1. 10 ORDERING INFORMATION SCODION GBG Re eres aan ale asa os wee eat ins ne rs nent eee ee SCORPIONGBC WARRANTY INFORMATION MVEA ANALY A NA 2 year limited warranty Laser Diode Warranty veccsiscanestccanccanssa reota A aa aiai 90 day limited warranty Scorpion GBC User Manual 20 12 17 2009 10 50 AM
2. Caution Caution Scorpion GBC User Manual 4 12 17 2009 10 50 AM NON INTERLOCKED HOUSING WARNING This unit contains high power laser devices internally Do not open the laser housing due to potential exposure to unsafe levels of laser radiation The laser power levels accessible if the unit is opened can cause instant blindness skin burns and fires LASER SAFETY AND OPERATING INSTRUCTIONS Laser Light is different from any other light sources with which you may be familiar The light from this product can potentially cause eye injury if not set up and used properly Laser light is thousands of times more concentrated than light from any other kind of light source This concentration of light can cause instant eye injuries primarily by burning the retina the light sensitive portion at the back of the eye Even if you cannot feel heat from a laser beam it can still potentially injure or blind you or your audience Even very small amounts of laser light are potentially hazardous even at long distances Laser eye injuries can happen quicker than you can blink is incorrect to think that because these laser entertainment products split the laser into hundreds of beams that the laser beam is scanned out in high speed that an individual laser beam is safe for eye exposure This laser product uses dozens of milliwatts of laser power Class 3B levels internally before it splits into multiple beams Class 3R levels Man
3. GBC VOLTAGE 100 240 VAC 50 60 Hz THIS APPLIANCE MUST BE FUSE F 1 6 A 250 V GROUNDED CURRENT 0 3 A 115 V ue POWER 23 W USE ONLY FUSE OF SAME TYPE amp POWER LINKING MAX 414 W da RATING LIGHT SOURCE Laser ORIGIN Made in P R C DISCONNECT FROM MAINS BEFORE FA SERVICING MANUFACTURING DATE 2009 FOR INDOOR USE ONLY EXPLANATORY MANUFACTURER S ID 8 CERTIFICATION LABEL NON INTERLOCKED HOUSING LABEL LASER HAZARD WARNING LABEL LASER APERTURE LABEL Scorpion GBC User Manual 6 12 17 2009 10 50 AM LASER LIGHT AVOID DIRECT EYE EXPOSURE Further guidelines and safety programs for safe use of lasers can be found in the ANSI 2136 1 Standard For 5816 Use of Lasers available from the Laser Institute of America www laserinstitute org Many local governments corporations agencies military and others require all lasers to be used under the guidelines of ANSI 2136 1 Laser Display guidance can be obtained via the International Laser Display Association www laserist org LASER EMISSION DATA CLASS 3R EQUIV TO US CLASS IIIA DPSS Nd YVO4 532 nm 473 nm typical lt 5 mm at aperture All pulses lt 4 Hz gt 0 25 sec lt 2 mrad lt 160 degrees lt 5 mW LASER CLASSIFICATION Green Laser Medium Blue Laser Medium Beam Diameter Pulse Data Divergence each beam Divergence total light Laser Power of Each Beam from Aperture As measured under IEC measurement conditions
4. When a menu function is selected the display will show immediately the first available option for the selected menu function To select 8 menu item press Use lt UP gt and lt DOWN to navigate the menu map and menu options Press lt ENT gt to access the menu function currently displayed or to enable a menu option To return to the previous option or menu without changing the value press lt MODE gt DMX Operation This is the operating mode which will allow for control with an external DMX controller You must set the starting address for this mode If this is your first time using DMX then it is recommended that you refer to the DMX Primer section in the Appendix of this manual When operating in DMX receiving mode the display will blink at a constant rate in the absence of DMX signal Use the following procedure for setting the fixture to DMX operation 1 Press lt MODE gt repeatedly until a number from 001 512 appears on the LED display 2 Use lt UP gt and lt DOWN to select the DMX starting address 3 Press lt ENT gt Scorpion GBC User Manual 13 12 17 2009 10 50 AM Standalone Operation Automatic This fixture has preprogrammed automatic programs These are accessed via the LED display on the back panel of the product Please see the instructions below for further explanation 1 Press lt MODE gt until a standalone mode appears on the LED display See the chart under menu functions
