1.  clear  key to finish the calibration  Then LED display will show  CALL   and the actual calibrated temperature after 3 sec    Calibration at High Temperature  when the unit is being heated and reaching the setting  temperature with stability then press  lt     gt  at the same time until LED display shows   150 0 Then press A or y to input the Calibrated temp  and then press  clear  key to finish  the calibration  The LED display will show  CALH  and the actual calibrated temperature    after 3 sec     Warranty   We guarantee the perfect functioning of this instrument against defects in material  design   and workmanship  when use under appropriate conditions and in accordance with the  instruction manual for a period of TWO YEARS from the date of initial shipment    This warranty covers all parts and components of the instrument except those normally  requiring frequent replacement  such as tubing  gasket  O rings  etc  We will not be liable for    any personal injury  misuse  improper maintenance  negligence or accident     Product Liability    Under no circumstances shall Wiggens be liable for indirect  consequential or otherwise  special or unrelated damages of any kind    Wiggens reserves the right to make technical changes without prior notice    Email  info wiggens biz    Web Site  www wiggens com    V1 1 11052013 WIGGENS WD325   7    
2. COD Reactor    WD325       WIGGENS labortechnik GmbH  M  hsamstrasse 3610249 Berlin Germany    Fon  49 3042105470 E Mail iinfo wiggens biz WIGRENGS  Fax  49 3042105971 Web www wiggens com 10    COD Reactor  WD325    Congratulations    You have made an excellent choice    WIGGENS wants to thank you for the trust you have placed in us    This operating manual has been designed to help you gain an understanding of the  operation and possible applications of our instruments  For optimal utilization of all functions     we recommend that you thoroughly study this manual prior to beginning any operation     The WIGGENS Quality Management System        CRS CERTU 180 9001  u 150 9001 Certificate Registration No  01 100084841       Unpacking and Inspection    Unpack the instruments and accessories and inspect them for possible transport damage   Damage should be reported to the responsible carrier  railway  or postal authority  and a  damage report should be requested  These instructions must be followed fully for us to  guarantee our full support of your claim for protecting against loss from concealed damage     The form required for filing such a claim will be provided by the carrier     Printed in Germany Changes without prior notification reserved    Important  keep operating manual for future use    2   WIGGENS WD325 V1 1 11052013    Contents    Unpacking and checking    A A dee A A AD 4  7  8167 2121210  9  T PPNRERRRERPERRRRENESRORRERTRERURERTRENERENPRRNRENERENERENERENERENEREN
3. ERENERENERENRENERENERENERENEENERENEREREREREREIRNGR 4  InStal ao e Ii DD RR RR 4  FPUNCUONS sat ccs ce tate ta tea it ear en ar AA eer a OR 4  Operating PTI CEUTA a Ein 5  MV ANT ANDY  s 7  Prod  ctHiability  sce OS 7    V1 1 11052013 WIGGENS WD325   3    Unpacking and checking   Before unpacking this instrument  please check first the packing case is complete without   any damage  After unpacking  please check the accessories are complete as listed also  If  there is any problem with the unit  please keep the serial number along with packing case   and contact your local distributor for replacement immediately    Please dispose of the packing materials in compliance with your local environmental    protection policy     Accessories     gt  Power cord X1   gt  User Manual X1    Installation  Before installation  please ensure the voltage  current and frequency of your socket fit in with  the unit  The related information can be found at the back of instrument  The socket should    be connected to earth for safety     Functions    1  On Off  power switch    2   lt   operating mode selection    3  A Vset temperature or time value   Press the button once  the value will increase or decrease by one unit and keep pressing  the button  the value will change fast  clear  pressing clear button will zero the  temperature setting when setting the temperature valve and make the time setting  unlimited  When setting the time valve  start stop  after setting time and temperature  valve  pr
