1. Steps 1 to 5 and Step 9 do not change mode settings You change modes by sending specific DMX values to the red LEDs in steps 6 to 8 If a mode does not need to be changed in steps 6 to 8 send the Ignore value 0 zero in the step concerned Regardless of whether panels are set to 8 or 16 bit mode you must send the DMX values to the LEDs for the specified colors on the following channels Send the values for red LEDs on channels 1 7 19 and 43 Send the values for blue and green LEDs on channels 3 5 9 11 45 and 47 EvenLED panels must be interconnected using DMX THROUGH connectors The DMX OUT connectors do not relay mode setting data Any Martin DMX Thief devices on the DMX link must be bypassed temporarily by disconnecting the DMX cable connectors from their DMX IN and DMX OUT sockets and connecting the DMX cable connectors directly together Operation 21 22 Mode setting procedure To set the modes in EvenLED panels T 2 3 Power all panels off See Table 2 Set the controller to send the panel configuration enable DMX values in Step 1 Power panels on When panels receive the panel configuration enable values at power on they will display their software versions and their mode settings in an alternating sequence until they receive the DMX values for Step 2 from the DMX controller Wait minimum 2 seconds then send the DMX values for Steps 2 to 9 Steps 2 to 8 must last exactly one seco
2. Mixing EvenLED panels and other types of fixture on a DMX link eesoooon 12 System layouts nds enticed a con se ehe 13 Connecting the system i o es cipe e rwv ee 14 Connectors overview ll le en va ka ke remm ther 14 AG POWER kurs a O Sather n She Zan per ye eat ae RUBER Vu A AA eos ea p 15 Connecting TO POWER ti e 16 Relaying power between panels oooooococco eens 16 Current overload safety 0 0 0 cece kaka n an ka ma ka knn 17 Connecting the DMX control data link Isle ke ka ken ka ka ka kan an IR en 17 Connection pinouts ici hed bd Ra lila talas cad 17 Making data connections e ll e seks n ka E a kw n kn a kon a I n kon kon ko nn 18 So A ERSTER OR E TET A ee 19 Powering on and Startups x 23 28 04 cer eels ace ead ERRARE ANI NER AURA E ERU Ete 19 DMX controls elc EOS AS Rn ER ea kes Pee ues 19 16 and 8 bit DMX control modes 0 0 ene 19 LED Map ise be Sabie rum e bts uerb duet qe per e Ret 19 DMX protocols Ree Eos e D Rm RUN e EA Re A ER RR CR REI 20 Software version and mode settings display tee ee ve ka eese 20 Configuring panels using a DMX controller 0 0 0 0 ect eh 21 Mode setting procedure e nunana een nen 22 Mode setting DMX sequence lel len RR I I rt rt 23 Using back projection SCreensS 1 2 6 e e kn konn kon a 23 Using DMX Thief IM veh eases a s e aet ar enc dre tog b E ats
3. The EvenLED s aluminum housing can be cleaned with a cloth that is slightly dampened but not wet with a solution of water and a mild detergent such as car shampoo To clean the housing 1 Isolate the panel from AC power and allow it to cool for 20 minutes 2 Gently wipe away dirt and dust with the damp cloth 3 Allow any moisture to dry before reconnecting to power Software installation 24 It may be necessary to upload new software firmware to the EvenLED if you believe that the product has a software related fault or if you want to update to a newer version Software updates are available from the Martin website http www martin com and can be installed via the DMX data link with the EvenLED Software Uploader available from Martin P N 90758097 See the separate EvenLED Software Uploader user manual for details EvenLED user manual Troubleshooting Problem Probable cause s Remedy Panel is completely dead One or more panels responds incorrectly to control or does not respond at all LEDs cut out intermittently No power to panel Check power and connections Current overload protection circuit activated Isolate panel from power Contact Martin for assistance Fuse blown Fault or interference on DMX link Incorrect panel addressing Fuse is not user replaceable Isolate panel from power Contact Martin for assistance Inspect connections and cables Correct poor connect
4. DMX channels 1 96 only We will also assume that commands from the DMX controller to the first EvenLED panel on the DMX link are sent on channels 1 96 other channels can be used if a Martin DMX Thief is connected on the control data link Grouped control using DMX THROUGH All EvenLED panels connected using DMX THROUGH outputs respond to the same DMX commands and behave identically The DMX THROUGH output relays the DMX signal exactly as it is received by the panel without any processing This lets you relay identical DMX commands from one panel to the next so that all connected panels can be controlled as a group using DMX channels 1 96 Independent control using DUX OUT EvenLED panels connected using DMX OUT outputs respond to DMX commands on different channels and behave differently To explain how this works let us assume that you have two EvenLED panels on the DMX link To send separate commands to the second panel so that you can control this panel independently of the first connect the second panel to the first panel s DMX OUT output The controller can then send commands to the first panel on channels 1 96 and to the second panel on channels 97 192 Because the second panel like all EvenLED panels will only respond to commands it receives on channels starting at channel 1 the DMX signal at the first panel s DMX OUT output is processed by subtracting 96 channels and re addressing the commands sent from the
5. LED mapping can be reconfigured and LEDs can be controlled in groups using the Martin DMX Thief accessory see Using DMX Thief on page 23 Figure 12 LED mapping Operation 19 DMX protocols The tables below give control details for each individual LED in the EvenLED panel 16 bit control Start code 0 Channel Value Percent Function 1 Red 0 255 0 100 Intensity 0 gt 100 2 Red fine 0 255 0 100 Fine adjustment 3 Green 0 255 0 100 Intensity 0 10095 4 Green fine 0 255 0 100 Fine adjustment 5 Blue 0 255 0 100 Intensity 0 gt 100 6 Blue fine 0 255 0 100 Fine adjustment 8 bit control Start code 0 Channel Value Percent Function 4 Red 0 255 0 10095 Intensity 0 10095 2 Green 0 255 0 100 Intensity 0 10095 3 Blue 0 255 0 100 Intensity 0 10095 The EvenLED is supplied set up for 16 bit control by default If you want to reconfigure panels for 8 bit control see Configuring panels using a DMX controller on page 21 Software version and mode settings display EvenLED panels show their software versions and mode settings when powered on if they are configured to do so as described under Configuring panels using a DMX controller on page 21 Software version display EvenLED panels display their software as a binary 80 40 20 10 10s number on their LEDs See Figure 13 The top row of LEDs shows t
