Home
        User Manual and Troubleshooting Guidelines
         Contents
1.                       SONVYO         0   SvvQOVO 3SGONO SGATINI OL JILL Q3SIA3M         30  14002 Y NI Q31S31NOO 38                                C3N30ISNOO         0   L11cQvO XJAWNN            00   9                        38 TIVHS            IVINGWNOBIAN3          YOTAVL        IN3SNOO         0                       OL dOWO WOMJ G3SIA3N    N3LLIMM                3178141510 MO AdOO OL ldWG3llV ANY          WIN3NNOBAN3 3QvW           30 AlN3dONd        SI IN3WND00                                 SIHL NIHLIM Q3NIVINOO NOLLVNSO3NI 3HL  310N                                 ejpun                 ueunis                                              sue                                                     5                SSFINN VO ZL        S3MIM          dOW  3Nvd                TWOINVHOSW                   HOLIMS                                    4 Q3ZlWviOd             JIN              q38   18  MOTI3A    9          aay    18 1HM                            TONO                  ASN S LI OL                     SIH L HO NOISIA3 AHL AdIH3A OL           JHL      ALFTISISNOdS3H        SI LI  AdOO GATIONLNOONN    A TINO 3ON3H333       ud Zio   10 320 2            VVOLOLOLW    21 ZH09   0S 2VAO   Z 61     dOW  1009 LH9IVMIS ILYN NIBVO    Z9 9   91   4WONO    WVYOVIC   NIXIM    9vvvec    IGENDN luvd    66 02 21   31VQ                   10855944    7          v9 91 034  VO 9  MOTISA    SONVYO          Jj               prev                 duis   puruJe      AGLL         LI     NAN Zl 
2.         12  Installation Checklist  review prior to installation                  13  OPERATION   Operations Checklist                              eese 13  Mechanical Control Panel  MCP  Operation                         14  Digital Control                   See Specific Digital Control Manual    MAINTENANCE TROUBLESHOOTING    Seawater System  Return Air Filters  Winterization              15  Trouble Shooting Appendix                                              16 21  Manufacturers Limited Warranty Agreement                        22  Dealers Distributors                                                        23 27    MARINE AIR SYSTEMS    Marine Air Systems  MAS  is a product of Dometic Environmental Corporation  Dometic is a recognized leader in the  design and manufacture of high performance comfort control systems  refrigeration products and battery charging  products for demanding environments  including commercial and recreational marine craft  vehicles and other applica   tions  We offer an unparalleled scope of products  dealer networks  applications support  engineering resources and  production capabilities throughout the world  Our team has many years of experience in the design  manufacture  applica   tion and support of our products  Our practical experience and design capability allows our application engineers and  sales representatives to offer optimum solutions for your environmental control requirements  Product lines also include  well known Cruisair  Gr
3.    AlddnSs                          30  1002 V NI Q31S31NOO 38                                C3N3dISNOO       38 TIWHS            IVIN3ANOSIAN3                                LNISNOD       10   6S80vO 1014 Ol SION             N3LIMM              3ln8RHISIQ NO   909 OL ldN3llV ANY           IVINGWNOMIAN3        NDTIAVL 30 AlMi3dONd        SI IN3Wn20         NOISIA3M                 NIHLIM                  NOILVAHONI JHL  310N                                       11    L 2271 Cabin Mate     ELECTRICAL CONNECTIONS  GROUNDING AND BONDING   amp  ABYC STANDARDS    All a c units have a terminal strip mounted either inside or outside the electric box  The terminal strip is labeled for proper  connections of the electrical supply  ground wires and pump circuits  A wiring diagram is provided in the electrical box and  in this manual  The wiring diagram in the electrical box supersedes the one in this manual  The correct size circuit breaker  should be used to protect the system as specified on the a c unit s data plate label  A minimum of 12 AWG boat cable  should be used to supply power to the a c unit and the seawater pump  All connections shall be made with ring or fork  terminals  Turn off a c power supply circuit breaker before opening electrical box     Each a c unit installed requires its own dedicated circuit breaker  If there is only one a c unit installed  the seawater pump  does not require a circuit breaker  the wiring from the seawater pump is connected to the terminal s
4.    Phone   586  778 8950   Fax   586  778 6108  Wyoming    American Marine Contractors  Location  Seattle  WA  USA  Phone   206  660 2240    Fax   206  548 5008  E mail  gene  nwmarineair com  Antigua    Austria    Caribbean Islands       Dometic Marine   Italy  Sales Company  Location  Milano  Italy  Phone  390 26172583    Fax  390 266010223  E mail  marine info   dometic it  Web  www dometic com  Bahamas          Freezing Point  Ltd   Location  Nassau  Bahamas  Territory  Nassau   Phone   242  325 3589    Fax   242  356 5271  E mail  rolandknowles   bahamas net bs    Bahrain       Mantech  Location  Dubai  United Arab Emirates    Phone   971  4 3332 542  Fax   971  4 3330 649    Brazil       Marine Express  Location  Sao Paulo  Brazil  Phone   55 11 5182 7166    Fax  55 11 5183 3636  E mail  fabrizio   marinexpress com br  Web  www marinexpress com br    British Virgin Islands       BVI Marine Management   Location  Roadtown  Tortola  British Virgin Islands  Phone   284  494 2938   Fax   284  494 5006   C  amp  G Refrigeration   Location    Tortola  British Virgin Islands   Phone   284  776 0038    Canada          Aboard Refrigeration   Location    Antigua  West Indies  Phone   268  460 1690   Fax   419  858 0544   E mail  aboardrf  candw ag   Web  www aboardrefrigeration com    Argentina       Baron SRL  Location  San Fernando  Buenos Aires  Argentina  Phone   54  11 4 580 5556    Fax   54  11 4 746 1696  E mail  rosito 9 baron com ar  Web  www baron com ar  Australia     
5.   Seairland Systems  Inc    Location  Brisbane  Queensland  Australia  Phone   61  7 3268 7511   Fax   61  7 3268 1445   E mail  hadyn  seairland com au    British Columbia    American Marine Contractors  Location  Seattle  WA  USA  Phone   206  660 2240    Fax   206  548 5008  E mail  gene Q nwmarineair com  Ontario    Northland Supply Company  Location  Queensville  Ontario  Canada  Territory  Queensville   Phone   905  478 2244    Fax   905  478 2295  E mail  norsupco    aol com  Web  www norsupco com    Woodard and Company   Manufacturer s Rep     Location  Concord  Ontario  Canada  Territory  All Canadian Provinces except BC  Phone    905 760 0245    Fax   905 760 0250   E mail  john reid   woodardcompany com  Quebec   Kimpex  Inc     Location  Drummondville  Quebec  Canada  Territory  Drummondville  Quebec  Phone   705  721 0947    Fax   705  721 1704  E mail  Scott pipher    kpx kimpex com  Web  http   www kpx kimpex com    Aboard Refrigeration  Location    Antigua  West Indies  Phone   268  460 1690    Fax   419  858 0544  E mail  aboardrf 9 candw ag  Web  www aboardrefrigeration com    BVI Marine Management  Location  Roadtown  Tortola  British Virgin Islands    Phone   284  494 2938  Fax   284  494 5006    C  amp  G Refrigeration  Location    Tortola  British Virgin Islands  Phone   284  776 0038    Caraibes Distribution  Location  Marin  Martinique  French West Indies    Phone   0596 257292  Fax  0596 747353    Centro Cruisair de Puerto Rico  Location  San Turce  P
6.   VO cL        SJAM                    suey                AZOLOLOLW    Wvasovia   1 2H09   0S 2VAO Z 611     Q310N  832   22 2    91 ZWOWO    ASIMYSHLO 5537131    V9             SSYIM        055                 dOW  TaNVd                   VOINVHO3N HOLIMS          55        HOIH                          NOSS3HdNOO  XO8 191419319                   91                        dyo            151559  Tavis  Mold    H  LIMS  Hz        AINO 591 01                                   M18 1HM            3   9frld  JVI    Q3Zlav 1Od  IN    ONnO39                            91  Ovid              O33   18  MOTI3A                aay    18 1HM          N3349        OI x0        00    AGLL AOS   L1 L1  NAN cl    AlddnSs                91  033 78    1  15 1  TANVd 1OMINOO 80      91          304 6SOOLOLW  S OMG                     X     N                MVI 40 140029 V NI GALSSLNOO 38                 10                            OL S39n VO JYIM        Q3SIA3H    vO SL 9       LO 6S80VO YO1ld 01 31ON               L0 6c 8                           83   NOISIA3H                                                           5    9      TIVHS NOIL VHOdNOO                      LN3SNOO            LNOHLIM  ALNGMLSIG HO AdOO OL Ld W3 L1V ANY  NOILVHOdNOO             30                  JHL SI LN3AIOOQ SIHL NIHLIM                     NOLLVWHONI         310N AYYLIIHdOYd                dvd    LO   9760V9   138V1_O1  3A3I  NOISIA3N QQV  10 6480  0 Hold Ol ALON                         NOISIA3H       ANI 30  
7.  14000       Q3IS3INOO 38 NVO        TNAMVINN Q3N30l5NOO  38 TNHS         IVIN3NNOSIAN3          3OTAVL NOYA INISNOJ  NALAM LOOHLIM 31n8IMISIQ HO   400 OL ldW3llV ANY           WIN3ANOMIAN3        NOTAVL 40                         SI IN3An20Q  SIHL                                                JHL  310                                L 2271 Cabin Mate                                            Jv                IeSI          SULe                                             ud 7GE0        unr      24701       TANVd AVIY                          5  35      3015100    LdO           5  35      LIV 140      TANVd AV1dSIG LYOdSSYd    91  OVI     AINO 391 01        HOLIMS 334nSS3Md  109 38 LSAW    01  9          N3HM  Sar    f N3dAnn  JON             VOlM1O3Tl3    Wed                                                              AB NMYHO      6110101       1 Z2H09 0GS 9VAO  Z  ll    81  N3349                     er             0 1 1MOdSSVvd   0002 JLVW              29 23 Z  4391 S509W2                     H3BWON                        SNIMIM     AINO SLNN  310A0 3SN3A33   7109 GION310S             9ONISS3A3M    HOLIMS  3anss3sud              81d MONJA                18 1HM    39nv9 81        418 LHM    39NVHO    Alddns                r            No                     8         21 3                                          a  NVJ 3NA dico          ding Avs anoo      LT       140455                 BION 335  992 9 8                      Oz4 owris Sanss    INO                   s r   