5. for classification LASER COMPLIANCE STATEMENT This laser product complies with EN IEC 60825 1 Ed 2 2007 03 and US FDA CDRH FLPPS via the terms of Laser Notice No 50 dated June 24 2007 This laser device is Classified 3R Class 3R is the international equivalent of US Class Illa No maintenance is required to keep this product in compliance with laser performance standards 12 17 2009 10 50 AM Scorpion GBC User Manual 7 2 INTRODUCTION Features 10 channel DMX 512 controlled green blue amp cyan aerial effect laser Programmable pan tilt and zoom with separate X Y and Z rolling effects 32 built in pattern selections each with adjustable parameters Color selection of green blue and or cyan with strobe control Built in automatic programs via master slave or DMX Built in sound activated programs via master slave or DMX Additional Features e Complies with FDA CDRH standards for Class 3R gt Multiple mounting locations for bracket e Additional power output max 20 units DMX Channel Summary CHANNEL FUNCTION 1 Control Mode 2 Pattern Selection 3 Color selection 4 Color Changing Speed 5 Zoom 6 X Axis Move Pan 7 Y Axis Move Tilt 8 Y Axis Roll 9 X Axis Roll 10 Z Axis Rotate Scorpion GBC User Manual 8 12 17 2009 10 50 AM Product Overview Back Panel View SOUND CONTROL MODE UP DOWN ENT Hanging bracket Laser Aperture Bracket adjustment
6. instructions below for further explanation on how to set a fixture to slave mode 1 Press lt MODE gt until slave mode appears on the LED display See the chart under menu functions to identify this 2 Press lt ENT gt A fixture that is operating in one of the standalone mode will function as a master unit when the fixtures are linked using DMX cables in a daisy chain configuration Scorpion GBC User Manual 14 12 17 2009 10 50 AM Menu Functions MAIN FUNCTION SELECTION DESCRIPTION VALUES DMX mode 00 SA DMX starting address assignment RFS Automatic fast blue RSS Automatic slow blue REG Automatic fast green RSS Automatic slow green REC Automatic fast cyan Automatic slow cyan Automatic fast mixed Automatic slow mixed Standalone modes Sd Sound blue Sound green Sound cyan Sound mixed Random Laser sky blue LSS Laser sky green Laser sky cyan Laser sky Sound Slave Mode LR Slave mode Test Mode cSt Used for service purposes Scorpion GBC User Manual 15 12 17 2009 10 50 AM FUNCTION Control Mode Manual Mode Automatic fast blue Automatic slow blue Automatic fast green Automatic slow green Automatic fast cyan Automatic slow cyan Automatic Fast mixed Automatic Slow mixed Sound blue Sound green Sound cyan Sound mixed Random Auto Pattern selection only when CH1 is between 000 017 See the following page for channel values Color selection Bla
7. knob 1 of 2 Power LED Audio LED Scorpion GBC User Manual 9 12 17 2009 10 50 Product Dimensions 105 mm 4 1 in Scorpion GBC User Manual 10 12 17 2009 10 50 AM Proper Usage This fixture has been designed to be hung It is recommended for safety purposes your lighting effects are properly mounted using a suitable hanging clamp and safety cable Items appropriate for safe and effective mounting are easily sourced from your lighting vendor International laser safety regulations require that lasers must be operated in the fashion illustrated below with a minimum of 3 meters 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 3 meters of horizontal separation is required between laser light and audience or other public spaces 3 meters CAUTION Use of controls adjustments or performance of procedures other than what is specified herein may result in hazardous radiation exposure CAUTION Use of controls adjustments or performance of procedures other than what is specified herein mav result in hazardous radiation Scorpion GBC User Manual 11 12 17 2009 10 50 AM 3 SETUP Mounting Orientation This fixture may be mounted in any safe position provided there is adequate room for ventilation Hanging Clamp Rigging is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type cla
8. to identify these 2 Use lt UP gt and lt DOWN to scroll through the standalone modes 3 Press lt ENT gt when the desired automatic standalone mode has been located Sound Active This fixture has preprogrammed sound triggered programs These are accessed via the LED display on the back panel of the product The sound control adjustment knob may be used to adjust the microphone sensitivity Please see the instructions below for further explanation 1 Press lt MODE gt until a standalone mode appears on the LED display See the chart under menu functions to identify these 2 Use lt UP gt and lt DOWN to scroll through the standalone modes 3 Press lt ENT gt when the desired sound standalone mode has been located Laser Sky This fixture has preprogrammed laser sky programs These are accessed via the LED display on the back panel of the product Please see the instructions below for further explanation 1 Press lt MODE gt until a standalone mode appears on the LED display See the chart under menu functions to identify these 2 Use lt UP gt and lt DOWN to scroll through the standalone modes 3 Press lt ENT gt when the desired laser sky standalone mode has been located Master Slave Operation When operating more than one fixture in standalone mode it is possible to link them ina master slave configuration This is when one or more slave fixtures will operate identically to the master fixture Please see the
9. 2 Values Pattern Selection 1 CHAUVET 2009 All Rights Reserved Information and specifications in this User Manual are subject to change without notice CHAUVET assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual Scorpion GBC User Manual 1 BEFORE YOU BEGIN What is included 1 x Scorpion GBC 1 x Power cable 1 x Warranty Card 1 x User Manual Unpacking Instructions YYYY Immediately upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC Power This fixture has an auto ranging power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 100 240 VAC 50 60 Hz All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circui
