1. Explanations for Control Panel and Potentiometer After power on LCD display displays the company s LOGO PR After reset the display is at initial display status showing information about company s name including LOGO PR fixture s model and DMX address if the start address is 001 it displays as address 001 and at the same time the display is locked To browse through or change a fixture s configuration after ENTER button has been pressed for about 3 seconds the display of AddR means the entrance of the menu To set or browse through a fixture s settings press buttons of Up and DOWN After button ENTER is pressed a sub menu is entered showing current parameters while parameters flashing Press button Up or DOWN to change values plus or minus Press button ENTER to save your settings or enter into the upper level menu and the parameters stops from flashing Press FUNG to enter into the upper level menu parameters not saved or browse through the upper level menu After FUNC is pressed for more than 1second or buttons not pressed for more than 1 minute it will go back to LCD display initial stage After the exit of the menus the fixture s brightness can be adjusted by potentiometer Only after the exit of the menus and no DMX signal can this work If there is DMX signal the DMX signal indication will be on and at
2. LED Studio 3203D 3203T PR 3203T PR 3203D This product manual contains important information about the safe installation and use of this unit Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR LIGHTING LTD http www pr lighting com jason sce 2 SAFE USAGE OFTHE UNT EEEE ENE E 3 D ER CRILISUL T 4 CONTROL CONNECTION 4 DMX TERMINATOR S M 5 OPERATION MENU con HR EH AER AR EC RE aa A A Ae sil 6 DMCPROTOCOL cn s k pik p k aka k s ki s n f a s ke k ki s n f a p kn p ki pi n an p kn pk pi n f an k shal pf a n A a n A A RE DER 6 INDICATION OF LED DIGITAL TUBE n a on n on n a on l n on c e n Ce Ce ce ce ce po cec e etd 6 SETUP OPTIONS UNIT CONFIGURATION eeeeeeee tenente nennen tenete tenete tenete tenete tenete tenete tenete tenente tenens 7 MAINTENANCE 5 eere ei RE QU UH Gi DU UNDO n Da da enki Re Dean EH quei qu qp 8 TROUBLESHOO PING fesse antes ck heli ae oS Oe Dodo Rege a OOo USO Lotte 8 TECHNICAL DATA eke a seke RR RUE ND RN ER aai e 9 ELECTRICAL DIAGRAM 42 stu ctnd hoa died ect da cde AEA tae aa ddd eb Maa AIA HORA NE Raa AS 11 COMPONENT ORDER CODES 2 9 9099999 9 9 9 0 9o n dostoqellatiageqetogagedetegegaqegoqgupeqodqe 11 BACK COVER ote eese
3. CONTROL CONNECTION DMX OUT DMX IN DMX 512 5 PIN o FUND ON i o o ie s Bar 4 2 d pe 2 NE 3 3 4 12 Connection between the controller and a unit and between one unit and another must be made with a 2 core screened cable with each core having at least a 0 5mm diameter Please use the unit s cannon 5 pin signal input and output cables as connection The 5 pin signal connections are connected as shown in the figure above Note Care should be taken to ensure that none of the pins touch the metallic body of the plug or each other The body of the plug is not connected in any way The unit accepts digital control signals in protocol DMX512 1990 The maximum of units in parallel for operation is 16 pcs Connect the controller s output to the first fixture s input and connect the first fixture s output to the second fixture s input and connect the rest fixtures in the same way Eventually connect the last fixture s output to a DMX terminator as shown in the figure below Note for synchronous control the start addresses of all slaves should be same Each unit should be connected to power supply individually and the voltage and frequency of the power supply should match those indicated on nameplate DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX Terminator DMX TERMINATOR In the Controller mode at the last fixture in the chain the DMX output has to be connected with a DMX terminator This
4. do not open the housing and never operate the unit with the covers removed Ifany questions don t hesitate to consult your dealer or manufacturer Always disconnection from the power when the device is not in use or before cleaning or any maintenance work 3 12 INSTALL THE UNIT Safety cord for fixture s body Mounting structure for a safety cord The figures above with a Mounting Bar for the illustrations of the installation is for our clients reference and it is not a accessory to be supplied up on delivery This fixture should be hung upon use but not hung by its side The whole fixture can be rotated by hand within the range of 180 degrees While installation take out two safety cords supplied and hook the clamp to the fixture s support then hook the clamp to the Mounting Bar and tighten the fasteners of the clamp to mount the whole fixture Please be sure that the fixture is mounted securely and the mounting place strong enough to support the fixture s weight For safety please run a 1 2m safety cord supplied through the Mounting Bar and the Mounting Structure of the fixture and a second 0 55m safety cord though the barn door module as the figures above for the supplement to ensure safety Warning 1 The unit MUST be lifted or carried via supporting frame instead of clamps 2 For safety the long safety cord should afford 10 times the unit s weight and the short one 10 times barn door module s weight