8.  BY  RMW PART NUMBER   O  WITHMAS ENGINEERING                             muet E M1020043    L 2271 Cabin Mate  6                               HOW IT WORKS    Your self contained air conditioner consists of four main components and a refrigerant gas circulating through the  system  The BLOWER draws warm cabin air across the fins on the EVAPORATOR where the heat from the air is  transferred to the refrigerant in the evaporator coil  As the refrigerant evaporates from a liquid into a gas it absorbs the  heat from the cabin air  The COMPRESSOR then compresses the refrigerant gas and pumps it through the outer tube       the CONDENSER COIL  The seawater pump circulates cool seawater through the inner tube in the condenser coil   this cools the refrigerant and condenses it into a liquid  The heat from the refrigerant is exchanged to the seawater  and discharged overboard  The liquid refrigerant is then passed through the EVAPORATOR COIL and the cycle  repeats  Removing heat from the cabin air lowers its temperature  The cooled air is blown through the ducting and out  the supply air grille s   For reverse cycle heating  the refrigerant flows in the opposite direction through the reversing  valve  Heat is transferred from the seawater in the condenser coil to the refrigerant and then to the air blowing through  the evaporator into the cabin    PVC FITTING  1 2 HB X 1 2 MPT    CONDENSATE DRAINS SOLID WASHER  The Cabin Mates condensate drain pan is 2  high with three drain LIQUIDE S
9.  Fax   772  581 0056    L 2205M Revised  5 23 05    Georgia    Beard Marine Savannah   Distributor  Location  Savannah  GA  USA  Phone   912  356 5222    Fax   912  692 1006   E mail  beardsav    aol com   Web  www beardmarine com  Hawaii    Southern California Marine Enterprises  Location  San Diego  CA  USA  Phone  619 224 2869    Fax  619 226 0496   E mail  sales    southerncalmarine com   Web  www southerncalmarine com  Idaho    American Marine Contractors  Location  Seattle  WA  USA  Phone   206  660 2240    Fax   206  548 5008  E mail  gene  nwmarineair com  Illinois    Midwest Marine Supply  Location  St  Clair Shores        USA  Phone   586  778 8950   Fax   586  778 6108    Indiana    Midwest Marine Supply  Location  St  Clair Shores        USA  Phone   586  778 8950   Fax   586  778 6108    lowa    Midwest Marine Supply  Location  St  Clair Shores  MI  USA  Phone   586  778 8950   Fax   586  778 6108    Kansas  AER Marine Supply    Location  Seabrook  TX  USA  Phone   281  474 3276    Fax   281  474 2714  E mail  rsmiller 9 aersupply com  Kentucky    Midwest Marine Supply  Location  St  Clair Shores  MI  USA  Phone   586  778 8950   Fax   586  778 6108    Louisiana  AER Marine Supply    Location  Seabrook  TX  USA  Phone   281  474 3276    Fax   281  474 2714  E mail  rsmiller 9 aersupply com  Maine    Ocean Options  Location  Tiverton  RI  USA  Phone   401  624 7334    Fax   401  624 8050   E mail  Sales   oceanoptions com   Web  www oceanoptions com  Maryland    O
10.  Location  Tuzla  Istanbul  Turkey    Phone  90 216 494 2168   Fax  90 216 494 2218  E mail  sales 9 egemar com tr  Web  www egemar com tr    U S  Virgin Islands       Reefco  Inc   Location    St  Thomas  US Virgin Islands       Phone   340  776 0038  Fax   340  776 0038  E mail  denny Q reefco net  Web  www reefco net  Ukraine   Standarte    Location  Starbeevo  Moscow region  Russia    Phone  7 095 575 67 23          7 095 575 39 77  E mail  info   standarte ru  Web  www standarte ru    United Arab Emirates       Mantech    Location  Dubai  United Arab Emirates    Phone   971  4 3332 542           971  4 3330 649    United Kingdom       Dometic Marine   United Kingdom  Sales  Company    Location  Poole  Dorset  England       Phone  44  0  870 3306101   Fax  44  0  870 3306102  E mail  sales 9 dometicmarine com  Web  www dometic com  Uruguay   Baron SRL    Location  San Fernando  Buenos Aires  Argentina    Phone   54  11 4 580 5556  Fax   54  11 4 746 1696  E mail  rosito 9 baron com ar  Web  www baron com ar  Venezuela       Rich Marine Center  Location  Complejo Turistico El Morro  Venezuela  South    America  Phone   58  281 2181630  Fax   58  281 2811630  E mail  richmarine  telcel net ve  Web  www tuyate net    West Indies       Aboard Refrigeration    Location    Antigua  West Indies    Phone   268  460 1690   Fax   419  858 0544   E mail  aboardrf 9 candw ag   Web  www aboardrefrigeration com    Regis Electronics  St Lucia  LTD   Location  St  Lucia  West Indies    P
11.  O circuit board   Send for repair or call local service technician  see distributor listing      Fault  No cooling or heating   Possible Reason Correction    1     Digital control programmed for heat or cool only   Elite Control  Press and release the Mode button  bottom right corner of display  until the desired mode LED is lit     Passport I O Control  Reprogram parameter P 1                  Or      PF    is displayed   See below     Fault  No heat   Possible Reason Correction    1     Digital Control may be set to Electric Heat  not Reverse Cycle   Elite Control  Reprogram parameter P 13    Passport I O Control  Reprogram parameter P 15    Fault  Unit switches to heat while in cool mode   Possible Reason Correction    1     De icing feature enabled due to coil icing up   Elite Control  Reprogram parameter P 7    Passport I O Control  Reprogram parameter P 8    Fault  Fan coil is iced   Possible Reason Correction    1     Improper airflow   See the General Troubleshooting section above first  before reprogramming digital control     Reprogram parameter P 7 for Elite or P 8 for Passport I O  If de icing cycle does not melt ice  switch air conditioning  unit to heat until ice melts or use hair dryer to melt ice     If problem persists  reprogram Low Fan Speed Limit for maximum value  Set P 2 to 55 for Elite or set P 3 to 64 for  Passport I O     Fault  System runs continuously     Possible Reason Correction    1     Improper air sensor location   Verify display head locatio
12.  Web  www marinespecialists com  New Mexico    AER Marine Supply  Location  Seabrook  TX  USA  Phone   281  474 3276    Fax   281  474 2714  E mail  rsmiller  aersupply com  New York    Marine Specialists   Location  Ronkonkoma  NY  USA  Territory  New York  New Jersey  Phone   631  580 0545    Fax   631  580 0551  E mail      Sales marinespecialists com  Web  www marinespecialists com    North Carolina    Beard Marine Savannah   Distributor  Location  Savannah  GA  USA  Phone   912  356 5222    Fax   912  692 1006  E mail  beardsav   aol com  Web  www beardmarine com    North Dakota    Midwest Marine Supply  Location  St  Clair Shores  MI  USA  Phone   586  778 8950   Fax   586  778 6108    Qhio    Midwest Marine Supply  Location  St  Clair Shores  MI  USA  Phone   586  778 8950   Fax   586  778 6108    Oklahoma  AER Marine Supply    Location  Seabrook  TX  USA  Phone   281  474 3276    Fax   281  474 2714  E mail  rsmiller  aersupply com  Oregon    American Marine Contractors  Location  Seattle  WA  USA    Phone   206  660 2240  Fax   206  548 5008  E mail  gene  nwmarineair com    Pennsylvania  Ocean Options   Mid Atlantic    Location  Annapolis  MD  USA  Phone   410  268 9365    Fax   410  268 8199   E mail  Sales   oceanoptions com   Web  www oceanoptions com  Rhode Island    Ocean Options  Location  Tiverton  RI  USA  Phone   401  624 7334    Fax   401  624 8050  E mail  Sales   oceanoptions com  Web  www oceanoptions com    South Carolina    Beard Marine Savannah   Dis
13.  duct bend radius and add the diameter of  he ducting to get total distance as measured from blower outlet   B  When using a transition box consider that each box is unique  o it s application     general rule is to add 1 00   2 54cm   o the largest ring diameter used to get size of box  5  min     Add mount ring and ducting as figured above to get approximate  space needed to install transition box  Also note that the  universal T box is 8 00   20 32cm  tall measured from blower  outlet   4  Allow enough room for removal of electric box cover for servicing   5  Blower may be positioned either horizontal or vertical by removing blower  bracket screws  sliding blower with plate up and out of track  then  slide into desired position and replace screws  TOP VIEW    NOTE  The above dimensions are minimums  Enough space should be  allocated for installation and serviceability        SEE NOTE 2    ELEC BOX  SEE NOTE 4          ROTATED BLOWER POSITIONS  SEE NOTE 5    DUCTING   SEE  NOTE 5    BLOWER  BRACKET  SCREWS    DRAIN PLUG    0 38 1 0     TYPICAL   SIDE VIEW REAR VIEW    MODEL DIMENSIONS  inches milimeters  WEIGHT  NUMBER    D DUCT SIZE QoS AQ        5  CMCP M7K 12 25  311 13  25 337 17  5 451  CMCP M10K 13 00 330 14  25 362 18 25 464    CMCP M12K   14 25 362 14 257362 18 25 464  CMCP M16K    ALL DIMENSIONS ARE Dometic Corporation   Marine Air Systems  NOMINAL   VERIFY ALL            5 16   CABIN MATE  CRITICAL DIMENSIONS SPACING ALLOWANCES AND DIMENSIONS  DATE  01 26 00   DWG
14.  on the data plate label   Passportll display cable is connected at both ends   Pump Relay Panel  if used  has a dedicated circuit breaker sized for the pump but not to exceed 20 amps  maximum    Grilles and Ducting                      Supply air grille mounted as high as possible   Return air grille mounted as low and as close to the a c unit as possible  Return air grille mounted away from bilge vapors or exhaust fumes   Ducting is pulled taut  straight  smooth and properly connected with no excess    OPERATION    OPERATIONS CHECKLIST                      Ensure seawater intake ball valve is open   Turn on the a c circuit breaker  If the seawater pump has its own circuit breaker  turn that on  Turn the system on   Set the desired cabin temperature  set point    Check for a steady solid stream of water from the overboard discharge   Verify that there is steady airflow out of the supply air grille   If the unit does not appear to be operating properly  refer to troubleshooting guidelines    Note  Do not turn the unit off and immediately turn it back on  Allow at least 30 seconds for refrigerant  pressure equalization     L 2271 Cabin Mate  13    MCP OPERATION  3 KNOB           amp  2 KNOB  2KB     1  Ensure seawater intake ball valve  seacock  is open    2  Turn SYSTEM SWITCH control knob to OFF    3  Turn on a c circuit breaker  If the sea water pump has its own  circuit breaker  turn that on too    4  Turn the SYSTEM SWITCH control knob to FAN  2KB  or START   3KB   this e
