarm data Then the monitoring center can watch your property right away Here are the operation steps Disarm the system and touch Menu Enter into Program Monitoring Center page up and down on the panel and you will see a whole menu for monitoring center as bellowing picture Monitoring Center Number ADEMCO Contact ID Upioad Alarm Data Upload Arm Disarm Data Monitoring Center Number the system can accept 2 monitoring center phone numbers at most Make sure that the mobile number is no longer than 20 digits ADEMCO Contact ID it is composed of 4 digits of numbers which is authorized and designated by the
6. monitoring service provider Upload Alarm Data select YES then the system alarm settings will be uploaded to the monitoring service provider Upload Arm Disarm Data select YES the system ARM DISARM data will be sent to monitoring service provider automatically Outgoing Message In event of intrusion this message will be sent to preset SMS numbers If you also record the message the record will be played to preset Phone Numbers before the emergency call is answered a Edit the message Disarm the system enter into Menu Program Page down and select Outgoing Message Edit Text Message Input the message on alarm panel and Save The message should be shorter than 25 letters and symbols Enter Text Message Lucy and David Home SAKE b Record the message Disarm the system and enter into Menu Program Outgoing Message Record The record should control within 10 seconds The system will count down from 10 when doing the record Record Recording Pla y Delete c Delete the message Disarm the system and enter into Menu Program Outgoing Message Delete Timely arm disarm system The menu can realize system automatically arm disarm itself on a setting time How to set the automatic system arm disarm time Enter into Menu Program Timely Arm Disarm Enable Set Arm Time
7. siren Siren Sound Duration Set siren sound duration from 1 180 seconds Program Wireless Sirens Duration Input a number between 1 to 180 and Save Arm Disarm wireless siren notification Program Wireless Sirens Arm Disarm Tone Select Yes to turn on the notification long beep then users will be well informed when the wireless siren is arm or disarmed or Select No to turn off Encrypt Encrypt the wireless siren can obviously reduce the false alarm Enter into Program Wireless Sirens Encryption Input 4 digits encryption number as bellowing picture indicates and press Enter Important notice for encryption 0000 and 5555 are not allowed and will be considered as error data One group of 4 digits encryption number is unique to one wireless siren Enter 4 Digits Encryptio Bluetooth Communication between panel and cell There are two way to connect the cell with system via an APP Bluetooth and GSM network Within Bluetooth range we can use Bluetooth to realize basic control of the system Out of Bluetooth range App will choose GSM network automatically 8 cell numbers can be paired with system via Bluetooth Format the system will disconnect all the paired mobiles How to connect your cell with system via Bluetooth First of all be familiar with Bluetooth menu within system Disarm the system enter into Menu P
8. User Manual GSM Alarm System All rights reserved by Delta Security Co Ltd Dear Clients Thank you for using our GSM Alarm System We are committed to giving you the best home security available today and we take the safety of your home and family seriously Our system allows you to instantly arm and disarm your property instantly change your system settings and find out your system status and much more At safety concerns we encourage you to change the default password as soon as you get your system set up This guide will walk you through the easy set up of your system We ve started with already customizing and turning your system to your specifications so everything is ready to go when you open the box Please keep this instruction manual in case you may read it at any time in the future Thanks again for choosing our products and service Tx 5 a System Disarmed 2004 01 01 22 13 OOO O OOY O 000e Cautions To avoid personal inquiry and the damage to the product please take the following preventive measures Input Voltage DC12V 1A Do not use power adapter with different specifications e Use the professional tools for assembling to avoid the damage to the main panel Press the touch keypad lightly Keep it away from the moist environment and flammable explosive environment Keep the product dry and clean An ideal place to mount the panel should be under the minimum RF signal interfere
9. arm the system and enter into Menu Program System Settings Language page down and select one language For now we have English only and more languages will be added into system later Change a password Disarm the system and enter into Menu Program System Settings Password Conform you r Old Password and press Enter Input a new 6 digits password and press Enter input the new password to confirm and press Save It s highly recommended to change the password as soon as you get your alarm system System date and time Take out the battery will erase customized date and time setting and return back to factory set Disarm the system and enter into Menu Program System Settings Date Time Date Display Format Select one format and press Save and then press Back to return to former dialogue select Set Date input date according to previously saved date format and press Save YYYY MM DD Year Month Day System time setting Menu Program System Settings Time input a time in 24 hour format and press Save Blank will be considered an error data Restore factory set It may lead to the lost of all the customized system settings Be careful to operate it unless you have to Enter into Menu Program System Settings
