1. The calibration adjusts the internal circuitry to get the best accuracy Use these functions to calibrate the vertical and horizontal systems For maximum accuracy at any time run this calibration if the ambient temperature changes by 5 C or more Before running this procedure do these steps 1 Disconnect any probes or cables from all channel inputs otherwise failure or damage to the oscilloscope may be occurred 2 Push the Utility button and select Calibrate 56 DSO1000 SERIES HANDHELD OSCILLOSOPE The calibration screen is shown as in Figure 2 43 Calibration CH1 Processing Calibration CH2 Not Yet Figure 2 43 The Calibration Screen Note The oscilloscope must have been working or warm up at least 30 minutes before running calibration to get best accuracy The oscilloscope will calibrate parameter of vertical system CH1 CH2 Pass Fail The Pass Fail function monitors changes of signals and output pass or fail signals by comparing the input signal is within the pre defined mask Press Utility gt Pass Fail to go to the following menu The Pass Fail menu Page 1 2 Enable Source Output Operate 12 57 USER S MANUAL 1060 1200 1600 1600H Figure 2 44 The Pass Fail menu The Pass Fail menu Page 2 2 Stop Output Figure 2 45 The Pass Fail menu The Pass Fail menu table Page 1 2 Enable ON Turn on Pass Fail test a OFF Turn off Pass Fail t
2. 71 USER S MANUAL 1060 1200 1600 1600H Figure 2 65 the Lan Setting window Press the button F2 in the IO Set menu RS232 you can modify Baud Rate value See the IO Set menu RS232 in Figure 2 64 When you acquire an analog signal the oscilloscope will convert it into a digital one There are two kinds of acquisition Real time acquisition and Equivalent acquisition The real time acquisition has three modes Sample Peak Detect and Average The acquisition rate is affected by the setting of time base Press UTILITY F4 button to show the menu of Qcquire Peak the oscilloscope gets the maximum and minimum values of the input signal over each sample interval and uses these values to display the waveform Sinx x The Sinx x can be used in time base range of 50ns 5ns 72 DSO1000 SERIES HANDHELD OSCILLOSOPE Chapter 3 Using examples Example 1 Simple Measurement To acquire and display a signal please do the steps as followings 1 Connect signal to CH1 by using probe 2 Press the key AUTO on key panel The Oscilloscopes set the vertical horizontal and triggers controls at the best status automatically Also you can adjust the controls to meet your measurements to optimize the waveform display To measure the frequency and Vpp you can do these steps as followings 1 Press the key MEAS Select Source gt CH1 and select Type gt Voltage then press the key F5 and then press the key F2 to m
3. Figure 3 3 FFT Measurement Cursor Type Y 76 DSO1000 SERIES HANDHELD OSCILLOSOPE See the FFT Measurement Cursor Type X in figure 3 4 Figure 3 4 FFT Measurement Cursor Type X Example 4 The Pass Fail Test The Pass Fail Test is one of the enhanced special functions of the oscilloscope By this function the oscilloscope could compare the input signal with the established waveform mask If the waveform touches the mask a Fail signal occurs Otherwise the test passes When needed a programmable output can be used for external automatic control applications The output is built in as a standard feature and is optically isolated Do the steps as followings 1 Press the key Utility to enter the Utility menu 2 Press the key F5 in the panel to enter the page 2 4 3 Select the Pass Fail in the Utility menu to enter the Pass Fail menu 4 Select Enable to ON to turn on Pass Fail Select Source CH2 the input source select Stop Output to OFF or ON in Page 2 2 of Pass Fail menu 5 Create the Pass Fail Mask Change the Vertical or Horizontal value by click the up or down key in the panel to set the div of the vertical or horizontal values Select Create or Save or Load button if you need 6 Select Operate to Start in Pass Fail menu to start the Pass Fail function 77 USER S MANUAL 1060 1200 1600 1600H See the Pass Fail window in figure 3 5 Figure 3 5 The Pass Fail Window Example
4. In Track Cursor Mode the Cursor A and Cursor B move together with the selected waveform See figure 2 62 69 USER S MANUAL 1060 1200 1600 1600H Figure 2 62 Track Cursor Mode Please do the following steps 1 Select menu Mode gt Track 2 Select Source for measurements Select options as followings Cursor A gt CH1 CH2 Cursor B gt CH1 CH2 3 Select Cursor A or Cursor B Move the Select Cursors to adjust the increments between the Cursors 4 Get the values between Cursor A and Cursor B delt x is the time between Cursor A and Cursor B 1 delt x is the frequency between Cursor A and Cursor B delt y is the voltage between the Cursor A and Cursor B IO Set Press UTILITY F5 F5 F5 F5 F2 button to show the menu of IO Set The IO Set menu LAN 70 DSO1000 SERIES HANDHELD OSCILLOSOPE Ia Set LAN Setting Figure 2 63 The IO Set menu LAN The IO Set menu table LAN The IO Set menu RS232 Ia Set Baud Rate R5732 Figure 2 64 The IO Set menu RS232 The IO Set menu table RS232 Baud Rate Set Baud Rate parameter for RS232 gt j 4 Go to the Utility menu page Press the button F2 in the IO Set menu LAN then a small window pops up You can select the Arrow keys to move the cursor position in which you want to modify parameter then press the Enter key to pop up a soft key board by which you can set what you want See the LAN setting window in Figure 2 65
5. toes Recan recorded waveform rom tral marry caton gt enemmn O i The Record menu when the save as external memory Storage Mode Page 2 2 Create File Create a new file Load Delete File P Delete a selected file Recall recorded waveform from external memory location Language DSO1000 series oscilloscopes have multi language user menu choose as your desire Press Utility Language to select the language Signal Measurement Press the MEAS button to display the menu of the automatic measurements settings The Measure menu Page 1 5 Source Type eas All J v5 Figure 2 54 The Measure menu 63 USER S MANUAL 1060 1200 1600 1600H Ya The Measure menu Page 2 5 Fk to Pk Maximum Minimurn u5 Figure 2 55 The Measure menu The Measure menu Page 3 5 Figure 2 56 The Measure menu The Measure menu Page 4 5 qm A45 Amplitude RMS CRMS Figure 2 57 The Measure menu The Measure menu Page 5 5 Oyreshoot Preshoot Figure 2 58 The Measue menu The oscilloscope provides 22auto measurements Vpp Vmax Vmin Vtop Vmid Vbase Va mp Vavg Vrms Vcrms Overshoot Preshoot Freq Period Rise Time Fall Time Width Width Duty Duty Delay1 gt 2t Delay1 gt 2 12 voltage and 10 time measurements The Measure menu table 64 DSO1000 SERIES HANDHELD OSCILLOSOPE Sse CH1 Select CH1 or CH2 as source CH2 channel for measurement a Select to m
6. The ALT Trigger menu Type Pulse Page 1 2 Mode Channel Type When a ae Figure 2 32 The ALT Tirgger menu The Alternative menu table Trigger Type Pulse Page 1 2 Channel CH1 Set trigger mode for CH1 CH2 Set trigger mode for CH2 ee Set Edge Pulse Trigger as the trigger type USER S MANUAL 1060 1200 1600 1600H Pulse width more than selecting pulse condition Pulse width less than selecting pulse condition Pulse width equal to selecting pulse condition Pulse width more than selecting pulse condition Pulse width less than selecting pluse condition Pulse width equal to selecting pulse condition a So og Figure 2 33 The ALT Trigger menu The Alternative menu table Trigger Type Pulse Page 2 2 2 2 Poe od Back to the previous menu page Setting Set the width of the pulse HF Reject pea Reject high frequency signals or not 50 Set the trigger level to the center of the signal Video Trigger Setting The Video trigger mode is designed to captrue the video signal type to display stable NTSC or PAL SECAM standard composite video waveforms Press TRIG F1 Video button to show the Video trigger menu as the following table The Video Trigger menu Page 1 2 46 DSO1000 SERIES ee eee espero oem 00 eee HANDHELD OSCILLOSOPE Mode Channel Polarity Syng KE U The Video Trigger menu Page 2 2 Standard Cn CER Figure 2 34 The Video Tirgger menu The
7. and ensuing damage Appendix C Maintenance General Care Do not store or leave the instrument in where the LCD display will be exposed to direct sunlight for long periods of time Caution To avoid damage to the instrument or probes do not expose them to sprays liquids or solvents Cleaning If this instrument requires cleaning disconnect it from all power sources and clean it with a mild detergent and water Make sure the instrument is completely dry before recon necting it to a power source To clean the exterior surface perform the following steps 1 Remove loose dust on the outside of the instrument and probes with a lint free cloth Take care to avoid scratching the clear plastic display filter 2 Use a soft cloth dampened with water to clean the instrument Notice To avoid damage to the surface of the instrument or probes do not use any abrasive or chemical cleaning agents Storage of oscilloscope If the test tool is to be stored for a long time it is required to charge the lithium battery 100 DSO1000 SERIES HANDHELD OSCILLOSOPE before storage Charging the oscilloscope The lithium battery is possibly not charged when delivery To make the battery with enough electric quantity it must be charged for 4 hours the test tool must be turned off during charging The battery can supply power for 6 hours after being charged com pletely To avoid superheat of battery during charging the environment