15.  supply air grille should be  installed to blow freely into the cabin  It should not be installed behind a door or in a close proximity to an adjacent  bulkhead  as this will cause the system to short cycle  In no instance should a supply air discharge be directed  towards a return air grille  as this will also cause the system to short cycle  Allow for adequate clearance behind the  supply air grille s  for the transition box and ducting connection  The following table shows minimum grille sizes  See  the MAINTENANCE section of this manual for return air filter cleaning instructions     DUCTING    Good airflow is critical for the performance of the entire system  It is highly dependent on the quality of the  ducting Installation  The ducting should be run as straight  smooth and taut as possible minimizing the number of 90  degree bends  two tight 90 degree bends can reduce airflow by 2595   The following table shows minimum duct  diameters and their corresponding supply and return air grille minimum areas in square inches  If a transition box is  used  the total area of supply air ducts going out of the box should equal the area of the supply duct feeding the box   To calculate the square inch area of a round duct  multiply the radius by itself       and multiply that number by  3 1416 n                     MODEL 7K 10K 12K 16K  DUCT DIA 5  dia 6  dia 6  dia 7  dia  DUCT AREA 19 6 sq in 28 3 sq in 28 3 sq in 38 5 sq in  R A GRILLE 88 sq in 98 sq in 140 sq in 168 sq in  S A 
16.  tags and labels attached to the unit   Follow all safety codes  Wear safety glasses and work gloves and place a fire extinguisher close to the work area  The  following is a summary of the labels on the unit       DANGER ELECTRICAL SHOCK HAZARD  DISCONNECT VOLTAGE AT MAIN PANEL OR POWER SOURCE BE   FORE OPENING ANY COVER  FAILURE TO COMPLY MAY RESULT IN INJURY OR DEATH       WARNING THIS COMPONENT DOES NOT MEET FEDERAL REQUIREMENTS FOR IGNITION PROTECTION  DO  NOT INSTALL IN SPACES CONTAINING GASOLINE ENGINES  TANKS  LPG CPG CYLINDERS  REGULATORS   VALVES OR FUEL LINE FITTINGS  FAILURE TO COMPLY MAY RESULT IN INJURY OR DEATH     NOTICE THIS COMPONENT IS CHARGED WITH HYDROCHLOROFLUOROCARBON  HCFC  REFRIGERANT R22   EFFECTIVE JULY 1 1992 IT SHALL BE UNLAWFUL FOR ANY PERSON TO KNOWINGLY VENT OR OTHERWISE  KNOWINGLY RELEASE ANY CLASS 1  CFC  OR CLASS 2  HCFC  SUBSTANCE AS A REFRIGERANT IN A MAN   NER WHICH PERMITS SUCH SUBSTANCE TO ENTER THE ATMOSPHERE PER THE CLEAN AIR ACT OF 1990   PUBLIC LAW 101 549 TITLE IV SECTION 608 C  FAILURE TO COMPLY MAY RESULT IN SEVERE PENALTIES   INCLUDING FINES AND IMPRISONMENT       WARNING TO MINIMIZE THE HAZARD OF ELECTRICAL SHOCK AND PERSONAL INJURY  THIS COMPONENT  MUST BE EFFECTIVELY GROUNDED  REFER TO THE INSTALLATION GUIDELINES FOR FURTHER INFORMATION     CAUTION  HIGH COMPRESSOR TEMPERATURE IS NORMAL  DO NOT TOUCH     L 2271 Cabin Mate   4    PLACEMENT OF SYSTEM    Selecting a good location for your air conditioner is the most important pa
17.  the interest of product improvement  Marine Air Systems  specifications and design are  subject to change without prior notice     IF YOU HAVE A DIGITAL CONTROL    Please refer to either the Elite Control manual or the Passport I O Control manual for installation and  operation of those digital control panels  Mechanical control information and wiring diagrams for both  types of controls are in this manual     L 2271 Cabin Mate  2    L 2271 Cabin Mate     TABLE OF CONTENTS    Marine Air Systems        ee eed        4  Clean Air Act Amendments of 1990                                        4  INSTALLATION   Safety Considerations                                                             4  Placement of System  Tools Required                                    5  Spacing Allowances and Dimensions                                     6  How It           amp   er Eee Sendo OU Hot e oet 7  Condensate                                                             7  Mounting Brackets s   oo          baa cea dt 7  Blower                                                           7  Supply  amp  Return Air Grilles                                                     8                 aem eee t e on MERE tcr d pk 8  Seawater Pump and Plumbing                                               9  Cabin Mate Wiring Diagrams                                           10 11  Electrical Connections  Grounding and Bonding                  12  Mechanical Control Panel  MCP  Installation               
18. 0     11    12     13     Digital control is programmed for Cool or Heat only  or mechanical control thermostat is rotated too far  towards either Cooler or Warmer setting   See digital control manual for reprogramming or see mechanical control operation section in this manual     High pressure switch open  in cooling  due to improper seawater flow   Strainer or intake may be plugged  seacock may be closed  check seawater hose for kinks or collapses  Verify pump  operation  Check the pump circuit breaker if applicable       High pressure switch open  in heating  due to improper airflow     Remove any obstructions in return air stream  Clean return air filter and grille  Check for crushed or restricted ducting   ducting must be as straight  smooth and taut as possible     High pressure switch is open in heating mode   System may cycle on high pressure if seawater temperature is above 55 F  12 8 C      Compressor s thermal overload is open due to either of the above reasons   Compressor needs to cool down  Turn system off for a while  it may take up to three hours to reset thermal overload      Fault  No heating   Possible Reason Correction    1     Unit is  cool only   or if reverse cycle  reversing valve may be stuck   Tap reversing valve lightly with rubber mallet while unit is in heat mode  Call for service if that does not correct the  problem     Fault  Low airflow   Possible Reason Correction    1     Airflow is blocked   Remove any obstructions in return air stream  Cle
19. 0 F  Several guidelines  should be followed during the installation of the seawater system  Since the circulation pump is centrifugal and not  self priming  it must be mounted so that it is always at least one foot below the water line regardless of which tack the  vessel is on  The pump may be mounted horizontally or vertically  however the discharge must always be above the  inlet  The pump head should be rotated toward the direction of water flow  Install the seawater speed scoop intake  as far below the water line and as close to the keel as possible in any application  but especially on a sail   boat  to keep the intake in the water so that air does not get into the system when the boat heels over  The  speed scoop intake must face forward and not be shared with any other pump  A seacock  shut off valve  must be  installed directly on the speed scoop outlet  A seawater strainer is mandatory between the seacock and pump  Failure  to install a seawater strainer will void the pump warranty  The seawater system should be installed with an  upward incline from the speed scoop  amp  seacock  through the strainer  to the inlet of the pump and then up to the inlet  of the a c unit s condenser coil  The discharge from the a c unit should then run to the seawater outlet through hull  fitting which should be located where it can be visually checked for water flow and as close as practicable to the  waterline to reduce noise  Use only reinforced marine grade hose  All hose connectio
20. 01   03 and applies only to units equipped with Elite or Passport I O digital controls at the Dometic factory    Components  comprising of the Passport I O circuit boards  Elite or Passport I O digital displays  and associated cables are war   ranted for a period of three  3  years from the date of installation  but not to exceed four  4  years from the date of  manufacture at the Dometic factory  All other components comprising a complete system  excluding pumps and pump  relay panels  on a new installation are warranted for a period of two  2  years from the date of installation  but not to  exceed three  3  years from the date of manufacture at the Dometic factory  Pumps and pump relay panels are  warranted for a period of one  1  year from the date of installation  but not to exceed two  2  years from the date of  purchase  OEM installed equipment warranties begin with the purchase of the vessel  not from the date of installation     Warranty with MCP  Mechanical Control Panel  control  Components comprising a complete system on a new  installation are warranted for a period of one  1  year from the date of installation  but not to exceed two  2  years from  the date of manufacture at the Dometic factory  OEM installed equipment warranties begin with the purchase of the  vessel  not from the date of installation     In addition  Dometic will pay labor costs and travel as outlined in its Schedule of Limited Warranty Allowances for  removal and reinstallation of such compon
21. 04789  E mail  fmtmasb    online sh cn    Costa Rica       Gato Fr  o   Location  Playa Jaco  Costa Rica  Territory  Costa Rica  Panama  Phone  506 637 7181    Fax  506 637 7180  E mail  eric   yachtshare net  Croatia       Dometic Marine   Italy  Sales Company  Location  Milano  Italy  Phone  390 26172583    Fax  390 266010223  E mail  marine info   dometic it  Web  www dometic com  Cyprus    Dometic Marine   United Kingdom  Sales  Company   Location  Poole  Dorset  England   Phone  44  0  870 3306101    Fax  44  0  870 3306102   E mail  sales 9 dometicmarine com   Web  www dometic com  Athens    Aegean Diesel Electric Ltd   Location  Athens  Piraeus  Greece  Territory  Athens   Phone  0030 1 4222484    Fax  0030 1 4175201  E mail  info   ade marine gr  Hong Kong       Eberca    Location    Netherlands    Phone  31 1866 21955  Fax  31 1866 21818  E mail  info   eberca nl    Heinen  amp  Hopman Eng  Bv   Location  Spakenburg  Netherlands  Phone   31   0  33 2992500    Fax   31   0  33 299 2599  E mail  info    heinenhopman com  Web  www heinenhopman com    Netherlands Antilles             Dometic Marine   United Kingdom  Sales  Company   Location  Poole  Dorset  England   Phone  44  0  870 3306101    Fax  44  0  870 3306102  E mail  sales 9 dometicmarine com  Web  www dometic com    Dominican Republic    Piercey Marine Limited  Location  Sai Kung  NT  Hong Kong    Phone   852  2791 4106           852  2791 4124  E mail  pmltd   attglobal net    Italy    Enertech N V    Locati
