1. 4 6 3 ROI Polygon e Whenever you click the mouse left button new point is added Double click mouse left button to finish drawing You can modify the position of the object by clicking and dragging the object You can modify the shape of the object by clicking and dragging control point 4 6 4 ROI Free e Click mouse left button and drag You can modify the position of the object by clicking and dragging the object You can modify the shape of the object by clicking and dragging control point User Manual QuantorMed TM 702 EN S 4 6 5 ROI Property e If you click the right mouse button on the ROI a short cut menu Delete D will be displayed Property P e Delete deletes ROI e Property shows the property dialog box ROI Property Pacis 11117 ize Statistics Left 49 Height a Min Top 915 Width 2385 pixel Max Right 2434 Area 5017758 pixel 2671 787 Bottom 3017 Unit pixel ixi RI 663 630 Figure 4 5 ROI Property e Position Display rectangular coordinate of the ROI e Size Display height width and area of the ROI e Statistics Display minimum maximum mean and standard deviation values 4 6 6 Measure Distance e Click mouse left button and drag Distance is displayed at the end of the line You can modify the position of the object by clicking and d
2. In order to switch images click Switching Image button and select the image vou wish to switch User Manual QuantorMed TM 702 EN S 3 3 Image Stitching Option Stitching function supports 2 or 3 image stitching Stitch button is enabled when there are 2 more images in single study If there are stitched images in the study stitch button will be disabled You have to delete stitched image to make new stitch image ID000053 ANO00053 Emergency 2012 06 18 2012 06 18 LJ Fi Thorax PA Thorax PA Thorax PA 33333 ip Figure 3 9 Stitch Button User Manual QuantorMed TM 702 EN S 3 3 1 Screen Layout e Stitching window consists of image window and toolbar e Image window displays images from top to bottom by order of image number Image Window Toolbar Figure 3 10 Stitch Window User Manual QuantorMed TM 702 EN S 3 3 2 Buttons of Stitching Window Zoom In Out Zoom in out image Fit to Page Size Fit images to page size Pan Single Pan selected single image Pan All Pan all images Fit to Page Fit images to page width and align to next Wiath stitching region Show or hide clipping lines Clipping is used Clippi PRINS for removal of boundary area Guide Line Show or hide guide line 2 Point Auto Move images using 2 intersection points Detect and remove non exposure area Auto Remove automatically User Manual QuantorMed Mix Reset Rotate Left Rotate R
3. User Manual QuantorMed TM 702 EN S ID000052 M 0 ANO00052 Emergencv erer 18 2012 06 18 Procedure List CHEST_PA_L Thorax PA Thorax Lateral Figure 2 10 Predefined Study List User Manual QuantorMed TM 702 EN S 2 4 3 Edit Exam Select an exam in the Exam list Click Edit Mode button then Add Mode button will be released Body Part of selected Exam will be changed to newly selected Body Part Exam Position of selected Exam will be changed to newly selected Exam Position QEK ID000053 M 0 ANOUDDES Emergency 2012 06 18 2012 06 18 Thorax PA Thorax PA Thorax Lateral Thorax Decubitus Qd Site Ap Ribs Oblique Ribs PA Sternum Lateral Sternum Oblique Figure 2 11 Edit Exam User Manual QuantorMed TM 702 EN S 2 5 Image Acquisition 2 5 1 Acquisition Window Acquisition Window is composed of CR Control at the left half of the screen and Exam List at the right half of the screen Figure 2 12 Scan Buttons Scan Resolution ID000053 E M 0 ee Patient amp Study ESTO 2012 06 18 Information iet 79 AN200053 Selected Exam EI Thorax PA II CH Em yr Thorax PA Scan Progress E Ready for scan cun Figure 2 12 Acquisition Window e Select Exam e Change resolution if needed Press the Scan Button e image will come up after several seconds Figure 2 13 e Rectangular ROI Region of Interest box will be displayed automatically ROI box can be moved by drag
4. You can zoom in and out by clicking the left mouse button and moving it in any direction North and east directions zoom in the image South and west directions zoom out the image User Manual QuantorMed TM 702 EN S 4 5 3 Pan e Set mouse mode to pan You can move the image by mouse left button click and dragging 4 5 4 Magnify e Set mouse mode to magnify glass You can magnify small parts of the image by mouse left button click and moving Default zoom ratio is x2 Use with CTRL key to change zoom ratio Use with SHIFT key to change the size of the glass box 4 5 5 Rotate Right e Rotate selected images 90 right 4 5 6 Rotate Left e Rotate selected images 90 left 4 5 7 Flip Horizontally e Flip selected images horizontally 4 5 8 Flip Vertically e Flip selected images vertically 4 5 9 Inverse e Invert selected images 4 5 10 Display Original e Return selected images to original state User Manual QuantorMed TM 702 EN S 4 6 Annotation Menu 4 6 1 ROI Rectangle e Click mouse left button and drag You can modify the position of the object by clicking and dragging the object You can modify the shape of the object by clicking and dragging a control point 4 6 3 ROI Ellipse e Click mouse left button and drag You can modify the position of the object by clicking and dragging the object You can modify the shape of the object by clicking and dragging control point