8. and training involving applications of analog circuit tests and troubleshooting Product features Dual Channel Bandwidth 60MHz DSO1060 200MHz DSO1200 600MHz DSO1600 600MHz DSO1600H DSO1000 SERIES HANDHELD OSCILLOSOPE Maximum real time sampling rate 250MSa s DSO1060 500MSa s DSO1200 1GSa s DSO1600 2GSa s DSO1600H m Memory depth 32K points Single Channel 16K points Dual Channels m Color TFT LCD 320x240 pixels resolution USB storage and printing supports firmware upgrade via USB interface Adjustable waveform intensity more effective waveform viewing One touch automatic setup ease of use AUTOSET m 15 Waveforms 15 setups supports CSV and bitmap format m 22 Automatic measurements Automatic cursor tracking measurements m Waveform recorder record and replay dynamic waveforms m User selectable fast offset calibration a Built in FFT function Frequency Counter Pass Fail Function Addition Subtraction Multiplication and Division Mathematic Functions Advanced trigger types include Edge Pulse width ALT Video Multiple Language User Interface Pop up menu makes it easy to read and easy to use Built in multi language help system m Easy to use file system supports Multi Language characters file name input m Selectable bandwidth limit DSO1060 20MHz DSO1200 20MHz 100MHz DSO1600 20MHz 100MHz 200MHz 350MHz DSO1600H 20MHz 100MHz 200MHz 350MHz USER S MANUAL 10
9. following 1 Press the CH1 or CH2 button and then the function menu appears at the bottom of the screen 2 Select and press key from F1 to F5 keys to make different settings Now you can find the menu that looks like the following figure 2 1 The CH1 menu Page 1 2 Enable Coupling Probe YoltiDiy Invert Bw Lirit Enable Coupling Probe The CH1 menu Page 2 3 not include DSO1060 D YoltiDiv Invert Bu 20M Ala The CH1 menu Page 3 3 not include DSO1060 20 DSO1000 SERIES HANDHELD OSCILLOSOPE Figure 2 1 The CH1 Menu The following table describes the channel menu Enabl ON Turn on Channel nane OFF Turn off Channel The dc component in the input signal is blocked Coupling The ac and dc components of the input signal are allowed Disconnect the input signal Select one according to the probe attenuation factor to ensure correct vertical scale reading Rest Set the vertical display position back to middle window Go to the next menu page 2 2 Back to the previous menu page lt 1 p pag Coarse Set Voltage range coarsely NEON Set Voltage range finely saver ON Turn on the invert function nye OFF Turn off the invert function BW 20M ON Turn on the BW 20M not include DSO1060 OFF Turn off the BW 20M 2 2 s Back to the previous menu page 3 3 f 5 gt Go to the next menu not include DS01060 Turn on the BW 100M not include DSO1060 Eu oy Turn off the BW 100M 3 3
10. on the cursor measurement Cursor Mode Manual Track Auto 2 Select channel Source for measurements by pressing soft button as Cursor Source CH1 CH2 MATH 3 Select the cursors type by pressing soft button as Cursor Type X or Y 4 Press F4 or F5 to select the Cursor A or Cursor B 5 Move the cursors to adjust the increment between the cursors The values will be automatically displayed on the right upper corner of screen when the cursor function menu is hidden or displaying other menus Comments of Cursor Measurements 1 Auto Cursor Mode The Auto Cursor Mode displays the cursors for the current measuring automatically See figure 2 60 67 USER S MANUAL 1060 1200 1600 1600H Figure 2 60 The Automatic Cursor Mode 2 Manual Cursor Mode In this mode the oscilloscope measures the Y or X coordinate increments between the two cursors See figure 2 61 1 Select menu Mode gt Manual 2 Select menu Type gt X Y to get the vertical or horizontal of Cursor A or Cursor B 3 Select menu Source gt CH1 CH2 MATH to Get the Cursor Source 4 Select Cursor A or Cursor B to adjust the increments between Cursor A and Cursor B 5 Get the values between Cursor A and Cursor B delt x is the time between Cursor A and Cursor B 1 delt x is the frequency between Cursor A and Cursor B 68 DSO1000 SERIES HANDHELD OSCILLOSOPE Figure 2 61 The Manual Cursor Mode 3 Track Cursor Mode
11. output characteristics of the circuit 6 Adjust the scale and offset of the horizontal and vertical to a desirable waveform display The following picture shows a typical example 7 Apply the Ellipse Method to observe the phase difference between the two channels 74 DSO1000 SERIES HANDHELD OSCILLOSOPE See Signal in X Y Format in figure 3 2 AUTO E B Prrirririie i Figure 3 2 Signal in X Y Format Instruction of the Ellipse Method Single must be centersd in X 75 USER S MANUAL 1060 1200 1600 1600H Sin A B or C D where 9 phase shift in degrees between the two signals From the formula above 6 tarcsine A B or tarcsine C D O must be in the range of O t1 2 or 311 2 2Tr if the main axis of the ellipse is between and III quadrant If the main axis is at Il and IV quadrant must be in the range of 11 2 Tr or 11 3T1 2 Example 3 The FFT Cursor Measurements FFT measurement includes Amplitude measurement Vrms or dBVrms and the Frequency measurement Hz Do these steps as followings 1 Press the key CURSOR to show Cursor menu 2 Select Mode gt Manual to enter the Manual Cursor Mode window 3 Select Type gt X Y select the Cursor Type to X or Y 3 Select Source gt MATH FFT operation in the Manual Cursor Mode window 4 Drag the Cursor to the point of interest See the FFT Measurement Cursor Type Y in figure 3 3 oT l l l dJ
12. power via a power adapter The oscilloscope can still work with built in Li ion battery even without AC power supply Turn the oscilloscope on by pressing down the power on off key The instrument then performs Self checking after power on The welcome picture will display on the screen when the system finishes Self checking The oscilloscope is powered up in its last setup configuration Hantek HAND HELD SCOPEMETER DSO1000 SERIES www hantek com cn Figure 1 6 The Login window Menu Operation The following example shows how to use the tools menus to select a function as shown in the following figure DSO1000 SERIES HANDHELD OSCILLOSOPE CH1 eS Enable Coupling Figure 1 7 The Menu 1 Press the MENU ON OFF key to display the Function Menu on the bottom of the screen and the corresponding optional settings on the bottom Press MENU ON OFF again to hide the Function Menu 2 Choose one key from F1 to F5 and press it to change function setting Set up the vertical system 1 Change the vertical setup and notice that each change affects the status bar differently m Change the vertical sensitivity with No or 4 button and notice the change in the status bar 2 Move the signal vertically m The V button moves the signal vertically Also notice that the channel symbol on the left side of the display moves in conjunction with the button To set up the horizontal system 1 Change the time bas
13. rising edge Do these steps as followings 1 Set the probe and the channel attenuations to 10X 2 Press the key TRIG to show the Trigger menu 3 Select Mode gt Edge Set Source to CH1 and Slope to Rising Set Sweep to Single 4 Adjust the Volts Div and the time base in a proper range for the signal 5 Drag the trigger level sign on the waveform display screen 6 When the trigger conditions are met data appears on the display representing the data points that the oscilloscope obtained with one acquisition 80 DSO1000 SERIES HANDHELD OSCILLOSOPE CHAPTER 4 Multimeter About this chapter This chapter provides an introduction to the multimeter functions of DSO1000 Series The introduction gives guides to show how to use the menus and perform basic measurements Connecting the Meter Use the 4 mm safety banana jack inputs for the Meter functions 10A mA COM V QO C Multimeter Operation Window a 5 E r Figure 4 1 Multimeter operation window Description 1 Battery electric quantity indictor 2 Measurement mode indictors 81 USER S MANUAL 1060 1200 1600 1600H DC Direct electric measurement AC Alternating electric measurement 3 The symbol of Mutimeter current mode 4 Manual Auto range indictors among which the MANUAL refers to measuring range in manual operation mode and Auto means the measuring range in automatic operation mode 5 The reading value of measurement 6 The bar
14. settings and can be recalled at any time Memory location Specify the memory location to save recall the waveforms and setups Load Recall saved waveforms setups and default settings Save Save waveforms and setups Note 1 Select save stores not only the waveforms but also the current oscilloscope 2 The oscilloscope can store 15 settings permanently and can restore at any time Utility Function 52 N DS01000 SERIES HANDHELD OSCILLOSOPE N Press the Utility button to show the menu of the settings in the Utility system The series without RS232 and LAN The Utility menu Page 1 4 Utility Fic Eiht Dan E re a aa The Utility menu Page 2 4 Ll t i i t pi Language Recard Mid The Utility menu Page 3 4 tility Shutdown Sound ee Calibrate 3 4 b The Utility menu Page 4 4 Utility Configure qa Ard Update Systeminfo 4ra n Figure 2 41 The Utility menu without RS232 and LAN The series with RS232 and LAN The Utility menu Page 1 5 Litility ic DM Display Acquire 4 5 m The Utility menu Page 2 5 r USER S MANUAL 1060 1200 1600 1600H Record The Utility menu Page 3 5 Shutdown Sound 7 m y5 Calibrate The Utility menu Page 4 5 Configure 1 E 45 Update em Info The Utility menu Page 5 5 Figure 2 42 The Utility menu with RS232 and LAN The Utility menu table Page 1 4 and Pa
