1. P DURIP ARIK 8 DURIPARK Mini CO AND NO TOXIC GAS DETECTION CONTROL PANEL SURAN Installation and user manual electronica I3 DU mI ARIK DURAN JE Electr n nica 9 2014 DURAN ELECTRONICA S L All rights reserved www duranelectronica com Certificate n FS82426 I m an D U RPAR K v02 LIST OF COMPATIBLE PRODUCTS DURPARK mini control panel 1 MODULE DURPARK 1 ZONE Module line LINE 3 WIRE DURPARK CO detector 3 WIRE DURPARK NO detector REPLACEM ENTS Module line 3 7A power source for DURPARK control panel 1 6A power source for DURPARK mini control panel Power control module DURIPARK INDEX page INTRODUCTION an EEG EUCH PR EU ac n dE Eas 4 PREVIOUS CONSIDERATIONS rara criar ran n n CO CCS 5 OPTICAL INDICATIONS CREER riada Ed Era 6 PROGRAMMING DETECTOR 7 DETECTOR NUMBERING DEPENDING ON NUMBER OF 5 7 FACTORY DEFAULT CONFIGURATION FOR THE VARIOUS STANDARDS AND RELAY OUTPUTS 8 DISPLAY INFORMATION WITH A DISCONNECTED MODULE LINE 8 KEYPAD FUNCTIONS WITH A DISCONNECTED 8 LANGUAGE CHANGE oom at EYE a 9 ie onan ees ered or dU do dos 9 SYSTEM PROGRAM MING ENGINEER MODE MODULE LINE 9 DURPARK NO DETECTOR CALIBRA
2. TO 16 Always start numbering each group with detector number marked as Remember that each group s parameters can be independent each group being able to detect the same or different gases The number of groups is related to the number of ventilation speeds or relay outputs required by each standard Thus for example Portuguese standard requires the relay outputs to act on double speed ventilators therefore two relays being necessary so its configuration will be fixed to one single group per module line If you program two groups one for CO and another for NO and you do not have available or do not require independent ventilators to engage the pertinent r la y outputs must be connected in parallel Spanish Standard with 2 groups see connection example in page 22 The module which is above the power source is in charge of its management and control In case of it malfunctioning control of the power source battery and eh Will stop working the fault optical indicator will illuminate and the following message will Show eese Even in this mode the module lines will keep functioning with all its functions operational I manDURPARK vO2 1 6 DEFAULT SETTING CONFIGURATION FOR THE VARIOUS STANDARDS AND RELAY OUTPUTS Standard Ventilation Ventilation Entry delay Output Alarm Group Nr Relay ON OFF delay level Gases outputs Portuguese 1st Speed 15 Speed lm 2m Vent1 only 1 group 50ppm lt 50ppm 200ppm 1 1 gas per Relayl
3. elec rved www dura 9 2014 DURAN ELECTRONICA S L All rights rese 22 28 WARRANTY DURAN ELECTRONICA S L guarantees that the DURPARK Control Unit has been manufactured subject to strict quality controls DURPARK and its variants are guaranteed against any manufacturing defect for 1 year from the date of purchase If during this period of time any anomaly were to be detected please let your supplier or installer know The warranty covers the complete repair of the equipment that DURAN ELECTRONICA S L technical services consider to be defective so asto return the equipment to its normal use This warranty will be valid if the equipment has been installed by a competent person and following the specifications in this manual Negligent use or installation will exempt DURAN ELECTRONICA S L from responsibilities for damages caused to property and or people and from the fulfillment of the terms of this warranty The warranty does not cover Installations periodical checks maintenance and sensors past their useful life Breakdowns caused by improper handling inappropriate use negligence overload inadequate power supply or equipment neglect voltage shorts defective installations and other external causes Repairs or adjustments carried out by personnel not authorized by DURAN ELECTRONICA S L Equipment transport costs DURAN ELECTRONICA reserves the right to modify the contents of this manual without prior noti
4. CO 2nd Speed 2nd Speed instantaneous Group Vent2 100ppm 100ppm lm 2m Relay2 Spanish with 3ppm lt 3ppm None 5m 10 NO instantaneous Portuguese lst Speed lt 3ppm None 5m Vent1 only 1 group 3ppm 10ppm 1 1 gas per Relayl NO 2nd Speed instantaneous Group Vent2 5ppm 5ppm 5m Relay2 With Portuguese standard only one gas may be programmed for each module line 7 DISPLAY INFORMATION WITH A DISCONNECTED MODULE LINE Software Version Module line status 8 KEYPAD FUNCTIONS WITH A DISCONNECTED MODULE LINE Each time you need to use the keypad after the symbol n shows up in the display the engineer code 1111 default setting must be typed in 8 9 2014 DURAN ELECTRONICA S L All rights reserved www duranelectronica com 9 LANGUAGE CHANGE Press p and current language shows up Insert engineer code 1111 default setting 1 select language with p or i and press to save 10 LINE TEST This test is particularly useful to verify the type and quantity of installed detectors 150 Press Insert engineer code shows up 1111 default setting shows the number assigned to the detectors will be shown sequentially and the type of gas is for all the detectors found and is for those detectors not found or not Installed Finally the total number of detectors found will be shown The test will repeat itself sequentially To exit this mode press 11 SYSTEM PROG