5. tenes ate tenete Sera ei a ears dia ek aee trees ea East e eR Ee ke eR ek apa thae 12 Please note that as part of our ongoing commitment to continuous product development specifications are subject to change without notice Whilst every care is taken in the preparation of this manual we reserve the right to change specifications in the course of product improvement The publishers cannot be held responsible for the accuracy of the information herein or any consequence arising from them Every unit is tested completely and packed properly by the manufacturer Please make sure the packing and or the unit are in good condition before installation and use Should there be any damage caused by transportation consult your dealer and do not use the unit Any damage caused by improper use will not be assumed by the manufacturer and or dealer ACCESSORIES These items are packed together with the unit Name Quantity Unit Remark Safety cord 2 Pc With one 1 2m and the other 0 55m in length XLR signal cable 1 Pc Power cord 1 Pc Users manual 1 Pc Clamp and Mounting Bolt 1 Set 2 12 SAFE USAGE OF THE UNIT When unpacking and before disposing of the carton check there is no transportation damage before using the unit Should there be any damage caused by transportation consult your dealer and do not use the apparatus The unit can be only used indoors IP20 The fixture should be kept in dry place without exces
6. 203T 3200 250 PR 3203D 5600 250 Luminous Flux PR 3203D 14 7100 Im 48 10700 Im PR 3203T 14 5300 Im 48 8300 Im CRI Ra gt 93 DIMMER 0 100 linearly adjustable Zooming Motorized Zooming is available BEAM ANGLE Field angle 1 10 peak 6 14 48 CONTROL DMX3512 5 pin interfaces HOUSING High intensity aluminum alloy IP20 WORK ENVIRONMENT TEMPERATURE 20 C 40 C NET WEIGHT 16KG 9 12 SIZES 670x355x520mm Light Output Luminous Flux 48 lux 1223 363 183 106 70 50 14 lux 10470 2614 1221 704 466 336 7m 6m 5m 4m 3m 2m om 1m 1m 2m 3m 4m 5m Projection distancdm Om 5m 10m 15m 20m 25m 30m 6m 7m 14 Diameter m 0 0 1 21 2 43 3 64 4 86 6 07 7 29 48 Diameter m 0 0 4 18 8 36 12 53 d16 71 620 89 25 07 10 12 ELECTRICAL DIAGRAM LLU NLGND VCC Swithing power supply 320W COMPONENT ORDER CODES NAME PARTNO QUANTITY REMARK SIGNAL CABLE 230090003 1 5m POWER SWITCH 192010182 1 HLG 320H 48 DRIVER BOARD 230060288 1 DIGITAL DISPLAY BOARD 230060290 1 LED LIGHT SOURCES 150020278 1 CT 5600K LED LIGHT SOURCES 150020277 1 CT 3200K 11 12 PR LIGHTING LTD PR New Hi tech Science Park 1582 Xingye Avenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 FAX 86 20 3995 2330 P N 320020223 Version 20140804 12 12
7. for a long time damp smoke or particularly dirty surroundings can cause greater accumulation of dirt on its cover and housing So it should be cleaned to maintain an optimum light output and at the same time to prevent it from being corrupted by acid gas Cleaning frequency depends on the environment in which the fixture operates Soft cloth and typical glass cleaning products should be used for cleaning It is recommended to clean unit at least once every 20 days Do not use any organic solvent e g alcohol to clean housing of the apparatus TROUBLESHOOTING PROBLEM ACTION gt Power connection is not correct gt Power supply is damaged or abnormal Call a qualified personnel to fix The unit doesn t switch on it gt Connection of control board is not correct Call a qualified personnel to fix it The unit can be turned on but LEDs do Connection of LED board is not correct Call a qualified personnel to fix not emit light and are out of control it The lamp comes on but the unit doesn t gt Make swe that the unit is correctly configurated respond to the controller gt Replace or repair the DMX cable The beam appears dim gt The unit is too hot Take ventilation measures to make it cool 8 12 TECHNICAL DATA VOLTAGES 100V 240V AC 50 60Hz POWER CONSUMPTION 280W 220V LED Power consumption 250W Quantity Ipc Manufacturers Rated LED Life 50000 Hours COLOUR TEMPERATURE PR 3
