USER MANUAL - Pro Audio Centre
Contents
1. www prolight co uk
2. www prolight co uk LEDJ 3 x 2M Cloth 8 Controller Order code STAR19 3 x 2M System USER MANUAL LEDJ 3 x 2M Tri Cloth 8 Controller Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications and damage to the wiring loom inside the cloth are not subject to warranty LEDJ 3 x 2M Tri Cloth amp Controller Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular cautio
3. DMX LED is lit Now choose one of the two DMX channel modes by setting dipswitch 10 to the ON or OFF position Dipswitch 10 set to OFF 7 channel mode Dipswitch 10 set to ON 3 channel mode Master slave mode set the x 2M Tri Cloth as a master unit use any of the above modes and set dipswitch 10 to the ON position and the corresponding mode LED will flash to indicate the master setting To set the 3 x 2M Tri Cloth as slave unit s set dipswitch 10 to the OFF position and the corresponding mode LED will stay static to indicate the slave setting and will now follow the master unit LEDJ 3 x 2M Tri Cloth amp Controller DMX charts 3 channel DMX chart 7 channel DMX chart 000 004 005 009 010 255 Function Red Green Blue Master dimmer 0 100 No strobe Strobe 1 25Hz RGB mode 025 029 RGB smooth mode reversed Blackout Red Green Blue Yellow Cyan Purple White Programme 1 130 134 macro 1 auto 135 139 sound Programme 2 Programme 3 Programme 4 Programme 5 Programme 6 Programme 7 Programme 8 Programme 9 No function Music control No function Normal speed Stop Speed increase slow to fast LEDJ 3 x 2M Tri Cloth amp Controller DMX Set DMX Control Mode Operating a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual
4. trait of the fixture and each fixture independently Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture reguires a start address from 1 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a
5. HIS UNIT CONTAINS NO USER SERVICEABLE PARTS WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this eguipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property LEDJ 3 x 2M Tri Cloth amp Controller Technical Specifications You should find inside the carton the following items 1 3 x 2M Tri Cloth 2 Instruction manual 3 Controller Technical Specifications Controller Power consumption 8W DMX channels 3 or 7 selectable Power supply 100 240V 50 60Hz DMX sound active auto and master slave modes Curtain 40 x 5mm tri colour LEDs Dimensions 3 x 2M 3 pin XLR in out sockets Weight 5Kgs IEC Power in socket Controller Dimensions L x W x H 191 x 160 x 41 mm Cloth Weight 1Kgs Hanging tabs on 3 sides Fire retardent material 1 2 3 4 5 Overview 1 Power input 2 Power on off switch 3 DMX in 4 DMX out 5 Data out 6 Mode indicators 7 Microphone 8 Mode control 9 Dipswitches 10 Speed sensitivity control 11 Mounting holes 8 9 10 LEDJ 3 2M Tri Cloth amp Controller Operations Quick control guide asma faasoa Rea Gren Bue veto oyan Pue ww vo
6. a von Auto mode Program 1 9 OFF Stand Alone Program 15 ON Master Operations Sound active mode To set the 3 x 2M Tri Cloth into the SOUND ACTIVE mode scroll the CONTROL MODE disc counter clockwise until the SOUND LED is lit The 3 x 2M Tri cloth will now randomly run through the colour macros and the preset built in patterns via the beat of the music To adjust the sensitivity level scroll the SPEED SENSITIVITY disc to the desired level setting Auto mode To setthe 3 x 2M Tri Cloth into the AUTO mode scroll the CONTROL MODE disc counter clockwise until the AUTO LED is lit The 3 x 2M Tri cloth will now run through the colour macros and the preset built in patterns To adjust the speed level scroll the SPEED SENSITIVITY disc to the desired level setting Colour Mode To setthe 3 x 2M Tri Cloth into the AUTO mode scroll the CONTROL MODE disc counter clockwise until the COLOUR LED is lit You can now choose the macro colours by switching any ofthe dipswitches 1 8 to the ON position Dipswitch 1 Blackout Dipswitch 2 Red Dipswitch 3 Green Dipswitch 4 Blue Dipswitch 5 Yellow Dipswitch 6 Cyan Dipswitch 7 Purple Dipswitch 8 White NOTE Only one colour can be used at a time never set two or more to ON DMX mode To set the 3 x 2M Tri Cloth into the DMX mode scroll the CONTROL MODE disc counter clockwise until the
7. fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable reguirements for DMX operation e The LEDJ 3 x 2M tri cloth can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller reguire a standard 3 pin or 5 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please guote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split LEDJ 3 x 2M Tri Cloth amp Controller DMX Set Notice e Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out 3 pin XLR DMX 512 in 3 pin XLR JA E XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground Q Pin 2 Negative A FIGURE 3 FIGURE 2 Special Note Line termination e When longer runs
8. n Never remove warning or informative labels from the eguipment Do not open the eguipment and do not modify the eguipment Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the eguipment indoors Do not expose to flammable sources liguids or gases Always disconnect the power from the mains when eguipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 100v 240v Make sure that the power cable is never crimped or damaged Check the eguipment and the power cable periodically If the eguipment is dropped or damaged disconnect the mains power supply imme diately Have a gualified engineer inspect the eguipment before operating again If the eguipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might dam age the eguipment Leave the eguipment switched off until it has reached room temperature If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a gualified technician T
9. of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a O DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion 5 Pin XLR socket i Pin 1 GND screen T 3 Pin XLR socket Pin 1 GND seteen Pin 2 Signal Pin 3 Signal Q i 5 Pin XLR socket 3 Pin XLR socket 2 1 GND screen Pin 1 GND screen 0 Pin 2 Signal Pin 2 Signal Si Pin 3 Signal in 4 Pin 5 DMX Set LEDJ 3 x 2M Tri Cloth Controller DMX dipswitch reference chart Dip Switch Position I O E 5 a 5 5 Ed 305 SOT 2 075 273 305 337 359 433 485 07 FS EJE 45 88 282 ara 348 378 aro 422 fara 505 283 315 397 379 Jani 483 LEDJ 3 x 2M Tri Cloth 8 Controller Notes LEDJ 3 x 2M Tri Cloth 8 Controller Notes
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 A Fighting Game of Sorts User Manual Online Backup Client User Manual Dolmar PS-401 User's Manual ハードウェアマニュアル - IDEC AUTO Samsung LE32S62 User's Manual 6 Ton Horizontal/Vertical Bottle Jack Combics 2 - Precision Weighing Balances Presents Sartorius 樹木・抜根・廃木材の破砕に威力を発揮! Copyright © All rights reserved.