1. Ancillary Hook Wall Bracket Installation Dimensions B Use an electrical drill to make four holes for M6 screws on the above drawn positions and drive in the expansion M6 screws C Fix the installation board of the bracket firmly on the wall with four M6 screw nuts and washers D Push the power cable communication cable and video cable through the bracket tube then push the installing port on the top of the outer housing into the installing hole of the bracket tighten the 3 M6 screws and fix well Make sure the M6 screws just fit in the screw slot of the installing port of the housing See the picture below 212 Wall mount bracket screw t installing port E Put the power adaptor into the wall bracket and pin the power adaptor with the adaptor pinning board lest the power adaptor slides out See the figure below 13 Adaptor pinning board Attention The adaptor equiped can only be placed indoor or in water proof box or other water proof spaces it can not be placed directly outdoor otherwise water may seep in and damage the adaptor F Put up the wall bracket assembled with IR Low speed dome on the ancillary hooks Pull the power cable video cable and controlling cable out through the wire out going hole of the bracket then put the assembled on the two corresponding pegs on the installed peg board then push the bracket downward until it locks in place Make sure th
2. Enter number 1 and press the PREVIEW key 3 Invoke preset position 2 to configure the second tour position Enter number 2 and press the PREVIEW key 4 Invoke preset position 5 to configure the third tour position Enter number 5 and press the PREVIEW key 5 Invoke preset position 3 to configure the fourth tour position Enter number 3 and press the PREVIEW key 6 Invoke preset position 4 to configure the fifth tour position Enter number 4 and press the PREVIEW key 26 7 Invoke preset position 6 to configure the sixth tour position Enter number 6 and press the PREVIEW key 8 Invoke preset position 141 111 to finish tour configuration Enter number 141 111 and press the PREVIEW key 9 Invoke preset position 142 112 to start running the tour and the IR Low speed Dome Camera runs the tour and begins to cruise in the order of 1 2 5 3 4 6 If other devices are used to control the IR Low speed Dome Camera due to the protocol limitation some special functions of the IR Low speed Dome Camera may be not operational 7 4 Configure and start Left amp Right scan The IR Low speed Dome Camera has Left Right scan function The user can configure the left and right limiting positions for the required left amp right scanning area When running the left amp right scan the unit will scan forwards and backwards between the left and right limiting positions consecutively 7
3. 15 00001111 46 00101110 77 01001101 16 00010000 47 00101111 78 01001110 17 00010001 48 00110000 79 01001111 18 00010010 49 00110001 80 01010000 19 00010011 50 00110010 81 01010001 20 00010100 51 00110011 82 01010010 21 00010101 52 00110100 83 01010011 22 00010110 53 00110101 84 01010100 23 00010111 54 00110110 85 01010101 24 00011000 55 00110111 86 01010110 25 00011001 56 00111000 87 01010111 26 00011010 57 00111001 88 01011000 27 00011011 58 00111010 89 01011001 28 00011100 59 00111011 90 01011010 29 00011101 60 00111100 91 01011011 30 00011110 61 00111101 92 01011100 31 00011111 62 00111110 9 01011101 NO 87654321 NO 87654321 NO 87654321 94 01011110 125 01111101 156 10011100 95 01011111 126 01111110 157 10011101 96 01100000 127 01111111 158 10011110 97 01100001 128 10000000 159 10011111 98 01100010 129 10000001 160 10100000 99 01100011 130 10000010 161 10100001 100 01100100 131 10000011 162 10100010 101 01100101 132 10000100 163 10100011 102 01100110 133 10000101 164 10100100 103 01100111 134 10000110 165 10100101 104 01101000 135 10000111 166 10100110 105 01101001 136 10001000 167 10100111 106 01101010 137 10001001 168 10101000 107 01101011 138 10001010 169 10101001 108 01101100 139 10001011 170 10101010 109 01101101 140 10001100 171 10101011 110 01101110 141 10001101 172 10101100 111 01101111 142 1000
4. 20 7 5 Start 360 endless SCAN ak eights tb elt e tara Gr re re Be erdt t Gea 22 7 6 Stop Left amp Right scan and 360 scan 22 7 7 Configure Activate and Idle the Default Position 22 7 8 Open and close the menu of camera module sssssssseeeennennnne 22 VIII Table for the Functions of the IR Low speed Dome 25 VIV Trouble Shooting Table 26 Important Safeguards 1 During the course of transportation and storage the product should be avoided from incorrect operations such as heavy pressing strong vibration soaking etc which may cause damage to the unit 2 The product is designed for Wall mount and Pendant mount installation so it can not be installed upside down And the module should be handled properly so as not to bring about mechanical problems affecting the integrative functions of it 3 Do not let any foreign objects or liquid infiltrate into the unit which may damage the unit 4 Please follow all electrical standards for safety when the unit is being connected and please adopt the particular power supply which is provided with the unit The product s RS 485 and video signal adopt TVS class lightning damage preventing technology which can effectively prevent such pulse signal damage caused by lightning under 500W or electric surge RS 485 and video signal
