Home
TEMPERATURE SENSORS & TRANSMITTERS
Contents
1. ia Trigger alarm conditions with thermal data for process and quality control e Measure minimum maximum and average temperatures e Record and playback thermal images of moving processes to pinpoint potential problems Features e High resolution radiometric thermal im age transmitting detailed temperature information over a high speed digital connection e Designed for harsh industrial environments ensuring ulti mate measurement reliability and availability e Sealed industrial enclosure designed for installation in the plant or the control room e Optional industrial processor unit with touchscreen provides local display and control e Wide ambient temperature capability 40 to 120 F ensures that imager can be used in even the harshest environments Integrated manual pan and tilt mount makes it easy to align the unit after installation e Flexible interface provides connections to a wide range of standard industrial interfaces TCP IP OPC analog signals or alarm outputs e High performance air purge design keeps lenses clean for optimal performance in industrial environments e Full range of analysis and process control functions point or area temperature measurement temperature profiles histo grams isotherms measurement trending and digital Zoom e Thermal analysis software lets you monitor or control up to four imagers at full frame rate Specifications Imager Model FTI E 8
2. Optional Certificate None 316 SS customer tag wired on 4 line 28 char line None Carbon steel mounting bracket for 2 pipe Stainless steel mounting bracket for 2 pipe Two DIN rail mounting clips Top Hat or G Rail None Internal surge lightning Printed English Operation Manual No transmitter configuration calibration certificate Transmitter configuration calibration certificate No certificate of conformance origin Certificate of conformance origin No Additional Features Approvals Body Type Location or Classification No certificate included See standard approvals above Explosion prf Dust ignition prf Intrinsically safe Non incendive Factory default configuration 00_ _ Transmitter configuration TC _00 __TG Class Div 1 Gr A D Class Il Ill Div 1 Gr E G Class Il Ill Div 1 Gr A G Class Div 2 Gr A D Suitable for Class Il Ill Div 2 Gr F G Class l Div 1 Gr B D with Indicator Class Il IIl Div 1 Gr E G Class Il Ill Div 1 Gr A G Class Div 2 Gr A D Suitable for Class Il Ill Div 2 Gr F G FM Intrinsically safe Class l II III Div 1 Gr A G Non incendive Class l Div 2 Gr A D Class Il Ill Div 2 Gr F G Notes and Restrictions j Available only with explosion proof field mount housing k Available only on integral mount models no integral meters Explosion prf Dust ignition prf Intrinsically safe Non inc
3. 01 U0 SIOSUSS JINJeJodWwa SWa sKs pue SJUaWUNAYSU Je217 jeuy I 2s Programming Options Startat Page STT170 SITRANS TH100 SITRANS TH200 SITRANS TH300 SITRANS TF SITRANS TEMPERATURE amp TRANSMITTERS PIG Coes OAPs FPE smana t 1 N gt Fax 630 595 2386 Choosing the Right Temperature Transmitter Honeywell SIEMENS A Pyracon Inc f f f Programmable with STT17C software Available with FM CSA and ATEX approvals 1500 VAC isolation DIN rail or pipe mount HART programmable Built in digital display FM CSA approved 500 VAC isolation HART or SCT3000 programmable optional integral analog or digital indication meter Programmable with Honeywell MC Toolkit Available with FM and CSA explosion proof housing Head mount transmitter Programmable with SIPROM T Isolated 1kV input against output FM ATEX approvals available Head mount transmitter Programmable with SIPROMT Isolated 1kV input against output FM ATEX approvals available Head mount HART transmitter Programmable with SIMATIC PDM Isolated 1kV input against output FM ATEX approvals available Head mount transmitter Profibus PA model programmable with SIMATIC PDM Foundation Fieldbus model programmable with 375 handheld and AMS FM ATEX approvals available Field transmitter for harsh environments Programmable by SIMATIC PDM or SIPROM T depending on built in head trans
4. 10 ambient See page 484 for emissivities of common materials Software Features Simple installation with customized configurations e Extensive storage display and analysis capabilities e Simultaneous process temperature data from multiple sensor heads database and archive files e Displays include thermal map temperature profiles 3 D two inde pendent zone models center line deviation subtracted thermal map and envelope profile Spot temperatures analyzed at any point e Detailed user defined zone temperature analysis e Flexible digital and analog input output options The new Landscan Thermoforming software is specifically designed to provide critical information through live configurable displays process control system interfaces and product database statistical summaries for quality assurance purposes The software calculates and corrects for the distortion of thermal profiles caused by movement of the heated sheet on rotary machines during the thermoforming process allowing accurate determination of zone heating temperatures e e a e SS Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales lesman com Provide your plant operators real time information for quality control and process data e Record ideal thermal profile and con tinuously monitor to check deviations in the process for comparative analysis
5. 132 90 179 00 225 10 271 20 317 30 Assembly Options Omit if no option is required Catalog Number Price Adjustable Steel Mounting Flange 15 00 Cast lron Aluminum Explosion Proof Head Thermocouple Insulated from Protection Tube 8 00 3 4 NPT Steel Welded Bushing 1 2 Pipe Only 1 NPT Steel Welded Bushing 1 27 3 4 Pipe Only 1 1 4 NPT Steel Welded Bushing 1 27 3 471 Pipe Only 1 1 2 NPT Steel Welded Bushing 1 27 3 47 1 Pipe Only 3 4 NPT 316 SS Welded Bushing 1 2 Pipe Only 1 NPT 316 SS Welded Bushing 1 27 3 4 Pipe Only 1 1 4 NPT 316 SS Welded Bushing 1 27 3 47 1 Pipe Only 1 1 2 NPT 316 SS Welded Bushing 1 27 3 471 Pipe Only U U Substitute the insertion length in inches measured from tip to bottom of bushing for the U U Omit this length if you would like the bushing supplied loose on the protection tube Wisconsin and Upper Peninsula Michigan Phone 800 953 7626 630 595 8400 www lesman com Phone 800 837 1700 262 923 1790 Fax 630 595 2386 sales lesman com Fax 262 923 1797 SENSORS V02 2011 Need Thermocouple Parts or Accessories All of our thermocouple parts and accessories are available to ship within 5 working days Call for current pricing and available materials and sizes Straight Elements Straight Bare Elements Metal Protection Tubes Readjustable Compression and Spring Loaded Fittings TEMPERATURE 121 L iim
6. TEMPERATURE SENSORS amp TRANSMITTERS Ba A L CONTENTS fu c DO All Lesman thermocouples and RTDs are made to your exact specifications If you can design describe or draw the temperature assembly you need we can supply it without the custom costs Need to measure temperatures in hot DE processes Take a look at Ametek Land infrared scanners and thermometers A Lesman can help you find the best temperature transmitter match for your process Whether you need HART com 3 munications digital displays or a simple DIN rail mounted transmitter it s all here v ay Lesman Online Pressure Temperature Level Flow Analytical Products E O x Due to manufacturer agreements not all products are available in all geographic areas and markets File Edit View Favorites Tools Help Back gt amp 2 ah a Ol Download Lesman Catalog Updates from http www lesman com catupdates html Some products are not available in all Lesman markets or geographic areas Prices See Startat Page Prices in this catalog are current at the publication date and are subject to change without notice Controllers and Programmers Infrared Temperature Measurement Ametek Land FTI E Fixed Thermal Imaging System 127 Ametek Land Landscan LSP Infrared Scanners 126 Ametek Land SoloNet Web Ready Infrared Thermometers 123 Ametek Land System4 Infrared Temperature Measurement Systems 124 S U Res
7. 0 1 span 0 1Q or 10uV RTD 0 1 span 0 035 span 0 025 span 0 025 span 0 45 F or 0 1 span Varies by Input Varies by Input Varies by Input RTD 0 18 F T C 1 8 to 3 6 F mV 40 vV 0 81 F 0 2 full scale 115 00 395 00 480 00 892 00 105 00 255 00 368 00 557 00 423 00 446 00 129 135 130 131 132 133 133 132 134 134 Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales lesman com Honeywell Programmable Temperature Transmitters STT171 Features Analog 4 20 mA output e RTD or Ohm input DIN Form B head mount e NAMUR NE43 sensor error response e Configurable using STT17C configuration tool and PC STT17H Features e HART 4 20 mA output e RTD thermocouple Ohm or mV input e Single or dual difference or average sensor input DIN Form B head mount e HART multidrop capable e NAMUR NE43 sensor error response e Galvanic isolation e Configurable using STT17C configuration tool and PC or HART field communicator Honeywell s STT1 70 series of programmable temperature transmitters provides cost effective solutions for temperature monitoring applica tions Compared to direct wired temperature sensor monitoring points STT170 transmitters deliver increased accuracy safety and reliability plus they redu
8. 3 7 to 22 mA DC Calibrated Output Range 4 to 20 mA DC Output Resolution 0 002 mA D A Accuracy 0 035 span total analog accuracy is the sum of the digital accuracy and the D A accuracy RTD Excitation Current 200 uA typical Input Impedance T C or mV gt 10 megohms Common Mode Rejection gt 120 dB 50 60 Hz Normal Mode Rejection gt 60 dB 50 60 Hz Input Output Isolation 500 VAC Operating Temperature Range Humidity 40 to 185 F 40 to 85 C 5 to 95 RH non condensing Storage Temperature Range 58 to 212 F 50 to 100 C Temperature Effect 7 C 0 2 uV C 0 005 input reading C CJC mV 0 2 uV C 0 005 input reading C Ohms RTD 0 0020 C 0 005 input reading C Cold Junction Compensation 0 005 C C Loop Supply Voltage 13V load resistance x 20 mA min 30V max Power Supply Effects 0 005 span volt Non Destructive Input 30 volts peak RFI Effect lt 1 with no abnormal behavior at 10V m 450 MHv Stability 0 1 or 0 1 C whichever is greater for six months with constant reference to conditions HART Protocol Supports HART universal commands 0 1 2 3 6 11 19 as well as Standard Practice Commands 34 35 36 Approvals Classified as non incendive for Class 1 Div 2 T Group A D hazardous classified indoor locations Transmitter Housing Injection molded high impact ee conductive plastic meets flammability requirements of UL94 V O Input Type Pt100 DIN IEC
9. 328 to 1112 F 200 to 600 C 90 F 50 C 100 to 1100 mV 20 mV 400 vV 0 2200Q 250 0 250 180 F 100 C 72 F 40 C ee NA NA NA NA NA NA NA mV Sensor Resistance Sensor Resistance Sensor e Pt100Q RTD thermocouple and linear voltage inputs e Varnished die cast aluminum or high grade steel IP68 rating ATEX EEx d approval FM intrinsically safe and explosion proof e Local indicating display option 5 digits 99 999 TF with TK head mount transmitter 6 5 to 35 VDC power supply programmable with TF with TK H head mount transmitter 8 to 35 VDC power supply programmable by SIMATIC PDM or HART communications device e Remote sensor mount capability allows the electronics to be isolated from high process temperatures and vibration i Please submit orders to Siemens Industry Inc Model Selection Guide c o Lesman Instrument Company Catalog Description Number Siemens SITRANSTF Temperature Transmitter Two wire system 4 20 mA output electrical isolation 1 2 14 NPT screwed gland connection user manual SITRANS TF 7NG313_ 423 00 None None FM CSA Protection Integrated SITRANS TH200 Transmitter SITRANS TH200 FM CSA SITRANS TH300 HART SITRANS TH300 HART FM CSA Housing Diecast Aluminum AC 0 00 Stainless Steel Precision Casting EC 797 00 Indicator None 0 00 Digital Display 229 00 Mounting None Bracket Carbon Steel Stainless Steel SIPROM T Parameterization So