5. 2012 06 18 y Information Thorax extremities Thorax ent L SES Thorax ty Thorax PA Thorax Lateral horax Decubitus Exam Ribs AP Ribs Oblique Sternum Lateral Sternum Oblique Exam List i Figure 2 7 Exam Window e Patient and Study Information will be always displayed at top of the window Figure 2 8 Select Edit button to edit information IDOOO0005 M 40 AN000005 Emergency 1970 01 01 2010 O7 02 Patient ID Patient Name Sex Age Study Date Accession No Birth Date Figure 2 8 Patient and Study Information User Manual QuantorMed TM 702 EN S 2 4 2 Add Exam a Select Body Part All related Exams will be displayed at Exam area b Select Exam c Selected Exam will be added to Exam List d If you select Exam with Add Study button selected predefined studies which have selected Exam will be displayed Figure 2 10 e Select Study f Selected Study will be added to Exam List 1D000053 F M 0 EEE AN000053 mergericy 2012 06 18 nds Thorax PA b Thorax PA Thorax Lateral Thorax Decubitus Ribs AP Ribs Oblique Ribs PA Sternum Lateral Sternum Oblique Figure 2 9 Add Exam e Exam List c displays all exams belonging to each study Acquired exam images are displayed as thumbnails and spots under the study bar show the status of image acquisition Dark spots represent exams which images were acquired exam and white spots represent exams which images were not acquired
6. If you select Input Window of Date selectable menu is displayed as shown blow Date User Manual QuantorMed TM 702 EN S Query Result e Study List query results up on each query condition are shown in Query Result e Each column of Study List can be sorted Click the title of each column to sort by the value of this column 2 6 2 Study Image Transfer e lia PACS is installed images are transferred to the DICOM Archive server after image acquisition and adjustment CAUTI ON QuantorMed provides image storage for temporary purpose So it is strongly recommended to transfer and store images in permanent storage after image acquisition for safety and security reasons e QuantorMed provides Study and image transfer auto transfer functions You can perform all other tasks in QuantorMed while Study and image are being transferred NOTE DICOM Archive server has to be configured appropriately in QuantorMed to transfer Study and images User Manual QuantorMed TM 702 EN S 2 6 3 CD DVD Write Option CD DVD Burning Device List Select Image Label 20120618_1700 Local Folder Log Message 39 0 0 0MB 0 00 Figure 2 16 CD DVD Write Choose Recorder Select recorder to burn media Volume Label Insert Volume Label Write Speed Select writing speed Burn Start burn to media Abort Abort burning Erase Erase rewritable media Close Close dialog box User Manual QuantorMed TM 7
7. ie Og 7 a o EE 53 S SE MET iU RER 53 AA c E F AX 54 e cM eei RT EE 54 4 5 5 Rotate Hot 54 A90 TOdo Eo tenement ien iba naked te ii audit 54 Ait Fip HOnNZOMally RE D oO TT 54 490 JUD vertically mankijiet S Drap Conf mox rei M ERR RN 54 439 AMON RR 54 49 10 REEL E 54 4 6 Annotation Menu 55 4 6 1 ROI RECIANGIS uie tins pao oca s dax te oua hte nett Sex Chee ink coeno teca 55 462 ROIL EIPSO are keasia Asiri E NEERA TOE EE EENE 55 AGS RO POYON EE 55 22 RO WE Onnin A TE 55 Z5 RAFO a i E A T E eee eer 56 4 6 6 Measure UDetance EE 56 4 6 7 Measure Angle EE 56 4 6 8 Measure 24010 T 57 L MEN RR 58 4 6 10 ATOW Lill nennen nennen nnne nnn nnn nsns r inna n inis earn nsns nnns earns n nnns 58 SACRE CRUS LTD 58 LO OMNE FIONA a a aa tfal tt transient 59 User Manual QuantorMed TM 702 EN S Chapter 1 Introduction QuantorMed is intuitive easy to use workstation software that provides facilities using 3D Imaging amp Simulations Corp CR readers with optimized image acquisition processing and management capabilities Its DICOM compliant interface allows for simple integration into a facility s HIS RIS and PACS providing the full range of capabilities needed for improved productivity and workflow in busy clinics and practices This user manual provides detailed information a
8. previous study to study list and open related images 4 2 7 Next Study e Add next study to study list and open related images User Manual QuantorMed TM 702 EN S 4 3 Edit Menu 4 3 1 Select Image e Select Image Select in the menu or press F1 key to select the image e Image is selected when the image is clicked by left mouse button Yellow box is displayed for the selected image e You can select multiple images by using the CTRL key and clicking each image using the left mouse button You can select a row of images by using the SHIFT key and clicking the first and the last image 4 3 2 Copy to Clipboard Copy active image to clipboard 4 3 3 Overlay Delete All e Delete all annotations from selected images 4 3 4 Select All e Select all images in current series 4 4 View Menu 4 4 1 Text Overlay e Show or hide text overlay 4 4 2 Annotation e Show or hide annotation User Manual QuantorMed TM 702 EN S 4 4 3 Ruler e Show or hide ruler 4 4 4 Toolbar Show or hide toolbar 4 4 5 Caption e Show or hide caption 4 4 6 Study List e Show or hide study list 4 4 7 ull Screen e Hide caption toolbar study list and maximize the image window 4 4 8 Reset View e Show toolbar caption and study list 4 5 Image Menu 4 5 1 Select e Set mouse mode to select At select mode you can select image and annotation 4 5 2 Zoom e Set mouse mode to zoom
