Contents

1. 2 4 1 TPC 1271H LCD panel TFT LCD LED 12 1 touch panel is compatible with IP65 The panel allows one to display the visualization of vibration estimates presented in the VIBmonitor manager software RMS PP Kurtosis RMS envelope Envelope RMS Additionally the panel allows one to visualize the settings and exceeding of alert thresholds It is also possible to configure Level of alarm thresholds warning alarm State of relay outputs with respect to the thresholds 2 4 1 1 Technical data Technical parameters are included in the accompanying specification of the module 2 4 2 VIBair SB The module enabling connectivity to wireless sensors VIBair and their integration with VIBmonitor system 2 4 3 VIBair sensor Wireless vibration sensor is compatible with VIBmonitor by VIBair SB module The basic specification of the VIBair sensor is as follows 1 2 directions of vibration measurement Frequency 10kHz Built in analysis gt aRMS gt aPEAK gt Crest Factor gt VRMS gt Envelope RMS gt FFT Temperature measurement str 27 VIBMONITOR USER MANUAL EQ 2 5 Powering the system VIBmonitor system requires power supply of 24 V DC Power supply should be connected only to the processing module and server module Other parts are powered by internal bus interface It is necessary to provide noise free power supply It is most preferred t
2. Ma pe A asno gt 4 5 T VIBmonitor USER MANUAL EL systems VIBMONITOR USER MANUAL YU Table of content JI NOC UNO Maia vad E a a ea E E E E E E A ek eh 5 1 1 ON o ee ett je en a ene es 5 1 2 Configuration and handling aa a a oba nj ea eni aa oa na oe tena 5 1 3 NDO S A AE T A E EE sano teaeoease eee 5 1 4 Safety ee A A A A A A A A RE A NE EEA A A EEA RE EVA AR A A MARE MANE PEU RE AJA 5 1 5 important recommendations size a o a a A aa a k aa iii 5 1 6 Electrostatic discharge a A Er AE NE IE ME RE A AE ER REN 6 Z VE DINONILO S STEM an a a a NA o aa a a ANN a a ae a O aa aaa 7 2 1 Purpose ofthe SYS nt hacer ceases anaE EEE ASSA S 7 2 2 ViBmonitor Ele STNO UTE ae aloje oja E T onalni 7 Fe Bk OO NC ea E a a A E 8 2 2 2 VM PC5100 processing MOOUE vna ve ea ai ed pe ninaiona 11 2 2 21 bo EEA EP PEPE VE RENARNE 11 22 Front panel VIEW acces rep a o ae RA a eko a bek 11 DPD CONME AO e E dos cede 11 LALLA es ONI NINA e dee ene ere eee ee mer E E ee 11 LLAS POM STAN e o o a oe ee ee a a ae a aka 12 D220 ea aN a A A E O 12 2 2 3 VMS IOS VO OG UN e E OEE ER 13 Zod DEPUN ee r E veounsatees 13 2232 FONC PINE VIEW cashes scence ea EE E SAA A 13 Loo POWT ee E E EE 14 2 2 3 4 Technical ei A a Ee A A A V A A AE ANE 14 2 2 4 VIMEO EDO Call aa a a a aaa ak ok aa ana 15 LAA A Me so pa A A einen nnd Ri ai ME A a EEA va 15 22A MOOV O N e A A a Vama 15 22A CONIECO Neee S OR ONA 16 2 2 4 4 The parameters of the measuring DAM sni ee a
3. VM PCS100 Server card VM S101 Vibro card VM V4001 In addition the system comes with a software tool VIB monitor manager VIBmonitor EL system is designed for installation in boxes with IP65 standard If the VIBmonitor system is supplied with LCD panel box is provided with glass door IP65 which enables the display of the data presented by the VIBmonitor manager software The main advantages of the VIBmonitor EL system include Advanced diagnostic analysis Parallel processing of analog and digital signals The modular design Signaling LED panels Recording of historical data Measurement resolution of 24bit 100kHz sampling Cooperation with SCADA systems str 7 VIBMONITOR USER MANUAL EQ Control of external systems Access from anywhere in the world Ethernet Support for Modbus and OPC The VIBmonitor EL can be extended by functional cards and peripherals that are presented in Chapters II 3 and Il 4 The modular design of the VIBmonitor system allows any hardware configuration which enables the creation of a system that meets the exact requirements The following chapters present the various elements of the VIBmonitor EL system VIBmonitor system is part of monitoring and diagnostic platform VIBstudio 2 2 1 Base board The base plate VM BP6006 allows to connect one processing card VM PCS100 one server card VM S101 and up to six functional cards S el WY UO VW