22. 5 3232   Fax  27 21 555 3230   E mail  info 9 c dynamics co za  Web  www c dynamics co za  Spain   Acastimar    Location  Tarragona  Spain    Phone   349 77 362118  Fax  349 77 362687  E mail  acastimar   acastimar com    Dometic Marine   France  Sales Company  Location  Plailly  France    Phone  Cell  0033  0 680 415 543  Fax  0033  0 344 633 518  E mail  marine sales 9 dometic fr  Web  www dometic com    Techno Electronica Naval  S A     Location  Barcelona  Spain    Phone  34  93  664 49 70  Fax  34  93  665 76 26  E mail      tenGten sa com  Web  www ten sa com  Sri Lanka       G amp M Enterprises  Location  Borella Colombo 8  Sri Lanka    Phone  94 11 2691966          94 11 2691751  E mail  gandMG sltnet Ik    Sweden       Dometic Marine     Nordic Sales  Sales Company  Location  Halmstad  Sweden    Phone  46 35165700   Fax  46 35165710   E mail  marine info  dometic se  Web  www dometic com  Thailand       Thai Kolon Co  Ltd   Location  Bangkok  Thailand    Phone  66 2 745 6468 77  10 lines   Fax  66 2 745 6152  E mail      thkolon  ji net com    Trinidad  amp  Tobago       Nau T Kol Marine Refrigeration    Location  Chaguaramas  Trinidad    Phone  868 634 2174   Fax  868 634 2174   E mail  nautkol  cablenett net  Web  www nautkol com  Turkey       Dometic Marine   United Kingdom  Sales  Company    Location  Poole  Dorset  England    Phone  44  0  870 3306101   Fax  44  0  870 3306102  E mail  sales 9 dometicmarine com  Web  www dometic com    Egemar Muhendiscik Ltd    
23. Air Condition  Location  Fajardo  Puerto Rico  Phone   787  860 2615    Fax   787  801 2050  E mail  cooltech  isppr com  Web  www isppr net cooltech    L 2205M Revised  5 23 05    May Day Marine  Location  San Juan  Puerto Rico    Phone  787 751 0490  Fax  787 790 2551    Sun Cool Air Conditioning   Location  Carolina  Puerto Rico  Puerto Rico  Territory  Carolin   Phone   787  791 6971   Fax   787  791 3885   E mail  suncool1    coqui net    Qatar       Mantech  Location  Dubai  United Arab Emirates    Phone   971  4 3332 542  Fax   971  4 3330 649    Russia       Standarte    Location  Starbeevo  Moscow region  Russia    Phone  7 095 575 67 23          7 095 575 39 77  E mail  info   standarte ru  Web  www standarte ru    Saudi Arabia       Mantech  Location  Dubai  United Arab Emirates    Phone   971  4 3332 542           971  4 3330 649  Scandinavia       Dometic Marine     Nordic Sales  Sales Company    Location  Halmstad  Sweden    Phone  46 35165700   Fax  46 35165710   E mail  marine info  dometic se  Web  www dometic com  Singapore       Tritex Equipment PTE  Ltd   Location    Singapore   Territory  Singapore   Phone   65  6861 1188            65  6861 4263   E mail  angilene  tritex com sg    Slovenia       Dometic Marine   Italy  Sales Company    Location  Milano  Italy    Phone  390 26172583           390 266010223  E mail  marine info   dometic it  Web  www dometic com    South Africa       C Dynamics cc    Location  Cape Town  South Africa       Phone  27 21 55
24. EAL WASHER  locations  During conditions of high humidity  condensate may be  produced at a rate of approximately 2 gallons per hour  With this in  mind  it is important to route condensate drains downward to a sump  pump  It is not recommended to route condensate drains to the bilge   After the condensate drain installation is complete  test the installation  by pouring a quart of water into the pan and checking for good flow        BASE PAN       For installation of the condensate drain   1  Remove the aft facing watertight plug from the base pan of the LOCKING NUT M0070001 DWG   Cabin Mate   unit    Slip the solid washer and the liquid seal washer onto the PVC fitting in that order    Connect the fitting through the exposed hole in the base pan with the locking nut    Securely tighten with two  2  wrenches to provide a proper seal    Attach a 5 8         reinforced hose to the hose barb and secure with stainless steel hose clamps    Install the condensate drain hose downhill from the unit and aft to a sump    Two drain fittings may be used and the hoses teed together provided there is a minimum 2  drop from the   bottom of the base pan to the tee connection                         NOTE  DO NOT TERMINATE CONDENSATE DRAIN LINE WITHIN THREE  3  FEET OF ANY OUTLET OF EN   GINE OR GENERATOR EXHAUST SYSTEMS  NOR IN A COMPARTMENT HOUSING AN ENGINE OR GENERA   TOR  NOR IN A BILGE  UNLESS THE DRAIN IS CONNECTED PROPERLY TO A SEALED CONDENSATE OR  SHOWER SUMP PUMP     MOUNTING BRACK
25. ETS    The a c unit is supplied with a base pan that also serves as a condensate pan   Mounting clip brackets and screws  4  are provided to secure the base pan onto a  flat  horizontal surface     BASE  PAN    BLOWER ROTATION    The Cabin Mate   blower assembly is capable of either horizontal  as shipped from  the factory  or vertical discharge  If vertical discharge is required  then follow these  instructions  Disconnect main power supply  Remove self tapping screws from  blower bracket  shown in drawing   1020043 in this manual  Slide blower assembly  straight up and out of the slotted mounting brackets on the coil shroud  Rotate  blower assembly 90 degrees to desired position  Slide blower assembly back into the mounting slots on both sides of  the shroud  Replace the self tapping screws through the blower bracket into the blower housing  Important  do not use  screws longer than those provided          MOUNTING  BRACKET    M0070002 DWG    L 2271 Cabin Mate  7    SUPPLY  amp  RETURN AIR GRILLES AND TRANSITION BOXES    Install the supply air grille as high as possible in a location that will provide uniform air distribution throughout the  cabin  grille louvers should be directed upward  The return air grille should be installed as low and close to the       unit  as possible to insure direct uninterrupted airflow to the evaporator  The return air grille should have a minimum four  inches  4   of clearance in front of it  free from any furniture or other obstructions  The
26. GRILLE 40 sq in 50 sq in 70 sq in 84 sq in                         The following is a summary of proper ducting connections   1  Pull back the fiberglass insulation exposing the inner mylar duct hose   2  Slide the mylar duct hose around the mount ring until it bottoms out   3  Screw 3 or 4 stainless steel sheet metal screws through the duct hose into the transition ring  Make sure to  catch the wire in the duct hose with the heads of the screws  Do not use band clamps  as the hose will slide off   4  Wrap duct tape around the ducting and ring joint to prevent any air leaks   5  Pull the insulation back up over the mylar to the ring and tape this joint   6  Remove excess ducting and use the same connection method at the supply air grille    All ducting should            appropriately sized for each application  e Run as smoothly and taut as possible  e Have as few bends or loops as possible  e Be securely fastened to prevent sagging during boat operation  e Have all excess ducting lengths trimmed off             be flattened or kinked  e Insulated when located in high heat load areas  hull side  mechanical compartments  etc    e      properly protected against potential damage when routed through open areas    L 2271 Cabin Mate  8    SEAWATER PUMP AND PLUMBING    Seawater temperature will directly affect the a c unit s efficiency  This a c unit can effectively cool your boat in water  temperatures up to 90 F and heat  if reverse cycle option is installed  in water as low as 4
27. S DOUBLE CLAMPED  SEE NOTES  AIR CAN BE TRAPPED                          AIR CONDITIONER  CONDENSING COIL          AIR CONDITIONER  CONDENSING COIL       FLOW                   OUT       SEA WATER  OUTLET    SEA WATER  OUTLET          WATER LINE             1  IXY STRAINER SEA WATER PUMP          BALL VALVE  QZ              SEA WATER PUMP         97 STRAINER       BALL VALVE  VS           ScooP          SAN SCOOP TYPE       THRU HULL INLET HOSE CLAMPS TO BE THRU HULL INLET  REVERSED AS SHOWN  INCORRECT INCORRECT  STRAINER MUST BE BELOW PUMP  PUMP  amp  STRAINER MUST  HOSES MUST BE DOUBLE CLAMPED BE BELOW WATER LINE               AIR CONDITIONER  CONDENSING COIL         MUST BE DOUBLE CLAMPED          AR CONDITIONER       CONDENSING COIL  D     SEA WATER  OUTLET    SEA WATER  OUTLET                y5 STRAINER       BALL VALVE  scoop TYPE VA     L INLET        5                   1    THRU HULL INLET THRU HULI    M5030003 DWG                L 2271 Cabin Mate  9       SLN  66 0c c V                                                   ueunio        SUNEN                           010101       1 Z2H09   0S 2VAO  Z SGI1              1002 1H9IVMIS 3lVW            832Z    229 2   391 4WOWO  WvHOvIQ              0002        NIBVO       EOLOLOLIN   S                          MG   dOIN  37949           ILYN          Z 9191 11NOWO    uoneJodjo                             JIV 9UUeJN    uoneJodJo  oneuloq                    U38NDN luvd    66 02 21     avd     Q310N    5               5531  0
28. a    AER Marine Supply  Location  Seabrook  TX  USA  Phone   281  474 3276    Fax   281  474 2714  E mail    rsmiller 8 aersupply com  Alaska    American Marine Contractors  Location  Seattle  WA  USA  Phone   206  660 2240    Fax   206  548 5008  E mail  gene    nwmarineair com  Arizona    Southern California Marine Enterprises  Location  San Diego  CA  USA  Phone  619 224 2869    Fax  619 226 0496   E mail  sales    southerncalmarine com   Web  www southerncalmarine com  Arkansas    AER Marine Supply  Location  Seabrook  TX  USA  Phone   281  474 3276    Fax   281  474 2714  E mail  rsmiller 9 aersupply com  California    Southern California Marine Enterprises  Location  San Diego  CA  USA  Phone  619 224 2869    Fax  619 226 0496   E mail  sales    southerncalmarine com   Web  www southerncalmarine com  Colorado    AER Marine Supply  Location  Seabrook  TX  USA  Phone   281  474 3276    Fax   281  474 2714  E mail  rsmiller  aersupply com  Connecticut    Ocean Options  Location  Tiverton        USA  Phone   401  624 7334    Fax   401  624 8050   E mail  Sales   oceanoptions com   Web  www oceanoptions com  Delaware    Ocean Options   Mid Atlantic  Location  Annapolis  MD  USA  Phone   410  268 9365    Fax   410  268 8199  E mail  Sales   oceanoptions com  Web  www oceanoptions com    Florida  North     Beard Marine Savannah   Distributor  Location  Savannah  GA  USA  Phone   912  356 5222    Fax   912  692 1006  E mail  beardsav   aol com  Web  www beardmarine com    Flori