10. Extensive diagnostics and simulation mode SITRANS TH400 is available either with PROFIBUS PA or FOUNDATION Fieldbus FF It is designed to support all common RTD thermocouple resistance and millivolt sensors Setup is quick and easy with SIMATIC PDM PA or AMS and handheld communicator FF Due to it small size the device allows flexible mounting options even in a DIN e Rugged design fully potted electronics Galvanic isolation for accuracy and safety in thermocouple applications e ATEX cFMus intrinsically safe non incendive models available e High accuracy over ambient temperature range Submit orders to Siemens Industry Inc c o Lesman Instrument Company Model Selection Guide Catalog Description Number Siemens SITRANS TH400 Profibus PA Temperature Transmitter Non Explosion Proof Enclosure 7NG3214 ONNOO 557 00 ATEX FM Explosion Proof Enclosure 7NG3214 OANO0O 597 00 Illinois Indiana Missouri and lowa Lesman Instrument Company Wisconsin and Upper Peninsula Michigan Phone 800 953 7626 630 595 8400 www lesman com Phone 800 837 1700 262 923 1790 Fax 630 595 2386 sales lesman com Fax 262 923 1797 SIEMENS Two Wire Head Mount Transmitters for Universal Inputs SITRANS TH200 and TH300 are designed to support all common RTDs thermocouples resistance and millivolt sensors Unique user friendly details are implemented Without opening the 4 20mA loop the output current can read directly with
11. Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Features e Available in any length e 316 stainless steel sheath e 3 wire DIN standard 0 003850 temperature coefficient e 2 accuracies 0 1 and 0 01 e For temperatures from 328 to 400 F Transition fitting with spring relief good to over 400 F e Works with compression fittings 1000 RTD Assemblies with Leads For use in any application where you need an RTD Assembly comes complete with 36 Teflon coated leadwires and a transition fitting with spring relief that s good to 350 F If you need a different sheath material or a dual element just call we can make just about anything you can describe 100Q RTD Assemblies with Quick Disconnect Plugs Great for those applications where you need to disconnect the RTD from the leadwires You can also attach any length leadwire you want just by order ing your desired length of RTD extension wire see thermocouple extension wire section Assembly comes complete with standard sized plug and jack Need a dual element of different sheath material Give us a call We can get nearly anything you can describe 1000 RTD Assemblies with Termination Heads When you need a serious temperature sensor rely on the Lesman RTD With its polypropylene termination head you can quickly and easily connect conduit and wiring Need a dual element of different sheath material Call us Our factory trained
12. SJOSU DINICJO SW S S pue SJUaWUNAYSU Je217 jeuy IL 136 TEMPERATURE ACCESSORIES Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Lesman Instrument Company www lesman com sales lesman com Temperature Sensor and Transmitter Accessories MFC41 50 HART Handheld Communicator Smaller and faster than the competitor s unit with eight times the storage capacity Just 15 seconds from power up to use Powered by six AA Alkaline batteries 28 hour battery life up to 60 hours without backlight CE approved general purpose and ATEX UL approved intrinsically safe models Document and store 200 configurations Clone upload and download configura tions Offline mode for editing and reviewing ANN eriam A SCOTT FETZEA COMPANY All communicator kits include CE or ATEX approved HART communicator HART lead kit one 6 pack AA Alkaline batteries communication AC adapter dongle RS 232 serial cable universal power adapter protective boot soft carrying case adjustable shoulder strap user manual software CD with Meriam DPC manager utility for downloading and installing firm ware and device file updates Only 01 models include the subscription to the DOF download site at www meriam com Model Selection Guide Description configurations Alph
13. l R1T185L483 009 SL 8HN31 185 U10 1 2 l R1T185L483 012 SL 8HN31 185 U13 1 2 l l l R1T185L483 015 SL 8HN31 185 U16 1 2 R11T185L483 018 SL 8HN31 185 U22 1 2 R11T185L483 024 SL 8HN31 50 R11T185L483 02 5 SL 8HN31 100 R1T185L483 004 SL 8HN31 200 U4 1 2 i R1T185L483 006 SL 8HN31 200 U7 1 2 R1T185L483 009 SL 8HN31 200 U10 1 2 R1T185L483 012 SL 8HN31 200 U13 1 2 i l R1T185L483 015 SL 8HN31 200 U16 1 2 R1T185L483 018 SL 8HN31 200 U22 1 2 i R1T185L483 024 SL 8HN31 Se l R1T185L483 02 5 SL 8HN31 101 R11T185L483 004 SL 8HN31 201 U4 1 2 R11T185L483 006 SL 8HN31 201 U7 1 2 R1T185L483 009 SL 8HN31 201 U10 1 2 i R1T185L483 012 SL 8HN31 201 U13 1 2 l R1T185L483 015 SL 8HN31 201 U16 1 2 l R1T185L483 018 SL 8HN31 201 U22 1 2 R1T185L483 024 SL 8HN31 Polypropylene Screw Cover 1 2 SS Hex Fitting Cast Iron Screw Cover 1 2 SS Hex Fitting Explosion Proof Screw Cover 1 2 SS Hex Fitting 316L Stainless Steel Head 1 2 SS Hex Fitting Order a Complete Field Mount RTD and Transmitter Assembly Specification S Add the following complete part number to the RTD and thermowell ADO mASanal assembly above A complete transmitter part number looks like this Pee ee ee i T 440 385U S 50 300 F In Stock at Lesman 440 385U S 0 200 F Current lt 3 5 mA input required lt 2
14. Internal temperature compensation e 8 35 VDC power supply 30V for Ex Designed for economic use the TH100 offers low cost plant operation and reliable measurements It s the ideal replacement for over aged analog Pt100 transmitters Transmitter setup is quick and easy with SIPROM T configura tion tool which can be downloaded free from Siemens website e Ideal for Pt100Q RTD measurements 4 20 mA linear temperature output Please submit orders to Siemens Industry Inc c o Lesman Instrument Company Model Selection Guide Catalog Description Number Siemens SITRANS TH100 Temperature Transmitter for RTD Input Non Explosion Proof Enclosure 7NG3211 ONNOO 105 00 Explosion Proof Enclosure 7NG3211 OBNOO 150 00 Modem for TH200 and SIPROM Software 7NG3190 6KB 293 00 USB Interface for TH100 and TH200 7NG3092 8KU 318 00 Free SIPROM T software download at Siemens com Order on CD P N A5E003545 12 for 8 00 Two Wire Head Mount Bus Protocol Transmitters for Universal Inputs Type B connection head e Fits a Form B connection head Single or dual point trim e Custom characteristics curve for using with non standard sensors e Alarm signal for break on short circuit Standard transmitter wiring diagrams Pro grammable via SIMATIC PDM or aed page HART handheld communicator e Pt100Q RTD thermocouple and mV inputs Input redundancy with second sensor input e Difference and average measurements
15. Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Search www lesman com for G i _ _ ie RE z ea Ordering Instructions Make one selection from each table section at the right A finished catalog number looks like this Specifications Output 4 20 mA Output D A Accuracy 0 025 span Ambient Temperature Limits 40 to 185 F Humidity Limits 5 100 Adjustment Range No zero span limit within range Damping Time Constant Adjustable from 0 102 sec digital dampening Thermocouple Burnout Upscale or downscale with status message Hazardous Conditions STT3000 meets intrinsic safety requirements and explosion proof requirements when mounted inan explosion proof housing for North Ameri can Classifications Class Groups B D Div 1 Complete specs available at Lesman com Input Actuations O e a F Input Type Thermocouples B N Nicrosil Nisil R S T 200 to 1820 0 to 2300 200 to 1000 200 to 1200 200 to 1370 200 to 1300 50 to 1760 250 to 400 O to 1300 392 to 3308 32 to 4146 328 to 1832 328 to 2192 328 to 2498 328 to 2372 58 to 3200 418 to 752 32 to 2372 NiNiMoly RH Radiamatic 420 to 1800 788 to 3272 Resistance Temperature Detectors RTDs Pt100J JIS1604 81 Pt100 IEC 751 Pt200 Pt500 Cu10 Cu25 Ni500 200 to 640 328 to 1184 200 to 850 20 to 250 80 to 150 328 to 1562 4 to 482 112 to 302 Linear Signals 1000 to 1000 m
16. Processors Industrial processors provide local process control configuration and process visualizations Industrial Housing Designed to protect the imager in even the harsh est operating environments for reliable continuous operation LIPS FTI Software Real time thermal analysis software uses the latest advances in image processing and digital communications to provide solutions for a wide range of processes It is capable of monitoring or controlling up to four imagers at full frame rate and transfer data via TCP IP optional OPC server analog signal or alarm output The software automatically stores images and video in the event of an alarm Detector Uncooled amorphous silicon focal plane array Frame Rate 30 frames per second Image Pixels 320 x 240 Focusing Range 4x3 format 32 field of view 19 0 5m to infinity 76 field of view 39 1m to infinity System Measurement Drift with Ambient Temperature 0 2 indicated 1 ambient F or C Protection IP65 NEMA 4 enclosure Vibration 0 5mm 10 60 Hz 3g 60 300 Hz CE Certification EN 61326 1999B Wireless Sensing and Communications Digital Indicators Controllers and Programmers Recorders and Data Acquisition Y o7 7a Sum c o GE we a a JS S D E ES Analytical Instruments and Systems SUOI EDIUNWIWO gt pue Bulsuas Ssejaul sJayqiuusued pue uolsinboy e1eq sx W WLI bOd pue s1 p102 4 s10 221pu je11biq pue s1
17. SS above 1650 F To select a longer or shorter custom sheath length insert the desired length in inches in the three digits before the 012 12 as shown above For lengths over 127 be sure to include the appropriate price adder per 6 additional length There is no price reduction for lengths under 12 12 Length Catalog Number 64 80 Inconel Inconel Inconel Optional Termination Head Materials Available For Optional Head Replace 31 with Add to Price Polypropylene Screw Cover Cast Iron Screw Cover Cast Iron Aluminum Explosion Proof Stainless Steel Head For thermocouple extension wire see page 122 Need a compression fitting Call us Wireless Sensing and Communications Digital Indicators Controllers and Programmers Recorders and Data Acquisition 7a u o7 7a Sum c o GE we a a JS fae ap E Ea Analytical Instruments and Systems e Complete with cast aluminum protection head e Wells available with 1 23 47 and 1 process connections We ve made it easy for you to select thermocouples with matching thermowells It s as easy as 1 2 3 1 Select the process connection well length and material 2 Addthe matching thermocouple just by inserting the thermocouple type desired in place of the SIDUUWWPIBOJd pue SJa JO1 U0D 3 Add the 2 prices and part numbers together and you have a com plete catalog number with pricing Please remember
18. STT25T STT25S STT25D 0 00 No Housing mE Field Mount Housing Exp Proof Aluminum Poly Epoxy Paint Field Mount Housing Exp Proof 316 SS Cable Entry Not Applicable No Housing Supplied 1 2 NPT Cable Conduit Entry Config None Factory Default Supplied uration User Specified Configuration Call Lesman Customer None Tagging 316 SS Wired on I D Tag 4 lines 28 char line English Operator Manual one per five units E None Carbon Steel Mounting Bracket for 2 Pipe Stainless Steel Alala i Bracket for 2 Pipe Lightning None _0 Protection Internal Surge Lightning Protection _S Certificates No Calibration Certificate ooo SIL2 No SIL2 TUV Certification SIL2 TUV Certification STT25S Only Explosion Proof CI I Div 1 Gros A D Dust Ignit Proof CI Il Ill Div 1 Grps E G Intrinsic Safe Cl 1 II Ill Div 1 Grps A G Non Incendive Cl I Div 2 Gros A D Suitable for Cl Il Ill Div 2 Grps F G Explosion Proof CI I Div 1 Gros B D Dust Ignit Proof CI Il Ill Div 1 Grps E G Intrinsic Safe CI 1 II Ill Div 1 Grps A G Non Incendive Cl I Div 2 Gros A D Suitable for Cl Il Ill Div 2 Grps F G Mounting Hardware Restrictions a 20 characters max on nameplate available at no cost d Model number does not appear on module or head mount housing Order wired on tag i Available only on STT25D and STT25M transmitters Illinois Indiana Missouri and lowa