5. 9600 BPS Remark If the IR Low speed Dome Camera is used at the farthest terminal there should be a parallel connection of a 120Q terminal matching resistor between A B lines of RS485 6 3 Configure Address Before actual operating of the unit the address of the IR Low speed dome camera should be configured The buttons from DIP 1 to DIP 8 of the 10 button Switch are used to set address of the IR Low speed Dome Camera from 1 to 255 The coding switches from DIP 1 to DIP 8 are equivalent to a 8 bit binary figure The state ON of each bit means 1 while OFF means 0 Corresponding state of coding switches and address is shown the table below Correspondence of Address and Coding Switch DIP1 DIP8 of the 10 button Switch NO 87654321 NO 87654321 NO 87654321 1 00000001 32 00100000 63 00111111 2 00000010 33 00100001 64 01000000 3 0000001 1 34 00100010 65 01000001 20 4 00000100 35 00100011 66 01000010 5 00000101 36 00100100 67 01000011 6 00000110 37 00100101 68 01000100 7 00000111 38 00100110 69 01000101 8 00001000 39 00100111 70 01000110 9 00001001 40 00101000 71 01000111 10 00001010 41 00101001 72 01001000 11 00001011 42 00101010 73 01001001 12 00001100 43 00101011 74 01001010 13 00001101 44 00101100 75 01001011 14 00001110 45 00101101 76 01001100
6. Installation and Connection of the device 5 1 Outer shape and Dimension The head for installation The house of the IR Low speed Dome camera The module of the IR Low speed Dome Camera 5 2 Preparation for the Installation 10 1 To avoid mistakes installation must be done by qualified personnel conforming to related regulations 2 Please check whether the attachments are all ready and whether the installing location and style of installation are compatible 3 The IR Low speed dome camera is composed of bracket housing module power adaptor installing screws etc 4 When the IR Low speed dome camera leaves factory it has undergone installation testing so the user can directly carry out the installation 5 Before installation please carefully read the instruction for installation in the User s Manual which is enclosed with the unit 5 3 Installation of Wall mount IR Low speed Dome Camera 5 3 1 Installation of Wall mount Bracket Attention The wall for the selected installation location must be firm without peeling To avoid quivering images resulting from unstable installation make sure the place for installation can sustain five times the total weight of the IR Low speed Dome Camera the bracket and the base A Use the bottom installation board of the bracket as template and draw the positions of the installing holes on the desired wall locus zx 4 07 57 Su
7. b Press PREVIEW key Then the IR Low speed Dome Camera will scan between the two positions 7 5 Start 360 endless scan The unit can carry out 360 scan function So that all direction scanning and monitoring effect is realized The user can operate on the keyboard the operation is as below a Input 136 b Press PREVIEW key 28 Then the unit will carry out 360 endless scan 7 6 Stop Left amp Right scan and 360 scan While the unit is carrying out Left amp Right or 360 scanning operation if you require the unit carry out other operations you can operate on the keyboard to stop the auto scan Operation is as below a Input 138 108 b Press PREVIEW key The Auto Scan can also be stopped by any operation on the joystick of the keyboard 7 7 Configure Activate and Idle the Default Position function The unit has default position function The user can configure default position for a key monitoring area according to actual conditions If not operated after 2 minutes the IR Low speed dome camera will automatically turn to the default position and monitor 1 Configure the Default Position Move the IR Low speed Dome Camera to a key monitoring area through controlling keyboard adjust the zooming ratio well then enter number 164 124 from the keyboard and press the PREVIEW key then the configuration is successful 2 Activate and idle the Default Position function The user can activate or idle the function of default pos
