1.    Instruction Manual    Dear Customer     If you follow the recommendations con   tained in this Instruction Manual  your  appliance will give you constant high  performance and will remain efficient  for many years to come     CONTENTS    RECOMMENDATIONS AND SUGGESTIONS       CHARACTERISTICS       INSTALLATION       USE       MAINTENANCE    o IN  Oo IA I         RECOMMENDATIONS AND SUGGESTIONS    INSTALLATION       e The manufacturer will not be held liable for any damages resulting  from incorrect or improper installation    e The minimum safety distance between the cooker top and the   extractor hood is 650 mm    Check that the mains voltage corresponds to that indicated on the   rating plate fixed to the inside of the hood    e For Class 1   appliances  check that the domestic power supply  guarantees adequate earthing    Connect the extractor to the exhaust flue through a pipe of mini   mum diameter 120 mm  The route of the flue must be as short as  possible    e Do not connect the extractor hood to exhaust ducts carrying com   bustion fumes  boilers  fireplaces  etc      e Ifthe extractor is used in conjunction with non electrical applian   ces  e g  gas burning appliances   a sufficient degree of aeration  must be guaranteed in the room in order to prevent the backflow  of exhaust gas  The kitchen must have an opening communicating  directly with the open air in order to guarantee the entry of clean  air     USE          e The extractor hood has been designed exclusiv
2. LM V  L Light Switches the lighting system on and off  M _ Motor Switches the extractor motor on and off  Vv Speed Sets the operating speed of the extractor     1 Low speed  used for a continuous and silent air change in the presence of    light cooking vapour        2 Medium speed  suitable for most operating conditions given the optimum    treated air flow noise level ratio        3 Maximum speed  used for eliminating the highest cooking vapour emission     including long periods       MAINTENANCE       Grease filters       CLEANING METAL SELF SUPPORTING GREASE FILTERS    e The filters must be cleaned every two  months of operation  or more frequently  with heavy usage  and can be washed in  a dishwasher    e Remove the filters one at a time  after  disconnecting the relative fastening  elements    e Wash the filters  taking care not to bend  them  Allow them to dry before refit   ting    e When refitting the filters  make sure that  the handle is visible on the outside        Odour filters  Recirculation version        REPLACING ACTIVATED CHARCOAL FILTERS    e These filters are not washable and can   not be regenerated  and must be repla   ced approximately every four months of  operation  or more frequently with heavy  usage    e Remove the grease filters    e Remove the saturated activated carbon  filters by releasing the fixing hooks    e Fit the new filters by hooking them into  their seating   e Replace the grease filters           LIGHT REPLACEMENT    40 W incandesce
3. ely for domestic  use to eliminate kitchen smells    e Never use the hood for purposes other than for which it has ben  designed    e Never leave high naked flames under the hood when it is in ope    ration    Adjust the flame intensity to direct it onto the bottom of the pan   only  making sure that it does not engulf the sides    Deep fat fryers must be continuously monitored during use  ove    rheated oil can burst into flames      The hood should not be used by children or persons not instructed  in its correct use     MAINTENANCE          e Switch off or unplug the appliance from the mains supply before  carrying out any maintenance work    e Clean and or replace the Filters after the specified time period    e Clean the hood using a damp cloth and a neutral liquid deter   gent           CHARACTERISTICS       Dimensions          Hood Type 52 70             L1 522 702  Components  Ref  Q ty Product Components  9 1 1 Hood Body  complete with  Controls  Light   E Filters       9 4 Reducer Flange    150 120 mm                         Q ty Documentation  1 Instruction Manual          INSTALLATION       Drilling the Support surface and Fitting the Hood       Make a rectangular opening on the base of  the hanging unit  leaving a minimum of 13  mm from the outer edges        Hood Type 52 70  L1 497 677          SNAP ON FITTING   For hoods with snap on side supports only  set up for a support panel thickness of between 15   mm and 30 mm    e Insert the hood until the side support
4. nt light   e Remove the metal grease filters  or open  the filter retaining grill   e Unscrews the bulbs and replace them with  new ones having the same characteristi   cs    e Replace the metal grease filters  or close  the filter retaining grill        Ce    Dir  89 336 CEE  73 23 CEE  93 68 CEE    The symbol E on the product or on its packaging indicates that this product may not be treated as household waste  Instead it shall be  handed over to the applicable collection point for the recycling of electrical and electronic equipment  By ensuring this product is disposed of  correctly  you will help prevent potential negative consequences for the environment and human health  which could otherwise be caused  by inappropriate waste handling of this product  For more detailed information about recycling of this product  please contact your local city  office  your household waste disposal service or the shop where you purchased the product     436003033_01   051212    
5. s  snap into place    e Lock in position by tightening the  screws Vf from underneath the  hood              SCREW FITTING    For hoods without snap on side supports only    e Fix the hood to the hanging unit using  the screws 12f  3 5x16 self threading   provided           Connections    DUCTED VERSION AIR EXHAUST SYSTEM    When installing the ducted version  connect the hood to the chimney using either a flexible or rigid  pipe    120 or 150 mm  the choice of which is left to the installer        e To install a y 120 mm air exhaust con   nection insert the reducer flange 9 on the  hood body outlet    e Fix the pipe in position using sufficient  pipe clamps  not supplied     e Remove any activated charcoal filters        RECIRCULATION VERSION AIR OUTLET    e Cuta hole    120 mm in the wall unit over  the hood    e Insert the reducer flange 9 on the hood  body outlet    e Connect the hood body outlet to the  top part of the wall unit using a rigid or  flexible pipe    120 mm  to be selected by  the installer    e Fix the pipe in position using sufficient  pipe clamps  not supplied     e Ensure that the activated charcoal filters  have been inserted        ELECTRICAL CONNECTION    e Connect the hood to the mains through a two pole switch having a contact gap of at least 3  mm    e When opening the sliding carriage for the first time after installing the hood  pull it out briskly  until it clicks     USE       Control Panel              ra eu    123    W D U                    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
F7 Drive User Manual  AQUALAND GRAPH Ver.2  BRX 250/500  エンドウモザイク病に関する調査  Lire le communiqué  I133 - Ficha técnica Enlucido de acabado y de fondo para productos    Sandusky CSC6625PU Instructions / Assembly  Lirio by Philips Suspension light 57037/48/LI  Télécharger le Côte-d`Or Magazine de septembre version pdf    Copyright © All rights reserved. 