        EUROSTER 11K
         Contents
1.   f  Detection of sensor failures and other dangerous situations    a events are recognized shia the controller     Pumps  AUX output __  Acoustic signal   ae Te  Deep freeze  ree   eee  control algorithm    Critical temperature exceeded   Temperature  on   off    Alarm temperature exceeded _ temperature exceeded Terperatre on  or   yes  Overheating             4    Strong EA    Each of the above events          e cancels ignition function  if activated   e starts to blink controller screen contents     In case of a single error of the S1 S2 sensor  the i    Y light is lit  respectively  In case of  more than one simultaneous errors  only the highest priority error is signaled  Error priorities       e Si sensor failed  SH or OP    S2 sensor failed  SH or OP    S1 sensor overheated or frozen  LO or Hi   S2 sensor overheated or frozen  LO or Hi   Si sensor temperature too high     S2 sensor temperature too high     g  Alarm output  optional     In case of an alarm all pump outputs  including outputs not used in the given system layout   are activated  It means that each unused pump output may be used as an alarm Signal    The P3 output is equipped with both normally open  NO  and normally closed  NC  contacts   In case of an alarm  mains voltage normally connected to the NC contact is switched over to  the NO contact     h  Acoustic alarm    Should the fireplace water jacket CH tank temperature exceed the alarm threshold  an  acoustic alarm signal is activated  Press any butto
2.  Therefore the parameters should be modified  exclusively by a qualified installer serviceman     Simultaneously press and hold the and buttons to enter the service setup mode  Code   symbol  of the first installer parameter is displayed  Use the 4  and    buttons to display  other parameters  Use the     button to display current value of the displayed parameter  Use  the 4  and 3 buttons to modify the displayed value  Each modification must be confirmed    with the puton or else the controller will cancel it after 1 minute  Use the x  button to  cancel errors    Installer parameters  system settings that should be modified only by a qualified  installer serviceman  include     e Hi Pi threshold hysteresis   i e  difference between temperature at which the Pi  pump is engaged and temperature at which the pump is disengaged   Range   1 10  C  Standard value  5  C    H2 P2 threshold hysteresis  Range  1 10  C  Standard value  5  C    H3 P3 threshold hysteresis  Range  1 10  C  Standard value  5  C    HP Throttle threshold hysteresis  Range  1 10  C  Standard value  5  C    HA AUX output threshold hysteresis  Range  1 10  C  Standard value  5  C    tE Put out temperature  Range  30  40 or tb 10   C  Standard value  30  C     EUROSTER 11K CONTROLLER USER MANUAL 8    tb    OH    AL    dF    OF    C1    C2  SC    Pr    t1    t2  t3  tP  tA    Controller treats the fireplace as shut down and closes its throttle if the fireplace  temperature has dropped down below tE  On the other h
3.  for 30 seconds  To that end the controller  must be left powered up     EUROSTER 11K CONTROLLER USER MANUAL 2    2  VISIBLE CONTROLLER ELEMENTS       Lights Light ON means    1      ignition function ON   2      1 2  sensor temperature reading displayed  3   alternative heat source ON   4      2      1   2     3  pump ON   5   D       throttle open   6    room thermostat signal hooked up   Z        controller power ON    Button functions    l  x      exit  cancel  turn the controller off   2       decrement the displayed value  turn the ignition off   J          increment the displayed value  turn the ignition on   4         accept the displayed value  turn the controller on  enter the setup mode     3  INSTALLATION    ATTENTION Hazardous voltages may be present inside the controller and  on its cables  Therefore it is expressly forbidden to install the device unless  its mains power supply is disconnected  Only qualified technicians may  install the controller  Do not install any device showing signs of any  mechanical damage     EUROSTER 11K CONTROLLER USER MANUAL 3    Controller terminals     Mains Throttle    P1 P2 P3 AUX  230 V actuator 230 V   230 V 230 V  230 V     T  S 8 S a  8 2   Zlo 00  So Biat 2 aail JZ la CB   AAIE   a    Onne aja    YY    ATTENTION The controller must not be installed in a place where ambient  temperature may exceed 40  C        Room  thermostat   S2  sensor   S1  sensor    ATTENTION The controller is equipped with an electronic power supply  s