5. and a four key keypad code protected 13 8V 3 7A power source with battery charge presence and status control for a battery of up to 7 5Ah plus one general fault dry contact relay output Detector operating principle Based on an electrochemical sensor that generates a current proportional and linear to the quantity of gas detected This signal is suitably analyzed by a microprocessor that together with ambient temperature data gathered by the detector itself sends the monoxide concentration data to the module line A mini version of DURPARK with the same characteristics but non expandable with one module line and 13 8V 1 6A power source is available 4 9 2014 DURAN ELECTRONICA S L All rights reserved www duranelectronica com 2 PREVIOUS CONSIDERATIONS For grid power supply 230 VAC to the panel it is recommended to have an independent outlet protected with a 10A bipolar magnetothermal switch For the correct operation of the various anti parasitic systems included in the equipment it is necessary to have a good ground connection Carry out cabling for the relay outputs through different cable ducts than those of the detection lines O For the activation of the ventilation motors contactors controlled by the module line relay outputs must be used never the relay contacts directly O Do not drill holes in the cabinet use the precut holes provided To prevent interferences do not install the equipment and or
6. maximum length recommended 3 wire 3 x 1 5 mm communications Maximum number of detectors per module line Up to 16 detectors CO and NO simultaneously Programmable reading modes Sequential or maximums per group 16 x 2 lines of alphanumeric characters backlit LCD display 3 leds 3s per detector sequential mode and 3s In total for maximums reading mode 3 independent per module line 3A 250V AC dry contact fuse protected auntie 1 for line power supply 12V 3A protected with automatic reset fuse and 1 for battery 12V DC 7 5 Ah fuse protected 12V DC 3 3Ah in the Mini Durpark one module line version Data presentation per module line Reading speed General fault output 1 Potential free contact C NC on standby 13 8V 3 4A Durpark 1 to 4 module lines switched power source 13 8V 1 6A Mini Durpark 1 module line 120 240V AC 47 63Hz Mains input 10W Durpark 4 module lines 3W Mini Durpark 1 module line 390x290x125 1 4 module line control panel Cabinet dimensions in mm 280 x 213 x 83 Mini Durpark 1 module line 6 Kg modular control panel from 1 to 4 module lines Weight Kg 150gr per additional module line 3 Kg Mini Durpark 1 module line Protection grade IP30 o Power supply cables cross section and maximum distances change depending on the quality of the cable employed total consumption of the detectors connected and their distribution throughout total cable length I manDURPARK v02 1 9 25 D
7. Exit programming Only if Portuguese standard is programmed If once inside this mode no key is pressed for 30 secs the system will automatically exit to the initial OFF position Once Inside programming mode Press to enter the desired menu option 2014 DURAN ELECTRONICA S L All rights reserved www duranelectronica com Press p to increase selection d Press to decrease selection Press to memorize selection 12 DURPARK CO NO DETECTOR CALIBRATION eo This detector is guaranteed to stay calibrated throughout its useful life however if you decide to proceed with recalibration do so in the following manner This operation must only be carried out by personnel with adequate training They must possess the adequate tools and a test bottle with a gas concentration of 150ppm A precise mixture of CO and synthetic air for the calibration of CO or a bottle of 10ppm a precise mixture of NO and H for If this adjustment is carried out in environments where a presence of gas 15 suspected it will be necessary to use an N Nitrogen bottle for correct zero adjustment Concentrations of 100 150 and 200ppm for CO and 5 10 and 15ppm for NO may be chosen Enter calibration menu a sequence searching for the detectors will start When this is finished the following will show on the screen Press to choose a detector and to proceed with its calibration Select cali