19. Thermocouple Alloy Terminal Blocks O Q Spade Lugs and O 0 Terminal Lugs OC O Standard Size and Mini Jack Panels Thermocouple Element Insulators Call 800 953 7626 Wireless Sensing and Communications Controllers and Programmers Digital Indicators Recorders and Data Acquisition erature Sensors and Transmitters Temp Analytical Instruments and Systems SUOI EDIUNWIWO gt pue Bulsuas Ssejaul SIDUIWIPIBOJd s10 221pu JeIWHIG pue SJa J01 U0D uoisinboy e1eq pue SJapsJODOY dwe je gt OL pa fey gt n 3 c D T SJOSU DINICJO SW S S pue SJUaWUNAYsU Je21 jeuy Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 THERMOCOUPLE amp RTD WIRE amp Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Lesman Instrument Company www lesman com sales lesman com L 22 Thermocouple Wire and Thermocouple RTD Extension Wire Helpful Hints 1 Use thermocouple wire to make thermocouple elements or to connect thermocouples to instrumentation Extension wire should be used only to connect thermocouples to instrumentation Match the wire with the thermocouple to be used 2 Select wire insulation compatible with the application environment For applications requiring moisture resistance use Teflon PVC Kapton and Tefzel For applications requiring hi
20. a multimeter A red green LED shows the technician the status at a glance Additional diagnostic features like a drag indicator and time meter plus output current to be used for simulation TH200 setup is quick and easy with the transmitter modem and SIPROMT software SITRANS TH300 can be con figured with SIMATIC PDM or HART handheld programmer See pages 187 and 188 for configuration tools TEMPERATURE 133 L TRANSMITTER V 02 2011 e Pt100Q RTD thermocouple and mV inputs e TH200 programmable using free SIPROM T Fits a Form B connection head software TH300 programmable via HART and SIMATIC PDM e Temperature compensation via internal reference junction e Universal input DIN rail mount models avail able Prices start at 303 00 e Difference and average measurements e Single or dual point trim Please submit orders to Siemens Industry Inc Model Selection Guide c o Lesman Instrument Company 4 20 mA linear output signal Catalog circuit according to NAMUR 43 a Siemens SITRANS TH200 Universal Input Temperature Transmitter f Galvanic isolation for accuracy and Non Explosion Proof Enclosure 7NG3211 1NNOO 255 00 safety in thermocouple applications FM Approved Explosion Proof Enclosure 7NG3211 1BN00 295 00 e Custom characteristic curve for ap Siemens SITRANS TH300 Universal Temperature Transmitter with HART plication of non standard sensors Non Explosion Proof Enclosure 7NG3212 ONNOO 368 00 ee
21. applications LSP71 Narrow spectral response makes it ideal for process imaging and temperature control of hydrocarbon thin plastics Consistent accurate temperature data is critical inthe thermoforming process to ensure that the finished productis correctly formed Low form ing temperature produces stresses in the formed part and temperatures that are too high can cause blistering and loss of color or gloss The new Landscan control processors include 19 rack mount and the compact wall back of panel mount units all of which provide serial and Ethernet outputs for temperature data All units can interface to local process control systems or Landscan software Address orders to Ametek Land Inc c o Lesman Instrument Company Model LSP60 LSP61 LSP71 LSP62 LSP5FL LSP50 LSP20 LSP21 LSP52 LSP10 212 to 1112 F 68 to 482 F 122 to 752 F 122 to 662 F Range Spectral Response 302 to 1382 F Scan Speed 50 Hz Preset a Lis 50 Hz Preset 20 Hz Preset 50 Hz Preset Adjustable 302 to 1382 F 392 to 572 to 932 to 1112 to 1562 F 1832 F 2012 F 2552 F 10 100 Hz TO 100 He Aajustable SO HZPIESe Adjustable Sw Speed Resolution lt 15 range 5 4 F gt 15 range 2 F lt 1 Indicated 10 ambient 3 6 F 1 8 F lt 2 Indicated 10 ambient 4 5 F 4 5 F 6 3 F 3 6 F lt 1 Indicated 10 ambient 7 2 F 3 6 F lt 1 Ind 10 ambient lt 3 Ind
22. complete order includes the thermometer and a prewired connector cable ordered separately below G 20 Soa S5 3g Sa ox sT 8 A Address orders to Ametek Land Inc Model Selection Guide c o Lesman Instrument Company Catalog Description Number Y on Land SOLOnet Digital Infrared Thermometer with Laser Sighting co o we Wavelength F C A 1 micron 1022 to 3182 550 to 1750 Yu 1 micron ratio 1292 to 3182 700 to 1750 1 6 micron 482 to 2372 250 to 1300 Se 5 micron 392 to 2012 200 to 1100 or Connecting 3m 10 foot Prewired 800858 E i 15m 50 foot Prewired 800859 r 25m 82 foot Prewired Water Cooled Jacket with Air Purge Air Cooled Jacket with Air Purge 800860 800861 800862 Protection Hardware in Air Purge with Mounting Plate 800863 E U Mounting Single Axis Adjustable Mounting Bracket 800707 Eu Dual Axis Adjustable Mounting Bracket 800708 5 Accessories SN W E Webserver Ethernet Interface Unit 800907 a t CAT5 6 Patch Cable 7 SN W E to Switch 203 897 CA Unit focal distance is configured at the factory E Specify 250mm 500mm 1000mm or Infinity e g 800791 250mm ae All models can be reconfigured in the field through adjustable rings without loss of calibration SUOI EDIUNWIWO gt pue Bulsuas Ssejaul SIDUIWPIBOJd S10 221pu JeWbHIG pue SJa O1 U07D uoisinboy e1
23. gauge thermocouple with a 18 316 SS protection tube 3 4 NPT 316 SS Bushing welded 12 from the tip with an adjustable steel mounting flange Protection Tube Tube Catalog X X Length In Size Number Type J Iron Constantan Thermocouple 8 Gauge Element 316 Stainless Steel J8C 8 50 X X 34 316 Stainless Steel J8C 8 75 X X 34 Inconel 601 J8C 7 50 X X 34 Inconel 601 J8C 7 75 X X 34 316 Stainless Steel J11C 8 50 X X 34 316 Stainless Steel J11C 8 75 X X 34 Inconel 601 J11C 7 50 X X 34 Inconel 601 J11C 7 75 X X 34 Type J Iron Constantan Thermocouple 14 Gauge Element 316 Stainless Steel 1 2 J14C 8 50 X X 34 99 50 109 60 119 70 129 80 139 90 Inconel 601 1 2 J14C 7 50 X X 34 132 00 175 10 218 20 261 30 304 40 Type K Chromel Alumel Thermocouple 8 Gauge Element 316 Stainless Steel K8C 8 50 X X 34 316 Stainless Steel K8C 8 75 X X 34 Inconel 601 K8C 7 50 X X 34 236 40 284 00 Inconel 601 K8C 7 75 X X 34 290 90 352 50 Type K Chromel Alumel Thermocouple 11 Gauge Element 316 Stainless Steel 1 2 K11C 8 50 X X 34 316 Stainless Steel 3 4 K11C 8 75 X X 34 Inconel 601 1 2 K11C 7 50 X X 34 230 20 276 30 Inconel 601 3 4 K11C 7 75 X X 34 284 70 344 30 Type K Chromel Alumel Thermocouple 14 Gauge Element 316 Stainless Steel 1 2 K14C 8 50 X X 34 66 40 76 90 87 40 97 90 108 40 Inconel 601 1 2 K14C 7 50 X X 34
24. standard on all units e Web and network ready with optional interface unit e No signal processor unit or special software needed e Rugged aluminum housing IP65 NEMA 4X e Calibrated to ISO 19075 e Two year warranty Four different SOLOnet thermometer models give you the choice of operating wavelength variants laser alignment and measurement ranges from 382 to 3182 F The measurement span can be selected anywhere within the thermometer range with a minimum span of 90 F SOLOnet can be used in stand alone single point or multipoint instal lations with individual remotely adjustable sub temperature ranges current outputs emissivity or non greyness compensation and user defined alarm settings Choice of built in peak picker track and hold or averager signal processing functions ensures accurate measurement in complex processes The optional DIN rail mounted SOLOnet Webserver Ethernet Interface unit provides a wide choice of configuration interconnection system monitoring and maintenance options For ease of configuration live temperature data is displayed on a PC s web browser together with related measurement parameters All parameters are easily adjusted and saved using drop down menus or text boxes Advanced users will benefit from a lower level interface with direct messaging via Ethernet or addressable RS485 If you choose not to purchase the webserver ethernet interface Land Instruments offers a free one time set
25. to 1832 328 to 1832 1 32 to 1472 328 to 2192 191 to 2498 328 to 2498 32 to 2372 328 to 2372 932 to 3200 58 to 3200 148 to 752 418 to 752 IEC 584 ITS 90 Specifications Accuracy Output D A 0 025 of span Cold Junction 0 9 F Digital AmbientTemperature Effect RTDs or Ohms 0 050 of reading in Ohms T Cs or mV 0 080 of reading in mV Output D A 0 045 of span Cold Junction 40 1 rejection Output 4 20 mA or Honeywell digital DE protocol HART and DE available with 4 to 20 mA output Adjustment Range No limits within max range except mini mum span limit of 1 engineering unit Damping Time Constant Adjustable 0 102 sec damping Output Response Time 1 sec to reach 63 of final value with 0 sec damping Output Update Time Approx 0 5 sec Sensor Open Circuit User selectable open circuit burnout detection Upscale or downscale with critical status message Latching or nonlatching sensor burnout action Rejection Mode Common 120 dB 1 million to 1 from 50 Hz to 50 kHz Series 40 dB 100 to 1 for 50 or 60 Hz 0 5 Hz with internal software filter set to local power line frequency RFI Rejection 0 1 of span at 30V m over 20 to 1 000 MHz in metallic housing and with shielded cables Materials TerminalBlock Noryl Module Housing Noryl with met al interior surface Connection Screws Nickel plated brass Approvals The STT250is Intrinsically Safe to CENELEC FM and CSA standards when used
26. with suitable safety barrier The module is Zone 2 and Explosion Proof to CENELEC FM and CSA standards when installed in suitable housing In Explosion Proof Housing See model selection guide Looking for a HART handheld communicator See page 136 Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Honeywell e Reduces maintenance and inventory costs Lesman Instrument Company www lesman com sales lesman com e Instant alarm generation and post read validation ensure security e Failsafe options ensure reliable performance e Optional integral digital indication meter e Compact size for direct head mounting e Available with HART communications protocol Ordering Instructions Make one selection from each table section below A finished catalog number looks like this STT25M _ Model Selection Guide STT250 Smart No Housing DIN Rail or Wall Mounted Temperature Head Mounted to Sensor in Small Housing Transmitter Field Mounted in Explosion Proof Housing CE Approved Remotely from or Directly to Sensor 4 20 mA Output SCT Configurable HART 5 Protocol 4 20 mA Output Hart 5 Protocol Dual Input 4 20 mA Output HART 6 Protocol 4 20 mA Output Digital DE 4 20 mA Output for Digital imeareren Catalog Avail Number ability q 0 00 1 0 00 STT25M STT25H
27. 00 FTI E 801 FTI E 490 Measuring 4 to 250 F 120 to 660 F 300 to 1100 Range 20 to 120 C 50 to 350 C 150 to 600 C Ambient Range 50 to 110 F 40 to 120 F 10 to 45 C 5 to 50 C oa Nominal 8 14 um Nominal 5 um Nominal 3 9 um esponse lt 0 15 F lt 0 08 C 3 F 1 5 C lt 0 3 F lt 0 15 C 1 3 below 300 F Thermal Resolution Measuring Accuracy lt 0 36 F lt 0 2 C 1 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 FTI E Fixed Thermal Imaging Systems FTI E 391 1100 to 2910 F 600 to 1600 C lt 0 54 F lt 0 3 C J THERMAL J IMAGING 127 Fax 262 923 1797 rile he Ametek Land s FTI E process imaging system gives the plant operator a complete thermal view of the process with a display that responds immediately to changes These changes can be used to trigger alarms automatically control other processes and provide quality control data directly to the control room The FTI can be used in all types of applications in the harshest plant conditions operating continuously to provide fast response data It can directly replace portable solutions that provide only a periodic check to monitor availability and free up plant personnel to act on the data rather than capture it FTI E Thermal Imagers Four imagers are available with different temperature ranges and 32 or 16 field of view 4 x 3 format FTI E Control