4. EUROSTER 11K CONTROLLER USER MANUAL 1    EUROSTER 11K       CEKO    MANUFACTURER  P H P U  AS  Polanka 8a 3  61 131 Pozna    POLAND    1  FIELD OF APPLICATION  EUROSTER 11K universal controller for water jacket fireplace central heating systems is  equipped with switched 230 VAC outputs to connect the following system elements        electrically controlled actuator of the fireplace combustion air throttle  plate heat exchanger water circulation pump   CH  central heating  system water circulation buffer tank pump   DWH  domestic hot water  tank pump   and universal voltage free contacts that may be used to turn on off        alternative heat source  e g  a gas fired boiler      The controller may control systems built according to one of the three following layouts       CH system with a plate heat exchanger    e CH system with a heat buffer    CH system with a plate heat exchanger and a DWH tank     In all layouts the controller adjusts the combustion processes by opening closing the fireplace  throttle depending on the measured temperatures and information received from the  cooperating room thermostat  An alternative heat source  e g  a gas fired boiler  may also be  turned on depending on the temperatures and the information     STOP          The EUROSTER 11K controller features the ANTY STOP function that prevents idle pump  rotors and valves against seizing  Once the heating season is over  every 14 days the function  will automatically turn the pumps and the valves on
5. and the controller  resumes normal operation after the ignition phase as soon as the temperature  has risen above tE  If the put out temperature is set too high  the fireplace  might be put out by the controller  If the put out temperature is set too low  the  throttle might be opened unnecessarily    Standby temperature  Range  40  60 or OH 5   C  Standard value  45  C   Controller maintains that temperature while there is no demand for heat  The  parameter should be set for a minimum temperature at which fire at the  fireplace can be sustained    Critical temperature  Range  60  90 or AL 1   C  Standard value  80  C  As soon  as the fireplace temperature has exceeded that threshold  the controller starts  emergency cool down procedure  throttle is closed and all available pumps are  engaged    Alarm temperature  Range  85 95  C  Standard value  90  C  Should the  fireplace temperature exceed that threshold  acoustic warning signal is activated   Minimum difference between temperature of the fireplace and temperature of  the CH tank buffer at which the tank buffer is loaded  Range  1 20  C  Standard  value  5  C    Automatic controller activation  Range  0 1  Standard value  1    On 0  the controller will not activate until the fireplace temperature rises above  the OH threshold    On 1  the controller will activate as soon as the fireplace temperature exceeds  the tE threshold    Automatic shut down delay  Range  0 30 min  Standard value  5 min  The  controller will shut do
6. arameters may be used to manually turn on off the P1  P2   P3 pumps  throttle  and AUX outputs  respectively  to test them      5  SETUP  a  User parameters  User parameters are system settings  temperature presets  that may be modified by the user     Use the    button to sequentially display preset temperature thresholds at which P1 P2 P3  pump  throttle  and AUX output are activated  press the button to display next preset   Use    the    and     buttons to modify the displayed value  Each modification must be confirmed    with theO button or else the controller cancels it after 10 seconds  Use the x  button to  cancel errors    Only user parameters used in the given system layout are displayed  those not used are  hidden  User parameters include     e Pi Temperature at which the P1 pump is engaged  Range  20 85  C  Standard  value  40  C    e P2 Temperature at which the P2 pump is engaged  Range  20 85  C  Standard  value  40  C  Only for layouts 2 and 3    e P3 Temperature at which the P3 pump is engaged  Range  20 85  C  Standard    value  45  C  Only for layouts 2 and 3       THROTTLE Preset fireplace temperature  throttle activation threshold   Range   20 or  tb   70 or OH 5  C   Standard value  55  C    e AUX Temperature at which the AUX output is deactivated  Range  20 85  C   Standard value  35  C     b  Installer parameters  service mode settings     ATTENTION Installer parameters must be modified knowledgeably or else the CH  system may start to work incorrectly 
7. erate exclusively with room thermostats equipped with voltage   free normally open  NO  output contacts       link E11K controller box with room thermostat box  or its receiver in case of a wireless  remote control  using at least 2 x 0 75 mm  braided cord       connect a cable to the RT terminals of the E11K controller    e connect the cable to the COM and NO thermostat terminals   e  Connect pumps throttle actuator        connect blue wire to the N terminal     e connect brown wire to the L terminal     e pumps must be hooked up to the P1 P3 controller terminals  respectively      throttle actuator must be hooked up to the throttle output N and L open or L close  controller terminals  depending on the type of the throttle     ATTENTION The controller may cooperate exclusively with a bi state  throttle actuated by a 230 VAC actuator  In absence of power the  throttle should close automatically       e connect protective wires of the pumps and of the throttle with the PE power cord wire     ATTENTION Controller is a 2  insulation class device  so it needs no  grounding  However  every cooperating device that needs to be  grounded must be obligatorily connected to the protective wire     f  Hook up power supply cable       e connect neutral  blue  wire to the N terminal     connect live  brown  wire to the L terminal     g  Verify the connections     check up all cable connections and tighten the terminal box lids   h  Mount the controller      carefully put the controller boa