9. sex Male is the default setting Input study accession number in Acc No field Accession number is not a required field Input study referring physician in Ref Phy field Referring physician is not a required Input study description in Study Desc field User Manual QuantorMed TM 702 EN S 2 2 2 Buttons of the New Study Window Description Previous Window Go back to the previous window Start Study Add new study and start study Emergency Fill patient and study information automatically 2 2 3 Patient and Study Information EE m nmm User Manual QuantorMed TM 702 EN S 2 3 Edit Column 2 3 1 Edit Column Window You can add or remove columns in Edit Column Window Edit Column Sch Date Selected Columns Hidden Columns Figure 2 6 Edit Column Window e Left Column List that is displayed in column header in Work List and Study List Right Column List that is not displayed in column head in Work List and Study List e Order of Edit Column list is identical to the order of column header in Work List and Study List User Manual QuantorMed TM 702 EN S 2 4 Add Exam 2 4 1 Exam Window If you select Start Study button in Work List Window or in Add Study Window Exam Window Figure 2 7 will come up If the Scheduled Procedure Description or ID of the study matches with database exam will be added automatically Patient and 10000052 M A 06 Stud ANOOOOS Emergency 2012 06 18
10. studies at Image window E Bg z BE Use study layout toolbar to change study layout otudy Layout 1x1 Study ayout gt Study Layout 1x2 gt Study Layout 2x1 gt Study Layout 2x2 First Study Second Study fr 3 ID EH 3 ID000003 Emergency M 41 CHEST 2011 0 DE F IDOOOOQ3 1970 01 01 0 k emergency 160mm Figure 4 2 Change Layout User Manual QuantorMed TM 702 EN S 4 1 3 Study List Patient Study List e Study List Window displays all open studies e If you select study at study list Patient Study List Window will display all studies of the same patient You can open study by select and dragging study on the Study List Window or Patient Study List Window 4 1 4 Set Image Manipulation Apply Range There are 4 application ranges Active Select Study All Active Current Image Select All selected Images Study All images of current study Apply All All opened images V NW NW ON e Following image manipulations works for apply range Export gt Zoom Pan gt Rotate Flip Invert gt Window Level Y 4 1 5 Short Cut Key There are 5 short cut keys F1 Select Fi oom F3 Pan F Magnify F5 Full Screen F1 Select F2 Zoom F3 Pan F4 Magnify F5 Full Screen VV VV WV User Manual QuantorMed TM 702 EN S 4 2 File Menu 4 2 1 Open DICOM Files e Open DICOM files and display image e You can select multiple images at Open File Dialog Box 4 2 2 Ope
11. 02 EN S 2 Transport Status 2 7 1 Transport Status Window You can check send and print information on Transport Status Window Figure 2 17 Transport Status 2009 04 1 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 18 46 59 18 46 01 18 44 10 18 42 53 18 41 55 18 41 75 18 40 57 18 40 47 18 40 08 18 20 23 18 20 21 18 19 51 18 19 50 VIEWER VIEWER VIEWER VIEWER VIEWER VIEWER VIEWER VIEWER VIEWER BUNNY VIEWER BUNNY VIEWER Figure 2 17 Transport Status Window 192 168 1 101 192 168 1 101 192 168 1 101 192 168 1 101 192 168 1 101 192 168 1 101 192 168 1 101 192 168 1 101 192 168 1 101 192 168 1 111 192 168 1 111 192 168 1 111 192 168 1 111 Port PatName 4000 4000 4000 4000 4000 4000 4000 4000 4000 3000 3000 3000 3000 6 6 6 6 6 6 6 6 6 3 3 i User Manual QuantorMed 2 2 Start Date Start Time Lap Time AE Title Host Port PatName Hall Status TM 702 EN S Columns of Transport List Start Date of Transport Query format is one of following YYYY MM DD YYYY MM DD YYYY MM DD YYYYMMDD MM DD MM DD DD Blank will be changed to today automatically Start time of transport Query format is one of the following HH MM HHMM Blank will be changed to 00 00 automatically Transport Status User Manual
12. 4102406 04102407 04102408 04102409 04102410 04102501 04102502 04102503 04102504 04102505 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 HAND AP BOTH HAND AP BOTH HAND AP BOTH HAND AP BOTH HAND AP BOS HAND AP BOTH HAND AP BOTH HAND AP BOTH HAND AP BOTH HAND AP BOTH HAND AP BOTH HAND AP BOTH HAND AP BOTH HAND AP BOTH HAND AP BOTH Page Input Window Query Result Page Up Page Down Figure 2 4 Work List Window You can input query conditions for all columns You can scroll through pages using the page up down buttons or mouse wheel button Page information is Current Page Total Page format Input Window Query Condition This is input field for query condition Type query condition in each column of Input Window and click Search button In order to use Auto Query function Auto Query interval has to be set in QuantorMedSetting and its unit is minute Query Result Worklist query results up on each query condition are shown in Query Result Each column of the Worklist can be sorted Click the title of each column to sort by the value of this column User Manual QuantorMed TM 702 EN S 2 1 3 Columns of Work List Description Sch Date Scheduled Study Date Query format is one of following YYYY MM DD VV MM DD YYY
13. 560 Glenn Dr Suite 116 Sterling VA 20164 USA Tel 1 703 430 6080 E mail sas 3DISCimaging com EC REP 3DISC Europe Gydevang 39 41 3450 Alleroed Denmark Tel 45 88 276 650 E mail twe 3DISCimaging com User Manual QuantorMed TM 702 EN S Warnings and used symbols To ensure the safety of patients staff and other persons any changes to software and hardware delivered by 3D Imaging amp Simulations Corp may only be made with prior written permission from 3D Imaging amp Simulations Corp Please read the respective manuals of the connected devices such as of the X ray generator sensor or reader before starting to use the QuantorMed software The following symbols will be used throughout this manual DANGER The functionality of the software can be destroyed in the case of incorrect use If unauthorized changes have been made to delivered software and hardware components the warranty by 3D Imaging amp Simulations Corp becomes void 3D Imaging amp Simulations Corp will not accept any responsibility or liability for the proper functioning oh the product in such a case CAUTION The functionality of the software can be limited in the case of incorrect use Hints that require special attention NOTE Notes represent information that is important to Know but which do not affect the functionality of the software User Manual QuantorMed TM 702 EN S Medical Device Security v User Authenticati