28. 12 00 4MC R51T185L283 012 00 4MC R51T185L383 012 00 4MC R51T185L483 012 00 4MC R51T185L683 012 00 4MC Catalog Number for 12 Sheath Length R11T185L283 012 00 8HN31 R11T185L383 012 00 8HN31 R11T185L483 012 00 8HN31 R11T185L683 012 00 8HN31 R51T185L283 012 00 8HN31 R51T185L383 012 00 8HN31 R51T185L483 012 00 8HN31 R51T185L683 012 00 8HN31 Optional Termination Head Materials Available Cast Iron Screw Cover 1 2 SS Hex Fitting Stainless Steel Head 1 2 SS Hex Fitting Class B Explosion Proof Head 1 2 SS Hex Fitting Replace Add or For Optional Head 8HN31 with Deduct Aluminum Screw Cover 1 2 Carbon Steel Hex Fitting Polypropylene Screw Cover 1 2 SS Hex Fitting 8 00 Price Each 113 00 113 00 113 00 113 00 Ta RTDs Resistance Temperature Detectors for General Service Price Adder per 6 Sheath Length 1000 RTD Assemblies with 36 Leads Price Adder per 6 Sheath Length 100Q RTD Assemblies with Quick Disconnect Plugs R11T185L283 012 00 4MC R11T185L383 012 00 4MC Price Adder per 6 Sheath Length 100Q RTD Assemblies with Aluminum Termination Heads See Below for Optional Heads Controllers and Wireless Sensing and Programmers Communications Digital Indicators Recorders and Data Acquisition erature Sensors Y VU 7 g0 Sa O 140 Temp Analytical Instruments and Systems SUOI EDIUNWIWO gt pue Bulsuas
29. 3 mA limit Power Supply 10 to 35 VDC polarity protected Adding Head Mounted Transmitter Ambient Temperature 40 to 185 F i i Catalog Construction Polycarbonate housing polyure aE ae thane potting 440 Programmable Temperature Transmitter T 440 100 00 Ingress Protection IP00 IP54 installed in sen 3 Wire Pt100Q RTD alpha 0 00385 ee ae sor head Upscale Burnout 20 5 mA Vibration Protection 4g 2 150 Hz per Signal pownecale Burnout E Si mA E IEC 60 068 2 6 CE EMC Immunity Interference immu Scale Celsius 2 nity and emission per EN 61 326 1 Fahrenheit 0 00 Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 All RTDs are DIN standard with a temperature coef ficient of 0 00385 Temperature limit is 400 F max 0 64 OD 304 35 55 Sanitary Cap Support Tube 3 4 NPT Conduit Connection FDA Compliant White Polypropylene sarew Cover Head Standard Clean In Place CIP RTDs Above All our CIP RTDs exceed the 3A Sanitary Council Standard 09 08 making them perfect for use in dairy and food processing They are available in 0 1 or 0 01 accuracies The polypropylene head is ideal for washdown areas Please allow 5 7 days for delivery 3 4 NPT 16 Amp Cap 316 55 Mini Sanitary CIP RTDs Above These miniature sanitary CIP RTDs come witha 16AmptTriclover cap to fit 1 2 and 3 4 tube size sanitary fittings and meet 3A Sanitary Council St
30. 751 Pt200 DIN IEC751 Pt500 DIN IEC751 Pt100 JIS C 1604 Ni110 Bristol 7NA Ni120 Minco 7 120 Cu10 Minco 16 9 Millivolts 100 to 100mV Q RTD 2 3 or 4 wire 0 to 1000 Q Pt500 B T C and DIN T C Types available on Special Order Model Selection Guide pein a Description Number TouchTemp II HART Temperature Transmitter 2850T 525 00 Options 35mm DIN Rail Mounting Bracket 100665 652 20 00 Need a special thermocouple or RTD for your process J NIST S NIST NIST N BS4937 135 TouchTemp II Programmable Temperature Transmitter Range Limits C 200 850 200 850 200 260 200 650 105 310 80 320 200 260 180 1200 180 1372 200 400 200 1000 0 1767 0 1767 100 1820 0 1200 F 328 1562 328 1562 328 500 328 1202 157 590 112 608 328 500 292 2192 292 2501 328 752 328 1832 32 3212 32 3212 212 3308 32 2192 If you can draw it design it or describe it we can build it See the configuration form at www Lesman com datasheets Wireless Sensing and Communications Digital Indicators Controllers and Programmers Recorders and Data Acquisition 7a e o7 7o Sum Cc wv GE we a a JS L oe oF Ea Analytical Instruments and Systems SUOI EDIUNWIWO gt pue Bulsuas Ssejaul SIBUUWIPIBOJd sJo edIpU jeWbHIG pue SJa JO1 U0D uoisinboy e1eq pue SJapPJODOY duwe pe o ve N at D N
31. J20 3 507 0 34 0 47 0 64 0 39 0 52 0 69 Fair Very Good Very Good Polyvinyl Polyvinyl Polyvinyl Polyvinyl Polyvinyl Polyvinyl Twisted Alum Mylar PVC Polyvinyl 20 to 221 F 20 to 221 F 20 to 221 F 20 to 221 F Excellent Excellent Excellent Excellent J16 5 502 FA J20 5 502 FA J20 5 510 J20 7 502 Special Construction RTD Extension Wire Thermocouple Wire Type K ANSI Color Code Negative Red Positive Yellow Overall Brown Solid Glass Braid Glass Braid Solid Teflon FEP Extruded Teflon FEP Extruded Thermocouple Extension Wire Type KX ANSI Color Code Negative Wire Red Positive Wire Yellow Overall Yellow 16 Solid Polyvinyl Polyvinyl 20 to 221 F Good Excellent K16 5 502 0 97 1 02 20 Solid Polyvinyl Polyvinyl 20 to 221 F Good Excellent K20 5 502 0 48 0 53 1 19 0 44 Thermocouple Extension Wire Type SX and RX ANSI Color Code Negative Wire Red Positive Wire Black Overall Green Standard lengths are 50 100 250 500 and 1000 feet See Lesman for nonstandard length pricing 16 Solid TFE Tape Heavy Glass Braid Up to 550 F Good Good S16 5 157 20 Solid Wire Each Insulation Insulation Temp Outer Catalog Price Type Construction Style Conductor Inner Jacket Outer Jacket Rating Color Code Jacket Number perFt Glass Braid Up to 900 F Fair Good S20 5 304 24 Stranded Silver Plated Copper TFE Teflon FEP Teflon Red Red Wht IA RT24 3 527 0 68 Good Excellen
32. Ssajaul SIDUIWUPIBOJd pue SJa JO1 U07D 10 eD1p uy ezWHIG uoisinboy e1eq pue SJOPJODOY duwe SJO IUWUSURI pue SJOSU DINICJO SWa sKs pue SJUaWUNAYSU Je217 jeuy L 1 16 TEMPERATURE Illinois Indiana Missouri and lowa SENSORS Lesman Instrument Company Wisconsin and Upper Peninsula Michigan Phone 800 953 7626 630 595 8400 www lesman com Phone 800 837 1700 262 923 1790 Fax 630 595 2386 sales lesman com Fax 262 923 1797 RTDs with Threaded Thermowells Features e 3 wire DIN standard 0 00385Q temperature coefficient e For temperatures from 328 to 400 F e Well materials in 304 or 316 stainless steel brass or carbon steel gt 1 4 OD 316 stainless steel sheath pe e Aluminum screw cover head e Accuracy 0 1 Model Selection Guide Well Selection Process Thread 2 1 2 4 6 9 1 2 1 5 1 8 24 Insertion Length J We made it easy for you to select RTDs with threaded thermowells It s as easy as 1 2 3 1 Pick a process thread connection well length and material 2 Add the catalog number for the matching RTD 3 Add the prices and part numbers together to get your complete catalog number with pricing RTD Selection Material and Price Catalog Brass Steel 304 SS 316 SS Catalog Price Number Number R11T185L483 02 5 SL 8HN31 R11T185L483 004 SL 8HN31 185 U4 1 2 d R1T185L483 006 SL 8HN31 185 U7 1 2
33. V 0 to 2000 Q Lesman Instrument Company www lesman com sales lesman com TEMPERATURE TRANSMITTERS Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 131 L V 02 2011 STT350 Smart Temperature Transmitter Features e Wide variety of accepted inputs reduces transmitter inventory e Standard digital cold junction compensation provides accurate and reli pe able temperature measurement over a wide ambient range f e Smart features include reading of high low inputs external cold junction compensation temperature and choice of engineering units displayed e Smart transmitter with local or remote interfacing means significant man power efficiency in commissioning startup and ongoing maintenance e Suitable for true 2 3 or 4 wire Pt100 measurement e Write protect link safeguards configuration settings e Includes sensor break detection on all input wires Model Selection Guide Catalog Number STT350 Temperature Transmitter Module 4 20 mA DE STT350 FM Intrinsically Safe for Class Il Ill Div 1 Gr A G Non Incendive for Class I Div 2 Gr A D Intrinsically Safe for Class Il Ill Div 1 Gr A G Intrinsically Safe for EEX ia IIC T4 T5 T6 All models comply with EN 50081 2 and 50082 2 No explosion proof housing supplied Explosion prf housing baked on polyester Epoxy paint No meter supplied Integrally housed smart meter S900 model _
34. able if you are sensing temperatures above 1650 F For more information just give us a call we can make just about anything you can describe Well Selection Thermocouple Selection Insertion Material and Price Steel 304 SS 316 SS Catalog Number 48U 02 5 SL 6HN31 48U 004 SL 6HN31 48U 006 SL 6HN31 48U 009 SL 6HN31 48U 012 SL 6HN31 48U 015 SL 6HN31 48U 018 SL 6HN31 48U 024 SL 6HN31 48U 02 5 SL 6HN31 48U 004 SL 6HN31 48U 006 SL 6HN31 48U 009 SL 6HN31 48U 012 SL 6HN31 48U 015 SL 6HN31 48U 018 SL 6HN31 48U 024 SL 6HN31 48U 02 5 SL 6HN31 48U 004 SL 6HN31 48U 006 SL 6HN31 48U 009 SL 6HN31 48U 012 SL 6HN31 48U 015 SL 6HN31 48U 018 SL 6HN31 48U 024 SL 6HN31 Optional Termination Head Materials Available Replace Add to For Optional Head 31 with Price Delrin Screw Cover Cast Iron Screw Cover Cast Iron Aluminum Explosion Proof Stainless Steel Head For information on thermocouple initial material tolerances and thermocouple type color codes see page 489 Illinois Indiana Missouri and lowa Lesman Instrument Company Protection Tube Thermocouple Assemblies The straight base assemblies shown on All assemblies on this page include our this page are those most commonly used standard cast iron screw cover head with Other combinations are available by call terminal block ing Lesman Model Selection Guide Make one selection from each table section Example J11C 8 50 18 H 8D12 is a Type J11
35. ae ion 409 e ATEX cFMus intrinsically safe non MA pproved Exp rer TE a odem for an oftware ICS HSS MOUS EVAR USB Interface for TH100 and TH200 7NG3092 8KU e 8 35 VDC power supply 30V for Ex USB HART Modem for TH300 7MF4997 1DB Four Wire DIN Rail Mount Transmitter for Universal Inputs SITRANS TW is the latest in development of the proven DIN rail mounted SITRANS T four wire system Its diagnostic and simulation functions provide the necessary clarity during commissioning and operation Its HART interface makes the SITRANS TW easily adaptable to any measuring job with SIMATIC PDM Physical values can be preset with the simulation function This enables testing of the complete signal path right as far as the control system without the need for tools The drag pointer functions measure the system s process variable minimum and maximum All SITRANS TW control room devices are available in non intrinsically safe versions or intrinsically safe versions for applications under extreme conditions e Transmitter in four wire system with HART e 4 20 mA 0 20 mA 0 10V or 2 10V output communications interface Can be mounted on 35mm or 32mm G DIN rail Internal temperature compensation ATEX EEx ia or EEX ib explosion protection for e 115 230 VAC or 24 VDC power supply measurements with sensors in hazardous areas e Configurable via SIMATIC PDM software e Monitors sensor and cable for open and short circuits All circ
36. an dard 09 08 Please allow 3 weeks for delivery Express delivery 3 5 days is available Call for details Fast Response RTDs for HTST Applications At Right When an RTD is used in a HTST High Temperature Short Time application the FDA re quires it to respond in less than 4 seconds So our HTST fast response RTD is perfect it meets 3A and the FDA time requirements The polypropylene head is great for washdown areas and includes wire seal security screws Please allow 5 7 days for delivery Lesman Instrument Company www lesman com sales lesman com Length 4 4 4 4 5 5 5 5 5 5 6 6 6 6 6 6 6 6 Immersion Length 2 Length Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Cap Size and Type 1 1 2 Triclover 16 AMP 1 1 2 Triclover 16 AMP 2 Triclover 16 AMP 2 Triclover 16 AMP 1 1 2 Triclover 16 AMP 1 1 2 Triclover 16 AMP 2 Triclover 16 AMP 2 Triclover 16 AMP 2 1 2 Triclover 16 AMP 2 1 2 Triclover 16 AMP 1 1 2 Triclover 16 AMP 1 1 2 Triclover 16 AMP 2 Triclover 16 AMP 2 Triclover 16 AMP 2 1 2 Triclover 16 AMP 2 1 2 Triclover 16 AMP 3 Triclover 16 AMP 3 Triclover 16 AMP Cap Size and Type 1 2 Triclover 16 AMP 1 2 Triclover 16 AMP 3 4 Triclover 16 AMP 3 4 Triclover 16 AMP 1 2 Triclover 16 AMP 1 2 Triclover 16 AMP 3 4 Triclover 16 AMP 3 4 Triclover 16 AMP Highl