4. and DOx 2 120mA the maximum load current 160 maximum resistance Dual state digital input connector gt DI1 and DI2 cold potential connector gt IN DI1 and DI2 IN digital signal input gt DI1 and DI2 hot potential connector gt the parameters 2 digital inputs npn pnp Operating mode 24VDC the maximum voltage between DIx and Dix Analog Input connectors gt AIN1 to AIN4 positive analog input gt AIN1 to AIN4 negative analog input gt the parameters of the analog inputs 4 20mA current input 0 10 VDC voltage input str 20 VIBMONITOR USER MANUAL EQ 2 3 2 3 Configuration Configuration is done by the manufacturer The user is obliged to specify the module operating type according to the formula shown below D NP A I 11 U 4 8 a pulse input channel 4 type 0 10V channel 1 type N channel 1 3 type 4 20mA channel 2 type P analog outputs Module VM P4200 has digital inputs that can operate as an impulse ones It can be configured as NPN or PNP relay outputs and analog inputs that can be configured as current I or voltage U source sink 2 3 2 4 Analog input The 4 20mA input is protected against short circuit and the device is able to detect open circuit The figure below is an example of connecting the transmitter to the 4 20mA input GND 24V NOTE lin 20mA gt Uin 2 6V str 21 VIBMONITOR USER MANUAL YU 2 3 2 5 Digital
5. lt gt server transmission gt 1 to S4 the status of the analog inputs LED blinking no sensor OPEN LED continuous light short channel SHORT LED is not lit the sensor is connected gt PD phase marker ADDR enables setting address depending on the number of the slot where the card has been installed Phase marker connector gt PD phase marker GND gt PDIN phase marker input gt PD power output of the phase marker 24V Analog Input connector gt S1 S4 hot wire of vibration sensor gt 1 to S4 for cold wire of vibration sensor str 15 VIBMONITOR USER MANUAL EQ 2 2 4 3 Configuration VM V4001 module has an phase marker input which can be configured as NPN or PNP Configuration is done by the manufacturer The user is obliged to specify the module operating type NPN or PNP Note One need to set the correct address for each module depending on the slot number position in the base plate Slots must be occupied in turn starting with the slot 0 The VM V4001 cards should be placed closest to server card Optional cards should be placed after VM 4001 cards 2 2 4 4 The parameters of the measuring path Gain x1 x2 x5 x10 Sensor power supply 4mA 20VDC FGP filter cutoff frequency 0 16Hz FDP filter cutoff frequency 12kHz 2 2 4 5 How to connect IEPE sensors The module consists of 4 input channels designed for use with IEPE type vibration sensors
6. 3 Symbols NOTE Information marked with this sign are of particular importance to the safety of the system 1 4 Safety issues NOTE Before performing the installation module replacement setup or wiring switch off the system power supply 1 5 Important recommendations When replacing modules the bus and signal connectors must be protected from dirt and contacts deformed str 5 VIBMONITOR USER MANUAL YU If not all of the slots in the base plate are filled the unused bus connector must be left free It is unacceptable to short circuit the terminals or attaching any devices to unused connectors in the base plate The design of the system enables operating with as many modules as currently positioned correctly on the base plate System components are not resistant to aggressive cleaning agents aerosols alcohols and solvents If necessary dust can be removed with a dry brush and larger dirt with a damp cloth Housings of base plate and individual modules are not resistant to environmental conditions such as moisture and dust If installation in such an environment is necessary the system must be equipped with appropriate housing in the form of cabinets for automation components with an appropriate degree of protection IP The VM BP6006 base plate VM PCS100 processing module and VM S101 server module do not contain any internal regulatory or configuration elements so it is prohibited to open the housing of these modu