10. Snapshot WITH FAT BEAM TECHNOLOGY Power Supply CHANEL 3000 N 29 Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 12 17 2009 10 50 TABLE CONTENTS BEFORE 00 ne eee ee UNPACKING INSTRUCTIONS AC nt SAFETY INSTRUCTIONS 07 NON INTERLOCKED HOUSING WARNING 2 LASER SAFETY AND OPERATING INSTRUCTIONS ire LASER EXPOSURE INTRODUCTION Sac en nn dt D A et CE ADDITIONAC FEATURE Sna DMX GHANNEL SUMMARY cn ah EE PRODUCT OVERVIEW Back Panel AO nenn PRODUIT IN SION 7 777 a Se Fower OPERATING INSTRUCTIONS wicca wailed ree ee NAVIGATING THE CONTROL an tete aa te di BMX OPERATION RSS a a nn Rd nt STANDALONE OPERATION un cu RS tas 8 en 0 MASTER SEAVE OP RATIONS E E EE EE E E anti MENU FUNCTIONS E A DIX CHANNEL VALUES cn naar ni nn ts a rs Channel
11. address For example a fixture that uses 6 DMX channels and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Choose start addresses so that the channels used do not overlap and note the start address selected for future reference this is your first time addressing a fixture using the DMX 512 control protocol we suggest jumping to the Appendix Section and reading the heading DMX Primer It contains very useful information that will help you understand its use Scorpion GBC User Manual 18 12 17 2009 10 50 AM General Troubleshooting Applies to on EE j en PSE Lights amp Snow Controllers amp Chaser Breaker Fuse keeps Check total load placed on device blowing Chase is too slow is too slow Check user manual for speed adjustment 4 has power Check for power Mains Check device s fuse internal and or external Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights No laser output Bounce mirror motor may have shifted during shipping v readjust If you still have a problem after trying the above solutions please contact CHAUVET Technical Support Contact Us World Wide General Information CHAUVET 3000 North 29 Court Hollywood FL 33020 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Suppor
12. ckout Preprogrammed Color Blue Green Cyan Alternate Blue Green Alternate Green Cyan Alternate Blue Cyan Alternate Blue Green Cyan Color Roll Color Changing Speed Stop Slow amp fast Zoom 1 00 5 Zoom In Macro Zoom Out Macro Zoom In and Out Macro X Axis Move Pan 128 different positions on Y Axis Move Left to right to Left Slow gt lt fast Move Left to right to Left Fast gt slow Y Axis Move Tilt 128 different positions on X Axis Move Up to down to Up Slow gt gt fast Move Up to down to Up Fast gt gt slow X Axis Roll 0 359 Y Axis Roll Roll Slow gt gt fast Roll Fast slow Y Axis Roll 0 359 Y Axis Roll Roll Slow gt gt fast Roll Fast slow Rotate 0 359 Z Axis Roll Clockwise Rotate Counterclockwise Rotate 16 12 17 2009 10 50 AM DMX Channel Values VALUE 000 255 000 127 128 gt gt 1 192 5 CHANNEL 10 Scorpion GBC User Manual Channel 2 Values Pattern Selection 000 007 064 071 128 135 190 197 008 015 072 079 54 136 143 198 205 016 023 A 080 087 144 151 206 213 SND mjaa 056 063 120 127 182 189 Scorpion GBC User Manual 17 12 17 2009 10 50 AM 222 229 230 237 0 0 0 5 Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Prod
13. d to damage or malfunction Please contact the nearest authorized technical assistance center Never connect the device to a dimmer pack Make sure the power cord is never crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source while it is on Lasers can be hazardous and have unique safety considerations Permanent eye injury and blindness is possible if lasers are used incorrectly Pay close attention to each safety REMARK and WARNING statement in the user manual Read all instructions carefully BEFORE operating this device Avoid direct eye contact with laser light Never intentionally expose your eyes or others to direct laser light This laser product can potentially cause instant eye injury or blindness if laser light directly strikes the eyes It is illegal and dangerous to shine this laser into audience areas where the audience or other personnel could get direct laser beams or bright reflections into their eyes It is a US Federal offense to shine any laser at aircraft Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact the dealer nearest to you Caution Caution Caution Caution
14. metal Even laser reflections can be hazardous Never point a laser at aircraft this is a federal offense Never point un terminated laser beams into the sky Do not expose the output optic aperture to cleaning chemicals Do not use laser if the laser appears to be emitting only one or two beams Do not use the laser if the housing is damaged open or if the optics appear damaged in any way Never open the laser housing The high laser power levels inside of the protective housing can start fires burn skin and will cause instant eye injury e Never leave this device running unattended The operation of a class 3R laser show is only allowed if the show is controlled by a skilled and well trained operator familiar with the data included in this manual The legal requirements for using laser entertainment products vary from country to country The user is responsible for the legal requirements at the location country of use Always use appropriate lighting safety cables when hanging lights and effects overhead Scorpion GBC User Manual 5 12 17 2009 10 50 AM LASER SAFETY LABEL REPRODUCTION vZOEE 14 62 N 000 Sulyysi LIANWHD Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No 50 dated June 24 2007 WORLDWIDE HEADQUARTERS CHAUVET HOLLYWOOD FLORIDA Value Innovation Performance USA NAME Scorpion
