Home
        Photonic Satellite
         Contents
1.             Speed and temperature increase MP     Therapeutic options   With your Satellite you can select and irradiate geometric forms in order to treat the body  in correct dimension fitting to the body part Additionally you can determine the speed of  the movement of the beams     By means of this innovative options you may apply more therapeutic effect  If you want a   more point orientated therapy  slow down the speed this will bring more heat to the body   in case you want less heat  simply reduce the speed  The supplied energy remains the  same     Temperatur   an einem Punkt        Temperature at low speed  More heat because the laser remains a longer time on a point     Temperatur   an einem Punkt          Temperature bat high speed  Less heat because the laser moves faster from point to point     point          Care and maintenance    Cleaning and disinfection   Unplug the power cord of the Satellite unit before beginning all cleaning and care    Please ensure that you do not use sharp or caustic agents  e g  acetone  when cleaning the  plastic parts  Avoid getting moisture in the housing A damp cloth is the best cleaning tool     To disinfect the device  use a soft cloth that has been dampened with a mild DGHM appro   ved  DGHM Deutsche Gesellschaft fur Hygiene und Mikrobiologie German Hygiene and  Microbiology Association  disinfecting agent     Always use a damp cloth for cleaning and disinfection     never flush water over the    device  Do not use a solvent   
2.   If you work with an applicator  sterilise the applicator after each use in order to avoid  transmitting infection to the patient        Calibration and safety check  Your Satellite does not contain internal parts or components that need to be serviced by  the user  Thus  there is no reason to open the device housing     In order to comply with the regulation EN 60825 1    Safety in laser facilities     your Physiola   ser Olympic unit  along with all probes and accessories  should be sent to the manufacturer  for checking and recalibration no longer than one year after you begin to use it     Please be aware that the annual safety check is mandatory and is legislatively prescri   bed by the Medical Devices Act  in Germany  MPBetreibV   6   Please contact your    retailer             Technical description    Technical Data    Weight 4kg       Transport and storage       Relative humidity 30  bis 75        Laser Diodes       Ix red 638 nm max  150 mW Continuons  gt 10m 3 mrad    beam  CW        LED Diodes         Safety margin  NOHD  The distance at which the radiation strength or the radiation is equal to the corresponding limit for the maximum permissible    radiation of the cornea  MPE Maximum Permissible Exposure      11         Guarantee and disposal    Guarantee   The manufacturer   s guarantee is valid for 24 months  The manufacturer is only responsible  for the features warranted by the user manual  if the device has been operated carefully  according to the user manu
3. Photonic Satellite    Compact scanning device    Operation manual          LASER    Introduction       Your Physiolaser with the Photonic Satellite  Two in one    Thank you for choosing the Physiolaser including the Photonic Satellite     the latest generati   on  high quality laser device from Reimers  amp  Janssen GmbH     The RJ laser design is founded on over 28 years of experience in the development and pro   duction of laser devices for medical therapy  Our profound knowledge about complemen   tary therapy methods are built into this product  gentle laser therapy for a broad scope of  applications     The Physiolaser involves a base device with a microprocessor  which can control all laser  probes available from Reimers  amp  Janssen GmbH  Thus  the Physiolaser is the basis of our  trend setting concept  universal versatility with ease of operation     Whether you are using surface probes  single probes or laser needles  with the efficient Phy   siolaser you will always have the newest therapy program at your disposal     With the easy to use touchscreen and the built in basic therapy set  you can immediate    ly proceed with treatment  Every programme can be adapted for your individual therapy  needs  Furthermore  you can purchase special therapy sets and easily install them into your  Physiolaser     Thus  the Physiolaser   Photonic Satellite is suitable for a wide range of treatments in der   matology  rheumatology  orthopaedics  physiotherapy  sports medicine     Th
4. al     Readjustment  calibration and maintenance or repairs should only be performed by the  retailer  otherwise the guarantee expires  Any alterations or interventions on the device by  an unauthorized third party void the guarantee  The manufacturer guarantees replacement  parts for a period of ten years after the date of purchase     Disposal   Probes and control units may not be disposed of along with normal electronic waste be   cause of the radiation hazard  The devices should be sent to the manufacturer for decom   missioning and disposal       Manufacturer   Distributor          EN ISO 13485    V 1 2  25 05 2012    Distributor    REIMERS  amp  JANSSEN GmbH  Photomedicine     Laser Therapy    Fabrikstr  22 79183 Waldkirch  Germany  Tel   49 7681 4934149 Fax  49 7681 4934149  service rj laser com www rj laser com    Quality Management ISO 13485  2003   AC 2003    
