1. 2 Identification The device can be identified by the label s data ordering code serial number This information is listed in the delivery document For technical features of the product to make reference at the technical catalogue 3 Installation Install the device according to the protection level provided Protect the system against knocks friction solvents and respect the environmental characteristics of the product 4 Mounting recommendations Push the display into the cut out approx 90 x 66 mm without panel clips Install panel clips on the display s housing and screw until fixed www lika it www lika biz PH SYSTEMS www phsystems be sales phsystems be lixa ees 5 Electrical connections 5 2 CON2 connections sensor input wis 1 23 45 6 7 8 9 10 ne GND Con2 24Vde J1 left power supply 24Vdc Gl 12Vdc J1 left power supply 115Vac 230Vac m gt m P al fo o Con3 Ore a z9 eee eT 0 see parameter P22 PLE 5 1 CON1 connections power supply PE Power supply 24Vde output power supply for measuring system ee USA 5 3 CON3 connections Inputs and Outputs Pin2 n c a Pin 4 GND 1 24Vde
2. code number here to prevent operator from entering the Parameter mode Level 2 Default value O Attention Datum value can be set only after digiting the correct password To cancel password and restore default value see chapter Default parameter 6 2 1 MAN MC150 ILE 1 7 12 MC150 PO7 Function of the push buttons 0 6 The function of the A and the E buttons in Operating mode can be selected 0 no functions 1 E will set actual value to zero 2 A will set actual value to Preset Funct POO 4 E activates Offset P12 8 gt will set absolute incremental mode 16 E will set Inch mm mode To combine more than one function add up the totals of the different functions and enter the sum amount 3 function 1 and 2 activated 6 function 2 and 4 activated 9 function 1 and 8 activated 11 function 1 2 and 8 activated 14 function 2 4 and 8 activated 18 function 2 and 16 activated PO8 Input 1 Reset function 0 1 Sets function of Reset input 0 static reset Sets actual value to O until input Is activated high 1 dynamic reset Edge triggered Reset input PO9 Encoder Index function 0 2 Sets function of encoder index pulse 0 0 0 no function 1 Rising edge triggered Index pulse 2 Falling edge triggered Index pulse P10 Input2 SET function 0 1 Sets function of SET input O static SET input Sets display to Preset value until input is activated high 1
3. dynamic SET Edge triggered SET input P11 Input 3 Freeze Stop Absolute incremental function 0 2 Sets function of Freeze Stop input O freeze actual value while internal counter is still active 1 stop encoder pulse counting 2 change absolute incremental mode www lika it www lika biz PH SYSTEMS www phsystems be sales phsystems be lixa ees P12 Offset 0 65000 P17 Output 1 dwell time 0 2 50 Value entered here will be subtracted from actual Enter output dwell time between O and 2 50 value by activating OFFSET function Input 4 seconds P16 must be 1 By deactivating OFFSET input Offset value will be Default value O added to actual value Enter the Offset dimension in units of length such P18 Output 2 dwell time 0 2 50 as XX X MM or X Xx inches Enter output dwell time between O and 2 50 Default value 10 0 seconds P16 must be 1 Default value O P13 Function input configuration 0 15 Chose from NO Normally Open or NC Normally P19 Memory on power down 0 1 Closed low active connected with GND or high 0 actual value will be stored on power down active connected with 24Vdc 1 after turning power off and on Display shows Cal Display has to be Datumed again before CONS use see Func1 PO00 rab Jane GND 424Vde P20 Saw blade offset 10000 10000 ee 5 T T Here a value can be stored which is subtracted NC NO from the display value when the Set or Reset Me function
