TAGMASTER INSTALLATION AND MAINTENANCE

image

Contents

1. ccceeeeeeeeetteeeeees 22 Annual Periodic Inspection 22 Trouble Shooting s icaccacandadkdadadddccedadadcdodadadadodadadscad 22 Contacts within Technical Support and Tagmaeier 24 Part Number 667 HE 46655 000 Issue 2 Page 2 of 24 Related Documentation Document Number Title 667 DZ 46655 000 VSD Tagmaster Family Tree 667 LP 46655 000 ETC Tagmaster Illustrated Parts List Installation and Commissioning Handbook Installation Ge Testing General 667 PA 46655 000 Tagmaster Global Support Plan 667 HQ 46655 000 Tagmaster Quick Start Guide 667 SD 46655 000 Tagmaster Test Specification Doc no 06 118 06 Tagmaster Gen 4 User Manual 1 Introduction 1 1 Purpose and scope This handbook gives details on the Installation Commissioning and Maintenance for the Tagmaster Selective Vehicle Detector system The handbook does not detail the interface or connection details to a supervising computer system The Tagmaster product in composed of two constituent elements e Reader e Tags The make up and configurations of these two constituent elements is dependent upon the system use The configuration and make up is described in the appropriate section according to their relevance to associated activity This handbooks detail the following e Basic overview of the Tagmaster hardware at module level at a level necessary for installation commissioning and maintenance Installation Procedure Commiss
2. as that would affect the sealing Specifications Figure 5 Reception Lobe TMO00103 4 3 Cable Installation 4 3 1 Cable Installation General In a standard Tagmaster installation two connections will be established one between Barrier Traffic HO output signal to the controller circuit and one to between power supply and reader In addition it is strongly advised that a LAN connection to a ground level enclosure is also established between reader and a remote position This will allow remote configurations and updates to be carried out following installation removing the requirement to work at height and the necessity for access arrangements Cables are not supplied with the LR series All cables must be shielded and suitable for the installation environment for instance at outdoor environment Use flexible cables with stranded wire The terminal blocks used are Phoenix type PT 1 5 which allow for a 6 core cable cross sectional area 1 5 mm Stranded wires must be fitted with a ferrule before being inserted in the termination blocks The cable for the RS485 interface must be a twisted pair cable and conform to the EIA RS485 standard A category 5 CAT5e cable is required for the Ethernet connection Part Number 667 HE 46655 000 Issue 2 Page 12 of 24 4 3 2 Reader Cable Connections The reader is provided with knock outs for incoming cables on both the horizontal and vertical edges First and foremost use the cable entries on the
3. C Sealing IP 65 Description Specification Size LR 6 290 x 165 x 56 mm Power Cable Entry Fitting 8 cable entry fitting holes diameter 16mm LR 6 Weight LR 6 0 95kg Part Number 667 HE 46655 000 Issue 2 Page 8 of 24 Material plastic Part Number 667 HE 46655 000 Issue 2 Page 9 of 24 4 Installation This section describes the procedure of installing the reader and tags including mounting the reader installing the necessary cables installing the power supply and performing a commissioning Installation engineers are advised to read through this entire section before performing installations 4 1 General Requirement To provide an example of a typical Siemens Tamaster installation the following requirements and installation sequence has been compiled to provide Installation Engineers with a basic reference for site surveys and installations Please note this sequence is provided as a guide modification and enhancement of this process will be carried out based on the actual installation requirements and the site survey 4 1 1 Site Survey During the Presale Tender phase of a prospective installation a site survey to ascertain the optimum locations for readers cable runs and power supply will be carried The type of ID tags to be used will be specified during a project planning phase based on considerations of communication distances and movement speeds 4 1 2 Typical Installation Equipmen