8. RAMMING ENGINEER MODE MODULE LINE OFF If you do not need to modify any parameter go directly to module line start up in page 14 If you need to change any parameter Press 1111 default setting The first menu that shows up is 1 standard I manDURPARK vO2 9 10 1 2 3 4 5 Group Engineer Program Clear Standard Configuration Code Reset Events Line Sensors Detectors Program Test Test Calibration Test Exit Press to advance up to the menu you want and enter by pressing To move through the different menus and program the various options follow the instructions showed on the display 1 Select the standard Portuguese Spanish with 1 group or Spanish with 2 groups 2 Select the type of gas for the group CO or NO Ventilation level 1 Ventilation level 2 Alarm level Ventilation activation delay and Ventilation deactivation delay 3 Change engineer code 4 Erase all programmed inputs and reset to default parameters 5 Set events memory to zero 6 Allows verifying the correct communication of all detectors connected to the line walk test Detectors will start with the following sequence 0 9 0 9 7 Allows carrying out a sensor status test without using gas See page 12 8 This menu lets you calibrate all detectors in the line one by one See page 11 9 this menu you can verify each detector reading in real time Specially useful to verify detector response with gas 10
9. TION 11 RECOMMENDED PATTERN GAS AND GAS FLOW FOR 12 INTERPRETATION OF THE DISPLAY IN TEST MODE FOR CO 5 5 5 12 DETECTOR TEST 3064 WA PR Pd EY ES daa eri br Leu aci pP VE EF RT EINGP Ud ES 13 MODULE LINE STARISUP EP Lb ELA RE TRI ROC CP OC 14 DISPLAY INFORMATION WITH A CONNECTED MODULE LINE 15 DETECTOR LED CODES 3i RR d C OCT COE ERU RIS 15 MODULE LINE LED INFORMATION 16 KEYPAD FUNCTIONS WITH A CONNECTED MODULE LINE USER 16 CHANGE OF VENTILATION 18 ACOUSTICS INHIBITION ia CIRCE GERE n CC aces 18 MODULE LINE BEHAVIOUR IN CASE OF POWER 19 MODULE LINE TECHNICAL 5 5 19 DURPARK CO 3 WIRE DETECTOR TECHNICAL 5 5 20 DURPARK DETECTORS GENERAL CONNECTIONS 3 21 PARALLEL CONNECTION OF CO AND NO RELAYS TO A SINGLE 22 WARRANTY ud ir S bane d Edu Ed 23 I manDURPARK vO2 3 1 INTRODUCTION DURPARK has been designed for the detection of up to two different g
10. URPARK CO NO 3 WIRE DETECTOR TECHNICAL CHARACTERISTICS Power supply tension V to 15V DC Consumption mA endby24mA lar Measuring range From 0 to 300ppm CO and 0 20ppm NO Resolution lppmCOos05pmNO 00 Repeatability 1 and 3 respectively Linearity inethrughouisfulsale Calibration gas and recommended Precise mixture 150ppm CO N 150ml min concentration Precise mixture 10ppm 1000ml min a orng i CO and 3 Recalibration periods Calibration for life Relative humidity 7 From 5 to 90 RH without condensation Atmospheric pressure 10 Operational temperature 10 C tO 60 T90 response time 90 s CO and 30 s NO Parallel communication 77 3wires own addressable protocol 1 to 1 Protection grade IP20 Weight gr and measurements diameter 146 84 90 X 42 without base 90 X 74 with base heigth mm Approximate coverage 200 m CO following current standards 100 m NO Typical operational conditions 20 O 20 C 2 and 4076 RH 10 minimum of O 10 IM PORTANT CO DETECTORS Do not expose the detector to high concentrations of ammonia NH or to places where 9 concentrations of Hydrogen Sulfide H S might form as these will irreversibly damage the sensor Do not expose the detector to organic vapors such as alcohols acetones or volatile oils Exposure may cause temporary d
11. ases CO and NO simultaneously in the same module line Specially suitable for use in car parks machine shops garages and small installations in general Expandable from one to four zones and capable of controlling up to sixteen detectors per module line by a three wire connection up to a distance of 400 500 meters It includes three voltage free relay switching outputs Vent1 Vent 2 and Alarm and therefore up to three programmable independent actuating levels in each module line Each module line can be programmed to work according to Spanish one ventilation speed or Portuguese two ventilation speeds standards When working with Spanish standard it can be programmed to work with one or two detector groups allowing for the sectioning of the installation and for each detector group to work with a different activation output With Spanish standard if at the moment of connection the module line recognizes the presence of the two types of gas detectors CO and NO the module line will reprogram itself automatically to work in two groups and therefore with two independent relay outputs making starting up easier Three languages are available to be selected English Spanish and Portuguese Every module line has a capacity to memorize 14 different event types up to a total of 999 of each type Operating individually each module line includes a backlit 16X2 character lines LCD display plus three optical indicators internal acoustics