15. the oscilloscope To do this m Align the slot in the probe connector with the key on the CH1 BNC connector m Push to connect and twist to the right to lock the probe in place m Attach the probe tip and ground lead to the PROBE COMP connector Set the probe attenuation of the oscilloscope to 10X To do this push CH1 Probe 10X Ace Figure 1 5 Set the probe 3 Push the AUTO button Within a few seconds a square wave will display approximately 1 kHz 2 V peak to peak Turn off CH1 and turn on CH2 repeat steps 2 and 3 13 USER S MANUAL 1060 1200 1600 1600H To compensate probes Perform this adjustment to match the characteristics of the probe and the channel input This should be performed whenever attaching a probe to any input channel the first time 1 From CH1 menu set the probe attenuation to 10X press CH1 Probe 10X Set the switch to X10 on the probe and connect it to CH1 of the oscilloscope When using the probe hook tip insert the tip onto the probe firmly to ensure proper connection Attach the probe tip to the probe compensator connector and the reference lead to the ground pin Select CH1 and then press AUTO 2 Check the shape of the displayed waveform Correctly Compensated Over compensated DSO1000 SERIES HANDHELD OSCILLOSOPE Under Compensated 3 If necessary use a non metallic tool to adjust the trimmer capacitor of the probe for the flattest square wave being d
16. 0H Connect and Disconnect Properly Do not connect or disconnect probes or test leads while they are connected to a voltage source m Connect and Disconnect Properly Connect the probe output to the measurement device before connecting the probe to the circuit under test Disconnect the probe input and the probe reference lead from the circuit under test before disconnecting the probe from the measurement device m Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings information before making connections to the product m Use Proper Probe To avoid shock hazard use a properly rated probe for your measurement a Avoid Circuit or Wire Exposure Do not touch exposed connections and components when power is on Do Not Operate With Suspected Failures If suspected damage occurs with the device have it inspected by qualified service personnel before further operations m Provide Proper Ventilation Refer to the installation instructions for proper ventilation of the device Do not operate in Wet Damp Conditions Do not operate in an Explosive Atmosphere m Keep Product Surfaces Clean and Dry Digital Oscilloscopes DSO1000 Series digital Oscilloscopes offer exceptional waveform viewing and measurements in a compact lightweight package DSO1000 series is ideal for production test field service research design education
17. 2 2 Delete Fie Load Figure 2 18 The External menu The External menu table Delete File F To delete the chosen file USER S MANUAL 1060 1200 1600 1600H Display a Reference Waveform Figure 2 19 Reference display 1 Press M R button to show the reference waveform menu 2 Press F2 to select the reference channel CH1 CH2 or MATH 3 Press F4 to save REF 4 Press F5 to load an internal REF file 5 Press F1 button to turn on REF Note The Reference function is not available in X Y mode Set Horizontal System The horizontal system changes the horizontal scale and position of waveforms The horizontal center of the screen is the time reference for waveforms Changing the horizontal scale causes the waveform to expand or contract with respect to the screen 36 DSO1000 SERIES OOC m_ see 0E_EE S HANDHELD OSCILLOSOPE center Horizontal position changes the displayed waveform position relative to the trigger point Press HORI button to show the horizontal system menu The settings of this menu are listed in the following table The Horizontal Menu Time Base ALT Mag Holdott ne Figure 2 20 The Horizontal menu The Horizontal Menu Table Show the relative relation between vertical voltage and horizontal time Time base Show CH1 value at X axis CH2 value at Y axis In Roll Mode the waveform display updates from right to left Pressing this button clears trigger offse
18. 5 Reduce the noise on a signal See the signal with random noise in figure 3 6 To reduce random noise do the following steps 1 Set the Probe and the channel attenuations to x10 2 Connect the signal to the oscilloscope to display a stable wave 3 Reduce the noise Select the Acquire Mode in Acquire menu If there is noise within the signal and the waveform looks too wide in this case choose average acquisition In this mode the waveform will be thin and easy to observe and measure Use the Average following the steps 1 Select Acquire in the Utility menu to enter the Acquire menu 2 Select Mode to Average then Press F2 to change the Averages form 2 to 128 to switch the number of averages that best eliminates the noise from the displayed waveform 3 Select Mode to Normal to cancel this function 78 DSO1000 SERIES HANDHELD OSCILLOSOPE See signal after reducing random noise in figure 3 7 CHI w 16 6 mil Mode sampling xia Figure 3 6 Signal with random noise 79 USER S MANUAL 1060 1200 1600 1600H EN 0am T Mode A s Sampling Average A 64 Real Time DO Figure 3 7 Signal afer reducing random noise Example 6 Capture a Single signal To capture a single event it needs to gather some pre test knowledge of the signal in order to set up the trigger level and slope correctly For example if the event is derived from TTL logic a trigger level of 2 Volts should work on a
19. 60 1200 1600 1600H CHAPTER 1 Getting Start This chapter covers the following topics m General Check m Functional Check m The User Interface m Input Connections m To compensate probes m To display a signal automatically m Using the Oscilloscope DSO1000 SERIES HANDHELD OSCILLOSOPE General Check When you have got a new DSO1000 series oscilloscope it is suggested that you should perform a general inspection on the instrument according to the following steps m Check the shipping container for damage Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has been checked mechanically and electrically m Check the accessories Accessories supplied with the instrument are listed in Accessories in this guide If the contents are incomplete or damaged please notify our distributor at your local area or the overseas sales dept m Check the instrument In case there is any mechanical damage or defect or the instrument does not operate properly or fails performance tests please notify our distributor at your local area or the overseas sales dept User s Interface The first thing to do with a new oscilloscope is to know its front panel This chapter helps to be familiar with the layout of the keys and how to use them Read this chapter carefully before further operations Front Panel Figure 1 1 The buttons no
20. Backlight Display Display Resolution 240 Vertical X 320 Horizontal pixels Interface Optional RS232 LAN Power Source AC 100V 240V 50Hz 60HZz Line Voltage Range DC Input 12VDC 1500mA Battery Power Installed 6 hours Li ion Battery Mechanics 245 x 163 x 52 mm Weight 1 2 Kg Other GND Reference oscilloscope and Multimeter Independence Caution Technical specifications may be jubject to variations without notice USER S MANUAL 1060 1200 1600 1600H Chapter 7 Appendix Appendix A Accessories 1 Probex2 1 2m 1 1 10 1 Passive Probes 2 A Power Adapter that fits the standard of destination country 3 A User s Guide 4 A User Registration Form 5 A User Warranty Card 6 A Software CD Appendix B Warranty We warrant our products mainframe and accessories in materials within the warranty period During the period concerned We guarantee the free replacement or repair of products which are approved defective To get repair service or obtain a copy of the whole warranty statement please contact with your nearest sales and service office We do not provide any other warranty items except the one being provided by this sum mary and the warranty statement The warranty items include but not being subjected to the hinted guarantee items related to tradable characteristic and any particular purpose We will not take any responsibility in cases regarding to indirect particular
21. F Go to the first menu not include DSO1060 21 USER S MANUAL 1060 1200 1600 1600H ee Turn on the BW Limit BY Dinu a Turn off the BW Limit 1 Change Volt DIV It is the default setting of Volts Div in a 1 2 5 step sequence from 1mV div 2mV div 5mV div or 10mV div 20mV div 50mV div to 1V div 2 V div 5 V div The Volt DIV will be displayed in the status bar on the bottom of the screen Figure 2 2 Channel Volt Div Press CH1 gt Volt Div Coarse Fine to Set Volt Div range 2 Set Channel Coupling With CH1 taken for example input a sine wave signal containing a dc offset Press CH1 Coupling AC to set AC coupling It will pass AC component but block the DC component of the input signal The waveform is displayed as Figure 2 3 DSO1000 SERIES HANDHELD OSCILLOSOPE Time 560 042 Enable Coupling Probe Figure 2 3 Waveform Display Press CH1 gt Coupling DC to set DC coupling It will pass both AC and DC components of the input signal The waveform is displayed as Figure 2 4 23 USER S MANUAL 1060 1200 1600 1600H CH eee Time 504 045 Enable Coupling Probe Bacal He b Figure 2 4 Waveform Display Press CH1 Coupling GND to set GND coupling it disconnects the input signal The screen displays as Figure 2 5 24 DSO1000 SERIES HANDHELD OSCILLOSOPE CHi Eamets oT Time 5 Enable Coupling Probe Figure 2 5 Waveform Display 3 Se