4. for power supply connection Pin Signal Description 1 SPL Positive DC Supply Input 2 RTN SPL Negative DC Supply Input 3 SPL Positive DC Supply Input Internally Connected to Pin 1 4 RTN SPL Positive DC Supply Input Internally Connected to Pin 2 4 3 2 4 External Tamper Switch Group J32 To protect the Reader from tampering there are two mechanical tampering switches which break if the cover is opened One tamper switch is connected internally to the controller board and will generate a software alarm when broken and the other is an external tamper switch interface which can be connected to an external alarm loop Pin Signal Description 1 TAMP A When the tamper switch is open TAMP A and TAMP B 2 TAMP B are connected 4 3 2 5 RS485 Serial Communications Interface Group J41 The controller board has one RS485 serial interface for both 2 wire and 4 wire communication RS485 supports multi drop serial networks The communication can be in both full duplex 4 wire and half duplex 2 wire Note If the installation requires long cables or high data speeds it may be necessary to use termination Pin Signal Description 1 TX Transmitted and received data to and from HOST 2 Tx 3 GND Ground 4 RX Received Data to Reader from HOST Part Number 667 HE 46655 000 Issue 2 Page 16 of 24 5 Rx Pin Signal Descriptio
5. is provided for Ethernet connection The clip for detaching the cable faces upwards from the controller board surface to allow mid board mounts The Ethernet connector has eight pins and the wire scheme is based on the T568A standard The pins are wired straight through the cable that is pins 1 through 8 on one end are connected to pins 1 through 8 on the other end Note The RJ45 connector will not pass through the cable gland Pass the Ethernet cable through the cable gland before crimping the connector on the cable 4 3 2 11 USB HOST Connector P2 USB devices are connected using a standard USB type A connector 4 3 2 12 Micro SD Memory Card Interface Socket P3 A standard micro SD memory card socket is used The card socket is placed on the underside of the controller board Part Number 667 HE 46655 000 Issue 2 Page 18 of 24 4 3 3 Cable from Pole Top Termination to Remote Enclosure Prior to installation a site survey will be carried out This site survey will reveal cable runs termination strategy and power supply enclosure locations The following information assumes that the reader is to be installed on a standard traffic signal pole A standard Tagmaster installation requires two core to provide power from a remote enclosure to the pole Top Cap assembly terminations A core pair is also required to return the barrier traffic signal activation signal from the reader to the barrier traffic controller Screened four core detector c
6. is typically present in the kHz and low MHz frequency band The LR series is using 2 45 GHz frequencies so typical industrial noise will not affect the communication Part Number 667 HE 46655 000 Issue 2 Page 7 of 24 2 3 2 Electromagnetic Interference in cables By using specified cables proper shielding and grounding as well as selecting a suitable communication interface optimum communication reliability is ensured 2 3 3 Lightning In order to protect the reader from possible effects of lightning additional surge protection on the inputs and outputs may be required 2 3 4 Temperature For most applications normal atmospheric cooling is sufficient for the reader However if heat is generated close to the reader the use of forced cooling or heat shields should be considered 3 Technical Data The table immediately below details the technical specification LR 3 series details provided for reference Description Specification Reading Range LR 6 0 6m Reading Range LR 3 0 5m Power Supply 10 to 30 VDC Power Consumption 4 5 W Current Consumption 175 350 mA 24 12 VDC Radio Frequency Range CW 2436 1 2464 1 MHZ Channel 5 97 FHSS 2400 2483 5 Mhz Tag Data Speed Low 4 kbps and high 16 kbps Ethernet 10 100 Mbps Serial Output RS232 2 wire or 4 wire RS485 Up to 115 2 kbps Description Specification Operating Temperature Range 30 C to 60
7. C Power Supply Voltage Check at Reader Read activation and Reception Lobe area check Relay activation check Down load of Authorised Tag list to memory stick Reader and remote enclosure termination check General installation deterioration check Review of tag requirements 6 3 Trouble Shooting The following table describes the most common problems encountered during installation as well as adequate solutions Three system status indicators on the controller board inside the Reader show the status of the unit as illustrated in Figure 2 The table below explains the different indicator meanings Part Number 667 HE 46655 000 Issue 2 Page 22 of 24 Colour Mode Indications Yellow On Power On Off Power Off Green Flashing System SW running Initially On System SW loading Persistently On System SW running Off System SW fault Red Flashing Quickly HW initiated and running On Initiation process Off HW not initiated The link state indicator and the activity indicator on the Ethernet connector inside the Reader show the status of the network communication as explained in the table below Colour Mode Indications Green On 100 Mbps Connection Off 10 Mbps Connection Yellow Flashing Present Communications On Link Exists Off No Communications The following table describes the most common problems encountered during installation and proposed solutions Problem Sol
