1.  with bows instead of elbows        If there is a danger that the pressure pipe gets completely  blocked  e g  by a ball valve  a bypass has to be installed  in the pressure pipe  so that always a minimal flow of water  trough the pump is guaranteed        For more information  see on the net at www royal exclusiv de  Simply enter the part number or name into  the search box or email to  info royal exclusiv de   All information without guarantee  We try our best  but printing errors reserved     Klaus Jansen    Richard Byrd Str  7    50829 Cologne    Germany    Fon  49 0 221 222886 0    Fax  49 0 221 22288622  info royal exclusiv de    www royal exclusiv de    5 3  Electrical connection     setting up operation  Check whether voltage and frequency on the type label of  the pump match the supply voltage  The person respon   sible for the installation has to check whether a standard  conform grounding is available     It is necessary to check if the electrical installation has a  highly sensitive earth leakage circuit breaker  ELCB GFCI   is available  30mMA     DIN VDE 0100T739      The fuse for the electrical net has to be one level high then  the fuse of the pump     6  Maintenance and cleaning  Disconnect the pump from the power supply prior to each  maintenance work     Red Dragon supply  and flow pumps are essentially to  be classified as low maintenance  Usually the necessary  maintenance work is limited to a check of the impellor for  obstruction     Remove obstacles fr
2. Klaus Jansen    Richard Byrd Str  7    50829 Cologne    Germany       Fon  49 0 221 222886 0    Fax  49 0 221 22288622 ince 1986  info royal exclusiv de    www royal exclusiv de KKKKK    Operating  and maintenance manual Red Dragon 1 pump  For all Red Dragon pumps with or without AKB  anti lime bypass        Klaus Jansen    Richard Byrd Str 7    50829 Cologne    Germany    Fon  49 0 221 222886 0    Fax  49 0 221 22288622  info royal exclusiv de    www royal exclusiv de       Operating  and maintenance manual Red Dragon 1 pump  For all Red Dragon pumps with or without AKB  anti lime bypass     1  Foreword   2  Use of the pump   3  Fields of application   4  Installation Fitting   5  Bringing into service of the pump  5 1  Inlet Pipe  intake side   5 2  Pressure Pipe  pressure side   5 3  Electrical connection     setting up    ORONMNN ao    1  Foreword   This manual is indented to inform you correctly and ex   haustively  i e  also over potential risks caused by the  pump  The user  fitter and maintenance technician is res   ponsible to check the compliance with the procedures and  advises in this manual  The Red Dragon 7 are built with  state of the art technology and to comply with existing sa   fety regulations  Nevertheless this device may cause risks  for individuals and for property  if it is used improperly or  not regarding to its designated use  or if safety advises are  ignored    If the pump is used improperly  the liability of the manufac   turer and the operating 
3. TURER     Only use wiring  installations  adapters  extension cables  and connection cables with grounding typ plugs  which are  approved for outdoor usage  DIN VDE 0620  with suffici   ent cable diameter  Do not pull on the wiring of the device  and to not use the wiring to carry the device  If the wiring  is damaged or broken the device may no longer be used   Reparation is not possible as the wiring is permanently  grouted in the engine housing  Take care that the pow   er plug never falls into water or gets wet  If the plug gets  wet in any kind  it has to be opened by a professional and  cleaned by purging with demineralised water  Protect the  plug and the wiring against heat  oil  UV light and sharp  corners  The manufacturer is not liable in any way for any  damages  which are made by improper installation or by    the carelessness of the user or installer     In general  when put out of service  the pump has to be  cleaned extremely thoroughly  Before it newly brought into  service the ease of movement of the impeller has to be  checked by hand  If the impeller cannot be moved round  by hand  the pump needs to be disassembled and cleaned  completely  It is forbidden to disconnect the plug from the  controller   pump while the device is in use  This can result  in serious damages to the electronic components and to  dangerous situations due to grounding problems  The con   troller may exclusively be connected and operated on an  ELBC protected wiring  30 mA rating  an
4. applications with  clean water  Clean water in this case is defined as wa   ter not containing solid particles  which could damage the  bearings  Examples for particles or pollutants not suitable  are sand or pyrolosite after a manganese peroxide treat   ment in a pond  Damages caused by such pollutants in the  water do not fall under warranty or service     The most common use case for the Red Dragon 1 pumps  are in the context of filtration systems  aquariums  ponds or  swimming pools  and or to supply a beck creek or waterfall   The pump is not self supplying and therefore can be used  above the water surface and only in combination with a  backpressure valve on the inlet pipe  In this case the pump  has to be filled with water befor it is set into operation      2 to  40  C   0   C to max   50   C  2 bar  20m head of water     Temperature of the liquid   Environment temperature   Max  working pressure     4  Installation Fitting   Caution    Before you install the pump you have to read the manual  thoroughly  Damages  which are caused because the ma   nual was not read thoroughly  do not fall under warranty     When unpacking the pump  check whether all parts were  delivered completely and undamaged  Detected damages  have to be reported within 8 days after the purchase of the  pump at your retail location  When unpacking the pump  it  is possible that the inside of the pump is wet  The pump is  tested before it leaves the factory    Prior to its packaging the pump is tre
