Home
PX Developer Version 1 Operating Manual
Contents
1. Cl TEE Note that the CAUTION level may lead to serious consequences according to the circumstances Always follow the precautions of both levels because they are important for personal safety Please save this manual to make it accessible when required and always forward it to the end user Startup Maintenance Precautions N CAUTION e The online operations have to be executed after the manual has been carefully read and the safety has been ensured Failure to do so may cause a miss operation which results in machine damage or an accident A 1 A 1 e CONDITIONS OF USE FOR THE PRODUCT e 1 Mitsubishi programmable controller the PRODUCT shall be used in conditions 2 A 2 e i where any problem fault or failure occurring in the PRODUCT if any shall not lead to any major or serious accident and ii where the backup and fail safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem fault or failure occurring in the PRODUCT The PRODUCT has been designed and manufactured for the purpose of being used in general industries MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY INCLUDING BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT WARRANTY TORT PRODUCT LIABILITY FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT
2. 18 3 Foe Role name HAS Paiste 1 Enme o o ES ow Po toto fo fot 3 Operators O O Of Oo x x 4 Opmo2 O O OT x x x 5 Operators OO x Tx x x O Operation permitted x Operation prohibited C JWUserDef File Tool Help od d sd UG admin User Role Auth CommentList RolelD RoleName Set the authority ID which permits the operations for each role MELSOFT B 9 APPENDIX MELSOFT 3 Set a user name a password and a role on the lt lt User gt gt tab oet the same user name password and role as the user setting in the monitor tool LN JWUserDef File Tool Help User Role Auth CommentList admin User04 User03 User02 User01 Set a role for each user l l l l lt I The authority which corresponds to the lock mode of the monitor tool is the GUEST mode in JoyWatcherSuite The GUEST mode is the status of execution of log in operation with the GUEST mode or that of log off operation e Set the same user name and password on the user setting of the monitor tool and JoyWatcherSuite B 10 B 10 APPENDIX MELSOFT 2 JWEdit As security when writing numerical values to the process control tag items check the Enable check box of Object property and set the authority ID required for operations to control valid invalid of mouse operation Exam
3. MITSUBISHI Ten A V ELECTRIC Engineering Software PX Developer Version 1 Operating Manual JoyWatcherSuite Interactio SW1D5C FBDQ E SW1D5C FBDQMON E e SAFETY PRECAUTIONS e Always read these instructions before using this product Before using this product thoroughly read this manual and the relevant manuals introduced in this manual and pay careful attention to safety and handle the products properly The precautions given in this manual are concerned with this product For the safety precautions of the programmable controller system refer to the User s Manual for the CPU module In this manual the safety precautions are ranked as NWARNING and NCAUTION Indicates that incorrect handling may cause hazardous conditions N WARNING resulting in death or severe injury Indicates that incorrect handling may cause hazardous conditions N CAUTION EAD did resulting in minor or moderate injury or property damage o
4. Savein OF em Input a file name and click the Save button My Recent Documents e File name Server JDD Save astype Setting file id amp My Network Caor 4 A new database is created Right click IO in the tree and click New from the menu ename Delete Del New Logical table New Folder J To the next page 3 BASIC OPERATION MELSOFT From the previous page l Drivers Ea 5 The Drivers dialog box is displayed 1 0 0ld Versions Select MELSEC PX Developer PX cH MELSEC mE Data Library m PX Developer era PX Developer m RS 232C o m UDP aM OMRON zm YOKOGAWA Bite JT Engineering m ial Advantech alll FUJI electric 0M HITACHI ml JTEKT xl KEYENCE Developer and click the OK button Melsec PX Developer 6 The driver definition dialog box is displayed Name Input a name and note Note When using the virtual PLC mode check the IO Emulation check box Click the OK button IO Emulation TEZENN i 7 A driver is created under IO in the tree DASSEL Right click the created driver PX DRIVER EI mM for this example and click New from the Rename m e n u Delete New Logical table New Folder Create a new IO area T Melsec PX Developer x 8 The device area setting dialog box is Name displayed Note Input a name and note Interval msec e Input a samplin
5. Password Notification delay JoyWatcher Suite MELSEC PX ALARM MELSEC PX Event Log Log table Delete Log Log Inc Tag Server ID Conversion file Auto ack 3 26 eme 0 LOCALSSHARED P wORDT VALUE 2 w D Documents and SettingssAll LIsersNDocumentssJ TESJoyw atchersP EVENTDIC t t MELSOFT Set a table to store the PX Developer event information in the lt lt MELSEC PX Event tab Input a table name for Log table and click the Create button Set a tag to notify event changes to the alarm monitor Click the Log Inc Tag button 10 The Tag select dialog box is displayed Select the common memory device created in Section 3 5 2 in the tree SHARED PX for this example Click WWORD1 in the tag selection list displayed in the center and double click VALUE from the list on the right The selected tag name is displayed in the above edit box Click the OK button 11 The settings in the Tag select dialog box are reflected on the Log Inc Tag edit box 12 For setting other items refer to the next page 13 Click the OK button Tocreate a log table start the server control Touse the Tag select dialog box start the server control To operate with the monitor toolbar check the Auto ack check box in each tab 3 26 3 BASIC OPERATION MELSOFT DISPLAY SETTING SCREEN Security manager Security man
6. TO Bisiconsd sosucuitdetaet aestate seat Sind contu Bu sont oae A 11 TROUBLESHOOTING iiini 4 1 Troubleshooting related to the communication function regarding process control tag names Fe a EA EEE E E E EEE 4 1 Troubleshooting related to the alarm integration TUNG WOW masina bared as RN 4 2 Windows is a registered trademark or registered trademark of Microsoft Corporation in the United States and other countries JoyWatcherSuite is a trademark or registered trademark of JT Engineering inc All other company names and product names used in this manual are trademarks or registered trademarks of their respective companies SH NA 080976ENG D 1507 KWIX MODEL SW1D5C FBDQ O JYWS E MODEL CODE 13JU70 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice
7. 10 Organized data process condition data process status data attached to DDC processing which is indicated by process control tag Accessing this process control tag data allows monitoring and condition setting of a corresponding DDC processing Process control tag data item Each data item that makes up process control tag data Tag FB A function block works as a controller or an indicator containing tag data Process control tag data Gauge window on which an indicator such as a controller is displayed in image format Values assigned to tag data are manipulated Setting value Faceplate PV Process variable Manipulated variable mdb file which is created when compilation is executed in the programming tool This file stores assignment information of variables for storing data such as tag data and device information of the CPU module Assignment information database 1 OVERVIEW MELSOFT 1 OVERVIEW 1 1 1 Overview In addition to the basic monitoring function of the monitor tool outstanding and easy to use JoyWatcherSuite development monitoring environment can also be available by using the interaction function of the PX Developer monitor tool and JoyWatcherSuite SCADA software manufactured by JT Engineering inc This function supports the following four interaction functions 1 2 3 4 Incorporating faceplate control Communication function using process control tag names Reference function f
8. Developer Referenc monitor tool on JW Edit of JoyWatcherSuite Paste set faceplate control p Section 3 4 e Set showing faceplate from object Operating procedure 4 Set to display alarms and events of the PX Developer monitor tool on Alarm Monitor of Reference JoyWatcherSuite e Set the database settings dai section 3 5 e Set the security manager e Set the alarm monitor Operating procedure 5 Set to perform interactive start stop of the PX Developer monitor tool on Reference JoyWatcherSuite Set the interactive start stop setting Section 3 6 Operating procedure 6 Execute JWPanel of JoyWatcherSuite A 9 A 9 GENERIC TERMS ABBREVIATIONS AND TERMS The following table shows the generic terms abbreviations and terms in this manual 1 Generic terms and abbreviations Generic term abbreviation Generic term for PX Developer Version 1 SW1D5C FBDQ E and PX Developer Monitor Tool SW1DNC FBDQMON E For PX Developer Programming Tool and Monitor Tool are installed For PX Developer Monitor Tool only Monitor Tool is installed Programming tool Abbreviation for PX Developer programming tool Monitor tool Abbreviation for PX Developer monitor tool Abbreviation for Operator Station Abbreviation for Operator Station 0 system interacting with multiple OPSs Abbreviation for a monitor tool which starts up as Client in the server client monitoring system interacting with multiple OPSs JoyWatcherS
9. JWRepAssistant AnyProgram EXE ConfigurationF ile AnyProgramArguments JoyWatcher Suite Launcher Task SecurityManager StartUp StartSchedule DisableTask StartUp WaitTime sec 0 z Endintegration StartSchedule 3 34 Finish 1 Cancel Click All Programs JoyWatcher Execution from the start menu and click JW Launcher while holding down the Shift key to start JWLauncher The JoyWatcher Suite Launcher screen is displayed Right click Add Task and click NewTask from the menu The setting dialog box is displayed Select SecurityManager for Start Program and click the Next gt button 4 The setting dialog box is displayed e Select StartUp e Check the EndIntegration check box Click the Finish button 3 34 4 TROUBLESHOOTING MELSOFT 4 TROUBLESHOOTING 1 Troubleshooting related to the communication function regarding process control tag names This section explains troubleshooting for failures possibly occur in relation to the communication function regarding process control tag names Trouble Cause corrective action Reference While JWPanel is in operation the monitor data Although the process control tag data in PX Developer are changed while JWPanel is in operation the monitor data do not change The following are the possible factors The monitor tool is not
