Home
4Straight Battery Manual - Healthcare Lifting Specialists
Contents
1. Long cable for upward movement 4 Short cable for 6 2 1 Push the safety strip through all four legs downward movement Short circuit plug red and fit it on the underside of the fascia by means of the double adhesive tape 6 2 2 Remove the red short circuit plug of the short provided cable marked in red Remove the protection paper of the tape and press on the safety strip Observe the Insert the loose cable of the safety strip into minimum bending radius 2cm inside the free socket of the control unit cable See separate instructions for mounting marked in red A and handling of the safety strip Page 8 6 3 Mounting of wheels option 6 3 1 Mount the wheels Do not forget to fit three washers on each wheel a Sm a ad 6 4 Mounting of fixed control switch option 6 4 1 Pull the cable through the front fascia and insert it into the control unit 6 5 Performance test After mounting and prior to use all functions of the table must be tested After that a performance test must be carried out at least once a year by competent personnel Testing prior to switching on power 1 Check that the mounting instructions have been observed 2 Check that all bolts have been tightened 3 Check that all cables have been connected correctly and that the plugs have been pressed home 4 There must be no load on the table 5 There must be no objects or the like preventing the table from moving freely withi
2. 6 199 6cm ae i ns u Length 35cm k zi For table top length 60 200cm Frame length always 0 4cm less than the table top i e 59 6 199 6cm Height 55 85cm H1 Height 65 95cm H2 Height w wheels 7 5cm Table size Table size 60cm lt L lt 120cm 121cm lt L lt 200cm 60cm lt W lt 120cm 121cm lt W lt 200cm Page 5 E a EN ra UN Component Item number Pcs 1 Motor 96000553 2 2 Motor cable 2m 96000573 2 3 Control unit 96000563 1 4 Side fascia shaft Hex6 Length frame width 13 8cm 2 5 Infrared control switch Ropox 1 function 96000661 1 6 Angle plate for control unit 12978802 29 1 7 Leg 1 2 8 Leg 2 2 9 Allen screw M8x16 95010003 16 10 Side fascia profile Length frame width 12 4cm 2 11 Front fascia profile Length frame length 12 4cm 2 12 Screw 24 8x13 Torx 95091012 6 13 Cover plates 50 40000 025 4 Red Black Black Red Red Black Black Red Leg 1 6 Mounting instructions description AN Mounting must always be carried out by competent personnel Prior to mounting check that all parts have been provided See list of components section 7 6 1 Assembly of frame 6 1 1 Mount hexagonal shaft and motor cable 6 1 2 Mount motor on side fascia Free cut of profile away from table top 6 1 3 Check that the height L of all four legs is 6 1 4 Now mount the two front fascias Important identical May be a
3. Declaration Product name Item number 4SingleElectric Set of legs Electric Height 58 88 cm H1 50 41120 Height 65 95 cm H2 50 41220 Front fascias for frame L xxx cm 50 43xxx Side fascias for frame W xxx cm 50 45xxx The above items conform to the following Directives and Standards DIRECTIVES EU Council Directive No 89 392 EEC concerning Machinery modified by Directive No 98 37 EC The Executive Order of the Danish Working Environment Service No 561 of 24 June 1994 with subsequent modifications 73 23 EEC The Low Voltage Directive modified by Directive No 93 68 EEC 89 336 EEC The EMC Directive modified by Directives Nos 92 31 EEC and 93 68 EEC DS EN ISO DS EN ISO DS EN DS EN DS EN DS EN The original Declaration of 13 Complaints See General Terms of Sale STANDARDS 12001 1 2003 DS EN 55014 1 2000 12100 2 2003 DS EN 55014 2 1997 527 2 2002 DS EN 60335 1 2002 61000 6 3 2001 EN 55022 Class B 61000 3 2 2001 EN 61000 3 3 1995 A1 2001 61000 6 2 2001 EN 61000 4 2 3 4 5 6 8 11 Conformity is obtainable from Ropox A S and Delivery on www ropox com Page 15 Page 16
