1. 48 22 562 3030 e vidicon vidicon pl CROW ELECTRONIC ENGINEERING LTD BS 1 SIREN High Power Siren With Battery Back up and Flashlight P N 7101439 Rev E Y A YS A Y INSTALLATION INSTRUCTIONS amp USER MANUAL Siren BS 1 Manual Installation BS 1 Features The BS 1 siren is a new generation of professional high power acoustic siren with battery back up and flashlight which include all performance and reliability for security alarm system Features Outdoor battery back up siren with flashlight Double housing External 3mm plastic PC with UV Internal 0 8mm metal Continuous frequency modulated sound Tamper protection in 3 ways Screw or Cover opening or tearing housing from the wall Positive and negative alarm trigger inputs Trigger input to activate only the flashlight Siren period can set as follow trigger or 3 min cutoff Selector for lamp or xenon Alarm by main power failure Protecting against totally battery discharge Plug Terminal for easy Installation Environmental immunity Functional Description Alarm Trigger The alarm can be triggered by applying high or low voltage to the GO or GO inputs terminals respectively The sound and flashlight triggered together Alarm siren duration depended on the Trigger selector state E F T Follow Trigger TMR siren cutoff after 3 minutes this state is recommended in order to avoid violation of any loca
2. CROW ELECTRONIC ENGINEERING LTD Crow WARRANTY POLICY CERTIFICATE This Warranty Certificate is given in favor of the purchaser hereunde the Purchaser purchasing the products directly from Crow or f its authorized distributor Crow warrants these products to be free from defects in material and workmanship under normal use and service for a period of 24 months from the last day of the week and year whose numbers are printed on the printed circuit board inside these products here the Warranty Period Subject to the provisions of this Warranty Certificate during the Warranty Period Crow undertakes at its sole discretion and subj to Crow s procedures as such procedures are form time to time repair or replace free of charge for materials and or labor products proved to be defective in materials or workmanship under normal and service Repaired products shall be warranted for the remain of the original Warranty Period All transportation costs and in transit risk of loss or damage r directly or indirectly to products returned to Crow for repair or replacement shall be borne solely by the Purchaser Crow s warranty under this Warranty Certificate does not cover products that is defective or shall become defective due to alteration of the products or any part thereof by anyone other Crow b accident abuse negligence or improper maintenance failure caused by a product which Crow did not provide d fail caused by so
3. ftware or hardware which Crow did not provide e u or storage other than in accordance with Crowis specified operat and storage instructions There are no warranties expressed or implied of merchantabilit fitness of the products for a particular purpose or otherwise w extend beyond the description on the face hereof This limited Warranty Certificate is the Purchaser s sole and exclusive remedy against Crow and Crow s sole and exclusive liability towa the Purchaser in connection with the products including without limitation for defects or malfunctions of the products This Warranty Certificate replaces all other warranties and liabilities wheth written non mandatory statutory contractual in tort or otherwise In no case shall Crow be liable to anyone for any consequential incidental damages inclusive of loss of profit and whether occ by negligence of the Crow or any third party on its behalf for of this or any other warranty expressed or implied or upon any other basis of liability whatsoever Crow does not represent that these products can not be compromised or circumvented that these prod will prevent any person injury or property loss or damage by bur robbery fire or otherwise or that these products will in all cases provide adequate warning or protection Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary fire robbery or other events occurring without pro