22. Hantek Hantek Electronic co Ltd No 177 zhuzhou road huite industry city QingDao China CE DSO1000SERIES HANDHELD OSCILLOSCOPE USER S MANUAL 1060 1200 1600 1600H www hantek com cn DSO1000 SERIES HANDHELD OSCILLOSOPE USER S MANUAL 1060 1200 1600 1600H USER S MANUAL 1060 1200 1600 1600H Content General Safety Notice l 3 Digital OSCIIOSCOPES 0 cece ee eee eeeeee siisii ea 4 CHAPTER 1 Getting Start 6 General Check cceceeeee eee eee eee eee eee ee ee ee eeae 7 User s Intetace ciccccectcacopenctaeseanda niani ani 7 Input Connections 12 Function Check 0 cc cseneeseeee sees ene edene neces 13 To compensate probeS 0 eceeeeeeee reese een 14 To display a signal automatically eee 15 Using the Oscilloscope 16 CHAPTER 2 Operating Oscilloscope 19 Set Vertical SySteM 0 eee eect eee ee eeea eens 20 Set Horizontal System 36 Set Trigger SysStEM ceeeeeeeeeeeeeeeeeeneen unien 40 Save Recall Waveforms and Setups 48 Utility FUNCHION 0 cette eee e eee need 52 Signal Measurement 63 Cursor Measurement l enn eerren 66 lO Seta Hee ete ee eed 70 CHAPTER 3 Using examples 73 CHAPTER 4 Multimeter 81 CHAPTER 5 Troubleshooting eceeeeeeenee eae eeaes 95 CHAPTER 6 Specifications 96 CHAPTER 7 Appendix 100 DSO1000 SERIES HANDHELD OSCILLOSOPE General Safe
23. O1000 SERIES HANDHELD OSCILLOSOPE Source ICHI CH2 CH2 Edge Pulse Width Alternative Video X Y Mode Phrase Shift Max 3 degree Cursors and Measurement Vpp Vamp Vmax Vmin Vtop Vmid VbaseVpp Vamp Vmax Vmin Vtop Vmi Voltage d Vbase Vavg Vrms Vcrms Preshoot Overshoot time Frequency Period Rise time Fall Time Positive Width Negative Width Duty Cycle Delay 1 gt 2t Delay 1 2 Manual Track Auto Measure Modes Addition Subtraction Multiplication Division FFT 15 Waveforms and setups Meter Mode Maximum Resolution 6000 Counts DMM Testing Modes Voltage Current Resistance Capacitance Diode amp Continuity Time Maximum Input Voltage AC 600V DC 800V Maximum Input Current AC 10A DC 10A Input Impedance 10MQ Meter Specification 97 USER S MANUAL 1060 1200 1600 1600H 600 0mV 100uV 600 0V 100mV 60 00mV manual 10uV 600 0mV manual AC Voltage 6 000V 1 3digit 60 00mA 1 5 1digit ae DC Curent 000 0mA 1 1digit 100uA 1 5 3digit 60 00mA 1 5 3digit 600 0mA 1 1digit 100A AC Current 1 5 3digit 600 0 1 3digit 0 10 60 00K Resistance 1 1digit 600 0K 1000 60 00M 1 5 3digit 10KQ 4 000uF 1 1digit Capacitance 40 00uF Attention The smallest capacitance value that can be measured is 5nF 98 DSO1000 SERIES HANDHELD OSCILLOSOPE Range Resolution lt 100 On off Test Display TFT LCD Type 5 7 Inch width LED
24. Video Trigger menu table Channel CH1 Set trigger mode for CH1 anne CH2 Set trigger mode for CH2 Applicable to the video signal of which the black level is Normal low Polarity Applicable to the video signal of which the black level is Invert high All Field Set trigger on the falling edge of the first serration pulse to field Odd Field Set trigger on the falling edge of the first serration pulse Sync to odd field Even Field Set trigger on the falling edge of the first serration pulse to even field Line Num Set trigger on the selected line in even field or odd field All Lines Set trigger on the first line found 1 2 Go to the next menu page O oe Back to th i lt ack to the previous menu page Set the lines of trigger video PAL SEC Set video standard to PAL SEC Standard NTSC Set video standard to NTSC USER S MANUAL 1060 1200 1600 1600H Force the oscilloscope to trigger in the absence condi ton Let oscilloscope to trigger in the suitable trigger condi ton Auto Normal Let osclloscope to trigger one time in the suitable trig ger condition then stop 2 2 ls ko Back to the previous menu page Term interpretation Single Auto This sweep mode allows the oscilloscope to acquire waveforms even when it does not detect a trigger condition If no trigger condition occurs while the oscilloscope is waiting for a specific period as determined by the time base setting it will force itse
25. ack to the previous menu page Addition Subtraction Multiplication Division and FFT In the Math function use the addition subtraction multiplication division and FFT to operate and analyze the waveform The multiplication function window is displayed in figure 2 13 30 DSO1000 SERIES HANDHELD OSCILLOSOPE Prrriririnid Figure 2 13 The multiplication 7 FFT The FFT Fast Fourier Transform process converts a time domain signal into its frequency components mathematically FFT waveforms are useful in the following applications m Measure harmonic content and distortion in systems m Characterize noise in DC power supplies m Analyze harmonics in power lines The FFT menu Page 1 2 FFT Enable Operate Source Wir v2 The FFT menu Page 2 2 31 USER S MANUAL 1060 1200 1600 1600H Figure 2 14 The FFT menu The FFT menu table Enable ON Turn on FFT OFF Turn off FFT os Define CH1 or CH2 as FFT source Rectangle Window Hanning Select window for FFT Hamming Blackman 1 2 Go to the next menu page a Back to the previous menu page Scale Vrms Set Vrms as vertical unit dBVrms Set dBVrms as vertical unit Displa Full Display waveform in full screen p ay Split Display waveform in split screen 2 2 Back to the previous menu page Note 1 Signals that have a DC component or offset can cause incorrect FFT waveform component magnitude values To minimize the DC comp
26. ake a Pk to Pk test The Vpp value will display on the bottom of the waveform interface 2 Press the key MEAS select Source gt CH1and select type gt Time then Press the key F5 and then press the key F2 to make a Frequency test The Frequency value will display on the bottom of the waveform interface 3 Click the item Clear in the Measure menu To clear the measurements on the waveform interface See the measurements in the figure 3 1 73 USER S MANUAL 1060 1200 1600 1600H Figure 3 1 The Vpp and Freq measurement Window Example 2 The Application of the X Y Operation X Y Plot acts to analyze correlation of data of two channels Lissajous diagram is displayed in the screen when you use X Y Plot which enables to compare frequencies amplitudes and phases of counterpart waveform against the reference waveform This makes it possible to compare and analyze frequency amplitude and phase between the input and output Do these steps as followings 1 Set the probe attenuation to x10 Set the switch to x10 on the probes 2 Connect the CH1 probe to the input of the circuit and connect the CH2 probe to the output of the circuit 3 Click the key AUTO on the panel 4 Adjust the vertical scale and offset to display approximately the same amplitude signals on each channel 5 Select Time Base gt X Y format in Horizontal menu The oscilloscope will display a Lissajous pattern representing the input and the
27. ana jack input 4 Connect the red and black leads to the measured points and the AC current value of measured points will be displayed on the screen Then the screen will look like the following figure 4 10 90 DSO1000 SERIES HANDHELD OSCILLOSOPE AC TiS Figure 4 10 AC Current Measurement for 600 mA To measure an AC current which is larger than 600 mA do the following 1 Press the A key and then DC appears on the screen The unit on the main reading screen is mA 2 Press F2 key to switch to10A measurement the unit on the main reading screen is A 3 Press the F1 key once and AC will display on the bottom of the screen 4 Insert the black lead into the COM banana jack input and the red lead into the 10A banana jack input 5 Connect the red and black leads to the measured points and the AC current value of the measured points will be displayed on the screen 6 Press F2 to return to 600 mA measurement Then the screen will look like the following figure 4 11 91 MANUAL 1060 1200 1600 1600H OL A Figure 4 11 AC Current Measurement for 10A Taking a Relative Measurement A currently measured result relative to the defined reference value is displayed in a rela tive measurement The following example shows how to take a relative measurement At first it is required to acquire a reference value 1 Press the Q key 2 Insert the black lead into the COM banana jack input and t
28. e USER S MANUAL 1060 1200 1600 1600H m The c or A button changes the time base in a 1 2 5 step sequence and displays thevalue in the status bar 2 Move signal horizontally m The lt J or gt button moves displayed signal horizontally on waveform window It sets the trigger point position Set up the trigger system 1 Change the trigger Level m The Aor V button changes the trigger level The trigger level value is displayed at the top right of the screen and a line is displayed showing the location of the trigger level 2 Change the trigger setup and notice these changes in the status bar m Press TRIG button in the key panel Choose one key from F1 to F5 and press it to change function setting DSO1000 SERIES HANDHELD OSCILLOSOPE CHAPTER 2 Operating Scope The end user should know how to determine the system setup from the status bar of a Oscilloscope This chapter will detail the oscilloscope function of the test tool m Set Vertical System m Set Horizontal System m Set Trigger System m Save and Recall waveforms and setups m Utility Function m Measure Signal m Cursor Measure USER S MANUAL 1060 1200 1600 1600H a Set Vertical System Each channel of Oscilloscope has its own independent operation menu and it will pop up after pressing CH1 or CH2 button The settings of all items in the menu are shown in the table below To make vertical CH1 and CH2 settings do the
