Home

CP-300 (300x0.1g) - User Manual

image

Contents

1. key 2 Wait until 0 0 or 0 00 is displayed 3 Place the item s to be weighed on the platform 4 Using the MODE key you can switch between weighing units 5 To turn the scale off press the key again Il TARE WEIGHING To weigh using the tray you can place it on the platform before turning the scale on or 1 Turn on scale as described in the first section 2 Place the weighing tray or container on the platform 3 Press key briefly and wait until 0 0 is displayed 4 Add the net weight item to the tray or container Ill CALIBRATION Only calibrate your scale if your scale is not weighing properly This scale comes pre calibrated A CP 300 Calibration Steps 1 Turn off the scale Press and hold the MODE key then press the O key until the display shows a random number Now release both keys 2 Press the key again The display will show AL 0 then 300 0 Gently place a 300g weight on the center of the platform and press the key again The LCD will display AL F then 300 0 3 Calibration is complete If the scale shows AL E an error has occurred Turn off the scale and repeat steps 1 through 3 above A CP 300 Calibration Steps 1 Turn off the scale Press and hold the MODE key then press the key until the display shows a random number Now release both keys 2 Press the key again The display will show AL 0
2. AWS American Weigh Scales Inc CELLPHONE CP 300 300 x 0 1g CP 100 100 x 0 019 User Manual Cellphone Scale Manual Thank you for purchasing the American Weigh Cellphone Scale Please read all operating instructions carefully before use This electronic scale is a precision instrument With normal care and proper treatment it will provide years of reliable service Never load the scale with more than the maximum capacity Overloading will permanently damage it Avoid any exposure to extreme heat or cold Your scale works better when operated at normal room temperature Always allow the scale to acclimate to normal room temperature for at least one hour before use Give your scale sufficient warm up time Usually 30 60 seconds before calibration to give the internal components a chance to stabilize Keep your scale in a clean environment Dust dirt moisture vibration air currents and a close distance to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale Handle with care Gently apply all items to be weighed onto the platform Although this scale is designed to be quite durable try to avoid rough treatment as this may permanently damage the internal sensor Avoid shaking dropping or otherwise shocking the scale This is a precision instrument and must be handled with extreme care Only operate the scale on a stable vibration free surface OPERATION 1 Press
3. conditions Please keep this in mind and maintain and operate your scale properly This scale is a precise instrument and must be handled with the utmost care and caution Display Solution Nothing Change the batteries EEEEE You are overloading the scale Remove the excessive load immediately Oue2 The delicate weighing load cell has been damaged by misusing the scale i e it was shocked dropped or overloaded You can try recalibrating Specifications Model CP 300 CP 100 Capacity 300g 10 5850z 9 645ozt 100g 3 5280z 500ct 193dwt 1543gn Resolution 0 1g 0 0050z 0 005ozt 0 01g 0 0010z 0 05ct 0 1dwt 0 1gn Calibration Weight 300g sold seperate 100g sold seperate Scale Dimensions inches 2 2x46x1 Warranty 10 Year Warranty Power 2 x AAA Batteries included
4. then 100 00 Gently place a 100g weight on the center of the platform The LCD will display AL F then 100 00 3 Calibration is complete If the scale shows AL E an error has occurred Turn off the scale and repeat steps 1 through 3 IV CLOCK OPERATION 1 Diagram A Hour 12 24 Time _ B Mode Set Enter C Minute Start Stop D Backlight 2 Clock Mode amp Timer Mode a Press button B to switch between normal Clock Mode and Timer Mode 3 Setting the Clock a While in normal Clock Mode press and hold the B button b The clock s hour and minute digits will flash c Press button A to increment the hours by one Hold to go faster d Press button C to increment the minutes by one Hold to go faster e Press the B button when you are finished setting 4 Setting the Timer a While in Timer Mode X press and hold the B button b The timer s hour and minute digits will flash c Press button A to increment the hours by one Hold to go faster d Press button C to increment the minutes by one Hold to go faster e Press the B button when you are finished setting 5 Using the Timer a After setting the timer press the C button to start the countdown b Press the C button again to stop it V TROUBLESHOOTING The primary reasons for inaccuracy or malfunction are low batteries incorrect calibration overload or operating under unstable

Download Pdf Manuals

image

Related Search

Related Contents

Operating Instructions Manuel d`utilisation Instrucciones de operación  Canada - Buyandsell.gc.ca  Manual curto  User Manual - Janus Remote Communications  Great Day HU200B Instructions / Assembly  User Manual  1 入門ガイド 2 製品外観の説明 4 製品の標準装備と  「太陽の塔からのメッセージ 岡本太郎とEXPO`70」展 (PDF:417KB)  Mode d`emploi  F150-3 - Valtek  

Copyright © All rights reserved.
Failed to retrieve file