37. and tactile keypad simultaneous display of up to four different thermometers at once e Two high low alarms for use in On Off control e Unique multichannel and math function options e Oto 20mA 4 to 20mA and 1mV outputs to suit any control system e RS232C and RS485 serial communications option Two Landmark Graphic processors are available a single thermometer version and a multichannel version that can be configured to work with up to four different System 4 thermometers simultaneously and can apply user configured math functions to the thermometers measure ment signals The processor supplies power to each thermometer and the control signals required for either emissivity or non greyness compensation A large LCD display shows temperature and parameter variables and system outputs Landmark Graphic Multichannel Capability The multichannel Landmark Graphic processor provides up to four fully featured independent measurement systems in one package Any System 4 thermometer can be connected to any input channel of the processor Each channel is fully independent of the other the inputs are not multiplexed Additional channels may be added as required without affecting existing settings The processor can control all types of thermometers simultaneously The thermometers can have different temperature ranges and units C or F Each channel has identical features to the single channel version and two fully scalable analo
38. andheld Communicator 3302 00 136 To Pyromation Plugs and Jacks 4 70 122 So Pyromation Thermocouple Accessories Call 121 Pyromation Thermocouple Wire and Sensor Extension Wire Call 122 SUOI EDIUNWIWO gt pue Bulsuas Ssajoul SIDUIWIPIBOJd S10 221pu JeWbHIG pue SJa J01 U0D uoisinboy e1eq pue SJOPJODIOY pe o pe 7 3 at D 7 SIOSUSS DIN eJOdWa SWa sKs pue SJUaWUNAYsSU edIA eEUY TEMPERATURE SENSORS Temperature Assemb Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 lies Lesman Instrument Company www lesman com sales lesman com Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Build Your Own Temperature Assemblies with the UE Sensor Box Ordering Instructions Have your plant back up in minutes not days United Electric s Sensor Box is designed for maintenance and instrument technicians in any plant where temperature sensors are an important part of the operation and down time is not an option Looking for wells Don t see the part you need Call Lesman The basic Sensor Box includes toolbox tools parts and any combination of up to six sensors Ordering Example EK1000 with 3 RT1260 2 MI1113JG and 1 MI1113KG sensor pods Model Selection Guide Catalog Description Number Basic UE Sensor Box complete with toolbox tools an
39. anumeric keypad with menu shortcuts for frequently used commands dedicated text edit keys HART menu Home key and left side thumb keys for easy one handed navigation Update firmware and device files for up to 420 HART devices from Meriam s website Catalog Number Price Communicator with 3 Year Device File Download Website Subscription General Service HART Communicator MFC4150 01 3847 00 Intrinsically Safe HART Communicator MFC4150X 01 4046 00 Communicator No Download Subscription General Service HART Communicator MFC4150 00 3302 00 Intrinsically Safe HART Communicator MFC4150X 00 3501 00 PHCENIX CONTACT INNOVATION IN INTERFACE Slim power supply for use in performance class up to 100W The consistent provision of a input of 85 264 VAC or 90 350 VDC an integrated power reserve POWER BOOST ensures safe operation in AC and DC networks Specifications Input voltage 85 264 VAC 90 VDC 350 VDC Output voltage 24 V Signal Range 22 5 28 5 VDC gt 24 V constant capacity Nominal voltage nput 100 240 VAC Output 24 V 1 Continuous current Max 20 mA Output current 1A Up to 60 C 1 3A With POWER BOOST Frequency range 45 Hz 65 Hz 0 Hz with DC input Inrush surge current lt 15 A Typical Input fuse 1 25 A Slow blow internal Maximum power dissipation idling 1 W Power loss nominal load max 4 5 W MTBF gt 500 000 hr in accordance with IEC 1709 SN 29 500 Mini Powe
40. ce wiring costs These transmitters automatically linearize the temperature output signal bounded by the user s upper and lower range values STT170 models can also be programmed with high or low limit alarms that activate on sensor failure Once it s installed on a PC the graphical interface of the STT17C software configuration tool virtually eliminates the need for operator training The STT17C configuration toolkit contains all the software and transmitter interface hardware necessary to configure the ST1171 ST1T173 and STT17H in non hazardous work environments If you don t want to configure the transmitters yourself you can order them factory configured Contact Lesman for the custom configuration datasheets Condensed Specifications Ambient Operating Temperature 40 to 185 F 40 to 85 C Humidity 0 to 95 rH non condensing Operating 5 to 100 Alarm Levels Programmable 3 5 4 mA downscale 20 23 mA upscale VAMUR NE43 Upscale 23 mA NAMUR NE43 Downscale 3 5 mA Approvals FM CSA ATEX Intrinsically Safe Non Incendive Class Div 1 Groups A D T4 Class 1 Zone 0 1 AEx ia IIC T4 Class Div 2 Groups A D T4 Intrinsically Safe Non Incendive Class Div 2 Groups A D T4 Class Zone 0 1 Ex ia IIC T4 Class 1 Div 2 Groups A D T4 Intrinsically Safe Zone 0 1 Ex Il 1 GD EEx ia IIC T4 T6 Ex Il 2 1 GD T4 T6 when mounted in a Form B metal head mount enclosure per DIN 43729 that provides a degree o
41. couple Suggested Type Range K48 012 00 15HT T1036 2 Type E Chromel Constantan Thermocouple E18 012 00 15HT T1036 2 E28 012 00 15HT T1036 2 E38 012 00 15HT T1036 2 E48 012 00 15HT T1036 2 Type T Copper Constantan Thermocouple 1 16 T18 012 00 15HT T1036 2 1 8 T28 012 00 15HT T1036 2 3 16 T38 012 00 15HT T1036 2 1 4 T48 012 00 15HT T1036 2 Please specify junction type G Grounded E Exposed U Ungrounded Insert the correct letter designa tion in place of the for a complete catalog number 32 to 1400 F K 32 to 2300 F E 32 to 1600 F T 300 to 700 F Do not use 316 SS above 1700 F Max temp varies by sheath diameter Transition Fittings Note For use at tempera tures above 500 F please specify fiberglass wire 11__ _ for temps to 900 F 21__ _ for To select a longer or shorter custom sheath length insert the desired length in inches in the three digits temps to 1300 F Types J K only before the 012 12 as shown above For lengths over 127 be sure to include the appropriate price adder per 6 additional length There is no price reduction for lengths under 12 For longer lead lengths insert the desired length in inches in the three digits near the end of the catalog number 036 36 as shown above For each additional 12 length add 1 00 to the price Need compression fittings plugs or other accessories Call Lesman Thermocou
42. d parts listed below EK1000 Sensor Parts in Toolbox Sensors 6 Total Mix and match as needed Optional Components Housing 0 250 OD x 24 long 316 stainless steel NEMA 4 Aluminum terminal head 4 post ceramic block Spring loading kit for AC1054 head Nipple 1 2 NPT x 2 long carbon steel Union 1 2 NPT carbon steel for NEMA 4 applications Wire guide Bag of 10 695 00 Crimper tube cutter screwdriver tape measure wire stripper Pt100Q RTD 3 wire Teflon insulation max temp 400 F Pt100Q RTD 3 wire fiberglass insulation max temp 900 F Thermocouple with ungrounded junction fiberglass leads Thermocouple with grounded junction fiberglass leads Thermocouple with ungrounded junction Teflon leads Thermocouple with grounded junction Teflon leads 316 stainless steel housing 0 250 OD x 12 long 2 long carbon steel nipple 1 2 NPT 2 long stainless steel nipple 1 2 NPT 1 2 NPT union carbon steel for NEMA 4 1 2 NPT union stainless steel for NEMA 4 Plastic wire bushing pack of 10 RT1260 RT1254 MlI1113_U MI1113_G MI1113TF_U MI1113TF_G HS2512 NC1002 NS1002 UC1011 HF1091 TS1092 Specify calibration J K T or E e g Ml1113KU Dual calibration pods are available at a slightly higher cost Please indicate as KK EE JJ or TT Pods with fiberglass leads are rated to 900 F those with Teflon leads are rated to 400 F For higher tem
43. e appropriate price adder per 6 additional length There is no price reduction for lengths under 12 For details on thermocouple initial material tolerances and thermocouple type color codes see page 489 MgO Insulated Thermocouples Features e Use with compression fittings e 1 2 NPT process and conduit connections e Inconel or 316 stainless steel sheath Inconel good to 2100 F Varies by sheath diameter If you need a dual element or different sheath material give us a call We have most materials available Please remember that when wiring thermocouples red is always negative Model Selection Guide Price Adder Each 6 Grounded Un Type J Iron Constantan Thermocouple 32 to 1400 F J28 012 00 8HN31 61 80 J38 012 00 8HN31 64 00 67 00 J48 012 00 8HN31 68 40 71 40 Type K Chromel Alumel Thermocouple 32 to 2300 F K23 012 00 8HN31 64 60 67 60 68 70 71 70 75 80 78 50 61 80 64 80 64 00 67 00 K48 012 00 8HN31 68 40 71 40 Type E Chromel Constantan Thermocouple 32 to 1600 F E28 012 00 8HN31 63 20 66 20 E38 012 00 8HN31 65 80 68 80 E48 012 00 8HN31 69 40 72 40 Type T Copper Constantan Thermocouple 300 to 700 F T28 012 00 8HN31 62 70 65 70 T38 012 00 8HN31 65 80 68 80 T48 012 00 8HN31 70 90 73 90 Please specify junction type G Grounded E Exposed U Ungrounded Insert the correct letter designation in place of the Do not use 316
44. endive Controllers and Wireless Sensing and Programmers Communications Digital Indicators Recorders and Data Acquisition erature Sensors a VU 74 g0 Sa O 140 Temp Analytical Instruments and Systems SUOI EDIUNWIWO gt pue Bulsuas Ssejaul SIDUIWUPIBOJd s1OJedIPU JeWHIG pue SJa JO1 U07D uoisinboy e1eq pue SJOPJODOY pe oO pe N 3 at D N SIOSUSS JINJeJOdWa SWa sKs pue SJUaWUNAYsSU edIA EUY TEMPERATURE TRANSMITTER amp Fax 630 595 2386 IL 132 Siemens SITRANS TH compact head mount transmitter is designed to fit in Form B connection heads even in the flat cover version installed in place of aterminal block Features include galvanic isolation to 500 VAC Ex approval and ruggedness at temperatures ranging from 40 to 185 F The basic TH100 is a straightforward compact transmitter for RTD inputs With measuring technology that s universal and accurate the PC programmableTH200 and HART programmableTH300 offer versatile diagnostics and simulation options in a service friendly package The operating status of these units can be seen at a glance thanks to a pair of colored LEDs All your technician needs to do is connect an ammeter to the test sockets and read the output current without opening the measuring circuit The TH400 is designed for Profibus PA and Foundation Fieldbus instal lations TH400
45. eq pue SJaPJODOY pe oO pe N 3 at D 7 SIOSUSS JIN eJodwa SWa sKs pue SJUaWUNAYsSU edIA EUY L 124 INFRARED THERMOMETRY X Fax 630 595 2386 Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Lesman Instrument Company www lesman com sales lesman com System 4 for Advanced Infrared Radiation Thermometry System 4 non contact temperature measuring systems are designed for continuous quality and process monitoring and control in a wide range of applications metal production processing foundry and forging glass electronics mineral processing and petrochemical where accurate measurement of temperature is vital No other method of temperature measurement offers the benefits of non contact infrared radiation thermometry Infrared thermometer systems continuously measure the temperature of hot moving or inaccessible materials ac curately and from a safe distance e Sensing heads do not require contact with the target object so they can t interfere with damage or contaminate the product they are measuring e Thermometers don t remove heat or disturb the process being monitored and offer the only solution when the product is small fragile or in a vacuum or controlled atmosphere Thermometers Infrared radiation thermometers do not r
46. equire contact with the target object so they cannotinterfere with damage or contaminate the product they are measuring They do not remove heat or disturb the process be ing monitored and offer the only solution when the product is moving small fragile or in a vacuum or controlled atmosphere System 4 thermometers all feature temperature spans and operating wavebands selected to ensure optimum accuracy of measurement for each application Any System 4 thermometer can be used with any System 4Landmark processor allowing you to build a temperature measurement system designed specifically to your application e Focusable optics guaranteeing a minimum of 98 of target energy within the lens graticule e Additional close up lenses for standard bodied thermometers for targets as small as 0 45mm 0 020 in e Flexible fiberoptics light guide versions with optional laser target ing system to define target size and position e Traceable individual calibration giving flexible systems with unrestricted interchangeability e Long term accurate reliable and drift free measurement e Rugged design with a wide range of mounting accessories Standard thermometers feature precision through the lens focusable optics that guarantee exact viewing and accurate measurement of the smallest of target areas Single wavelength thermometers are intended for general purpose use as well as solving problems in specific applications Fiberoptic ther mom