12. brated or wrongly calibrated detector Green sequential blinking every time detector communicated with the module line 9 9 9 Correct functioning I manDURPARK vO2 1 5 19 MODULE LINE LED INFORMATION Led 154 illuminates to indicate that the module line internal acoustics are inhibited Led illuminates to indicate any kind of fault in the module line It will reposition automatically when the cause generating it disappears Led x illuminates intermittently when the programmed ventilation level for the module line is reached and continuously to indicate the activation on any of the group ventilations it will turn off when the ventilation is disconnected or the gas level descends 20 KEYPAD FUNCTIONS WITH A CONNECTED MODULE LINE USER MODE Each time that the keypad is used after the n symbol shows on the display the 2222 default setting code must be typed in By pressing the user programming mode is entered Once inside the sequence to move and choose from the various menus is Select the menu you need with or press to enter In this mode the menus are organized as below 1 2 Reading mode User code Inhibit detector Events memory System test 1 6 2014 DURAN ELECTRONICA S L All rights reserved www duranelectronica com 1 Select between sequential and maximums reading modes In maximums mode the module line display will show the detector detect
13. bration date day month year This information is saved in the detector so it can be checked in factory zero didst E ne Wait for at least a minute and when the reading is stable press Si If the level shown the display is greater than 20 message will be shown and adjustments will not be possible but the zero data of the last calibration will be maintained If the level is correct under 20ppm it will be memorized and the option for gain calibration will be shown Press p to adjust the zero of the next detector or to adjust gain 11 I manDURPARK vO2 Press p to select your test bottle concentration and to start the calibration Circulate the gas mixture with the required flow through the calibration idSeem mask and wait at least four minutes and when the measurement becomes stable press 24 The following will be shown 41 To abort gain adjust press To exit the calibration menu from any position press If the level reached is not within 20 of the expected response will be shown and adjustments will not be possible as the sensor response will not be able to be compensated with an adequate gain factor but the data from the last calibration will be maintained Verify that the selected concentration corresponds to the one of the test bottle and repeat the process If the error persists the sensor will have to be substituted Maximum ele
14. ce I manDURPARK v02 2 3 ISO 9001 Quality Management Certificate n FS82426 NA DURAN electr nica c Tom s Bret n 50 28045 MADRID Spain Tel 34 91 528 93 75 Fax 34 91 527 58 19 durant duranelectronica com www duranelectronica com manDURPARK v02
15. ctronically compensable level 13 RECOMMENDED PATTERN GAS AND GAS FLOW FOR CALIBRATION Detector type Recommended pattern gas concentration Flow ml min NO 10ppm 400 14 INTERPRETATION OF THE DISPLAY IN TEST MODE FOR CO SENSORS shows in the position belonging to the assigned detector number if everything is correct shows up in the position belonging to the assigned detector number if there is a fault shows up in the position belonging to the assigned detector number if there is no detector connected absent 1 2 9 2014 DURAN ELECTRONICA S L All rights reserved www duranelectronica com In the example above the sensors of detectors 1 2 3 4 5 6 7 are correct number 8 has a fault 9 10 11 are correct 12 has a fault 13 14 are correct and in 15 16 there is no detector connected Absent Led alternates fast green red during verification time To find the detector in the installation once the test is completed look for A salvo of 3 red blinks with a 2 second cadence 9990 0 999 Only after carrying out a sensor life test this indicates the sensor is at the end of its useful life or in bad condition Substitute it as soon as possible with a new one Fixed green Only after carrying out a sensor life test this indicates the sensor is in good condition Test is designed to be used sporadically Do not abuse this test It may damage the sensor To exit t