6. OUT DMX IN DMX OUT IN E IN o III w DMX address 001 DMX address 097 DMX address DMX address 001 DMX address 097 DMX address 1 co w Figure 8 System layouts Warning The above diagram and the text in the section that precedes it cover the DMX data link and describe the limitations imposed by the DMX system only Do not confuse them with power connections which are subject to maximum current limitations Refer to AC power on page 15 for details of establishing power circuits Physical installation 13 Connecting the system Connectors overview 14 Panel back connectors DMX Out Power Through DMX Through Power In DMX In Figure 9 Connections See Figure 9 The EvenLED panel must be connected to power and to a DMX control data link using the following connectors DMX connectors 5 pin XLR DMX IN accepts a DMX 512 control signal It reads DMX commands sent to the first incoming DMX address and assigns that as the starting address for the EvenLED panel DMX OUT can be used to continue the DMX link to another EvenLED panel Use this output for independent control of different panels DMX THROUGH can also be used to continue the DMX link to another EvenLED panel but use this output for grouped DMX control of panels in which panels share the same DMX address respond to the same DMX commands and behave identically Power connectors The blue Neutrik PowerCon
7. XLR Electrical AC power nenn AA REIR RYE e p Ee s EA ER RS 100 240 VAC nominal 50 60 Hz Power supply unit Integrated auto sensing multi voltage with integral current overload protection Standby power see ns ad eI ey Xe a eeu bear ee re ee A RU dede 24 W Earth leakage current ll ll ll len l a nn lel mt 1 mA Main fuse not user replaceable el el n kek kn n II nna F6 3 A EvenLED user manual Typical power and current Maximum total power consumption 0 2 0 cece n ka n kn n kon n ka n kon n kon n uh 155 W TOON SO AZ il ee ee a a RE ae Bere 151 W 1 6 A PF 0 978 TOON Aog cm 151 W 1 6 A PF 0 988 110 V GOLAZ is y nx a ERE ee RERO PORE CU RR GE Ege RO RR ee 151 W 1 4 A PF 0 985 120 V O0 HZ scs ode bes MERKUR Ae ewe V Wu ewm Mies Ri rd ou 151 W 1 3 A PF 0 981 208 V 60 Hz psina bedded a ae poke A ia 151 W 0 8 A PF 2 0 915 230 V S0 HZ coreo Eie sioe dr zu opor un saborea meres 152 W 0 8 A PF 0 892 ZAON SO FIZE 3 2 cove Emm 152 W 0 7 A PF 0 887 Measurements per panel made at nominal voltage with all LEDs at full intensity Allow for a deviation of 10 Thermal enm Convection Maximum ambient temperature Ta MAX eee er ler ker Ih 40 C 104 F Minimum ambient temperature Ta min lle 5 C 41 F Maximum surface temperature steady state Ta 40 C 1 eee 80 C Total heat dissipation calculated 1096 lille 530 BTU hr Approvals
8. are intended to support and that they conform to local building and safety regulations Install as described in this manual a secondary attachment e g a safety cable that is approved by an official body such as T V as a safety attachment for the weight of all the fixtures it secures The safety cable must comply with EN 60598 2 17 Section 17 6 6 and be capable of bearing a static suspended load ten times the weight of the fixture EvenLED user manual Contents DIMGCNSIONSe coe ks arenes ae Narain tmr oM M te a Siete ET 2 Sarety Informations ce teo Pu eae whe ed ete ie ete eer ur res 3 Introd de HO Db Co dn En ote tob or One nie la este Tea 6 Unpacking cata LEA het ee A iii 6 Using for thefirst UME nr ex roma A Cea hae aa ae URIM eee ean 6 Physical installation tere eet ne 7 Location and orientation e tee e e konn koma n kon n knn 7 Assembly and mounting ket emita RR ar eng de a a ER RULR le E D a Mad n ap eae A 8 Assembling the panel and frame II el l kl n kn kk n n kn n ka a kk n ko n kaa n ka kon nn 8 Mounting the EvenL ED kita tek ia done nen pe Rp a pee eee B L EUR Bice en a 8 Planning the DMX control system ll ll l ll kl Lk kn n kl n kk ka n ka n kn n kaa n ka n kon konn anan 11 Grouped and independent panel control L ll Lel lune kn kn n a kn kk a koka n ka konn n nn knn n 11 Cable and link layout details elle ten en ka ka ka a en an ka ma nan aa I kan 12
9. chain Install as described in this user manual safety attachments that can hold a static load at least ten times heavier than the total weight they must secure and are approved for this weight by a technical standards organization such as TUV Warning Maintain a distance of minimum 5 cm 2 inches from adjacent surfaces Make sure that there is unrestricted airflow around the air vents in the rear surface of the panel Warning Make sure that it is impossible for LEDs to be viewed from a distance of less than 40 cm 16 inches unless a diffuser or back projection screen is installed in front of them If a diffuser front or back projection screen is installed in front of the LEDs such that it is impossible to distinguish individual LEDs there is no eye hazard at any distance The EvenLED is rated IP20 and is for indoor use only Do not expose it to water or moisture The EvenLED requires free and unobstructed airflow around it to ensure adequate cooling Do not use the panel in a confined or unventilated space Allow 5 cm 2 inches free space around the panel Install the panel at least 5 cm 2 inches away from any combustible materials wood paper etc and well away from any flammable materials Panels reach temperatures up to 80 C 176 F Restrict public access or locate panels so that they cannot accidentally be touched Physical installation 7 Assembly and mounting Assembling the panel and frame To assemble the EvenLED
10. controller on channels 97 192 so that they are relayed to the second panel on channels 1 96 To sum up the DMX OUT output relays the DMX signal after subtracting the number of channels used by the panel and address shifting the remaining DMX channels so that they start at channel 1 This lets you relay different DMX commands from one panel to the next so that panels can be controlled independently Maximum number of panels on the DMX link Identical grouped control In identical grouped control using DMX THROUGH outputs up to 32 panels can be connected in one chain on the DMX link The limit of 32 panels is a function of the electrical characteristics of DMX512 If more than 32 panels are to be used in a single DMX512 universe the chain can be extended using an amplifier splitter such as the Martin Opto Splitter Independent control In independent control using DMX OUT outputs the maximum number of panels possible in each chain depends on the number of DMX channels they use out of the 512 available in one DMX universe The EvenLED 1 x 1 m panel uses 96 channels in 16 bit mode This means that a maximum of five 1 x 1 m panels can be controlled independently in 16 bit mode in one DMX universe In 8 bit mode the 1 x 1 m panel uses 48 channels so ten 1 x 1 m panels can be controlled independently in 8 bit mode in one DMX universe The EvenLED 1 x 0 5 m panel uses 48 DMX channels in 16 bit mode and 24 channels in 8 bit mode Ten panel
11. panel and frame Figure 1 Panel mounts Panel locks 1 See Figure 1 Slide the panel mounts 11 into the panel mounting slits 8 2 Retract the panel locks 12 by pushing them towards the centre of the panel 3 Align the panel with the frame and release the panel locks 12 to lock the panel into the frame Mounting the EvenLED One frame mounting bar and two rigging clamps approved for the total weight to be suspended are required for each suspended vertical column of EvenLED panels To mount the EvenLED system 1 Check that the pipe or truss onto which you are mounting the EvenLED system is horizontal 2 See Figure 2 Loosen the clamp position locking rings 3 and slide the clamps 1 as wide apart as possible but making sure they will still match up with the supporting truss or other structure Figure 2 Mounting hardware 3 Lock the clamp position locking rings 3 to secure the clamps in position 4 Adjust the height of the frame mounting bar so that it can move freely by turning the height adjustment bolt 2 counter clockwise to lower the frame mounting bar clockwise to raise it 5 Loosen the frame mount locking knobs 4 and slide them towards centre of the frame mounting bar 6 to open the locks in the frame mount holes 5 8 EvenLED user manual 6 9 Adding panels vertically To add panels underneath the first panel 1 Insert the frame mount T hooks 7 in Figure 3 into the fram
