        RF/MF Card Home & Office Lock User Manual V22.0
         Contents
1.    beep   beep  beep       for alarming  The alarming will last for about 20 seconds     9  Malfunction And Solution       Malfunction    Reason    Solution       Touch key card  LED flashes  red light  the buzzer sounds 5       beep       Read card failed     The card is invalid     1  Touch the key card again   2  Create the key card again        Touch key card  LED flashes 2       red light  the buzzer sounds 2 Low voltage  Check and replace the battery      beep     the lock is unlocked   Touch key card  LED flashes The lock is deadbolted  Touch the key card with open    red and blue alternately  no    sound     Deadbolt switch is broken     deadbolt function        Touch key card  LED flashes  blue  the buzzer sounds 1     beep     can not turn down the    handle     The lock is in always open  state    The wires of the mortise do not  connect well with J1 socket     Wire or motor malfunction     1  Touch key card again     2  Connect the wires again              The lock sounds    beep  beep     beep       for alarming        The latch can not be out completely        Close the door well again           KEYU INTELLIGENCE CO   LTD    Email  dobest vip 163 com    
2.  one short  LED blue light is on  then create the mother card successfully  Each lock can  have one mother card at the most  the last one replaces the prior one  After creating a new mother  card  the prior mother card and child card will be terminated at the same time     Operation  Press Reset Button for 3 Seconds   Touch New Mother Card Within 8 Seconds  1 time     Note  If you keep pressing the reset button and do not touch any card for more than 8 seconds  the prior card  information will not be affected     5  Create Child Card  Max 5 groups  each group max 50 cards     5 1  Create key card Group 1  Touch mother card 1 time  the LED flashes in blue  touch the RF MF card which you want to  become Key Card  after a short    beep     the RF MF card is recognized as Key Card by the lock     Operation  Mother Card  1 time    New Key Card  1 time     Note    I  When create key card  the LED is flashing blue  touch the card with one    beep    means create key card  successfully  You can continue to touch other cards before the LED stops flashing  8 seconds after you  touch the last card  the LED stops flashing   Be Suitable for creating other group key card     2  When create key card  the LED is flashing blue  touch the key card have been created again  it will be  terminated   Be Suitable for creating other group key card     3  Df you need the card with open deadbolt function  turn out the deadbolt before you touch and create the  key card   Be Suitable for creating other 
3. RF MF Card Home  amp  Office Lock User Manual V22 0   Suitable For HUNE AYT Series  Mode 2    Thank you for your selection of HUNE AYT Intelligent Card Lock which will bring more  convenience and safety to your life  In order to optimize the performance of your lock  please read  through the User Manual     1  Lock Parameters    Working Voltage  6V DC  4 Pieces Of AA AAA Alkaline Batteries   Working Current   lt 300mA   Static Current   lt 24uA   Lock Weight  2 5  3 5KG  Different model will be different   Working Temperature     10  C  60  C   Alarming Voltage  4 8V    2  Function Card And Mechanical Key    Function card includes mother card and child card  the mechanical key is used for emergency   The mother card is used to create child card and the child card is the key of the lock  Mother card  can not unlock the lock as a key card   For some models  the mother card can unlock the lock      3  Wire Connection Diagram       4 Pieces of AA AAA Alkaline Batteries    Note  The wire connection diagram of some models will be different from here     4  Create Mother Card    Install the batteries  the first card you touch to the induction part of the new lock will be  recognized as the mother card  If you need to create a new mother card  press the reset button  signed    SW    or    S1    on the IC for 3 seconds  after a long    beep    and LED blue light on  touch the  card you want to created as mother card within 8 seconds  the buzzer sounds    beep beep    for one  long and
4. group key card      5 2  Create key card Group 2  Touch mother card 2 times  the LED flashes in blue  touch the RF MF card which you want  to become Key Card  after a short    beep     the RF MF card is recognized as Key Card by the lock     Operation  Mother Card  2 times    New Key Card  1 time     5 3  Create key card Group 3  Touch mother card 3 times  the LED flashes in blue  touch the RF MF card which you want  to become Key Card  after a short    beep     the RF MF card is recognized as Key Card by the lock     Operation  Mother Card  3 times    New Key Card  1 time     5 4  Create key card Group 4  Touch mother card 4 times  the LED flashes in blue  touch the RF MF card which you want  to become Key Card  after a short    beep     the RF MF card is recognized as Key Card by the lock     Operation  Mother Card  4 times    New Key Card  1 time     5 5  Create key card Group 5  Touch mother card 5 times  the LED flashes in blue  touch the RF MF card which you want  to become Key Card  after a short    beep     the RF MF card is recognized as Key Card by the lock     Operation  Mother Card  5 times    New Key Card  1 time     6  Terminate Child Card    6 1  Terminate key card Group 1  Touch mother card   time  the LED flashes in blue  do not touch any card for about 8 seconds   After a long    beep     the key cards in group 1 will be terminated     Operation  Mother Card  1 time     6 2  Terminate key card Group 2  Touch mother card 2 times  the LED flashes in blue  do n
5. ot touch any card for about 8  seconds  After a long    beep     the key cards in group 2 will be terminated     Operation  Mother Card  2 times     6 3  Terminate key card Group 3  Touch mother card 3 times  the LED flashes in blue  do not touch any card for about 8  seconds  After a long    beep     the key cards in group 3 will be terminated     Operation  Mother Card  3 times     6 4  Terminate key card Group 4  Touch mother card 4 times  the LED flashes in blue  do not touch any card for about 8  seconds  After a long    beep     the key cards in group 4 will be terminated     Operation  Mother Card  4 times     6 5  Terminate key card Group 5  Touch mother card 5 times  the LED flashes in blue  do not touch any card for about 8  seconds  After a long    beep     the key cards in group 5 will be terminated     Operation  Mother Card  5 times     6 6  Terminate one key card  Touch mother card 1   5 times  the LED flashes in blue  touch the key card you want to    terminate  After a long    beep     the key card is terminated   Operation  Mother Card  1  S5 times    Key Card you want to terminate  1 time     6 7  Terminate all key cards  Touch mother card 7 times  the LED flashes in blue  do not touch any card for about 8    seconds  After a long    beep     all the key cards of the lock will be terminated   Operation  Mother Card  7 times     Note  If you touch the mother card 8 times continuously  the buzzer will sound    beep  beep  beep     the lock will    exit the se
6. tting card operation     7  Unlock The Lock    7 1  Unlock by key card  Touch the key card  after a    beep     or music  and the LED flashes in blue  turn down the  handle and open the door     Operation  Key Card  1 time    Turn down the handle    Note    I When the deadbolt is out  if you touch the key card without the open deadbolt function  the LED flashes  red and blue alternately  The lock can not be unlocked    2  Myou need to set the lock always open  touch the key card to unlock the lock and do not turn down the  handle  touch the same key card again within 3 seconds  When the lock is in always open state  touch the  key card  the lock locks automatically    3  Touch the key card and do not turn down the handle  after 8 seconds  the lock will lock automatically     7 2  Unlock by mechanical key   In case the power of the lock runs out or the electrical part have faults  you can  use the sucker or magnet to take off the cylinder cap  insert and turn the mechanical  key to unlock     Note  The mechanical key is used to unlock for emergency  please make sure the mechanical key is kept    properly out of the room     8  Low Voltage Alarming And Not Good Locking Alarming    If the batteries    voltage is low  touch the key card  two long    beep    from the buzzer  LED  flash red for two times  then the lock is unlocked  Please change 4 pieces of new batteries as soon    as possible     When closing the door  if the latch can not be out completely  the buzzer will sound 
    