16. detectors close to electrical panels motors or variable frequency drives Do not handle or dismantle any module line detector or mechanism when the equipment is powered In case of any fuse being broken always use the fuse value indicated in the documentation or in the printed circuit board Not following these indications could result in damage to the equipment The automatic reset protection fuses open when they detect a short circuit or consumption increase If this should happen disconnect the cables from the control panel terminals check the cabling check that the consumption of the elements which it is powering does not exceed fuse Capacity and wait for some time until the fuse resets We recommend carrying out the installation with 3 wire 3x1 5mm for power supply and communications and that maximum distance between the control panel and the last detector connected to the line does not exceed 400 500 meters Ensure that the connections between the module lines and the detectors are correct This is done in parallel and any kind of branching is allowed as long as the position of the negative and positive supply terminals and communications terminal are respected No resistor needed at the end of the line Before connecting the detectors to the module line make sure that these are disconnected Connect the battery respecting the polarity Red for positive and black for negative Only a 12V 7 5Ah batte
17. entilation 2 output alarm relay power supply source tension and battery status The system will exit to the normal reading mode of the module line automatically after the test is finished 21 CHANGE OF VENTILATION MODE Press and will ask for user code 2222 factory default Hentilation Mode blinking group number is shown Select poe HL Hulu 4 with or the group you want If there is more than one press select T with or between AUTO STOP MANUAL and confirm with 22 ACOUSTICS INHIBITION To inhibit acoustics press and the pertinent led will turn on and stay in this state until manually rearmed In this state acoustics will only sound if there is any type of fault in the line 1 8 2014 DURAN ELECTRONICA S L All rights reserved www duranelectronica com 23 MODULE LINE BEHAVIOUR IN CASE OF POWER FAILURE 1 In case of power failure if a battery was not installed the module line will disconnect When power is restored it will connect automatically with all the parameters that were programmed before the power failure 2 If a battery is installed the module lines will tone down the lights to save energy When the battery gets to 9V the module line will automatically disconnect Module line reconnection will be performed as above 24 MODULE LINE TECHNICAL CHARACTERISTICS Technology 8 bits microprocessor Power supply 9V to 15V DC Maximum consumption 122 mA Line
18. his mode press and all indicators will turn off and go to normal mode 15 DE TECTECTOR TEST Enter engineer mode advance up to menu 9 and press it will search and identify the type of detectors installed when finished it will show A 1 ue 1 E unm I ee esl rem T d M Y Y M briefly show in the display unit l manDURPARK v02 1 3 16 MODULE LINE START UP Press and this will show up 2222 default setting Searching for detectors in the line Number of detectors found Shows sequentially the number assigned to the detectors and the gas type Shows number of groups programmed or detected Informs about the programmed standard and Its version Shows battery state if equipped with one If not No battery shows up led will light up indicating if the error happens because the detectors or the groups have been wrongly configured Review the programming detector addressing make sure the two gases have not been included in the same group check the line cabling and try again 1 4 9 2014 DURAN ELECTRONICA S L All rights reserved www duranelectronica com 17 DISPLAY INFORMATION WITH A CONNECTED MODULE LINE Group number Gas assigned Locked Information of ventilation status per information to group keypad group AUTO STOP MANUAL VENT 1 or GR CO or NO symbol VENT 2 or MAX alternating only when the reading mode is prog