8. her party clearly  authorized by the manufacturer    5  Warranty becomes invalidated in case of any mechanical damage  incorrect operation  and or making any repairs by unauthorized persons    6  This consumer warranty does not exclude  restrict nor suspend any right of the Buyer  ensuing if the product would not meet any of the sale contract terms     sale date serial number date of manufacture signature stamp    Business entity that issued this warranty certificate   P H P U  AS Agnieszka Szymanska Kaczynska  Chumietki 4  63 840 Krobia  Poland    
9. higher than the heat buffer temperature   P2 pump is activated if the buffer temperature exceeds the preset temperature and the  RT signal is ON   P3 alarm output is activated if the fireplace temperature exceeds the critical  temperature   AUX output is deactivated if the heat buffer temperature exceeds the AUX temperature  or RT is turned off   Throttle is controlled  open closed  to maintain the preset temperature     EUROSTER 11K CONTROLLER USER MANUAL 10    c  Layout 3   CH system with plate heat exchanger and DWH tank  32       RT       THROTTLE    tank  temperature of water in that tank may theoretically reach the critical    j ATTENTION Since in the 3  layout heat surplus is transferred to the DWH  threshold  as preset by the OH installer parameter value        Pi pump is activated if the fireplace temperature exceeds the preset temperature   e P2 pump is activated if the fireplace temperature exceeds the preset temperature and  the RT signal is ON and the DWH priority is not active   e P3 pump is activated if the tank temperature drops down and the fireplace temperature  is sufficiently higher than the tank temperature   e AUX output is deactivated if the fireplace temperature exceeds the AUX temperature or  RT is turned off      Throttle is controlled  open closed  to maintain the preset temperature     7  COMPATIBILITY WITH STANDARDS AND CERTIFICATES    The E11K controller meets all requirements of the EMC and the LVD EU Directives  The CE  Conformity Declaration i
10. n to stop the signal for 5 minutes     i  The ANTY STOP function    The ANTY STOP function turns the CH system pump s  on every 14 days for 30 s  to prevent  rotor seizing    AS  letters are blinking on the controller display while the function is active     j  DWH priority    In CH systems with DWH tanks the DWH function may be assigned a higher priority than the  CH function  If this is the case  the controller will turn the CH system off should heating of  DHW be needed  to shorten time necessary to heat the DHW tank up   A modified DHW  priority function implemented in E11K controllers prevents room temperature to drop down too  much while the DHW tank is heated  every now and then  preset period  the function is turned  off for 10 minutes so that the CH pump may be turned on for that time    The DHW function period may be set as the Pr installer parameter value  For example if Pr    30  the DWH priority function will be suspended and the CH pump turned on every 30 minutes   for 10 minutes   The Pr   O value disables the DWH priority function  which means that the  CH pump will operate regardless of the DHW tank temperature     EUROSTER 11K CONTROLLER USER MANUAL 7    k  Relay activation delay    To increase lifetime of the controller output relays  outputs are prevented against activating   deactivating more frequently than once per second  However  lights signaling state of the  relays go on off without any delay     I  Output tests    The t1  t2  t3  tP  Ta installer p
11. rces    Controller may cooperate with a room thermostat and an alternative heat source  e g  a gas   fired boiler   To that end it is equipped with the RT input for signals from the room thermostat  and the AUX output to control the alternative heat source    If voltage free contacts hooked up to the RT input are closed  fireplace is heated up to the  preset throttle activation temperature and the CH pump is turned on  Should the contacts  become open  fireplace temperature will be lowered to the preset standby temperature  and  the CH pump will be turned off  provided that is possible in the given system layout   Surplus  of the produced heat will be stored in the CH tank     AN ATTENTION Only room thermostats equipped with voltage free output  contacts may be hooked up to the RT input of the controller     To turn the alternative heat source on  the controller closes the COM and NO contacts of the    AUX output  which is signaled by the Ry light  Contacts of the AUX output are voltage free   The alternative heat source is turned off when        the fire place is hot     the RT input is open     Provided that power supply is present  state of the AUX controller output does not depend on  the controller mode of operation  including controller shut down  Besides  the normally closed  AUX output contacts enable operation of the alternative heat source even if the E11K    EUROSTER 11K CONTROLLER USER MANUAL 6    controller its sensor fails or in case of a power supply black out 