14. Quantor User Manual Human Acquisition and diagnostic software Doc No TM 702 EN S Rev 0 1 4 Jan 2012 Part No CR FPM 04 001 EN S 3DISC FireCR Quantor and the 3D Cube are trademarks of 3D Imaging amp Simulation s Corp South Korea and its affiliates All other trademarks are held by their respective owners and are used in an editorial fashion with no intention of infringement The data in this publication are for illustration purposes only and do not necessarily represent standa rds or specifications which must be met by 3D Imaging amp Simulations Corp All inform ation contained herein is intended for guidance purposes only and characteristics of the products and services described in this publication can be changed at any time without n otice Products and services may not be available in your local area Please contact your local sales representative for availability information 3D Imaging amp Simulations Corp s trives to provide as accurate information as possible but shall not be responsible for any typographical error Copyright 2010 3D Imaging amp Simulations Corp all rights reserved printed and published in South Korea by 3D Imaging amp Simulations Corp IMAGING User Manual QuantorMed TM 702 EN S Contact SDISC MAGING 815 Tamnip Dong Yuseong Gu Daejeon Korea Tel 82 42 931 2100 Fax 82 42 931 2299 Website www 3DlSCimaging com E mail info 3DISCimaging com 3DISC Americas 22
15. QuantorMed TM 702 EN S 2 8 Print Option 2 8 1 Print Window You can print multiple 1 4 images on a single film using Print Window Print Preview is displayed on the left side of the window You can add images to Print preview by selecting an exam and clicking on the Print Preview 1D000053 M AN000053 0 Emergency TTIE 2012 06 18 Ji Thorax PA d Thorax PA Thorax PA Print Preview Figure 2 18 Print Window e QuantorMed provides DICOM print function and image layout can be configured in preview window NOTE DICOM Printer has to be configured appropriately in QuantorMed to transfer Study and images to DICOM Printer User Manual QuantorMed TM 702 EN S 2 8 2 Buttons of the Print Window 1 row 1 column mode 2 row 1 column mode 1 row 2 column mode 2 row 2 column mode Start Print Start Print Send to Print Server Move to Main Window User Manual QuantorMed TM 702 EN S Chapter 3 Image Manipulation 3 1 Image Manipulation 3 1 1 Image Manipulation Window You can adjust image processing by pressing the QA button Figure 3 1 is a QA Quality Assurance window Image is displayed at left half and various controls are displayed at right half 700525 2010 06 21 PE a e 1235 I Predefined Figure 3 1 QA Window User Manual QuantorMed TM 702 EN S 3 1 2 Marking e Write text to insert in the image Enter string to input box and press button and click at
16. S Calibration Geometry X Ray Tube SID 100cm Cassette Figure 1 14 Calibration Geometry CAUTION X ray radiation field must cover the whole area of the cassette User Manual QuantorMed TM 702 EN S Chapter 2 Acquisition 2 1 Add Study There are two methods for creating a study One is to retrieve study information from a Work List server and the other is to input study information manually NOTE DICOM Worklist server has to be configured appropriately in QuantorMed to add studies from Worklist server 2 1 1 Create Study Using Work List e Select Work List button at Start Window Figure 2 1 Work List Button e Select Query Server button at Work List Window Figure 2 2 Query Server Button e Select desired study in the Work List Window e Select Start Study button in the Work List Window Figure 2 3 Start Study Button User Manual QuantorMed 2 1 2 Work List Window TM 702 EN S You can query Work List using various options in the Work List Window as shown in Figure 2 4 The Work List Window consists of function buttons and a list which displays query results Work List 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 2009 04 10 18 09 25 18 09 25 18 09 25 18 09 25 04102401 04102402 04102403 04102404 04102405 0
17. Y MM DD YYYYMMDD MM DD MM DD DD Blank will be changed to today automatically Sch Time Scheduled Study Time Query format is one of following HH MM HHMM Blank will be changed to 00 00 automatically Mod Modality StationAE Station Application Entity Title Name Patient Name Patient ID Patient Sex Only M F O are used for query D X lt Birth Patient Birth Date Age Patient Age Procedure Scheduled Description Station Name Procedure Scheduled ID Accession Number Referring Physician User Manual QuantorMed TM 702 EN S 2 2 Add Study Manual 2 2 1 New Study Window You can add new study at the New Study Window If you use touch screen monitor select input window and use Keyboard Panel a CK XxX fare Esc J xi r 8kSp Home PgUp Keyboard Panel Function Buttons Figure 2 5 New Study Window Input patient ID in ID field ID is a required field Input patient name in Name field Name is a required field Input patient date of birth in Birth Date field This is not a required field but either Birth Date or Age has to be input In case that only Age field is input year of Birth Date is calculated automatically and displayed in the Birth Date field with the month and date of January 1 Input patient age in Age field In case that both Birth Date and Age are input Age is recalculated based on Birth Date Select patient
