Home

SR2 manual - DoorEntryOnline.co.uk

image

Contents

1. data transfer connection 1 x power supply and 9 x SR2 units To 12V To GND i Red A gt Black To additional SR2 units Green DO gt White D1 O Set User Data Transfer Programming Step Remote Control Operation 1 Enter Program Mode Master Code 2 Set Transfer Data on the first SR2 96 For all 1000 users this will take 3 minutes Within 3 minutes the green LED will shine after 1 x bleep the LED will turn red to confirm data transfer PROGRAMMING Programming will vary depending on access confirguration Follow the instructions according to your access configuration General Programming I nformation Two ways Remote Control Please use the Infrared Remote Control to program the Reader The infrared receiver head is near the LED so when you program the reader please direct the Remote Control to the LED UserID number Assign a user ID to the access card in order to track it The user ID number can be any number from 0 997 IMPORTANT User Ds do not have to be proceeded with any leading zeros Recording of User ID is crucial Modifications to the user require the User ID to be available Proximity Card Any 125KHz industry standard 26 bit EM and HID Proximity card or key fob Sound and Light indications Operation Status redcoour ouzer sany Sid Reig bight operation enor o The beeps Please see Reset Procedure for ALARM Enter and Exit Program Mode Via the Remote Control
2. DC Proximity Card Reader EM amp HID Radio Technology 125KHz Proximity Card Read Range 2 6cm Wiring Connections Relay Output Exit Button Relay One NO NC Common Adjustable Relay Output Time 1 99 Seconds 5 seconds default Lock Output Load 2 Amp Maximum Environment Meets P66 Operating Temperature 40 C 60 C Operating Humidity 20 RH 98 RH Physical ABS Shell Colour Black Dimensions H 102 W 48 D 20mm Unit Weight 150g Shipping Weight 250g Package Contents C SR2 Card Reader Infrared Remote Control Manager Delete Card Manager Add Card Manager Cards amp 10 user cards or key fobs Diode IN4004 For relay circuit protection edie Sedie Self Tapping Screws 3 25mm a Wall Anchors 2 Screw Driver INSTALLATION e Remove the back cover from the unit e Drill 2 holes A C on the wall for the screws and one hole for the cable e Knock the supplied rubber bungs to the screw holes A C e Fix the back cover firmly on the wall with 4 flat head screws e Thread the cable through the cable hole B e Attach the unit to the back cover z a im Sees P om at E Wiring cable Red o O Power 12 28 Vots ACDC Power input Bue o o o T Normally open relay output Connection Diagram Examples Common power supply for magnetic lock Fail open power to lock EN YN YN CoN E Yy f N 12v or 24v DC PSB 1 Open C NO N C 12v or 24v DC Power Supply Cor1
3. DEO SR2 Proximity amp Wiegand Card Reader with Remote Control User Manual INTRODUCTION The SR2 is a compact weather resistant multi function card reader that can be used as a standalone programmable access control card reader as well as a Wiegand output card reader providing proximity entry for up to 1000 users 998 common users and 2 panic users PIN access is also possible via the remote control unit for the Administrator and all user data can be transferred from one unit to another within 3 minutes Maximum connection is 10 units It reads both EM amp HID card or key fob It uses Atmel micro controller to ensure maximum performance in any environment and the low power circuit makes its service life prolonged The SR2 s unique feature is simple in design easy to operate program and high reliability Features e Weather resistant to IP66 e Reads 125KHz EM amp HID card or key fob e One programmable relay operation e Pulse mode Latch mode relay operation e Remote infrared programmer e Master Add Master Delete cards e 1000 users 998 common users amp 2 panic users e User data can be transferred from one unit to another e Wiegand 26 37 bit input amp output e Card block enrolment e Tri colour LED status display e Built in light dependent resistor LDR for anti tamper e Buzzer for audible or silent mode e Low temperature resistance 40 C Specifications User Capacity 1000 Operating Voltage 12 24V AC
4. N C or 3 PRESS Lig TO EXIT L2 240v 5 amp Fused Spur Supply Ensure magnetic lock is set to 12v or 24v dc operation before testing Optional exit button Common power supply for lock release Fail secure power to unlock N VY V V VY N 8e J cic JN enyire JK Bic AQeara 12v or 24v DC PSB 1 JOpen C NO N C 12v or 24v DC Power Supply PRESS Ej TO EXT L2 240v 5 amp Fused Spur Supply Ensure lock release is set to 12v or i 24v dc operation before testing Optional exit button Common power supply for auto gate controller using Normally Open contact LNY Y Y VY VY Reed 2 Neoy Nurs Bue Nrang 12v or 24v DC PSB 1 Open C NO N C 12v or 24v DC Power Supply 240v 5 amp Fused Spur Supply To gate controller TO EXIT Optional exit button Attention Install a 1N4004 or equivalent diode across the locking device when using a common power supply to prevent any back E M F as the reader might damage 1N4004 is included in the packing Connection to standard Wiegand controller or PC access control system To enable the SR2 to operate as a Wiegand card reader enter program mode 1234568 3 Set Operation Mode Stand alone or Wiegand Default is stand alone 1 Enter Program Mode Master Code 2 Stand alone Operation 72 is factory default for stand alone 3 Wiegand Reader Operation 73 4 Exit Program Mode User