8. he display is locked initial stage of the display press the ENTER for more than 3 seconds to unlock it then press UB or DOWN to find the menu of Information and press ENTER to enter sub menus Press UB or DOWN to find secondary submenus of LED Temperature Fixture Time and Software Version Press ENTER if the information is desired 4 Manual Dimming At the initial stage of the display after the exit of menu and without DMX signal 0 100 linear dimming is available by potentiometer Knob 5 Reset Test Automatic reset will be done after first Power on or re Power on after a Power off While reset the control panel will display big PR Logo After reset the control panel will display some information about logo product model a fixture s DMX address and etc and fixture s angle be adjusted to the one before last power off During the reset there may be some strange sounds like Du Du for about 20 seconds but this is a normal phenomenon Dimmer Priority Sequence Priority Sequence Digital Operation Panel DMX Dimmer Potentiometer Dimmer 1 Under Menu Mode Potentiometer Dimmer doesn t work 2 Under Menu Mode DMX works normally excluding Dimmer Function 3 Ifthe menu is under Dimmer Mode DMX Dimmer amp Potentiometer Dimmer don t work MAINTENANCE To prolong the life of the unit it is very important to do the maintenance work If the unit is idle
9. prevents electrical noise from disturbing and corrupting the DMX control signals The DMX terminator is simply an XLR connector with a 1200 ohm resistor connected across pins 2 and 3 which is then plugged into the output socket on the last unit in the chain The connections are illustrated below DMX TERMINATOR CONNECTION Connecta 120 OHM resistor across pins 2 and 3 in an XLR plug and insert into the DMX out socket on the last unit in the chain PIN2 ping 5 12 1 level menu 2 level menu 3 level menu Remarks DMX Address 001 512 Setup of DMX Address Config Setup LED Dimmer Test Reference Only not saved Focus Position Linearly focusing Lcd Light Setup On ON Off Display shuts off 3 minutes after buttons are not pressed after the exit of menus Language Setup English Language selection Chinese Display Inversion On Display Inversion Off Information LED Temperature XXXX Fixture use Time VXX Fixture usage time Software Version VXX DMX PROTOCOL CHANNEL FUNCTION DMX DESCRIPTION 1 Dimmer 000 255 From dark to bright 000 007 NO strobe 2 Strobe 008 255 Strobe speed from slow to fast 3 Focusing 000 255 From small angle to big angle INDICATION OF LED DIGITAL TUBE ON DMX signal OFF NO DMX signal ADD Indication 6 12 SETUP OPTIONS UNIT CONFIGURATION DMX O Jav D FUNC DOWN ENTER iier
10. sive dampness heat dust and contact with water or other liquids The unit is not designed or intended to be mounted directly on to inflammable surfaces X The unit is only intended for installation operation and maintenance by qualified personnel Do not project the beam onto inflammable surfaces minimum distance is 2m 9 2m Avoid direct exposure to the light from the lamp The light is harmful to eyes Do not attempt to dismantle and or modify the unit in any way Electrical connection must only be carried out by qualified personnel Before installation ensure that the voltage and frequency of power supply match the power requirements of the unit It is essential that each unit is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cord come into contact with other cables Only handle the power cord by the plug Never pull out the plug by tugging the power cord When the unit is hanged to a high place please use a safety cord provided to pass through the unit s support as a secondary safety fixing for safety seasons For details refer to INSTALL THE UNIT section Exterior surface temperatures of the unit after 5 minutes operation is 45 C when achieving steady state it is 55 C There is no user serviceable parts inside the unit
11. the same time LCD display displays DMX address accordingly otherwise the indication will be off After the startup of the fixture reset begins but the lamp will be on after the reset is completed at this stage the brightness of the fixture is as what the potentiometer points to If the brightness needs to be changed please follow the above mentioned instructions After reset the focal length will be the one set during last use Operation Guide l Setupof Start Address Each unit must be given a DMX start address so that the correct unit responds to the correct control signals This DMX start address is the channel number from which the unit starts to listen to the digital control information being sent out from the controller The unit has 3 DMX channel so set the No 1 unit s address 001 No 2 unit s address 004 No 3 unit s address 007 and so on 2 Configuration Setup While the display is locked initial stage of the display press the for more than 3 seconds to unlock it then press Up or DOWN to find the menu of Config Setup and press ENTER to enter sub menus Press UB or DOWN to find secondary submenus of Dimming Focusing LCD display Language and Display Inversion Press if the submenu is 7 12 desired then change the parameters after pressing Up or DOWN At last press ENTER to save it and go back to the upper level menu 3 Information While t

Download Pdf Manuals

image

Related Search

Related Contents

MANUAL DE INSTRUCCIONES TIRAS LED - Led  User Guide - Logo Mon Electrostimulateur  Aide juridictionnelle  diseño y construcción de un sistema electrónico basado en tarjetas  OPERATOR`S MANUAL  informativo de licitações e contratos tribubal de contas da união    GL6(G)  Tiger Products Co., Ltd NH TS100  Computer Gear 26-0802 firewire cable  