29. e from internal memory Ca Back to the previous menu page The Mask setting menu Page 2 2 When the save as external memory 59 USER S MANUAL 1060 1200 1600 1600H Save Go to save menu same as REF save menu Load Recall mask setting file from external memory Waveform Recorder Waveform recorder records input waveforms from CH1 and CH2 with a maximum record length of 1000 frames Press Utility Record Setting to go to the following Waveform recorder Record the waveforms with specified interval The Recorder menu Record Mode Page 1 2 Mode Source EndFrame Operate m 26 V2 Figure 2 48 The Recorder menu Record Mode The Recorder menu Record Mode Page 2 2 Figure 2 49 The Recorder menu Record Mode The Record menu table Record Mode Page 1 2 Select record mode Select play mode Select storage mode Turn off all recorder function ae Select record source channel lt 1 1000 gt Set number of record frames Start Record stopped press to start recording Operate A Stop Press to stop recording 60 DSO1000 SERIES HANDHELD OSCILLOSOPE OT a 1 2 The Record menu table Record Mode Page 2 2 2 2 leony Back to the previous menu page lt 10 0ms 20s gt Set time interval between record frames Play Play back the recorded waveforms The Record menu Play Mode Page 1 2 wode Operate Play Figure 2 50 The Record men
30. e right of the trigger point 40 DSO1000 SERIES HANDHELD OSCILLOSOPE Trigger Modes The oscilloscope provides four trigger modes Edge Pulse Alternative and Video Edge An edge trigger occurs when the trigger input passes through a specified voltage level in the specified slope direction Pulse Use this trigger type to catch pulses with certain pulse width Alternative Trigger on non synchronized signals Video Trigger on video synchronized signals Edge Trigger Setting An edge trigger determines whether the oscilloscope finds the trigger point on the rising or the falling edge of a signal Select Edge trigger mode to trigger on rising edge falling edge Press TRIG F1 Edge button to show the edge trigger menu as the following table The Edge trigger menu Page 1 2 Mode Source alo pe 7 CHI te The Edge trigger menu Page 2 2 Figure 2 26 The Edge trigger menu The Edge Trigger Table a Define CH1 or CH2 as trigger signal Rising isi Falling Trigger on rising edge or falling edge Acquire waveform even no trigger occurred Acquire waveform when trigger occurred When trigger occurs acquire one waveform then stop HF Reject ON OFF Reject high frequency signals 41 USER S MANUAL 1060 1200 1600 1600H 5 Set the trigger level to the center of the signal Pulse Trigger Setting Pulse trigger occurs according to the width of pulse The abnormal sig
31. easure voltage parameter Meas All ON Turn on all measurement result OFF Turn off all measurement result Clear Clear measurement result on screen Clear measurement result on screen measurement result on screen 1 2 7 Go to the next menu page The Voltage Measurement menu table Menu Description Pk to Pk Peak to peak Max Min Measured over the entire waveform F Voltage of the absolute maximum level Maximum Measured over the entire waveform e Voltage of the absolute minimum level Minimum Measured over the entire waveform Voltage of the statistical maximum level Top Measured over the entire waveform Voltage of the statistical minimum level Base Measured over the entire waveform Amp Base Top Amplitud Measured over the entire waveform The Root Mean Square voltage over the entire waveform Positive Overshoot Max Top Amp x 100 Measured over the entire waveform Preshoot Negative Overshoot Base Min Amp x 100 Measured over the entire waveform Middle Voltage of the 50 level from base to top Average voltage of a waveform CRMS The Root Mean Square voltage over the first cycle in the waveform The Time Measurement menu table 65 Overshoot USER S MANUAL 1060 1200 1600 1600H Rising The time taken fom ower threshold to upper treshod Positive Duty Cycle Positive Pulse Width Period x 100 Duty f Measured of the first cycle in waveform Negative Duty Cycle N
32. egative Pulse Width Period x 100 Duty Measured of the first cycle in waveform Delay1 gt 2f The delay of rising time between CH1 and CH2 Delay1 gt 2 The delay of falling time between CH1 and CH2 Note The results of the automatic measurements will be displayed on the bottom of the screen Maximum 3 results could be displayed at the same time When there is no room the next new measurement result will make the previous results moving left out of screen Cursor Measurement The screen displays two parallel cursors Move the cursors to make custom voltage or time measurements of the signal The values are displayed on the boxes below the menu Before using cursors make sure to set the Signal Source as the channel for measuring Press CURSOR to show the cursor menu as the following The Cursor menu Mode Type Source Cursor B Figure 2 59 The Cursor menu The Cursors menu table 66 DSO1000 SERIES HANDHELD OSCILLOSOPE Manual Set to Manual Mode Mode Track Set to Track Mode Auto Set to Auto Mode OFF Turn off the cursor measure x Shown as vertical line to measure the horizontal Type parameters y Shown as horizontal line to measure the vertical parameters CH1 Source CH2 Select the measurement signal source MATH The oscilloscope measures the Y or X coordinate values of the cursors and the increments between the two cursors To do cursor measurements please do as the following steps 1 Turn
33. er modes for the two vertical channels The options are as follows Edge Pulse The info of the trigger level of the two channels will be displayed on the upper right of the screen See the ALT screen in figure 2 29 Press TRIG F1 ALT button to show the ALT trigger menu as the following table The ALT Trigger menu Type Edge Page 1 2 Mlode Channel Type Slope ne te Figure 2 30 The ALT trigger menu The ALT menu table Type Edge Page 2 2 CH1 Set trigger for CH1 43 USER S MANUAL 1060 1200 1600 1600H ee Set Edge Pulse Trigger as the trigger type Sings Rising Trigger on rising edge P Falling Trigger on falling edge ie a Go to the next menu page AUTO Figure 2 29 ALT Mode Screen Description 1 The trigger type of CH1 2 The horizontal trigger position of CH1 3 The trigger level value of CH1 4 The trigger type of CH2 5 The trigger level value of CH2 6 The time base of CH1 7 The trigger level of CH1 8 The trigger delay time of CH1 9 The horizontal trigger position of CH2 10 The time base of CH2 44 DSO1000 SERIES HANDHELD OSCILLOSOPE 11 The trigger level of CH2 12 The trigger delay time of CH2 13 The CH1 Voltage Div 14 The CH2 Voltage Div 50 Figure 2 31 The ALT Trigger menu The Alternative menu table Type edge Page 2 2 2 2 i i ON i HF Reject OFF Reject high frequency signals or not 50 Set the trigger level to the center of the signal
34. est Sour CH1 Select Pass Fail test on CH1 ource CH2 Select Pass Fail test on CH2 Fail Output when Fail condition detected Output Pass Output when Pass condition detected P Fail Beep Output and Beep when Fail condition detected Pass Beep Output and Beep when Pass condition detected Operate Stop Pass Fail test stopped press to run P Start Pass Fail test running press to stop ie Go to the next men o to the ne enu page The Pass Fail menu table Page 2 2 2 2 Ae 4 Back to the previous menu page Stop ON Stop test when output occur output OFF Continue test when output occur Go to Mask menu 2 2 r Lak Back to the previous menu page Mask setting 58 DSO1000 SERIES HANDHELD OSCILLOSOPE Press Utility Pass Fail Mask Setting to go to the following menu The Mask menu Page 1 2 Horizontal te Location re ci i Figure 2 46 The Mask menu The Mask menu Page 2 2 Figure 2 47 The Mask menu The Mask setting menu table Page 1 2 erica eena clearance o ewon O Fonzo Sethorionial dearance otre wavom create reste atest mask according tothe above demane Location Internal Store created test mask into internal External memory External tir Go to th t o to the next menu page The Mask setting menu table Page 2 2 When the save as internal memory 2 2 ei Back to the previous menu page Sae Store created test mask into internal memory load Recall mask setting fil
35. ference Waveforms are saved waveforms to be selected for display The reference function will be available after saving the selected waveform to non volatile memory Press M R button to display the Reference waveform menu Select menu Enable gt ON to enter reference function window The reference function window is displayed in Figure 2 15 33 USER S MANUAL 1060 1200 1600 1600H Figure 2 15 The reference function window Internal Press M R REF Internal and go to the following menu REF menu when using internal memory RER Enable SOUFCE Location Figure 2 16 The Internal menu REF menu table when using internal memory Enable ON Turn on REF OFF Turn off REF Select CH1 as REF channel Source Select CH2 as REF channel Select MATH as REF channel 34 DSO1000 SERIES HANDHELD OSCILLOSOPE Internal Select memory location in scope Location External Select memory location out scope REF menu table when using external memory Enabl ON Turn on REF oe OFF Turn off REF S rc CH1 Select CH1 as REF channel CH2 Select CH2 as REF channel Internal Select inner memory location Location A External Select outer memory location 2 Go to the next menu page gt pag External Press MMR REF External and go to the following menu The External REF menu Page 1 2 Enable Source Location OFF A CH1 Xf External Figure 2 17 The External menu The External REF menu Page