4. BP4bhBN AAW LUI UA Ce Better ways to better days 4SingleElectric User Manual Mounting Instructions PDF 6004 01 08 2009 10 1 12 13 Contents INTRODUCTION rp sweci en teoces nares n ecw esaea Ceetee cae oe ees reece ecteasetee cate OEE eect 3 CONFORMITY WITH EU DIREC PIV ES oeiee les eed ete ee 3 APPLICATION aaiae iaaa aeieea aeaee eaea aaea eA e eeo aa Pt 3 TECHNICAL DA TA oiis AEE OERE E E EE 4 SCHEMATIC DIAGRAM OF ERAMILDB idonee aeuo or oa ee e oo ae EO EDI n d ES 5 SCHEMATIC DIAGRAM OP ERA WB i vcsnscscssisadecesocetccnshicieaszaesscelilGdicsseocedcaesbadiesectecedebii dics seouedceestadieaseoeeens 5 MOTOR 96000553 2 E te cacti Secive ot de Co E Loic Co tede Oo E SEITE E A EA 6 MOUNTINGINSTRUCTIONS DESCRIPTION 22 0 65e 055i de oec soper ce dones oe oce ctio AAE EERE S 7 vn MEE 221 XOT UT ERETETTESERSTUNH p 7 0 2 Mounu OF Sar Y IP D a sstustasiezts mu eode I oet ue ex ee obtu feed taedet Leu Uode a tei rofa see eur UR Os Monntngo wheels opon kcecotvisdisctistesvichta tpud uso en dst e tecti fatte uot edeit a ferto ues eur tdws 9 04 Mountine or fixed CONTOL SWITCH CODIIOY idest id esatesex NE de sd ete fette ta a bcd toes ee dus 9 OD Arnan TOS Ecacsaifatosc etii iid EER te i shedeu tee fale cd eise enu oh tede dentac ced qu Uds 9 LIST OER COMPONENTS eiecti erae ia ee eee es eee i esed aisi tee be i ue ce 10 OPTIONS 55 stadi ui D IEEE M E 11 SAFETY TN E Dec MP 12 CEEA
5. NING MAINTENA NCB DEP cem 13 10 leaming OF Tran isisisi taut ce do tele tu e at oo do adieu udi ito uo cda visui a its dde 13 102 MOWMCHOICO siuestonitiiscc latte ice EM eost educ alts he aiid taeda MO C cd eon itd eae oS cals ake ans 13 10 3 Service schedule operation and maintenance cesses eene eese nnne ntes sena enne ees nnns 14 TROUBLESHOOTING enn Hn M Leo DI CEU ed i eS ecd Ue Doe eod De eS C CU eu eE LEA ELE DUE 14 11 1 The frame seems loose or unstable esses eene esssne nnne ness seen rennen essen rennes 14 11 2 The height of the frame cannot be adjusted adjustment seems very difficult sees 14 11 3 The frame does not move straight ccccccccccsecccccccccccccneeeesececeeeeaseeseeeeeeeeaeeeseeeeeeeeaaaeeeeeeeeeeeaaaesseeeesessaaaaesees 14 CE DECIAXRA TION i idtitiee ie edendo heo 6000000060250 00 4063100 0092500700010200000000 0 002152091061 B fete see ceci Eas o LA ERG 15 OMPIAENTS etd eee hae o ehe it e tete E 15 Page 2 1 Introduction 4Single is a multi function table which may be adjusted electrically to suit seated or standing activities Owing to the unique design there are a variety of applications and the table is therefore also ideal for wheelchair users A This document must ALWAYS accompany the product and be read by and available to users All users must follow these instructions It is very important that the instructions have been read and understood prior to opera
6. al or international standards Page 3 4 Technical data Product name Item number Options Material Surface treatment Power supply Standby primary Control voltage Duty circle Max load of frame Speed lifting time Increased load of frame Speed lifting time Temperature Air humidity Complaints Producer 4SingleElectric Set of legs Electric Height 55 85 cm H1 50 41120 Height 65 95 cm H2 50 41220 Front fascias for frame L xxx cm 50 4 3xxx From 60 200cm at increments of 1cm Side fascias for frame W z xxx cm 50 45xxx From 60 200cm at increments of 1cm Wheels Increase the table height by 7 5cm Flexible safety strip Welded steel tubes St 37 and various plastic components Blue chromate powder coating Standard CWS 81283 RAL 7021 mat 230VAC 2 5A 50Hz 1 1W 24VDC Max 10 conform to 1 min active 9 min pause 130kg evenly distributed uu Approx 32 approx 10sec 250 kg evenly distributed option Tn Approx 12 approx 25sec 5 45 C 5 85 non condensing See Complaints page 15 Ropox A S DK 4700 Naestved Tel 45 55 75 05 00 e mail info ropox dk www ropox com Page 4 9 Schematic diagram of frame All electrical connections to the control unit must be flexible to ensure that the table moves freely within the range of adjustment Width 5cm Width 60 200cm Frame width always 0 4cm less than table top i e 59
7. crew 04 8x13 95091012 Screw 04 2x6 5 95090806 Page 10 w X iS 1 pc 2 pcs 5 pcs E 5 pcs eA gem 8 Options Split cable for control switch 96000629 To be used if more than one control switch is required Control switch small press pad 6 x 3cm 30 67840 Safety strip 30 69xxx Brake wheels black 4 wheels 50 41600 Increase the table height by 7 5cm incl 12 washers 95170510 Increased lifting power set of legs H1 50 41320 Max load 250kg evenly distributed To be ordered with main order Increased lifting power set of legs H2 50 41420 Max load 250kg evenly distributed To be ordered with main order Page 11 1 pc 1 pe A norox W 1 pc 1 set 1 set m 9 Y Vv V NN Vv VV WV VVVVV WV Safety in use 4Single must only be used by persons who have read and understood these instructions The frame is provided with an infrared remote control which must always be kept out of reach of children 4Single is an electrically operated height adjustable table and we recommend the use of a safety strip in order to prevent damage and accidents However even if this strip has been fitted always make sure that there are no persons animals or objects under the table during use 4Single is an activity table and should not be used as a lifting table or person lifter Always use the table in a manner excluding the risk of damage to persons or property The per