47. eters are used to measure the temperature of materials where the targetis difficult to access and where high temperature or high magnetic fields prevent the use of other types of sensors Landmark Technic signal processor with s a System 4 infrared permoni i a 7 i ie ar Ratio thermometers are used in difficult environments containing steam smoke or dust or where the target is small or does not completely fill the field of view Proven reliable electronics anda high quality optical system are housed in a rugged diecast aluminum body with a robust electrical connector to provide reliable performance All thermometers feature through the lens sighting Adjustable focus with a circular graticule gives precise align ment on to the smallest of targets Two optical variants are available standard and short focus M1 thermometers For general purpose use in high temperature ap plications from 1850 to 4700 F 450 to 2600 C They use a silicon cell detector operate at short wavelengths and have a fast response time of 5ms to 95 M2 thermometers Range to 600 F 300 C with a fast response time of 5ms M2s operate at a wavelength of 1 6 vm using latest generation of germanium detectors M4 thermometers Measure from 150 to 1000 F 50 to 550 C Used on low temperature low or uncertain emissivity surfaces such as bright or un oxidized metals They use lead sulfide detectors ina unique null balance mode to guara
48. f protection of at least IP6X in accordance with EN 60529 that is suitable for the application and correctly installed DEE Visit our website for complete specifications and manuals Non Incendive Zone 2 Class Div 2 Groups A D T4 Ex II 3 G EEx nA L T4 T6 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 TEMPERATURE TRANSMITTERS V 02 2011 Fax 262 923 1797 STT173 Features e Analog 4 20 mA output e RTD thermocouple Ohm or mV input DIN Form B head mount i NAMUR NE43 sensor error response Galvanic isolation e Configurable using STT17C configuration tool and PC STT17F Features e FOUNDATION fieldbus protocol FISCO certified RTD thermocouple Ohm or mV input e Single or dual difference or average sensor input DIN Form B head mount e Two analog and one PID function block e Basic or LAS capability e Galvanic isolation Search www lesman com nig Honeywell STT170 e Configurable using Experion and field communicator System requirements Windows 98SE ME 2000 a or XP witha minimum of 16MB RAM 12MB hard disk space and video resolution of 800x600 biar Lee tae hide Eem iee aj I fae zem mai ia hat Ordering Instructions Make one selection from each table section Check the availability column to be sure that the unit you need is available A finished catalog number looks like this STT17_ __ _ Model Selection Gu
49. features include programmable sensor limit values failure behavior and galvanic isolation plus sensor redundancy when installed with two input sensors TH100 and TH200 transmitters can be configured using a special modem and PC based SIPROM T software The HART enabled TH300 offers user friendly operation using Siemens SIMATIC PDM or a HART communicator PDM is the configuration tool of choice forTH400 Profibus Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Lesman Instrument Company www lesman com sales lesman com ITRANS T Temperature Transmitters At a Glance Diagnostics Solid Red Check Transmitter Solid Green Status OK Blinking Red Check Measurement PA models The TH400 Foundation Fieldbus model requires use of an FF communicator or AMS software SITRANSTW rail mount transmitters are great for control room applica tions They feature an auxiliary power connection for great flexibility and a relay output TW transmitters can be configured for 4 20 mA output 0 20 mA and 0 10 or 2 10 VDC via HART protocol The transmitter can be operated via SIMATIC PDM or a HART handheld communicator Two Wire Head Mount Transmitter for RTDs e Fits a Form B connection head Configure using modem and free SIPROM T software e ATEX cFMus intrinsically safe non incendive model available e
50. for applications where you need to easily disconnect the ther mocouple from the leadwires You can also attach any length leadwire you want just by ordering your desired length of thermocouple exten sion wire Need a dual element of different sheath material Give us a call We can get just about anything you can describe Model Selection Guide Price Adder Grounded Un per 6 Exposed grounded Length Type J Iron Constantan Thermocouple J18 012 00 04 J28 012 00 04 J38 012 00 04 J48 012 00 04 Type K Chromel Alumel Thermocouple K23 012 00 04 K33 00 04 K43 00 04 K18 012 00 04 12 Length Catalog Number Inconel Inconel 012 Inconel 012 1 16 2 1 8 K28 012 00 04 3 16 K38 012 00 04 1 4 K48 012 00 04 Type E Chromel Constantan Thermocouple 1 16 E18 012 00 04 1 8 E28 012 00 04 3 16 E38 012 00 04 1 4 E48 012 00 04 Type T Copper Constantan Thermocouple 1 16 T18 012 00 04 T28 012 00 04 T38 012 00 04 T48 012 00 04 1 8 3 16 1 4 Please specify junction type G Grounded E Exposed U Ungrounded Insertthe correct letter designation in place of the for a complete catalog number To select a longer or shorter custom sheath length insert the desired length in inches in the three digits before the 012 12 as shown above For lengths over 12 include th
51. ftware CD Modem for TH200 and SIPROM Software USB HART Coupler for SIMATIC PDM SIPROM RS 232 HART Modem for SIMATIC PDM SIPROM A5E00354512 7NG3190 6KB 7MF4997 1DB 7MF4997 1DA FM approval includes explosion proof dust ignition proof non incendive and intrinsically safe ratings Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 me ipi r gransM ATION Specifications Lesman Instrument Company www lesman com sales lesman com Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 V 02 2011 Universal Temperature Transmitter 8 thermocouples 6 RTD types millivolts and ohms Two Button Programming No jumpers dipswitches or communicators required Integral Full Five Digit Display Displays process inputs engineering units plus warn ing and programming prompts with 0 1 resolution Complete Diagnostics Checks for reference voltage cold junction EEPROM and CPU errors Also indicates under or over range and open input conditions 0 05 Digital Accuracy Field Tough Standard features include isolation RFI protection and outstanding accuracy over the widest ambient range 40 to 185 F HART Communications Model Available Input Actuations TEMPERATURE TRANSMITTERS Input Span Limits Any span within range limits Input Resolution Temperature 0 1 mV 1 uv Ohms 0 019 Maximum Output Range
52. g outputs Two alarm outputs both either Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 INFRARED THERMOMETR V 02 2011 Fax 262 923 1797 Two independent math functions can be specified on the System 4 Landmark Graphic processor High or Low activated each with the changeover relay are provided on every channel card Math Functions Two independent math functions are provided with the Landmark Graphic Each can calculate display and output either the maximum minimum mean difference or range of temperatures measured Each math function is fully independent of the other and both are independent from the four individual thermometer temperature output channels Each function has both a current output either 0 to 20 mA or 4 to 20mA and a single relay alarm output The expanded span function allows you to extend the span of your temperature measurement system from the minimum temperature of the thermometer with the lowest range to the maximum temperature of the thermometer with the highest range Easy Configuration Landmark Graphicis easy to configure using the text based setup menu system Once the thermometer type has been entered the processor automatically configures the appropriate input data You can then select the required temperature span for the output current range target emissivity non grayness values and a range of time functions and alarm settings to match your exact need
53. gh temperature insulations use fiber glass Vitreous Silica and ceramic fiber 3 Use stranded conductor wire to connect thermocouples where continuous or frequent flexing of the leadwire occurs 4 Use metal overbraids and leads in flexible armor to provide protection against physical abuse to wiring 5 Use leadwire with aluminum Mylar shields and drain wires to connect sensors to computers and protect against EMF stray signals 6 Do not run thermocouple leads in conduits that carry power wiring Do not run conduit carrying thermocouple leads parallel to electric buss bars or heavy power carrying conduits Cross them at right angles 7 Whenconnecting these wires to instrumentation red is always negative The other color coded wire is always positive We reserve the right to ship 10 of the length ordered unless an exact requirement is clearly specified on the order Thermocouple Wire and Thermocouple Extension Wire Wire Gauge Wire Type Each Conductor Exterior Cover Continuous Standard lengths are 50 100 250 500 and 1000 feet Price per Foot Moisture Non Std Resistance Length Abrasion Resistance Temp Rating Catalog Number Thermocouple Wire Type J ANSI Color Code Negative Wire Red Positive Wire White Overall Brown Glass Braid Teflon FEP Extruded Teflon FEP Extruded Glass Braid Teflon FEP Extruded Teflon FEP Extruded Good Excellent Excellent J20 1 304 J20 1 507
54. ide 4 20 mA Output RTD Input 4 20 mA Output Universal Input HART Protocol 4 20 mA Output Foundation Fieldbus Protocol Digital Output STT17F FM CSA ATEX Intrinsically Safe BS FM CSA ATEX Non Incendive ae the Sensor Nomepolseserrose o FEF Config Factory Default Configuration Saag 1 115 00 225 00 415 00 Approvals uration Custom Configuration Custom Calibration Documen None tation Cert of Conformance Origin Configuration Tool STT171 173 17H STT17C 00 0 000 DIN Rail Clip 50017850 001 Includes Printed Configuration or Calibration Report Wireless Sensing and Communications Controllers and Programmers Recorders and Digital Indicators and Transmitters Data Acquisition Temperature Sensors Analytical Instruments and Systems SUOI EDIUNWIWO gt pue Bbulsuas ssajaul SIDUUWIPIBOJd s10 221pu JeWHIG pue SJa JO1 U0D uonisinboy eeq pue SsJ p102 4 4 dwe pe oO pe 5 N 3 at D N SJOSU DINICJO SW S S pue SJUaWUNAYSU Je217 jeuy TEMPERATURE TRANSMITTER I PRED STT250 Smart Temperature Transmitter Input Actuations a or Dio a l a Over Range Pt100 IEC751 1986 328 to 842 328 to 1562 PA Pt200 a 0 00385 328 to 8 rue 328 to 1562 0 72 42 Pt100J JISC1604 81 a 0 00392 328 to 842 328 to 1184 0 45 0 to 2000Q 0 to 20000 0 400 20 to 120mV se 20 to 120mV 15mV 1022 to 3308 392 to 3308 32
55. istance Temperature Detectors RTDs E Pyromation 3A Sanitary RTDs for the Food Industry 117 00 117 E Pyromation RTDs for General Service 72 35 115 2 Pyromation RTDs with Threaded Thermowells 116 00 116 United Electric Heat Trace RTDs with Replaceable Sensors 115 00 114 United Electric Sensor Box Temperature Assembly Kit 695 00 114 Temperature Transmitters ZS Honeywell STT170 Programmable Temperature Transmitters 115 00 129 ve Honeywell STT250 Smart Temperature Transmitter 480 00 130 l Honeywell STT350 Smart Temperature Transmitter with Digital Display 892 00 131 S Pyragon TouchTemp II Programmable Temperature Transmitter 395 00 135 aS Pyromation Transmitter Assemblies for Field Mount RTDs 100 00 116 Pyromation Mini Transmitter Assemblies for Small Spaces 105 00 117 Siemens SITRANS T Head Mount Temperature Transmitters 105 00 132 p Siemens SITRANS TF Field Mount Temperature Transmitters 423 00 134 O 7 TE Thermocouples vE Pyromation Industrial Thermocouples with Termination Heads 61 80 119 2 Pyromation Metal Protection Tube Thermocouple Assemblies 66 40 121 tes Pyromation Thermocouple Assemblies for General Service 31 60 118 5 i Pyromation Thermocouple Assemblies with Quick Disconnect Plugs 18 40 119 Pyromation Thermocouples with Matching Thermowells 66 40 120 United Electric Sensor Box Temperature Assembly Kit 695 00 114 2 VU Parts and Accessories gt DIN Rail Mountable DC Power Supplies 60 00 136 2 D Meriam MFC4150 HART H