12. 50 or 122 132 8 bit mode or reds 096 or O Ignore keep existing setting Reds 100 250 255 Show version and settings or reds 50 or 122 132 an version and or reds 0 or0 Ignore keep existing setting Reds 100 250 255 Calibrate or reds 50 or 122 132 Do not calibrate or reds 096 or0 Ignore keep existing setting Hold value for minimum 10 seconds while panels update Reds 20 46 56 Panels then show settings and The values for reds must be sent to red LEDs on channels 1 7 19 and 43 The values for greens and blues must be sent to green and blue LEDs on channels 3 5 9 11 45 and 47 Using back projection screens Table 2 Mode setting DMX sequence software version in an alternating sequence Installing a back projection screen in front of EvenLED panels gives a uniform panel of light The ideal distance between screen and EvenLED differs with screen design but is generally within 250 500 mm 10 20 inches A distance of approx 300 mm 12 inches often gives best results Using DMX Thief The Martin EvenLED DMX Thief available from Martin P N 90758096 is an accessory that gives the following options Complete control of DMX address setting in an EvenLED installation Grouping of LEDs so that they can be controlled in two or four horizontal or vertical strips four quadrants or one single group in which all LEDs behave identically Panel control Y axis inversion so that LEDs are n
13. EvenLED RGB LED Panel User Manual Dimensions All dimensions are in millimeters 1205 2009 Martin Professional A S Information subject to change without notice Martin Professional A S and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional A S or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional A S or its affiliates or subsidiaries P N 35000222 Rev C Safety Information WARNING Read the safety precautions in this section before installing powering operating or servicing this product The following symbols are used to identify important safety information on the product and in this manual A A A AA A DANGER Warning Warning Warning Warning Safety hazard Hazardous LED light Fire hazard Refer to user Risk of severe voltage Risk of emission Risk manual injury or death lethalorsevere of eye injury electric shock Warning Class 3B LED product Do not look at exposed LEDs from a distance of less than 40 cm 16 inches from the front surface of the product Do not view the light output with optical instruments or an
14. POWER IN socket is used to apply power to the EvenLED panel via a suitable cable with a blue PowerCon power input connector It accepts mains power at 100 240 VAC nominal 50 60 Hz The grey Neutrik PowerCon POWER THROUGH socket can be used to relay power to the POWER IN connector of another EvenLED panel via a suitable cable with a grey PowerCon output connector It supplies power at the same voltage and frequency as that applied to the POWER IN connector Warning Important safety precautions apply when using the POWER THROUGH socket see AC power on page 15 EvenLED user manual AC power Warning Electrical installation must be carried out by qualified professionals only Warning Read Safety Information on page 3 before attempting to install this product Isolate the entire installation from power and ensure that power cannot be reconnected accidentally before working on cables and connections Warning Connect EvenLED panels to AC power and to each other using the 20 A rated UL listed 12 AWG cables supplied by Martin as accessories for this product Replacement power cables from other sources can be used as an alternative but they must be 3 conductor SJT or better jacket type approved for a current of 20 A and temperature of 90 C 194 F minimum Replacement cables must also be minimum 12 AWG and UL listed in North America or have conductor size minimum 4 mm in other regions Warning See Figure 10 below When linki
15. VWTERTE EU safety EN 60598 1 EN 60598 2 17 IEC EN 60825 1 B EU EMG cits LETS RIe i EN 55015 EN 55103 1 EN 55103 2 5 US Loo oo ote enne EN 61000 3 2 EN 61000 3 3 Risen US safety norse cecer niere reri an rn die tra UL 1573 Canadian Safety e e CAN CSA E 60598 2 17 Included Items Panel Mounting frame 3 m UL listed 12 AWG SJT 20 A power input cable with PowerCon input connector P N 11541503 USC manual cate Tr P N 35000222 Accessories Neutrik PowerCon NAC3FCA power input connector cable mount blue P N 05342804 Neutrik PowerCon NAC3FCB power output connector cable mount light grey P N 05342805 1 4 m UL listed 12 AWG SJT 20 A daisy chain power cable with PowerCon connectors P N 11850099 2 25 m UL listed 12 AWG SJT 20 A daisy chain power cable with PowerCon connectors P N 11850100 3 25 m UL listed 12 AWG SJT 20 A daisy chain power cable with PowerCon connectors P N 11850101 Six unit flightcase for 6 x EvenLED 1 X1M 0 000 ccc eens P N 91515005 Related Items Martin RS 485 Opto Splitter optically isolated 4 way RS485 DMX splitter amplifier P N 90758060 Martin LightJockey 2 Windows Application incl Universal USB DMX Interface Box P N 90702055 Ordering Information EvenLED Hanging Bracket 1 m wide with width adjustable rigging clamps P N 90602000 EvenLED DMX Thief Addressing Configuration Tool llle e
16. anels distribute power on additional circuits each protected by its own RCD or use 3 phases on circuits protected by 3 phase RCDs Connecting the system 15 Connecting to power 3 m 9 8 ft power input cables for the EvenLED can be ordered separately from your Martin supplier Cables have a Neutrik PowerCon power input connector installed on one end and are ready for either hard wiring or installation of a power plug on the other end Loose PowerCon connectors and daisy chain power cables with PowerCon connectors for relaying power from one panel to another can also be ordered from Martin see Accessories on page 27 All Martin cables for the EvenLED are EU color coded see Table 1 Wire color Wire color EU color code US color code Conductor Symbol Screw US brown black live L yellow or brass blue white neutral N silver yellow green green ground earth S green Table 1 Conductor identification If you choose not to use the EvenLED power cables available from Martin you must use power cable that is rated 20 A minimum and suitable for the installation environment SJT or better jacket type and rated to 90 C 194 F minimum In North America power cable must be UL listed minimum AWG 12 In other regions it must be minimum 4 mm conductor cross section To connect to a single phase 3 wire live neutral ground earth power system 1 Isolate all power distribution circuits from power and ensure that po