18. antorView Express 47 Bits DOV CWT AV OU Tt 47 4 1 1 Screen Layout and Name of Parts ses snennnnnnznnnnanznnnnnnzzznnanrnnannnnzznnnnn 47 4 1 2 Change Study Layout at Image Window ss eennnnzznnnnnnzznnnnzzzannnnnznzzntzzza 48 4 1 3 Study List Patient Study Uert 49 4 1 4 Set Image Manipulation Apply Range neenennznnnnnnnenznnnnnnnnnanznzznnnn nn 49 4 1 5 Short Cut Key cc eccceecccceceseeeeseeeeeseeeeeeeeeeeeeeeseeeeseeeeeeeeseeaeeeeeeeessssaggeses 49 4 2 File Men 50 4 2 1 Open DICOM Files sasinan aaa ode iaaii 50 4 2 2 Open Non DICOM Files 0 00 0 ec ccccccceccceseeseeeeeeeeeseeeeseeeeeeeessaeaeeeeeeesssaaaaeess 50 deo EDO GE 50 23 05 4000 eaa E E E E E eee eee eee 51 dZ e E TE 51 4 2 6 PYEVIOUS SUUGY E 51 4 2 7 Next Study 0 ccccccceccssceeeeecesccccosseeeeeeeecccceeseeeceeessnccesseceessecceesenseeeessssacesses 51 LA E LU 52 E Ee NIAC sia a AS a m o mE EE 52 4 3 2 Gopvlo 8 0 0161 1 6 NE TE TT 52 User Manual QuantorMed ai TM 702 EN S 4 3 3 Overlay Delete All nn nanna nennen nnn 52 2300 EE 0 12 2 E 52 4 4 View Menu 52 dA Ee EK 52 4 4 2 Annotation ce 52 SN e 53 Ad 618 E 53 Be MEME Eee NAM 53 4 4 6 Study Uert ENNEN 53 e er UM SONS CM RR 53 4 4 8 Reset VIEW sibi nie tipa ika ibza fa a a io ika ke 53 Los WAC CIVIC
19. bout the operation of QuantorMed and the use of the range of facilities included in the software to make the processing and administration of your medical X ray images as efficient as possible Safety Instruction To ensure the safety of patients staff and other persons any changes to software and hardware delivered by 3D Imaging amp Simulations Corp may only be made with prior written permission from 3D Imaging amp Simulations Corp Liability If unauthorized changes have been made to delivered software and hardware components the warranty by 3D Imaging amp Simulations Corp becomes void 3D Imaging amp Simulations Corp will not accept any responsibility or liability for the improper functioning of the product in such a case QuantorMed is not approved for the acquisition of mammographic image data User Manual QuantorMed TM 702 EN S 1 1 Main Features Image Acquisition amp Study Management QuantorMed Software allows facilities to quickly input patient data or access it directly from their HIS RIS or PACS for improved productivity and accuracy Image acquisition is supported by a fully developed list of exams and anatomies and a viewer displays images on a monitor to facilitate quality control and image management Once completed the study can be sent to the PACS printed on a dry film printer or burned onto a CD or DVD Image Manipulation Multi Viewing amp Stitching To optimize images technicians can cr
20. clicked ROI box appears for adjustment when the image is double clicked Stitching button is enabled when there are more than 2 exam images NOTE Refer to Chapter 4 3 Image Stitching e Close the study by clicking End Study button when all image acquisitions are finished e lf Auto Send button is enabled non transferred images in study are transferred to the archive server automatically when study ends User Manual QuantorMed TM 702 EN S 2 6 Study Management 2 6 1 Study List Window Studies can be managed at the Study List Figure 2 15 You can search delete edit and send studies at the Study List Study List Page Input Window Emergency IDDA Emergency IDODDCLAB Emergency IDODO0 27 Emergency TEOHOQO 26 N d Emergency 10000025 Sacrum 2 Que ry Result Emergency TO 24 y Wazal 1 Emergency IL ODDO 3S I Mandible Fending Emergency ILHOLHLIL Z2 I KUB Serie Emergency ILM 1 I Hip 16 56 58 Emergency IDOO0020 hy Hand 16 46 17 Emergency IDO000189 h Coccyx Pag e U p 16 37 06 Emergency IDOOQO 18 Caleaneus 5 flee Emergency IDOODU 3 I Patella Emergency ILA I Pelis l sert Page Down Emergency ILA I Figure 2 15 Study List Window You can page up down using buttons and mouse wheel button e Page information is Current Page Total Page format Input Window Query Condition e This is the input field for query condition Type query in each column of Input Window and click Search button e
21. djust window center using slide control Window Width You can adjust Window width using slide control Set Load Curve e y E Reset Histogram Center ant Window Center os Width Window Width t Figure 3 6 LUT User Manual QuantorMed TM 702 EN S 3 1 5 Processing Contrast Control the level of contrast enhancement Detail Contrast Control the level of detail contrast enhancement Edge Enhancement Control the level of edge enhancement Edge Frequency Control the frequency of edge Dynamic Range Comp Control the level dynamic range compress ratio Noise Reduction Level Control the level of noise reduction Set Save current curve as default value of current exam Load Load default curve of the exam Reset Remove all control points BEI Contrast 3 a usd Detail Contrast 6 E3 l Edge Enhancement ui 2 H Edge Frequency a 2 HEN Diani Range Comp CN 6 Noise Reduction Level 10 d IK Reset Figure 3 7 Processing User Manual QuantorMed TM 702 EN S 3 2 Multi View 3 2 1 Multi View Window You can change the order of images or delete images easily in the multi view window 1D000023 M 41 cue ANDODO23 E m ergency 1970 01 01 2011 02 1 UR el i Page Switching Image Page Up Page Down Figure 3 8 Multi View Window e Switching Image button is a toggle button on off
