Home

Section 10 - AutomationDirect

image

Contents

1. 600 Current and TCA601 Timer Counter 601 Current With the combination of the inclusive status register R16 and the designated internal relays C161 C162 and C163 in the Data View window you can now write to any of these bits via the status register or read them directly by observing their respective bit values 0 or 1 Additionally you can watch TCA600 and TCA601 to see their respective values incrementing as the program runs Element Status RC160 0000000 Start Switch OFF Test Output a Test Output TCA6O00 TCA601 Data View Instructions for the DL305 Changing to the You are now ready to test the program First place the PLC in the RUN mode Select Run Mode the traffic light icon of the on line tool bar Then click on the Run mode You could also have chosen PLC from the main menu bar selecting PLC Modes from the list of choices and then selected Run mode from the pop up dialog box es i oo E Enz sn PEAN Click on the traffic light icon to enter Run mode Enabling the To monitor the status of each element you will need to place the software in the All All Status ON Status ON Mode Click on then All Status ON File Et Search View Tools PLE pablus Window Help hel ese Status Grashates bl i Lil fl AB Status 0n mir AB Status Off Data View A nE Dhange Vahm Cirih Shitt4F Entering Data for Start the program by writing a 1 to the status of the first
2. bit in R16 which is actually the Status Register C160 Do this in the Edit column of the Data View window Sometimes the Data View window is not fully expanded To make the Edit column visible place your cursor on the vertical line that defines the right side of the status label Hold down the mouse button and drag it to the right Once the Edit column is visible type in the 8 binary digits with the right most digit least significant digit as a 1 This is 00000001 a ae T EER TTL ie rrr A l Fie Ei earch ai tes RSM Berar he Stretch at this vertical In the Edit column enter the line if the Edit column is binary number that will set the not showing first digit representing the status of C160 to 1 Writing the Edits to the PLC Click on Yes to confirm Timer and counter increments Start Switch is ON Data View Instructions for the DL305 To write the new status to the PLC select the icon with the single arrow pointing down to the PLC from the on line tool bar The other icon showing several arrows is for ene mae edits to the PLC PLC Debug Windes Hep Click here to write your Edit After selecting the appropriate Write Edit to PLC icon you will then see a confirmation dialog It will ask if you want to write the edit or edits to the PLC You answer yes With the Start Switch C160 now ON you will see the active elements change color as the counter accumulates each tick of the timer
3. Data View Instructions for the DL305 aT Special Data View Instructions for DL305 Family DirectNET Restrictions Unlike the DL105 DL205 and DL405 PLC families the DL305 family can only use DirectNET protocol This protocol allows you to READ the status of each internal relay directly but it will not allow you to use the Data View window to change the status of an internal relay by WRITING to that bit individually Instead you must do so indirectly by addressing the respective status register that includes the bit whose status you wish to change Using the example introduced on Page 6 of this manual C 160 was designated as the Start Switch If you refer to the memory map for the DL3805 you would find that C160 is the first bit of status register R16 Consequently in order to change the status of the Start Switch via the Data View window you must write an 8 bit word to R16 making sure the first bit is flagged You can start by first entering the element R16 in the Data View window When moving the cursor to click another field you will notice the alias RC160 appears in place of R16 Do not confuse this alias with C160 The RC designation refers to the entire 8 bit register R16 but C160 refers only to the first bit The number shown in the status column by default is in BCD hex format Ete Eat Beon wiee Tails ELG Dateg Barwin iep ror ae grit in 7 R nET CE Gai Ari E Yew ou E ee aut ir 7 z ae i alr jE H I When you mo
4. and the Boolean conditions are met Now you can observe how the program runs Be sure to read the main user manual later _biaectiart Prap manan PAPE 1 EH Seeth Mew fess FIC aa ch Pan Se COO M t E l
5. ve the cursor to another field R16 is replaced by the alias RC160 48 Data View Instructions for the DL305 Changing the Value The BCD hex format does not allow to easily see the status for each of the 8 bits in to Binary to Observe All 8 Bits R16 RC160 Therefore you will need to change the format to binary The Data View window has a drop down button that can be used to select the binary format This button is above the Element column Select the button and you will see the several choices of formats available Select Binary from the list Notice now the value shown changes to 0000000000000000 indicating a binary number format However it shows a default of 16 bits Since the status registers are each 8 bits in size click on the drop down button above the Status column and change from WORD size to BYTE size data This then displays only eight zeros 00000000 Click here to change from WORD to BYTE status Click here to change to binary format Although you could use R16 to view the status of C160 Start Switch C161 Output1 and C162 Output2 it is more convenient to view the internal relays directly for read only purposes Now you can type in the contacts by name C160 C161 and C162 The software will substitute the nicknames for you These use the bit format to show the contacts as being turned ON or OFF If you see a 1 the bit is ON If you see a 0 the bit is OFF Include also TCA600 Timer Counter

Download Pdf Manuals

image

Related Search

Related Contents

P`9982 Smartphone-Manuale utente  1769-UM004 - Rockwell Automation  Les Instructions D`Utilisation Nettoyeur À Tapis Triple  RHF18/450ERT RHF22/620ERT  Polar Cardio GX: Temas de Ayuda Manual del Usuario  OP01068_取扱説明書(PDF 141KB)  MMI ポータブル低圧持続吸引器 取扱説明書  User Manual - DataDisplay Group  Alliance Laundry Systems 907003062 Clothes Dryer User Manual  MANUAL VTR804.indd  

Copyright © All rights reserved.
Failed to retrieve file