56. ker averager track and hold alarm and 4 to 20mA outputs and RS232C serial communications for setup via a PC Standard DIN rail mounting requires no panel space Standard time functions average peak picker and track and hold 4to 20 mA output and alarm output e Remote input for Track and Hold e Emissivity non greyness adjustment Setup performed using a PC and configuration software e Indicator LMi and power supply are also available RS232C serial communications provide a remote interface between the processor and a PC for configuring the system parameters Landmark GRAPHIC is the state of the art panel mounted signal processor designed to control and process data from any System 4 Thermometer The multichannel processor accepts processes and simul taneously displays inputs from any combination of up to four separate thermometers Multiple outputs can be integrated directly into any process monitoring recording or control system Landmark Graphic processors offer a variety of features and advanced time functions that present temperature data in a choice of displays and outputs to suit the particular application They re rugged and extremely versatile giving you more choice and more precision e Highest system accuracy e Real time signal processing peak picker averager with selectable time constant and track hold functions e User friendly backlit LCD interface with large numeric and graphic displays
57. ltichannel digital analog inputs and outputs e Wide range of protection and mounting accessories Ametek Land s Landscan LSP high speed wide angle infrared linescan ning systems are designed for accurate process imaging and temperature measurement in a wide range of applications from 68 to 2552 F The LSP series linescanner head is extremely compact witha minimized depth and base footprint for installation in restricted spaces designed to reduce heat absorption A built in laser targeting system aids in target alignment LSP systems have extensive storage display and analysis capabilities processing temperature data from multiple sensor heads and database and archive files simultaneously LSP5 For forming annealing and tempering LSP5FL is ideal for use in the hostile environment of the float glass line and is available with dedicated rugged protection mounting and assemblies Linescanner Model Specifications Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Lesman Instrument Company www lesman com sales lesman com AMETEK LAND This just in LSP HD line scanner Up to 1000 samples per scan line anda faster scan rate Standard with Ethernet connectivity in the scanner head and Power over Ethernet IEEE 802 3at LSP6 Low temperature linescanners for process imaging and control
58. mitter FM approved units available IP 68 rating Field transmitter with LCD and integrated sensor Stainless steel thermowell Programmable via three front face keys Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Lesman Instrument Company www lesman com sales lesman com T C B E J K L N R S T U W3 W5 Linear signals Q mV RTD Pt100 Pt1000 Ni100 Varies by Model T C B E J K N R S T RTD Pt100 Pt200 Pt500 Ni Cu Linear input 100 to 100 mV 0 to 1000Q T C B E J K N R S T RTD Pt100 Pt100J Pt200 Linear signals Q mV T C B C D E J K N R S T NiNi Moly RH Radiamatic RTD Pt100 100J 200 500 Cu10 or 25 Ni500 Linear signals Q mV RTD Pt100 2 3 4 wire RTDs Ohms T C B C D E J K L N R S T U Linear signals mV 2 3 4 wire RTDs Ohms T C B C D E J K L N R S T U Linear signals mV 2 3 4 wire RTDs Ohms T C B E J K N R S T L U W3 W5 Linear signals mV RTD 2 3 or 4 wire Pt25 to Pt1000 Ni25 to Ni1000 Cu25 to Cu1000 T C B E J K R S 1 L U N C and D Linear 1100mV RTD Pt100 4 to 20 mA HART Foundation Fieldbus 4 20 mA HART or digital DE 4 20 mA digital DE 4 20 mA 4 20 mA Profibus PA or Foundation Fieldbus 4 20 mA Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 T C
59. ntee stability M5 thermometers Fast response speed small target size and accurate sighting make the M5 thermometers ideal for all flat glass glass toughening and optical fiber applications M6 thermometers Short wavelength thermometers that measure from 50 to 1300 F 0 to 700 C Designed specifically for lower temperature applications metal processing glass lehr food paper rubber and textiles M7 thermometers Measure from 75 to 700 F 25 to 375 C operating at a waveband selected especially for measurement on plastic films as thin as 20 microns 1 mil M8 thermometers Measure from 30 to 1830 F 0 to 1000 C Ideal for food textiles paper and plastics applications R1 ratio thermometers Measuring range is 1100 to 4700 F 600 to 2600 C For difficult high temperature applications where the field of view is not fully filled or where the sight path is obscured Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales lesman com System 4 Landmark Processors A Landmark signal processor panel or DIN rail mounted uses high speed inputs real time signal processing and flexible outputs to convert the output of each sensor into real process variables Landmark TECHNIC is a high precision DIN rail mounted intelligent digital processor Its features include adjustable emissivity non greyness peak pic
60. output 7NG3140 446 00 SITRANS TF2 Bottom Mounting Type A 1 2 NPT Display Position Back Mounting Type B 1 2 NPT 172 14 NPT Thermowell 4 5 114 mm Length 3 8 00 4 8 00 B 00 K 0 00 P 4 00 0 00 7 5 190 mm Thermowell Stainless Steel z TF Field Mount Transmitter for Harsh Environments Features e 4 20 mA output SIPROM T Specifications Enclosure NEMA 4X Die cast aluminum polyester based lacquer stainless steel rating plate Electrical sensor connection Screw terminals cable inlet via 2 14 NPT threaded gland FM Approval Explosion Proof Div 1 Class 1 Groups B D Dust Ignition Proof Div Il Ill Class 1 Groups E G Non Incendive Div 1 Class 2 Groups A D Intrinsically Safe Div Il Ill Class 2 Groups F G Measured Digital Range Accuracy Resistance Temperature Detectors Pt25Q to Pt500Q 328 to 1562 F 200 to 850 C Pt500Q to Pt1000Q 328 to 662 F 200 to 350 C Cu25Q to Cu1000Q 58 to 482 F 50 to 250 C Thermocouples 932 to 3308 F 500 to 1820 C 90 F 32 to 4172 F 0 to 2300 C 180 F 418 to 1652 F 250 to 900 C 346 to 2192 F 210 to 1200 C 50 C F F 5 382 to 2498 F 230 to 1370 C F F F 5 100 C 50 C 328 to 1652 F 200 to 900 C 50 C 328 to 2372 F 200 to 1300 C 32 to 3182 F 0 to 1750 C 364 to 752 F 220 to 400 C
61. peratures Call Lesman Heat Trace RTDs with Replaceable Elements Features e Replaceable RTD element e Heat transfer pad conforms to pipe radius for fastest temperature response Rugged stainless steel sheath provides excellent mechanical protection 100Q RTDS with ranges from 0 to 1400 F depending on the construction Designed for NEMA 4 4X and Class Div 1 Model Selection Guide Catalog Description Number Heat Trace RTD with Replaceable Element NEMA 4 Cast Aluminum Head T1804 _ 115 00 Explosion Prf Cast Aluminum Head T1804X _ 160 00 o F UE s unique heat trace RTDs can save you time and money and increase overall system reliability and up time The unit features a terminal head and right angle shaped outer sheath with a curved weld pad at the end The replaceable RTD element assembly is contained in the outer tube and when installed presses against the pipe Heat transfer is excellent and heat conduction away from the element is minimal If the element ever needs to be replaced it s a five minute job to open the terminal head unwire the sensor slide it out and slide a new one in No downtime while you wait for insulation handlers welders and technicians to fit you into their schedules Recorders See page 85 Panel Meters See page 9 Controllers i See page 35 ee Sr E Temperature Transmitters See page 128 Illinois Indiana
62. ples don t last forever in most industrial applications they fail at a predictable interval one that s affected by temperature exposure to corrosive gases or liquids and environmental conditions Recommended Thermocouple Replacement Schedule Temperature Ranges T C Type 400 F and Below Type J or K Every 5 Years or More 900 to 1200 F Type K Every 1 or 2 Years 1200 to 1800 F Type K Every 6 to 12 Months 1800 to 2200 F Type K Every 3 Months 1800 F and Above Types R S or B Only as Needed Routine Thermocouple Replacement With today s focus on quality assurance calibration and ISO compli ance there s a high emphasis in making sure your process is running at the right temperature Talk to your Lesman sales consultant about implementing a replacement and calibration program to meet ISO compliance standards reduce downtime increase process quality and decrease the risk and frequency of accidents We can help inventory your thermocouple applications and make recommendations for creating a replacement program that fits If you need it your process can be contracted for scheduled replacement of thermocouples and parts protection tubes wiring connector blocks and head covers all when the system is cool and safe to work on Need service Your Lesman account manager can work with you to set up the program you need Custom Sensors Without Custom Pricing To help make your temperature assembly o
63. r DIN Rail Mount DC Power Supply MiniPower provides the total output capacity for more than 20 ms in the case of a power failure Mini Power has approvals such as UL 60 950 for IT equipment and UL 508 for industrial control equipment Status display LED green Ambient temperature 25 70 C gt 60 C derating Enclosure P20 Class 2 in an enclosed control cabinet Instal lation Horizontal DIN rail Approval UL EN60950 VDE 0805 SELV DINVDE0100 410 DIN VDE0106 1010 CEcompliance with EMC directive 89 336 EEC Emitted interference EN 50081 2 Immunity EN 61000 6 2 Model Selection Guide Catalog Description Number DIN Rail 24 VDC Power Supply 1A DIN Rail 24 VDC Power Supply 1 3A DIN Rail 24 VDC Power Supply 2A FA 2938840 108 17 FA 2866446 108 17 2938730 141 37 Switching DC Power ene e No jumpers or dip switches DIN rail or panel mount LED operation indicator e Universal AC input 85 264 VAC e DC compatible input 105 370 VDC b UL508 listing CE marking according to both LVD and EMC e Unique spring up finger safe terminals ideal for ring lug terminated wire e Auto resetting output over current protection 24 VDC Power Supply 15W 600mA Output 12 Length DIN Rail DIN Rail Clip Specifications Output Capacity 23 VDC at 300 mA Leakage Current 0 75mA max Input Voltage single phase 2 wire 100 240 VAC 85 264 VAC 50 60Hz 47 63Hz Overvoltage Protection Output
64. rder ing simple we ve listed the most popular models on these pages But if what you need isn t here you can still get it without paying a premium charge for special orders don t have to worry about any add on charges for modifications to the manufacturer s product If you can design describe or draw the tempera ture assembly you need we can supply it Call and ask for our Thermocouple Datasheet We ll fax it to you so that you can specify all the parts you need Then you can fax or mail it or call back We ll quote you a price and let you know when you can expect delivery It s that simple There s no need to worry about incompatibility or custom orders All Lesman thermocouples and RTD assemblies are made exactly to your specifications And since we start from scratch with your design you Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales lesman com Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 TEMPERATURE SENSORS V02 2011 Fax 262 923 1797 General Purpose Thermocouples Thermocouples with Quick Disconnect Plugs Features e Available in any length e Inconel or 316 stainless steel sheath 316 SS good to 1700 F Inconel good to 2100 F varies by sheath diameter e Plug and jack good to 350 F e Use with compression fittings Bend to any configuration Great