22. ging Size of ROI can be modified by dragging the small control boxes e ROl is applied by double clicking the ROI box Figure 2 14 is the ROI applied image e Select next Exam and repeat above process User Manual QuantorMed TM 702 EN S 2 5 2 Exam Review Window ANOODD35 2012 06 01 IDOOQO035 a M A ry Nadssituation 2012 06 01 D P Figure 2 13 Acquired Image e Scanned images are displayed as shown in Figure 2 13 and ROI box and marks are displayed on the image NOTE ROI size Mark and Mark position can be created and edited in QuantorMed Organizer e Size and position of ROI and Mark can be adjusted and moved by dragging of the mouse with the left mouse button click e Window settings can be adjusted by dragging the mouse with the right mouse button clicked e After ROI adjustment ROI is applied to the image by double clicking of the left mouse button This adjustment is applied to Thumbnail image in the Exam list User Manual QuantorMed TM 702 EN S IDO000035 M 0 sro Nodssituation en 2012 06 01 horax PA Thorax PA Thorax PA l i EL Addc Ko D A dy Figure 2 14 ROI Applied Image ROI applied image is displayed as shown in Figure 2 14 Selected Exam can be retaken by using Retake button Auto Window button finds optimized window settings for the ROI applied image Window settings of the image can be adjusted by dragging the mouse with the right mouse button
23. icious user could exploit locally Some examples are e Theft of equipment e Local password cracking e Installation of hardware keyloggers User Manual QuantorMed TM 702 EN S Index of contents Chapter 1 Introduction ss sess nennnnnnnnnnnananznznnnnznnenznnenznnenznnnnz nn 8 1 1 Main PC QUIS 9 ta laa TOMA ON ccm 10 tat System EE GE 10 EE EE cci die cR E oT 10 29 TOMNA FOCI a TU UTIMS 11 Lo 2 6 860 20 Em 12 1 3 1 Calibration Geometry sseeseesssssssesseennn nennen nennen nnne nnns 13 Chapter 2 Acoutsifton sess ennnnnnnnnnnznnnznnnenznnenznznnnnnenanznznnnnzza 14 201 ROO DUG i a 14 2 1 1 Create Study Using Work et 14 2 1 2 Work List Window lee nennen n nnne nnn nnns 15 2 1 9 Columns of Work EE 16 2 2 Add Study Manual nnennnnnnnnnnnnnnznnnnnnnnnnnnnnnananananana za nnnna 17 2 2 1 New Study WINKOW EEN 17 2 2 2 Buttons of the New Study Window e nennnzennnnnznninzzznnnenenznznnzznnnnnnznzznnna 18 2 2 8 Patient and Study Information sess 18 2 0 BOL COol t m ei i E E 19 2 0 1 Edit Column WIndOW EE 19 2 4 ACG EX A i RC ROC d teas Perte dtu See ROR RT b deve ARE nS ROTA ID 20 Lr EE Riso ata ae a si a i REER 20 Edo Mad EA e ee ee ee ee eee ee een DIE DUE 21 ZR EC EE e CMT TUE 23 ro MAEA O MN ie E E 24 2 5 1 Acquisition VWmdow 24 202 Exam R VIOW VVIRQO WA iku rna ka ii e Fal M RU C GRE 25 2 60 Sidy Mangement uentum Uc pues e
24. ight Angle Cancel Stitch TM 702 EN S On Off mix intersection function Mix function makes overlapping area look natural and smooth by fade in out effects Reset all images to initial state Rotate selected image to left side Rotate selected image to right side Change the rotating angle Click this button will show combo box of 5 angles 0 01 0 05 0 1 0 5 1 Select new angle Cancel stitching and return to previous screen Stitch images and return to previous screen User Manual QuantorMed TM 702 EN S 3 3 3 Clip Images Turn on Clipping button Dotted line will be displayed around the images Selected image has green line and the others have yellow line Moving mouse on to the line will change the cursor style to arrow Click mouse left button and move the line to requested position Turn off clipping button will make clipping line invisible Figure 3 11 Clipping Lines User Manual QuantorMed TM 702 EN S 3 3 4 Removal of Non Exposure Area Automatically Non exposure area is where X ray is not exposed e Selection of Auto Remove button will detect and remove non exposure area Non Exposure Area Figure 3 12 Removing Non Exposure Area User Manual QuantorMed TM 702 EN S 3 3 5 2 Point Automatic Function e 2 Point Auto function uses 2 images Upper image is the first image and lower image is the second image Select 2 Point Auto button Click inte
25. n Non DICOM Files Open non DICOM files JPEG Bitmap Tiff e You can select multiple images at Open File Dialog Box 4 2 3 Export Save As e ek E fi Libraries i EIOHLEI zu System Folder System Folder B com puter Network System Folder A System Folder chest dcm DCM File 28 5 MB Save as type DICOM File dcm Transfer Syntanx Figure 4 3 Export e Export selected DICOM image as different image file format e File Name Insert new file name e File Type Select one of following formats gt DICOM Files DICOM type gt JPEG Files JPEG type gt Bitmap Files Windows bitmap type User Manual QuantorMed TM 702 EN S gt TIFF Files TIFF type gt AVI File Windows AVI type You have to select more than 2 images with same series e Transfer Syntax Enabled when you select DICOM type gt Keep Original Keep the original Transfer Syntax Uncompressed Do not use compressing If selected image is compressed it will be saved as uncompressed gt JPEG Baseline JPEG 8bit gt JPEG 12bit Lossy JPEG 12bit gt JPEG 16bit Lossless JPEG 16bit lossless e Quality Enabled when you use lossy JPEG codec gt Low JPEG Q Value 10 Low Mid JPEG Q Value 25 Mid JPEG Q Value 50 Mid High JPEG Q Value 75 High JPEG Q Value 90 VV ON WV 4 2 4 Close e Close selected study and related images 4 2 5 Close All e Close all studies and related images 4 2 6 Previous Study e Add