8. the unit into the installing hole of the bracket tighten the 3 M6 screws and fix well Make sure the M6 screws just fit in the screw slot of the installing port of the housing D Put the power adaptor into some installing box fix the adaptor well lest it slides out Attention The adaptor equiped can only be placed indoor or in water proof box or other water proof spaces it can not be placed directly outdoor otherwise water may seep in and damage the adaptor E Pull the power cable video cable and controlling cable out through the cable slot of the bracket leaving long enough cables for connection F Fix the bracket firmly on the ceiling with three M6 screw nuts and washers 16 Cable Slot 4000r200 _ 5 4 2 Connection of Exterior Cables Connect BNC video outlet of the IR Low speed Dome Camera with the already disposed video cable the power cable with the already disposed power cable DC15V and RS485 controlling cable with already disposed RS485 controlling cable The cables of IR Low speed dome camera is shown below Cable Application Connecting Objects Remarks DC15V IR Low speed dome Inner positive outer Power cable power supply power supply adaptor negative 485 cable 485 controlling IR Low speed dome Green A white B signal controlling device Video Cable video signal IR Low speed dome Inner X positive outer monitoring device negative Earth Conn
9. 1110 173 10101101 112 01110000 143 10001111 174 10101110 113 01110001 144 10010000 175 10101111 114 01110010 145 10010001 176 10110000 115 01110011 146 10010010 177 10110001 116 01110100 147 10010011 178 10110010 117 01110101 148 10010100 179 10110011 118 01110110 149 10010101 180 10110100 119 01110111 150 10010110 181 10110101 120 01111000 151 10010111 182 10110110 121 01111001 152 10011000 183 10110111 122 01111010 153 10011001 184 10111000 123 01111011 154 10011010 185 10111001 124 01111100 155 10011011 186 10111010 NO 87654321 NO 87654321 NO 87654321 187 10111011 210 11010010 233 11101001 188 10111100 211 11010011 234 11101010 189 10111101 212 11010100 235 11101011 190 10111110 213 11010101 236 11101100 191 10111111 214 11010110 237 11101101 22 192 11000000 215 11010111 238 11101110 193 11000001 216 11011000 239 11101111 194 11000010 217 11011001 240 11110000 195 11000011 218 11011010 241 11110001 196 11000100 219 11011011 242 11110010 197 11000101 220 11011100 243 11110011 198 11000110 221 11011101 244 11110100 199 11000111 222 11011110 245 11110101 200 11001000 223 11011111 246 11110110 201 11001001 224 11100000 247 11110111 202 11001010 225 11100001 248 11111000 203 11001011 226 11100010 249 11111001 204 11001100 227 11100011 250 11111010 205 11001101 228 11100100 251 11111011 206 11001110 229 11100101 252 11111100 207 11001111 230 11100110 253 111
10. 11101 208 11010000 231 11100111 254 11111110 209 11010001 232 11101000 255 11111111 If protocol address and Baud rate are configured when power is on then the IR Low speed dome camera must be switched off and restarted to make the configuration valid VII Basic functions of the IR Low speed Dome Camera 7 1 Power on and self examining of the unit Once power on the unit enters self checking procedure it moves pan 360 tilt 90 then moves to its original position then the lens zoom from far to near then from near to far Through the self check the unit checks 203 the mechanical moving performance of the pan tilt the electrical performance of the controlling system the controlling of the camera module After the IR Low speed Dome Camera finishes self check it stays at the original position and is ready to receive controlling instructions 7 2 Configure and Invoke Preset Positions The function of preset positions works in this way the IR Low speed Dome Camera saves the parameters of the current pan tilt angel and zooming ratio of the lens under a representing number quickly invoke those parameters when needed the unit will turn to the corresponding position and be adjusted to corresponding zooming ratio Users can use such devices as controlling keyboard to save and invoke preset positions quickly and conveniently The IR Low speed Dome Camera can support up to 64 preset positions 7 2 1 Confi
11. 4 1 Configure Left amp Right limiting positions The user can freely set a beginning point as the Left Limiting Position an end point as the Right Limiting Position Attention If the beginning point is the same as the end point the unit will scan 360 endlessly Meanwhile the unit will automatically record the zooming ratio of the lens at the beginning point and take this data as the constant zooming ratio of the lens when scanning also the unit will record the vertical angle of the beginning point and take this angle as the constant vertical angle when scanning The operation of configuring Left amp right limiting position is as below 1 Configure the Left Limiting Position Operate the joystick towards left 27 adjust the image to the desired postion then A Input 130 100 B Press PREVIEW key 2 Configure the Right Limiting Position After the Left Limiting position is configured well operate the joystick towards right adjust the image to the desired postion then A Input 131 101 B Press PREVIEW key After configuring well operate as below to run the scan 7 4 2 Start Left amp Right scan To start Left amp Right scan means that the user use an external order to start the scan and to make the unit scan between two limiting positions so that the user can monitor the corresponding district The user can operate on the keyboard the operation is as below Operation through invoking function code a Input 133 103