19. ing the highest gas concentration in each group or the detector with the lowest assigned number in the group if all indicate the same gas concentration for instance 000ppm 2 User code change allows the operator to change the access code for this menu 3 It allows the inhibition of detectors that are causing problems because of malfunction or decalibration Wi Press p to choose detector and to change its status between ACT or INH To exit press 4 Visualize 14 different types of events indicating how many times each one has occurred up to 999 times per event Once inside the last registered event shows up how many times it has occurred and the description When its maximum capacity is reached the first saved event is substituted by the most recent You will be able to see how many times the following incidences took place Connections Disconnections Power grid fault Battery fault Power supply source fail Detector error Number of times I manDURPARK vO2 1 7 Ventilation level 1 Ventilation level 2 Alarm level Saturation level Ventilation 1 when activated according to programmed level Ventilation 2 when activated according to programmed level Entry into user programming mode Entry into engineer programming mode To exit press 5 System test which carries out a test of the internal acoustics optical indicators verify the programmed standard Ventilation 1 output v
20. rammed to a maximums reading mode Number of Detector concentration in ppm Information on the activation detectors 001 and auxiliary messages levels reached Lve1 Lve2 NA to D16 ERROR Saturation and INH When Spanish standard and one group are programmed both ventilation relays will activate at the same time Factory programming by default is for Spanish standard and for CO If at the time of connection 2 correctly formed groups are detected detectors 1 to 8 of one gas and 9 to 16 of another the control panel automatically reprograms to 2 groups Spanish standard Unless Portuguese standard is programmed the option for programming a second ventilation level and its corresponding messages during the normal functioning of the module line will not show 18 DETECTOR LED CODES Led alternating between green and red a a PT PT PaT A Y v Initializing The detector still has not been recognized by the module line after bein a communication error when the detector has not communicated with th minutes g turned on It also e line for more than Continous red x CO DETECTORS indicates that CO concentration detected is 50 or more NO DETECTORS indicates that NO concentration detected is 3ppm or more This happens independently of the detection levels programmed in the module line Red fast intermittent Not cali
21. rifts in sensor response Do not expose the detectors to temperatures above 60 C as sensor may be irreversibly O deteriorated O Do not expose the detector to silicone vapors as this may damage the sensor High condensation inside the detector due to a sharp temperature change may cause sensor to behave erratically 2014 DURAN ELECTRONICA S L 2 0 All rights reserved www duranelectronica com 26 DURPARK DETECTORS GENERAL CONNECTIONS 3 WIRE ALARM VENT1 VENT2 220 AC Ne L ff THREE PHASE CONTACTOR CONNECTION EXAMPLE 2 E NETWORK FUSE C e G DF PAS JA MAINS INPUT 230 AC MODULE LINE N GENERAL FAULT OUTPUT POTENTIAL FREE 2 Cu 16 4 s Y REA 9 A 4 Pat 2 CONTACT ON STANBY 2 4 N DETECTOR 1 CO NO BATTERY 12V 7 5 Ah gt e Wwe Wc 57 du X du POWER SUPPLY SOURCE DETECTOR 2 CO NO DETECTOR 16 CO NO 21 I manDURPARK v02 27 PARALLEL CONNECTION OF CO AND NO2 RELAYS TO A SINGLE ACTUATION F 220V AC N 2 2 4 72 P 0 VENTA GR 87 MODULE LINE gt GM E NOTE VENT2 GR2 5 77 This 220V NO applicable to any other tension or element THREE PHASE CONTACTOR CONNECTION EXAMPLE tronica com
22. ry can be connected 3 3 Ah for the mini version I manDURPARK vO2 5 Although the equipment can work without a battery we recommend that one be used If at the moment of module line connection there is no battery present the module line will reconfigure Itself to not check battery state The optimal installation height for CO detectors is 1 8 2m from floor and its coverage is 200m according to Spanish regulations and for 1m from floor and 100m coverage approximately Do not in any case exceed the technical specifications described in the manual without first consulting our technical service O Do not install the detectors or control panels near a heat source Do not paint the detectors If you need to paint the area remove the detectors and cover the detector base If possible always install the control panels and detectors when all work has been completed in the installation 3 OPTICAL INDICATIONS All optical indications are followed by the corresponding identification message in the display unit 1 Optical indication for inhibited internal acoustics 2 Optical indication for general fault 3 Optical indication for ventilation state 6 2014 DURAN ELECTRONICA S L All rights reserved www duranelectronica com 4 PROGRAM MING DETECTOR NUM BER 5 DETECTOR NUMBERING DEPENDING ON NUMBER OF GROUPS 2 GROUPS 1 or 2 GASES GR1 DETECTORS 1 TO 8 GR2 DETECTORS 9