26. ndow Quantorded Figure 1 10 Short Cut Icon User Manual QuantorMed TM 702 EN S 1 2 3 Terminate Program Select System button as shown in Figure 1 11 on main Window Figure 1 11 System Button Now you can Exit Application or Shut Down System by selecting buttons in the System Menu Shut Down System will turn off your workstation QuantorMedDhmaorn Ver 1 0 128 1 1 1 Update Shut Down System Exit Application Figure 1 12 System Menu User Manual QuantorMed TM 702 EN S 1 3 FireCR Calibration Select IP Calibration in System Menu then following window will pop up Follow the steps of the menu or click Help for more information CAUTION Calibrate the scanner before use Please calibrate system message pops up if the scanner is not calibrated or calibration data does not exist It is recommended to calibrate the reader after moving it and as a part of regular maintenance The X ray beam should cover the entire cassette area f ii Auto alignment Calibration CC DL U 11D OL Il LL 80 300 2000 4000 9000 14000 31000 36000 u H 0 0kVp 50 0kVp 50 0kVp 50 0kVp 0 0mAs 0 4mAs 1 8mAs 5 4mAs SID1 0m SID1 0m SID1 0m SID1 0m Figure 1 13 IP Calibration CAUTION Calibration should be done for both Universal Cassette containing IP 14 x 17 and Universal Cassette containing IP 10 x 12 User Manual QuantorMed 1 3 1 TM 702 EN
27. on Only authorized users should logon to computers on which medical information systems are installed Password Security In today s world passwords can be compromised in literally seconds by using a wide variety of tools and techniques To lower the possibility of a compromised password it is vital to adhere to a set of protocols Choose a password between 7 10 characters using both alpha and numeric characters Do not share the password Do not base the password on a pet relative or dictionary name Do not write down the password Do not leave the account logged on User Access Control Configure the workstation to prompt for logon after coming out of stand by mode Internet Usage Accessing to the Internet exposes the computer to a plethora of vulnerabilities such as e Virus e Spyware e Trojans e Hostile Code It is not recommended to install any unauthorized software on the computer Peer to peer software can expose your entire hard drive to any individual running the same type of software Antivirus Products Use of antivirus software can increase CPU and memory usage which can cause a slight degradation in the performance of the system However functionality should not be affected Physical Security It is recommended that the user employs some method of physical security when dealing with the system to ensure that only authorized personnel have access to the product There are several vulnerabilities a mal
28. op etch enhance increase brightness and contrast and perform other adjustments Regions of interest can be highlighted and users can easily change the order of images or delete images at the multi view window Stitching capabilities for images of legs spines and other anatomical areas are particularly useful for orthopedic and chiropractic facilities QuantorView Express For smaller facilities without a HIS RIS or PACS QuantorMeds local database enables direct management of patients and studies utilizing a unique viewer function Technicians and radiologists can review DICOM and non DICOM images on the same station they acquired it on Full Range of Output Options QuantorMed features a full range of output options including DICOM CD burn embedded view DICOM send SCU and DICOM print for dry film printers The combined DICOM Patient CD and dry film print option creates patient CD DVDs that include DICOM DIR structure and a built in viewer User Manual QuantorMed TM 702 EN S 1 2 Start and Termination 1 2 4 System Start 1 Turn on FireCR CR Reader 2 Turn on monitor and PC CAUTI ON Do not execute other application software than QuantorMed during operation of the scanner This may slow the scanner response 1 2 2 Start Program After Windows is successfully booted you can launch the QuantorMed program by double clicking the QuantorMed icon on your desktop as shown in figure 1 10 Figure 1 9 Start Wi
29. pu tesa been Ue pu uua pau eu bua A see 27 2 6 1 Study List Window seeeeeesssssseesseeeeneeenenn nennen nnne nnne nnne nnns 27 2 6 2 Study Image Transfer ss nnnennnnnnnnnnn nanna rna nn nanna mnn nn nn nnnn nn nnnnna 28 2 55 GDP DVD Write OPON eegene 29 Se RPO QS o a aE a A A E AAE AEA AA 30 2 7 1 Transport Status Window sseesssssssssseeeeeee nnne nnne nnns 30 2 7 2 Columns of Transport List zz nn 31 User Manual QuantorMed TM 702 EN S 2 FOOD e sin EE neers eerie eres 32 291s iiM inet MR T 32 2 8 2 Buttons of the Print Window eeeesseeesssseeseseeeenenn nennen 33 Chapter 3 Image Manipulation 2 sss ses snnnnnnnannenazenznnnnnzzznzzs 34 3 imiiagedanipulatlon iwessa ina tas ui e ada ada d 34 3 1 1 Image Manipulation Window e ss ennnnnnnnn mnn nanna nanna nn tn nanna nn 34 aTe ci de Im mm 35 3 1 3 ROI Region of Interest nanna nn nanna nnne 36 341 4 EE LOOK Up Table onini rone deeg egen 37 Sur EE uso e E 38 3 2 Multi Mie 39 3 2 1 Multi View WINDOW sies rezi nieda ita A aa 39 J 9 dMage Stitching ODIIOn isi rrr riri nhe Ze 40 aab STen 0 0 eege 41 3 3 2 Buttons of Stitching Wmdow 42 Duos e Mun Sa B 44 3 3 4 Removal of Non Exposure Area Automatically ccccccsccecsseeeeeeeeeeeeenaeees 45 3 3 5 2 Point Automatic Function sen nnnnna mnn nanna nanna nn nn E 46 Chapter 4 Qu