7. During installation pay the particular attention to the power plug polarity To connect the sensor with VM V4001 card twisted pair cable should be used in the shield The shield should be tucked into the PE potentials at one point Example of connecting the sensor to the module is shown in the figure below str 16 VIBMONITOR USER MANUAL YU 2 2 4 6 Phase marker input Phase marker s input is connected with 4 vibration input channels It can be configured as NPN or PNP active high or low The connection schemes for both NPN and PNP configurations are shown in the following figures Har 0 7V Ui 15 24V Usan 17 24V Up O 12V NOTE Shorted power supply outputs of phase marker pin 1 and pin 3 may cause permanent damage to the module and the system str 17 VIBMONITOR USER MANUAL YU 2 2 4 7 Technical data VM V4001 vibro card Vibration sensors input type IEPE 24V DC 4 0 mA No Of channels Gain x1 x2 x5 x10 High pass filter 0 16 Hz 12 dB oct Low pass filter 12 kHz 24 dB oct Input status OPEN SHORT OK Channels auto calibration Yes Technical Data Type of a d converter delta sigma Sampling frequency 25kHz 50kHz or 100kHz Resolution 24 bit Internal communication interface RS485 SPI Sensor input connector Eurostyle terminal 3 81 mm Operating Data Mounting Screws in set to the vm bp6006 base plate 2 2 5 VIBmonitor manager software str 18 VIBMONITOR USER MA
8. NUAL EQ 2 3 Extensions of VIBmonitor system functional cards This section provides the information about possible extensions functional cards of VIBmonitor system 2 3 1 VM V4001 vibro card Additional VM V4001 vibro card contains four vibro inputs Input Type IEPE ICP Resolution 24bit Sampling frequency 25 50 100kHz Parallel Processing 1x phase marker The detailed specification is shown in chapter 2 2 4 2 3 2 VM P4230 process values module 2 3 2 1 Description The card contains 4x analog input gt 0 10 mA or 4 20 mA industrial standard gt resolution of 16bit gt sampling frequency of 1kHz gt parallel processing 2x digital input gt 24VDC OC 3x relay output gt contact load 24VDC 100mA NO NC Dodac tutaj karte AR wg schematu jak wyzej str 19 VIBMONITOR USER MANUAL YU 2 3 2 2 Module view LEDs gt PWR indicates the presence of power gt TX module lt gt server transmission gt DO1 to DO3 the status of the digital outputs gt Dl1to DI2 the status of digital inputs ADDR enables setting address depending on the number of the slot where the card has been installed Digital output connectors to control the relays gt DO1 1 to DO3 1 hot wire gt DO1 2 to DO3 2 neutral wire gt relay outputs are characterized by the following parameters 36V Maximum voltage between DOx 1
9. Na ce g e gt ac oc Lu YW WY Figure 2 1 Placement of the connectors on the base plate str 8 VIBMONITOR USER MANUAL YU O O O O O Oo VIBmonitor system can be installed on a mouting panel or on a DIN rail TS 35 Mounting on a panel is reduced to attaching the base plate by screws or bolts to the mounting panel The method of assembling is shown in Btad Nie mo na odnale r d a odwo ania All modules are equipped with convenient separable screw connectors Connection of signals can be done by using wires or cables bare or ended with gas tight cable ends In order to ensure interference immunity only shielded cables should be applied to the transmission of vibration signals Extensive sided contact needs to be Ensured between shield of the cable and the str 9 VIBMONITOR USER MANUAL YU PE potential only near the VIBmonitor unit The base plate must be properly grounded in order to protect the system from the impact of interference Before applying power check for correct connections str 10 VIBMONITOR USER MANUAL EQ 2 2 2 VM PCS100 processing module 2 2 2 1 Description VM PCS100 module is an industrial PC configured to management of VIBmonitor system Allows data acguisition to the internal or external drive connected to the USB port VM PCS100 module also allows remote access to the measurement server VM S101 from anywhere via the Internet VM PCS100 module c