17. at all safety wires are attached exactly as shown in Figure 6 and described above Adding panels horizontally To add a panel beside a panel that is already installed 1 Suspend the additional panel as described under Adding panels vertically on page 9 2 See Figure 7 Rotate the side to side locking latch 13 into place to fasten panels together The side to side locking latch 13 in Figure 7 is not designed to support weight All panels installed beside existing panels must be suspended as described under Mounting the EvenLED on page 8 and Adding panels vertically on page 9 EvenLED user manual Figure 6 Additional safety wire a A Figure 7 Side to side locking Planning the DMX control system EvenLED panels can be controlled using any standard DMX 512 control device via a DMX link This section explains the control options available and how to plan the DMX link accordingly Grouped and independent panel control In the following explanations we will assume that all the EvenLED panels in an installation are 1 x 1 m and set to 16 bit mode in which each of the 16 LEDs in a panel is controlled using 6 DMX channels This means that each panel uses 16 x 6 96 DMX channels EvenLED panels will only respond to commands they receive on DMX channel 1 and the channels immediately above it For the purposes of this explanation this means that a panel will respond to commands it receives on
18. between the mounting frame and panel for protection during shipment Keep these items if you intend to pack the product again in its original packaging material Using for the first time Before applying power to the panel Carefully review Safety Information on page 3 Check that your local AC mains power voltage is within the range listed on the panel s serial number label Install the panel as described in this manual 6 EvenLED user manual Physical installation Warning Read Safety Information on page 3 before installing the EvenLED Warning The safety and suitability of lifting equipment installation location anchoring method mounting hardware and electrical installation is the responsibility of the installer All applicable safety regulations and legal requirements must be observed when installing and connecting the EvenLED Installation must be carried out by qualified professionals only Contact your Martin supplier for assistance if you have any questions about how to install this product safely Location and orientation Warning The EvenLED must be securely anchored to a suitable supporting structure such as a truss Do not mount stand or stack on a surface Suspend in a vertical column only Do not install at any angle from the vertical Ensure that all rigging equipment and the supporting structure can bear ten times the weight of all installed devices Do not hang more than ten EvenLED panels in a vertical
19. ch Power is applied to the EvenLED as soon as it is connected to power Warning Maximum 9 panels in chain connected to AC mains power at 100 120 V A maximum 16 panels in chain connected to AC mains power at 200 240 V Mains power allow min 20 A per chain Figure 10 Interconnecting panels See Figure 10 for a diagram of power cable layout If you require help in planning or dimensioning the power distribution system please contact your Martin supplier for assistance Each EvenLED panel leaks a maximum total current of 1 mA to ground earth Panels must be correctly connected to ground so that this leakage current can be absorbed You must also allow for the leakage current when supplying panels with power from a circuit that has an RCD residual current device for ground fault protection as is normally required for safety reasons If you supply too many panels with power via one RCD the panels combined earth leakage may cause the RCD to trip RCDs are normally rated at their maximum trip current 0 50 so an RCD rated 30 mA can therefore trip when leakage to ground is as low as 15 mA If you have created a chain of 16 interconnected panels at 200 240 V and the 30 mA RCD trips you may have a particularly sensitive RCD and simply replacing it with another RCD with the same rating may solve the problem If replacing the RCD does not help or if the installation contains more than 16 p
20. e and the longest possible component lifetimes However LEDs are subject to wear and tear over the life of the product resulting in gradual changes in color and overall brightness over many thousands of hours of use The extent of wear and tear depends heavily on operating conditions and environment so it is impossible to specify precisely whether and to what extent LED performance will be affected However you may eventually need to ask Martin Professional to replace LEDs if their characteristics are affected by wear and tear after an extended period of use and if you require panels to perform within very precise optical and color parameters Cleaning Regular cleaning is essential for product life and performance Buildup of dust and dirt degrades the panel s light output and cooling ability Cleaning schedules will vary greatly depending on the operating environment It is therefore impossible to specify precise cleaning intervals for the EvenLED Inspect panels within their first few weeks of operation to see whether cleaning is necessary Check again at frequent intervals This procedure will allow you to assess cleaning requirements in your particular situation If in doubt consult your Martin dealer about a suitable maintenance schedule Warning Disconnect from power before cleaning Do not allow the product to become wet Take care not to damage wiring Important Do not use abrasives solvents or caustic cleaning products for cleaning
21. e lock holes 5 in Figure 2 Slide the frame mount locking knobs 4 in Figure 2 fully out from the center towards the ends of the hanging bracket and tighten them Make sure that they are locked as shown in Figure 5 on page 9 The frame is now secure See Figure 4 Attach one end of a safety wire around the truss pipe and the other end through the top handle 14 of the frame Connect DMX and power cables See Figure 3 on page 9 Loosen the panel to panel locking knob 9 and slide it to your right to open the latches in the panel to panel mounting holes 10 Insert the frame mount T hooks 7 in Figure 3 of the second panel into the frame mounting holes 5 in Figure 2 of the first panel Figure 4 Safety wire attachment See Figure 5 Slide the panel to panel locking knob 9 in Figure 3 fully to the left and tighten it The panel is now secure Figure 5 Securing frame lock knobs Physical installation Warning Warning 10 4 See Figure 6 Attach one end of the safety wire through both the top handle 14 in Figure 3 on the first frame and the already mounted safety wire Attach the other end of the safety wire through the top handle 14 in Figure 3 of the second frame to secure it below the first frame Do not suspend more than 10 panels in a vertical chain 5 If desired continue suspending panels beneath each other following the instructions given in points 1 to 4 above Check th