10. Recivered Date 11 EV_VALUE 00 STRING Mesured Value 12 EV_RVALUE 00 STRING Recoverd Value sEv UsERDEorNUM user Color Table Create eo 2 o MM DD R 1f 0 No convert No convert STR Filter 12Minor 22Moderal No convert O oO uo MM DD R Of MM DD R 1f MMDD R 1f MWDD R 1f MM DD R 1f Talr e No convert D BR o a e No convert T0399 3393213 7123 Pe u e No convert r r MM DD R 1f r Show line numbers Back Enisn Cancel 3 31 3 31 3 BASIC OPERATION MELSOFT 3 6 Operation to Perform Interactive Start Stop of PX Developer Monitor Tool on JoyWatcherSuite PURPOSE In order to interact between the JoyWatcherSuite server and the PX Developer monitor tool the PX Developer monitor tool needs to be started before starting the JoyWatcherSuite server By performing the MELSEC PX interact setting using JWLauncher the PX developer monitor tool can be automatically started before starting the JoyWatcherSuite server To use the alarm integration function the security manager needs to be started after starting the JoyWatcherSuite server By using JWLauncher the security manager can be automatically started after starting the JoyWatcherSuite server e Setting on JoyWatcherSuite Procedure 1 Set the MELSEC PX interaction on JWLauncher gt Section 3 6 1 Procedure 2 Register tasks of s
11. displayed in the tree Only current value collection targets and process control tag items for event notification are displayed in the lt lt Main gt gt tab All process control tag items are displayed in the lt lt All gt gt tab Select process control tag items to be used in JoyWatcherSuite from the tree and click the Add Row button The selected process control tag items are displayed in the table at the right Change the tag name comment or unit to be used in JoyWatcherSuite as necessary Click File Save As from the menu The Save As dialog box is displayed Input a file name and click the Save button The file extension is txt The files saved at this point defined files are required for server designing and execution of JoyWatcherSuite 3 BASIC OPERATION MELSOFT e Since the maximum number of characters for a JoyWatcherSuite tag name is 64 a long process control tag name set in PX Developer is indicated in 46 characters and a serial number 5 digits Characters that cannot be used for process tag name in JoyWatcherSuite are replaced with the character applicable to JoyWatcherSuite I I are replaced with e The MELSEC PX tag selection function refers tag information from setting data of the monitor tool PX Developer tags to be referred are tag FBs process control tags of all supported projects registered in the monitor target project setting
12. of the monitor tool Even when the information of PX Developer project tag FB is changed and compiled again after starting the MELSEC PX tag selection function it is not reflected to the process control tag list on MELSEC PX tag selection Read the project with PX Developer monitor tool again save the set data and restart the MELSEC PX tag selection function e If the tag list is not displayed the following are the possible causes 1 The setting data file in the monitor tool is one of the old versions 2 A setting not supported by the monitor tool of the versions concerned is included in the setting data file of the monitor tool As each countermeasure perform the followings 1 Refer to Version Compatibility in PX Developer Operating Manual Monitor Tool and convert the setting data file 2 Refer to Version Compatibility in PX Developer Operating Manual Monitor Tool and check the supportability of the setting data file 1 For checking whether the project is supported refer to Monitor Target Project Setting in PX Developer Operating Manual Monitor Tool 3 BASIC OPERATION MELSOFT 3 3 2 Server design BASIC OPERATION 1 Click All Programs JoyWatcher Basic Setting JWDesign from the start menu to start JWDesign CE ad 2 The JWDesign screen is displayed S open ae Click File New from the menu New Database 3 The New Database dialog box is displayed
13. rose i Reeve de dee ie dia 3 4 39 2 SEVO designbaas TE LER 3 6 3 3 3 Referring to and selecting process control tAGS cccccscccsseseeeeeeeeeceeeeeeeeeeeeessuaeseeeeeeessuaaseeseees 3 9 3 4 Operation to Use Faceplates of PX Developer in JoyWatcherSuite ccccccccccsssseeeeeeeeeeeeeeeees 3 12 3 4 1 Pasting setting faceplate CONHIOL cccccccssssseceeeecesseeeeeeccceeausseceeeecesaesaeeeeeeeseeeaaaeeeeeeesseaasssesees 3 13 3 4 2 Setting of showing faceplate from object cccccceeeseececeeeeeeeeeeeeeeeeeeeaeeseeeeeeeseuaeseeeeeeessaaaaeees 3 15 3 0 Operation to Display PX Developer Alarm Event Information on Alarm Monitor of JOVVV aECner HE ratones cer Rese bobina tonum Ma Bue onary Ut oce ere 3 18 3 5 1 Configuring database settings 5d rre ee re eee s Eee eo eerte crt Poe e tete desees 3 21 9 0 2 SENE GESIG Oe ee ee ee eee eee eee eee eee me ee 3 22 3 5 3 Setting security manager EET T 3 25 294 SEMN alarm MONO isr a E ee a 3 29 3 6 Operation to Perform Interactive Start Stop of PX Developer Monitor Tool on JoyWatcherSuite 3 32 3 6 1 Setting interactive start stop of monitor tool ee eeecccceeecceeeeeeeeeeeeeeeaeeseeeeeeeeesaeeaeeeeeeeeesaaeaeees 3 33 3 6 2 Setting interactive start stop of security manager sese 3 34 A 4 A 4 4 TROUBLE ZOOM r 4 1 APRE NODA Gee eo coeur uL Lu UM cu MU E MU EE B 1 Appendix 1 D
14. started The JoyWatcherSuite server control is not started The assignment information database to which the relevant process control tags are registered is not registered to the monitor target project of the monitor tool The relevant assignment information database is registered to the monitor target project of the monitor tool after starting the monitor tool Section 3 1 or JoyWatcherSuite server control Check if JWPanel is executed by the following procedure 1 Start the monitor tool 2 Register apply the relevant assignment information database to the monitor target project of the monitor tool 3 Start the JoyWatcherSuite server control 4 Start JWPanel The following are the possible factors The monitor tool is not started The assignment information database to which the relevant process control tag is registered is not registered to the monitor target project of the monitor tool The monitor tool is in communication error The user who is operating the monitor tool does not have the authority of operation for changing the tag data items l Ge Section 3 1 Check and set the following items Check if the monitor tool is in operation Check if the process control tag exists in the monitor target project of the monitor tool Check for the communication error from the list of PX Developer alarms Switch to a user who has the authority of operation for changing the process control tag data
15. DD R96 1f MM DD R 0f MM DD R 1f MM DD R96 1f MMDD R 1f MM DD R 1f MMDD R 1f ok 0 No com 0 No com 0 No com 3 STR Lo 0 No com 0 No con 0 No com 0 No com D No com 0 No com 0 No com 0 No com f Nn rnm Y Showline numbers XS BCE eco MELSOFT 5 The settings in the Tag select dialog box are reflected on the JoyWatcher Tag edit box Click the Next gt button 6 The EventSummary MELSEC PX Alarm screen is displayed Select the log table created in Section 3 5 3 from the data table list box and click the Generate button 7 The Column screen is displayed Set details of the displayed items and click the Finish button Configure the settings for data type MELSEC PX Event with the same procedure 3 30 3 30 3 BASIC OPERATION MELSOFT The following shows the setting example to arrange the display as same as the monitor tool aox is Column Mauca ia Edit Column W cor Trevi mnom eRveRO SEV_CONFIRMDUSTRING conrm Ev Pont OUSTRING rao wem cneeke Datee Num FormfstrFormat option feoir 30 T MMIDD R 1f No convert oo e MMDD R 1f MM DD R 1f MM DD R 1f MM DD R 1f MM DD R 1f No convert 0 D No convert 0 0 0 Oo MM DD R 1f 3 STR Lookup N Normal E Occe I 0 4 D D D 0 No convert No convert No convert 10Ev caPTIONoGSTRNG rao Comment OSTRING Alarm Contents OSTRING Status 3 Datetime Occurrence Date
16. DISPLAY SETTING SCREEN Screen to display set items 2 DISPLAY SETTING DATA Explains items in DISPLAY SETTING SCREEN Informs items to be noted and useful functions relevant to the contents in the chapter or section The following table explains symbols in this manual and their description Expresses an item in a window or dialog box or a menu on the menu bar 5 expresses the drop down menu Example File Save As Expresses a corresponding button C Example Select button PES Expresses dialog box tab Example MELSEC PX ALARM gt gt tab MANUAL ORGANIZATION This manual consists of four chapters and Appendix This manual is organized assuming that the interaction function of the PX Developer monitor tool and JoyWatcherSuite are utilized in the following procedure lt Procedure for utilizing the interaction function with JoyWatcherSuite gt Operating procedure 1 Set PX Developer projects to be monitored Es on the PX Developer monitor tool ererence Section 3 2 e Set monitor target projects PX Developer Operating Manual Monitor Tool Operating procedure 2 Using the tag name reference function of JoyWatcherSuite assign process control Reference tags of PX Developer to the tags Register process control tags to be used e Set the settings to communicate with PX Developer Section 3 3 Set process control tags to be monitored Operating procedure 3 Paste faceplate control of PX
17. Developer in JoyWatcherSuite sueeuuusss 3 12 P Pasting setting faceplate control 3 13 Personal compulter sssssse A 10 Process control tag ssssssssee A 10 Process control tag data A 10 Process control tag data item A 10 Programming tool sssssssse A 10 PY sedaner lta sieut rimis ibd A 11 PX DevelODGL scusen shut etctanat unt odas idi Roa giaud a A 10 R Reference function for PX Developer process control tag NAMES cccceeeeeeeeeeeeeeeeeeeeees 1 1 4 Referring selecting process control tags 3 9 Registering process control tags 3 4 S Security of Monitor Tool and JoyWatcherSuite ddp esM M M MM AE E AEA B 6 Security Manager eeeeeseeese A 10 Setting alarm monitor 3 29 oetting interactive start stop of monitor tool rc 3 33 Setting interactive start stop of security manager Pn 3 34 C 1 Setting of showing faceplate from object 3 15 Setting monitor target projects 3 2 Setting security manager 3 25 Software Configuration 2 3 I A 11 SYSTEM CONFIGURATION 2 1
18. IC OPERATION 3 5 4 Setting alarm monitor ES BASIC OPERATION z AlarmMonitor PES File Config Help iHd Config Ll f Database E EventSummaryiMELSE Select Database select data type a SaL Database j Etc DSN f Show Line no USER Color Print PWD Type Auto refresh C ALARM LOG JWServer JoyWatcher Alarm C EV LOG Old Eventmangen Event Summery MELSEC PX Alarm C User DB C Scheduler JWScheduler C MELSEC PX Event CS ity Lo iv Tag value change Auto popup Tag select LOCALSSHARED_PX WORDOS VALUE LOCAL SHARED PX PX TAG To the next page MELSOFT 1 Click All Programs JoyWatcher Editor EvGridMon from the start menu to start the alarm monitor 2 The AlarmMonitor screen is displayed Click the Config button The Database screen of the Config dialog box is displayed e Input for DSN under Database e Select EventSummary MELSEC PX Alarm for Data type Check the JoyWatcher Tag check box Click the tag select button E The Tag Select dialog box is displayed Select the common memory device created in Section 3 5 2 in the tree SHARED PX for this example Click the same tag set for Log Inc Tag in the MELSEC PX ALARM of security manager WORDO for this example in the tag selection list displayed in the center and double click VALUE from the list on the right