36. ge 1 5 Turn off Frequency or Counter F C Turn on Frequency Counter Turn on Counter Ea Turn on the multimeter OFF Turn off the multimeter Display T Show Display menu page i e Go to the next menu page 54 DSO1000 SERIES HANDHELD OSCILLOSOPE 1 5 i Go to the next menu page The Utility menu table Page 2 4 and Page 2 5 2 4 Back to the previous menu page Back to the previous menu page Pass Fail Go to Pass Fail menu page Go to Record menu page Select languages Language More languages may be added in later firmware versions Le Go to the next menu page Go to the next menu page The Utility menu table Page 3 4 and Page 3 5 ee Back to the previous menu page aa Back to the previous menu page 5Min 10Min 20Min Set the shut down time 30Min Infinite ON OFF Turn beeper sound on off Calibrate Calibrate the oscilloscope 34 Go to the next menu page 55 USER S MANUAL 1060 1200 1600 1600H 3 5 a Go to the next menu page The Utility menu table Page 4 4 and Page 4 5 4 5 E peme O Save Save the system configuration when shut down Update Woo Update the system System Info PF Show the information of the system 2 oo Go to the first previou menu page Lo Go to the next menu page The Utility menu table Page 5 5 5 5 Sf Back to the previous menu page IO Set Ps Go to the IO Set menu Page I Go the the first previous menu page Calibrate
37. graph indictor 7 DC or AC Measurement mode control 8 Absolute relative magnitude measuring control The sign expresses the absolute magnitude measuring control and represents the relative magnitude measuring control 9 Manually or automatically measuring range control Operating the Multimeter If you are in the scope mode window press OSC DMM key the oscilloscope will switch to the multimeter mode window Then the screen will display the measure mode window that was in use the last time before you quit multimeter measure When you switch to the multimeter measurement the first time the default measure mode is DC voltage mode Measuring Resistance Values To measure a resistance do the following 1 Press the R key and then resistance measurement window appears on the screen 2 Insert the black lead into the COM banana jack input and the red lead into the V Q C banana jack input 3 Connect the red and black test leads to the resistor The resistance value is shown on the screen in Ohm Then the screen will look like the following figure 4 2 82 DSO1000 SERIES HANDHELD OSCILLOSOPE 8 5 1 15 WA Figure 4 2 Resistance Measurement Making a Diode Measurement To make a measurement on the diode do the following 1 Press the diode key and a diode symbol appears at the top of the screen 2 Insert the black lead into the COM banana jack input and the red lead into the viac banana jac
38. he red lead into the V Q C banana jack input 3 Connect the red and black test leads to the resistor The resistance value is shown on the screen in Ohm 4 When the reading leveling off press F1 key and then A is displayed on the top of the screen The saved reference value is displayed beside Then the screen will look like the following figure 4 12 92 DSO1000 SERIES HANDHELD OSCILLOSOPE Manual Figure 4 12 Relative Measurement Selecting Automatic Manual Range Adjustment The default range mode of the instrument is automatic range Suppose you are using the DC voltage mode to switch to the manual range perform the following steps 1 Press F3 key to enter the manual range mode and then Manual is displayed on the top of the screen 2 Under the manual range mode the measuring range is increased by a stage when pressing F4 key each time and when reaching the highest stage it jumps to the lowest stage by pressing F4 key once again 3 Press F3 key to switch back to the automatic range mode and then Auto is displayed on the top of the screen Attention capacitance measurement without manual range mode Then the screen will look like the following figure 4 13 93 MANUAL 1060 1200 1600 1600H Manual mlm a 7 l Figure 4 13 The Manual Range Mode 94 DSO1000 SERIES HANDHELD OSCILLOSOPE Chapter 5 Troubleshooting 1 The oscilloscope cannot start 1 Check the p
39. horizontal trigger time Shows location of the current waveform in the memory Shows the trigger position in the memory Shows the trigger mode Shows the trigger source Shows the trigger level Shows the power The center of current waveform window 10 CH1 waveform 11 The trigger level symbol 12 The grid 13 CH2 waveform 14 Shows the time base 15 Shows running staturs 16 CH1 CH2 17 Shows the coupling 18 Shows the voltage div 19 CH2 mark 20 CH1 mark 21 Shows the trigger position in current waveform window USER S MANUAL 1060 1200 1600 1600H Input Connections See the following Figure 1 4 Figure 1 4 Input Connections Description 1 The power adapter is supplied for AC power supply and battery recharging 2 Multi meter input jacks including four circular banana jacks The four circular jacks are used for voltage resistance mA range current and A range current inputs 3 Multi meter test lead 4 Oscilloscope probes 5 Oscilloscope input channels DSO1000 SERIES HANDHELD OSCILLOSOPE Function Check Perform this quick functional check to verify that your oscilloscope is operating correctly 1 Turn on the instrument Use the power adapter designed for your oscilloscope only Use a power source that delivers 100 to 240 VACRMS 50Hz Turn on the oscilloscope 2 Input a signal to a channel Set the attenuation switch on the probe to X10 and connect the probe to CH1 on
40. ing 1 Press the V key and DC appears at the top of the screen 2 Insert the black lead into the COM banana jack input and the red lead into the V Q C banana jack input 3 Connect the red and black leads to the measured points and the voltage value of measured points is displayed on the screen Then the screen will look like the following figure 4 6 86 DSO1000 SERIES HANDHELD OSCILLOSOPE Auto xia mV Figure 4 6 DC voltage Measurement Making an AC Voltage Measurement To measure the AC voltage do the following 1 Press the V key and DC appears on the screen 2 Press the F1 key and AC appears on the screen 3 Insert the black lead into the COM banana jack input and the red lead into the V Q C banana jack input 4 Connect the red and black leads to the measured points and the AC voltage value of measured points will be displayed on the screen Then the screen will look like the following figure 4 7 87 MANUAL 1060 1200 1600 1600H Figure 4 7 AC voltage Measurement Making a DC Current Measurement To measure a DC current which is less than 600 mA do the following 1 Press the A key and then DC appears on the screen The unit on the main reading screen is mA Press F2 to switch the measurement between mA and 10A 600mA is acquiescently 2 Insert the black lead into the COM banana jack input and the red lead into the mA banana jack input 3 Connect the red and black lead
41. isplayed on the oscilloscope 4 Repeat if necessary WARNNING To avoid electric shock while using the probe be sure the perfection of the insulated cable and do not touch the metallic portions of the probe head while it is connected with a voltage source To display a signal automatically The oscilloscope has an Auto feature that automatically sets up the oscilloscope to best display the input signal Using Auto requires signals with a frequency greater than or equal to 50 Hz and a duty cycle greater than 1 Press the AUTO button the oscilloscope turns on and scales all channels that have signals applied and it selects a time base range based on the trigger source The trigger source selected is the lowest numbered input that has a signal applied The oscilloscope has two channels input Connect a signal to the CH1 input 1 Connect a signal to the oscilloscope 2 Press AUTO The oscilloscope may change the current setting to display the signal It will automatically adjust the vertical and horizontal scaling the trigger coupling type position slope level and mode settings MANUAL 1060 1200 1600 1600H Using the Oscilloscope This part provides a step by step introduction to the scope functions The introduction does not cover all of the capabilities of the scope functions but gives basic examples to show how to use the menus and perform basic operations Turn on the oscilloscope Connect oscilloscope to AC
42. k input 3 Connect the red and black leads to the diode and the voltage value of the diode is displayed on the screen in volt Then the screen will look like the following figure 4 3 83 MANUAL 1060 1200 1600 1600H a aes I V Figure 4 3 Diode Measurement To perform an On off test do the following 1 Press the On off key and then On off indictor appears on the top of the screen 2 Insert the black lead into the COM banana jack input and the red lead into the V Q C banana jack input 3 Connect the red and black leads to the tested points If the resistance value of the tested points is less than 30 Q you will hear beep sound from the test tool Then the screen will look like the following figure 4 4 84 DSO1000 SERIES HANDHELD OSCILLOSOPE a ee O Figure 4 4 On off Measurement Making a Capacitance Measurement To measure a capacitance do the following 1 Press the C key and a capacitor symbol appears on the top of the screen 2 Insert the black lead into the COM banana jack input and the red lead into the V Q C banana jack input 3 Connect the red and black leads to the capacitor and the capacitance value is displayed on the screen in pF or nF Then the screen will look like the following figure 4 5 85 MANUAL 1060 1200 1600 1600H 5 S li G Figure 4 5 Capacitance Measurement Making a DC Voltage Measurement To measure a DC voltage do the follow