22. eC as 23 Service and MaintenanCE lele lel lel elle ke sn 24 CLS ANG A ea een n pa A e ka nn n bk hee ye ag ie gan Bataan see 24 Software installation ucl er eo RO 24 TrOUDIESNOOING mr 25 A ee et O hited ok 26 Introduction Thank you for selecting the EvenLED an LED based color changing panel luminaire from Martin Professional This product features Proprietary 6 W LEDs RGB red green blue color mixing DMX 512 control Auto sensing power supply unit with 100 240 VAC nominal 50 60 Hz operating range Product interlocking in vertical suspended columns Even illumination of back projection screens or other diffusers using fine 16 bit or 8 bit control RGB color mixing Various options for grouped LED control For the latest software updates documentation product specifications and other information about this and all Martin Professional products please visit the Martin website at http www martin com Comments or suggestions regarding this document may be e mailed to service martin dk or posted to Service Department Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Denmark Unpacking The EvenLED is supplied with this user manual This manual is also available for download from the Martin website at www martin com As soon as you remove the product from its packaging remove the foam inserts from the corners of the product and remove the cardboard strips that are wedged
23. elS seeoe 96 per independently controlled 1 x 1 m panel 48 in 8 bit mode Control resol tion cmo ng dee x etat nmt Ron x CH RUP E 16 bit RGB control of each LED PLOT bw VW EID USITT DMX512 1990 Photometric Data Light SOURCE s 229 Es UAR RER EIU AURI ES NE IPS Proprietary 6 W RGB LED array Resol tion orie panel 225i eiue ede ehe en a ek Sneed dr dr aet xe E 4 x 4 pixels Pixel pitch LED center to center distance llle 250 mm 9 8 in Pixels perm nenene a wee crure Aue loce a dire ime ete Ee dc LE E 16 Color resolution iio a eter en icm icm eR ee RR eee 16 bits per color Viewing angles Lic ee het a iy seen le er eni cobb E ee ees 112 56 56 Minimum LED source lifetime to 70 of initial outputlevel 40 000 hours at full intensity Construction Panels pack ee eck a eres RR a ESSE NENNEN Ud dE Gin ee Aluminum o WEE White Protection ratingi ie eR A GU EORR A cold aed Ges Ses see Ln aces IP20 Installation Orientations c eco con edet Rel wah cd eet n dada Vertical Mounting Suspended using mounting rail and clamps only max 10 panels per suspended column Connections Power IN OUT zu riui ues Xs RACE REIR EX Ra hace RUE A Re dee Neutrik PowerCon DMX data niscx ev taken ra Phe It pee Lebe we wer a aka toe 5 pin locking XLR DMX data QUito sh 2 ia eee a A usq ie ma Ken eoe 5 pin locking XLR DMX data through o ucc ea oes pene p e ER DEOR E DECOR dard AUS EUR ad 5 pin locking
24. er on can be disabled by sending a sequence of DMX values from a DMX controller see Configuring panels using a DMX controller on page 21 DMX control The EvenLED can be controlled using a standard DMX 512 controller 16 and 8 bit DMX control modes The EvenLED panel is designed to be used with 16 bit control per color This ensure smooth and step free operation and requires 96 DMX channels For applications where absolute smooth and step free operation is not required and or control channel capacity is limited EvenLED panels can be set to 8 bit control mode In 8 bit mode panels only use 48 channels DMX channel requirements in 16 bit and 8 bit modes The 1 x 1 m EvenLED panel contains 16 individually controllable RGB LEDs 16 LEDs x 6 DMX channels in 16 bit mode 96 DMX channels required by a 1 x 1 m panel in 16 bit mode 16 LEDs x 3 DMX channels in 8 bit mode 48 DMX channels required by a 1 x 1 m panel in 8 bit mode LED map By default the individual LEDs in the EvenLED are mapped for DMX control as shown in Figure 12 seen from the front light output side of the panel Depending on whether the panel is set to 8 bit or 16 bit control each LED is controlled using 3 or 6 DMX channels For example in 16 bit mode LED 1 at the bottom left of the panel is controlled on DMX channels 1 6 LED 2 is controlled on DMX channels 7 12 and so on Each LED is controlled as shown in DMX protocols on page 20
25. ex and is therefore not covered in detail in this manual If you need to add a different type of lighting fixture to a link with EvenLED panels it is easiest to add it at the end of the link using the last EvenLED panel s DMX OUT connector The fixture must be set to DMX address 001 and the controller must send commands to the fixture at the next available address after the DMX channels used by the last panel on the link EvenLED user manual System layouts Figure 8 gives examples of how systems can be laid out depending on the type of control required Note the different results of connecting to DMX THROUGH or to DMX OUT Panels are set to 16 bit mode in all the examples A Individual control Panels respond to different commands sent to different DMX addresses and can be controlled independently Max 512 DMX channels per chain using DMX OUT DMX IN DMX address 001 DMX address 097 DMX address 193 DMX address 289 DMX address 385 B Grouped control one group Panels have same DMX address and behave identically Max 32 panels per chain using DMX THROUGH before a splitter amplifier is required DMX IN DMX address 001 DMX address 001 DMX address 001 DMX address 001 DMX address 001 C Grouped conirol three groups 6 panels controlled in 3 pairs Pairs of panels with same DMX address behave identically Each pair has a different DMX address and can be controlled independently as a pair Max 512 DMX channels per chain using DMX
26. f AC mains power is 200 240 V 50 60 Hz Connect only EvenLED panels to POWER THROUGH sockets Do not connect any other type of device to these sockets PROTECTION FROM INJURY Do not look at exposed LEDs from a distance of less than 40 cm 16 inches from the front surface of the panel without suitable protective eyewear At less than this distance the LED emission can cause eye injury or irritation At distances of 40 cm 16 inches and above or if the LED output is diffused so that it is impossible to identify the individual LEDs the LED emission is harmless to the naked eye Do not look at LEDs with magnifiers or similar optical instruments that may concentrate the light output Ensure that all external covers components and installation fittings are securely fastened Install the EvenLED panel suspended vertically the correct way up from a truss or other supporting structure as described in this manual only Do not mount stand or stack on a surface Do not suspend more than ten EvenLED panels fastened to each other in a vertical chain Block access below the work area and work from a stable platform whenever installing servicing or moving an EvenLED panel Use two clamps installed as described in this manual to suspend the EvenL ED from rigging structures Do not use only one clamp Ensure that all supporting structures surfaces fasteners and lifting equipment can bear ten times the weight of all the devices they
27. he tens and the second row down shows the units ones in the version number The bottom two rows simply repeat the number displayed on the top two rows Figure 13 Software version display Software version display example See Figure 14 If a panel is running software version 29 80 40 20 10 10s 20 LED 15 lights in the top row o BEER 1 js 1 and 8 LEDs 9 and 12 light in the second row down eee 20 1 8 29 The bottom two rows repeat the number displayed on the top two rows Figure 14 Software version 29 20 EvenLED user manual Mode settings display See Figure 15 Mode settings are Show version shown on the first three LEDs from and mode Calibrate at 8 16 bit mode the left in row 1 and repeated on the Green T bit AL i MON first three LEDs from the left in row Red amp bit Green Yes a iP a 3 The other LEDs are not used Red No Mode settings display example For example if a panel is set to operate in 16 bit mode not display its software version at power on Sno verion m and mode alibrate at calibrate at power on pis ic settings at power on the LEDs will display the panel s Hed 8 bit poweren Green Yes mode settings as follows o neda Ng LEDs 13 the top left hand LED and 5 two rows down on the left will light green LEDs 14 and 6 will light red LEDs 15 and 7 will light gree