29. an return air filter and grille  Check for crushed or restricted ducting   ducting must be as straight  smooth and taut as possible     Fan coil is iced   See below     Fault  Fan coil is iced   Possible Reason Correction    1     Thermostat set point is too low   Raise set point     Improper airflow    Remove any obstructions in return air stream  Clean return air filter and grille  Check for crushed or restricted ducting   must be as straight  smooth and taut as possible  See the Digital Controls Troubleshooting section below for  reprogramming options     Supply air is short cycling   Redirect supply air so that it is not blowing into the return air stream  Seal any air leaks on duct     Humidity level too high   Close hatches and doors     When all else fails   Switch air conditining to heat until ice melts or use hair dryer to melt     L 2271 Cabin Mate  17    Fault  Water coil is iced in the heating mode   Possible Reason Correction    1  Seawater temperature is below 40  F 4 4  C   Shut down system to prevent damage to condenser  Allow coil to defrost     Fault  System runs continuously   Possible Reason Correction    1  Set point temperature is improperly set  too low for cooling or too high for heating   Raise or lower set point     2  Porthole or hatches open   Close all port holes and hatches     3  Seawater temperature too high for cooling or to low for heating   Seawater temperature will directly affect the a c unit   s efficiency  This a c unit can effectively c
30. cabin mate    Installation  Operation and Maintenance       MARINE        SYSTEMS               Revised  5 24 05    L 2271 C        PREFACE    Congratulations on the purchase of your Marine Air Systems  CABIN MATE air conditioner  No matter  which of the following features was the reason for your purchase of this air conditioner  we are sure it will  meet your needs and will give you many years of efficient and trouble free use  The CABIN MATE units  are self contained direct expansion air conditioners designed for marine applications incorporating the  following features       High efficiency rotary compressors   e Cupronickel condenser coil     Raised lance fin designed evaporator coil   e Insulated anti vibration base pan   e  Pre charged and pre wired systems for easy connections     Electrical box with fire retardant cover mounted on unit for access and service    Blower can be repositioned for either vertical or horizontal  standard  discharge    Charge Guard  ensured environmental protection and system integrity    This manual is intended to provide the information necessary to ensure proper installation  operation  and  maintenance of the unit  Improper installation or misunderstood operating procedures can result in unsat   isfactory performance and or premature failure of these units  so before proceeding please read this  manual completely     The CABIN MATE a c units are covered under the existing Marine Air Systems  warranty policy contained    in this manual  In
31. cean Options   Mid Atlantic  Location  Annapolis  MD  USA  Phone   410  268 9365    Fax   410  268 8199  E mail  Sales   oceanoptions com  Web  www oceanoptions com    Massachusetts    Ocean Options  Location  Tiverton  RI  USA  Phone   401  624 7334    Fax   401  624 8050   E mail  Sales    oceanoptions com   Web  www oceanoptions com  Michigan   Midwest Marine Supply    Location  St  Clair Shores  MI  USA  Phone   586  778 8950    Fax   586  778 6108  Minnesota  Midwest Marine Supply    Location  St  Clair Shores  MI  USA   Phone   586  778 8950   Fax   586  778 6108  Mississippi   AER Marine Supply   Location  Seabrook  TX  USA   Phone   281  474 3276    Fax   281  474 2714  E mail  rsmiller  aersupply com  Missouri    AER Marine Supply  Location  Seabrook  TX  USA  Phone   281  474 3276    Fax   281  474 2714  E mail  rsmiller  aersupply com  Montana    American Marine Contractors  Location  Seattle  WA  USA  Phone   206  660 2240    Fax   206  548 5008  E mail  gene  nwmarineair com  Nevada    AER Marine Supply  Location  Seabrook  TX  USA    Phone   281  474 3276  Fax   281  474 2714  E mail  rsmiller  aersupply com    New Hampshire  Ocean Options    Location  Tiverton  RI  USA  Phone   401  624 7334    Fax   401  624 8050   E mail  Sales   oceanoptions com   Web  www oceanoptions com  New Jersey    Marine Specialists   Location  Ronkonkoma  NY  USA  Territory  New York  New Jersey  Phone   631  580 0545    Fax   631  580 0551   E mail      Sales marinespecialists com  
32. da  South     ARW Maritime   Dealer  Location  Ft  Lauderdale  Florida  USA  Territory  Fort Lauderdale    Phone   954  463 0110  Fax   954  522 1139  E mail  arwgroup  earthlink net    Beard Marine   Ft  Lauderdale   Dealer  Location  Ft  Lauderdale  Florida  USA  Territory  Fort Lauderdale   Phone   954  463 2288    Fax   954  527 0362  E mail  info 9 beardmarine com  Web  www beardmarine com    Beard Marine of the Palm Beaches   Dealer  Location  Riviera Beach  Florida  USA  Territory  Riviera Beach    Phone   561  881 9598  Fax   561  881 9599  E mail  bmpb   beardmarine com    Cable Marine   Dealer  Location  Ft  Lauderdale  Florida  USA  Territory  Fort Lauderdale    Phone   954  462 2840  Fax   954  523 3686  Web  www cablemarine com    Comfort Marine   Dealer  Location  Ft  Lauderdale  FL  USA  Territory  Ft  Lauderdale    Phone   954  257 9848  Fax   954  689 7332    Cowherd Marine   Dealer  Location  Lake Park  Florida  USA  Territory  West Palm Beach    Phone   561  844 1666  Fax   561  844 1628    Dometic Corporation Environmental Systems   Distributor   Location  Pompano Beach  FL  USA   Territory  South Florida   Phone   954  973 2477    Fax   954  979 4414  E mail  sales 9 dometicenviro com  Web  www dometicenviro com    Edd Helms Marine Air Conditioning   Dealer  Location  Miami  Florida  USA  Territory  Ft  Lauderdale  Miami    Phone  954522 2520          954 522 1331               srogers    eddhelms com    Florida  South     IYS Marine   Dealer  Location  P
33. ed to be drained of water    3  Use of pressurized air injected at the overboard discharge fitting and the water being discharged through the  seawater intake fitting    4  Use of pressurized air to force water from the intake through the overboard discharge     Note  Collect all discharged liquids and recycle or dispose of in a proper manner     Any method that causes the anti freeze solution to flow downward is the method of choice  By this means  the anti   freeze solution will displace any water trapped and eliminate the possibility of freezing in hidden areas     In addition  since the seawater pump utilizes a magnetically driven impeller  the impeller should be removed from the  wet end assembly  wiped with an alcohol solution  and stored in a warm  dry area until commissioning takes place     L 2271 Cabin Mate  15    GENERAL TROUBLESHOOTING    Also see specific digital or mechanical control troubleshooting sections following these general  guidelines     Fault  Will not start   Possible Reason Correction    1     Air conditioning circuit breaker is off   Turn circuit breaker on at ship s panel     Control is not turned on   See mechanical control section of this manual for MCP controls  or see the digital control manual for Elite or Passport       controls     Wrong wiring at terminal strip   Check wiring diagram and correct if necessary     Push on butt connectors became disconnected during installation   Disconnect power supply and open electric box  check wiring dia
34. ents for a period of one  1  year from the date of installation  but not to  exceed two  2  years from the date of manufacture at the Dometic factory  OEM installed equipment warranties begin  with the purchase of the vessel  not from the date of installation  Warranty will be paid in accordance with our estab   lished schedule of allowances  Compensation for warranty repairs is only made to Dometic authorized service compa   nies     Dometic will repair  or replace at its option  components found to be defective due to faulty materials or workmanship   when such components  examined by an authorized service dealer or a factory service representative  are found to  have a defect for which the company is responsible  Refer to Manufacturer s Limited Warranty Policy for complete  coverage and exclusions  Replacement components are warranted for the duration of the remaining warranty period in  effect on the original component  In the event that a unit has to be returned to the factory  it must be properly pack   aged to prevent shipping damages  If packaging is not available  Dometic will provide it at no charge  The warranty  may be voided on any piece of equipment or component that is damaged due to improper packaging     This limited warranty is extended in lieu of all other warranties  agreements or obligations  expressed or implied   concerning Dometic s components  This warranty is extended only to the original purchaser and is not transferable   This warranty shall be gov
35. erned by the laws of the State of Florida and gives the original first end user definite legal  rights     This warranty does not cover damages incidental and or consequential to the failure of Dometic s equipment including  but not limited to  normal wear  accident  misuse  abuse  negligence  improper installation  lack of reasonable and    necessary maintenance  alteration  civil disturbance or acts of God     No person or dealer is authorized to extend any other warranties or to assume any other liabilities on Dometic s  behalf  unless made or assumed in writing by an officer of Dometic     L 2271 Cabin Mate  22    Marine Air Worldwide Service Dealer Locator    The majority of the service listings displayed for the United States are key members of the national Marine Air distributor network  If  you need service  please contact the closest company shown  In most cases they will direct you to a local dealer or service port   We have over 500 Marine Air dealers in the national Marine Air network  and one should be convenient to you     The international companies listed are  in many cases  distributors and are capable of managing the majority of service requests  for the countries listed  In some cases they will refer you to a local dealer     You may also contact us directly via the web site or call us in the US at  954  973 2477     For a complete and up to date Dealer locator list  please visit our website at http   www marineair com locator index html    USA       Alabam