8. Siemens Mobility Traffic Solutions Sopers Lane Poole Dorset BH17 7ER United Kingdom 44 0 1202 782000 http www siemenstraffic com Installation Commissioning and Maintenance Handbook for the Tagmaster Selective Vehicle Detection System Siemens plc 2015 All rights reserved The information contained herein is the property of Siemens plc and is supplied without liability for errors or omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied The names of products of third parties named in this document may be trademarks of their respective owners Document Authorisation Role Name sd Function _ Prepared by Stephen Thorpe Project Support Engineer Reviewed by Mike Tonkin Product Support Manager Authorised by Colin Whipps Technical Support Manager Signed Document Record Issue Number Date _ Comments Revision Details 001 Aug 2013 First Issue 002 Mar 2015 Update part numbers Part Number 667 HE 46655 000 Issue 2 Page 1 of 24 Contents NT OCUUICUIO Net ei ake ete eee aR ete te tee 3 Purpose andi Scopen ranan A a a a a a 3 System OvervieW sssssssssssiriissssssiitttt testtir cca aaee settee ttecaaaeeeeeeeeetneccaaaeeeeeeeeseeeeaaaes 4 Reader Overvieuw cece ee eeeeceaeeeeee
9. able can be used to carry out this function If four spare cores are available these can be utilized for this function however they should be labeled as designated for Tagmaster use The relay output from the Tagmaster reader and the power supply to the reader should be made available on a Standard termination terminal strip at the remote enclosure Note an addition terminal strip may be required for to carry out this termination A 22mm gland will be installed on the pole to allow the cable from the Tagmaster reader to pass through the pole and be terminated at the Top Cap assembly terminals There is often a requirement to update tags that are authorised to activate the Tagmaster reader In order to make this process as efficient as possible it is strongly advised that a LAN cable from the reader s LAN port is routed back to the remote enclosure housing the power supply or other remote position The LAN cable will be CAT 5e cable terminated with RG45 connectors This cable will be routed directly from the reader to the remote enclosure via the pole gland but without passing through pole Top Cap assembly terminals 4 4 Power Supply Installation The tagmaster reader s power supply will be housed in a remote enclosure The part number for the appropriate power supply should be sought from the illustrated parts catalogue detailed in the document reference section Mains power for the power supply will be taken from the enclosure auxili
10. ary fuse and output power DC supply made available at a terminal strip adjacent to the reader s supply cable Figure 9 Tagmaster reader power supply Part Number 667 HE 46655 000 Issue 2 Page 19 of 24 5 Commissioning and System Verification 5 1 General requirements After completing the installation as described in previous sections carry out the Commissioning and System Verification Procedure To carry out the commissioning the In Commissioning Engineer should be equipment with the following items e Two reference tags used on the commissioned system e Voltmeter e Laptop Computer e Tagmaster LR Series User Manual e Tools set as detailed for installation Ensure e there are no metal objects between or close to the reader e the cables reader and termination have not been disturbed since the installation procedure was carried out 5 2 Power Up and Voltage Check Note the following procedure should only be carried out by trained and qualified personnel Gain access to the remote enclosure housing the reader s power supply Ensure mains power is to the power supply is isolated and disconnect the output terminals Switch on the auxiliary main power Measure the output voltage from the reader s power supply Ensure that the output voltage is within the required ranges as stated in the Technical Specification section Switch off the mains power to the reader s power supply and reconnect the output cores to the reader Swi
11. e maintenance periodicity tools and other support requirement such as spare support please refer to the Tagmaster Global Support Plan detailed in the document reference section This maintenance section describes the maintenance procedures for the reader and how to solve the most common problems encountered during installation or in service Repair support is subject to individual support contracts however in general first line repair support for customers is achieved by phone support via the Siemens Contact Centre Second line support to customers will be provided by Field Service attending site For third line support Field Service will be supported from Siemens Mobility Traffic Solutions Head Quarters please refer to section 7 for contact details Reader repair will be achieved by full reader swop out With reference to the Tagmaster Gen 4 User Manual authorized Tag lists should be maintained independent of the reader to ensure that this activity can be carried out without loss of data Please note Individual components with the reader are not designed to be replaced at the installation site Please note any such unauthorized alterations to the reader will invalidate the warranty 6 2 Annual Periodic Inspection The following activities will be carried out at the annual period inspection Please refer to Appendix 1 for check list Main Supply Voltage check Tagmaster VDC Power supply Voltage check at Power Supply Output Tagmaster VD