10. a 2A Power supply 24 V DC Power Consumption 45 W Temperature Range 20 60 c Humidity lt 95 RH Operating l l 96x147x23 WIDTH HIGH DEPTH Dimensions IN MM Screws In Set To The Vm Bp6006 Mounting Base Plate 2 3 3 2 Configuration Configuration is done by the manufacturer The user is required to specify the operation type of the module according to the formula as shown below PETEA D O00 CCCC C Channel 4 8 NC Cha NO str 25 VIBMONITOR USER MANUAL EQ VM AR480 module is provided with analog outputs that can be active or passive In the first case channels are powered by VM AR480 card in the second case the power supply must be supplied externally between terminals 24 V and GND of each channel If one configure more than one channel as active outputs GND of individual channels are at the same potential the same is true for the outputs marked 24 V 2 3 4 GSM card This card allows for remote access to the system using GSM technology Module is responsible for sending messages by e mail mobile phone android application The module allows one to send status notifications based on the information on the LCD panel to mobile phone through an application or e mail or text str 26 VIBMONITOR USER MANUAL EQ 2 4 Extensions of VIBmonitor system peripheral devices This the following section provides the information about possible peripheral extensions of VIBmonitor system
11. a ane 16 22A HOW to connect EPE SCMSOlG iis cccccteseeciteeccrins iecactexacsteietapnainsescreccapececstecesamecenecoeanecs 16 2 246 Phase marker iNpUt eenaeccnnreiinsa e 17 22A TECC aN VE ER Em im 18 VIBMONITOR USER MANUAL EQ 2 2 9 VIBmonitor manager software ssssessssssssesessrrressrerssrrrrssreresssreresreresererssreresserereseerese 18 2 3 Extensions of VIBmonitor system functional CALS sessssssssesesrereserrrresrreresrrresrrreresrrressee 19 2 3 1 VO EJ O AN a ee E E E oa en 19 23d VM P4230 process values MOAU OV sova aaa an ea a ja da ea ae 19 die DESNO OM a A E a oo a T 19 po AE a VE RE MM IE ME 20 yi ie o a no eee A RE RE RANE EMA ee 21 DD EO NND oe A eee es 21 DS Data A ene ee elo E EOE a a oe ae ae 22 2320 DENA OUT ONE a E E E a a E 23 2 3 2 7 NA o ea o AVIAN AE VE SE a V NE EEA MNE 24 2 3 3 VM AR480 SA ND OC ANG oa ajo oa ie orjaka anka ae ena 25 Lool MENINI ANN e a E pa oe le aa nin 25 DAS LOPO ON ea eee ati NB ON NA ee ere 25 2 3 4 SI o rrr A aa A Ee a EE ERM MM 26 2 4 Extensions of VIBmonitor system peripheral devices ee 27 2 4 1 TE I LEE LCD p SG a a a EE ek Ee a aaa kah be ka 27 24 1 1 WC TC A ee a nea 27 2 4 2 VIB B eaea E EE E E E E E 27 2 4 3 VIB air SS O A EN E A ME TE MR NEM 27 2 5 Powernne 1e ye sete ee ce acess cee A aaa 28 2 6 Mounting of the VIBMONIROlSY SUG vcccscaecncessmosesscicceccaensuedismortsevievecseucuenelasmoteeeteaenestanseleact 28 2 7 Use and Operator ere
12. input These inputs are designed to work with voltage in the range of 0 24 V DC Examples of connection of proximity sensors with NPN output and PNP are located respectively in the figures below h Lj oli GHD Ungar O FW Up 15 24V VM Pa4730 U a 17 24V Ula O 12Y NOTE Shorted power supply outputs of phase marker pin 1 and pin 3 or pin 4 and pin 6 may cause permanent damage to the module and the system str 22 VIBMONITOR USER MANUAL YU 2 3 2 6 Digital output Module VM P4230 allows the connection of up to three relays The relay should be attached as shown below AA V VM P4230 Figure 2 17 Example connection of digital outputs str 23 VIBMONITOR USER MANUAL YU 2 3 2 7 Technical data Module type VM P4230 process values module Digital inputs Digital outputs Humidity lt 95 RH Operating Dimensions 96x147x23 WIDTH HIGH DEPTH IN MM Mounting Screws in set to the vm bp6006 base plate str 24 VIBMONITOR USER MANUAL EQ 2 3 3 VM AR480 ANDout card A card containing 4x4 20 mA output 8x elay output gt contact load 24VDC 100mA NO NC 2 3 3 1 Technical data Type Of Module VM AR480 ANDout Card No Of Analog Channels 4 Type Of Analog Channels 4 20ma Analog Outputs Sampling Frequency 1000 Hz Resolution 16 Bit No Of Digital Channels 8 Digital Outputs Maximum Working Voltage 30 V DC Maximum Load Current 100 M