28. ink XLR to RJ 45 adapters will be required for connection to the EvenLED s 5 pin XLR DMX connectors RJ 45 cable connector pins are numbered from the left looking at the face of the connector with the locking clip on top see Figure 11 Connectors must be wired according to the 568 B system using the standard RJ 45 pin out for DMX applications Pin 1 White orange DMX data hot Pin 2 Orange DMX data cold Connecting the system 17 18 Pins 7 White brown and 8 Brown Common Pins 3 and 6 are available for Data 2 connections in DMX 512 A or similar systems They must be wired as follows Pin 3 White green Available for Data 2 hot Pin 6 Green Available for Data 2 cold Pin 1 Pin 8 Pins 4 and 5 are not used in currently available lighting control systems but can be wired as follows Figure 11 RJ 45 cable Pin 4 Blue connector pins Pin 5 White blue Making data connections Warning Disconnect the entire installation from power and ensure that power cannot be reapplied even accidentally before working on cables and connections See System layouts on page 13 for diagrams of possible installations To connect a panel to the data link 1 Connect the DMX data output from the controller to the EvenLED s DMX IN male XLR socket 2 Run the data link from the EvenLED s DMX OUT or DMX THROUGH female XLR socket to the data input of the next panel if you are not sure about the differe
29. ions Repair or replace damaged cables Trace and eliminate cause of interference Check for correct use of DMX OUT and DMX THROUGH connectors Check number of channels required by panels in one chain does not exceed 512 if individual control is required Incorrect mode setting Check panels are correctly set to 8 bit or 16 bit mode Panel defective Bypass panels on DMX link until the faulty device has been identified Have faulty panel tested and serviced by Martin service technician Other device on DMX link defective Panel is too hot Table 3 Troubleshooting Troubleshooting Bypass devices on DMX link until the faulty device has been identified Have faulty device tested and serviced by Martin service technician or device supplier Ensure free airflow around panel Clean panel Check that ambient temperature does not exceed maximum permitted level If problem persists contact Martin for service 25 Specifications 26 Physical Length He EHER EM at 995 mm 39 2 in Widths tis ea tee ai sheet aden ee RER pnt erates de 71 mm 2 8 in Height ashen rut Be He tui te pen des 1014 mm 39 9 in Weights eit pe nk o HR A CHER unas OA EE UE cado Rca dida 10 kg 22 0 Ibs Dynamic Effects Color Mixing ac ar Es ete Mut dh a des RGB Qr PEE Pe ee ee 0 100 GREN eie Lp stet bd Deren ren deeded adeeb eiie 0 100 D re EET 0 100 Control and Programming COMM o CENE LT DEED DMX DMX chann
30. ly Install the EvenLED in a vertical orientation the correct way up i e with the arrow on the back of the panel pointing up and the mounting T hooks at the top of the frame as shown on the cover of this user manual only Do not install horizontally or at any angle from the vertical Provide a minimum clearance of 5 cm 2 inches from adjacent surfaces and ensure unrestricted airflow around the air vents in the rear panel Do not illuminate surfaces less than 5 cm 2 inches from the front surface of the EvenLED Keep all combustible materials e g fabric wood paper at least 5 cm 2 inches away from the EvenLED Keep flammable materials well away from the EvenLED Do not operate the EvenLED if the ambient temperature Ta exceeds 40 C 104 F Do not modify the EvenLED in any way not described in this manual or install other than genuine Martin parts Do not stick filters masks or other materials directly onto LEDs Use only Martin approved accessories to mask or modify the light beam Do not attempt to bypass thermal or current overload protection systems or fuses Replace defective fuses with ones of the specified type and rating only If you relay power from one panel to another using POWER THROUGH sockets do not connect more than 9 panels in total to each other in an interconnected chain if AC mains power is 100 120 V 50 60 Hz Do not connect more than 16 panels in total to each other in an interconnected chain i
31. meet the same specifications as power input cables see details above EvenLED user manual gt pp Warning See Figure 10 on page 15 e When connecting to AC mains power at 100 120 V a maximum of 9 EvenLED panels in total may be interconnected in one chain that draws power via the first panel s power input cable e When connecting to AC mains power at 200 240 V a maximum of 16 EvenLED panels in total may be interconnected in one chain that draws power via the first panel s power input cable To relay power from one panel to another 1 Connect the grey PowerCon power output throughput connector on one end of the power relay cable to the grey PowerCon POWER THROUGH socket on the first panel 2 Connect the blue PowerCon power input connector on the other end of the power relay cable to the next panel s blue PowerCon POWER IN socket Continue connecting power relay cables from POWER THROUGH to POWER IN sockets When you reach the maximum permitted number of interconnected panels see Figure 9 on page 12 stop Do not connect any more panels to this chain If you need to connect more panels to power start a new chain connected to a separate power outlet Pe aa Current overload safety Warning The POWER THROUGH circuit is not protected against current overload Follow the safety precautions and instructions in this user manual carefully and do not overload this circuit EvenLED panels are protected by a current overload pro
32. n Figure 15 Mode settings display Configuring panels using a DMX controller The EvenLED can be set to the following modes by sending values from a DMX controller 8 or 16 bit control mode Software version and mode settings displayed at power on Calibration at power on Sequences of DMX values sent from the controller will set modes in all the EvenLED panels that are connected to the controller on the DMX link and interconnected using DMX THROUGH connectors Precise timing of the sequences is important so we recommend that you pre program a sequence that you can execute once panels are ready to receive mode setting values Pre programmed sequences that can be imported into the Martin LightJockey Windows PC application and sent to EvenLED panels are available free of charge from the EvenLED s Product Support page on the Martin website at www martin com Note that You must hold steps 1 and 9 constant while panels power on Step 1 and while you check panel mode settings Step 9 but steps 2 to 8 must change to the next step at 1 second intervals You only change DMX values for the red LEDs in each step The green and blue LEDs must be held at a value within the range 122 132 50 throughout the entire procedure The DMX values you send in each step must not contain fades the controller must snap immediately from one value to the next You must execute all the 9 steps in the sequence
