1. Degree of protection Data interfaces Interface Type of connection DIAG from version 1 0x CMD from Version 4 0x CMD from Version 4 0x DIAG from version 1 0x Via SIMATIC I O bus 1 5A 5 V DC 4 8 V DC 5 3 V DC including ripple 2 2 MVpp 500 g 2 narrow slots IP00 INTERBUS remote bus 9 pos D SUB female connector optionally optical fiber possible via interface converters with electrical isolation PHOENIX CONTACT Inc USA http www phoenixcon com Page 2 6 Oct 22 2009 IBS S5 DSC I T Order No 2752000 http eshop phoenixcontact de phoenix treeViewClick do UID 2752000 Interface Type of connection Interface Type of connection Interrupts INTERBUS data Type Number of devices with parameter channel PCP Number of supported devices Certificates Approvals cAi us EG Certification CUL Nominal voltage Un Nominal current ly UL Nominal voltage Uy Nominal current ly Accessories Item Designation Cable conductor 2806862 IBS PRG CAB 2762003 PSM KA V24 TTY P PA BB Memory 2729389 IBS MC FLASH 2MB Parameterization operation diagnostics RS 232 C D SUB 9 pos male connector Host system Siemens SIMATIC S5 115U requires adapter capsule 6E5S 491 OLB11 155U 130 WB 150S Are supported INTERBUS master max 62 max 512 of which 254 are remote bus devices bus segments CUL GOST UL 5V 1 5A 5V 1 5A Description Connection cable to conne
2. the FB60 ISFPINI ADDR KF xxx corresponds with the preset value of the DIP switches on the controller board If you have programmed a DBO or DB1 depends on controller type check that the address of the communication register has not been used there See also INTERBUS User manual driver software for controller board for Siemens SIMATIC S5 Order no 27 47 73 0 Designation IBS 55 DSC SWD UM INTERBUS Quickstart Order no 27 47 66 2 Designation IBS 55 DSC QS UM e How can I use the extended I O area Q for the SIMATIC 115U and the IBS S5 DSC controller board The expanded I O area Q can be used for PLCs with CPU type 945 if the controller board is in a PLC expansion rack The bus in the base rack of the PLC does not allow simultaneous use of the P and Q areas The expanded I O area Q cannot be used for 115U PLC series with other types of CPU e How do I set the data consistency The data consistency depends on the setting in the CMD software tool and on the operand in STEP 5 16 bit consistency L PW T PW 32 Bit consistency L PEW T PAW The following marginal conditions must be observed A consistency range assigns sequential addresses which must be addressed one after another Access the ranges in the preset consistency e g 8 bit consistency byte commands Data transfer must not be interrupted by alarm management or interrupts Data consistency gt 32 bits is typically possible but is not guaranteed Synchronous operating mode ca
3. FB60 ISFPINI in the PLC to start the INTERBUS interface The ISFPINI function block synchronizes the PLC with the controller board The idea is to keep the PLC in the starting mode until the controller board indicates that it is ready for operation See also INTERBUS User manual driver software for controller board for Siemens SIMATIC S5 Order no 27 47 73 0 Designation IBS 55 DSC SWD UM PHOENIX CONTACT Inc USA Page 5 6 http Awww phoenixcon com Oct 22 2009 IBS S5 DSC I T Order No 2752000 http eshop phoenixcontact de phoenix treeViewClick do UID 2752000 Address PHOENIX CONTACT Inc USA PHCENIX 586 Fulling Mill Road CONTACT Middletown PA 17057 USA Phone 800 888 7388 Fax 717 944 1625 http www phoenixcon com 2009 Phoenix Contact Technical modifications reserved PHOENIX CONTACT Inc USA Page 6 6 http Awww phoenixcon com Oct 22 2009
4. PH NIX CONTACT Extract from the online catalog IBS 55 DSC I T Discontinued item Order No 2752000 http eshop phoenixcontact de phoenix treeViewClick do UID 2752000 Termination Boards for Siemens SIMATIC S5 PLCs with electrical isolation http www download phoenixcontact com Commercial data Please note that the data given here has been taken from the EAN 4017918120269 online catalog For comprehensive Pack 1 information and data please refer zis pes to the user documentation The Customs tariff 85389091 General Terms and Conditions of Use apply to Internet downloads Weight Piece 0 5427 KG Ay PHOENIX CONTACT Inc USA Page 1 6 http www phoenixcon com Oct 22 2009 IBS S5 DSC I T Order No 2752000 http eshop phoenixcontact de phoenix treeViewClick do UID 2752000 Product description INTERBUS controller boards for Siemens SIMATIC 55 controllersSIMATIC S5 115U through to 155U PLCs can be connected to INTERBUS by means of the IBS S5 DSC I T controller board The controller board is connected to the controller via the SIMATIC I O bus It functions as a system I O module with a variable address area so that the data of the INTERBUS input and output modules can be accessed directly using the periphery L PW T PW or indirectly using the process image AI S Q The INTERBUS system is activated automatically at power on or through the application For this option a system specific parameter ass