12. IR Low Speed Dome Camera User s Manual Please read the manual carefully before installing and using the unit Table of the Contents Introductions ii ore e S ctt le eu ee 3 Il Technical Data in det IRL ieee E ee ee Es 3 II Characteristics AANE EE E ERR Rr P RET rei 4 V Description of FUNCHONS 5 acierto ie retreat ice ced 4 V Installation and Connection of the Device 6 5 1 Outer shape and Dimension ese ee b ten ertet tede 8 5 2 Preparation for the Installation 9 5 3 Installation of Wall mount IR Low speed Dome 10 5 4 Installation of Pendant mount IR Low speed Dome 13 VI Configure the system of the IR Low speed Dome 13 6 1 Config re Protocol eh bes bietet nde 13 amp 2 Configure Baud Rae ee rim tec er E EDEN REPE SEP ERR 13 6 3 Config re Address ee ette AA S ee RE cedi 13 VII Basic functions of the IR Low speed Dome 17 7 1 Power on and self examining of the unit 17 7 2 Configure and invoke Preset Positions 19 7 3 CONIGUES and TUN Tour GroUp seven rete 20 7 4 Configure and start Left amp Right scan
13. ances the camera module can not carry out auto focus e When the object is not in the center of the view e When simultaneously observe a far object and a near one clarity for both of the images can not be guaranteed at the same time e When observing objects with extreme brightness such as neon lights spotlight etc e When the object is behind the glass with water drops or dust e When the object moves very fast e When the object is large sized and drab such as wall e When the object is too dark or fuzzy Iris Control e The system takes auto iris as the default The iris can automatically sense the change of the environmental light and make quick adjustment so that the brightness of the image is stable e The user can manually adjust the iris through controlling the keyboard to obtain desired brightness for the image 12 Automatic Back Light Compensation BLC Automatic Back Light Compensation can be realized via district dividing In extremely bright background the camera module can compensate the brightness of the relatively dark objects while adjust the light of the bright background avoiding that the whole image is too bright to watch due to the too high brightness of the background while the object is too dark to be distinguished so that the clear image can be got 9 13 Automatic White Balance According to the ambient brightness the camera module can automatically adjust the White Balance to re display the real color V
14. automatic tour function is a built in function of the IR Low speed dome camera According to actual requirement the user can arrange the preset positions into the automatic tour in the desired order then the user can use such equipment as controlling keyboard to make the IR Low speed dome camera automatically move as per the order of the preset positions set in the tour with stipulated time intervals e Automatic tour among preset positions can be realized through grouping together the preset positions into the tour e The tour order is programmable The staying time at each preset position can be configured e Sixteen preset positions can be stored in one tour Altogether 4 tours can be configured with the speed dome 7 Left amp Right Scan Left right limiting positions can be set through controlling keyboard and the IR Low speed Dome Camera can automatically scan horizontally between the left limiting position and the right limiting position at the pre set speed 8 360 Scan 360 Scan is available with the IR Low speed Dome Camera After adjusting the vertical angle and the zooming times well the user can run the 360 endless Scan through invoking easy command 9 Default Position Function Pa The unit supports default position function The user can configure default position for a key monitoring area according to actual conditions If not operated after 2 minutes the IR Low speed Dome Camera will automatically turn to the de
15. e IR Low speed dome camera is right the factory default is Pelco D for protocol 4800bps for baudrate 001 for address code You must make sure that the configuration of them must be identical to that of the 18 controlling device The corresponding switches for configuration is shown in the following figure OFT SX X iff M X p Address switches 1 8 jj VAS Spare switches 9 10 j j for other usage when j Y X the unit is upgraded ME l i N On fi MET 2 172345678910 12541 f j 6 t 1 i uy v Protocol switches 1 2 Baud Rate switches 3 4 X Amplified picture 6 1 Configure Protocol The DIP 1 and DIP 2 of the 4 button switch on the PCB board is for communication protocol configuration Please refer to the following table NO 2 1 PROTOCOL 1 0 0 PELCO D 2 0 1 PELCO P 3 10 JCO 4 1 1 PELCO D1 If the controlling device could only support the preset position numbers below 128 please use PELCO D1 controlling protocol 6 2 Configure Baud Rate DIP 3 and DIP 4 of the 4 button switch on the PCB board is used to 9 configure Baudrate of communication the default configuration is 4800BPS Following table shows states of coding switches and cosrresponding Baudrate No 43 Baudrate 1 00 1200 BPS 2 01 2400 BPS 3 10 4800 BPS 4 11