10. een can work normally Led Test Test whether Led Lights and the backlights can work normally Key Test Test whether the keyboard can work normally RFID Test Test whether the RFID Reader area can work normally Voice Test Test whether the Voice Prompts is Accurate amp Complete Record Test Test Whether the Host can record normally RF Receive Test Test if the Host can receive the Wireless Sensors Detectors signal RF Send Test Test if the Host can send the signal normally Battery Test Test if the back up Battery power works normally Power Off Test To test if the power adapter can charge the Host normally Call Test To test if the Host can receive the calling amp act according to the instructions Net Central Test To test if the Host can connect to the Monitoring Center Normally Wired Zone Test To test whether the wired defense zone work normally when triggering Bluetooth Test To test whether the Host can scan the other Bluetooth devices normally 4 How to remote control the alarm system via phone call or SMS By phone call or sending SMS we can realize basic control of system a Remote control by SMS Make sure your SMS phone number is preset on your alarm system Otherwise the alarm system will not accept your instruction Edit SMS with content 8888881 to Arm the system Edit SMS with content 8888882 to Disarm the system Edit SMS with content 8888883 to
11. enter into Home mode Edit SMS with content 8888884 to inquire system arm disarm status 888888 is system default password If the password has been changed replace it with new password b Remote control by Phone call Make sure your phone number is preset on your alarm system Otherwise the alarm system will not accept your instruction Dial the phone number of your alarm system and you will hear a voice Please input the password Enter the password Default 888888 on your mobile phone and then there will be another voice instruction Please input the instruction Now press Number key 1 to arm the system Number Key 2 to disarm the system Number key 3 to monitoring and listening to the alarm site for 30 seconds If continuous monitoring is required press 3 key again to extend time for 30s All rights reserved by Delta Security CO Ltd
12. iating image Yul om System Disarmed 01 04 2014 15 38 MUTE MENU Function Key Program Chime Alarmed Record uP DOWN SAVE Save up the settings ABC abc 123 Switch the input method DELETE Delete the inputs Start to Set Before doing any settings we need enter into setting status or enter into Program menu Please follow those steps Each step within this manual has to be followed with Enter to confirm your operation Disarm the system Press Menu Select Program Input password default value 888888 Start Menu o System Disarmed 01 04 2014 15 38 Program Chime Alarmed RO org Program Start to set the system Chime Turn on off the doorbell Function Alarmed Record Record alarm events Event Check out details of opening the door each time Add a Phone number SMS number a Adda phone number into system Enter into program menu Select Phone Numbers and Enter Select Add and press Enter Input numbers on the keyboard and press Save The system can store 6 phone numbers and each phone number is equal to or not longer than 22 digits RFIC Program W hime J F S sirens Phone Numbers We IDOVEN b Delete a phone number from system Program Phone Numbers Delete Select the phone number YES Delete c Auto Login phone number This number can access to the system without password
13. in normal zones are armed Chime Zone Turn on off the chime function Delayed Zone Delay the system alarm We can program the delay time at Menu Program System Settings Alarm Delay Time Siren Enabled Turn on off the siren in event of being triggered Delete Delete the Sensor RFID tags a Adda RFID tag into your system The system can accept up to 8 RFID tags Enter into Program and press Enter Select RFID and press Enter Select Add Hold your RFID tag and make it close to RFID reading area as bellowing photo The system will generate a code automatically At this time press Enter and system will ask you to add a name for this RFID tag Add a name and save it Add RFID Trigger RFID Code 0007673841 LBACK b Rename a RFID tag If you want to change a name for your RFID tags please follow the steps Enter into Program Edit Select one RFID tag listed on your system from Card 01 to Card 08 and press Enter Input a new name and Save c Delete a RFID tag Enter into Program RFID Delete Select the RFID tag you want to remove and press Enter Select Yes Delete d Arm Disarm Send SMS YES NO Enter into Program RFID ARM Disarm Send SMS YES NO YES Each time system arm disarm by RFID tag there will be a notification SMS to preset SMS
14. nce and the center of all defense zones generally living room Please change your password default 888888 as soon as you get this alarm system To obtain a high quality intercom voice it is highly suggested to keep a 35cm distance to the Mic Features 1 Ultra thin design 14mm thickness 2 Menu user interface easy and comfortable 3 SMS Bluetooth communication 4 Mute Volume up Down 5 RFID function 6 Up to 50 wireless and 2 wired defense zones each zone can be edited including rename delay siren off set up as home zone etc 7 Door sensor auto search manual search 8 Authorized priority phone number in order to fast access to panel without password 9 Low battery reminding 10 Support CID 11 Chime function 12 USB port to upgrade your software online 13 Built in engineering model easy trouble shooting 1 Alarm Host Diagram GSM signal indicator Flash once every second when no SIM card or searching network Flashes once every 3 seconds when GSM signal is in normal GSM Signal Indicator LCD Screen RF Signal Indicator Ld v v e System Disarmed 20040101 22 193 e e Start Menu Y lt e Arm a lt e Home Arm P lt Disarm lt Emergency SOS gt RFID reading area A a switch Arm Arm the system by panel has a 60s delay Default factory set Home mode Enter into home mode All sensors in Normal Zone are armed except those in Home mode zone which are disarmed
