Home
PROFESSIONAL HIGH PERFORMANCE TRMS CLAMP
Contents
1. gt 4kHz Bandwidth K 3 5 Crest Factor 600Arms and 900Vrms gt Peak function captures 500us signals gt Min Max for automatic capture of extreme values on 100ms samples gt Temperature measurement up to 1832 F 1000 C via standard K thermocouple gt Continuity at programmable buzzer threshold from 1 to 40Q gt Selectable V Live function buzzer warns of live circuit gt Battery life displays directly in hours at the push of a button gt Automatically detects AC or DC and is auto ranging gt Automatic DC current zeroing gt Backlit digital display gt EN 61010 1 EN 61010 2 032 600V Cat III gt Includes soft carrying case and test leads APPLICATIONS gt Electrical maintenance gt Electrical power distribution gt Safety lighting system maintenance gt Automotive test troubleshooting gt Industrial maintenance gt HVAC gt Phase identification D AEMC INSTRUMENTS SPEC A CATIONS Moves Fo _ Fog _ SOHC SO F09 AC Current Auto Ranging 0 2 to 400Arms 0 2 to 400Arms 0 2 to 400Arms 0 2 to 400Arms 0 2 to 400Arms AC Voltage Auto Ranging 0 2 to 600Vrms 0 2 to 600Vrms 0 2 to 600Vrms 0 2 to 600Vrms 0 2 to 600Vrms DC Current Auto Ranging 0 2 400Arms 0 2to400Arms 0 29 400Arms 0 2 400Arms AC DC Current Auto Rangin fo 400Arms 02to400Ams AC DC Voltage Auto Rangin o Z J o O ooo o oo o o oos os DiodeTest es Yes Yes Cont
2. Diode Test e Diode Test e Power Power 8 lt Min Max e Inrush Current e Inrush Current Factor e Backlighting e Phase Rotation e Temperature e Diode Test e Frequency S e Frequency e Inrush Current e Hold e Physical Quantities e Phase Rotation e Min Max via adaptor e Frequency e Backlighting e Hold e Hold e Min Max e Min Max e Backlighting e Backlighting AEMC D AEM NTS 7 6 193mm Jaw opening trigger _ Hold function Auto zero DC and lead compensation MIN MAX and PEAK functions Liquid crystal display Jaws Opening lt 1 02 26mm Conductor Size one 500MCM cable Anti slip guard Rotary function selector Access key for functions outlined in yellow araound the selector Backlight function F03 F05 amp F07 F05 amp F07 FAA So Fo Recessed safety input terminals All models include test leads a soft carrying case and TRMS Clamp On Meter Model F01 TRMS 400Aac Ohms Continuity TRMS Clamp On Meter Model F03 TRMS 400Aac Dc 600ac Dc Ohms Continuity Temperature TRMS Clamp On Meter Model F05 TRMS Clamp On Meter Model F07 JTS SOURCE For All Your Electrical Test amp Measurement Instruments TRMS Clamp On Meter Model F09 TRMS 400Aac bc 600ac Dc Hz Power kW kVA KVAR Phase Rotation Ohms Continuity TRMS 400Aac bc 600Ac Dc Hz Power kW Phase Rotation Ohms Continuity TRMS 400Aac bdc 600Ac Dc H
3. PROFESSIONAL HIGH PERFORMANCE TRMS CLAMP ON METER Models F01 F03 F05 F07 amp F09 Test As ale 99 Washington Street Depot Melrose MA 02176 Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431 v 2 Visit us at www lestequipmentDepot com gt Hand held size ultra practical and ergonomic gt True RMS measurement through fast sampling accurate on non linear waveforms gt Measure V A Ohms kW Hz Phase Rotation Temperature AC DC model dependent gt Temperature measurement up to 1832 F 1000 C via standard K thermocouple gt Selectable V Live function buzzer warns of live circuit gt Automatic DC current zeroing gt EN 61010 1 EN 61010 2 032 600V Cat Ill HS AEMC INSTRUMENTS CHAUVIN ARNOUX GROUP Preppy e c d P F 4 A i 7 PP w ii a P d F i Model F05 monitoring volts amps and watts on a control panel The F01 FO9 series