36. es   dometic fr  Web  www dometic com    PolyMarine Distribution  C O Occas Marine   Location  Le Cannet  Rocheville  France    Phone  0033 493463634  Fax  0033 493463634  E mail  polymarine bayle  free fr    French West Indies    Dometic Marine   United Kingdom  Sales  Company   Location  Poole  Dorset  England   Phone  44  0  870 3306101    Fax  44  0  870 3306102  E mail  sales 9 dometicmarine com  Web  www dometic com    Inmartech Ltd   Location  Swieqi  STJ 04  Malta    Phone  00356 21376476  Fax  00356 21376476    Mexico    Gato Fr  o  Location  Playa Jaco  Costa Rica  Territory  Costa Rica  Panama    Phone  506 637 7181  Fax  506 637 7180  E mail  eric 9 yachtshare net    Productos Marine Air  Location  La Chorrea  Panama    Territory  Panama  Phone  507 232 5406    Fax  507 232 7648  E mail  masters    sinfo net  Portugal       PowerCool Lda  Location  Portimao  Portugal  Territory  Portugal  Phone  35191 786 63 73    Fax  351 282 461 818  E mail  info 9 powercool org  Web  www powercool org    Puerto Rico             Caraibes Distribution  Location  Marin  Martinique  French West Indies    Phone   0596 257292  Fax  0596 747353    Southern California Marine Enterprises  Location  San Diego  CA  USA  Phone  619 224 2869    Fax  619 226 0496  E mail  sales    southerncalmarine com  Web  www southerncalmarine com    Centro Cruisair de Puerto Rico  Location  San Turce  Puerto Rico    Phone  787 727 3637  Fax  787 727 3637  E mail  fernan_moreno   hotmail com    Cool Tech 
37. gram  correct if necessary    Input line voltage is insufficient   Check power source  shore generator  for proper voltage  Check wiring and terminals for proper sizes and  connections  Verify with a voltmeter that the power at the unit is the same as the power source     Fault  Fan is not running     Check specific control troubleshooting section     Fault  No cooling or heating   Possible Reason Correction    1     Temperature set point is satisfied   Lower or raise set point     Obstructed seawater flow   Clean seawater strainer  Check for obstructions at speed scoop thru hull inlet  Check for a good steady flow from the  overboard discharge     Seawater pump may be air locked   Remove hose from pump discharge to purge air from line     Loss refrigerant gas   Check air conditioning unit for refrigerant oil leakage  call service technician     Seawater temperature too high for cooling or too low for heating    Seawater temperature will directly affect air conditioning unit s efficiency  This air conditioning unit can effectively cool  your boat in water temperature up to 90  F  32 2  C  and heat  if reverse cycle option is installed  in water as low as  40  F  4 4  C      Fan coil is iced  in cooling    Check your specific control troubleshooting section     Fan is not running   Check your specific control troubleshooting section     Seawater plumbing is air locked   Ensure that seawater plumbing is installed per the guidelines in this manual     L 2271 Cabin Mate   16    1
38. he return air  stream  Make electrical connections according to the wiring diagrams     L 2271 Cabin Mate  12    INSTALLATION CHECKLIST  review prior to installation     Seawater cooling system                             Speed scoop located as far below the waterline and as close to the keel as possible   Shut off valve and speed scoop properly sealed and tight   Seawater pump at least one foot below waterline and securely mounted   Strainer mounted below pump with access to filter   Double reversed stainless steel hose clamps on all hose connections   Teflon tape on all threaded connections   Hose runs uphill from speed scoop and seacock to strainer  pump and a c unit  then downhill from a c unit to  overboard discharge   Water flowing freely from overboard discharge while pump is running    Mounting                            Not In engine room      bilge areas  must be sealed away from exhaust      fumes  Proper spacing allowed around unit for hose and duct connections and for serviceability  Attached to solid level platform with hold down clips provided   Condensate drain routed aft and down hill to a sealed sump  not bilge    Blower rotated toward supply air grille    Electrical                         All butt connections on pump wire tightly crimped and heat shrunk   AC power source installed and grounded bonded in accordance with ABYC standards   Control wires connected to terminal strip with fork or ring terminals   Circuit breakers sized according to specifications
39. hone  758 452 0205  Fax  758 452 0206  E mail  stlucia   regiselectronics com    Yemen       Mantech  Location  Dubai  United Arab Emirates    Phone   971  4 3332 542  Fax   971  4 3330 649    L 2205M Revised  5 23 05    For service of product purchased  through a catalog or chain store  please  call our Ocean Marketing Customer  Service Hot Line     888  452 0349        M Dometic     Dometic Environmental Corporation    Dometic       sign of             2000     Andrews Ave  Ext  e Pompano Beach  FL 33069 1497 USA     Phone  954 973 2477     Facsimile  954 979 4414    For Sales and Service Calls within Europe and the Middle East  please contact  44  0  870 330 6101  Website  www marineair com     Email  sales   marineair com L 2271    
40. inellas Park  Florida  USA  Territory  Tampa St Petersburg    Phone   727  521 6650  Fax   727  520 0844  E mail  iysmarine2002   aol com    Jim s Marine A C   Dealer  Location  Port Charlotte  Florida  USA  Territory  Port Charlotte   Phone   941  629 8788    Marine Air Conditioning   Dealer  Location  Ft  Pierce  Florida  USA  Territory  Port St  Lucie    Phone   772  464 7896  Fax   772  464 8697    Masters Marine Center  Inc    Dealer  Location  Miami  Florida  USA   Territory  Miami   Phone   305  891 1236   Fax   305  891 8700    Neptune Air Corporation   Dealer  Location  Ft  Lauderdale  Florida  USA  Territory  Fort Lauderdale    Phone   954  792 6550  Fax   954  792 6551    Palm Beach Aqua Air   Dealer  Location  West Palm Beach  Florida  USA  Territory  West Palm Beach    Phone   561  832 8820  Fax   561  659 7918    Sea Air Land Technologies   Dealer  Location  Marathon  Florida  USA  Territory  Florida Keys   Phone   305  289 1150    Fax   305  359 5272  E mail  saltmail   aol com  Web  www salt systems com    Sea Breeze Marine   Dealer  Location  Lighthouse Point  Florida  USA  Territory  Lighthouse Point    Phone   954  427 3843  Fax   561  368 0463    Tropica Boats  amp  Marine  Inc    Dealer  Location  Fort Myers  Florida  USA   Territory  Fort Myers   Phone   239  694 5259    Fax   239  694 5243  E mail  info  tropica net  Web  www tropica net    Ty Cobb Services  Inc    Dealer  Location  Sebastian  Florida  USA  Territory  Sebastian    Phone   772  388 5966 
41. ir flow condition  This type of installation will  prevent short or premature cycling     The unit should be positioned on a firm  level  horizontal surface and the condensate drain line should run downward  and aft from the unit to a suitable drain location sealed away from any exhaust or bilge vapors  Plan all connections  which must be made prior to starting installation  including ducting  condensate drain  cooling water in and out   electrical power connections  location of control panel  and seawater pump placement and plumbing  to assure easy  access for installation and servicing     L 2271 Cabin Mate   5    PROPRIETARY NOTE  THE INFORMATION CONTAINED DATE REVISION DESCRIPTION  WITHIN THIS DOCUMENT IS THE PROPERTY OF DOMETIC   CORPORATION  ANY ATTEMPT TO COPY OR Bien Ure   A   2 16 00   ADDED DOWNPIPE TO COND  COIL DCRACADO70 00 Hs  RP  WITHOUT WRITTEN CONSENT FROM DOMETIC   B   7 301   REVISE PROJECTIONS  ADD VIEW CALLOUTS  CAD622 01  CORPORATION SHALL BE CONSIDERED UNLAWFULAND   C   2 9 04   REVISED DIMENSIONS  ADD 5K  ADD DUCT SIZE  CAD083 04    Plotted   17 Oct 01     03 18 pm       SPACE ALLOWANCES TO CONSIDER WHEN DESIGNING AREA FOR A C UNITS    1  Allow a minimum 3 00   7 62cm  of air space in front of evaporator  for return air intake if it is adjacent to a bulkhead   2  A minimum of 4 00   10 16cm  is required for clamping seawater  connections   3  For flexible ducting connection   If mount ring is used  allow 2 00   5 08cm  for the ring   1 00   2 54cm  for
42. lay cable   Unplug alternate air sensor if installed or plug in alternate air sensor if not installed  Try another display cable     Damaged jack socket in display head or on circuit board   Visually check to see that pins inside socket are not bent or corroded  Repair or replace display or circuit board if  needed     Fault     PLF    is displayed  Elite Digital Control only    Possible Reason Correction    1     Indicates that seawater flow through the condenser coil is insufficient   Check for adequate seawater flow  Verify pump operation  Inspect the condenser coil  it may need cleaning  see  MAINTENANCE section   Sensor may be faulty  replace if necessary  Call for service technician     L 2271 Cabin Mate  20    MCP Mechanical Control Panel    Fault  Fan is not running   Possible Reason Correction    1     3 Knob MCP system switch is not set properly   Set MCP system switch to  START  for fan only or  HUN  for cooling and heating  if reverse cycle      3 Knob MCP fuse blown   Replace 10 amp fuse behind MCP panel     2 knob MCP system switch is not set properly   Set system switch to  FAN  for fan only or  COOL  for cooling and heating     Wire became disconnected or loosened during installation   Reconnect or tighten  verify with wring diagram in this manual     Fault  System runs continuously     Possible Reason Correction    1     Improper MCP air sensor location   Verify return air sensing bulb location with criteria found in this manual     Fault  No cooling or heati