16. e wall bracket is well fixed with the installation board then direct the screw on the bracket to the corresponding hole on the lower part of the installation board and tighten the screw 5 3 2 Connection of Exterior Cables Connect BNC video outlet of the IR Low speed Dome Camera with the already disposed video cable the power cable with the already disposed power cable DC15V and RS485 controlling cable with already disposed RS485 controlling cable The cables of IR Low speed dome camera is shown below Cable Application Connecting Objects Remarks 14 DC15V IR Low speed dome Inner positive outer Power cable power supply power supply adaptor negative 485 cable 485 controlling IR Low speed dome Green A white B signal controlling device Video Cable video signal IR Low speed dome Inner positive outer monitoring device negative Earth Connecting the IR Low speed dome Black cable connecting earth for the earth port lightening proof When connecting make sure the polarity of RS485 controlling cable is correct A RS485 positive B RS485 negative If wrongly connected the IR Low speed Dome Camera will be out of control 5 3 3 Switch on Power a Make sure the polarity of plugs sockets and the connection of cables is correct then switch on power b The IR Low speed Dome Camera begins to do the self check it moves pan 360 tilt 90 then mov
17. ecting the IR Low speed dome Black cable connecting earth for the earth port lightening proof When connecting make sure the polarity of RS485 controlling cable is correct A RS485 positive B RS485 negative If wrongly connected the IR Low speed Dome Camera will be out of control 5 4 3 Switch on Power a Make sure the polarity of plugs sockets and the connection of cables is correct then switch on power b The IR Low speed Dome Camera begins to do the self check it moves pan 360 tilt 90 then moves to its original position then zooms in and zooms out once Through the self check the unit checks the mechanical moving performance of the pan tilt the electrical performance of the controlling system the controlling of the camera module After the IR Low speed Dome Camera finishes self check it stays at the original position and is ready to receive controlling instructions c Use controlling device to control the IR Low speed Dome Camera checking whether it can perform the functions of the pan tilt and the lens of the camera module If not please check the configuration of communication protocol Baud rate and address and the connection of 485 controlling cable VI Configure the system of the IR Low speed Dome Camera Before the installation of the IR Low speed Dome Camera you must confirm if the protocol the Baud rate of the controlling system and the address code of th
18. ed Dome Camera will automatically invoke the preset positions in the group one by one The dwelling time at each preset position can be set within 1 255 seconds Up to 16 preset positions can be saved in each tour group And at most 4 tour groups can be configured The operation is as below A In the keyboard initial state enter number 140 110 and press the PREVIEW key to enter the tour configuration 25 After entering the configuration add preset position number to the tour Enter the first desired preset position number and press the PREVIEW key and the first preset position is successfully added Then goes the second one Enter the second desired preset position number and press the PREVIEW key and the second preset position is successfully added More preset positions can be added in the same way C After all the required preset positions having been added in the tour enter the number 141 111 on the keyboard and press the PREVIEW key to exit the tour configuration D Start Running a Tour In the keyboard initial state enter number 142 112 and press the PREVIEW key to start running the preset tour Example Configure the tour order to be 12534 5686 please configure preset positions before tour configuration 1 Invoke preset position 140 110 to enter tour configuration Enter number 140 110 and press the PREVIEW key 2 Invoke preset position 1 to configure the first tour position