8. ctrical components with water Clean the frame with a wrung cloth with lukewarm water and a mild detergent Do not use enchants or abrasives or grinding cloths brushes or sponges Dry the frame after cleaning 10 2 Maintenance N Inspections service and repairs must be carried out by competent personnel The frame is maintenance free and the moving parts have been lubricated for life For reasons of safety and reliability we recommend inspection of the frame once a year Check that all bolts have been tightened gt Check that the table moves freely and without problems from bottom to top position gt Resetting of frame Press the DOWN button and adjust the frame to bottom position Press the DOWN button again and keep it depressed for 5 sec to reset the control unit Check that the movement is smooth and even Make sure that the mains cable moves freely gt Check that water connection hoses and draining hoses if available are tight and functional gt Check that cable to hotplate if available is undamaged and may move freely gt Check that all cables have been mounted correctly and are undamaged After each inspection fill in the service schedule See 10 3 Only use Ropox original spare parts for replacement of parts If other spare parts are used the right to complain may become void Page 13 10 3 Service schedule operation and maintenance Service and maintenance Serial No Service and maintenance Seria
9. djusted on hexagonal Push side and front fascias firmly against the shaft by means of the open end wrench leg before retightening the fascias Tighten provided Place side fascias on a plane the bolts securely by means of the wrench surface and mount legs See label on legs provided 6 1 5 Position the angle plate for control unit 6 1 6 1 Push the control unit over the fixture as shown and fasten it to front fascia and 2 fasten it Page 7 6 1 7 Place the frame on the table top and push the cover plates between legs and table top Centre the frame in relation to the table top 6 1 8 Fasten the tabletop with screws through the holes of the fascias Connection to control unit Connection of safety strip See 6 2 2 6 1 9 Connect the infrared receiver to the control unit Remove the protection paper and fit the receiver under the table top Place loose cables in the cable clips and fasten them under the table top cable Motor cable Cable for control switch 6 1 10 6 2 Mounting of safety stri A Option Ropox always recommends the use of safety strips on electrically adjustable frames A See the manual for strips provided AN Be careful not to damage the safety strip during transportation or mounting j If the safety strip is bent or twisted too much it may not have the intended effect In order to obtain optimum adhesion the surface on which the safety strip is to be attached must be clean and dry
10. l No Date Date Signature Signature Remarks Remarks Service and maintenance Serial No Service and maintenance Serial No Date Dato Signature Signature Remarks Remarks 11 Trouble shooting 11 1 The frame seems loose or unstable gt The screws assembling the frame have not been securely tightened gt Tighten all screws cf mounting instructions 11 2 The height of the frame cannot be adjusted adjustment seems ver difficult Check mains voltage to control unit and that the power has been switched on Check cables and plug in connections between control unit and motors Check cable and plug in connection between control unit and control switch Check connection of cables for safety strip to control unit and safety strip If no safety strip has been fitted there must be a short circuit plug on the safety strip cable See mounting instructions fig 6 2 2 If a safety strip has been fitted Check that the safety strip has not been activated Remove the short circuit plug from the safety strip to the Y cable of the control unit See mounting instructions fig 6 2 2 If the table works without connection of the safety strip the safety strip has been activated VVV WV Y 11 3 The frame does not move straight gt Ifthe frame does not move straight it must be reset see Maintenance section 10 2 N If there has been a power failure the table must always be reset before use Page 14 12 CE