43. n with criteria found in the control manual  Install alternate air sensor if necessary     L 2271 Cabin Mate   19    Fault     HPF    is displayed   Possible Reason Correction    1     High pressure switch is open  in cooling  due to improper seawater flow   Strainer or intake may be plugged  seacock may be closed  check seawater hose for kinks or collapses  Verify pump  operation  check pump circuit breaker if applicable     High pressure switch open  in heating  due to improper airflow   Remove obstructions in return air stream  Clean air filter and grille  Check for crushed or restricted ducting  ducting  must be as straight  smooth and taut as possible     If problem persists  reprogram Low Fan Speed Limit for maximum value  Set P 2 to 55 for Elite or set P 3 to 64 for  Passport I O  And  set the Reverse Fan Speeds During Heating Mode parameter to  rEF   P 12 for Elite or P 13 for  Passport I O   or manually set fan speed to high     Fault   LPF  is displayed   Possible Reason Correction    1     Low pressure switch is open due to low seawater and or low return air temperatures   Try restarting the a c unit  the optional low pressure switch has a ten minute shutdown time delay that may be in  affect     Low pressure switch is open due to loss of refrigerant   Check air conditioning unit for refrigerant oil leakage  call service technician     Fault   ASF  is displayed   Possible Reason Correction    1     Indicates failed faceplate air sensor  alternate air sensor or disp
44. nergizes the fan and seawater pump  3KB  see note    Turn THERMOSTAT control knob to the coolest position by rotating  it fully clockwise  If system has reverse cycle  turn knob counter   clockwise for heat    5  Turn FAN SPEED control knob to highest setting             6  Verify that the fan is running and that there is steady airflow out of  the supply air grille    7  Turn the SYSTEM SWITCH to RUN  this will start the compressor  and seawater pump  2KB  see note   The indicator light on the 3KB  control will illuminate    8  Check for a steady solid stream of seawater from the overboard  discharge    9  To set the thermostat  allow sufficient time for the unit to cool heat  the area to the desired temperature  When the area is sufficiently  cooled heated  turn the thermostat knob slowly toward the center  position until it clicks once  the indicator light on the        will turn  off   The thermostat is now set to maintain a constant temperature   While heating  if the ambient temperature is less than 50 F  10 C    set the FAN SPEED control knob to low  3KB  for five to ten  minutes until the unit begins to heat well  then increase the fan  speed for more heat output     Note  The seawater pump comes on with the fan on the 3KB  switch set  to START  and with the compressor on the 2KB  switch set to RUN      The thermostat on the MCP control panel serves to cycle the compressor  on and off and provide an automatic changeover from cooling to heating   reverse cycle only  wi
45. ng   Possible Reason Correction    1     High pressure switch is open  in cooling  due to improper seawater flow   Strainer or intake may be plugged  seacock may be closed  check seawater hose for kinks or collapses  Verify pump  operation  Check the pump circuit breaker if applicable     High pressure switch open  in heating  due to improper airflow   Remove any obstructions in return air stream  Clean return air filter and grille  Check for crushed or restricted  ducting  ducting must be as straight  smooth and taut as possible     MCP is not set properly   3 knob should be set to    RUN     2 knob should be set to COOL      L 2271 Cabin Mate  21    MANUFACTURERS LIMITED WARRANTY AGREEMENT    The following warranty is extended to cover marine air conditioners manufactured or supplied by Dometic Environmental  Corporation  and is subject to qualifications indicated  Dometic warrants for the periods set forth below that products  manufactured or supplied by it will be free from defects in workmanship and material  provided such products are in   stalled  operated  and maintained in accordance with Dometic s written instruction     ALL IMPLIED WARRANTIES INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE   ARE LIMITED TO THE TERMS AND PERIODS OF WARRANTY SET FORTH BELOW AND  TO THE EXTENT  PERMITTED BY LAW  ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED     Warranty with the Elite or Passport I O digital controls  Coverage applies to units manufactured on or after 03 
46. ns shall use double reversed  stainless steel hose clamps  Below is a summary of the seawater system installation     1     On            x    Install the speed scoop thru hull inlet as close to the keel and as far below the waterline as possible  facing  forward  Bed the scoop with a marine sealant designed for underwater use    Install a bronze  full flow seacock on the speed scoop thru hull inlet    Install a seawater strainer below the level of the pump with access to filter    Mount the pump at least one foot below the waterline and above the strainer    Connect the seacock  strainer and pump with an uphill run of reinforced marine hose    Connect the discharge from the pump uphill to the inlet of the a c unit s condenser coil  And connect the outlet  of the condenser coil to the overboard discharge thru hull  seawater outlet     Avoid loops  vertical bends  high spots  or the use of 90  elbows with seawater hose  each 90  elbow is equiva   lent to 2 5  of hose and a 90  elbow on the pump is equivalent to 20  of hose     Double clamp all hose connections with stainless steel clamps  reversing the clamps    Use teflon tape on all threaded connections       Connect all metallic parts in contact with seawater to the vessel s bonding system including thespeed scoop    inlet  strainer  pump  and the air conditioner  Failure to do so will void warranty     STEADY UPWARD FLOW FROM INLET HOSES MUST NOT HAVE KINKS   TO UNIT THEN DOWNWARD TO OUTLET  LOOPS OR HIGH SPOTS WHERE  HOSE
47. on  Simpson Bay  St  Maarten St  Martin  Netherland  Antilles   Phone  599 551 2145   Fax  305 675 5857  USA    E mail  service   entertechnv com    New Zealand             May Day Marine  Location  San Juan  Puerto Rico    Phone  787 751 0490  Fax  787 790 2551    Ecuador    Condaria 87 SRL  Location  Nova Milanese  MI   Italy    Phone  390362 44182          39 0362 452226    Dometic Marine   Italy  Sales Company  Location  Milano  Italy  Phone  390 26172583    Fax  390 266010223  E mail  marine info   dometic it  Web  www dometic com  Japan    Whiting Power Systems   Location  192 Herne Bay  Auckland  New Zealand  Phone  649 358 2050   Fax  649 358 0285   E mail  sales    whiting co nz   Web  www whiting co nz    Oman       Mantech  Location  Dubai  United Arab Emirates    Phone   971  4 3332 542  Fax   971  4 3330 649    Panama             Quasar Nautica  S A   Location  P O  Box 17 01 0069  Quito  Ecuador    Phone   593  2 446 996 997  Fax   593  2 436 625    Egypt    Tominaga  amp  Company  Ltd   Location  Osaka  Japan    Phone   816 6365 5010  Fax  816 6365 6294  E mail  nishi  mail tomco co jp    Kuwait          Engineering Air  Location  Abasia  Cairo  Eygpt    Phone  202 4829341  Fax  202 4829341    France    Mantech  Location  Dubai  United Arab Emirates    Phone   971  4 3332 542  Fax   971  4 3330 649    Malta          Dometic Marine   France  Sales Company  Location  Plailly  France  Phone  Cell  0033  0 680 415 543    Fax  0033  0 344 633 518  E mail  marine sal
48. ool your boat in water  temperatures up to 90  F  32 3  C  and heat  if reverse cycle option is installed  in water as low as 40  F  4 4  C      4  Improper air sensor location   Check your specific control troubleshooting section     Digital Controls Troubleshooting  Fault  Digital display panel is not lit   Possible Reason Correction    1  8 pin display cable plugs are not making contact  unplugged  dirty  bent  or broken pins    With POWER OFF at the circuit breaker  remove connector and inspect  If damaged  replace connector or entire  display cable     Fault  Fan is not running or runs continuously   Possible Reason Correction    1  Digital control is programmed for either fan cycling with compressor or continuous fan operation   Elite Control  Press and hold the fan button for five seconds to change to  con  so fan will stay on continuously or to   CYC  so the fan cycles with the compressor     Passport I O Control  Reprogram parameter P 14     Note  After the compressor cycles off  the fan will continue to run for two minutes in Cool Mode and four minutes in  Heat Mode regardless of parameter setting     Fault  Fan is not running but the compressor is   Possible Reason Correction    1  Failed triac on Passport       circuit board   Send for repair or call local service technician  see distributor listing      L 2271 Cabin Mate  18    Fault  Fan runs continuously although it is set to cycle with compressor   Possible Reason Correction    1     Failed triac on Passport I
49. rt of your preparations  Be sure to consider  the size of the area you are cooling  the air distribution needs  and the size of the unit you have chosen  Keeping in  mind that cool air has a tendency to fall  it is highly recommended that you locate the supply air grille as high as  possible in the cabin  See diagram below     Tools required  Screwdrivers  Pliers  Pipe wrench  Wire cutters crimpers  Drill  amp  7 8  bit                   SITION BOX          FLEXIBLE DUCT    Jig saw       RETURN AIR Duct tape  GRILLE TO MATCH Electrical tape  EVAPORATOR COIL   SURFACE AREA Teflon tape      Beding compound to seal     thru hull fittings   BC ELECTRICAL  BUX Hardware to secure unit   pump  strainer  grilles  amp     control panel         TRANSITION BOX   DUAL DUCT INSTAL   LATION ONLY              NOTE   SEAWATER ASSEMBLY  MUST BE INSTALLED  BELOW WATER LINE   WITH STRAINER BELOW  PUMP AND THRU HULL  FITTING BELOW STRAINER             D   2           CONDENSATE  DRAIN            SEAWATER PUMP OVERBOARD    DISCHARGE    SEAWATER STRAINER SHUT OFF VALVE    THRU HULL FITTING  M1030010 DWG oc  CLAM SHELL SCOOP     The CABIN MATE   unit should be installed as low as possible  BUT NEVER IN THE BILGE OR ENGINE ROOM  AREAS  INSURE THAT THE SELECTED LOCATION IS SEALED FROM DIRECT ACCESS TO BILGE AND OR  ENGINE ROOM VAPORS  Installing the unit as low as possible  such as under a V berth  dinette seat or bottom of a  locker  and ducting the supply air as high as possible  creates an ideal a
