80 T1 120Mbps Digital Access Cross Connect Switch

image

Contents

1. channels to full T1 channels The VCL MX Version 6 DXC 80 T1 120Mbps Digital Access Cross Connect Switch occupies IIIIIIIIIIII 6U high 264 mm rack space and is a complete 19 inch standalone unit that provides a 64Kbps time slot DS 0 cross connect fabric for up to 80 T1 ports This product offers 1 1 48V DC Power Supply Redundancy 1 1 Control Card and Processor Redundancy 1 1 Cross Connect TSI Redundancy 1 1 Timing Synchronization Clock Circuitry Redundancy This DXC offers user selectable clock timing synchronization priority The Dual Power Inputs allow the equipment to be powered from two separate power sources AC input external adapter is an optional for AC mains operation Key Features and Highlights e 120Mbps 80 T1 fully non blocking cross connect at 64Kbps DS 0 level 1920 DS 0 any to any time slot cross connect Scalable from 8 T1 Ports to 80 T1 Ports 1 1 Control Card Processor Redundancy 1 1 Cross Connect TSI Redundancy 1 1 Timing Synchronization Clock Redundancy 1 1 48V DC Power Supply Redundancy Dual Power Input allows the equipment to be powered from two separate 48V DC sources Bit Error Rate BER monitoring BER thresholds to generate BER alarms automatically whenever alarm limits are exceeded Telnet remote access SSH for secured remote access SNMP traps Maintains Access Security Log USB and RS232 Interface for local connection through the serial interface to the Net
2. 2PP 19 Metal case 1U High Rack Mount Version with Hardware Set 48xE1 T1 DB37 6 x DB37F to RJ45 48 x RJ45F 3 VCL 1505 TER Termination Panel 1 DB37F RJ45F 48PP 19 Metal case 1U High Rack Mount Version with Hardware Set 4 VCL HRNS 1264 E1 T1 4 Port Connectorized Cable DB25M Open 0 4E10 1 cable each 4 Port E1 T1 card VCL HRNS 1268 E1 T1 8 Port Y Connectorized Cable 2xDB25M DB37M 5 16E1Y37M 1 cable each 8 Port 10 VCL 1505 TER DB37F RJ45F 16PP System Core Cables Installation Accessories 6 UMIKitMXV6DXC Documentation System User Manual Systems User 1 Manual Disk etc Set Technical specifications are subjects to changes without notice Revision 1 1 May 24 2012 Headquarters Phoenix Arizona Orion Telecom Networks Inc 20100 N 51stAve Suite B240 Glendale AZ 85308 Phone 1 480 816 8672 Fax 1 480 816 0115 E mail sales oriontelecom com Website http www oriontelecom com Regional Office Miami Florida Orion Telecom Networks Inc 4000 Ponce de Leon Blvd Suite 470 Coral Gables FL 33146 U S A Phone 1 305 777 0419 Fax 1 305 777 0201 E mail sales oriontelecom com Website http www oriontelecom com Orion Telecom Networks Inc 2012 11
3. 8 T1 Ports to 80 T1 Ports 120Mbps The VCL MX Version 6 DXC has a multi slot chassis with TDM backplane In the chassis there are ten 10 T1 interface card slots Each T1 Interface Card has 8 T1 Ports Two slots are reserved for 1 1 redundant control cards which includes the redundant cross connect processor TSI and clock synchronization timing functions One dedicated slot exists for an OAM card and two slots for 1 1 redundant power supply cards Chassis System Backplane All connections are made at the rear of the chassis providing interconnections between the various plug in cards and to the network VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch supports high density T1 interface cards An extensive set of alarms for easy maintenance are provided in the system Timing Clock Synchronization Internal Clock Loop Timed Clock External Clock User selectable Timing Options synchronization priority Internal Clock span clock timing derived from incoming T1 links Synchronization Sources Loop Timed External Clock 75 Ohms TTL 1 544 Mbps 100 Ohms Bits clock Default Option Internal Clock Orion Telecom Networks Inc 2012 5 VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch System Management VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch offers a variety of management options The equipment may be configured using CLI Engl