5. ase speed up       Reset individual settings  With    Reset    you can get back to the origi   nal settings        With    Reset     circle  all individual settings  will be deleted        Start the therapy  After all forms are selected start the thera   py with the button    Start        Prior to the start of the laser beam a two  signal  beep  will indicate that the laser now  will be in use     y  situ     You can   Stop    the start e g in case if some   one  forgot to waer goggles  7 4          With the button    Start    the laser beam will  be activated with presetted power and time     The therapy mode    Prior to the therapy please wear       protection goggles     After the beep  the theraapy screen appears  with the treatment programs and all the set  parameters     During the therapy  a short beep willbe an   nounced every fifteen seconds  The timer  will count down to zero  and the administe   red amount of energy increases        A long beep will be announced once the   therapy time is reached  The current treat  Upper yellow part of the therapy screen   ment can be aborted at any time by pressing shows the active laser with all settings       Stop     Lower part remains blue because no probe  was connected     During the treatment googles must be worn  by staff and patients  Only goggles that are  marked according to EN 207 may be used   The effective wavelength range of the filter  lenses must include the wavelength of the    Photonic 500 and connected probes 
6. e focussed laser beam of the Photonic Satellite can directed as a point  line  or circilary   Such forms can be changed easily to any larger area to be treated with optimal dosage     Photonic 500  Two in one    Static and movable forms   On the Physioalser screen   Select Form   you can choose between stable fixed and  three movable forms     The fixed forms offer a circle  a vertical ho   rizontal line and apoint     The movabale forms offer a filled circle   oscillation  a square  the line moves up and  down on an rectangle        Once you tip to the form you will reach  the screen    Adjust Photonic     where you  can change the basic form and speed of the  movement     Please note that the form    Point     will generate heat and this can lead    to overheating the skin  especially  pigmented skin  Reduce the power    and treatment duration           On the screen    Select Form    you will find    the fixed stable forms in the upper line and  the movable forms in the lower line     Change expansion   On the screen   Adjust Satellite    you can  change the amplitude size of all forms ex   cept the point     Witht he arrow buttosn you can change the  size of the form for horizontal orvertical   dimension  For example you may change  the circle to an ellypse    The pilot beam   lt 5mVV  control lamps on       top of the housing will be active during the     setting  The screen   Adjsut Photonic    with active     amplitude    function  The circle was stret   ched verticall
7. y        Change position  Move the position to different areas without    moving the housing with the aaow buttons     Reset will jump back to normal        Active    Position    allows to move the form    to laft or right     Movable forms  Movable forms can be adjusted in the    amplitude  position and speed  press button   Speed         Please use the plus minus buttons to im   crease or decraease the speed of the laser  beam        With   t     and        the speed of the laser  beam movement can be changed     Turning knobs   Instead of the arrow buttons you can adjsut  all features with the turning knobs  this is  probably much faster and easy to do     Once you have selected    Amplitude    or     Position    the knob will change vertical and    horizontal  axis    In case the   Speed  is active  the knobs offer       the same function as above     Left turn slows down and right turn increa  The left button will change the form in re   ses the speed  gard to the Y axis and the right knob the  X axis        Function of arrow buttons  turning knobs                         El X Achse EJ    Active refers to left refers to right    Vertical button Horizontal button  Function knob knob    Upper  Left   PP  Turn right     Turn left  vertical stretch horizontal upsetting  Amplitude  Lower  Right         Trun left   Turn right  vertical upsetting horizontal stretch    Upper  increase Left   PP Turn left Turn left  slow down  Speed  lower    Right     Turn righ Turn right  decre
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Maglite JS4DH06 Instructions / Assembly  Gateway 30 inch LCD TV Flat Panel Television User Manual  Betriebsanleitung Mode d'emploi Istruzioni per l  Lexmark 1200 Series Setup Sheet  60007 MANUAL (tri).qxd  AOpen AX4PER (91.8AE10.001) Motherboard  Hamlet HDMI - micro USB F/M  Samsung Galaxy Core Prime LTE Manual de Usuario  JVC KD-SX950 User's Manual  Rogue™ Player Software    Copyright © All rights reserved. 
   Failed to retrieve file