LMA – LINE MONITOR ALERT USER`S MANUAL
Contents
1. good make sure you test the AUX2 Line Monitoring output of the ADA phone by removing the phone line and wait about 10 minutes until this input will close If this input does not close make sure you have 12 24VDC supplied on the PWR connector of the ADA phone This connector is polarity sensitive If all checks good replace ADA phone and repeat test If the LMA is activated but the phone line on the ADA phone is good disconnect the Alert Input wires from the LMA board to see if that stops the alarm If the Alarm does not stop cycle power on the LMA board or press and hold the Test Reset button onboard for at least 5 seconds to reset the LMA board If the Alarm does stop when the Alert input wires are disconnected then you must check for a short on the wiring or a fault on the AUX2 Line monitor output of the Janus Elevator products ADA phone Notes Figure 1 LMA CONNECTION DIAGRAM Elevator 2 Elevator 1 Janus Elevator Products ADA Phone O Janus Elevator Products ADA Phone O LNI 2 HIMOd Elevator Landing Main Panel O Key Switch Reset Line Monitor Alert Board 2V LED SNI 9NI ZNI UOISUEAXJ JOJIUO 8NI LNd
2. a Janus Elevator Products ADA phone eguipped with a phone line monitoring relay is disconnected or shorted the AUX2 Output of the ADA phone will close within 10 minutes The LMA Board will detect an Alert Input closure and it will trigger the Audible and Visual Alarms The LED s will flash and the Piezo Buzzer will emit a beep every 9 seconds The volume of the Piezo Buzzer is set at optimal Level at the factory but can be adjusted using the VOL potentiometer on the LMA board The Piezo Buzzer can be silenced only by authorized personnel if the Key switch Reset input is closed The LED s will continue to flash until the phone line is re connected or fixed on the ADA phone If an LMX board is used the user can also identify which ADA phone has a phone line issue by checking the LED next to each input If the LED is ON on any of the Inputs it will indicate a phone line failure of an ADA phone connected to this input The LEDs are located inside the LMX enclosure Quick Test To Test the LMA or the LMX Boards you can press and release the Test Reset button On the LMA Board you will see the LED s flashing and you will also you hear the Piezo Buzzer beep at least twice Once every 9 seconds to indicate an active Alert Input On the LMX Board you will see the LED of each input from 1 to 10 light up for 1 second to indicate an Active Input and the Alert Output will then close accordingly If the LMX is conne
3. use and service Avire shall not be responsible for any damage to the unit incurred during installation Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Avire factory service For warranty service contact Avire at 631 864 3699 or 800 527 9156 THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO IS CAUSED BY THE SELLERS OWN NEGLIGENCE OR FAULT Return Policy During installation if a product does not appear to function properly the installer must call the Avire Technical Support Unit at 800 527 9156 Monday through Friday If the technician determines that the product is not functioning an RA Return Authorization number will be issued allowing the installer to return the product directly to Avire for repair replacement or credit Returns with no fault found will result in a bench charge plus shipping costs Returns without an RA number will result in a restocking charge of 25 or more plus shipping costs Need Technical Assistance Call 1 800 527 9156
4. JANUS LMA LINE MONITOR ALERT USER S MANUAL PRONE LINE MONITOR ALERT PANEL S ELEVATOR COMMUNICATION FNLURE Avire Inc 415 Oser Avenue Suite Q Hauppauge New Vork 11788 Phone 631 864 3699 Toll Free 800 527 9156 Fax 631 864 2631 Email sales us avire global com Janus is a brand of Avire TABLE OF CONTENTS SECTION OVERVIEW INSTALLATION OPERATION 8 TEST TROUBLESHOOTING LMA CONNECTION DIAGRAM LMA MOUNTING DIAGRAM LMX MOUNTING DIAGRAM SPECIFICATIONS WARRANTY POLICY RETURN POLICY Overview The Line Monitor Alert Board LMA provides visual and audible alerts when detecting a contact closure at the Alert input The Alert input of the LMA board can be connected to the Phone line monitoring output AUX2 of any Janus Elevator Products ADA phone that includes it This will allow monitoring the status of the phone line on a Janus Elevator phone or any other ADA phone equipped with such output If more then one ADA phone needs to have the phone line monitored then the LMA should be used in conjunction with the Line Monitor Expansion Board LMX which will support up to 10 ADA phones If more then 10 phones are used then you could use multiple Expansion Boards and connect the Alert Output of one Expansion Board to any of the Inputs of another Expansion Board LMX If the ADA phone s are connected to an 55 call director then you should also use the Line Monitor Expansion Board LMX an