65. ruments and Systems SUOI EDIUNWIWO gt pue Bulsuas Ssajaul SIDUIWUPIBOJd s10 221pu JeWIHIG pue SJa JO1 U07D uoisinboy eeq pue s1 p102 4 4 dw fay o pe N 3 at D N SJOSU DINICJO SW JS S pue SjuaUUNI sSU Je217 jeuy TEMPERATURE SENSORS Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Lesman Instrument Company www lesman com sales lesman com IL us General Purpose Thermocouple Assemblies with Leads Features e Available in any length Model Selection Guide Type J Iron Constantan Thermocouple J18 012 00 15HT T1036 2 J28 012 00 15HT T1036 2 J38 012 00 15HT T1036 2 J48 012 00 15HT T1036 2 Type K Chromel Alumel Thermocouple K23 012 00 15HT T1036 2 e Inconel or 316 stainless steel sheath Price Adder per 6 Length 12 Sheath Length Grounded Un Catalog Number Exposed grounded Transition fitting with spring relief good to 1000 F e Use with compression fittings e Bend to any configuration you need 36 24 gauge Teflon leadwire standard Need a different sheath material or a dual element Call Lesman We can make almost anything you can describe Remember when wiring thermocouples red is always negative Inconel Inconel Inconel Temperature Range Selection Thermo
66. s All parameter settings are entry code protected Customer connections are also made as easy as possible using two part demountable terminal strips located on the rear panel The modular construction of System 4 ensures easy system expansion Mounting Options System 4 includes an extensive range of mountings and accessories that provide protection andaccuratealignmentforboth standard and fiberoptic thermometers All mountings permit quick tool free installation and removal of thermometers keeping downtime to a minimum See page 484 for emissivities of common materials Wireless Sensing and Communications Controllers and Programmers Digital Indicators Recorders and Data Acquisition 7a re O v 7a Sum c o GE we a a JS L oe oF Eo Analytical Instruments and Systems SUOI eDIUNWIWO gt pue Bulsuas ssejaul SIDUIWPIBOJd s10 221pu jebHIG pue SJa JO1 U0D uoisinboy eeq pue SJapsJODOY fey oO pe V 3 at D S5 7 SIOSUSS DINJeJoOdWwa SWa sKs pue SJUaWUNAYsU Je217 jeuy THERMAL IMAGING E 12s Fax 630 595 2386 Landscan LSP Infrared Linescanner Features e Compact size with a robust sapphire window e Wide scan 80 angle 100 1 field of view e Adjustable scan speed 10 to 100 Hz e Built in Class 2 laser to define scan plane and angle e Single cable connection between scanner and processor e Powerful software with single and mu
67. sion Catalog Number R11T185L483 04 CIP 1 5 63 R51T185L483 04 CIP 1 5 63 R11T185L483 04 CIP 2 5 63 R51T185L483 04 CIP 2 5 63 R11T185L483 05 CIP 1 5 63 R51T185L483 05 CIP 1 5 63 R11T185L483 05 CIP 2 5 63 R51T185L483 05 CIP 2 5 63 R11T185L483 05 CIP 3 5 63 R51T185L483 05 CIP 3 5 63 R11T185L483 06 CIP 1 5 63 R51T185L483 06 CIP 1 5 63 R11T185L483 06 CIP 2 5 63 R51T185L483 06 CIP 2 5 63 R11T185L483 06 CIP 3 5 63 R5T185L483 06 CIP 3 5 63 R11T185L483 06 CIP 4 5 63 R51T185L483 06 CIP 4 5 63 Catalog Number R11T185 156 83 02 CIP 075 5 63 R51T185 156 83 02 CIP 075 5 63 R11T185 156 83 02 CIP 075 5 63 R51T185 156 83 02 CIP 075 5 63 R11T185 156 83 04 CIP 075 5 63 R51T185 156 83 04 CIP 075 5 63 R11T185 156 83 04 CIP 075 5 63 R5T185 156 83 04 CIP 075 5 63 Number or 7 ransmitter by adding the following to your RTD assembly catalog number 1 450 U D S range C F Price Adder 105 00 ETAJ D 8 amp RTDs for the Food Industry 117 00 149 00 122 00 154 00 156 00 181 00 156 00 181 00 Price R5T185L68R383 04 HTST 1 5 63 HS 189 00 R5T185L68R383 04 HTST 2 5 63 HS 194 00 R5T185L68R383 05 HTST 1 5 63 HS 189 00 R5T185L68R383 05 HTST 2 5 63 HS 194 00 Controllers and Wireless Sensing and Programmers Communications Digital Indicators Recorders and Data Acquisition erature Sensors a VU 74 g0 Sa O 140 Temp Analytical Inst
68. staff will find the RTD that best meets your process measure ment needs Lesman Instrument Company www lesman com sales lesman com Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 V02 2011 Model Selection Guide Assemblies with Leads 0 01 0 01 0 01 0 01 Catalog Number for 12 Sheath Length R11T185L283 012 00 15 13036 2 R11T185L383 012 00 15 13036 2 R11T185L483 012 00 15 13036 2 R11T185L683 012 00 15 13036 2 R51T185L283 012 00 15 13036 2 R51T185L383 012 00 15 13036 2 R51T185L483 012 00 15 13036 2 R51T185L683 012 00 15 1T3036 2 TEMPERATURE SENSORS HWE S is Price Each Model Selection Guide Assemblies with Quick Disconnect Plugs Accuracy 0 01 0 01 0 01 0 01 Model Selection Guide Assemblies with Termination Heads Price Each 0 01 0 01 0 01 0 01 For All Assemblies To select a longer or shorter element length just insert in inches the length you wantin place of the 12 in digits 10 and 11 of the catalog number above R5T185L38123 Add 7 00 for each additional 6 length or part of 6 over 12 For Assemblies with Leads For a longer lead length just insert your desired length in inches in place of the 036 near the end of the catalog number Price of the additional lead length is 1 00 per foot Catalog Number for 12 Sheath Length R11T185L483 012 00 4MC R11T185L683 0
69. t Fair K20 1 304 0 92 0 97 als 0 76 0 81 Very Good K20 1 507 1 14 0 39 ServTex Braid Glass Braid Temp Plugs and Jacks edna Rating xaos Pe No Price aaa Ne Pie No Price Two Hollow Pins 7 16 Two Hollow Pins 7 16 Three Hollow Pins 7 16 Two Jab In Solid Pins 14Ga max 7 16 ve ae Two Jab In Solid Pins 8Ga max 7 16 ee Two Solid Pins 7 16 way B on Two Pins 5 16 SAal lad Three Pins 5 16 no Tt Two Pins 5 16 ee So Two Pins 5 16 Jab In z Bae oe o Insert calibration code in _ Use thermocouple type E J K N T R S or U for RTD Type N available Plug ee z in 61_ and 63_ only Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company Features e Laser targeting for accurate spot measurements pee narcn none 262 923 1707 SS ROTTS ee oO 2s SOLOnet Web Ready Infrared Thermometer 2 YN D gt AMETEK LAND ge a epi EES nn me Inlernationad Mlerenatt ern aos SV e Survives harsh environments and ambient temperatures up to 158 F with no added cooling requirement e Protection assemblies available for air and water cooling in ambient temperatures to 250 F or for extreme radiant heat e Field adjustable focal length four distances in one unit Pick one when you order and change in the field by swap ping focus rings to suit your changing needs e Sapphire protection window
70. that when wiring thermocouples red is always negative Model Selection Guide Process Length Catalog Brass Thread U Number 2 172 4 6 9 12 15 18 10 eD1p Uy jeWHIG 2 1 2 uoisinboy e1eq pue SJa9pPJODOY dw fay OL pe gt N at D N SJOSU DINJCJO For thermocouple extension wire see page 122 Need a compression fitting Call us SW S S pue SJUaWUNAYSU Je217 jeuy L 120 TEMPERATURE Illinois Indiana Missouri and lowa Lesman Instrument Company Wisconsin and Upper Peninsula Michigan Phone 800 953 7626 630 595 8400 J Phone 800 837 1700 262 923 1790 SENSORS eFax 630 595 2386 ick fanaa ce ay 262 923 1797 30 A zo Thermocouples with Matching Thermowells n N e Our most commonly requested thermocouples and match EN 9 9 ing thermowells aS a Most common materials listed Already have a thermowell but need a replacement thermocouple Just find the thermowell dimensions in the chart and select the ther mocouple It s that easy We use only spring loaded thermocouples with our thermowells Why Because spring loading ensures positive contact with the thermowell tip so the sensor responds faster to temperature changes Standard sheath material of the thermocouples is 316 stainless steel andthe 1 2 NPT connection that goes into the thermowellis carbon steel Other materials Inconel are avail
71. turns off at 105 typical Internal Fuse Rating 2A Overload Protection 120 typical Zener limiting Operating Conditions 14 to 140 F 10 to 60 C 20 to 90 rH Model Selection Guide Catalog Description Number 24 VDC Power Supply 7 5W 300mA Output PS5R A24 FA PS5R B24 BNDN 12 BNL5
72. uits electrically isolated Wireless Sensing and Communications Controllers and Programmers Digital Indicators Recorders and Data Acquisition 7a e o7 7a Sum c o GE we a a 3S L D E Ea Analytical Instruments and Systems SUOI EDIUNWIWO gt pue Bulsuas Ssajaul SIDUUWIPIBOJd s10 221pu JeIWIHIG pue SJa 01 U07D uoisinboy e1eq pue SJOPJODOY dw fey oO pe N 3 at D S5 7 SJOSU DINICJO SWa sKs pue SJUaWUNAYSU Je217 jeuy TEMPERATURE Phone 800 953 7626 630 595 8400 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Illinois Indiana Missouri and lowa Lesman Instrument Company TRANSMITTERS I PREY Fax 630 595 2386 SITRANS T Temperature Transmitters TF2 Field Mount Temperature Indicator with Integral RTD Features e IP65 rating e Integrated Pt100Q RTD input e High grade steel e 4 20 mA output e Local indicating display Three programming keys e 12 to 30 VDC power supply www lesman com sales lesman com Fax 262 923 1797 SIEMENS Please submit orders to Siemens Industry Inc c o Lesman Instrument Company Model Selection Guide Catalog Description Number Siemens SITRANSTF2 Field Temperature Indicator Transmitter with LCD display IP65 stainless steel housing sensor Pt100Q per DIN IEC 751 measuring range 50 to 200 C with local parameterization 4 20 mA
73. up of alarms emissivity and peak picker parameters Then all you do is connect the SOLOnet to its cable mount the unit and it s ready to go Specifications Model SN11 SN21 SN51 SNR1 Range F 1022 to 3182 482 to 2372 392 to2012 1292 to 3182 Wavelength Tum 1 6um 5um Tum ratio Field of View 100 1 100 1 50 1 100 1 Response 10ms 10ms 50ms 10ms Stability 0 2 0 2 0 2 K K 0 05K K Accuracy 0 3 K 2K 0 35 K 0 6 K Focus Fixed user configurable 9 87 19 77 39 47 and infinity Output 0 to 20 mA or 4 to 20 mA user selectable isolated 50V Ambient Limits 32 to 158 operating water cooled units can operate at temps to 250 F with insulated cables Non insulated cables good to 176 F Power Supply 18 to 30 VDC 24 VDC nominal Laser Sighting Laser defining optical axis Class 2 1mW 650 nm 120s ON duration automatic switch off Alarms High low internal temperature emissivity NG signal lost See page 484 for emissivities of common materials Wisconsin and Upper Peninsula Michigan INFRARED V02 2011 Sea a ee ee i Sore Paddar maipi Controllers and Programmers Digital Indicators Not sure what Ametek Land product is right for you Fill out the infrared thermometry datasheet at www Lesman com datasheets and fax it to Lesman for review Ordering Instructions Make one selection from each table section A finished catalog number looks like this SN11Y 250mm with 800858 A
74. y Polished gigs OD l Reduced Tip Hiir rohe 4 0375 OD Sheath p4 Cap Cap Size and Type 1 1 2 Triclover 16 AMP 2 Triclover 16 AMP 1 1 2 Triclover 16 AMP 2 Triclover 16 AMP Mini Temperature Transmitters for Small Spaces These miniature RTD transmitters are ideal for monitoring temperature in tanks and pipes The water tight construction meets the NEMA 6 IP68 protection ratings The unit includes an M12 process connection housing and a two wire transmitter with analog output Transmitters can be ranged from 60 to 320 F and accept Pt100Q inputs Transmitters on 3A Sanitary RTDs will have the 3A Sanitary approval and a 316 stainless steel Clean In Place connection To add a transmitter to your RTD assembly finish the assembly part number with the following T 450 f S range e where f the fault signal U for upscale D for downscale e engineering units C for Celsius F for Fahrenheit Example T 450 U S 0 200 F Add 105 00 to the assembly total price 55 Sanitary Accuracy 0 1 0 01 0 1 0 01 0 1 0 01 0 1 0 01 0 1 0 01 0 1 0 01 Accuracy 0 1 0 01 0 1 0 01 0 1 0 01 0 1 0 01 084 OD 30455 Conduit Opening HTST RTDs 3 8 O D Sheath Diameter Immersion Accuracy 0 01 0 01 0 01 0 01 Order this minit TEMPERATURE SENSORS V02 2011 Sanitary CIP RTDs 1 4 O D Sheath Diameter Immer