13. les 1 6 Electrostatic discharge NOTE VIBmonitor system s components are equipped with electronic components that may be damaged by electrostatic discharge in particular by the connector While performing any tasks such as handling mounting packaging etc use the ESD protection str 6 VIBMONITOR USER MANUAL EQ 2 ViBmonitor system The following section presents basic information about the purpose of the VIBmonitor system The basic version of the system Entry Level EL is described in details Chapter II 3 presents VIBmonitor system s optional extensions 2 1 Purpose of the system VIBmonitor is a modular multi channel and stand alone system running with the machine System through conditioning acquisition of high quality signals and process parameters and their continuous analysis monitors and protects the condition of machines With the verification of real time data automatic detection of a machine s state and an advanced diagnostic analysis system successfully detects anomalies in the early stage of development and significantly reduces the number of false alarms Extension of the system is possible by adding or replacing hardware functional cards VIBmonitor EL is a base version of the system which includes processing card server card and vibro card 2 2 VIBmonitor EL s structure The VIBmonitor EL basic version is composed of the following parts Base Plate VM BP6006 Processing card
14. o use a separate power supply only for the VIBmonitor system In particular avoid common circuit with power contactors and relays Use a miniature circuit breaker 2A characteristic C 2 6 Mounting of the VIBmonitor system The choice of a system s installation place is important Avoid direct neighborhood of devices generating electromagnetic interference in particular inverters commutator motors contactors and relays as well as power cables of medium and high voltage Prior to installation check the system for signs of damage and whether it is complete System after installation looks like in the figure below 2 Use and operation A properly configured and connected system is designed for continuous unattended operation We recommend periodic review of the system once a year by an employee of EC Systems str 28 VIBMONITOR USER MANUAL YU z sysTems EC Systems Sp z 0 0 Lublanska 34 31 476 Krakow Phone 48 12 627 77 80 Sales 48 12 627 77 23 Fax 48 12 627 77 11 e mail info ec systems pl str 29
15. onsists of two Ethernet sockets and two USB ports which may be used to connect a keyboard mouse or external drive 2 2 2 2 Front panel view Individual elements of the front panel of the VM PCS100 module are presented below Power connector gt GND gt PE must be connected to PE gt 24V Power USB ETH Internet connection switch one of the connectors must be connected to the VM S101 server card second connector directly to the host PC LEDs gt ST1 ST8 Status LEDs 2 2 2 3 Configuration Configuration of the server card can be performed by connecting it to a PC via Ethernet The default configuration of the server module VM PCS100 is as follows IP Address 192 168 8 240 Subnet Mask 255 255 255 0 Default Gateway 192 168 8 1 2 2 2 4 Communication To the single PC may be connected multiple VIBmonitor systems The way of correct connection is shown below str 11 VIBMONITOR 192 168 8 254 2 2 2 5 Powering USER MANUAL YU 192 168 8 253 VM PCS100 module requires powering of 24 V DC with at least 12 W power NOTE PE conductor must be connected to the input of the EP 2 2 2 6 Technical data Type of a module VM PCS100 processing module Technical Data Operation Parameters Processor Memory System s drive Data disk External communication interface Internal communication interface Po
16. put 21 Figure 2 15 x Configuration NPN a oa eo ee akne be ane 22 Figure 2 16 Configuration PNP isis nanosi obeske ea kabla ban vibe neb ao ado anka bana ba ika 22 Figure 2 17 Example connection of digital outputs save ee ab ae ere elana 23 Figure 2 18 Method of marking the modules configuration sessesssseessssreresrrressreresrrressrreresrrressne 25 str 4 VIBMONITOR USER MANUAL EQ 1 Introduction In order to ensure prompt and proper installation and commissioning of the system described in this manual user absolutely must to read and comply with the recommendations contained therein 1 1 Copyright This manual including drawings contained in it are protected by copyright law Copying distributing and changing in whole or in part requires written permission EC Systems sp z 0 0 Due to the continuous development of VIBmonitor devices EC Systems sp z o o reserves the right to modify this manual 1 2 Configuration and handling Installation commissioning and operation should be entrusted to a person skilled in matters of electronics industrial automation and measuring technology or specially trained for this purpose The manufacturer is not liable for any damage to the VIBmonitor equipment in part or in whole as well as other related equipment as a result of improper use non use instructions described in this manual or maintenance and operation by unauthorized persons 1