19. IC OPERATION MELSOFT 3 3 3 Referring to and selecting process control tags ES BASIC OPERATION FY JoyWEdit JoyWatch1 Edit View Object Format Debug Window Help D cr fed aa amp 5 k G noc c e GN SH Glam A 5 4 A BN p JoyWatch1 Height For Help press F1 X 0012 0196 Step 00000 Scale 100 FY JoyWEdit JoyWatch1 File Edit View Object Format Debug Window Help Deh X355 08 2 Sar CK RIG ho 4 4 SG py OSG lat A DAs Ch th C LAAs OLA BEF S B JoyWatch1 operties Pri BE PosSize Left Top Width Height amp Line Color Style Width Pine v For Help press F1 X 0337 0151 Step 00001 Scale 100 Object property EN E Ge Direct irec m A ordin Direct Condition gi nde iia Los ils Ell Pos Left x Center x Edge None m Effect Noma Ow Font Shadow Cool _yijLe Kd Extend Definition Apply To the next page 3 9 1 Click All Programs JoyWatcher Editor JWEdit from the start menu to start JWEdit The JoyW Edit screen is displayed Click the Text button A Place the text object on the process view and double click it IN The Object property dialog box is displayed Check the Enable check box in the text property Click Text Direct in the tree 3 9 3 BASIC OPERATION MELSOFT From t
20. INTENDED OR EXCLUDED BY INSTRUCTIONS PRECAUTIONS OR WARNING CONTAINED IN MITSUBISHI S USER INSTRUCTION AND OR SAFETY MANUALS TECHNICAL BULLETINS AND GUIDELINES FOR the PRODUCT Prohibited Application Prohibited Applications include but not limited to the use of the PRODUCT in e Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT e Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User Aircraft or Aerospace Medical applications Train equipment transport equipment such as Elevator and Escalator Incineration and Fuel devices Vehicles Manned transportation Equipment for Recreation and Amusement and Safety devices handling of Nuclear or Hazardous Materials or Chemicals Mining and Drilling and or other applications where there is a significant risk of injury to the public or property Notwithstanding the above restrictions Mitsubishi may in its sole discretion authorize use of the PRODUCT in one or more of the Prohibited Applications provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail safe redundant or other safety features which exceed the general specifications o
21. ION MELSOFT 3 5 1 Configuring database settings 1 Click All Programs JoyWatcher Basic Setting JWDesign from the start menu to start the server design The JWDesign screen is displayed Click Setting Database from the menu a Design D Documents and Settings Administrator My Documents JW_Data Server JDD di B ug 2 File ESSERE window Help D Password gt 1 Table maintenance aa OTY ff4 PX TAG EB LOGICAL D Documents and Settings Administrator My Documents JW_Data Server JDD ageun eninbree beriz S5 TED x 3 The External database basis setting dialog box Server name E ud is displayed Data source Input a server name Eun name e Input for the data source name PWD TUE Click the Create JWDB button Click the OK button Storage time Day 78 Design D Documents and Settings Administrator My Documents JW_Data Server JDD AR z EEE 4 Click File SaveAs from the menu D New CtieN Pag Open Ctr o El Save Ctrl 5 ae ER 5aveAs Undo edit Recent file Use server Exit D Documents and Settings Administrator My Documents Jw DatalServer JDD 3 21 3 21 3 BASIC OPERATION 3 5 2 Server design File Setting Window Help Dad SEO Delete New Logical table New Folder D Documents and Settings Administrator My Documents JW DatalServer Drivers 1 0 Old Vers
22. LS soree iaa E E IA DEM MIU dM I MUI iM LE EM A 6 HOW TO USE THIS MANUALE itia eui debutto cd aus dues a tosta ttu ne do eben tuna ds A 7 MANUAL ORGANIZA ON A 9 GENERIC TERMS ABBREVIATIONS AND TERMS 0 ssseeeceeeeeeeeeeeeeeeeeeasssssseeseeeeeeeeeeeseneaaaas A 10 1 Re eae acre cheese eb eateanes m T PM UE Eu PU Nea ald eae 1 1 1 1 OVET VIG W E N EE N EEEE PO OE EE Por rout PAR AEA AE E A AO E fo cie aola 1 1 1 2 EEEE iN E P EA E AE EE I then P I IE A E E E A E E A NS NC E OE E 1 2 2 SYSTEMIC ONEIGU RA HON cicus e Bac aaa anean Dan aaa a ee a e e Pe onda 2 1 2 1 oVSLIemat oH IF OE enea a a dite ditus 2 1 2 2 SOnWare COMIGUFATION TER TE T he hk ese ee ae eee 2 3 2 3 CoperaunpgAEnviFOBfie E sssoaecen timeo op a dria deett a re edes hate dibabs 2 4 3 BASIC OPERATION hito iedt aces ee iae tiep Ed pL icc etate rus 3 1 3 1 Operating Procedures for Monitoring on JoyWatcherSuite ccccccccsseeeecceeeeeeeeeeeseeeeeesssaeseeeeeees 3 1 32 Operation to Set PX Developer Projects to be Monitored on Monitor Tool 3 2 3 2 1 Setting Montor target prolecls eno cette th i boob et o ee dem uo Rb a Fd datu cui fessa bb cu ue edad 3 2 3 3 Operation to Communicate using PX Developer Process Control Tag Names in JOVV VALCO Fea UNG ae e5 icat gatas aiid octal iec hat TEE 3 3 3 3 1 Registering process control 180 iret irre ri rete eer
23. Suite a display name item and display format can be selected in the property For details refer to JoyWatcherSuite user s guide PX Developer monitor tool Alarm monitor of JoyWatcherSuite i i Maximum number Alarm item Expression Alarm item Expression characters Confirm Check ON OFF EV_CONFIRM ON OFF Ta FICO01 EV POINT i Example FICOO1 Tank 1 water Tag Comment Tag Comment EV CAPTION level Example Tank 1 water level Alarm Contents Alarm Contents EV USERDEF2 Example MHA Occurrence Date The format EV EDATE depends on the er i Recovered Date setting of OS EV RDATE ormat in the alarm monitor Leve Minor Major EVLEVEL Mimorimapr3 Measured Value EvsD SevriD EVD Seria numbers Event status is saved E Occurrence EV STATUS No correspondence R Recovery C Information EV CODE Lo 35 1E 0 oe o EV RVALUE Lo d 1 blank space EV USERDEF1 SS 1 Characters that are exceeded the maximum number of characters are not stored to the database 2 The description corresponds to Tag Data Item Display of Alarm on the option setting of the monitor tool is displayed 9 EV SID is an ID to distinguish programs which are inserted to the same table EV SID EV ID is a unique ID 4 EV SID is the same as Server ID on the Security manager screen Depends on the setting of date B 3 B 3 APPENDIX MELSOFT Appen
24. The selected tag name is displayed in the above edit box Click the OK button To use the Tag select dialog box start the server control 3 29 3 29 3 BASIC OPERATION From the previous page Config Database Database Etc Show Line no Color Print C ALARM LOG JWServer C EV LOG Old Eventmanger Event Summery MELSEC PX Alarm C User DB C Scheduler JWScheduler C MELSEC PX Event C Security Log Auto refresh JoyWatcher Alarm jv Tag value change Lo CALSSHARED PXWORDS VALUE Auto popup Requery when ack Security amp Lag No Dialog No Dialog No Dialog No Dialog Config H Database EventSummaryiMELSEC PX Alarm BETTE SES JoyatcherSuite EventSummary MELSEC PX Alarm SQL a Color a Column Data Config E Database Column ventSummary MELSE Edit Column i E D Color 1 EV SID D1 NUM 3 EV POINT 00 STRING 30 jv 80 4EV STATUS DO STRING Status v 60 5 EV_CONFIRMOO STRING Confirm M 30 Column 2 EV ID D1 NUM amp EV EDATE 03 Datetime Date bsDateime 13 FV USFRDANIT NUM iu User TEV RDATE 03 Datetime RDate M 80 jv 80 v 40 v 30 jw 30 Iv mn Next Cancel PX_ALARM Max Generate Back secs Cancel Wo VT A A 0 7 7 Color Table Create MM DD R 1f MM DD R96 1f MM DD R96 1f MM DD R96 1f MM DD R96 1f MM DD R96 1f MM
25. VY RIAR RIR Set a user name a password and the authority of users who operate the monitor tool max Authority M Engineer Operator4 Operator3 au Operator2 Operatori Engineer B 7 APPENDIX MELSOFT 2 Setting security function in JoyWatcherSuite Set the following items in JoyWatcherSuite For details refer to JoyWatcherSuite user s guide 1 User setting oet a user name a password a role and the authority of users who operate JoyWatcherSuite When using the security of the monitor tool and JoyWatcherSuite set the same user authority description of the monitor tool and that of JoyWaitcherSuite The following describes an example of JWUserDef of JoyWatcherSuite 1 Set a name of authority ID on the lt lt Auth gt gt tab Set the names of item tag data item change alarm monitor check where the security can be set for operations in JoyWatcherSuite 6 MELSECPXtagexdusivetoengieer CN JWUserDef f Ex File Tool Help Commentlist MELSEC PX ALARMIEVENT confirm MELSEC Px tag Process instruction values Mode MELSEC PX tag Alarm threshold values MELSEC PX tag Tuning parameter values MELSEC PX tag Process design values MELSEC PX tag exclusive to engineer B 8 B 8 APPENDIX B 9 2 Set a role name and an authority number on the lt lt Role gt gt tab Set the user authority Engineer Operator to 4 and the authority ID of the monitor tool
26. WatcherSuite PX Developer process control tag names can be used as tag names in JoyWatcherSuite and process control tag data in the monitor tool can be read from written to JoyWatcherSuite This eliminates the need for managing assigned devices and communicating through a communication driver to read write process control tag data Furthermore high speed response by the event notification receive function and the high speed current value collection function of the monitor tool can be utilized on the monitor screen of JoyWatcherSuite Image of the communication function using process control tag names PV value of i the process Readi er TEN eading writing process I control tag FIC001 g gp Registration of tag with the process control tag name FICO01 PV control tag data High speed current value collection Event notification receive i Unnecessary for reading writing process control tag data Z L LLL dr d ee ur di Without considering assigned devices for the process control tags communications can be performed by registering tags on JoyWatcherSuite using process control tag names defined in PX Developer 1 3 1 3 1 OVERVIEW MELSOFT 3 Process control tag names can be selected easily from JoyWatcherSuite When using the communication function with the aforementioned process control tag name PX Developer process control tag names can be easily browsed selected by MELSEC PX Tag S