12. eeeeeeeaaaeeeeeeeeegeecaaaaeeeeeeeeteeeesaeeeeees 4 Tag OVO EE 7 Environmental Considerations eeeeeeeeeeeeeeeeeeriirrrrttssterrrnrttssstrnrnnnnsesssennnn H Electromagnetic Interference ccceeecceeeee cette reece ease eee e ee eeceaaaeeeeeeeeetecaaeeeeeeeeenees 7 Electromagnetic Interference in cables cccccecceeeeeeeeeeeeeeeeeeeeeeeeeeeteccaeeeeeeeeeenees 8 Bisi DEEN 8 Re E IC 8 RK elle BEE 8 lee UE o TWEET 10 General Heouirement cece eeeceneeee eee eeeeeccaaaeeeeeeeeeegecaaaeeeeeeeeseeeeaaaes 10 SILO PS HEET 10 Typical Installation Equipment Imventorn 10 Ree 10 Mounting the Header 11 Orientating the Header 12 Cable Installaatio Hiran nanamin e e e 12 Cable Installation Genera 12 Reader Cable Connections sssssssssreesssesssrrrntsssettennntsssesnnnnnntsasetnrennnntssennennnnne 13 Cable from Pole Top Termination to Remote Enclosure ccccccccccccccceceeeeeeeeeeeees 19 Power Supply Installation se Siouan diaa ra aAA A iaaa 19 Commissioning and System Verification cc ccccceeeeeeeeeeeneeeeeeeeeeeeeccaeeeeeeeeeeeeenaaaes 20 General reouirements cece cece eeeeenceee eee eee eteceaaaeee sees eeteecaaaeeeeeeeeeneeeaaaes 20 Power Up and Voltage Check 20 Programming reference tags cccccceeececeee cece ee eeeeecaaeeeeeeeeeteeeaaaeeeeeeeeeeeeenaaaes 20 Reader Orientation and altgnment 21 Ee RE EE 21 Elte 22 General maintenance philosophy and introduction
13. ens com 8 Appendix 1 Periodic Inspection Check Sheet Check Activity Completion Status and Date Number 1 Main Supply Voltage check 2 Tagmaster VDC Power supply Voltage check at Power Supply Output 3 Tagmaster VDC Power Supply Voltage Check at Reader 4 Read activation and Reception Lobe area check Relay activation check Down load of Authorised Tag list to memory stick 7 Reader and remote enclosure termination check General installation deterioration check Review of tag requirements 10 Tagmaster VDC Power supply Voltage check at Power Supply Output Part Number 667 HE 46655 000 Issue 2 Page 24 of 24
14. gnal pole With reference to figures 3 and 4 mount the reader to the pole using a universal mounting bracket A slotted plate secures to the rear of the reader A trapezium shaped plate on the universal bracket slides into the slotted plate and is secured by two grub screw The universal bracket is secured to the pole by either utilizing the existing holes in the bracket and securing directly to the pole or modifying the bracket so that a pole mounting kit can be used Figure 3 Trapezium Plate Figure 4 M4 securing holes for holding rear plate to reader TM001 04 Where possible mount the reader in a horizontal position In exceptional cases the reader can be mounted in a vertical position Part Number 667 HE 46655 000 Issue 2 Page 11 of 24 4 2 1 Orientating the Reader Successful reception of a tag signal as a vehicle approaches a barrier or traffic junction relies on the tag entering the reception lobe of the reader With reference to figure 5 the reception lobe protrudes forward from the reader in a tear drop shape 14metres for LR6 XL reader and 10metres for the LR6 reader At initial installation the reader should be orientated so that the centre of the lobe points in the general direction of the required reception direction Mounting holes are sealed at the base so the fixing screw must not extend more than 8 mm into the reader Note Do not drill any additional holes in the enclosure
15. horizontal edge of the reader even if the reader is mounted in a vertical position Note The reader is certified for an installation of maximum four separate incoming cables Do not exceed this maximum number 1 Use a short 16 mm diameter tube to remove the desired knock outs Using a hammer as illustrated in Figure 6 tap the tube sharply Figure 6 TMO0106 Open the Reader using a Torx screwdriver Insert metal cable glands into the holes gland provided with the reader Cut the power cable to a suitable length and pull it through the cable gland Connect the shield of the power cable to earth at the power supply end The shield functions as earth connection for the Reader Measure enough length of the cable to reach to the pole termination block predetermined termination block or remote power supply 7 Strip the outer insulation and pull back the cable until the cable shield makes contact with the earthing fingers inside the gland 8 Tighten the cable gland around the cable ee lea D Part Number 667 HE 46655 000 Issue 2 Page 13 of 24 Figure 7 EE se ee TM00108 9 Cut away excessive length of the cable shield strip the ends of the conductors and crimp a ferrule onto the stripped end of each conductor 10 Connect the power cable to group J31 according to connection scheme detailed below 11 Make sure that the power source is turned off and connect the other end of the power cable to the power so