4. N TELECOM NETWORKS ORION TELECOM NETWORKS INC VCL MX Version 6 DXC 80 T1 120Mbps Digital Access Cross Connect Switch System Guide Headquarters Phoenix Arizona Regional Office Miami Florida Orion Telecom Networks Inc Orion Telecom Networks Inc 20100 N 51stAve Suite B240 4000 Ponce de Leon Blvd Suite 470 Glendale AZ 85308 Coral Gables FL 33146 U S A Phone 1 480 816 8672 Phone 1 305 777 0419 Fax 1 480 816 0115 Fax 1 305 777 0201 E mail sales oriontelecom com E mail sales oriontelecom com Website http www oriontelecom com Website http www oriontelecom com Orion Telecom Networks Inc 2012 1 VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch Warranty This Orion product is warranted against defects in material and workmanship for a period of one year from the date of shipment During the warranty period Orion will at its discretion either repair or replace products which prove to be defective For warranty service or repair this product must be returned to a service facility designated by Orion The buyer shall prepay shipping charges to Orion and the company shall pay shipping charges to return the product to the buyer However the buyer shall pay all the shipping charges duties and taxes for products returned to Orion from another country Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by th
5. e buyer The buyer supplied firmware or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation or maintenance Exclusive Remedies The remedies provided herein are the buyer s sole and exclusive remedies Orion shall not be liable for any direct indirect special incidental or consequential damages whether based on contract or any legal theory Notice This manual contains information that is proprietary to Orion Telecom Networks Inc No part of this publication may be reproduced in any form whatsoever without prior written approval by Orion Telecom Networks Inc Safety Warnings The exclamation point within a triangle is intended to warn the operator or service personnel of operation and maintenance factors relating to the product and its operating environment which could pose a safety hazard Always observe standard safety precautions during installation operation and maintenance of this product Only qualified and authorized service personnel should carry out adjustment maintenance or repairs to this instrument No adjustment maintenance or repairs should be performed by either the operator or the user UALITY ASSURANCE PROGRAM Orion s products are designed and manufactures under a sinad Quality Assurance Program based on the SO 9001 2008 philosophy and principles Orion pays very special altemtion to ils vendor developenent program whic
6. h ensures an end product of the highest qualily at the most cost eflective prices Orion Telecom Networks Inc 2012 2 VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch Index S No Particulars Page No 1 Product Overview 4 2 Key Features and Highlights 4 3 System Access Control and Management Options 4 4 OAM Operation and Management Ports 5 5 Security and Protection 5 6 System Overview and Architectural Details 5 7 Chassis System Backplane 5 8 Timing Clock Synchronization 5 9 System Management 6 10 Status Monitoring 7 11 Alarm Status and Monitoring 7 12 LED Indication 7 13 External Alarm 7 14 Technical Specifications 7 15 Control Card 7 16 OAM Management Interface Card 8 17 T1 Interface Card 8 18 Power Supply Card 9 19 Power Consumption 9 20 Environmental 9 21 Dimensions 9 22 Ordering Information 10 23 Support 11 Orion Telecom Networks Inc 2012 VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch Product Overview The VCL MX Version 6 DXC 80 T1 120Mbps Digital Access Cross Connect is a modular switch which may be scaled from 8 T1 Ports to up to 80 i i 1 1 i j T1 Ports The VCL MX Version 6 T1 DACS T1 DXC offers full cross connect functionality to cross connect between 64Kbps time slots DS Os n x64Kbps consecutive DS Os and Fractional T1