5. ated with a biodegra   dable disinfectant in order to neutralize possibly present  bacteria  The pump therefore has to be purged with water  thoroughly before usage    Please check the pump for damages before you set it into  operation  Should the pump have damages it may not be set  into operation  Please inform your retailer immediately if the  pump is set into operation even though it is damaged  any  warranty and liability is void        Pince 1956    Kk kkk    Pull the plug electrical socket and make sure that the pump  cannot be switch on  During the course of the installation  the pump may not be connected to the power supply  To  avoid injuries take care to not reach into opening of the  pump with your hands or fingers  when the pump is con   nected to the power supply     5  Bringing into service of the pump   Never use the device without water throughput  The  pump will automatically start when the power connection  is established     The pump may be used in almost any position  However  it hast so stand stable on a solid base  The inlet pipe is  connected to the suction side of the pump  see figure 1         It has to be assured that the pump can be de aerated  trough the outlet  2   The pump should ideally be placed  beneath the water level  3      For more information  see on the net at www royal exclusiv de  Simply enter the part number or name into  the search box or email to  info royal exclusiv de   All information without guarantee  We try our best  but prin
6. d into a grounding  receptacle    The wiring may not be modified or replaced  Electrical in   stallations on garden ponds always have to be compliant  and according to national and international directives and  requirements  Never open the case of the device or of the  appending parts if this is not explicitly suggested in the  user manual  Never apply technical modifications the de   vice  Only use original spare parts and accessories  Let  only authorized customer service facilities conduct repa   rations  Never use the pump with other liquids than water     For more information  see on the net at www royal exclusiv de  Simply enter the part number or name into  the search box or email to  info royal exclusiv de   All information without guarantee  We try our best  but printing errors reserved     Klaus Jansen    Richard Byrd Str 7    50829 Cologne    Germany    Fon  49 0 221 222886 0    Fax  49 0 221 22288622  info royal exclusiv de    www royal exclusiv de    If you have any questions or problems consult an electrici   an  your dealer or the manufacturer Royal Exclusiv     3  Fields of application   Die Red Dragon 1 pump is suitable for freshwater  brack   water  saltwater and to pump other non aggressive  non   explosive liquids that do not contain oil  It can haul clean  as well as     to a certain extent     polluted water  The pump  is not suitable for water with larger particles  The pollu   tants may not exceed 0 8mm in size    In general the pump is to be used for 
7. etic phosphoric acid or common deliming agents for  water purification appliances like coffee makers  The con   tainment shell of the motor must also be delimed  Coarse   greasy plaques must be removed under ordinary tap water  prior to deliming using a mediumcoarse brush  Please ob   serve the relevant safety regulation attached to every sa   les package prior to using deliming acids  Wear protective  clothing and goggles        The rear bearing bush requires spezial attention as most  errors are made here     If the rear bearing brush  fig  6  sits on the shaft when re   moving the impeller unit  it is vital to carefully remove the  bearing from the shaft  fig  7      If the bearing is mounted into the appropriate notch  the O   ring must be firmly pressed into the notch using a medium   size slotted screwdriver  fig  8      Impeller units where the bearing is firmly bonded to the  shaft must under no circumstance be reinserted into the  pump  Blocked bearings may cause damage to the pump  or prevent it starting up  due to the O ring grinding against  the bearing seat     And now we wish you much pleasure of her pump  a regu   lar maintenance guarantees you a long term        Royal Exclusiv in July 2012       For more information  see on the net at www royal exclusiv de  Simply enter the part number or name into  the search box or email to  info royal exclusiv de   All information without guarantee  We try our best  but printing errors reserved     
8. hermore  major  impurities may generate vibrations     We recommend therefore already after three months  the  Red Dragon pump to check  to determine the possible  maintenance intervals that  can be depending on precipi   tation between 2 12 months     Unplug or disconnect the power plug and remove the pump  from the silicone hose by gently rotating it  Or solve screw  connection  Remove the four titanium pump head srews  and check the impeller for snail shells  mussels  active car   bon pellets  filter cotton or residual food   fig  1  In case of  larger accumulations  please clean the pin whel  Pull out  the impeller   fig  2  clean and delime the entire pump              soe hS    For assembly  fig  3 5   fix the O ring in position  then ca   refully let the magnetic impeller with the lip on top click into  place  Caution   Strong magnetic forces          For more information  see on the net at www royal exclusiv de  Simply enter the part number or name into  the search box or email to  info royal exclusiv de   All information without guarantee  We try our best  but printing errors reserved     Klaus Jansen    Richard Byrd Str 7    50829 Cologne    Germany    Fon  49 0 221 222886 0    Fax  49 0 221 22288622  info royal exclusiv de    www royal exclusiv de       6 1 Deliming and cleaning the impeller   Now delime the impeller unit using a suitable deliming  bath  Never use hydrochloric acid   not even diluted   This may damage the pump  Suitable substances are  for   mic ac