16. ioning Procedure Routine maintenance inspection procedures Tagmaster faults Hardware configuration An illustration of the reader and a listed breakdown of the reader in particular the component parts is provided in section 2 Please note it is important to check the contents of the shipment for completeness and possible damage If the contents are damaged report the circumstances immediately with the carrier and the Tagmaster sales or service organization contact details provide in section 6 Returns for repair should be carried via the standard Siemens Mobility Traffic Solutions Returns Process Part Number 667 HE 46655 000 Issue 2 Page 3 of 24 2 System Overview The two main elements of a Tagmaster identification system are the Reader and the ID tags The system can be augmented by elements such as a host controlling computer system The system is designed to control external devices such as traffic lights and barriers Figure 1 TM00102 The figure above shows the overview of a Tagmaster identification system with a pole mounted Reader an ID tag mounted on the inside of a car windscreen a host computer a power supply and a barrier 2 1 Reader Overview The LR series Tagmaster readers are devices for reading ID tags using 2 45 GHz frequencies In addition to reading tags some readers also have the capability to write information to tags The reader has built in antennas for communication with ID tags as well as variou
17. n 1 TX Transmitted and received data to and from HOST 2 Tx 3 GND Ground 4 NC Not Used 5 NC 4 3 2 6 RS232 Serial Communications Interface Group J42 The controller board has one RS232 serial interface Pin Signal Description 1 TX Transmitted Data from Reader to HOST RX Received Data to Reader from HOST GND Ground 4 3 2 7 Service Interface Group J43 The service interface is used for maintenance and configuration of the Reader Do not use the service interface as a regular system interface Pin Signal Description 1 TX Transmitted Data from Reader to HOST RX Received Data to Reader from HOST GND Ground 4 3 2 8 Isolated Input Group J51 The Reader has three isolated optocoupler inputs which are protected from noisy environments Pin Signal Description 1 IN1A Input Signal 1 2 IN 1C Input Reference 1 3 IN 2A Input Signal 2 4 IN 2C Input Reference 2 5 IN 3A Input Signal 3 6 IN 3C Input Reference 3 Part Number 667 HE 46655 000 Issue 2 Page 17 of 24 4 3 2 9 Isolated Output Group J52 The reader has two collector outputs Pin Signal Description 1 IN 1A Input Signal 1 2 IN 1C Input Reference 1 3 IN 2A Input Signal 2 4 IN 2C Input Reference 2 5 IN 3A Input Signal 3 6 IN 3C Input Reference 3 4 3 2 10 Ethernet Connection P1 An RJ45 connector labeled P1 with two internal indicators
18. onfiguration with a wide range of input and output devices including relays isolated I O indicators and a buzzer The Reader has several communication alternatives and is easily integrated using the following communication interfaces Ethernet RS232 RS485 USB Host Wiegand Mag stripe Micro SD memory card Note the Readers can be configured with varying levels of application software The application software loaded may not be designed to support the use of these interfaces consult corresponding software manual for further information Part Number 667 HE 46655 000 Issue 2 Page 5 of 24 Reader Components please refer to figure 2 1 Lid 2 Controller board 3 RF unit 4 Externally visible indicators 5 Tamper switches 6 Red system status indicator 7 Green system status indicator 8 Yellow system status indicator 9 TX unit 10 Enclosure base 11 Chassis 12 Knock out for cable entry 13 Terminal blocks 14 Ground screw 15 Ethernet connector with link state and activity indicators 16 Micro SD slot 17 USB host connector intended for internal expansion 18 Pressure balance membrane Figure 2 5 10 11 18 Part Number 667 HE 46655 000 Issue 2 Page 6 of 24 2 2 Tag Overview An ID tag is a device configured with ID information that can be read at a distance by the reader The reading range depends on the type of the reader the ID tag the settings of the reader and environmental conditions ID tags vary slightly in