7. ish text commands or a GUI Graphical User Interface The management and configuration commands may be executed from a VT100 terminal Windows HyperTerminal any DOS based system Linux or UNIX based system or Telnet remote configuration and management Control Card 1 Master 10 Nos x 8 T1 Interface Card Power OAM Unused Supply 1 Card Slot Power Unused Control Supply 2 Slot Card 2 Slave The equipment provides a wide choice of access ports for connecting to and executing management and configuration commands through its OAM Card The OAM card provides a COM Port RS232 Serial Port b USB Port c 10 100BaseT Ethernet Port each multiplexer may be assigned an IP address and connected to a LAN IP network for remote access and management through the 10 100BaseT Ethernet Port for out of band configuration management and access Orion Telecom Networks Inc 2012 6 VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch The OAM card supports Telnet SSH SNMP V2 Additionally a Windows based GUI Graphical User Interface for easy configuration management and access aq 08 The VCL MX has an effective CLI text and GUI based Network Management Interface which may be used for configuring and monitoring multiple systems from a single central location Status Monitoring Synchronization Clock Selection Status of alarms Enabled Disabled status of 1 544 Mbps T1 port
8. n a unique IP address to each multiplexer connected in a LAN to be managed from a single point Telnet SNMP V2 VCL MX 1506 19 Shelf 6U High Sub rack fitted with DB25F Connectorized Backplane Max Ten 10 traffic slots meant for tributary cards line cards VCL MX 1510 48VDC Input Power Supply Card may be used in a 1 1 redundant Configuration Note Please order 2 numbers for 1 1 redundancy VCL MX Version 6 Upto 80 T1 120Mbps DACS DXC User Configurable Interfaces Sr No Part Number Product Description Qty VCL MX 1520 T1 5 0 8 T1 Interface Card Full capability to cross connect at DS 0 64Kbps time slot level as well as to inter connect to voice and digital data services between 80 incoming T1 Ports i e 80 separate T1 Links 1920 DS 0 any to any time slot cross connect 10 Cards 80 Ports Max per Chassis 10 Orion Telecom Networks Inc 2012 10 VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch VCL MX Version 6 Upto 80 T1 120Mbps DACS DXC Cables amp Accessories Sr No Part Number Product Description Qty 16xE1 T1 DB37 2 x DB37F to RJ45 16 x RJ45F 1 VCL 1505 TER Termination Panel 0 DB37F RJ45F 16PP 19 Metal case 1U High Rack Mount Version with Hardware Set 32xE1 T1 DB37 4 x DB37F to RJ45 32 x RJ45F 2 VCL 1505 TER Termination Panel 1 DB37F RJ45F 3
9. nnect at DS 0 64Kbps time slot level as well as to inter connect to voice and digital data services between 80 incoming T1 Ports i e 80 separate T1 Links 1920 DS 0 any to any time slot cross connect Number of Interfaces per T1 Interface Card 8 T1 Interfaces with full capability to cross connect at DS 0 64Kbps time slot level as well as to inter connect to voice and digital data services between 80 incoming T1 Ports i e 80 separate T1 Links Connectors DB 25 RJ 45 RJ 48C Conformity electrical ITU T G 703 Frame Structure As per ITU CCITT G 704 Framing Options D4 ESF Selectable Line Coding AMI B8ZS Selectable Line Rate 1 544 Kbps 50 ppm Nominal Impedance 100 Ohms Jitter Tolerance ITU T G 823 ITU T 1 431 Monitoring Connection Line Quality Loss of Signal LOS Loss of Frame LOF All Ones Alarms AIS RA Remote Alarm Orion Telecom Networks Inc 2012 VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch Power Supply Part No VCL MX 1510 Input DC Voltage 48V DC nominal Range of Input 36V to 72V DC Output Voltage 5V filtered 48V for terminal cards Full Load Current Rating 4A at 48V DC Input Voltage Reversal Protection Provided in the Card Over Current Protection 4A at 48V DC Short Circuit Protection Current limit 4A Recovers on removal of sh