4. is activated in incremental mode 2 3 12 NO NO Default value O 4 11 NO NC NO P21 Output logic 0 3 6 9 NO NC NC NO Enter output logic of Output 1 and Output 2 7 8 nc nc nc NO 0 Output 1 activated when Actual value gt P14 8 7 NO NO NO NC Output 2 activated when Actual value gt P15 9 6 NC NO NO NC 1 Output 1 activated when Actual value lt P14 Output 2 activated when Actual value gt P15 11 4 NO NC 2 Output 1 activated when Actual value gt P14 Output 2 activated when Actual value lt P15 3 Output 1 activated when Actual value lt P14 14 1 NO NC NC NC Output 2 activated when Actual value lt P15 P22 Select CON2 input signals 0 1 P14 Output 1 99999 999999 0 measuring system with A B and Z tracks 1 measuring system with A A B B Z and Z tracks Output 1 will be activated when actual value is more or less than Output 1 value see P21 Default value 10 0 P15 Output 2 99999 999999 Output 2 will be activated when actual value is more or less than Output 1 value see P21 Default value 20 0 P16 Output configuration 0 1 0 static output 1 with output dwell time see P17 and P18 MAN MC150 I_E 1 7 13 www lika it www lika biz PH SYSTEMS www phsystems be sales phsystems be lixa Setup for devices with RS232 serial interface option 11 P60 Display address 11 99 Enter here the serial add
5. 00 19200 38400 Data bits 8 bit ASCII Parity bit Flow control No 8 3 Communication protocol The RS232 protocol is according to DIN 66019 ISO 1765 ANSI X3 28 The PC is the master and the MC150 is the slave with individual serial address to be entered in Parameter P60 There are 3 ways of communication e Send e Receive e Broadcast www lika it www lika biz PH SYSTEMS www phsystems be sales phsystems be o lixa 8 3 1 Protocol structure Level code 20 Level 1 21 Level 2 C3 C4 Parameter code 00 99 ascll DATA End of TeXt ascii Block Check Character ENQuiry 15 H Not Acknowledge 06 H Acknowledge NOTE e BCC block check character is a character used for check the correct transmission It is generated by XOR ing characters C1 C2 C3 C4 DATA and ETX including If BCC lt 20 Hex BCC must be added up with 20 Hex this avoids BCC to have values in the range of control character values e DATA field can contain any number of numerical characters a sign and can be filled up with zeros All DATA are sent in ASCII Code 8 3 2 Send data from Master to Slave PC gt MC150 EOT AD1 AD2 STX C1 C2 C3 C4 ETX BCC When transmission is correct slave replies with ACK in any other cases with NAK MC150 gt PC or _ Nak All parameters sent to the slave are stored in a data buffer Parameters have to be activated by the activate parameter command see chap
6. 8 3 4 MAN MC150 I_E 1 7 PH SYSTEMS www phsystems be MC150 Example Sets the parameter PO1 100 unit address 11 PC gt MC150 _ EoT AD1 AD2 stx C1 C2 c3 c4 asci 1 1 2 i1 o 71 DATA ERX BCC ascii 1 o o Hex 31 30 30 03 30 MC150 gt PC 8 3 3 Receive data from slave PC gt MC150 EOT AD1 AD2 STX C1 C2 C3 C4 ENO The correct reception of the string is acknowledged with the following message MC150 gt PC STX C1 C2 C3 C4 DATA ETX BCC The reception of a incorrect string is followed by a negative acknowledgment like MC150 gt PC STX C1 C2 C3 C4 EOT in any other cases with NAK MC150 gt PC Example Read actual value unit address 11 PC MC150 EOT AD1 AD2 STX C1 C2 C3 C4 ENO ascii 1 1 21110191019 Hex 04 31 31 02 32131139 39 05 If actual value 12 acknowledge message will be MC150 PC _ stx c1 c2 c3 ca DATA_ ETX BCC jase 22 So 18 I www lika it www lika biz sales phsystems be lixa 8 3 4 Serial commands All commands are sent with parameter P52 C1 C2 C3 C4 fields 2152 See Send data from Master to Slave chap 8 3 2 The following commands are available Activate data DATA 137 Save data to EEProm DATA 138 Set datum DATA 139 Example Send Activate data unit address 11 PC M
7. C150 AD2 STX c2 1 DATA ETX BCC ascii 1 3 7 MC150 gt PC ACK EOT AD1 8 3 5 Printer mode When a printer is connected to the MC150 the following data string will be transmitted MC150 gt printer AD1 AD2 DATA xx xx LF CR OA Hex OD Hex The MC150 is sending its serial address followed by the actual value and Line Feed LF and Carriage Return CR 9 Dimensional drawing and cut out Check details on product catalogue Provide a 90 x 66 mm w x h cut out MAN MC150 I_E 1 7 PH SYSTEMS www phsystems be MC150 of f 10 tissue i O p f 1 Manualupdate 6 03 08 Chap 5 6 7 and 8 corrections Chap 5 8 2 and parameter P62 corrections Add parameter P22 ii s u KA Lika Electronic Via S Lorenzo 25 36010 Carr VI Italy Tel 39 0445 382814 Fax 39 0445 382797 Italy eMail info lika it www lika it World eMail info lika biz www lika biz www lika it www lika biz 16 sales phsystems be