19. erfaces may differ in operation operation details are subject to the related manufacturer s manuals Under certain circumstances of special requirements and operations please refer to dealers for necessary information VIV Trouble Shooting Table Problems Possible causes Remedies No action no Wrong connection of power cables Correct picture no indicator Power supply adaptor damaged Replace on when power is Fuse damaged Replace Switched on Bad power cable connection Correct Address or Baud rate configuration Normal self check Configure again wrong and image but Protocol configuration wrong Configure again out of control RS485 bus bad connection Check RS485 bus connection Abnormal Mechanical failure Repair self check image Camera Module inclined Reinstall 2 39 with motor noise Unstable image Fuzzy image Some IR Low speed Dome Camera of control or control delayed Power supply not enough Bad connection of video cable Power supply not enough At Manual focus state Vitreous cover dirty Power supply not enough Whether matching resistor is in the IR Low speed Dome Camera at the farthest end The distance is too far the attenuation of the signal on RS485 is too much The driving power of the 485 converter is not enough 33 Replace better to place the adaptor nearby the IR Low speed Dome Camera Correct Replace Operate the IR Low speed Dome Camera or
20. es to its original position then zooms in and zooms out once Through the self check the unit checks the mechanical moving performance of the pan tilt the electrical performance of the controlling system the controlling of the camera module After the IR Low speed Dome Camera finishes self check it stays at the original position and is ready to receive controlling instructions c Use controlling device to control the IR Low speed Dome Camera checking whether it can perform the functions of the pan tilt and the lens of the camera module If not please check the configuration of communication protocol Baud rate and address and the connection of 485 controlling cable 15 5 4 Installation of Pendant mount IR Low speed Dome Camera 5 4 1 Installation of Pendant mount Bracket Remarks The ceiling for the selected installation location must be firm without peeling To avoid quivering images resulting from unstable installation make sure the place for installation can sustain five times the total weight of the IR Low speed Dome Camera the bracket and the base A Use the bracket as template and draw the positions of the installing holes on the desired ceiling locus B Use an electric drill to make three holes for M6 screws on the above drawn positions and drive in the special M6 screws C Push the power cable communication cable and video cable through the bracket tube then push the installing port on the top of the outer housing of
21. fault position and monitor 10 Power off Operation resuming function If the unit is carrying out Preset Position Default Position Left amp Right Scan Tour 360 Scan etc functions when the power is off then when the power is on the unit will resume carrying out the functions after it finishes the self examining 11 Control the lens of the Camera Module Focal Length Control Users can adjust the Focal length through controlling the keyboard to get panoramic view or close view that they desire Focus Control The system takes auto focus as the default While moving the camera module can automatically focus on the center of the object view to get clear image Under special circumstances the user can manually adjust the focus to achieve desired image effect e Manual focus can be realized through controlling the keyboard or matrix For details please refer to the operation manual of the controlling keyboard or matrix e In the state of manual focus the user can control focal length to make the lens focus on the object If the IR Low speed Dome Camera is configured to automatically resume auto focus upon joystick operation when there is operating on the joystick the IR Low speed Dome Camera will automatically focus If a period of time is configured for auto focus resuming once there is 8 no controlling order received after the period of time the IR Low speed Dome Camera will resume auto focus Under the following circumst
22. ginning and end position can be set freely 4 groups 16 Preset Positions for each dwelling time at each preset position can be set Vertical Angle can be set freely LED Array 2 Groups Visible distance reaches 100m Triggered by photosensitive resistor Default triggered by camera module IR Lamp turned on when camera module turns to Black amp White mode IP66 6 1Kg II Characteristics Latest LED Array technology adopted for IR lamps LED Array has higher brightness longer visible distance over 100m more evenly distributed light field and much longer lifespan In built module programme can automatically identify 5 brands of camera modules including LG SONY HITACHI CNB KPC Adopting multi functional high performance DSP design with stable performance Integrated design with compact structure and high reliability Precise electric motor driver ensuring smooth running and agile reaction The internally saved data will not lose within a short period of time 1 4 year since power off 64 preset positions for random storage and accurate locating 4tour groups 16 preset positions can be included in each tour group Support Left amp Right scan and 360 scan function Support Default Position function Support round the clock 24hours per day monitoring at night the unit automatically converts to Black amp White mode and the IR lamp automatically turns on Power off operation resum