19. ried out by two engineers One engineer will make the physical adjustment to the reader while the second presents the reference tag to the reader An indication that a tag has been read will be a red or green LED illuminated on the front of the reader red for unauthorised and green for authorized activation Figure 10 Monitor the relay output connection and ensure that the output signal is activated when an authorised tag is presented Program the appropriate number of tags for the end users needs Secure the front of the reader and all enclosures Connect the relay activation connections at the remote enclosure to the output circuit and ensure that the barrier traffic signal is activated 5 5 Tag Installation As detailed in the general introduction Siemens advocate the use of three type of Tagmaster reader activation Tag Each of the three types of Tag can be supplier with Tag holders Please refer the Tagmaster Illustrated Parts Catalogue detailed in the document reference section The make model and configuration of vehicle into which Tags will be installed will vary The general requirement when positioning a tag within a vehicle is to ensure that the tag is presented to the reader line of sight to the reader Please refer to figure 11 for tag example location Figure 11 Part Number 667 HE 46655 000 Issue 2 Page 21 of 24 6 Maintenance 6 1 General maintenance philosophy and introduction For full information on th
20. s serial interfaces for communication with a host computer The Tagmaster reader is the system s primary component The system is produced in Sweden by Tagmaster Tagmaster manufacture configure and distribute a series of readers of varying complexity The two variant of Tagmaster reader provided for installation and subsequent support by Siemens are Product Name Detection Range Siemens Part Number LR 6 10m 667 9 99400 010 LR 6 XL 14m 667 9 99400 014 As indicated the primary difference between these two readers is the read range of the tags with a nominal range of 10 metres and 14 meters respectively Part Number 667 HE 46655 000 Issue 2 Page 4 of 24 The Readers are designed for above ground installation In most instances the Reader will be mounted to an existing standard 4 metre traffic pole However a Universal Pole Mounting Kit will allow fitting on poles between 70mm and 140mm diameter Power input and relay activation output signal can be made using a single 4 core cable this allows the use of a single cable entry to provide these functions To allow updates and reader diagnostics to be carried efficiently following installation it is advisable to provide a remote connection to the Reader s Ethernet port An Ethernet cable can be run to a suitable enclosure where the associated Tagmaster power supply may also be housed The reader is powered with a voltage ranging from 10 to 30 V DC The LR series reader is designed for c
21. size and shape but all are of a compact designed suitable for mounting discretely within a vehicle Each ID tag has its own unique number and it is possible to read many ID tags concurrently A lithium battery is used in the ID tag to achieve a high communication speed and a long reading range Siemens advocate the use of three types of tags MarkTag MaxType Tamper Evident Tag MarkTag Classic Credit Card Tag and the MarkTag Memory Tag Please refer to the illustrated Parts Catalogue detailed in the document reference section Reader set up is detailed in the commissioning section but fundamentally maximum communication range is achieved when the front surface of the ID tag is parallel with the front side of the reader If the ID tag is misaligned relative to the front side of the reader the communication range will be reduced Figure 3 Example Tag The Tagmaster Classic 290mm gt 55mm Product Name Siemens Part Number MarkTag Classic Credit Card Tag 667 9 99401 000 2 3 Environmental Considerations The LR series reader is a device for reading ID tags using 2 45 GHz frequencies In addition to reading some readers also have the capability to write information to ScriptTags see separate data sheet for specific capabilities of the reader The reader has built in antennas for communication with ID tags as well as various serial Interfaces for communication with a host computer 2 3 1 Electromagnetic Interference Industrial noise