50. th a 3 5 F  6 3 C  differential  Rotating the thermo   stat to the left after it has been set for cooling will cause the unit to heat   If you rotate the thermostat to the right  the unit will cool  If the thermo   stat is left stationary after being set  the unit will cycle from cooling to  neutral  or heating to neutral depending on the requirement     IMPORTANT NOTE  Reverse cycle units have a reversing valve that  must be energized periodically to keep the internal parts moving freely  To  accomplish this  switch the a c into HEAT for a few seconds once a  month     Note  Do not turn the unit off and immediately turn it back on  Wait  at least 30 seconds for system refrigerant pressures to balance     L 2271 Cabin Mate  14      3 75  PANEL    3 KNOB CONTROL  MCP           7 0    CUT OUT  8 50  PANEL    THERMOSTAT    MARINE  li AIR SYSTEMS o    o  ARRS           2 5 CUT OUT    2 KNOB CONTROL  MCP2KB           4 5    CUT OUT  5 50    PANEL    THERMOSTAT       4        E                   MARINE AIR SYSTEMS o    ARR     POMPANO BEACH  FLORIDA U     2 5    CUT OUT    3 25  PANEL    M4070003 0WG    pie                                 Seawater Strainer   Insure that your pump receives adequate seawater flow by regularly cleaning the strainer basket  Periodically check  the overboard discharge for a steady stream of water  Check seawater intake speed scoop for obstructions  Make sure  hoses are not looped  kinked or crushed     Condenser Coil Cleaning   Coils can become fouled o
51. tributor  Location  Savannah  GA  USA  Phone   912  356 5222    Fax   912  692 1006  E mail  beardsav   aol com  Web  www beardmarine com    South Dakota    Midwest Marine Supply  Location  St  Clair Shores  MI  USA  Phone   586  778 8950   Fax   586  778 6108    Tennessee    Beard Marine Savannah   Distributor  Location  Savannah  GA  USA  Phone   912  356 5222    Fax   912  692 1006   E mail  beardsav   aol com   Web  www beardmarine com  Texas    AER Marine Supply  Location  Seabrook  TX  USA    Phone   281  474 3276  Fax   281  474 2714  E mail  rsmiller  aersupply com    L 2205M Revised  5 23 05    Utah    AER Marine Supply  Location  Seabrook  TX  USA  Phone   281  474 3276    Fax   281  474 2714  E mail  rsmiller 9 aersupply com  Vermont    Ocean Options  Location  Tiverton  RI  USA  Phone   401  624 7334    Fax   401  624 8050   E mail  Sales   oceanoptions com   Web  www oceanoptions com  Virginia    Ocean Options   Mid Atlantic  Location  Annapolis  MD  USA  Phone   410  268 9365    Fax   410  268 8199   E mail  Sales   oceanoptions com   Web  www oceanoptions com  Washington    American Marine Contractors  Location  Seattle  WA  USA  Phone   206  660 2240    Fax   206  548 5008  E mail  gene  nwmarineair com  West Virginia    Ocean Options   Mid Atlantic  Location  Annapolis  MD  USA  Phone   410  268 9365    Fax   410  268 8199   E mail  Sales   oceanoptions com   Web  www oceanoptions com  Wisconsin    Midwest Marine Supply   Location  St  Clair Shores        USA
52. trip at the electrical  box  If two or more a c units use the same seawater pump  the pump wires will be connected to a pump relay panel  PRP   which in turn has its own dedicated circuit breaker sized for the pump  20 amp max   Please see the wiring diagram  furnished with the PRP  NOTE  PRP triac must have mounting screw installed in order to dissipate heat   Connections in  the bilge below the waterline should use heat shrink type butt splices     Field wiring must comply with ABYC electrical codes  Power to the unit must be within the operating voltage range indi   cated on the data plate  Properly sized fuses or HACR circuit breakers must be installed for branch circuit protection  See  data plate for maximum fuse circuit breaker size  mfs  and minimum circuit ampacity  mca   All units must be effectively  grounded to minimize the hazard of electrical shock and personal injury  The following are to be observed    1  AC  alternating current  grounding  green wire  must be provided with the AC power conductors and connected  to the ground terminal  marked  GRND   at the AC power input terminal block of the unit s   per ABYC stan   dard E 8  or equivalent    2  Connections between the vessel s AC system grounding conductor  green wire  and the vessels DC  direct  Current  negative or bonding system should be made as part of the vessel s wiring  per ABYC standard E9  or  equivalent    3  When servicing or replacing existing equipment that contains a chassis mounted ground st
53. ud  the service  person or installer must check the vessel s wiring for the existence of the connection required in item 2 above     ABYC standards are available from  American Boat and Yacht Council  3069 Solomon   s Island Rd   Edgewater  MD 21036  Telephone   410  956 1050    The a c unit must be connected to the vessel s bonding system to prevent corrosion due to stray electrical  current or voltage  All pumps  metallic valves and fittings in the seawater circuit that are isolated from the a c unit by  PVC or rubber hoses must be individually bonded to the vessel s bonding system also  This will help eliminate any  possibility of corrosion due to stray current or voltage     FAILURE TO PROPERLY GROUND AND BOND THE SYSTEM WILL VOID WARRANTY     MANUAL CONTROL PANELS  MCP  INSTALLATION    The MCP should be located within cap tube length of the CABIN MATE   unit  The cut out size for the 2 knob MCP is  2 5  wide by 4 5  tall  The 3 knob MCP is configured either vertically or horizontally  The cut out size is 2 5  by 7 0    see MCP for orientation  Once the cut out is made  carefully uncoil the copper cap tube with return air sensor  copper  bulb  and route the control wires and cap tube through the hole and back to the unit using caution not to kink the  cap tube  Mount the return air sensor into the clips provided on the evaporator coil  If the return air sensor cannot be  mounted on the evaporator coil  mount it behind the return air grille  The sensor must be mounted in t
54. uerto Rico    Phone  787 727 3637  Fax  787 727 3637  E mail  femrnan moreno   hotmail com    Cool Tech Air Condition  Location  Fajardo  Puerto Rico  Phone   787  860 2615    Fax   787  801 2050   E mail    cooltech                      Web  www isppr net cooltech   Enertech N V    Location  Simpson Bay  St  Maarten St  Martin  Netherland  Antilles   Phone  599 551 2145   Fax  305 675 5857  USA    E mail  service   entertechnv com    Freezing Point  Ltd   Location  Nassau  Bahamas  Territory  Nassau    Phone   242  325 3589  Fax   242  356 5271  E mail  rolandknowles   bahamas net bs    May Day Marine  Location  San Juan  Puerto Rico    Phone  787 751 0490  Fax  787 790 2551    Nau T Kol Marine Refrigeration  Location  Chaguaramas  Trinidad  Phone  868 634 2174    Fax  868 634 2174   E mail  nautkol   cablenett net  Web  www nautkol com  Reefco  Inc     Location    St  Thomas  US Virgin Islands  Phone   340  776 0038    Fax   340  776 0038  E mail  denny  reefco net  Web  www reefco net    Regis Electronics  St Lucia  LTD   Location  St  Lucia  West Indies    Phone  758 452 0205  Fax  758 452 0206  E mail  stlucia   regiselectronics com    Sun Cool Air Conditioning  Location  Carolina  Puerto Rico  Puerto Rico  Territory  Carolin    Phone   787  791 6971  Fax   787  791 3885  E mail  suncool1  coqui net    L 2205M Revised  5 23 05    China    Greece    Netherlands       Flash Marine Trading Pte Ltd   Location  Shanghai  China    Phone   86 21  509 04120           86 21  509 
55. unert  and Sentry     CLEAN AIR ACT AMENDMENTS OF 1990  TITLE VI   SECTION 608 C 1       Effective July 1  1992  it shall be unlawful for any person  in the course of maintaining  servicing  repairing  or  disposing of an appliance or industrial process refrigeration  to knowingly vent or otherwise knowingly release or  dispose of any Class 1  or Class II   substance used as a refrigerant in such appliance  or industrial process refrig   eration  in a manner which permits such substance to enter the environment  De minimis releases associated with  good faith attempts to recapture and recycle or safely dispose of any such substances shall not be subject to the  prohibition set forth in the proceeding sentence         Class substances include CFC 12      Class      substances include HCFC 22    INSTALLATION  SAFETY CONSIDERATIONS    VERY IMPORTANT  Never install your air conditioner In the bilge or engine room areas  Insure that the selected  location is sealed from direct access to bilge and or engine room vapors  Do not terminate condensate drain  line within three  3  feet of any outlet of engine or generator exhaust systems  nor in a compartment housing an  engine or generator  nor in a bilge  unless the drain is connected properly to a sealed condensate or shower  sump pump     Installation and servicing of this system can be hazardous due to system pressure and electrical components  When  working on this equipment  always observe precautions described in the literature 
56. ver a period of time due to marine growth or scale build up  This both obstructs water flow  and prohibits proper heat transfer  To clean coils  using a chemical pump  flush with    5  muriatic or hydrochloric acid  and fresh water solution  Disconnect system hoses and check for fouling  Pump solution through coil  and hoses if  need be  until clean  Rinse with fresh water and reconnect hoses  Follow manufacturer s safety guidelines for all  cleaning solutions     Return Air Filters  Check the return air filter about once a month and clean as necessary  To clean the filter  remove it from the unit  rinse  with water  air dry and reinstall     Winterization  There are several methods of winterization  some of which work better than others  The four various methods em   ployed using a 50 50 non polluting biodegradable anti freeze water solution are     1  Pumping of anti freeze solution into the overboard thru hull fitting  and discharging through the intake thru hull  fitting  if the boat is out of water  If the boat is in the water then the thru hull should be closed and the system  drained then filled back to the unit outlet    2  Use of the seawater pump to pump anti freeze solution through the system and discharging through the  overboard thru hull fitting  Close seacock  remove hose from strainer discharge  raise hose above pump  so  pump does not lose its prime  and pour in anti freeze solution  Pump solution through system  The strainer and  hose to seacock will also ne
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Metra Electronics 95-3305 User's Manual  WNRT-627 User Manual_v1.0 - PLANET Technology Corporation.  COBEMAIL - Tools for COBOL Programmers  Optional One Man Installation KitS  «Quatrevingt-treize et le "Journal de Barbier"»  User Manual - iReasoning    Ciencia y Sociedad 4-10.pmd - Instituto Tecnológico de Santo  Manuel d`installation et d`utilisation  Groov-e GV-EB3-RD    Copyright © All rights reserved. 
   Failed to retrieve file