5. Programming Step Remote Control Operation 1 Enter Program Mode Master Code Factory default is 123456 2 Exit Program Mode Set New Master Code Via the Remote Control 1 Enter Program Mode Master Code 2 Enter New Master Code O New Master Code Repeat New Master Code Set Operation Mode Stand alone or Wiegand Default is stand alone Programming Step Remote Control Operation 1 Enter Program Mode Master Code 2 Stand alone Operation 72 is factory default for stand alone 3 Wiegand Reader Operation 73 4 Exit Program Mode Set User Data Transfer Via the Remote Control Programming Step Remote Control Operation 1 Enter Program Mode 2 Set Transfer Data on the first SR2 For all 1000 users this will take 3 minutes Master Code 96 Within 3 minutes the green LED will shine after 1 x bleep the LED will turn red to confirm data transfer Add User Cards Via the Remote Control Programming Step Remote Control Operation 1 Enter Program Mode Master Code 2 Add Card Using Auto ID number Allows the SR2 to assign Card to next available User ID number OR 3 Add Card Select Specific I D number Allows manager to define a specific User ID to associate the card to OR 4 Add Card by Card Number OR 5 Add Card Block Enrolment Allows the master card to add up to 998 cards in a single step this takes 2 minutes 1 Present Card Repeat Step 2 for a
6. arm will engage after 10 failed card attempts Default setting is OFF The strike out alarm can be set to deny access for 10 minutes after engaging or it can be set to disengage only after presenting a valid user card or Master code 1 Enter Program Mode Master Code 2 Strike Out OFF 60 factory default OR 3 Strike Out ON 6 1 Access will be denied for 10 minutes OR 4 Strike Out ON Alarm 62 Set alarm time 5 0 30 factory default is 1 minute Enter Master code or valid user card to silence 5 Exit Program Mode Set Audible and Visual Response Via the Remote Control Programming Step Remote Control Operation 1 Enter Program Mode Master Code 2 Control LED OFF 70 ON 71 OR OFF 74 ON 75 3 Control Sounds Factory defaults are ON 4 Exit Program Mode Set Card Reading Type Via the Remote Control Programming Step Remote Control Operation 1 Enter Program Mode Master Code 2 Read EM amp HID card 93 factory default OR 3 Read EM card only 94 OR 4 Read HID card only 95 Add cards by Master Add Card programming Step fadion O 1 Present the Master Add Card Present the user card s to be added Present the Master Add Card to confirm Delete cards by Master Delete Card programming Step ation S 1 Present the Master Delete Card Present the user card s to be deleted Present the Master Delete Card to confirm Reset Procedure Reset Alarm The alarm
7. dditional user cards 1 User ID Present Card The user ID is any number from 0 997 1 Input the 8 10 digit Card number 1 User 1D Card Quantity The first card number Card or fob number MUST be consecutive Add PIN User For Administrator for Remote Control Programming Step Remote Control Operation 1 Enter Program Mode Master Code 2 Add PIN Via remote controller 1 Enter PI N number 4 6 digits Delete User Cards Via the Remote Control Programming Step Remote Control Operation 1 Enter Program Mode Master Code 2 Delete Card By read card OR 3 Delete Card Select Specific I D OR 4 Delete Card by Card Number 2 Present Card Repeat Step 2 for additional user cards before pressing the 2 Enter user I D number The user ID is any number from 1 998 2 Input the 8 10 digits Card number Delete All Users Via the Remote Control Programming Step Remote Control Operation 1 Enter Program Mode Master Code 2 Delete All User Cards 2 Master Code Set Relay Configuration Via the Remote Control The relay configuration sets the behaviour of the output relay on activation 1 Enter Program Mode Master Code 2 Pulse Mode 3 1 99 The relay time is 1 99 seconds 1 is 50mS Default is 5 seconds OR 30 3 Latch Mode Sets the relay to ON OFF Latch mode 4 Exit Program Mode Set Strike out Alarm Via the Remote Control The strike out al
8. e Alternatively you can prevent the alarm from activating by covering the LDR with a non light absorbent substance Black paint or a small amount of Blu Tack will work perfectly fine
9. will sound for 3 minutes To reset present a valid user card or enter Master Code via the remote control Reset to Factory Default To reset to factory default power off press the Exit Button or short circuit the Black GND and Yellow Open wires and then power on there will be two bleeps and the LED light will turn orange keep this condition until you hear a long bleep after 10 seconds The LED will turn red to confirm factory default is successful Reset to Factory Default to add new Mater Cards To reset to factory default power off press the Exit Button or short circuit the Black GND and Yellow Open wires and then power on there will be two bleeps and the LED light will turn orange Release the exit button or the Black GND and Yellow Open wires then present any two 125KHz EM cards or key fobs and the LED will turn red to confirm factory default is successful The first card presented will be the Master Add Card and the second card will be the Master Delete Card Note Reset to factory default the user s card key fob information is still retained The SR2 s alarm trigger is activated by an LDR Light Dependant Resistor which is located to the rear left side of the unit as illustrated below The alarm function is designed as an Anti Theft facility which cannot be disabled but it can be stopped by presenting a valid card or key fob to the reader or entering the Master Code followed by the sign via the remot

Download Pdf Manuals

image

Related Search

Related Contents

HI 96762 Free Chlorine Meter for Drinking Water Application  DeLOCK 65255  VIDEODE RECUL 7" REARVIEW SYSTEM 7"    Mode d`emploi version MODULANTE T4 (230V)  Humminbird PIRANHAMAX10 Fish Finder User Manual  Ligações e conexão com a Internet ilimitadas com a SoftBank!    Samsung SP-L305 User Manual  vista™ auto-darkening casques de la cartouche  

Copyright © All rights reserved.
Failed to retrieve file