27. ager Database Database User User Notification delay Password Password Oa Notification delay D JoyWatcher Suite MELSEC FX ALARM MELSEC PX Event Log Joyw atcher Suite MELSEC PX ALARM MELSEC PX Event Log ID v Log Inc Tag LOCALSSHARED PX WDRDOSVALUE aa a LOCAL SHARED_PX WORD1 VALUE 1 wal L mE Server ID 2 Y Conversion file D Documents and SettingssAll Users Documents JTEWoyWatcher P_EVENTDIC tt Conversion file DAD ocuments and Settings All Users Documents JTE JoyWatcher P_ALSRMDIC txt Auto ack Auto ack MELSEC PX ALARM gt gt tab lt lt MELSEC PX Event gt gt tab E DISPLAY SETTING DATA Database list box Select a database to store alarms events of PX Developer Ln Set an interval of time until changed tags are incremented after data are 2 Notification delay edit box stored to database Set a table to store alarms events of PX Developer 7 3 Log table list box ee The created log table is used for the alarm monitor setting in Section 3 5 4 Set a number of days to keep the logs 4 Delete Log edit box l When 0 is set logs are not deleted l Set a tag common memory device created in Section 3 5 2 to notify 5 Log Inc Tag edit box 49043 alarm event changes to the alarm monitor Set an ID to identify the function storing order when data are stored to the database When a file name is specified ob
28. ata Types of Process Control Tag ltems ccccccccceeeeeeeeeeeeeaeeeeeeeeeeeesaeeaeeeeeeeeessaaaeeeeees B 1 Append 2 Mai Taglenm Szer ee ue oet PE PU n re pest Un n Hue Past ad euo So OUR Leu Le Sedona B 1 Appendix 3 Correspondence Table for Items of Monitor Tool and JoyWatcherSuite B 3 Appendix 3 1 Correspondence table for alarm ItOMS cccccececcccceeeceeeeseeeeeeseeaeaeeeeeeeeesssaaeeeeeeeeeeeeaas B 3 Appendix 3 2 Correspondence table for event items cccccceccececceeeceeseeseeeeeeeeeeeeeesseceeeeessaaaeeeeeeeeeneaas B 4 Appendix 4 Calling Monitor Tool Function from JoyWatcherSuite 0 ccececceceeeeeseeseeeeeeeesesaeeseeeeeees B 5 Appendix 5 Security of Monitor Tool and JoyWatcherSulite eeeessssseeesesesseeeseeeennnenne B 6 Appendix 5 1 Operating environment for using security of monitor tool and JoyWatcherSuite B 6 Appendix 5 2 Setting procedure for using security of monitor tool and JoyWatcherSuite B 6 Appendix 5 3 Procedure for monitoring operation with security interaction between monitor tool and JOY ACNES UNE inia T m A A canes easels res B 13 Appendix 6 Functions Added to and Changed from Old Version cccccsccseeeeeceeeeeeeeeeseeeeeeeeeeseaaaaeees B 14 POEA Sd sdb tue due uL M putet tuti C 1 MANUALS The following manuals are also related to this product Refer to the following table for ord
29. ata base settings on JWDesign gt Section 3 5 1 Procedure 2 Set common memory devices on JWDesign L Section 3 5 2 Procedure 3 Set the security manager L Section 3 5 3 Procedure 4 Set the alarm monitor L Section 3 5 4 e Execution on JoyWatcherSuite Alarms of PX Developer can be monitored on Alarm Monitor of JoyWatcherSuite by executing Alarm Monitor of JoyWatcherSuite after starting the monitor tool Only alarms and events occurred during the execution of monitor tool are displayed on Alarm Monitor of JoyWatcherSuite e The monitor tool and operations verify delete relevant to alarms events managed by JoyWatcherSuite are not interacted Perform the verification of alarms events on JoyWatcherSuite side When Auto ack is checked on the security manager setting the alarm event in the monitor tool is checked regardless of authority of users who operate the monitor tool 3 BASIC OPERATION 3 19 The following shows interaction operation of alarms and events 1 Operating alarm monitor screen The following is an alarm monitor screen of JoyWatcherSuite px alarm jgr AlarmMonitor File Config Help gi HX a i Ductfan LIC112 Ductfan LIC122 LIC122 FIC123 Burner Ductfan LIC112 FIC123 Ductfan FIC123 LIC112 LIC112 FIC110 FIC111 LIC112 FIC111 CI 1 1 1 173717 3731173343111 lt Example of alarm monitor screen of JoyWatcherSuite gt Tag Com
30. cy control tag names Alarm integration function endian names 1 O Validated x Invalidated Installed and not started and not started Monitor tool Server Client C c JoWatcherute sid Sever Qlen Reference function for PX Developer Le process control nm names Faceplate control Faceplate control display Communication function using process control tag names O Validated x Invalidated In noperation Monitor tool Server Client E o E Client JoyWatcherSuite Sewe Reference function for PX Developer o qj process control tag names Faceplate control display GO p Communication function using process 9 Q control tag names 5 dL 0 0 Alarm integration function O Validated x Invalidated 1 Install a monitor tool server or standalone to a JoyWatcherSuite server and install a monitor tool client to a JoyWatcherSuite client 2 Validated only when the monitor tool is in operation on the JoyWatcherSuite server personal computer 2 2 2 2 2 SYSTEM CONFIGURATION MELSOFT 2 2 Software Configuration This section explains software configuration when using the interaction function of PX Developer and JoyWatcherSuite PX Developer JoyWatcherSuite Monitor target Development environment project setting Reference Tag name reference function Monitor tool Operating environment Faceplate control ActiveX contai
31. dix 3 2 Correspondence table for event items The following is a correspondence table for the event items notified to JoyWatcherSuite by the monitor tool In the alarm monitor of JoyWatcherSuite a display name item and display format can be selected in the property For details refer to JoyWatcherSuite user s guide PX Developer monitor tool Alarm monitor of JoyWatcherSuite Maximum number Event item Expression Event item 4 Expression of characters Confirm Check ON OFF No correspondence State is left blank Ta Tag TICO01 EV TagName Example TIC001 Tank Tag Comment EV_TagComment temperature Event Message EV Description Tag Comment Example Tank temperature Event Message Example SV Status Example CAS 90 0 C User Set Value 90 0 C EV Value Server ID EV SID No correspondence 3 EV ID 1 Characters that are exceeded the maximum number of characters are not stored to the database Example admin The format Depends on the setting of date Occurrence Date depends on the EV DATE l format in the alarm monitor setting of OS 2 The description corresponds to Tag Data Item Display of Event on the option setting of the monitor tool is displayed 3 EV SID is an ID to distinguish programs which are inserted to the same table EV_SID EV_ID is a unique ID 4 EV SID is the same as Server ID on the Security manager screen B 4 B 4 APPENDIX MELSOFT Append
32. e without notice HOW TO USE THIS MANUAL ie PURPOSE J Setting on JoyWatcherSuite Describes the purpose of operations for each chapter or section Describes operating procedures 3 3 Operation to Communicate using PX Developer Process Control Tag Names in JoyWatcherSuite D purpose Register tags using process control tag names defined in PX Developer and read write the process control tag data of the monitor tool in JoyWatcherSuite e Setting on JoyWatcherSuite Procedure 1 Register process control tags to be used for MELSEC PX Tag Select 7 Section 3 3 1 Procedure 2 Set the settings to communication with PX Developer by JWDesign 7 Section 3 3 2 Procedure 3 Set process control tags to be monitored on JWEdit L5 Section 3 3 3 e Execution on JoyWatcherSuite The process control tag data can be read written by executing JVPanel after starting the monitor tool animi LLLI mn Hep Eg B bud R Eg B jam l qs zx ies s Ez z 4 IE imeem tmm an Slorage lank Uquid som r E ae ee tlle ime dm i mm a Cold vaker ET T p SaaS m lt Example of JoyWatcherSuite operating environment screen gt b Execution on JoyWatcherSuite Reference location Describes functions to be executed leads to the reference location A 7 There are also the following types of explanations BASIC OPERATION Explains operation methods
33. ecurity manager on JWLauncher L Section 3 6 2 e Execution on JoyWatcherSuite The functions are automatically started in the order of monitor tool JoyWatcherSuite server and security manager by clicking the Start Server button gt on JWLauncher Monitor tool JoyWatcherSuite server and security manager are automatically stopped by clicking the Stop Server button NONAME Joy Watcher Suite Launcher ej CE niue DADocuments and Settingss amp dministratarsMy Documents Serve JD D StartP attern NextRunTime LastRunTime security anadger Statlig lt Example of JoyWatcherSuite JW Launcher gt 3 32 3 32 3 BASIC OPERATION MELSOFT 3 6 1 Setting interactive start stop of monitor tool ET BASIC OPERATION 1 Click All Programs JoyWatcher Execution from the start menu and click JWLauncher while holding down the Shift key to start JWLauncher RONAN Joviiatcher Suite auncher 2 The JoyWatcher Suite Launcher screen is gt eJ m LxJ 9 Le Le Oe displayed Task StartPattern NextRunTime LastRunTime Click the Select JDD button i i J Add Task ServerMode Ed 3 The ServerMode dialog box is displayed ServerMade e Select LocalServer for Server Mode LocalServer Client Redundant Tu e Specify the server design file JDD created C in Section 3 3 2 for Local Server Pediindant Check the Start and Endln
34. elect of JoyWatcherSuite using the tag name reference function This function reduces key inputs and typing errors and improves work efficiency 1 Process control tags that can be browsed selected are tags of the project registered in the monitor target project setting in the PX Developer monitor tool Image of the tag name reference function PX Developer Selection of tags to be used in JoyWatcherSuite PX Developer JoyWatcherSuite programming tool MELSEC PX Tag Select _ Assignment MESE PX ToS information Bux database zoo EH 23 2 s Compilation n reete onn PX Developer Monitor target um monitor tool project setting Tag information acquisition Process control tag names defined in PX Developer can be browsed selected by MELSEC PX Tag Select of JoyWatcherSuite 1 OVERVIEW MELSOFT 4 Alarms events of the PX Developer monitor tool can be monitored on JoyWatcherSuite By using the alarm integration function alarms and events of the monitor tool can be displayed on Alarm Monitor of JoyWatcherSuite This function improves monitoring efficiency Image of the alarm integration function PX Developer JoyWatcherSuite amp operating environment sp on alarms events Management on alarms events Notification of alarms events Notification of alarms events Hu Alarms events of PX Developer can be monitored on
35. ering a manual Related manuals Manual number Manual name model code PX Developer Operating Manual Programming Tool SH 080369E Explains FBD language programming compilation online operations and debug methods with PX 13 JU38 Developer Sold separately PX Developer Operating Manual Monitor Tool p SH 080370E Explains the operation methods of the monitor tool and methods for monitoring and controlling DDC 13JU39 processing with tag FB Sold separately PX Developer Programming Manual Explains details of programming with PX Developer lists of FB parts and the PID instructions SD Sold separately Please note that we do not guarantee commercially available software compatible with Microsoft Windows Operating System introduced in this manual The software copyright of this product belongs to Mitsubishi Electric Corporation No contents in this manual can be reproduced or duplicated in any form or by any means without permission Although we make utmost efforts this manual may not completely follow the revisions of the software and hardware In principle this software should be purchased by one set per personal computer or by license purchase This product including this manual can only be used under the software license agreement Please note that we are not responsible for any influence resulting from operating this product including this manual The contents of this manual are subject to chang
