1. System Operation Security Codes Installer Code The installer programs the 4 digit Installer Code initially as part of the programming procedure The factory default Installer Code is 4 1 1 2 but may be changed in field 20 The Installer Code is the only code that can enter Programming mode and also in normal operation mode is used to enter the Master Code which allows access to the normal functions of the system Master Code In normal operation mode the Installer Code is used to enter the 4 digit Master Security Code using the keypad To enter change the Master code by installer enter Installer Code CODE key 02 desired 4 digit Master Code To change the Master code by master enter Current Master Code CODE key 02 new Master Code new Master Code again Secondary User Codes In normal operation mode the Master Security Code can be used to assign up to 6 secondary 4 digit security codes including a Babysitter Code and a Duress Code The Master Code can also be used to remove secondary codes from the system individually To assign or change a secondary security code enter Master Code CODE key User 03 08 desired Secondary Code The system will emit a single beep when each secondary code has been successfully entered To delete a secondary security code enter Master Code CODE key User 03 08 Notes All Master and Secondary security codes permit access to the system for arming
2. disarming etc e The Installer Code can disarm the system only if it was used to arm it In addition the Installer Code cannot disarm the system if it was armed by pressing and holding a Quick Arm button Babysitter Code is User Code No 7 i e it can disarm the system only if it was used to arm it In addition the Babysitter Code cannot disarm the system if it was armed by pressing and holding a Quick Arm button Duress code is User Code No 8 When this is used to perform any system operation a special code is sent to the monitoring station Instruct users to be careful not to use this code for normal usage If a secondary code is inadvertently repeated for different users the lower user number will take priority Opening and closing reports are sent for the Installer Code as No 01 with the appropriate subscriber number Master Code and set of secondary user codes are sent as Nos 02 and 03 08 respectively in Contact ID format with the appropriate user number in 4 2 it is 1 8 Quick arming is reported as user 00 Panic Keys There are three panic key pairs that if programmed can be used to manually initiate alarms and send a report to the central station Each can be individually programmed for 24 hour silent audible personal or fire emergency responses The panic function is activated when both keys of the appropriate key pair are pressed at the same time The panic functions are identified by the system as follows Important F
3. e To turn Test mode on C OO To turn Test mode off 7 CJ CJJ To use the defined AUX function Press and hold key 2 secs 4 beeps CL LOU LO LOJ To define AUX function LJ O LI 1 action separated by terminated by To send message to pager Press and hold key 2 seconds 4 beeps Speaker Phone Operation LYNXR EN Only NOTE To place a call or answer a call using the speaker phone The ARMED and READY LEDs blink alternately when the Speaker Phone is active To flash switch between two calls using call waiting To hang up and exit speaker phone mode To enable disable toggle ringer To return the keypad to telephone mode after disarming the system 40 System Operation Remote Phone Control Feature The remote phone control feature which must be enabled in field 91 allows the user to access the security system from any off site touch tone telephone The control will pick up the incoming call based on the ring count specified in field 95 and will announce SYTEM every three 3 seconds for the next eight 8 seconds During this period the panel will wait for a valid User Code to be entered If a valid User Code is not entered or the eight 8 second period expires a modem tone will be generated for remote programming Compass Downloading If a valid User Code has been entered the control will announce the current system status and or beeping sounds Keypad Functio
4. e LJ OJ LJ J or installer code 3 To restart exit delay applies only if system is armed in Stay mode To arm in AWAY mode LJ COJ LOL or installer code 2 To arm with NO DELAY J G CG C Away or To arm if Quick Arm is programmed or hold down for at least 2 seconds To disarm the system and silence alarms J BGA To bypass a zone s OOL 2 digit zone number s To turn Chime mode on or off Message Center NOTE To record a message If a 5827 or 5827BD Wireless keypad has been installed it cannot be used to activate message playback recording programming the real time To stop recording before end of 20 seconds clock or scheduling remotely In this case you must use the master To play back a message a keypad on the control panel to perform these functions Volume Control To adjust message playback system announcement volume 3 or 6 To mute system announcements FUNCTION VOLUME To restore unmute announcement amp volume 3 or 6 Other Functions To set the time and date L JCJ LJ LJ 63 To set the scheduling OOL 64 To activate or deactivate X 10 devices 1 6 or device number To activate or deactivate X 10 devices7 amp 8 CJC JL JLJ or dev no To add a user code CLICICICI user number user s code master code To delete a user code except Master Code C COJ LO LO user number master cod