10. ort Efficiency at Full Load gt 91 Power Consumption Maximum Power Consumption 90 watts Environmental Temperature 10 C to 60 C Humidity 95 R H non condensing Altitude Upto 9 000 feet Dimensions Height 266 mm 19 6U high Width 482 mm Depth 270 mm Weight 7 Kgs Regulation Compliance Meets CE requirements Safety ULI 1459 Issue 2 Protection Complies with FCC Part 68 and EMC FCC Part 15 Class 2 Operation ETS 300 019 Class 3 2 Storage ETS 300 019 Class 1 2 Transportation ETS 300 019 Class 2 3 Central Office Terminal and Remote Terminal are protected against power surges and transients occurring from lightning and electric induction as per CCITT Rec Table I K 20 towards line side Orion Telecom Networks Inc 2012 VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch Ordering Information VCL MX Version 6 Upto 80 T1 120Mbps DACS DXC Core Common Equipment Sr No Part Number Product Description Qty VCL MX 1500 DXC DACS Control Card Central processor cross connect and system control Card may be used in a 1 1 redundant Configuration Note Please order 2 numbers for 1 1 redundancy VCL OAM 1490 5 0 Management Card RJ45 DB9F COM USB OAM Operations and Management Card for connecting the multiplexer to be managed in a LAN allows the USER to assig
11. s Monitoring the 80 Port T1 DACS status and configuration Monitoring of T1 Link status LOS LOF AIS RA Alarm status and monitoring e Loss of incoming signal at all 1 544 Mbps T1 Ports e Configuration error alarm LED indications 1 to 80 T1 Ports LED indicators 5V DC present 48V DC present Configuration error External Alarm Contact Closures e 1 Alarm relay Type form C Technical Specifications DACS Control Card Processor Timing and TSI Card Part No VCL MX 1500 DXC Control Card Redundancy Yes 1 1 Redundant ARM7 Self Learning Processor i Self Healing Automatic Fail Over and Recovery 1 1 Redundant Timing and TSI ET emng Self Healing Automatic Fail Over and Recovery Orion Telecom Networks Inc 2012 7 VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch OAM Management Interface Card Part No VCL OAM 1490 5 0 e COM Port RS232 Serial Port e USB Port e 10 100BaseT Ethernet Port Each multiplexer may be assigned an IP address and connected to a LAN IP network for remote access and management through the 10 100BaseT Ethernet Port for out of band configuration management and access Telnet SSH SNMP V2 access Windows based GUI Graphical User Interface for easy configuration management and T1 Interface Card Part No VCL MX 1520 T1 5 0 Maximum number of interfaces 80 T1 Interfaces with full capability to cross co
12. work Control and Management Software User Selectable Internal External and Loop timed clock synchronization priority options e Local and remote loopback facility System Access Control and Management Options Telnet SSH CLI Control Interface HyperTerminal or VT100 SNMP V2 Traps MIB File provided GUI Graphical User Interface Orion Telecom Networks Inc 2012 4 VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch OAM Operation and Management Ports e RS232 Serial Port e USB COM Port e 10 100BaseT Ethernet for remote access Security and Protection e Secured Access via SSH V2 e Password Protection Password Protection in compliance with the mandatory clauses of the GR 815 CORE 2 specifications for secured access control e Logging Maintains a log of all successful and un successful attempts Logged information includes the ID and the IP address of the accessing entities Alerts the administrator if the un successful logging attempts exceed 3 e Security Audit All access logs for up to 30 days are maintained for security audit purposes e Security log entry of any request or activity including that user ID including IP address if applicable to establish user accountability e Report Generation Audit Trail e Security Administration System Overview and Architectural Details VCL MX Version 6 is a scalable DXC which may be used to cross connect at DS 0 64Kbps time slot level from

Download Pdf Manuals

image

Related Search

Related Contents

Web article  Samsung MS23F301EAW Felhasználói kézikönyv  IM1202 小型真空ゲージ付バルブ 表 (ver10_code no IM0230).eps  Toastmaster TG21WCAN User's Manual  Guía de inicio rápido inalámbrico  TomTom Urban Rider TomTom Rider Pro  Oceanic OCS - naturzeit Wassersport  228-6002-01 - Nordic BioSite  RCS-2 Programmers Manual  Samsung DVD-P346 User Manual  