36. f the PRODUCTS are required For details please contact the Mitsubishi representative in your region A 2 REVISIONS The manual number is given on the bottom left of the back cover Print Date Manual Number Dec 2010 SH NA 080976ENG A First edition Appendix 5 Correction HOW TO USE THIS MANUAL Section 1 1 Section 3 5 section 3 5 4 Chapter 4 Appendix 2 Appendix 3 1 Appendix 3 2 Feb 2014 SH NA 080976ENG C Addition Appendix 6 Correction GENERIC TERMS ABBREVIATIONS AND TERMS Section 2 3 section 3 6 1 Appendix 2 i Section 3 3 1 Japanese Manual Version SH 080922 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2010 MITSUBISHI ELECTRIC CORPORATION INTRODUCTION Thank you for choosing the Mitsubishi MELSOFT series Integrated FA software Read this manual and make sure you understand the functions and performance of MELSOFT series thoroughly in advance to ensure correct use CONTENTS SA E Wd Pete RUINS sees cesses east entend ae teh een E E ihe simui utu afe A 1 CONDITIONS OF USE FOR THE PRODUC tetti etudiant dicho deu deo tein tee oes esaet A 2 REV ION or A 3 ATRODI TION or C LEER A 4 CONTENTS Tr x Pr r TA A 4 MANUA
37. g interval FF e Click the file selection button J To the next page 3 7 3 7 3 BASIC OPERATION From the previous page My Recent Documents File name PX TAG bt My Network Files of type Text File Cancel Melsec PX Developer Cancel Interval msec EER e Design D Documents and Settings Administrator My Documents JW_DataServer JDD File Setting window Help Dad SSO a IO im PX DRIVER PXTAG EB LOGICAL File Setting Window Help Ded SEO a 10 im PX DRIVER ff1 PX TAG amp LOGICAL 0 PROJECT 1 LICOO 1 MV PROJECT 1 LICOO 1 MV SINGLE 1 PROJECT 1 LICOO 1 PV PROJECT 1 LICOO 1 PV SINGLE 2 PROJECT 1 LICOO T SV PROJECT 1 LICOO 1 SV SINGLE PROJECT 1 LICOO 1 MV MELSOFT 9 The Open dialog box is displayed Select the defined file created in Section 3 3 1 and click the Open button 10 The selected file name is displayed on the device area setting dialog box Click the OK button 11 A device area is created under IO created driver PX DRIVER for this example in the tree Double click the created device area PX TAG for this example 12 A screen for setting device area tag name is displayed Check the tag registered in Section 3 3 1 is displayed Click File Use server from the menu Click File SaveAs from the menu 3 BAS
38. g on JoyWatcherSuite Setting a project in PX Developer Set PX Developer projects to be monitored on the monitor tool L Section 3 2 Setting basic settings and creating tags on JoyWatcherSuite Refer to process control tags when creating tags L Section 3 3 Developing monitor screens on JWEdit of JoyWatcherSuite To develop monitor screens use faceplate control of PX Developer L Section 3 4 Setting security manager alarm monitor on JoyWatcherSuite Set the security manager to read PX Developer alarms events to database Set to display data in the database on the alarm monitor L Section 3 5 Executing JoyWatcherSuite JWPanel Execute JWPanel the operating environment of JoyWatcherSuite while the PX Developer monitor tool is in operation gt Section 3 6 3 1 3 1 3 BASIC OPERATION MEL SOFT 3 2 Operation to Set PX Developer Projects to be Monitored on Monitor Tool t PURPOSE Register PX Developer projects containing defined process control tags to be monitored to the monitor target project setting This operation is to validate accesses from JoyWatcherSuite to process control tags to be monitored in the JoyWatcherSuite interaction function e Setting on PX Developer monitor Procedure 1 Set monitor target projects on the monitor tool L Section 3 2 1 3 2 1 Setting monitor target projects ES BASIC OPERATION B8 Monitor Tool Setting Monitor Target Project Se
39. h JoyWatcherSuite When an error message is displayed with the monitor tool by changing login users with JoyWatcherSuite log in with the GUEST mode which does not have the authority with JoyWatcherSuite once or log off and log in with the operation user again after the problem is solved APPENDIX MELSOFT Appendix 6 Functions Added to and Changed from Old Version The following table indicates the functions added and changed with the upgrade etl uds Added changed Description Reference version function Version 1 42U Supported OS Windows 8 is supported Section 2 3 1 The compatible version can be confirmed in Product Information For details refer to the PX Developer Operating Manual Programming Tool or Monitor Tool B 14 B 14 APPENDIX MELSOFT MEMO B 15 B 15 INDEX Al Alarm integration function 1 1 5 Alan MONO sone etna ete oa ie ade oat sda A 10 Assignment information database A 11 C Calling Monitor Tool Function from JoyWatcherSuite ssseeeeeeessss B 5 Communication function using process control tag NIST T T 1 1 3 Configuring database settings 3 21 Correspondence table for alarm items B 3 Correspondence table for event items B 4 Correspondence Table for Items of Monitor Tool and JoyWatcherSuite s B 3 D Data Types of Proces
40. he previous page 5 The Direct property is displayed Click the Select button Text Rd Right R Extend Definition Mode De C Hex Bin Exp C Hes C Hexa V Zerosupess comma WORD vy widh 8 o Bin char Eicm Cancel Apply Help Input Tag setting 6 The Input Tag setting dialog box is displayed LI Select the device area PX TAG for this cance Undo example created in Section 3 3 2 under PLC Tag in the tree m Click the tag registered in Section 3 3 1 from EBENE SIELEDUE SEE the tag selection list at the bottom center and double click the item to be displayed from the ie list at the bottom right The selected tag is displayed in the upper edit box Click the OK button LOCALSPX TAG PROJECT1 LICOO01 MVSVALUE i Name order Making order Refresh l To the next page When using the Input Tag setting dialog box start the server control 3 BASIC OPERATION MELSOFT From the previous page l Object property 7 The data set on the Input Tag setting dialog box are reflected on the Object property dialog box Click the OK button C Bin C Esp comma WORD Bin char t I5 of Cancel Apply 3 11 3 11 3 BASIC OPERATION MELSOFT 3 4 Operation to Use Faceplates of PX Developer in JoyWatcherSuite t PURPOSE Use faceplate control of PX Developer for developing process control mon
41. ing value of valve variable opening current HTCL MV CL Cooling manipulated CAN Setting value of valve variable opening target Setting value Sv LEM CC NP Monitor input blr DIM X Monitor input buffer B 1 B 1 App APPENDIX MELSOFT The following table shows the tag items which perform event notification Event notification tag Event notification tag MODE Mode BC PSUM PID 2PID NREV s RNR ALM TIMER1 TIMER2 CTNO Lookout tag No REV MVAL1 MVAL2 p PGS2 HTCL CTNO Lookout tag No COUNT1 COUNT2 Monitor input buffer Monitor input buffer MODE MODE e Lookout tag No 2PIDH SWM Monitor input buffer PFC SF PFC SS ALM2 ALM Alarm PFC_INT PVAL CTNO Lookout tag No ALM W1 Alarm 1 to 16 Monitor input buffer ALM W2 Alarm 171032 DM Monitor input buffer ALM 64PT ALM W2 Alarm 17 to 32 PIDP SPI IPD BPI R Mode ONF2 ONF3 MWM LAM ham SEL MOUT PGS Message m Tam Aam pamm cao ee RT cn roc M cct ir c m cd 1 This tag item consists of multiple BOOL type variables however it is displayed as a BOOL type variable on the MELSEC PX tag selection screen B 2 B 2 APPENDIX MELSOFT Appendix 3 Correspondence Table for Items of Monitor Tool and JoyWatcherSuite Appendix 3 1 Correspondence table for alarm items The following is a correspondence table for alarm items notified to JoyWatcherSuite by the monitor tool In the alarm monitor of JoyWatcher
42. inistrator My Documents Jw _Data Server JDD 3 24 3 24 3 BASIC OPERATION 3 5 3 Setting security manager ES BASIC OPERATION Security manager Database User Password Notification delay JoyWatcher Suite MELSEC Px ALARM MELSEC PX Event Log Log table P ALARM m M Delete Log Log Inc Tag Server ID Conversion file D Documents and Settings 4ll Users Documents JTE JoyWatcher P_ASLARMDIC tet Auto ack LOCALSSHARED PXWORD SVALUE Loo Clear all amp LOCAL WWORDO SHARED PX WORD1 Paste PX TAG Name order E Making order Security manager Database User Password Notification delay 0 a JoyWatcher Suite MELSEC PX ALARM MELSEC PX Event Log Log table PALALARM s Delete Log 0 LOCAL SHARED_PX WORDO VALUE Log Inc Tag Server ID 1 Conversion file D Documents and Settings All Users Documents JTE Joy watcher P _ASLSRMDIC txt Auto ack l To the next page 3 25 MELSOFT Click All Programs JoyWatcher Execution SecurityManager from the start menu to start the security manager Right click the security manager icon Kj in the task tray and click setUp from the menu The Security manager screen is displayed e Select from the database list box e Input a user name for a con
43. ions fH MELSEC a MM OMRON c NE OKOGANA m KE JT Engineering a F Database HF OPC BE Virtual PLC Common memory JTEMEMDR a g Advantech x HE FUJI_ electric c Hm HITACHI Ij JTEKT uw Ij KEYENCE x MEWTOCOL v Common memory Device SHARED Common memory J To the next page 3 22 MELSOFT 1 Click All Programs JoyWatcher Basic Setting JWDesign from the start menu to start the server design 2 The JWDesign screen is displayed Right click IO in the tree and click New from the menu 3 The Drivers dialog box is displayed Select JT Engineering Virtual PLC Common memory and click the OK button 4 The Common memory Device dialog box is displayed Input a connection name and note and click the OK button 3 22 3 BASIC OPERATION From the previous page l FL Design D Documents and Settings Administrator My Documents JW_Data Server JDD File Setting Window Help Dai RBIT ia 10 c PX DRIVER Set connect condition Rename F2 Delete Del New Logical table New Folder Create a new IO area D Documents and Settings Administrator My Documents JW_Data Server JDD Common memory Device Setting Cancel Mote Common memory WORD Device DWORD Device FLOAT Device DOUBLE Device BIT Device CHAR U 4 Byte LORD LONG e Design D Documents and Settings Administrator My Documents JW_Data Server JDD File Set