of clamp on meters is a high performance line of clamp on meters built into a rugged compact sized case with exceptional ergonomic design and extraordinary measurement possibilities These are definitely not your generic off the shelf clamp on They are designed to offer professional measurement possibilities rarely seen in a clamp on meter Integrating a fast microprocessor sampling at a high rate they are completely automatic and perform TRMS measurements on the most distorted waveforms The Models F01 through FO9
4. inuity Beeper Yes Yes Yes Yes Yes w adjustable w adjustable w adjustable threshold threshold threshold Frequency OH Z kW KVA KVAR Power Factor O O J to 00 00 to 1 00 Phase Rotation O J es es Min Max Peak Jo es S e es Yes Hold ws es S s e es e TRE RR TE selectable selectable selectable Auto off es S ss S es es es Yes Yes Adapter AC DC pe to ooo 2 76 X 7 6 x 1 46 2 76 X 7 6 x 1 46 2 76 x 7 6 x 1 46 2 16 X 7 6 x 1 46 2 16 X 7 6 x 1 46 70 x 193 x 37mm 70 x 193 x 37mm 70 x 193 x 37mm 70 x 193 x 37mm 70 x 193 x 37mm Weight 9 17 02 260g 9 17 02 260g 9 17 oz 260g 9 17 oz 260g 9 17 02 260g Backlight pK ves es es e Temperature 50 to 1832 F 50 to 1832 F int or ext 10 to 1000 C 10 to 1000 C Safety Rating EN 61010 1 EN 61010 2 032 600V Cat III Double Insulation D CE Mak Cd Yes 1 2 Indicates voltage higher than instrument rating Remaining time expressed in hours on Models F03 F05 and F07 e TRMS e TRMS e TRMS s TRMS s TRMS e AC DC e AC DC Voltage e AC DC Voltage e AC DC AC DC AC DC AC DC Voltage e AC DC Current e AC DC Current Voltage Voltage e AC Current e Resistance e Resistance e AC DC AC DC e AC DC AC DC e Continuity e Continuity e Continuity Current Current e Hold e Diode Test e Power Power e Resistance e Resistance e Non magnetic e Temperature Factor e Continuity e Continuity sensor e Hold 39
5. offer extraordinary measurement capabilities to the professional engineers and electricians who rely on professional measurement products Here are some interesting facts s All models automatically detect AC or DC in Voltage and Current Just select the function s All models have a V Live function to warn of the use of live circuits or elevated voltages They also auto range for the best resolution on a backlit 4000 count display and have Auto Off to save the battery e Models F07 and F09 measures TRMS Voltage and Current and can incorporate the DC component of the signal for the Truest RMS e Models F07 EOS and FO9 measure in rush currents from one cycle up to 10 cycles and frequency e Models F05 and FO9 measures Phase Rotation using only two leads Power Factor and Power e Model F01 does not have a magnetic core in its jaws e All models are very ergonomic and can be operated with one hand e Other features based on the model include Temperature Min Max Peak AC DC adaptor input enabling the use of accessories large clamps light sensors The Models F01 FO9 are designed for the industrial environment and offer enhanced safety specifications They conform to the demanding international safety standards with a 600V Cat III rating and are CE marked FEATURES gt Hand held size ultra practical and ergonomic design gt True RMS measurement through fast sampling accurate on non linear waveforms
6. z Ohms Continuity Temperature user manual Model F03 measuring temperature on electronic circuit Hz button board using a K thermocouple Cat 2129 51 Cat 2129 52 Cat 2129 53 Cat 2129 54 Cat 2129 50 AEMC INSTRUMENTS