1. Flow Test Fixture Test Key Tool Vent Valve Hand Wrench Demand Port Wash Plug Regulator Wash Cover Combination Pick Tool 00 Phillips Head Screwdriver 1 Phillips Head Screwdriver 2 Phillips Head Screwdriver 1 8 Slotted Screwdriver 3 16 Slotted Screwdriver Hex Driver 3 16 Nut Driver 5 16 NutDriver 9 32 Nut Driver 3 8 x 5 16 Open End Wrench 5 8 x 9 16 Open End Wrench 7 16 Combination Wrench Combination Wrench Leak Tec Leak Detection Fluid 8 ounce Bottle Tool Storage Pouch 3 8 Outside Diameter Rubber Tubing 6 Feet Stopwatch AV3500 PRO Mask Leak Check Adapter Fitting 3 32 T Handle Hex Key User Manual Page 2 of 5 Part Number _ B6 02 5000 15 0 B6 02 5000 17 2 B2 03 3000 01 0 B2 06 6002 60 0 B2 02 5400 04 0 B2 03 1000 10 0 B2 03 1000 15 0 B2 03 1000 03 0 B2 03 1000 16 0 B2 03 1000 22 0 B2 03 1000 01 0 B2 03 1000 17 0 B2 03 1000 09 0 B2 03 1000 12 0 B2 03 1000 21 0 B2 03 1000 04 0 B2 03 1000 05 0 B2 03 1000 06 0 B2 03 1000 13 0 B5 01 3000 03 0 B2 02 7001 28 0 B4 02 6037 00 0 B2 03 1000 20 0 B6 02 5003 00 0 B2 03 1006 00 0 B5 06 6900 15 0 Quantity e P erre rererere NeN PPR rererere PRP PRO BPN B5 06 6900 15 0 A47D523 ECO 9953 April 2014 BIOPAK 240R Maintenance Tool Kit User Manual Revision A Tool Kit Part Number B6 02 5003 79 0 Various Tests That Can Be Performed With The Maintenance Tool Kit Note The following tests are
2. be leak tested as per the following procedure Connect an aspirator bulb to the input barb of the tool kit as depicted above Verify that the vent valve of the kit is CLOSED Slowly squeeze the aspirator bulb to achieve a pressure reading between 15 20 mbar on the tool kit pressure gauge One squeeze of the bulb is usually sufficient to achieve the pressure reading Do not over pressure the system Allow the aspirator bulb and the tool kit to sit undisturbed for a period of one minute Page 3 of 5 B5 06 6900 15 0 A47D523 ECO 9953 April 2014 BIOPAK 240R Maintenance Tool Kit User Manual Revision A Tool Kit Part Number B6 02 5003 79 0 4 The pressure gauge reading shall not change during the one minute period If the reading moves downward there is a leak in the tool kit or the aspirator bulb that must be found and corrected If the reading moves upward the aspirator bulb may have been disturbed or may been depressed again during the one minute period 5 Remove the aspirator bulb after successfully completing the test procedure There are no other field adjustments required of the Maintenance Tool Kit Page 4 of 5 B5 06 6900 15 0 A47D523 ECO 9953 April 2014 BIOPAK 240R Maintenance Tool Kit User Manual Revision A Tool Kit Part Number B6 02 5003 79 0 Original Manufacturer Information Biomarine Inc A Wholly Owned Subsidiary of Neutronics Inc 456 Creamery Way Exton PA 19341 U S A Phone 610 524 8800 F
3. only provided as an example of testing that can be conducted with the Maintenance Tool Kit Refer to The BioPak 240R Benchman Manual for full details of testing Constant Flow Test Provides testing of the constant oxygen flow rate into the breathing loop of the BioPak 240R Low Pressure Leak Test Provides gas tightness testing of the BioPak 240R breathing loop High Pressure Leak Test Provides gas tightness testing of the BioPak 240R oxygen cylinder connection pressure regulator high pressure gas lines and remote pressure gauge Vent Valve Relief Test Provides testing of breathing pressure required to open the breathing loop over pressure valve All other testing required for the BioPak 240R respirator DO NOT require tools of any kind Self Calibration of the Maintenance Tool Kit The Maintenance Tool Kit only requires field adjustment of the internal pressure gauge periodically Whenever the internal pressure gauge of the kit does not read zero 0 pressure with all ports fully open then adjustment is required as follows 1 2 3 4 Open the vent valve of the tool kit located on the top panel Verify that no tubing is connected to the vent port on the top panel of the tool kit Place the tool kit on a flat surface Use a screwdriver to adjust the ZERO screw located on the dial of the pressure gauge so that the gauge pointer aligns with the zero 0 pressure indication The Maintenance Tool Kit pressure gauge plumbing can
4. BIOP A lt iml a aii BIOPAK 240R MAINTENANCE TOOL KIT User Manual TOOL KIT PART NUMBER B6 02 5003 79 0 Revision A Contents Subject Page About the Maintenance Tool Kit 1 Description of the Maintenance Tool Kit 2 Various Test That Can Be Performed with the Maintenance Tool Kit 3 Self Calibration of the Maintenance Tool Kit 3 About the Maintenance Tool Kit The Maintenance Tool Kit B6 02 5003 79 0 provides the user with all test equipment and tools required to conduct original manufacturer specified maintenance as directed by the BioPak 240R Benchman Manual The kit is supplied in a rigid and water proof case to provide ease of transport and equipment protection The kit is supplied from the factory with an analog pressure gauge bleed control valves and all tools and equipment required to service the BioPak 240R respirator Page 1of5 B5 06 6900 15 0 A47D523 ECO 9953 April 2014 BIOPAK 240R Maintenance Tool Kit User Manual Revision A Description of the Maintenance Tool Kit The following are the details to describe the BioPak Maintenance Tool Kit Part Number Form Dimension of Tester Weight of the Tester B6 02 5002 16 3 Tool Kit Part Number B6 02 5003 79 0 Solid compact international orange or black color water tight air tight dust tight lockable lock not included plastic case 40 x 32 x 18 cm 5 5 kg The Maintenance Kit is supplied with the following tools and equipment Description
5. ax 610 524 8807 Web www BioPak240R com Page 50f5 B5 06 6900 15 0 A47D523 ECO 9953 April 2014

Download Pdf Manuals

image

Related Search

Related Contents

Arke K21003 Installation Guide  XiVE surgical manual - Dentsply International  Alert Eagle® 100 and 120 Decoders 07/21/15  république française  Válvula Globo - GEMÜ de válvulas  Operating Manual Manuel d`utilisation Manual de operación    Service Manual - Ottobockdoc.se  Utilisation de la Radio Garmin SL30  Detailed User Manual  