5. elay time The alarm sounder and keypad sound continuously until the system is disarmed or timeout occurs An Exit Alarm message is sent to the central station The EA display etc will also result if an alarm from an exit or interior zone occurs within two minutes after the end of an exit delay In any of the above cases use a second OFF sequence code plus OFF key to clear the display Trouble Conditions The word FAULT on the keypad s display accompanied by a rapid beeping at the keypad indicates that there is a trouble condition in the system Pressing any key can silence the audible warning sound Instruct users to call for service immediately upon seeing any of the following messages Fault and Battery Displays e A display of FAULT and one or more zone numbers indicates that a problem exists with the displayed zone s and requires attention After correcting the problem the display can be cleared by entering the security code plus the OFF key twice e The fault condition may also be caused by some change in the environment that prevents the built in receiver from receiving signals from a particular wireless sensor e A display of LOW BAT with no zone number indicates that the system s backup battery is weak e A display of LOW BAT with a zone number and a once per 45 seconds beeping at the keypad indicates that a low battery condition exists in the wireless sensor displayed zone 00 indicates a wireless button ke
6. g the 7 key on the touch tone phone Selecting another operating mode also resets the session an additional 5 minutes During the last minute of the 5 minute session the LYNXR EN generates two beeps every 30 seconds to alert the Central Station operator that the session is about to time out The Central Station operator may then extend the session by pressing the 7 key on the touch tone phone If the session is not extended the phone line is disconnected and the session is ended Sessions may be ended at any time by pressing the 9 key on the touch tone phone The AVM modes are described as follows Note When entering AVM commands make sure the Central Station receiver has been disconnected from the phone line otherwise AVM commands may not go through Key Function 1 Talk Mode Pressing the 1 key on the touch tone phone enables one way voice communication from the central station to the violated premises and allows the operator to talk communicate through the LYNXR EN speaker In this mode the ARMED red and READY green LEDs blink alternately 2 VOX Voice Mode Pressing the 2 key on the touch tone phone enables two way voice communications between the central station and the violated premises In this mode the ARMED red and READY green LEDs blink alternately 3 Listen Mode Pressing the 3 key on the touch tone phone enables one way audio from the violated premises to the central station The Listen Mode is the start u
7. ns Remote Phone Control Feature Quick Arm Note To remotely disarm system _ CJ C3 C3 1 The installer code To remotely arm in AWAY mode _ LJ LO LU 2 and babysitter code To remotely arm in STAY mode J G A _ 3 cannot disarm the 7 system if armed by To remotely arm in AWAY or STAY with no delay 7 LJ LO LO 2 or 3 0 Quick Arm method To remotely activate X 10 devices 1 6 4 device no To remotely activate X 10 devices 7 amp 8 C LO LO LJ 4 device no To remotely deactivate X 10 devices 1 6 7 device no To remotely deactivate X 10 devices 7 amp 8 C LJ LO LO 7 device no To remotely Bypass zones C CJ _ _ 6 zone no To remotely activate Forced Bypass C LJ LO LO 6 To remotely check system status To end remote phone control session Hang Upor J LA LOL 9 UL Alarm audio verification cannot be used for UL installations Alarm Audio Verification Two Way Voice Feature This feature allows the central station operator to listen talk to or conduct a two way conversation with an individual s at the premises It also assists the operator in gathering information about the nature and location of the alarm that may be helpful in responding to police and fire departments All LYNXR Series control panels are capable of supporting the Two Way Voice feature however only the LYNXR EN has this feature built in The LYNXR LYNXR24 requires