22. t Inventory Please consult the illustrated part catalogue detailed in the document reference section for details of individual parts as indicated below Those parts not detailed in the illustrated parts catalogue are detailed here Please note reference to the site survey and project plan should be made before a full parts inventory associated with site installations is compiled e Tagmaster readers illustrated parts catalogue Universal Brackets illustrated parts catalogue Reader to Pole Top Cap assembly connection cable Cat 5e cable RS Components part number 103 499 or similar and possibly from alternative supplier 4 core 2 pair screened cable Siemens Part Number 998 4 85263 001 Power supply illustrated parts catalogue Cabinet Terminal Strip Siemens Part Number 667 1 04099 000 Tagmaster Test Tag illustrated parts catalogue 22mm pole gland RS Components part number 669 4689 or from alternative supplier 4 1 3 Tools The following tools are necessary for installation Screwdriver Torx T20 Screwdriver 2 5 mm flat bladed Tamtorque Tool TTBP50BG RS 365 2395 Short metal tube diameter 16 mm knocking out reader cable blanks Hammer Side cutter Wire stripper RG45 stripping tool RG45 Crimping tool Standard Engineer s tool kit Part Number 667 HE 46655 000 Issue 2 Page 10 of 24 e Drill and drill bit installation of 22mm pole gland 4 2 Mounting the Reader The reader will typically be installed on a traffic si
23. tch on the power supply and measure the output power supply to the reader Ensure that the output voltage remains within the required tolerances Gain access to the reader and open the tagmaster reader s lid Measure the power supply voltage at the input terminals of the reader Ensure that the voltage level is within the required tolerances 5 3 Programming reference tags With reference to the Tagmaster Gen 4 User Manual see document reference section connect a laptop computer to the Tagmaster reader and with the read tag radio button checked present the two reference tags to the Tagmaster reader Transfer the two tag ID s to the authorised ID list and save the reader s settings With further reference to the GEN 4 Tagmaster user manual and using the appropriate menu configure the reader to provide a visual indication when a tag is presented to the reader Part Number 667 HE 46655 000 Issue 2 Page 20 of 24 5 4 Reader Orientation and alignment With reference to figure 5 in order that the reader can detect the presence of an authorised tag at the appropriate range and in the correct area the reception lobe direction should be optimized Using the adjustment screws on the universal mounting bracket adjust the reader to point in the direction required for optimum reception of the reception lobe The reader s lid which houses the reader s antenna should be close while this activity is carried out This activity most efficiently car
24. urce Part Number 667 HE 46655 000 Issue 2 Page 14 of 24 12 Connect the relay activation cables in the same manner The Ethernet cable will be plugged into Ethernet Connector P1 Figure 8 123 123456123 J1 J51 J5 451234121234 12 2 J31 J32 J2 J 45123 123 1 J42 J43 TM00107 Note It is possible to attach or remove the terminal block connectors inside the reader for more convenient connection of the cables The terminals are grouped as specified as below 4 3 2 1 Relay Output Group J1 The controller board has one relay output for heavy duty loads Pin Signal Description 1 RCOM Common Terminal or Relay ROPEN Connected to RCOM when relay is open RCLOSE Connected to RCOM when relay is closed 4 3 2 2 Wiegand Mag Stripe J2 The controller board has an access control interface that supports both Wiegand and Mag stripe protocols Pin Signal Description 1 DO Wiegand 1 Signal 2 D1 Wiegand Signal 3 CL Card Load Signal 4 GND Ground Part Number 667 HE 46655 000 Issue 2 Page 15 of 24 Pin Signal Description 1 CLK Mag Strip Clock Signal 2 DATA Mag Strip Data Signal 3 LOAD Card Load Signal 4 GND Ground 4 3 2 3 Power Supply Group J31 Pin 1 is internally connected to pin 3 and pin 2 is internally connected to pin 4 The purpose is to make it possible to feed power to any peripheral equipment Use pins 1 and 2
25. ution Yellow system status indicators is off Check the power supply Green system status indicators is on or off Switch off the power supply switch it on again and wait 30 seconds This can be done by pulling the J31 terminal block off the board and putting it back again If the Reader fails to start again contact TagMaster support Red system status indicator is off Switch off the power supply and switch it on again This can be done by pulling the J31 terminal block off the board and putting it back again If the Reader fails to start again contact TagMaster support Part Number 667 HE 46655 000 Issue 2 Page 23 of 24 Yellow Ethernet indicator is Check the network connection off 7 Contacts within Technical Support and Taqmaster For any support related questions queries or problems please contact the Technical Support Department Siemens Mobility Traffic Solutions Sopers Lane Poole BH17 1ER Departmental contacts are as follow Mike Tonkin Trish Walker Colin Whipps TagMaster AB Web www tagmaster com TagMaster AB Kronborgsgrand 1 S 164 87 KISTA Sweden Phone 46 8 632 19 50 Fax 46 8 750 53 62 E mail sales taqgmaster com Project Support Manager 01202 782108 mike tonkin siemens com Product Support Engineer 01202 782825 patricia m walker siemens com Technical Support Manager 01202 782875 colin whipps siem