9. om the impellor with a slim and spiky  tool  A decreasing supply rate is often the result of dirt   Possible calcinations  especially in saltwater applications   has to be removed with a very soft acid as for instance  vinegar  Avoid applying pressure to the sides of the im   pellor or the rotor  The pump can be disassembled nearly  completely for cleaning     In freshwater  and saltwater applications calcification only  appears in very hard water and after a complete re filling  of the pond  After this the largest amount of carbonate will  be omitted within 2 3 days     All Red Dragon pumps feature an integrated automatic  switch off function  The energy input is continuously measu   red electronically  If power consumption increases for whate   ver reasons  e g  in case of calcification resulting in sluggish    g               Pince 1956    Kk kkk    bearings     the electronic system of the pump recognizes this  as a failure and the pump is switched off automatically    By plugging unplugging the power plug the pump can be  made ready for operation again  Please note that it is pro   hibited to circumvent the electronics to make the pump run  again by constantly plugging unplugging the power  If the  Red Dragon pump switches off  there is always a problem  which must be remedied  This is usually a cleaning interval  that is to be implemented  Continuous circumventing of of  the pump electronics may result in motor damage which is  not covered by guarantee or goodwill  Furt
10. permit are void  For safety reasons  children and juveniles younger than 16 years as well as  people who do not recognize possible risks or who are not  familiar with this manual may not use the device  Please  preserve this manual carefully  In the case of a disposal  please hand over the complete manual     Please keep up this user   s manual carefully   On change of ownership pass the complete user guide     The combination of water and electricity can be a serious  threat to life and limb  when not installed according to di   rections or when used improperly     2  Use of the pump   Only use the device when no body parts have contact to the  water  Before you reach into the water always disconnect the  pump from the power supply  Compare the electrical speci   fication on the type label of the device with the specification  of the power supply  Make sure that the device is connected  to an ELCB  earth leakage circuit breaker  with an assigned  leakage rating of max  30 mA  DIN VDE 0100T739   Only  operate the device on a correctly installed power plug     Keep the power plug and the wiring dry  Install the wiring  protected in order to avoid damages     Pince 1986  Kk kkk  6  Maintenance and cleaning ou    seeeceeeeceeeeeeeeeeeeeeeeeeeees 5  6 1 Deliming and cleaning the impeller    6    Never use the device    without water throughput       IT IS NOT ALLOWD TO CUT THE WIRING OR THE PO   WER PLUG  DOING SO WILL IMMIDEIATLY VOID ALL    WARRANTY AND LIABILITY OF THE MANUFAC
11. ting errors reserved     Klaus Jansen    Richard Byrd Str  7    50829 Cologne    Germany    Fon  49 0 221 222886 0    Fax  49 0 221 22288622  info royal exclusiv de    www royal exclusiv de    The pump can be placed submersed  4  or out of the wa   ter  dry   5   In the case of a dry placement  adequate air  ventilation has to be assured  Furthermore the pump may  not be exposed to direct sunlight  Place the pump as close  as possible to the actual water connection  hence the inlet  piping has to be as short as possible        If the pump is placed above the water level  6  the ins   tallation of a backpressure valve  7  is mandatory  In this  case the inlet piping of the pump has to be filled with water  before the pump is set to operation  In such a setup the risk  of the pump to run dry is very high  when the backpressure  valve does not work properly  Damages which are caused  by the pump running dry are excluded from warranty           Pince 1956    Kk kkk    5 1  Inlet Pipe  intake side    If no sufficient amount of water reaches the pump because  the drag of the inlet pip is to strong  the pump will consume  a lot of power and the electronics gets very warm in the long  run  The electronic contains a self protection mechanism for  this case and will lower the power  If the pump delivers less  and less water after hours or days of operation it is possible  that the inlet piping is too large     The best thing is to enlarge the diameter of the piping on  the inlet side b
12. y 1     2 sizes directly in front of the pump  in  order to maximize the delivery rate and to minimize energy  consumption     Any coupling has to be 100  air proof  If a tube is used as  inlet  this has to fulfil the requirements of a suction pipe     It is very important  that the initial inlet at the pump is  straight   Minimum distance of 5x the diameter of the inlet  pipes from the housing to the first bow   In this way the  efficiency factor is maximized  because the water enters  laminary at the impeller     Always use bows instead of elbows        For more information  see on the net at www royal exclusiv de  Simply enter the part number or name into  the search box or email to  info royal exclusiv de   All information without guarantee  We try our best  but printing errors reserved     Klaus Jansen    Richard Byrd Str  7    50829 Cologne    Germany       Fon  49 0 221 222886 0    Fax  49 0 221 22288622 Since 1986  info royal exclusiv de    www royal exclusiv de KKKKK    If the inlet piping is longer than 10 m or the suction head is 5 2  Pressure Pipe  Pump outlet  pressure side    higher than 1 m the inlet piping has to be 1 or 2 sizes larges The pressure pipe has to have the same diameter as the  than the intake of the pump  intake of the pump in order to minimize pressure loss  high  flow rates and noise  The best thing is if you enlarge the  pressure pipe directly after the pump oulet  in order to ma   ximize the pump capacity and to safe energy        Always work
    