5. ct the controller boards to the PC RS 232 C length 3 m Connection cable to connect the controller board to the Pg TTY length 90 cm Program and configuration memory 2 Mbyte PHOENIX CONTACT Inc USA http Awww phoenixcon com Page 3 6 Oct 22 2009 IBS S5 DSC I T Order No 2752000 http eshop phoenixcontact de phoenix treeViewClick do UID 2752000 Software 2730307 DIAG Diag diagnostics software for INTERBUS networks area of application Startup maintenance and for example for integration in control desk software can be integrated in 32 bit applications ActiveX capable 2721439 IBS CMD SWT G4 Network configuration software for INTERBUS Generation 4 2721442 IBS CMD SWT G4 E Network configuration software for INTERBUS Generation 4 FAQs e Additional parameter Data Consistency when using the IB DB data block During parameterization of an IBS 55 DSC I T controller board with the IB DB data block a value must be entered for data consistency in addition to the parameters described in the manual If this value is not entered the following message is displayed lt OA44hex module address gt Example data consistency for eight bit Entry KY 128 070 The entry 128 indicates that bit 15 is set and therefore that a data consistency of eight bits is ensured e Control system switches to STOP state with an acknowledgment delay when executing FB60 IFSPINI Check whether the communication register as a parameter on
6. ignment for the INTERBUS system and controller board is stored centrally in a pluggable parameterization memory on the controller board The user friendly IBS CMD SWT INTERBUS software for the Windows operating system is available for creating the parameter data In addition to parameterization configuration and system documentation IBS CMD SWT as universal software also makes possible the diagnostics of individual devices and the entire INTERBUS system Furthermore the local status of the connected INTERBUS devices can be displayed while the system is in operation The following range of functions supplements this high performance controller board Process data preprocessing to IEC 1131 Synchronous operating modes Parameterization of alternative and changing bus segments Parameterization using CMD Startup using Plug amp Play technologyThe IBS S5 DSC controller board offers a user oriented LC display for visualizing the extensive INTERBUS system diagnostic capabilities Operational and error states are shown on this display in plain text format The direct display of messages helps reduce startup and downtimes increasing the reliability of your systems Technical data Control system Diagnostics tool Configuration tool Software requirements Configuration tool Diagnostics tool Power supply Connection supply Typical current consumption Supply voltage Range of supply voltages Residual ripple General data Weight Format
7. n be helpful here e Is it possible to implement a bus parameterization with isolated disconnection if an incorrect bus is connected Yes it is possible Before a bus start it however is necessary to activate the configuration frame Activate configuration frame Code 0711 Parameter_Count 0001 Frame_Reference 0001 Start bus Code 0701 e Message 0946hex in the display of the controller board after writing the parameterization memory The write protection of the parameterization memory is activated Deactivate the write protection of the flash EPROM of the controller board parameterization memory See also INTERBUS User manual Services and error messages of the firmware order no 27 45 13 0 Designation IBS SYS FW G4 UM INTERBUS Diagnostics guide G4 Order no 27 47 28 0 Designation IBS SYS DIAG DSC UM PHOENIX CONTACT Inc USA Page 4 6 http Awww phoenixcon com Oct 22 2009 IBS S5 DSC I T Order No 2752000 http eshop phoenixcontact de phoenix treeViewClick do UID 2752000 e Message 09D1hex on the controller board display controller board not in RUN state The flash EPROM in the controller board was recognized as being faulty Replace the flash EPROM with a new one and start the controller board as usual See also INTERBUS User manual Services and error messages of the firmware order no 27 45 13 0 Designation IBS SYS FW G4 UM INTERBUS Diagnostics guide G4 Order no 27 47 28 0 Designation IBS SYS DIAG DSC UM e New MC fla
8. sh memory cards From firmware 4 35 there are 2 MB and 4 MB memory cards for all G4 controllers with PCMCIA slot 27 29 38 9 IBS MC FLASH 2 MB 27 29 39 2 IBS MC FLASH 4 MB e The PLC does not start when using the IBS 55 DSC controller board in a SIMATIC Another device in the PLC multiprocessor coordinator intelligent modules PCs has assigned I O addresses in the preset communication register PW252 on the IBS S5 DSC controller board This means that addresses are assigned twice Change the address of the communication register on the controller board as well as on the starting module ISFPINI FB60 If you have configured the bus using the CMD software from Phoenix Contact you must also enter the new address for the communication register Please make sure that all other registers diagnostic register control register are modified correspondingly IMPORTANT The changed communication register should lie outside the process image PW0 PW127 otherwise services which are issued to the controller board using a function block may not be executed or may be executed incorrectly e The services which were issued from the PLC to the controller board using a function block are not executed or executed incorrectly A possible cause is that the selected address for the communication register is in the area of the process image Please make sure that the communication register is outside the process image from PW128 e Why do I need a function block