15. mp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs e When selecting installation location take into consideration Note access and routine maintenance Clamp is sold separately e Safety cables must always be used e Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation gt Do not use any tool on the bracket adjustment knob Hand tighten only Power Linking This fixture contains power linking via the edison outlet located in front of the power input cable Please see the diagram below for further explanation The maximum number of fixtures that may be linked for this fixture is 20 Additional power link Fixture 3 Fixture 2 Fixture 1 Scorpion GBC User Manual 12 12 17 2009 10 50 AM 4 OPERATING INSTRUCTIONS Navigating the Control Panel Access control panel functions using the four panel buttons located directly underneath the LED Display Button Function Used to access the menu or to return to a previous menu option Scrolls through menu options in ascending order Scrolls through menu options in descending order Used to select and store the current menu or option within a menu The Control Panel LED Display shows the menu items you select from the menu map
16. t even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Scorpion GBC User Manual 3 12 17 2009 10 50 AM Safety Instructions Please read these instructions carefully which includes important information about the installation usage and maintenance of this product Please keep this User Manual for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse size and rating Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 4050 Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lea
17. t CHAUVET 3000 North 29 Court Hollywood FL 33020 voice 954 929 1115 Press 4 fax 954 929 5560 Attention Service World Wide Web www chauvetlighting com Scorpion GBC User Manual 19 12 17 2009 10 50 AM Technical Specifications WEIGHT amp DIMENSIONS Rs ent de 11 3 in 287 mm 7 in 340 mm 13 4 FOR ne ne tente sites tienne 9 1 in 230 mm lbs 3 5 kg 7 8 0 POWER Auto ranging 100 240 VAC 50 60 Hz E Ne ae ne 1 5 250 V slow blow 120 0 23 W 0 3 A max 0 NV eh ceed rs ie dd na ind Lean ce dE 0 3 A POWER 230 VS en 20 W 0 2 A max BO en te nat 0 2 A 0 20 units max LASER Groon diod Ra ns ne 532 nm 30 mW 0 07 473 nm 40 mW ES TT TYPO DPSS Fan Cooled RANGE 53 THERMAL Maximum ambient temperature 7 4 104 F 4050 CONTROL amp PROGRAMMING Data locking 3 pin XLR male socket DA OUIDU ns anne nement locking 3 pin XLR female socket Data DIN COMMGUPANOM pin 1 shield pin 2 pin 3 PrOtOCOlS SRI A AEEA ni DMX 512 USITT
18. ucts returned without an RMA will be refused Call CHAUVET and request RMA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name Your address Your phone number The RMA A brief description of the symptoms Dee Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping Any other claim for items such as missing component part damage not related to shipping and concealed damage must be made within seven 7 days of receiving merchandise Setting the Starting Address This DMX mode enables the use of a universal DMX controller device Each fixture requires a start address from 1 to 512 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start
19. y of the individual beams are potentially hazardous to the eyes is also incorrect to assume that because the laser light is moving it is safe This is not true Nor do the laser beams always move Since eye injuries can occur instantly it is critical to prevent the possibility of any direct eye exposure In the laser safety regulation it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor 6 Do not operate the laser without first reading and understanding all safety and technical data in this manual Always set up and install all laser effects so that all laser light is at least 3 meters 9 8 feet above the floor on which people can stand See Proper Usage section later in this manual 9 After set up and prior public use test laser to ensure proper function Do not use if any defect is detected Do not use if laser emits only one or two laser beams rather than dozens hundreds as this could indicate damage to the diffraction grating optic and could allow emission of higher laser levels above Class 3R Do not point lasers at people or animals Never look into the laser aperture or laser beams Do not point lasers in areas in which people can potentially get exposed such as uncontrolled balconies etc Do not point lasers at highly reflective surfaces such as windows mirrors and shiny