8. or the silent panic functions to 1 amp 95 be of practical value the system must be C1 amp 4 99 connected to a central station 3 amp 96 Keys Displayed as Zone 39 System Operation Keypad Functions The keypad allows the user to arm and disarm the system and perform other system functions such as bypassing zones Zone and system conditions alarm trouble bypass are displayed in the display window When an alarm occurs keypad sounding and external sounding will occur and the zone s in alarm will be displayed on the keypad Pressing any key will silence the keypad sounder for 10 seconds only once Disarming the system will silence both keypad and external sounders When the system is disarmed any zones that were in an alarm condition during the armed period will be displayed memory of alarm To clear this display simply repeat the disarm sequence enter the security code and press the OFF key The keypad also features chime annunciation and 3 panic key pairs for silent audible fire or personal emergency alarms These keys can notify the central station of an alarm condition if that service is connected A summary of system functions is provided below for more detailed information refer to the User s Manual Security Functions Empty boxes represent the user s security code Checking system status STATUS high level messages press STATUS again for secondary messages To arm in STAY mod
9. p default mode of the voice feature and allows the operator to listen through the LYNXR EN microphone This mode does not affect the existing LED pattern 7 Extends the session 5 minutes without changing its operating mode g Ends the session and disconnects the phone line 435 System Operation Powerline Carrier Devices e g X 10 devices If Powerline Carrier Devices are used two keypad entries available to the user are included They can manually activate or deactivate the device s for starting or stopping some action such as turning lights on or off etc These keypad entries are Security Code 4 Device activates starts that device Security Code 7 Device de activates stops that device Code is required for devices 7 and 8 Code is not required for devices 1 6 Exit Error Alarm Displays If programmed e A display of CA and a zone indication will appear if an exit or interior zone contained a fault during closing at the time the exit delay ended e g exit door left open but the system was disarmed during the entry delay time The alarm sounder and keypad sound continuously but stop when the system is disarmed No message will be transmitted to the central station A display of EA and a zone indication will appear if an exit or interior zone contained a fault during closing at the time the exit delay ended but the system was NOT disarmed during the entry d
10. the installation of the Audio Verification Module LYNX AVM For further information regarding the LYNXR LYNXR24 Two Way Voice Feature refer to the LYNX AVM Installation and Setup Guide The LYNXR EN does not make system announcements when the Two Way voice feature is active Activation The LYNXR EN sends the alarm message followed by a Listen in to Follow message Contact ID code 606 to the Central Station The Listen in to Follow message causes the Central Station s digital receiver to temporarily hold the phone line for approximately 1 minute When the LYNXR EN receives the kissoff from the central station indicating that the alarm message has been received the Two Way Voice AVM feature is activated in the default Listen Mode and sirens and keypad sounds are discontinued The LYNXR EN transmits a beep acknowledgment to the Central Station once per second The beep alternates between two tones and indicates that the LYNXR EN is waiting for a session command from the Central Station operator Once a command is issued the beep acknowledgement is discontinued however if a command is not issued within two minutes the system will time out and the call will be terminated System Operation Operator Commands The Central Station operator begins the session which last 5 minutes by entering one of the valid AVM commands shown in the table below The session may be extended 5 minutes without changing the operating mode by pressin
11. ypad If the battery is not replaced within 30 days a FAULT display may occur Power Failure e If there is no display at all and both indicators are not lit operating power for the system has stopped and the system is inoperative e If the display is lit and the AC display is off the system is operating on battery power only e During an AC power loss the backlighting will turn off and the indicators will flicker slightly to minimize deep discharge of the battery Other Displays dI Busy Standby Displayed upon power up After approximately 1 minute the green READY LED should light If the dI remains displayed for more than 1 minute the system is disabled To bypass the 1 minute delay press 0 CC Modem Comm The system is in communication with the central station for change of function or status verification FC Comm Failure A communication failure has occurred This message clears only when the system is subsequently armed 90 RF Jam The system has detected an RF jamming condition or excessive interference PH Speaker Phone Mode The system is in Speaker Phone mode PC Phone Control The remote Phone Control feature is active 2432

Download Pdf Manuals