11. n the range of height adjustment Now switch on power to the control unit 6 Press the DOWN button and adjust the table to bottom position Press the DOWN button again and keep it pressed for another 5sec to reset the control unit Check that the movement is smooth and even Make sure that the mains cable moves freely T Now press the UP button and adjust the table to top position Check that the movement is smooth and even Make sure that the mains cable moves freely 8 If a safety strip has been mounted under the tabletop it must be tested Press the DOWN button and let the table move 2 5cm downward while activating the safety strip The table must now stop the downward movement move1 2cm upward and stop When all these tests have been carried out the table is ready for use See Safety in use section 9 Page 9 f List of components Set of legs H1 50 41120 Set of legs H2 50 41220 Front fascias for L xxx cm 50 43xxx Side fascias for W xxx cm 50 45xxx Control unit 21 2x10 5x6 0cm 50 41500 230VAC incl mains cable 300cm Contained in control unit Infrared control 30 67847 Remote control via infrared receiver cable 250cm Operational range 150 200cm 98002014 Y cable for safety stop 98002013 End plug with resistance Adhesive plate 96000155 Strips black 96000165 Angle plate for control unit 12978802 29 Motor 96000553 Motor cable 96000573 Allen screw M8x16 95010003 S
12. son operating the table is responsible for avoiding damage or injury Children or persons with reduced observation capability should only operate the table when supervised If the table is used in publicly accessible locations where children or persons with reduced observation capability may get near the table the person operating the table must pay attention to those present in order to prevent dangerous situations Make sure that there is free space above and below the table to allow height adjustment Do not operate the table in case of defects or damage Do not overload the table and make sure that the load distribution is correct Do not use the table in an explosive environment In connection with inspections service or repairs always remove loads from the table When installing power or water connections the regulations of the national authorities must be observed Modifications which may influence the operation or construction of the table are not allowed Installation service and repairs must be carried out by competent personnel If the table has not been assembled according to these mounting instructions the right to complain may become void Only use Ropox original spare parts as replacement parts If other spare parts are used the right to complain may become void Page 12 10 Cleaning maintenance 10 1 Cleaning of frame WARNING The frame must NOT be connected to mains voltage during cleaning Do NOT flush ele
13. tion of the product The instructions should always be available to the user and must accompany the product in case of relocation Correct use operation and inspection are decisive factors for efficient and safe performance This product is electrically adjustable in height which means that there is a risk of trapping The operation must therefore be made or supervised by an adult who has read and understood the importance of section 9 Safety in use The frame is provided with an infrared remote control which must always be kept out of reach of children 2 Conformity with EU Directives This product has CE marking and meets the safety requirements of the Machinery EMC and Low Voltage Directives See separate CE Declaration section 12 If the table frame is assembled with or is an integral part of other electrical components it will be considered a new unit Therefore the assembled product must be subjected to a risk assessment to obtain CE marking 3 Application 4Single is designed to obtain optimum working height for the user It is an activity table and should therefore not be used as a lifting table or person lifter The product must be used indoor under normal room temperatures and humidity as stated in section 4 4Single is not designed for use in damp rooms The control unit has IP32 Il protection and must always be installed in accordance with the Danish Heavy Current Regulations or corresponding nation
Download Pdf Manuals
Related Search
Related Contents
Manual en PDF - electronicaflamagas.com Important Safety Information User manual - Tripmeters for rallies. Melag Melatherm Copyright © All rights reserved.