Home

User Manual - Pro Audio Centre

image

Contents

1. the parts carefully e Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 amp Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements Innovation Quality Performance
2. to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB 8 of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy controller 1 Check the LED for the response of the master slave mode signal 2 Check if the unit is receiving DMX signal and cut it off D No response to the sound 1 Make sure the fixture does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone E One of the channels is not working well th The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 8 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics e Clean with soft cloth using normal glass cleaning fluid e Always dry
3. LED BR10 User Manual Professional Entertainment Technolo TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 Installation 4 How to Control the Unit 4 1 Control Panel 4 2 Master Slave operation 4 2 Easy controller 4 4 Universal DMX controller 5 DMX 512 Configuration 6 DMX 512 Connection 7 Trouble Shooting 8 Fixture Cleaning WARNING 1 Safety Instruction N Please read the instruction carefully which including important information about the installation operation and maintenance Please keep this User Manual for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Unpack and check carefully there is no transportation damage before using the unit Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock The unit is for indoor use only and use only in a dry location The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Disconnect mains power before fuse replacement or servicing Replace fuse only with the same type Make sure there are not flammable materials close to the unit while operating as it is fire hazard Use safety cable when fixes this unit Maximum ambient tem
4. inking fastopen 158 174 Blue White Rotation 4 4 Universal DMX Controller Open 142 157 Green White 010 120 When using a universal DMX controller to control the chain of units you have to set DMX i 008 131 otation Stop 000 009 000 009 address by Dip switches from 1 to 9 to make sure all the units will receive its DMX signal The dip switch 10 is used to choose channel mode Please refer to the following diagram 6 DMX 512 Connection to know how to address your DMX 512 system in the binary code The DMX 512 is widely used in intelligent lightings and with a maximum of 512 channels DMX 512 Address Chart vae 1 2 4 8 te x 4 126 266 tight show JOOAOO8000 Examples a SOO0000000 DMX INPUT aes DMX OUTPUT Unit 1 dip on 1 1 DMX ee o a DESCODNCOR Unit2 dip on 2 3 2 4 6 ON 12345678910 Termination reduces signal errors and avoids signal Unit 3 dip on 1 2 4 1 2 8 11 JUAUPRAAS transmission problems and interference It is always ee Unit 4 dip on 5 16 ON 12345678910 advisable to connect a DMX terminal R 16 l pannan Resistance 120 ohm 1 4W between pin2 DMX and ON 12345678910 pin3 DMX of the last fixture COMMON 1 If you using a controller with 5 pins DMX output you need to use a 5 to 3
5. perature is TA 40 C and dont operate it where the temperature is higher than this Unit surface temperature may reach up to 60C Don t touch the housing bare hand during its operation There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs by yourself In the unlikely event your fixture may require service please contact the nearest authorized technical assistance center and always use the same type spare parts Don t connect the device to any dimmer pack or power pack Do not look directly at the LED light beam while the fixture is on The housing must be replaced if they are visibly damaged Do not touch any wire during operation as high voltage might be causing electric shock For power supply do not connect in series much more than 20 units use another mains supply for next 20 units 2 Technical Specification e t can be operated by DMX512 control or can be used as an individual unit without controller e Please use a 3 pin XLR cable plug when link in master slave mode e Smooth 0 100 dimming and variable strobe speed e 5 Channels Channel 1 Pan Channel 2 Barrel Channel 3 Strobe Channel 4 Color Channel 5 Dimmer e Voltage AC 100 240V 50 60Hz e Fuse T 2A e LED 1 x10W LED e Power Consumption 23W e Dimension 311 x 135 x 170 mm e Weight 3 4kg 3 Installation The unit should be mounted via it
6. pin adapter cable 2 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of the next unit The cable can not be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables solder joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when power is connected to the unit 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 512 usually O amp 1 are equal to 1 6 The end of the DMX 512 system should be terminated to reduce signal errors 7 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin 4 5 Not used 7 Troubleshootino Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The fixture does not work no light 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector B Not responding
7. s screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 4 How To Control The Unit Dip switches For different function setting Only for remote control Connecting with CA 8 CA 9 CA 9RTX to control the unit for Stand by Function and Mode function DMX output For DMX512 link use 3 5 pin XLR plug cable to link the next unit DMX input For DMX512 link use 3 5 pin XLR plug cable to input DMX signal Power Connect to supply mains power 0000 MO Microphone Receives the sound to control the unit 4 2 Master Slave Operation The unit can be linked together in daisy chain as many as you need in master slave mode to perform the great built in pre programmed lighting shows triggered by music In Master Slave mode refer to the DMX settings below Master unit DMX start address MUST be set to 001 First DIP switch ON all others are OFF Slave units DMX start address may have any value but NOT 001 example set the first 3 DIP switches to ON 2 Light Sho
8. w Dipswitch 10 off means the unit works normally and on means 2 Light show In order to create a great light show you can set dip switch 10 on on any unit that is linking to the master unit to get contrast movement to the master unit even if you have two units only Dipswitch 10 on the first Master unit is no use for the 2 light show as it is the master unit that operates the light show 4 3 Easy Controller by CA 8 CA 9 CA 9RTX The easy remote control is used only in master slave mode By DMX Configuration 5 Channel mode CIR TE ma mao ram Barer mo com Omar 255 246 255 Stop 240 255 Open 241 255 Red Green Blue White 200 100 7 Random 225 240 Green Blue White Stand by Blackout the unit 232 239 strobe 208 224 Red Blue White R connecting to the 4 pin jack of the first unit you will find that the remote controller on the first unit will control all the other units for Stand by Function and Mode selection 182 189 140 181 121 134 125 141 Green Blue 108 124 Red White 092 107 Red Blue 075 091 Red Green 058 074 White 042 057 Blue 025 041 Green 008 024 Red 000 007 Black Out Stop Fast close slow open Open T 132 139 232 239 Open 192 207 Red Green White 1 Synchronous Strobe in id white Select Show Function Select Color 2 Sound strobe in white 1 6 3 Sound Strobe in color T 190 231 Slow close 175 191 Red Green Blue Strobe LED OFF Show LED ON LED bl

Download Pdf Manuals

image

Related Search

Related Contents

Augmentation of Nuclear Medicine Department with PET    QTP 22 - QTP 24  BT ー40  Configure the Controller    Guía de configuración Cámara IP - Psn  KENMERKEN INSTALLATlE GEBRUIKSAANWIJZING  HomeVent® RS-180 Istruzioni per l`uso  Operating Instructions DC CABLE DMW-DCC3/DMW  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.