44. it from the start menu to start JWEdit 2 The JoyWEdit screen is displayed Click the Text button A 3 Place the text object on the process view and double click it BH 000000 1 False Object property sd Text fe Direct R Condition d Fill patterns E Line patterns R Position xd View mode s Fill E Click Dbl Click Drag Event File Event User Write to Enable ERE R Extend Definition Des Zero reset sec o Title Exp Caption Exp Write Ack Title Caption E 4 The Object property dialog box is displayed Click Mouse Left in the tree e Check the Enable check box and the Event check box under Event Click the setting button under Event DK Cancel Apply Help l To the next page 3 15 3 15 3 BASIC OPERATION MELSOFT From the previous page l Click action 5 The Click action dialog box is displayed FAMonitor FAMonitor Event Setting Click the to Suite button Show File New Window Modal Dialog Prev File Next File Go home Show Alarm Hide Alarm Toggle Alarm Open IE Print Screen Exec Program Exit ime cmn 6 The Suite dialog box is displayed Suit aM Click the MELSEC FP button TIE e Set the PX Developer process controller tag wincow Na current wn name in the edit box at the bottom ies 25 Click the Finish bu
45. items in the monitor tool 2 Troubleshooting related to the incorporation function of faceplate 4 1 control For troubleshooting for failures possibly occur in relation to the incorporation function of faceplate control refer to Error list in ActiveX control section of PX Developer Operating Manual Monitor Tool 4 1 4 TROUBLESHOOTING MELSOFT 3 Troubleshooting related to the alarm integration function This section explains troubleshooting for failures possibly occur in relation to the alarm integration function Trouble Cause corrective action Reference The monitor tool may not be executed or JoyWatcherSuite may not be set correctly Check the following items e Start the monitor tool in advance e Check the external database settings in the JoyWatcherSuite server monitor tool are not displayed Section 3 5 design l Section 3 6 Alarms or events of the on the alarm monitor of e Check if a tag used for Log Inc Tag is registered to common memory in the JoyWatcherSuite server design e The Log Inc Tag settings are different between JoyWatcherSuite server design security manager and alarm monitor e Check the settings of JoyWatcherSuite security manager JoyWatcherSuite 4 Troubleshooting related to JW Edit The event operation set on the object cannot be executed on the preview screen of JW Edit Therefore when executing operation check of event such as MELSEC FP and ExternalPr
46. itor screens on JoyWatcherSuite to reduce development time e Setting on JoyWatcherSuite Procedure 1 Paste a faceplate control and configure its setting lt gt Section 3 4 1 Procedure 2 Set showing faceplate from the object gt Section 3 4 2 e Execution on JoyWatcherSuite By executing JWPanel after starting the monitor tool faceplates can be used process control data can be monitored and process control parameters can be tuned for n pue mmm an LIC112 pe IEN 73 1 mia ry Reaction can liq g o I Egi E pm m Zimna Lydd EA t I ES Steam ome mh Lm I io Cold Wakr 3 a E gt lt a alii as F1 te p Fes wj mara m 1 HP lt Example of JoyWatcherSuite operating environment screen gt 3 12 3 12 3 BASIC OPERATION 3 4 1 Pasting setting faceplate control BASIC OPERATION FY JoyWEdit JoyWatch1 File Edit view Object Format Debug Window Help Dc el 2C amp gt DM SI COLIN RESI n WE NR 96 os Ga TA amp ZA BN pam n v gt X 0371 0004 Step 00000 Scale 100 8 JoyWEdit JoyWatch1 File Edit View Object Format Debug Window Help Dl LOR a2 SR r ew RIG AUN OO 47 m S OSG lai A DAs Ch Th AS Sh A 5 2 MEFR B JoyWatchi Object property MELSEC F R size EXP PX TAG R Extend Definition LICOO1 B Cancel Apply Help MELSOFT 1 Click A
47. ix 4 Calling Monitor Tool Function from JoyWatcherSuite A buzzer of monitor tool can be stopped or specified screen can be displayed by calling the MonCtrl command MonCtrl exe of the monitor tool from JoyWatcherSuite The following shows a setting method on JWEdit BASIC OPERATION 1 Double click the object pasted on JWEdit Object property 2 The Object property dialog box is displayed a ad e Click Mouse Left in the tree ondition v Enable Enable n inn mmm Check the Enable check box and check the E ine patterns M 2 ug eren EL E Event check box under Event PME 2 Set ExternalProgram for Event e Set MonCtrl exe for User Even ExternalProgram User DAMELSEC F bdq MonCtr exe buzze Click the OK button Write to re cit Definition Enable Exp Num Text Exps 3 sel Zero reset sec o Write Ack Title Exp Caption Exp Title MB Caption OK Cancel Apply Help 1 For functions that can be specified by the MonCtrl command refer to External Control of the Monitor Tool in PX Developer Operating Manual Monitor Tool APPENDIX MELSOFT Appendix 5 Security of Monitor Tool and JoyWatcherSuite The mixture of the user authority function of the monitor tool and the security function of JoyWatcherSuite enables to set the restrictions for operation of process control tag on the graphic screen and alarm chec
48. k of JoyWatcherSuite For details of the security function of JoyWatcherSuite refer to JoyWatcherSuite user s guide Appendix 5 1 Operating environment for using security of monitor tool and JoyWatcherSuite The following describes the operating environment for using security of the monitor tool and JoyWatcherSuite Application PX Developer Version 1 31H or later JoyWatcherSuite Version 6 1 or later Appendix 5 2 Setting procedure for using security of monitor tool and JoyWatcherSuite The following diagram describes the setting procedure for using the user authority function in the monitor tool and the security function in JoyWatcherSuite Start to set the items 1 Set the user authority function in the monitor tool 2 Set the security function in JoyWatcherSuite 3 Set to change the users of the monitor tool with JoyWatcherSuite Completed APPENDIX 1 Setting user authority function in monitor tool Set the following items in the monitor tool MELSOFT For details refer to PX Developer Operating Manual Monitor Tool 1 User Authority Setting ia Monitor Tool Setting User Authority Setting File Edit Debug User Authority Setting User Setting Monitor Target Project Setting OPS Setting Monitor Variable Setting Control Panel Setting Trend Setting Alarm Setting Event Setting User created Screen Setting Unit Setting Faceplate Display Pattern Setting Faceplate Display Scale Setti
49. ker Ee Mouse Bg Left Rd Right Rd Extend Definition 3 Alarm Monitor Fu Mouse 4 Tooltips m d Click effect Security amp Log Iv Enable No Dialog v Auth ID o gt Title Caption Equipment C Li i ooo NONE ___ Valid security and set the authority T Logging write I Logging Action ID required for the operations Cancel Apply Help Check the check box to valid the authority check of alarm monitor to control the check operation of MELSEC PX ALARM MELSEC PX Event Example Security when checking the check box to valid the authority check of MELSEC PX ALARM Set to operate the MELSEC PX ALARM check only for the role ID users who have authority ID 1 The following is the setting description e Setting description under Config Config Config Database Database Mx elect Database select data type SOL Color I Column Com Preview SaveToCSV C ALARM LOG JWServer C EV LOG Old Eventmanger Event Summery MELSEC PX Alarm C User DB C Scheduler JWScheduler C MELSEC PX Event C Security Log Etc Show Line no Color Print Auto refresh JoyVatcher Alarm V Tag value change LOCALSSHARED PXOWORDSVALUE Auto popup Requery when ack No Dialog No Dialog No Dialog B 12 Only the role ID users who have authority ID 1 can execute the check ope
50. ll Programs JoyWatcher Editor JWEdit from the start menu to start JWEdit 2 The JoyWEdit screen is displayed Click the MELSEC FP button il 3 Place the faceplate object on the process view and double click it 4 The object property dialog box is displayed Click MELSEC FP in the tree and set the PX Developer process control tag in the PX TAG column Click the OK button 3 BASIC OPERATION MELSOFT When the same process control tag name exists in different projects specify the tag as project name process control tag name If the tag is not specified in such format the process tag in a project with a high priority becomes an access target Faceplate control can be used on a personal computer in which PX Developer is installed and the monitor tool is being started 3 BASIC OPERATION MELSOFT 3 4 2 Setting of showing faceplate from object FY JoyWEdit JoyWatch1 Edit view Object Format Debug Window Help D c td a amp J 25 RGR noc Z eG S Glam fl SLA BINE JoyWatch1 Height For Help press F1 FY JoyWEdit JoyWatch1 File Edit View Object Format Debug Window Help Dk XB a 20 8 r 7M DUNN TAAT GS SG Sf DAs Dph AS ZA A x E S LA EHE JoyWatchi PosSize Left Top Width Height Line Color Style Width Pipe For Help press F1 BASIC OPERATION 1 Click All Programs JoyWatcher Editor JWEd
51. ment Reaction can liquid surface control Storage tank liquid surface control Storage tank liquid surface control Material B Reaction can liquid surface control Material B Material B Reaction can liquid surface control Reaction can liquid surface control Material 4 flow rate Material B flow rate Reaction can liquid surface control Material B flow rate kA baril A Alarm Contens Status Recovered Occurring Recovered Occurring Recovered Recovered Recovered Recovered Recovered Recovered Recovered Recovered Recovered Recovered Recovered Recovered Recovered Recovered Occurrence Date Recovered Date Level Confirm 12 07 16 40 23 12 07 16 40 20 12 07 16 40 09 12 07 16 40 06 12 07 16 39 59 12 07 16 33 58 12 07 16 39 55 12 07 16 39 55 12 07 16 39 54 12 07 16 39 39 12 07 16 39 23 12 07 16 39 21 12 0 16 39 19 12 07 16 39 11 12 07 16 33 03 12 07 16 38 58 12 07 16 38 57 12 07 16 38 50 12 07 10 90 A 12 07 16 40 24 12 07 16 40 11 12 07 16 40 02 12 07 16 40 01 12 07 16 39 58 12 07 16 39 59 12 07 16 40 00 12 07 16 40 01 12 07 16 39 24 12 07 16 39 26 12 07 16 39 25 12 07 16 39 25 12 07 16 39 14 12 07 16 40 02 12 07 16 39 26 12 07 16 38 51 1207 10 90 64 Minor 100 0 Minor 80 4 Minor 100 0 Minor 81 0 Minor 100 0 Minor 0 0 Minor 0 0 Minor 100 0 Minor 100 0 Minor 80 6 Minor 0 0 Minor 100 0 Minor 0 0 Minor 90 0 Minor 80 0 Minor 81 3 Minor 80 7 Minor 100 0 bd
52. nection and if a password is required input a password Seta table to store the PX Developer alarm information in the lt lt MELSEC PX ALARM tab Input a table name for Log table and click the Create button Seta tag to notify alarm changes to the alarm monitor Click the Log Inc Tag button The Tag select dialog box is displayed Select the common memory device created in Section 3 5 2 in the tree SHARED PX for this example Click WWORDO in the tag selection list displayed in the center and double click VALUE from the list on the right The selected tag name is displayed in the above edit box Click the OK button The settings in the Tag select dialog box are reflected on the Log Inc Tag edit box 3 25 3 BASIC OPERATION Security manager From the previous page Database User Password Notification delay JoyWatcher Suite MELSEC P ALARM MELSEC PX Event Log Log table Log Inc Tag Server ID Conversion file Auto ack Tag select FX EVENT 7 D Documents and Settings 4ll Users Documents JTEWJoyWatcher Px_EVENTDIC tet LOCALSSHARED_PX WORD1 VALUE Clear all LOCAL SHARED PX PX TAG WORDO CUT NENNEN UNIT 1 CMT DEADSEC RSTALM ALMLVL ENALM HIHI HI LO Name order LOLO CRATE Making order PA n nm Security manager Database User