33. nd before changing to the next step During steps 6 to 8 panels indicate which mode settings they are acquiring by lighting LEDs red or green as shown in Figure 15 on page 21 If you send an Ignore value for a mode setting that you do not want to change the LED concerned will light blue When the sequence reaches Step 9 panels will update their settings which takes a few seconds and then again display their software versions and their mode settings in an alternating sequence Check that the panels mode settings are correct with reference to Mode settings display on page 21 If you are satisfied with the settings cut power to the panels Stop sending the DMX values in Step 9 from the DMX controller Power panels on again They should now reset and be available for operation in the modes you have set them to EvenLED user manual Mode setting DMX sequence Function Panel configuration enable Start code 8 or 16 bit Show software version and mode settings at power on Calibrate at power on Repeat panel configuration enable values from Step 1 Step Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 value Hex value Setting Reds 20 46 56 Hold this value at power on Greensand ee als vag at power on and procedure Reds 40 97 107 Reds 60 148 158 Reds 80 199 209 Reds 20 46 56 Reds 100 250 255 16 bit mode or reds
34. ng POWER THROUGH to POWER IN connectors so that EvenLED panels draw power in a daisy chain from a single source Do not connect more than 9 panels in total to each other when supplying them with AC mains power at 100 120 V Do not connect more than 16 panels in total to each other when supplying them with AC mains power at 200 240 V If you do not respect these limits you will overload cables and components and create a serious safety hazard Each time you reach the maximum permitted number of interconnected panels in one daisy chain and want to supply more panels with power you must create a new daisy chain that draws power from a separate power outlet Warning For protection from dangerous electric shock the panel must be grounded earthed The AC mains power distribution system must be fitted with current overload and ground fault earth fault circuit breakers It must also provide a means to isolate panels from power and prevent accidental reconnection during service and each power distribution circuit must be dimensioned to safely handle a current of 20 A for each chain of EvenLED panels connected to it Important Do not connect the EvenLED to an electrical dimmer system even if the system is only used to supply 0 and 100 power as doing so can damage the EvenLED The EvenLED accepts AC power at 100 240 VAC nominal 50 60 Hz Do not connect to power at any other voltage or frequency There is no power on off swit
35. nt functions of these two sockets see Grouped and independent panel control on page 11 3 Terminate the data link by connecting a 120 Ohm 0 25 Watt resistor between the data 1 hot and cold conductors at the data output of the last fixture on the link If the link is branched i e split into separate links with an amplifier splitter terminate each branch of the link EvenLED user manual Operation Warning Class 3B LED product Do not look at exposed LEDs from a distance of less than 40 cm 16 inches from the front surface of the panel without suitable protective eyewear At less than this distance the LED emission can cause eye injury or irritation Do not look at LEDs with magnifiers or similar optical instruments that may concentrate the light output At distances of 40 cm 16 inches and above or if the LED output is diffused so that it is impossible to identify the individual LEDs the LED emission is harmless to the naked eye Powering on and startup When power is applied to an EvenLED panel by default it will first reset then automatically flash its software firmware version see Software version display on page 20 and mode settings see Mode settings display on page 21 twice each then start to calibrate the individual LEDs When calibration is complete it will flash all LEDs once The process normally takes less than one minute Software version mode settings display and automatic calibration at pow
36. plies with local building and electrical codes and has both overload and ground fault earth fault protection Connect EvenLED panels to AC power and to each other using the 20 amp rated UL listed 12 AWG cables supplied by Martin as accessories for this product Replacement power cables from other sources can be used as an alternative but they must be 3 conductor approved for a current of 20 A and temperature of 90 C 194 F minimum Replacement cables must also be minimum 12 AWG and UL listed in North America or have conductor size minimum 4 mm in other regions Cable jacket type must be SJT or better P D B Safety Information 3 Before using the EvenLED check that all power distribution equipment and cables are in perfect condition and are rated for the current requirements of all connected devices Isolate the EvenLED from power immediately if any cable cover or other component is damaged cracked wet or deformed Do not reapply power until all damaged items have been repaired by a qualified professional Do not expose the panel to rain or moisture Refer any service operation not described in this manual to an authorized Martin Service partner PROTECTION FROM BURNS AND FIRE The exterior of the EvenLED becomes hot up to 80 C 176 F during normal operation Avoid contact by persons and materials Allow the EvenLED to cool for at least 20 minutes before handling Install the EvenLED in a well ventilated area on
37. s can be controlled independently in 16 bit mode and twenty panels in 8 bit mode in one DMX universe Each time you reach the limit of 512 DMX channels you can add more independently controlled panels to the installation by adding a DMX universe For example using a PC with the Martin LightJockey 27M Windows application and Martin Universal USB DMX Interface Box package available from Martin P N 90702055 you can control two DMX universes With an additional Martin Universal USB DMX Interface Box P N 90702045 you can control 4 DMX universes Physical installation 11 12 Cable and link layout details EvenLED panels are controlled via the lighting industry standard DMX512 serial data protocol Installations must follow the standard recommended practices for DMX512 The key points to respect are Use DMX512 compliant cable Such cables have one or more twisted pairs with nominal characteristic impedance 120 ohms and low capacitance Single pair DMX512 cable is suitable for EvenLED panels because they do not use pins 4 and 5 of the DMX connection The minimum recommended wire size is 0 25 mm 24 AWG for runs up to 300 meters 1000 ft and 0 32 mm 22 AWG for runs up 500 meters 1640 ft Do not use microphone cable It does not have the correct characteristics and may cause erratic behavior of the system Shielded STP or unshielded UTP CAT 5 network cable can be used in fixed installations For further information see http
38. sses P N 90758096 EvenLED Software Uploader Tool 0 0 cee eee P N 90758097 EvenLED panel 1 xm i zelus eR da op he KORR en RR nn P N 90354500 Specifications subject to change without notice Specifications 27 Notes Disposing of this product Martin products are supplied in compliance with Directive 2002 96 EC of the European Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin products 28 EvenLED user manual y Martin www martin com e Olof Palmes All 18 e 8200 Aarhus N e Denmark Tel 45 8740 0000 e Fax 45 8740 0010