4. able range  ambient temp    5  C 200  C  When the setting valve is  0   the LED display will show  OFF  rather than   0  show  OFF  rather than  0   Press  clear  key to zero the setting valve   Press  start stop  key to start heating  when the heating temp  reaches up to 70  C then SSS  light begins flashing   When the heating temp  reaches the setting temp  then the timer starts  counting down  if the timer has a setting valve  until the setting time is finished then the unit    will beep for 10 sec  to warn operator and stop heating automatically     V1 1 11052013 WIGGENS WD325   5    COD Mode    The default heating mode is COD  If you need to digest samples in COD mode  please press  Start Stops button to start operation  WD325 will start to heat to 150  C and start timer for  120 minutes  The LED Display will indicate the remaining time  When time is finished  the  alarm will beep for 10 sec    COD mode is the only mode that will light COD and PT indicators     Time setting   Shift the indicator to timer by pressing  lt  or  gt  then pressA V to set the desired time     The time will be unlimited if pressing  clear  key     Extra Program Setting  P1  P2  P3     P1 When turning on the unit  COD indicator lights up then press  clear  key and  lt   key at the  same time for around 3 sec    P11  will show on LED and release the keys then 100 0    Default Heating Temp   will show on LED  Reset a new heating temp  by pressing A or y  key and then press  clear  to finish settin
5. ess this button to start and stop the operation by pressing it again cod indicator   when the power switch is turned on  the default operating mode is cod  then press    start stop button  the unit will start heating up to 150  C and start timer for 120 minutes     4   WIGGENS WD325 V1 1 11052013    The LED display will indicate the remaining time instead of the current temperature   When the setting time is finished  the unit stops heating and the alarm will beep for a few  seconds    st  when st indicator is fight  the temperature can be set by pressing Aor V   timer  when timer indicator is fight  the time can be set by pressing A or y   pt  when pt indicator is light  the LED dispaly indicates the actual temperature     heating  when the indicator is light  the unit is being heated     Oy et ee chs a    hot top  when the temperature is over 70  C  the indicator will flash to warn user not to  touch    9  alarm  when the temperature is over 210  C  the unit will shut down automatically and the  alarm indicator will light to warn       gt  In STOP condition  all setting and display functions are feasible     Operating Procedure   Ensure that the power cord is connected with socket before operation    Switch on  then the COD indicators    lights    Temperature Setting   When the LED light shifts to  st   set temp    the LED display will show the last temperature  setting valve  Press A or V to change the setting valve   Effective setting valve within 0  C 200  C  actual work
6. g  After    P12    has shown for 1 sec  then 30  Default  Heating Time  will show on LED  Reset a new heating time by pressing A or V key and then  press clear key to finish setting  Then LED will show COD    P1    setting is finished    P2  Follow the above same steps to reset P2 program by pressing  clear  key and   gt  key   P3 Follow the above same steps to reset P3 program by pressing  clear  key and D key     The P1  P2  P3 will display the last setting valve instead of the default valve after rebooting     Extra Program Execution  P1  P2  P3     When turning on the unit  COD shows up on LED  press  clear  key and  lt  key at the same  time for less 3 sec  then  P1  shows up on LED  press  clear  key and   gt  key at the same  time for less 3 sec  then  P2  shows up on LED  press  clear  key and A key at the same  time for less 3 sec  then  P3  shows up on LED    When  P1  shows up on LED then press start stop key to run P1 program     Follow the same steps to run P2 or P3 program     6   WIGGENS WD325 V1 1 11052013    Temperature Calibration    When LED light shifts to    pt    indicator  LED display will indicate the actual heating  temperature then A y  Clear  keys are all ineffective    Calibration at Ambient Temperature  press  lt  or   gt  select  pt  indicator   then LED display will indicate the present ambient temp  Press  lt     gt    at the same time for 3  sec then LED display will show  30 0   Then press A or V to input the present room  temperature  press 
    
Download Pdf Manuals
 
 
    
Related Search
 English  english to spanish  english to russian  english to french  english to japanese  english to german  english  english to korean  english to tamil  english to spanish translation  english to italian  english to chinese  english to hindi  english to tagalog  english to marathi  english to latin  english to arabic  english to tagalog translator  english bulldog  english to telugu  english to vietnamese  english to spanish google translate  english to polish  english alphabet  english breakfast  english language 
    