53. ner function Notification IN Alarm event interaction function Process control Security manager 2 f tag data Data DDE communication DDE Data management interface 1 interface management Data communication other than process control tags Data communication M l Communication driver 1 JoyWatcherSuite reads writes process control tag data in the PX Developer monitor tool through DDE interface 2 The security manager is an application that stores information on alarms and events to the alarm database of JoyWatcherSuite Data communication 2 3 2 3 2 SYSTEM CONFIGURATION MELSOFT 2 3 Operating Environment PX Developer Version 1 28E or later and JoyWatcherSuite Version 6 0 or later are required for interacting themselves For the operating environment of PX Developer refer to Operating Environment in PX Developer Operating Manual Monitor Tool For the operating environment of JoyWatcherSuite refer to Start Guide of JoyWatcherSuite The following are the applicable system software operating system to operate this interaction function Microsoft Windows 2000 Operating system Microsoft Windows XP Home Edition Operating system Microsoft Windows XP Professional Operating system Windows Vista Windows 7 Windows 8 3 BASIC OPERATION MELSOFT 3 BASIC OPERATION 3 1 Operating Procedures for Monitoring on JoyWatcherSuite This section explains procedures for monitorin
54. ng Faceplate MY Characters Setting Lockout Tag Setting Option Setting Sancel Restore default Operatori _ Classification of operations Stop buzzer Print screen Exit monitor tool Change of the values of tag data item Process instruction values Mode Alarm threshold values Tuning parameter values Process design values Trend graph Export to CSV file Pop up tuning Export to CSV file Tuning trend collecting instruction Alarm Event Export to CSV file Print Confirm Delete PLC communication status Reset Setting Removing lockout tag Operatori Level E Operator Level L L riLd qo A A mons Operator3 Level Operator4 Level Engineer Level 2 User Setting ia Monitor Tool Setting User Setting File Edit Debug User Authority Setting B 7 User Setting Monitor Target Project Setting OPS Setting Monitor Variable Setting Control Panel Setting Event Setting User created Screen Setting Unit Setting Faceplate Display Pattern Setting Faceplate Display Scale Setting Faceplate MV Characters Setting Lockout Tag Setting Option Setting User 4 User 3 User 2 Usert 1 miim im iy m Is fs JE JI JE JE SN NNN NIN IN Operator2 mmu d Ny NIN qp IH gd Apply Cancel Password Operatori Set the operation restrictions for each user authority I LA m WV VY Y 1999 JLE aicina Ope rato r4 JE aliaa aaa aa aa Yd aa aa 1949 max qq Q4 ARAR VN
55. ogram check with JW Panel 4 2 4 2 APPENDIX MELSOFT APPENDIX Appendix 1 Data Types of Process Control Tag Items For lists of tag items of process control tag that can be selected on MELSEC PX tag selection refer to List of Various Tag Type Tag Data in PX Developer Programming Manual The following table shows the data types in JoyWatcherSuite corresponding to the data types of process control tag item in PX Developer Data type in PX Developer Data type in JoyWatcherSuite BOOL BIT a ee SHORT DINT LONG WORD USHORT REAL SINGLE Appendix 2 Main Tag Items Main tag items of process control tag displayed on the MELSEC PX tag selection are the tag items which perform the current value collection and event notification The following table shows the tag items which perform current value collection PID 2PID PIDP SPI IPD BPI R ONF2 ONF3 SEL mie edi em on E Setting value ael Y MV Manipulated variable SV Setngvalue NREV REV 5 MVAL1 MVAL2 PB T Tmeintestep TIMERI Monitor input buffer PV Process variable TIMER2 Setting value TYP Operation type COUNT Setting value ol Start a current COUNT2 Monitor input buffer MOUT MV Manipulated variable variable ALM ALM_64PT E corresponding current value MONI PV Process variable variable Process variable MSG MSG 64PT collection tags tee Motor valve opening Heating manipulated MV_HT Sett
56. or PX Developer process control tag names Alarm integration function i u CU The following are the development environment and operating environment of JoyWatcherSuite described in this manual Development environment JWDesign JWEdit Alarm Monitor MELSEC PX Tag Select Security Manager JWUserDef Operating environment JWPanel JWLauncher Security Manager 1 1 1 1 1 OVERVIEW MELSOFT 1 2 Features This section explains the main features of the four interaction functions 1 Faceplate control reduces development time of monitor screens By simply pasting faceplate control of PX Developer ActiveX control on JWEdit faceplates can be easily used on monitor screens of JoyWatcherSuite This reduces development time of monitor screens and tuning screens for process control tag data on JoyWatcherSuite Image of incorporating faceplate control PX Developer faceplate control TAGO001 JoyWatcherSuite PX Developer operating environment Reading writing process control tag data CE o 01 Compane Geous3 Compan Groups Compane Gross Corrgane Groups Compane Grow a gt Polling process control tag data Faceplates can be used by simply pasting ActiveX control on JWEdit 1 2 1 2 1 OVERVIEW MELSOFT 2 Without considering assigned devices communications can be performed using process control tag names in JoyWatcherSuite When registering tags in Joy
57. ple Security when writing numerical values to TICOO1 PH which is PV high limit alarm value of process control tag TICOO1 Since the operation classification of process control tag TICOO01 PH is alarm threshold value only role ID users which have authority ID 9 can execute the operations The following diagram describes the setting procedure 1 Double click the object for writing numerical value or right click the context menu and select Property 2 Click Mouse Left Button of left tree and set the numerical value writing to process control tag TICOO1 PH on Write to Object property Si Tex ie Left Valid the left button operation md Direct ud Condition ud Fill patterns i Line patterns Click Dbl Click ow Sd Position E pa moc Event E File LSS Sasa ET Rotation d Size Event ES Text color Event p Marker Tem E Mouse Left R Extend Definition V Enable Exp Num To _Eps 3 Des ALSPADDENAME Praoject TICOO1 PHSVALUE Title PX high limit alarm value MIN MAX Execute the setting to write the numerical value to TICOO1 PH APPENDIX MELSOFT 3 Click Mouse of left tree select Security amp Log and set the operation authority ID to process control tag TICOO1 PH Object property c Ege Text Bg Direct R Condition Ri Fill patterns R Line patterns E Position Rd view mode Eg Fill g Rotation Size R Text color R Mar
58. r N NZ MELSOFT Alarm Monitor of JoyWatcherSuite receives event notifications from the monitor tool and displays them For the correspondence table of alarm items notified by the monitor tool to JoyWatcherSuite refer to Appendix 3 1 3 19 3 BASIC OPERATION MELSOFT 2 Operating event monitor screen The following is an alarm monitor screen of JoyWatcherSuite px event jgr AlarmMonitor File Config Help oH 2 m us rem nid EE i Reaction can liquid surface control 12 07 15 36 08 AUT Reaction can liquid surface control 12 07 16 36 07 MAN Material B flow rate 12 07 16 36 03 AUT Material B flow rate 12 07 16 36 02 MAN Material 4 flow rate 12 07 16 35 58 AUT Material 4 flow rate 12 07 16 35 56 MAN 12 07 16 35 52 AUT 12 07 16 35 51 MAN 12 07 16 35 47 AUT 12 07 16 35 45 MAN Monitor Target Project was loaded 127207 16 33 13 Monitor Tool was started 12 07 16 33 09 Monitor Tool was stopped 12 07 16 32 26 Material B flow rate 12 07 16 31 02 AUT Material B flow rate 12 07 16 31 00 MAN Material flow rate 12 07 16 30 56 AUT Material flow rate 12 07 16 30 54 MAN 12 07 16 26 04 AUT 19 INF 1C 9C 01 KAAM lt Example of alarm monitor screen of JoyWatcherSuite gt JoyWatcherSuite receives event notifications from the monitor tool and displays them For the correspondence table of event items notified by the monitor tool to JoyWatcherSuite refer to Appendix 3 2 3 20 3 20 3 BASIC OPERAT
59. ration B 12 APPENDIX MELSOFT 3 Setting to change users of monitor tool with JoyWatcherSuite 1 JWPanel For changing the users of the monitor tool with JoyWatcherSuite check the check box of MELSEC PX User on the security setting of JWPanel This enables to change the modes of the monitor tool automatically when logging in JoyWatcherSuite or switching users Note that the mode to be changed in the monitor tool in this regard is changed to a mode of user who has the same user name and password entered when logging in JoyWatcherSuite or switching users is the same When logging in or logging off with the GUEST mode in JoyWatcherSuite the mode in the monitor tool is changed to the lock mode e Setting description under Security Setting Security Password LOGIN Title Auto lagoffiminute GUEST mode Auth ID D DLE oe gt m Check the check box of MELSEC Comment PX User to change the modes of the monitor tool when logging in or switching users Appendix 5 3 Procedure for monitoring operation with security interaction between monitor tool and JoyWatcherSuite When monitoring with security interaction between the monitor tool and JoyWatcherSuite monitor by following the procedure described below 1 Start the monitor tool and JoyWatcherSuite server with JoyWatcherSuite JW Launcher 2 Start JoyWatcherSuite JWPanel 3 Switch the users wit
60. s Control Tag Items S B 1 B Boqe c tac ets ened nase oaew ees A 10 BP gt M A 10 F gie jrt e TS A 11 EB RA A E A E NEU A 10 FB Der sequietaae A 10 I Incorporating faceplate control 1 1 2 J JoyWatcherSuite ccccccsssssseeeeeceeeeeeeeeees A 10 JIN DESIGN s ecd ho scaud s bauta edo neq sbalened A 10 3 6 22 dude HQ A 10 JuV E aunctier uu athlete A 10 JW PANGI seuer eee ee ere eee A 10 M Main Tag It MS ccccccsssesseeeeeseeseeeeeeeeees B 1 MELSEC PX Tag Select A 10 Monitor tool eeeeeeeeeeseeeeeeeee A 10 VIREMENT ERU ARE AA E A 11 O Operating alarm monitor screen 3 19 Operating event monitor screen 3 20 Operating Environment 2 4 Operating Procedures for Monitoring on JoyWatcherSuite eeeeusssssse 3 1 Operation to Communicate using Process Control Tag Names of PX Developer in JoyWatcherSuite Operation to Display PX Developer Alarm Event Information on Alarm Monitor of JoyWatcherSuite OCDE PECES 3 18 Operation to Perform Interactive Start Stop of PX Developer Monitor Tool on JoyWatcherSuite mem Ts 3 32 Operation to Set PX Developer Projects to be Monitored on Monitor Tool 3 2 Operation to Use Faceplates of PX
