Home

ALM-008 `Pip Slope` - Operation Manual -

image

Contents

1. sec hold of the loop button will toggle the envelope curve from exponential to linear and vise versa The button release is then ignored loop mode wont toggle The loop mode and curve type are retained across power cycles ALM 8 Pip Slope Limited Warranty From the date of manufacture this device is guaranteed for a period of 2 years against any manufacturing or material defects Any such defects will be repaired or replaced at the discretion of ALM This does not apply to e Physical damage arising for mistreating i e dropping submerging etc e Damage caused by incorrect power connections e Overexposure to heat or direct sunlight e Damage caused by inappropriate or mis use Use of incorrect or non official firmware No responsibility is implied or accepted for harm to person or apparatus caused through operation of this product By using this product you agree to these terms ALM 8 Pip Slope Support For the latest news additional info downloads and firmware updates please visit the ALM website at http busycircuits com and follow busycircuits on twitter Please send any questions or comments to info busycircuits com ALM 8 Pip Slope
2. ALM 8 Pip Slope ALM OO8 Pip Slope Operation Manual MM InTroduclfion Technical Specifications mc Core Operdfion eege EEN 4 Gelee ter PH GerieralU ro Limited Wdrrdnfy_ SUPP OFF vr ALM 8 Pip Slope Introduction Pip Slope is an envelope generator It supports both Attack Decay and Attack Sustain Decay type functions with both direct and voltage control of Attack and Decay times Envelopes can be automatically looped and the function curve type changed between exponential and linear Feature list e Compact function generator in 4HP e Voltage control of attack and release times e Super snappy attack times sub Ims to 100s range e Optional self looping ability e Exponential and linear curves e State saved across power cycles e Reverse polarity protection e Skiff friendly Designed and Made in the UK Technical Specifications e Supply 12V e Current Draw 50ma e Size 4 HP Depth 32mm including power header ALM 8 Pip Slope Core Operation Panel Layout Pip slope YTig WGate Trigger input for e e Gate input for Attack Sustain Decay Attack Decay envelopes wy envelopes Knobs control attack and d
3. ecay times from sub Ims to 100secs vAttack s Inputs respond to 0 5v control voltage AN With cable patched associated knob then acts as attenuator on incoming control signal vDecay y Press loop button to enable disable automatic repeating of the envelope Loop A long 3 sec hold toggle the envelope shape between exponential and linear EE Out o 0 5v envelope output ALM 8 Pip Slope General Usage A trigger or gate signal is patched into the top inputs of the module as to produce an envelope between 0 and 5v at the output The red LED indicates the output level A trigger input will produce an envelope that rises to 5v and then instantly falls A gate input will rise and then stay high at 5v whilst the gate is high before falling Note the attack rising phase is always completed even if the gate finishes first The attack and decay times of the output envelope can be adjusted with the 2 relevant control knobs Fully CW gives times of approx 100 seconds whilst fully CCW gives approx sub 1ms times The times can be further controlled by control signals 0 5v response With a control signal patched the control knobs become attenuation controls on the input signal They are not offsets The loop button provides toggling of automatic triggering and repeating i e looping of the envelope The yellow LED indicates looping mode is enabled A long approx 3

Download Pdf Manuals

image

Related Search

Related Contents

  調査票 - IPA 独立行政法人 情報処理推進機構  暖らん  using Non-Oxidising Biocides and data logging  Manual do proprietário do produto  the manual - Workshop Supply  manuel d`entretien et d`utilisation MCH6  Pericolo - Tyrolit  User Manual - Nancy`s Knit Knacks  IC Intracom 503273  

Copyright © All rights reserved.
Failed to retrieve file