23. gure Preset Positions After turning the IR Low speed Dome Camera to desired position and adjusting to desired zooming ratio through the keyboard enter the number that is to represent the preset position press the PRESET key Now you have configured one preset position Example Configure preset position No 1 a Use the joystick to move the IR Low speed Dome Camera to the desired position and adjust the lens of the camera module well b Enter 1 c Press the PRESET key Manual focus approach can be adopted to configure preset positions for 24 distant objects that is after adusting the lens to focus on distant place control the keys FOCUS and FOCUS on the controlling keyboard to configure optimal focal image storage to avoid fuzzy images resulting from the interference of other distant objects 7 2 2 Invoke Preset Positions The function enables the IR Low speed Dome Camera to quickly return to the preset position Enter the number 1 64 key for preset position number which you need to invoke the LED displays the preset position number Then press the PREVIEW key The IR Low speed Dome Camera will return to the preset position e g Invoke the No 1 preset position a Enter 1 b Press PREVIEW key 7 3 Configure and run tour groups The tour group function is to group some preset positions together if the user wants to invoke these preset positions with only one external order the IR Low spe
24. ing function Automatic Iris Focus and White Balance IV Description of Functions 1 IR Lamp 1 The latest LED Array technology is adopted for this IR Low speed Dome Camera LED Array is highly integration of traditional LED Comparing with traditional LED it has some advantages as below A Higher brightness Since LED Array is integration of LED the brightness and the viewing distance are greatly increased the visible distance for this unit is up to 100m or so B Longer lifespan due to the difference of the transparent material and the heat dispersion effect the life span of the LED Array is about 10 times as the traditional LED and the attenuation is far less than traditional LED C More evenly distributed light The half intensified beam angle of the traditional LED is about 10 well it is 10 120 variable angle for LED Array which together with multi angle disposal make the light evenly distributed and can light the whole room without Flashlight effect T 2 There two groups of IR lamps users can set the triggering factor of the IR lamps as Photosensitive Resitance or the Day night Conversion of the camera module 2 Trace the Target The users can control the movement of the pan tilt by operating the joystick of the keyboard so that they can trace the moving object or change the monitoring area The angle of view or the size of the image of the object can be changed through adjusting the focal le
25. invoke any preset positions Clean the vitreous cover Replace better to place the adaptor nearby the unit Install matching resistor in the IR Low speed Dome Camera Replace the controlling cable with thicker one Replace with converter that has separate power supply
26. ition through the keyboard Enter number 162 122 and press the PREVIEW key the function is activated Enter number 163 123 and press the PREVIEW key the function is idled 29 7 8 Open and close the menu of camera module The unit has a function as configuring the parameters of the Camera Module Users can open and close the menu of the camera module by invoking 145 and 146 preset positions After entering the menu users can configure the camera module conveniently The operation is as below 1 Open the menu of the camera module Input 145 95 Press PREVIEW key b 2 Close the menu of the camera module w Input 146 96 b Press PREVIEW key Attention If the camera module doesn t have menu function this function with the unit is unavailable VIII Table for the functions of the IR Low speed dome camera Notice PELCO D and PELCO P protocols have no corresponding orders for part of the special functions so we converted functions of some of the commonly used orders generally converting in the way of invoking preset position configuring preset position Order converting correspondence is shown in the following table Invoke Invoke preset preset Keyboard operation meaning Keyboard operation meaning position position No No 30 Configure left limiting position Configure right limiting position Start Left amp right sca