39. tection circuit in the internal PSU power supply unit that shuts down the panel if the panel s current draw exceeds safe limits If a panel shuts down although it is correctly connected to power this circuit may have been activated by a fault Disconnect the panel from power and contact your Martin supplier for assistance If the current overload protection circuit fails a 6 3 amp fast blow fuse in the PSU provides a final total protection This fuse is not user replaceable If you suspect that it has blown disconnect the panel from power and contact your Martin supplier for assistance Connecting the DMX control data link Connection pinouts XLR connections XLR connectors are suitable if DMX cable is used for the DMX link XLR pin numbers are normally identified with markings on connectors The 5 pin XLR connectors required to connect the DMX data cable to an EvenLED must be wired using the standard XLR DMX pin out Pin 1 Cable shield Pin 2 DMX Data 1 cold Pin 3 DMX Data 1 hot Pins 2 and 3 carry the DMX 512 signal Pins 4 and 5 are available for Data 2 connections in DMX 512 A or similar systems They must be wired as follows Pin 4 DMX Data 2 cold Pin 5 DMX Data 2 hot Do not connect the shield conductor to ground earth or allow it to come into contact with a connector shell as this may cause interference RJ 45 connections RJ 45 connectors are suitable if CAT 5 cable is used for the data l
40. umbered from the top of the panel 8 or 16 bit mode DMX output and input configurations See the user manual supplied with the DMX Thief and available for download from www martin com for full details Operation 23 Service and maintenance DANGER Read Safety Information on page 3 before carrying out service or maintenance work on the EvenLED Disconnect the panel from power before cleaning Important The EvenLED requires periodic cleaning to maintain reliable operation and protect the investment it represents Excessive dirt and particle buildup degrades performance causes overheating and may cause damage that is not covered by the product warranty The user will need to carry out periodic cleaning and it is also possible for the user to update the EvenLED software using the Martin EvenLED Software Uploader device All other service operations must be carried out by Martin Professional or its approved service agents Installation on site service and maintenance can be provided worldwide by the Martin Professional Global Service organization and its approved agents giving owners access to Martin s expertise and product knowledge in a partnership that will ensure the highest level of performance throughout the product s lifetime Please contact your Martin supplier for details It is Martin policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performanc
41. wer cannot be reapplied accidentally 2 Insert the PowerCon connector on a suitable power input cable into the EvenLED s POWER IN socket 3 Connect the conductors in the power cable to the power distribution circuit as follows Connect the yellow green wire to ground earth Connect the blue wire to neutral Connect the brown wire to live 4 Check that all installation work is completed and carry out appropriate tests and safety checks before applying power If using two phases of a three phase system to obtain 200 240 V between two phases follow the procedure given above but connect the blue wire to one phase and the brown wire to the other phase Power plug If you want to install a plug that is suitable for your AC mains power outlets on the power cable install a grounding type earthed plug with integral cord grip cable clamp that is rated 20 A minimum following the plug manufacturer s instructions Table 1 shows some possible pin conductor identification schemes If conductors are not clearly identified or if you have any doubts about proper installation consult a qualified electrician Relaying power between panels To ease installation and reduce the number of AC mains power input cables and outlets required power can be relayed from one EvenLED panel to another subject to the strict safety limits listed below Suitable cables for relaying power can be ordered from Martin Professional see Accessories on page 27 and must
42. www esta org tsp working_groups CP DMXoverCat5 htm Panels must be daisy chained i e the control data cable must be connected in one single chain of panels It is possible to split a link into two branches by using the DMX THROUGH and DMX OUT outputs from one panel at the same time but note that these outputs relay the DMX signal differently see Grouped and independent panel control on page 11 and see examples in Figure 8 Do not connect more than 32 devices in one chain on a DMX512 link without using a splitter amplifier Do not split a DMX link with a passive Y connector Branching the link with a Y will create multiple data reflections that can block or degrade signal transmission Use a dedicated DMX512 splitter amplifier such as the Martin RS 485 Opto Splitter P N 90758060 to extend the chain beyond 32 devices or split it into two or more branches Terminate each chain on the link with a 120 ohm resistor available from Martin P N 04150308 across the data hot and cold conductors pins 2 and 3 on a 5 pin XLR connector at the output of the last panel on the chain Avoid long parallel runs of AC power and control data cables as these may cause interference on the data link Mixing EvenLED panels and other types of fixture on a DMX link Mixing EvenLED panels and other types of lighting fixture on one DMX link is possible but if you add the lighting fixture in the middle of the link address setting is compl
43. y device that may concentrate the beam If the LED output is diffused by a back projection screen for example to the extent that it is impossible to identify individual LEDs the output is harmless to the naked eye This product is for professional use only It is not for household use This product presents risks of severe injury or death due to fire hazards electric shock and falls Read this manual before installing powering or servicing the EvenLED follow the safety precautions listed below and observe all warnings in this manual and printed on the EvenLED Install and operate the EvenLED only as described in this manual and in accordance with local laws and regulations Refer any operation not described in this manual to a qualified technician If you have questions about how to operate the EvenLED safely please contact your Martin dealer or call the Martin 24 hour service hotline on 45 8740 0000 or in the USA on 1 888 tech 180 PROTECTION FROM ELECTRIC SHOCK Connect the product to AC mains power within the range 100 240 V nominal at 50 or 60 Hz only Disconnect the entire installation from power and ensure that power cannot be reconnected accidentally before carrying out any installation or maintenance work Disconnect the product from power before removing or installing any cover or part and when not in use Ensure that the EvenLED is electrically connected to ground earth Use only a source of AC power that com