17. s sets cge tierin enneren O EEEE EECA 28 Table of figures Figure 2 1 Placement of the connectors on the base plate 8 Figure 2 2 Placement of the functional cards on the base plate ccccccesecccccesseceeeeseceeeeeeceeeseeseeeees 9 Figure 2 3 A method of mounting on a TS 35 rail a a ea rna a ea ea eo et ai aaa nea 9 Figure 2 4 gt VIBmonitor system ErOUNA snovali vee ode ee ein be geo ke done 10 Figure 2 5 View of the front panel of the VM PCS100 MOdule ccccccsssseceeeeseceeeeeceeeeesseceeaeneess 11 Figure 2 6 Example of network configuration sssseesssseseessrrsssrrresrreessrrrressrerssrereserrresrerreserersseerese 12 VIBMONITOR USER MANUAL EQ Figure 2 7 View of the front panel of the VM S101 MOdUIE ccc eecccccesssecceeeseceecenecceeeaeseeeeaenecss 13 Rysunek 2 8 View of the front panel of the VM V4001 module 15 Figure 2 9 HOW te connect tne TEPE ENSOV unga ae ak kaka ka ba ke a eine 16 Rysunek 2 10 Configuration NPN cccccsseccccsssseccceeseccccescceceessececeeneceeeeesecesseneceeeeeeeeetsnsecesseneeeetsenes 17 Ni o a aa PNP A a a TE ENEM 17 Figure 2 12 The front panel of the V M P4230 module i crcssscinscesscccadanianteanaraxscennhdnedennantiauneunseenandawiants 20 Figure 2 13 Method of marking module configuration ssssssessesreresrrrrsrrereesrrerssreresrrresrreresrrresene 21 Rysunek 2 14 Example of connecting the transmitter to the 4 20mA in
18. sented below Power connector gt GND gt PE must be connected to PE gt 24V power USB used only for the initial configuration ETH Internet connection connect to an external switch directly to a PC or to a processing module VM PCS100 LEDs gt LINK Link Ethernet gt TX Data transmission gt RX receive data str 13 VIBMONITOR USER MANUAL YU gt SPD speed transmission gt ST1 ST4 module status LEDs 2 2 3 3 Powering VM S101 module reguires powering of 24VDC t 1 Server card also enables powering of the extension cards therefore it is important to calculate the total power consumption of the system when the selecting of the power supply 2 2 3 4 Technical data Module type VM S101 server module No of supported modules B Processor 32 MB SDRAM External communication interface Ethernet 10 100 Mb Technical data USB 1 0 Internal communication interface RS485 SPI Mounting Screws in set to the vm bp6006 base plate str 14 VIBMONITOR USER MANUAL YU 2 2 4 VM V4001 vibro card 2 2 4 1 Description VM V4001 module contains 4 input channels enabling conditioning of IEPE type signals the ability to amplify the signal 20 dB phase marker input 2 2 4 2 Module view Individual elements of the front panel of the VM V4001 module are presented below LEDs gt PWR indicates the presence of power gt TX module
19. wer connector System s bus interface Communication connector Power supply Intel Atom Z530 1 6 GHz 512 MB 1 GB DDR2 512 MB 4 GB SSD 2 8 GB SATA II 3 0G Ethernet 10 100 Mb USB 2 0 Ethernet 10 100 Mb SATA II Eurostyle terminal 5 08 mm ZDIN CM 96 RJ45 connector USB A connector 24 VDC str 12 VIBMONITOR Power consumption Temperature range Humidity Protection Dimensions Mounting Mounting 2 2 3 VM S101 server module 2 2 3 1 Description USER MANUAL EN Max 12 W 20 60 C lt 95 RH IP30 96x147x40 WIDTH HIGH DEPTH IN MM Screws in set to the vm bp6006 base plate VM S101 module allows remote access to the VIBmonitor system its modules their configuration and reading the collected data from anywhere using the Internet VM S101 module must be configured via Ethernet before using the system After powering a server is seen by two seconds at 192 168 8 253 at this time one can give it a new network address After assigning of the network address the server is reachable at this address if within 15 seconds it does not receive any command from the PC the default network address will be restored and the cycle will repeat until the server receives a command to execute The module also has an internal power supply to supply other system modules VIBmonitor 2 2 3 2 Front panel view Individual elements of the front panel of the module VM S101 are pre