27. ngth In the default Auto focus Auto Iris state following the movement of the pan tilt the lens will quickly adjust itself to get clear image according to the change of the object 3 Automatic Adjustment of Focal Length Movement Speed When the focus is long and the unit is in under manual operation due to the high sensitivity of the IR Low speed Dome Camera even the slightest movement of the joystick would make the image move quickly which causes image losses Based on human design the unit can automatically adjust the horizontal and vertical moving speed of the pan tilt according to the current focal length which makes the manual target tracing operation much easier 4 Color B amp W auto conversion Designed for round the clock 24hours a day monitoring In the daytime the image is color well at night it automatically turns to Black amp White at the same time the IR Lamp is turned on 5 Configure and Invoke Preset Positions The preset position function works in this way the IR Low speed Dome Camera saves the parameters of the current pan tilt angel and zooming ratio of the lens under a representing number quickly invoke those parameters when needed the unit will turn to the corresponding position and be adjusted 6 to corresponding zooming ratio The user can quickly and conveniently invoke the preset position with the controlling keyboard The IR Low speed Dome Camera supports 64 preset positions 6 Automatic Tours The
28. nning Start Pan tilt 360 scanning Stop Pan tilt auto scanning 162 i 163 Start tour configuration 163 Exit tour configuration Start running a tour 142 IR lamps to be triggered by photosensitive resistor IR lamps to be triggered by camera module Enter menu of the camera Module Exit menu of the camera Module Activate default position function Idle default position function Configure default position function If preset position numbers larger than 128 could not be invoked on the controlling device please choose PELCO D1 protocol functions operation table as below Invoke Invoke preset preset Keyboard operation meaning position position No No Configure left limiting position Configure right X limiting position Start Left amp right scanning Start Pan tilt 360 scanning Bis 106 Keyboard operation meaning IR lamps to be triggered by photosensitive resistor IR lamps to be triggered by camera module Enter menu of the camera Module Exit menu of the camera Module 108 Stop Pan tilt auto scanning 122 Activate default position function 110 Start tour configuration 123 Idle default position function 111 Exit tour configuration 124 Configure default position function Intelligent control and all of the functions of the unit can be realized through the keyboard s control over the IR Low speed Dome Camera Since different controlling system int
29. should be kept enough distance from high voltage equipments and cables when they are in transmission and necessary steps should be taken to prevent lightning damage or power surge 5 No matter the unit is runing or not the camera module should never be aimed at the sun or other object with extremely bright light Otherwise the camera module s CCD might be permanently damaged 6 There are no parts inside the unit which can be repaired by the users themselves When mechanical problems arise do not be in a haste to do any repairing please refer to the User s Manual to find the trouble If causes can not be located please refer servicing to qualified professionals All servicing must be done by authorized personnel Introduction Adopting latest technological achievements cutting edge manufacturing techniques the IR Low speed Dome Camera is created with many years of accumulated experience Equiped with a high performance DSP camera module with zooming lens integrating built in Pan tilt and digital decoder it represents the future trend of hi tech monitoring products The unit is capable of freely positioning consecutively tracing and scanning which realizes real all directional monitoring The unit can automatically adapt to ambient brightness and object distance Its digital control and elegantly simple design maximally reduces the connection between differnent parts in the system which improves the reliability of the sys
30. tem and facilitate the installation and maintenance Driven by a stepper electric motar the unit runs smoothly reacts quickly and locates positions accurately At the same time the unit has multiple intelligent functions such as Preset Position Tour Left amp right scan 360 scan Default Position etc The IR lamp of the IR Low speed Dome Camera adopts the latest LED Array technology LED Array features higher brightness longer visible distance more evenly distributed light field much longer lifespan and very little attenuation with which the night vision effect is greatly improved With varieties of high performances the IR Low speed Dome Camera can be applied in every walk of life to monitor moving objects in large areas such as monitoring smart buildings bank city streets power system airports bus railway stations etc Il Technical Data DC15V 4A Adapter should be within 2 meters to the Power Supply unit Working Temperature 30 C 60 C Relative Humidity Power Consumption Communication Protocol Communication System Communication Bardrate Address range Horizental Moving Speed Vertical Moving Speed Movement range Preset Positions Left amp Right Scan Tour Group 360 Scan IR Lamp IR Lamp Triggering Protecting Grade Weight 0 90 30W PELCO_D PELCO_P PELCO_D1 RS485 bus cable 1200 2400 4800 9600bps 001 255 6 14 S 6 14 S Pan 360 endless Tilt 0 90 64 Be