12. rd into its box  fix the box  and put the front cover on   4  OPERATION  a  Turning the controller on off    Press the     button to turn the controller on  Firmware version number is displayed  the  ANTY STOP function is executed for 30 s  then the device resumes normal operation     Press and hold the x  button for 2 seconds to turn the controller off  Device screen turns blank     only the O light remains lit  and the throttle closes so that the fireplace goes out  Control  algorithms will continue to run in order to fully utilize the produced heat and to provide  fireplace safety    The controller turns off automatically if the water jacket temperature exceeds the put out  temperature  The function is active if the On installer parameter has been set to 1  If the  parameter has been set to 0  the controller will not turn off until the temperature exceeds the    EUROSTER 11K CONTROLLER USER MANUAL 5    warning  critical  temperature    The controller also turns off automatically should the fireplace went out  It will happen after  the time  in minutes  set as the value of the OF installer parameter  If the parameter is set to  0  automatic controller shut down is disabled     b  Reading states of outputs and temperatures    Activation of a controller output is signaled by front panel light assigned to that output  see  description in the VISIBLE CONTROLLER ELEMENTS section above  By default  the S1 sensor    temperature is displayed on the controller screen  Press the Z bu
13. s available on the http   www euroster com pl Internet webpage     8  SPECIFICATIONS    a  Temperature range 0  C   99  C   b  Mains 230 V 50 Hz   c  Combined current consumption max  3A   d  Case flush fitting 4M electrical box    4  KIT CONTENTS    a  Euroster 11K controller   b  S1 temperature sensor with 2 m long silicone insulated cable  c  S2 temperature sensor with 2 5 m long cable   d  sensor hose clips   e  this Installation  amp  Operation Manual    ELECTRONIC WASTE MANAGEMENT INFORMATION    We made every effort to get as long controller lifetime as possible  However   the device is subject to natural tear and wear  We ask you to have a  controller that will not meet your requirements any more brought into an  electronic waste management facility  Electronic waste is collected free of  charge by local distributors of electronic equipment     Inappropriate management of electronic waste may lead to an unnecessary  environment pollution        Cardboard boxes should be disposed of at a paper recycling facility     EUROSTER 11K CONTROLLER USER MANUAL 11    GUARANTEE CERTIFICATE  EUROSTER 11K    Warranty terms    1  Warranty is valid for 24 months from the controller sale date    2  Claimed controller together with this warranty certificate must be supplied to the seller    3  Warranty claims shall be processed within 14 business days from the date the  manufacturer has received the claimed device    4  Controller may be repaired exclusively by the manufacturer or by ot
14. tton to display the other    sensor reading  if the S2 sensor is available in the system   At any time the Cand Ge lights  Signal which sensor temperature is currently displayed  S1 or S2   Temperatures lower than  0  C are displayed as LO  temperatures higher than 99  C are displayed as Hi     c  Throttle control    The controller opens the throttle if fireplace jacket water temperature is too low  and closes  the throttle if the temperature approaches the jacket preset temperature  The preset depends  both on user settings and on room thermostat  RT  signal     e If the RT input is short circuited  the temperature set as the throttle user parameter  value is maintained   e If the RT input is open  the temperature set as the tb installer parameter value is  maintained     d  Ignition    The ignition function consists in keeping the throttle open until the fireplace gets lighted as  signaled by increase of the fireplace temperature above the put out threshold  defined as the  tE installer parameter value   Should that not happen within 1 hour  the controller will cancel  the ignition function and close the throttle  Otherwise it will resume normal operation        amp     Activation of the ignition function is signaled by the WY light  The function is activated  automatically once the controller is turned on  It may also be activated manually using the  button  Press the    button to deactivate the ignition function    e  Cooperation with room thermostats alternative heat sou