15. phone numbers No system arm disarm by RFID tag will not notify preset SMS phone numbers Wireless Siren a Adda wireless siren into system The system can register 3 wireless sirens at most Here are the operation steps Enter into Program Wireless Sirens Add then you will see a default name Sirens 1 onthe LCD screen press Enter as bellowing picture indicates Then system will imply that Put Siren in Setting Mode How to put siren in setting mode Set Button is E Indicating 4 Otome we 3 2 1 Plug in the wireless siren into power jacket and you will hear a strong beep from siren Press the black button on left side of siren for four times and you will see the four indicating lights on The wireless siren goes into setting status Now focus back onto panel signal indicator flashes and panel sends signal to wireless siren automatically You will hear a long beep from wireless siren as a response Add successful b Rename a wireless siren Enter into Program Wireless Sirens Edit Select one siren Edit Name Input a new name and Save c Delete a wireless siren Program Wireless Sirens Delete Select one siren and Delete Yes Delete Turn on off the Siren Program Wireless Sirens Siren Enable Select Yes to turn on siren Select No to turn off
16. rch Sensors Trigger the sensor and the system will display the sensor name on screen c Wireless sensors manual search The sensor name and location can be found manually Here are the steps d Edit Sensor Each sensor within the system can be edited with different features and functions Identify the sensor s name by either way of above two methods press Enter to confirm Edit Zone Name Record Zone Name Auto Search Sensor Emergency Zone Trigger The Edit Sensor N 6 lame TENA atts k Chime Zone DIJES my Aelal Siren Enabled Edit the Zone Name Sensor name has to be controlled within 25 letters When panel receives an intrusion signal from this sensor panel will report all your programmed information to owner by SMS It s highly suggested to program the name with much more information Then the owner will be well informed in event of intrusion For example PIR in living room can be named PIRO1 living room Record Zone Name Record the sensor name within 5 seconds The system will count down from 5 The record will be played when the emergency call is answered Same as zone name it s highly suggested to record as much information as possible Emergency Zone The alarm will be triggered in event of intrusion even the system is in Disarm Home Mode status Home Zone YES Homezone No Normal zone At home mode all the sensor being preset as home zone will disarm and those
17. rogram Bluetooth Settings Bluetooth On Off Name 66A Visible Delete Paired Mobile Host Mode Bluetooth On Off make sure it s on and then the cell is able to detect it Name we can change a name for Bluetooth one easy to remember Visible choose YES the device can be detected In avoid of malicious pairing choose No after you finish pairing with your own mobile Delete Paired Mobile remove existing registered mobile number from system Host Mode Searching Bluetooth Devices Second install and run the APP provided by Manufacturer on the mobile If it s your first time to run the APP select a proper language The cell will request if activating the Bluetooth function and select YES Otherwise activate your Bluetooth function on the cell manually Add Host name host phone number and bluetooth Address as APP indicates on Cell phone How to find out Bluetooth Address of your alarm panel Disarm the alarm system Program System About BlueTooth Mac and press Enter then system will generate a BlueTooth Mac Address automatically as belowing picture The BlueTooth Mac is random and unique Input the same address on Cell phone and save BlueTooth Mac 2c 01 26 35 62 60 And then Input the correct password of host default 888888 on cell and save Third pairing the cell with alarm panel via bluetooth Initiate the search of Bluetooth Device on the cell
18. so that users can move freely at home Disarm could be done by keypad or RFID tags or Remote controllers Emergency SOS Go into emergency status Tamper Switch Land Wire Slot MIC SIM Card Siot Battery Case r 1 Upgrading switch 2 Power switch Interface for the wired Defense Zones Debugging Loudspeaker interfacev USB Slot Debugging interface Software calibration for manufacture use only Interface for the wired defense zones port for wired accessories excluding wired siren Upgrading switch software online upgrading 2 Start Up a Insert a SIM card Insert a SIM card in direction as above pictures indicate Push until you hear a click of spring Do not insert or take out the SIM card when the main unit panel is powered on b Connect wired accessories with Panel The panel supports 2 wired accessories excluding wired siren There is a cable within the package with one side connecting panel and another side having 4 wires in different color and n j 2 Wired Zone 1 Wired Zone 2 connecting 2 wired accessories c Power on Connect the power adapter to POWER port on back of the console Route the power adapter 12V 1A cord through the channel toward the side of the console Plug the power adapter into nearby electrical wall outlet that is not controlled by a switch Keep the Power Switch at ON position for internal backup charging 3 Operation Instructions Init