61. tain all alarms events from the monitor tool Server ID edit box at the security manager start and alarms events which are not notified to the Conversion file security manager are also stored to the database li When a file name is not specified only alarms events which occurred during the security manager start are stored to the database Check this to confirm PX Developer side alarms events at the moment when 8 6 T Auto ack checkbox data are stored to the database of JoyWatcherSuite The alarm event row is not displayed in the monitor tool bar 1 Set tables with a different name for alarms and events 2 Set the same tag with the JoyWatcher Tag Change tag of the alarm monitor auto update setting 9 Set tags with a different name for alarms and events 4 Set files with a different name for alarms and events 3 27 3 27 3 BASIC OPERATION MELSOFT For operations of alarms events it is recommended that the Auto ack check box is checked and Alarm Monitor of JoyWatcherSuite is used For alarms whose occurrence status is information alarms whose recovery date is not displayed the automatic confirmation is not performed to prevent frequent alarm occurrence even when the Auto ack check box is checked When an alarm whose occurrence status is information is occurred check the alarm on the alarm screen of the monitor tool after fixing the problem that caused the alarm 3 28 3 28 3 BAS
62. tegration check Main Po boxes under Cooperation with MELSEC PX 2 I __ k Input a value for Start Wait Time Cooperation With MELSECPX Click the OK button v Start v Endlntegration StartyvaitTimedmin To Section 3 6 2 To perform interactive stop of the monitor tool the mode of the monitor tool needs to be changed to the engineer mode For changing the mode to the engineering mode when starting the monitor tool refer to Monitor Tool Startup Option in PX Developer Version 1 Operating Manual Monitor Tool e The monitor tool cannot perform interactive stop when any dialog box is being displayed End the monitor tool manually e f the monitor tool is restarted while JoyWatcherSuite and the monitor tool are in an interact operation JoyWatcherSuite must be restarted as well When the start time of the monitor tool becomes longer because of the large number of monitor target projects adjust the Start Wait Time e When Endlntegration of the MELSEC PX interaction setting is enabled on JWLauncher do not register JWLauncher to user graphic of the monitor tool 3 33 3 33 3 BASIC OPERATION MELSOFT 3 6 2 Setting interactive start stop of security manager NONAME Joy Watcher Suite Launcher BASIC OPERATION sr Task State StartPattern NextRunTime JoyWatcher Suite Launcher startProgram LastRunTime MultiFaMonitor StartingAssociated O JWPanel Schedule Manager O
63. the alarm monitor of JoyWatcherSuite 1 5 1 5 2 SYSTEM CONFIGURATION MELSOFT 2 SYSTEM CONFIGURATION 2 1 System Configuration This section explains system configuration when using the interaction function of PX Developer and JoyWatcherSuite For communication routes supported by PX Developer refer to SYSTEM CONFIGURATION in PX Developer Operating Manual Monitor Tool To use the interaction function install PX Developer and JoyWatcherSuite to the same personal computer If they are installed to different personal computers the interaction function cannot be used System configuration image English version of JoyWatcherSuite English version of Version 6 0 or later PX Developer Version 1 28E or later Use a communication driver depending on the situation 1 Communication route supported by the PX Developer monitor tool pu II ES LLLLELETT PLL LL A a 1 For reading writing device data other than process control tags in JoyWatcherSuite a communication driver is required 2 SYSTEM CONFIGURATION Point The following tables show the validation invalidation of the interaction function according to the combination of monitor tool and JoyWatcherSuite MELSOFT Monitor tool Not installed JoyWatcherSuite Reference function for PX Developer Le process control caiman RN name Faceplate control Faceplate control display Communication function using process
64. ting Window Help Dad SEO a IO Hig PX DRIVER fy PX TAG im SHARED ER LOGICAL D Documents and Settings Administrator My Documents Jw DatalServer JDD l To the next page 3 23 MELSOFT A common memory is created under IO in the tree Right click the created common memory SHARED for this example and click New from the menu The Common memory Device Setting dialog box is displayed Input a connection name and note e Input 2 for WORD Device Click the OK Button A common memory device is created under IO created common memory SHARED for this example Select the created common memory device SHARED PX for this example and double Click it 3 23 3 BASIC OPERATION MELSOFT From the previous page l E Design D Documents and Settings Administrator My Documents JW_Data Server JDD 8E V 8 A screen for setting device area tag name is O New Ctri N 5m Open Ctr oO displayed Gel save Ctr E SP SHARED PX Save s 5 T NUM E me Click File SaveAs in the menu SHORT Recent fle ED PX 1 WORD WORD SHORT The created common memory device is used for the security manager setting in Section 3 5 3 and the alarm monitor setting in Section 3 5 4 Write EXCEL Read EXCEL Standard Numerical alarm Engineering conversion Security TAG WORDO Unit Notes D ipocuments and Settings Adm
65. trol tags to be monitored on JWEdit L Section 3 3 3 e Execution on JoyWatcherSuite The process control tag data can be read written by executing JWPanel after starting the monitor tool quim nimimm r3 LINE t J 4 Makia E T B uar 423m am mn a gj n ir um EE Fr 3 jm iis E Em PER PETS TS ul 5 E E Liquid HLS m E E mm z Wet 4 E i i i vn P B i m CL E Le Be DSL IET Coad watr E T cs i es lt Example of JoyWatcherSuite operating environment screen gt 3 3 3 3 3 BASIC OPERATION 3 3 1 Registering process control tags Zi MELSEC PX Tag Select File F Edit E Help H ES BASIC OPERATION PROJECTI Licoot AUT CAS CMY CSV CTNO DIM AT ID DIM AT MODE DIM AT MVH DIM AT MVL 7 MELSEC PX Tag Select File F Edit E Help H Dau tee eo Main All gt My T PROJECT1 L2 SINGLE PROJECT1_L PROJECT1 L 2 SINGLE PROJECT1_L T PROJECT1 L 2 SINGLE PROJECT L My Network File name Places Save as type PX_TAG txt m Text txt Y MELSOFT Click All Programs JoyWatcher Basic Setting Connection Tools MELSEC PX from the start menu to start MELSEC PX Tag Select The MELSEC PX Tag Select screen is displayed A list of process control tags of PX Developer registered on the monitor tool is
66. tting File Edit Debug User Authority Setting Apply Cane User Setting Monitor Target Project Setting Project Name Assignment Information Database File PLC Type Transfer Setup OPS Setting Q12PH USB Monitor Variable Setting Control Panel Setting User created Screen Setting Unit Setting Faceplate Display Pattern Setting Faceplate Display Scale Setting Faceplate MV Characters Setting Lockout Tag Setting Option Setting Duplicated Tag Name Duplicated Project Name On the monitor tool register the PX Developer project containing defined process control tags to be monitored to the monitor target project setting For registering projects refer to Monitor Target Project Setting in PX Developer Operating Manual Monitor Tool To validate the set data close the monitor tool setting screen or click File Save the setting data from the menu 3 2 3 2 3 BASIC OPERATION MELSOFT 3 3 Operation to Communicate using PX Developer Process Control Tag Names in JoyWatcherSuite i PURPOSE Register tags using process control tag names defined in PX Developer and read write the process control tag data of the monitor tool in JoyWatcherSuite e Setting on JoyWatcherSuite Procedure 1 Register process control tags to be used for MELSEC PX Tag Select L Section 3 3 1 Procedure 2 Set the settings to communication with PX Developer by JWDesign L Section 3 3 2 Procedure 3 Set process con
67. tton Open IE Print Man Report Assistant MELSECFP Exit ShowMelsecFP To FaMonitor LICOO1 Finish Cancel Object property 7 The settings in the Suite dialog box are arg ur Ed Condos Z Enebe reflected on the Object property dialog box eese ow DBOkk Drag Click the OK button G Position Event File S jw Event Event ShowMelsecFP User LICOO1 Im fd Rig Write to f Extend Definition Enable Exp Num Text Exps 3 sel Des Zero reset sec jo a Write Ack Title Exp Caption Exp Title Caption M DK Cancel Apply Help 3 16 3 16 3 BASIC OPERATION MELSOFT When the same process control tag name exists in different projects specify the tag as project name process control tag name If the tag is not specified in such format the process tag in a project with a high priority becomes an access target e MELSEC FP can be used on a personal computer in which PX Developer is installed and the monitor tool is being started The operation of MELSEC FP displayed on the preview of JWEdit is invalidated Use JWPanel to check the operation 3 BASIC OPERATION MELSOFT 3 5 Operation to Display PX Developer Alarm Event Information on Alarm Monitor of JoyWatcherSuite PURPOSE Display and monitor alarms and events of the PX Developer monitor tool on Alarm Monitor of JoyWatcherSuite e Setting on JoyWatcherSuite Procedure 1 Configure the d
68. uite Abbreviation for JoyWatcherSuite Version 5 0 or later Generic term for Microsoft Windows 8 Operating System Windows 8 Microsoft Windows 8 Pro Operating System and Microsoft Windows 8 Enterprise Operating System Generic term for Microsoft Windows 7 Starter Operating System Microsoft Windows 7 Home Premium Operating System Windows 7 Microsoft Windows 7 Professional Operating System Microsoft Windows 7 Ultimate Operating System and Microsoft Windows 7 Enterprise Operating System Generic term for Microsoft Windows Vista Home Basic Operating System Microsoft Windows Vista Home Premium Operating System Windows Vista Microsoft Windows Vista Business Operating System Microsoft Windows Vista Ultimate Operating System and Microsoft Windows Vista Enterprise Operating System Personal computer Generic term for IBM PC AT compatible personal computer 2 Terms JWPanel Operating environment of JoyWatcherSuite Operating environment of JoyWatcherSuite w Windows standard communication protocol between applications as A control of controller functions with a digital device PX Developer DDE DDC FB Abbreviation for Function Block A block with a specific function used in a program Tags for identification attached to process control equipment Process control tag l Pe They are JIS defined identification symbols attached to DDC processings A 10 A
Download Pdf Manuals
Related Search
Related Contents
3-Aire paillée en creux avec couloir d`alimentation raclé en lisier.indd UTV-1100 Multi Gauge for 2007 Yamaha Rhino Honeywell T8501D User's Manual Australian Arrow Boards User Manual MINI-CAD - Index of 取扱説明書 RN-ONE-Benutzerhandbuch-09-2014 - Race 取扱説明書 - 山田照明 Page 1 Page 2 概要 ` 製品と付属品の確認 仕様 ~ 取り付け 安全上のご Creda W200FW User's Manual Copyright © All rights reserved.