15. witch  which does not guarantee safe isolation of power in all  circumstances  In particular  if some sensor wires are disconnected or  short circuited during assembly works  hazardous voltages may appear on  some controller outputs  Therefore the controller power supply cord must  be unplugged before any works are started     The procedure   a  Mount the S1 sensor       do not immerse the sensor into any liquid nor install it within chimney flue gas stream    install sensor at some external surface of the fireplace water jacket or on an uncovered  segment of the fireplace outlet pipe  as close to the fireplace as possible      using a hose clip tighten the sensor to its pipe   b  Mount the S2 sensor  if used      do not immerse the sensor into any liquid nor install it within chimney flue gas stream      depending on the selected layout install the sensor on the heat buffer DWH tank    e using a hose clip tighten the sensor to its pipe     EUROSTER 11K CONTROLLER USER MANUAL 4    c  Connect additional heat source controller        unplug additional heat source controller from its power supply       link E11K controller box with alternative heat source controller box using at least 2 x  0 75 mm    braided cord      e connect a cable to the AUX output COM and NC or NO terminals of the E11K controller   depending on the type of the alternative heat source      connect the cable to the alternative heat source controller     d  Connect room thermostat      the controller may coop
16. wn automatically OF minutes after the time when the  fireplace temperature has dropped down below the tE threshold    OF 0  the controller will never shut down automatically    S1 sensor offset  Range   5 5  C  Standard value  0  C  That parameter may be  used to correct temperature readings    S2 sensor offset  Range   5 5  C  Standard value  0  C    CH system layout  Range  1 3  Standard value  1    SC 1  heat exchanger  2 pumps  the simplest layout    SC 2  heat buffer  2 pumps   SC 3  DWH tank  heat exchanger  3 pumps    See detailed description in the SYSTEM LAYOUT section below    DHW priority suspend period  Range  0 90 min  Standard value  O min    Pr 0  DHW priority disabled  CH and DHW pumps operate independently   Pr 30 60 90  DWH priority function will be suspended and the CH pump turned  on every 30 60 90 minutes for 10 minutes to prevent room temperature against  dropping down too much while the DHW tank is heated    Pi output state  Range  0 1    ti   0  the output is inactive   ti   1  the output is activated   P2 output state  Range  0 1   PS output state  Range  0 1   THROTTLE output state  Range  0 1   AUX output state  Range  0 1    c  Automatic verification of settings    The controller verifies the entered presets and automatically corrects settings which would  prevent its correct operation  This is accomplished two ways     If the modified setting is a key parameter on which other less important parameters  depend  the entered modification automaticall
17. y forces respective modification of all  dependent parameters  For example  if the alarm temperature is lowered  throttle  activation temperature is also automatically lowered     EUROSTER 11K CONTROLLER USER MANUAL 9    If the modified setting depends on another more important  key  parameter  the  system will prevent any incorrect modification  For example  the throttle activation  temperature may not be set higher than the alarm temperature     6  SYSTEM LAYOUTS    Use the SC service parameter to select the actual system layout  The below shown diagrams  are simplified  not all elements necessary for correct operation of the system are shown   Legend     S1  S2 1  2   temperature sensor  RT room thermostat   P1  P2  P3 1  2 1 3  pump  THROTTLE combustion air throttle    a  Layout 1  CH system with plate heat exchanger       THROTTLE    P1 pump is activated if the fireplace temperature exceeds the preset temperature   P2 pump is activated with a delay in respect to P1 activation time if the fireplace  temperature exceeds the preset temperature   P3 alarm output is activated if the fireplace temperature exceeds the critical  temperature   AUX output is deactivated if the fireplace temperature exceeds the AUX temperature or  RT is turned off   Throttle is controlled  open closed  to maintain the preset temperature     b  Layout 2  CH system with heat buffer       THROTTLE    Pi pump is activated if the fireplace temperature exceeds the preset temperature and  is sufficiently 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
取扱説明書 - 山田照明  Advanced Link Manager User Guide  JERG-2-142 一般環境標準 - 安全・信頼性推進部  詳細情報  MicroMaxx® Ultrasound System User Guide Supplement 3 (14 LGs)  Calligaris Flat  Horizon Navigation NavMate Car GPS Receiver User's Manual  0800/3450000 Österreich und der Schweiz: 008000  70022_DE - Lidl Service Website  Moxa Proactive Monitoring User`s Manual    Copyright © All rights reserved. 