5. LNO Jaan ALERT 6 12V LED o INPUT Q oo O OLNI 6NI Figure 2 LMA MOUNTING DIAGRAM PHONE LINE MONITOR o ELEVATOR COMMUNICATION FAILURE 3 250 39 lt e o a o lt F 2 5 o x l 20 250 4 PLCS 20 090 4 PLCS Electrical Operating Voltage 12 24 Operating current 400mA Supplied with standard 12VDC 0 5A transformer Operating Temperature Range 0 to 70 degrees Storage Temperature Range 20 to 70 degrees Relative Humidity Up to 95 non condensing Operating Voltage 12 24 VDC Operating current 150mA Supplied with standard 12VDC 0 5A transformer Operating Temperature Range 0 to 70 degrees Storage Temperature Range 20 to 70 degrees Relative Humidity Up to 95 non condensing Warranty Policy Avire Inc warrants its products to be free from defect in materials and workmanship under normal use and service for 24 months from date of purchase Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any product which proves defective in materials or workmanship under normal
6. cted to the LMA while performing this test you can test both systems at once Note This Test will only Test the functionality of the LMA and LMX boards Please refer to the Complete System Test below to test the entire phone line monitoring system Complete System Test In order to test the entire system you must first make sure everything is connected and powered up according to the Installation Instructions of this manual Remove the phone line from the ADA phone and within 10 minutes the Alert Input of the LMA board will close and this should cause the LED s to flash and the Piezo Buzzer to sound If the LMX is also used it will close the Alert input of the LMA board if any of it s 10 inputs is closed Activate the Key switch Input on the LMA board to make sure you can silence the Piezo Buzzer but make sure that the LED s continue to flash To turn OFF the LED s and the Piezo Buzzer on the LMA board Re connect the phone line to the ADA phone Troubleshooting 1 If the LMA LMX do not turn ON make sure that wall transformer is plugged into 110VAC outlet and measure the voltage on the POWER connector inside the LMA LMX unit The voltage should read about 12 24VDC The POWER connection is not polarity sensitive If the phone line is removed from the ADA phone and it does not trigger an alarm first check the connections according to diagram on Figure 1 If all connections are
7. d connect the AUX1 of the EMS5 to any of the inputs of the LMX board and the ADA phones to the rest of the inputs Installation The LMA require 1 pair of wires from the Phone Line Monitoring output AUX2 of the ADA elevator phone to the LMA Alert input See Figure 1 The LMX require 1 pair of wires from the Phone Line Monitoring output AUX2 of each ADA elevator phone to each input of the LMX and 1 pair of wires from the LMA Alert input to the LMX Alert output See Figure 1 The LMA LMX system requires 12 24VDC 0 5A to operate The Power terminal is not polarity sensitive Note 1 Cabling can be inexpensive 18 24 gauge pair cable Note 2 If the Phone line Monitoring output of the ADA elevator phone is normally close NC instead of the standard normally open NO output you can install a jumper at the location next to the Alert input connector s of the LMA or LMX units OPTIONAL If an LMX unit is provided Install it on the wall or flat surface with 4 8 32 screws using the 4 holes on the sides of the unit See Figure 3 Operation 8 Test 1 The LMA and LMX boards are both equipped with Power Board status LED When the Board is first powered up the LED will flash rapidly to indicate Resetting and then flash slower to indicate normal operation If you need to reset boards without removing power you can press and hold the Test Reset button for at least 5 seconds If the phone line from