43. lf to trigger When forcing invalid triggers the oscilloscope cannot synchronize the waveform and the waveform seems to roll across the display If valid triggers occur the display becomes stable on the screen Any factor results in the un stability of waveforms can be detected by Auto Trigger such as the output of Power supply NOTE When horizontal control is set more than 50 ms div Auto mode allows the oscilloscope to capture without trigger signal m Normal The Normal mode allows the oscilloscope to acquire a waveform only when it is triggered If no trigger occurs the oscilloscope keeps waiting and the previous waveform if any will remain on the display m Single In Single mode after pressing the RUN STOP key the oscilloscope waits for trigger While the trigger occurs the oscilloscope acquires one waveform then stop Save Recall Waveforms and Setups Press the Save Recall button the interface menu for settings shows as follows The Save Recall Menu Table Store or recall waveform Store or recall instrument setups Create or delete bitmap files Create or delete CSV files Recall factory setups Internal P Go to menu for internal memory operation 48 DSO1000 SERIES HANDHELD OSCILLOSOPE External Po Go to menu for external memory operation Wave The Wave menu Type f External Figure 2 35 The Wave menu The Wave menu table intemal fo Go to menu for internal memory opera
44. lf displays the main waveform window and the lower half displays an expanded portion of the main waveform window This expanded portion of the main window is called the ALT Mag window Two blocks shadow the upper half The un shadowed portion is expanded in the lower half The key TIME DIV control the size and position of the ALT Mag The symbol at the right bottom of the screen means the main time base and the symbol on the center bottom means the ALT Mag time X Y Format This format is useful for studying phase relationships between two signals CH1 in the 39 USER S MANUAL 1060 1200 1600 1600H horizontal axis X and CH2 in the vertical axis Y Figure 2 25 X Y display format The following modes or functions will not work in X Y format m Automatic Measurements m Cursor Measurements m REF and MATH Operations m Horizontal Position m Trigger Controls Set Trigger System The trigger determines when the oscilloscope starts to acquire data and display a waveform When a trigger is set up properly it can convert unstable displays or blank screens into meaningful waveforms When the oscilloscope starts to acquire a waveform it collects enough data so that it can draw the waveform to the left of the trigger point The oscilloscope continues to acquire data while waiting for the trigger condition to occur After it detects a trigger the oscillosc ope continues to acquire enough data so that it can draw the waveform to th
45. nals can be detected through setting up the pulse width condition Press TRIG F1 Pulse button to show the pulse trigger menu as the following table The Pulse Trigger menu Page 1 2 Mode Source When Figure 2 27 The Pulse Trigger Menu The Pulse Trigger menu Page 2 2 t Sweep HF Reject aye Figure 2 28 The Pulse Trigger Menu The Pulse Trigger Table Page 1 2 a Define CH1 or CH2 as trigger signal Pulse width more than selecting pulse condition Pulse width less than selecting pulse condtion Pulse width equal to selecting pulse condition Pulse width more than selecting pulse condition Pulse width less than selecting pulse condition Pulse width equal to selecting pulse condition Setting Set required pulse width 1 2 42 DSO1000 SERIES HANDHELD OSCILLOSOPE The Pulse Trigger Table Page 2 2 LJ Back to the previous menu page Acquire waveform even no trigger occurred Acquire waveform when trigger occurred When trigger occurs acquire one waveform and then stop Set the trigger level to the center of the signal Back to the previous menu page Note The Pulse width adjust range is10ns 10s When the condition is met it will trigger and acquire the waveform ALT Alternative Trigger Setting When alternative trigger is on the trigger sources come from two vertical channels This mode can be used to observe two non related signals You can choose two different trigg
46. onent choose AC Coupling on the source signal 2 To reduce random noise and aliases components in repetitive or single shot events set the oscilloscope acquisition mode to average 3 To display FFT waveforms with a large dynamic range use the dBVrms scale The dBVrms scale displays component magnitudes using a log scale FFT Window The oscilloscope provides four FFT windows Each window is a trade off between frequency resolution and amplitude accuracy It depends on the desired 32 DSO1000 SERIES HANDHELD OSCILLOSOPE measurement and the source signals characteristics to determine the window to use Use the following guidelines to select the best window The FFT Window table Best frequency resolution and Transients or bursts the signal worst magnitude resolution This levels before and after the is essentially the same as no event are nearly equal Equal Rectangle window amplitude sine waves with fixed frequencies Broadband random noise with a relatively slow varying spectrum Better frequency poorer Sine periodic and narrow band Hanning magnitude accuracy than random noise Transients or Rectangular Hamming has bursts where the signal levels Hamming slightly better frequency before and after the events are resolution than Hanning significantly different Best magnitude worst frequency Single frequency waveforms to Blackman i resolution Find higher order harmonics 8 REF Re
47. ower cable connection 2 Ensure the power switch is turned on 3 After the above inspection restart the oscilloscope 4 If the problem still remains please contact us for help 2 The measurement result is 10 times higher or lower than the value expected Check if the probe attenuation is the same as the channel attenuation 3 The waveform is displayed on the screen but is not stable under the oscillosco pe mode 1 Check the Trigger Source and notice if it is set to the channel in use 2 Check the Trigger Type 4 When select the average sampling in the sampling mode or select a long display time in the display mode under the oscilloscope the display speed is slow It is normal in the above case 95 USER S MANUAL 1060 1200 1600 1600H Chapter 6 Specifications Vertical DSO1060 60MHz DSO1200 200MHz Bandwidth DSO1600 600MHz DSO1600H 600MHz DSO1060 5 8ns DSO1200 1 7ns Rise Time DSO1600 0 58ns DSO1600H 0 58ns Input Impedance Resistance 1M Capacitance 15pF DSO1060 10mv div to 5v div DSO1200 10mv div to 5v div Input Sensitivity DSO1600 1mv div to 5v div DSO1600H 1mv div to 5v div Horizontal DSO1060 250MSa s DSO1200 500MSa s Sampling DSO1600 1GSa s DSO1600H 2GSa s Equivalent Sampling 50GSa s one oe 5ns div 1000s div eae ee o 2ns div 1000s div Time Base eee 1ns div 1000s div DSO1600H Ins div 1000s div sts 1ns div 1000s div Trigger 96 DS
48. s to the measured points and the DC current value of measured points will be displayed on the screen Then the screen will look like the following figure 4 8 88 DSO1000 SERIES HANDHELD OSCILLOSOPE Figure 4 8 DC current Measurement for 600 mA To measure a DC current which is larger than 600 mA do the following 1 Press the A key and then DC appears on the screen The unit on the main reading screen is mA 2 Press F2 key to switch to 10A measurement the unit on the main reading screen is A 3 Insert the black lead into the COM banana jack input and the red lead into the 10A banana jack input 4 Connect the red and black leads to the measured points and the DC current value of the measured points will be displayed on the screen 5 Press F2 to return to 600 mA measurement Then the screen will look like the following figure 4 9 89 MANUAL 1060 1200 1600 1600H LOL A Figure 4 9 DC Current Measurement for 10A Making an AC Current Measurement To measure an AC current which is less than 600 mA do the following 1 Press the A key and then DC appears on the screen The unit on the main reading screen is mA and mA will display on the bottom of the screen press F2 to switch the measurement between mA and 10A 600mA is acquiescently 2 Press the F1 key once and AC will display on the bottom of the screen 3 Insert the black lead into the COM banana jack input and the red lead into the mA ban
49. t Off Press CH1 F5 F4 ON to set up bandwidth limit to ON status It will reject the frequency component higher than 20MHz Press CH1 F5 F5 F2 ON to set up bandwidth limit to ON status It will reject the frequency component higher than 100MHz This function is not used in DSO1060 The waveform is displayed as Figure 2 10 28 DSO1000 SERIES HANDHELD OSCILLOSOPE CHi ARAS LA E Time 20 00ns Figure 2 10 Turn BW limit On 6 Math Setting The mathematic functions include add subtract multiply division and FFT for CH1 and CH2 The mathematic result can be measured by the grid and the cursor The mathematic window is displayed as figure 2 11 The Math menu Page 1 2 Enable Operate Source A Source B 1v2 b Figure 2 11 The Math menu The Math menu Page 2 2 29 USER S MANUAL 1060 1200 1600 1600H q olti Div Invert Probe ss Figure 2 12 The Math menu The Math menu setting table Enable ON Turn on math OFF Turn off math Add source A and source B Subtract source B from source A Operate Multiply source B by source A Divide source A by source B Fast Fourier Transform mae Define CH1 or CH2 as source A CH1 Source B CH2 Define CH1 or CH2 as source B 2 2 a eee Se Invert the MATH waveform OFF Waveform display normal Select one according the probe attenuation Probe factor to ensure a correct vertical scale reading ee B