30. ragging the object You can modify the shape of the object by clicking and dragging a control point 4 6 7 Measure Angle e Click mouse left button three times at center left right of the angle e Inner angle and outer angle are displayed You can modify the position of the object by clicking and dragging the object You can modify the shape of the object by clicking and dragging a control point User Manual QuantorMed TM 702 EN S 4 6 8 Measure CTR Click the left mouse button at the left end of the chest a Drag mouse to the right end of the chest b Release mouse button Click control point c and move to the left end of the heart Click control point d and move to the right end of the heart Width of the heart will be displayed at d Width of the chest will be displayed at b CTR will be displayed as You can modify the position of each line by clicking and dragging the line You can modify the shape of the object by clicking and dragging control point Figure 4 6 CTR User Manual QuantorMed TM 702 EN S 46 9 Text Click the left mouse button or draw a rectangle by clicking and dragging Edit box will come up Add your text Click the left mouse button on the outside of the edit box You can modify the position of the object by clicking and dragging the object You can modify the shape of the object by clicking and dragging a control point 4 6 10 Arrow e Click mo
31. rsection point on the first image Red cross mark will be displayed Click intersection point on the second image Second image will move to the first image so that the intersection point of the second image matches the intersection point of the first image Figure 3 13 2 Point Auto User Manual QuantorMed TM 702 EN S Chapter 4 QuantorView Express Screen Layout 4 1 1 Screen Layout and Name of Parts Juantorviewertxpress File F Edit E View V Image l Annotation A About B mi ms E ME ES SE Rectangle Ellipse Polygon Free Distance Angle jSelec Elipse Polygon Free Distance Angle Select Zoom Pan Magnify Rotate Right Rotate Left FlipH Flipv Inverse Reset t Zoom Pan Magnify Rotate Right Rotate Left FipH ripV Inverse Reset l 1 ee t E 3 ID000003 Emergency M 41 CHEST 2011 02 11 09 47 12 ID000003 1970 01 01 M 41Y 1 D000003 1970 01 01 M 41Y 2 Emergency 2011 02 11 Emergency 2011 02 11 l 09 47 12 09 47 12 SEHTIL E SE 1 IM 1 E IM 2 100mm B a 100mm 4260 x 3484 l Den x 3500 C 1036 W 4707 C 2096 W 414 F AAOL 77 A AOL e U E fat e Fi Select F2 Zoom F3 Pan F4 Magnify F5 Full Screen Active Select Study All Figure 4 1 Screen Layout e Viewer screen is composed of following parts a Upper Toolbar Study List c Patient Study List d Image Window e Lower Toolbar User Manual QuantorMed TM 702 EN S 4 1 2 Change Study Layout at Image Window You can see multiple
32. the position you want to insert on the image Predefined You can insert predefined Markings on the image Select predefined marking and select button and click at the position you want to insert on the image Vertical Flip Flip image vertically Horizontal Flip Flip image horizontally Rotate Right Rotate image to right Rotate Left Rotate image to left Vertical Flip Rotate Right Figure 3 3 Predefined Marking Horizontal Flip Rotate Left Figure 3 2 Marking User Manual QuantorMed TM 702 EN S 3 1 3 ROI Region of Interest e ROI Show Hide Show or hide ROI rectangular box ROI Size Setting Set ROI Size If you press this all ROI sizes will be displayed e ROI Move Buttons You can move the ROI by pressing Left Top Right and Bottom buttons ROI ROI Show Hide ROI Size Setting A ROI lt b Move Button v Figure 3 4 ROI Control Buttons Figure 3 5 ROI Size Setting User Manual QuantorMed TM 702 EN S 3 1 4 LUT Look Up Table Curve You can define the curve by click and drag the control point You can add control point by click on the line You can remove a control point by clicking and dragging it to the outside of the curve box Set Save current curve as default value of current exam Load Load default curve of the exam Reset Remove all control points Histogram Shows histogram of the image Window Center You can a
33. use left button and drag You can modify the position of the object by clicking and dragging the object You can modify the shape of the object by clicking and dragging a control point 4 6 11 Pixel View e Click mouse left button and drag e Asmall white box will show pixel coordinate and value X 8 9 y 909 p 1642 User Manual QuantorMed TM 702 EN S 4 6 12 Profile e Click mouse left button and drag e Releasing the left mouse button will show profile dialog box e f you click and drag left mouse button on the profile graph red point will be displayed on the image which indicates current position on the graph You can modify the position of the object by clicking and dragging the object You can modify the shape of the object by clicking and dragging a control point e Right clicking the line will show a short cut menu which enables you to show the profile dialog box Distance 200 2 7mm Start Point X 601 Y 1952 End Point X 2600 Y 2074 Min 1326 Max 3852 Mean 2838 428 Current Value Figure 4 7 Profile e The profile dialog displays the following Distance distance between two points Start Point start point coordinate End Point end point coordinate Min minimum value Max maximum value Mean mean value Pixel Value value of mouse clicked point VV ON ON ON WV