4. inal Block Connection Terminal 1 Marked FL Trigger for the flashlight Connect it to an output in the Alarm System Active while the input is low Terminals 2 Marked GO Trigger for the siren and the flashlight Active while the input is high Terminals 3 Marked GO Trigger for the siren and the flashlight Active while the input is low Terminal 4 Marked GND Connect to ground of the control unit Terminal 5 Marked 12V Connect to a positive Voltage output of 13 6 14 2Vdc source usually from the alarm control unit Terminals 6 amp 7 Marked TAMPER If a Tamper function is required connect these Terminals to a 24 hour normally closed protective zone in the control unit If the front cover of the siren is opened or siren box is tearing from the wall an immediate alarm signal will be sent to the control unit Important Cut off the power before you make the connections 7 Plug the terminal to the drive board 8 Power on the system and check that it function properly 9 Connect the Back up battery Important Keep attention to the polarity of the Battery a reverse polarity can cause damage to the driver circuit 10 Mount the metal cover by 2 screws 11 Close the housing by 1 screw Siren BS 1 Specification Sound Pressure Level 128dB Current consumption Speaker and Strobe Standby 8mA Alarm 1600mA 13 8V DC Trigger Level Trigger Low Max 1Vdc Mm E Sire
5. l regulations Flash Trigger The flashlight can be triggered by applying low level to FL terminal Flash duration is not limited and the time of flashlight is set by control panel as long as trigger available the flashlight will be active Tamper The tamper is normally closed while the housing is closed with the screw so in this state the tamper terminals are shorted 0 Ohm The tamper will open while opening the screw or by tearing the housing from the wall Note It s essential to screw the tamper socket to the wall properly Power Failure On Power Failure the siren and flashlight are triggering until power supply is restored or time out period 5 minutes expires Battery Protection The Siren is supplied with protection against totally battery discharge by cutting off the siren when voltage level falls down to less then 8Vdc Installation Instructions 1 Choose the mounting location for the siren the wall must be even and free of holes and excessive protrusions 2 Mark and drill 5 holes with the help of the attach drill pattern plate 4holes for the housing base and 1 for the tamper Note Take a consideration about the wires inputs in the housing base 3 Open the siren housing 1 screw on the front fig 1 and remove the metal cover 2 screws fig2 4 Unplug the terminal 5 on the siren driver 5 Mount the siren housing on the wall 6 Connect the wires to the terminals 5 Term
6. n Alarm Period F T Follow trigger Input Impedance Alarm Flash Trigger 1K Ohm Tamper Switch N C 28 Vdc Maximum current 0 1 A open when ere emo Material External Box ABS 3mm thick Internal Cover Metal 0 8 mm thick Weight Without Battery 1 85 Kg Operating temperature range 300C to 60 C Case Protection Level Water splash resistant Plastic PC with UV protection Conformal coated circuit board LATE 7 Siren Includes 1 Horn 4 Tamper 2 Lamp 5 Terminal Block 3 Battery 6 Connector YAdNVL Acl GN9S 09 09 d TA A A A A I SYIIR 3 COM TMP CONTROL PANEL 12V OUT
7. viding an alarm but it is insurance or a guarantee that such will not occur or that there no personal injury or property loss or damage as a result Consequently Crow shall have no liability for any personal injury property damage or any other loss based on claim that these prod failed to give any warning If Crow is held liable whether directly or indirectly for any loss or damage with regards to these products regardless of cause or or Crowis maximum liability shall not in any case exceed the purcha price of these products which shall be the complete and exclusi remedy against Crow Mow ELECTRONIC ENGINEERING LTD ISRAEL 12 Kineret St Airport City 70100 Israel Tel 972 3 9726000 Fax 972 3 9726001 e support crow co il w www thecrowgroup com USA 2160 North Central Road Fort Lee NJ 07024 USA Tel 12019440005 Fax 12019441199 support crowelec com w www crowelec com AUSTRALIA 429 Nepean Hwy Brighton East VIC 3187 Australia Tel 61 3 9596 7222 Fax 61 3 9596 0888 e crow crowaust com au w www crowaust com au LATIN AMERICA 5753 N W 151st Street Miami Lakes FL33014 USA Tel 1 305 823 8700 Fax 1 305 823 8711 e sales crowlatinamerica com w www crowlatinamerica com ITALY VIA Giulianello 4 14 00178 ROMA ITALY Tel 39 0676 12912 Fax 39 0676 12601 e info deatronic com POLAND VIDICON SP ZO O 15 Povazkowska St 01 797 Warsaw Poland Tel 48 22 562 3000 Fax