50. t Probe Attenuation The oscilloscope allows adjusting the probe attenuation scale factor correspondingly in the channel operation menu in order to comply with the probe attenuation scale The attenuation factor changes the vertical scaling of the oscilloscope so that the measurement results reflect the actual voltage levels at the probe tip To change or check the probe attenuation setting press the CH1 or CH2 button according to which channel in using Toggle the Probe soft button to match the attenuation factor of the probe This setting remains in effect until changes again Enable Coupling Probe Figure 2 6 Probe Setting 25 USER S MANUAL 1060 1200 1600 1600H 4 Invert a waveform The displayed waveform reverses 180 degrees relatively to the ground potential Press CH1 or CH2 F5 F3 to turn on off the Invert Time 56 YoltiDiv Invert Bw Lirnit Figure 2 7 Turn Invert off 26 DSO1000 SERIES HANDHELD OSCILLOSOPE Time 500 015 YoltiDiv Invert MY Limit Figure 2 8 Turn Invert on 5 Set Band Width Limit With CH1 taken for example input a signal containing high frequency component Press CH1 F5 F4 0FF to set up bandwidth limit to OFF status The oscillosc ope is set to full bandwidth and passing the high frequency component in the signal The waveform is displayed as Figure 2 9 27 USER S MANUAL 1060 1200 1600 1600H Figure 2 9 Turn BW limi
51. t and moves the Reset z trigger point to the horizontal center of the screen ON Turn on ALT Mag ALT Mag Turn off ALT Mag Holdoff ON Turn on the Holdoff time OFF Turn off the Holdoff time 1 TIME DIV Use this button to select the horizontal time div scale factor for the main TIME DIV Figure 2 21 The TIME DIV button 2 POSITION Press this button to adjust the horizontal position of all channel waveforms The resolution of this control varies with the time base POSITIONS Figure 2 22 The POSITION button 37 USER S MANUAL 1060 1200 1600 1600H Figure 2 23 The horizontal Time base marks Marks Indicator 1 The current running status 2 The trigger position in the memory 3 The current waveform window s position in the memory 4 The trigger position in the current waveform window 5 The horizontal time base main time base ALT Mag The ALT Mag is a magnified portion of the waveform window Use ALT Mag to locate and horizontally expand part of the main waveform window for a more detailed higher horizontal resolution analysis of signal The ALT Mag time base setting cannot be set 38 DSO1000 SERIES HANDHELD OSCILLOSOPE Figure 2 24 ALT Mag Mode Description 1 Wave to be horizontally expanded 2 The magnified Wave 3 The time base of ALT Mag 4 The main time base The following describes the ALT Mag display The screen is divides into two parts The upper ha
52. t only allow you to use some of the functions directly but also bring up the manual keys on the screen which enable the access to many measurement features associated with advanced functions mathematics and reference or to run control features USER S MANUAL 1060 1200 1600 1600H Figure 1 1 Oscilloscope Front Panel DSO1000 SERIES HANDHELD OSCILLOSOPE Figure 1 2 Front Panel Description Description 1 LCD Display 2 F1 F5 Sets or switch options for the menu 3 Arrow Keys 4 HORI Shows Horizontal menu 5 TRIG Shows Trigger menu 6 LEVEL Adjust the trigger level 7 RUN STOP key for running or stopping the operation 8 AUTO Be used for auto setting under the oscilloscope operation mode 9 USER S MANUAL 1060 1200 1600 1600H 9 TIME DIV Decrease or Increase the time base 10 11 12 13 14 15 16 17 18 19 20 21 POSITION Adjust the horizontal trigger position CH2 Shows the CH2 menu VOLTS Decrease or Increase the voltage div CH1 Shows the CH1 menu M R Shows the Math or REF menu DMM Buttons The DMM control buttons DMM SCOPE Switch DMM or Scope function MENU ON OFF Turn on off the menu SAVE RECALL Shows SAVE or RECALL menu MEAS Shows Measurement menu UTILITY Shows Utility menu CURSOR Shows Cursor menu Display screen Figure 1 3 LCD Display screen Description 1 Shows Brand DSO1000 SERIES HANDHELD OSCILLOSOPE Shows
53. temperature is not al lowed to exceed the permissible value given in technical specification Note No hazard will occur even connecting the charger for a long time e g during a whole weekend The instrument can automatically switch to slowly charging status Replacing the Lithium Battery Unit It is usually not required to replace the battery unit But when it is required to replace it only qualified personnel can carry out this operation and only use the same specification lithium battery 101 USER S MANUAL 1060 1200 1600 1600H 102
54. tion extemal Go to menu for external memory operation Setup The Setup menu Type poset kantema I external Figure 2 36 The Setup menu The Setup menu table internal Go to menu for internal memory operation External Po Go to menu for external memory operation Bitmap The Bitmap menu 49 USER S MANUAL 1060 1200 1600 1600H Type Figure 2 37 The Bitmap menu The Bitmap menu table Etema fo Go to menu for external memory operation CSV The CSV menu Type Figure 2 38 The CSV menu The CSV menu table extemal Go to menu for external memory operation Factory The Factory menu Type Figure 2 39 The Factory menu The Factory menu table DSO1000 SERIES HANDHELD OSCILLOSOPE toaa f Recall factory setups or files Internal Memory Press SAVE RECALL Internal to go to the following menu Setup_01 Internal a Set up the location of files in internal memory Setup_15 Load Recall waveform files and setup files from the internal memory location Save Save waveform files and setup files to the internal memory location External Memory Press SAVE RECALL External to go to the following menu Delete File Po Delete file tos o we Load device File system as following 51 MANUAL 1060 1200 1600 1600H Delete File A Lood Figure 2 40 File System Factory The oscilloscope has default
55. ty Notice 1 Safety Terms and Symbols Terms in this manual These terms may appear in this manual WARNING Warning statements identify conditions or practices that could result in injury or loss of life CAUTION Caution statements identify conditions or practices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER indicates an injury hazard may be immediately accessible WARNING indicates an injury hazard may be not immediately accessible CAUTION indicates that a potential damage to the instrument or other property might occur Symbols on the Product These symbols may appear on the product A A m 4 Hazardous Refer to Protective Grounding Test Voltage Instructions Earth Terminal Terminal Grounding of Chassis Terrninal 2 General Safety Information Carefully read the following safety information in order to avoid any personal injury or damage on this product or any products connected with it Review the following safety precautions carefully before operate the device to avoid any personal injuries or damages to the device and any products connected to it To avoid potential hazards use the device as specified by this user s manual only To Avoid Fire or Personal Injury a Use Proper Power adapter Use only the power cord specified for this product and certified for the country of use USER S MANUAL 1060 1200 1600 160
56. u Play Mode The Record menu Play Mode Page 2 2 gt Start Frame Cur Frame End Frame Figure 2 51 The Record menu Play Mode The Record menu table Play Mode Page 1 2 Operate Start Play stopped press to start playback Stop Press to stop playing ON Interval lt 10 0ms 20s gt _ Set interval time to play back 61 USER S MANUAL 1060 1200 1600 1600H 1 2 s Go to the next menu page S comerem The Record menu table Play Mode Page 2 2 2 2 emf Back to the previous menu page Start Frame lt 1 1000 gt Set start frame lt 1 1000 gt Select current frame to be played lt 1 1000 gt Set End frame gt _ Back to the previous menu page Storage Store recorded waveforms to non volatile memory according to the setup frames The Record menu Storage Mode Page 1 2 Wode Start Frame End Frame Location oe ofp 1 ie Figure 2 52 The Record menu Storage Mode The Record menu Storage Mode Page 2 2 Figure 2 53 The Record menu Storage Mode The Record menu Storage Mode Page 1 2 lt 1 1000 gt Set first frame to be saved Frame 62 DSO1000 SERIES HANDHELD OSCILLOSOPE lt 1 1000 gt Set end frame to be saved Location internal Set up Store location External 1 2 Go to the next menu page The Record menu when the save to Internal memory Storage Mode Page 2 2 seve __ Sveresrded waveform oneal memon sion
Download Pdf Manuals
Related Search
Related Contents
Yuraku 17" LCD Monitor NewAir AWR-520SB Instructions / Assembly Owner`s Manual GUÍA DEL USUARIO QDA55の取扱説明書をダウンロード Data Sheet Manual del Usuario Congratulations on your purchase of the advanced and compact LG Multimedia Interface Bedienungsanleitung Instruction Montage- und Bedienungsanleitung Assembly and Copyright © All rights reserved.