8. input supply for output 2 Power supply 24Vac 6 Input 3 FREEZE STOP function L Pint L SI Pin2 ne 8 input1 RESET function Pin3 ne 9 OND output for function inputs a Pin 4 N max 150 mA Pin5 P E available only with MC150 P1 n c Not connected Power supply 115Vac O L ig Pia L O O 24V GND NI Pin2 N OO see P13 i Pin3 L BE gt Pin 4 N max 100 mA ci Pins PE 94 Power supply 230Vac AV GND L E Pind L 5 4 CON4 connections RS232 EE Pin2 Connect to pin 3 Pin Function i i Pin3 Connect to pin 2 1 RxD ae Pin 4 N max 100 mA 2 TxD ee pe MAN MC150 I_E 1 7 10 www lika it www lika biz PH SYSTEMS www phsystems be sales phsystems be lixa 5 5 J1 jumper encoder power supply Left 10Vdce 30Vdc MC150 Right 5Vdc see chapter 5 2 CON2 connections 5 6 J2 jumper input signal level Position Function Input connected with GND CON3 Pin9 Right Input connected with 24Vdc i CON3 Pin10 6 Functions 6 1 Start up At start up the unit shows the software version followed by actual position Software version SOF xx 6 2 Key functions Laas W gt E Shift Right Function Enter Up Function Function save exit setup Shift Right select parameter digit Up change va
9. l screw moves 12 3mm per revolution The system uses a rotary encoder with 200 PPR pulses per revolution In this case POO should be set to 123 value without decimals PO1 is 200 Moving Carrier qm LIII Llll m l I f J E www lika it www lika biz sales phsystems be lixa PO2 Encoder edge counting mode 1 3 1 x 1 1 edge counting mode 2 x 2 2 edge counting mode 3 x 4 4 edge counting mode For linear magnetic measurement systems set 3 Example A magnetic sensor SME5 with 0 01mm resolution has to be displayed The measurement length is 100 00 mm The sensor outputs 10000 pulses after quad POO is 10000 100 00mm without decimals PO1 is 10000 pulses P02 is 3 signal quadrature P03 Counting direction 0 1 Sets counting direction of display 0 standard counting direction 1 inverted counting direction P04 Decimal point 1 4 Modification of decimal point position This setting has no influence on other parameters O 000000 1 00000 0 4 00 0000 PO5 Password Level 1 0 999999 Enter desired code number here to prevent Operator from entering the Datum value mode Level 1 Default value O Attention Datum value can be set only after digiting the correct password To cancel password and restore default value see chapter Default parameter 6 2 1 POG Password Level 2 0 999999 Enter desired
10. lixa User manual MC150 Description This manual describes the MC150 display series The purpose of this device is to display linear or angular displacements on industrial machines and automation systems The device can be connected to standard Push Pull or Line Driver incremental encoders or magnetic sensors Chapters Safety summary Identification Installation Mounting recommendations Electrical connections Functions Set up RS232 interface Dimensional drawing and cut out Omonr oan WN gt MAN MC150 I_E 1 7 1 Safety summary For the electrical connections we recommend to closely follow these electrical instructions In particular according to the 89 336 EEC norm on electromagnetic compatibility following precautions must be taken e Measurement system sensor should be installed as close as possible to the display e Always use shielded and twisted cables if possible e Avoid running the sensor cable near high voltage power cables e g drive cables e Install EMC filters on sensor power supply if needed e Avoid mounting sensor near capacitive or inductive noise sources such as relays motors and switching power supplies e Static discharge can damage internal sensitive electronic components Before handling and installing discharge electrical charge from your body and tools A which may come in touch with head the device Connect according to the chapter 5 Electrical connections
11. lue Enter save scroll menu 6 2 1 Default parameter factory settings Default parameter values are written in BOLD characters The unit can be reset to default values by pushing F 48 and E key while switching on 6 2 2 Direct functions To set direct functions such as reset reset with datum value tool correction offset value absolute relative display mode and mm Inch display mode program PO7 parameter MAN MC150 I_E 1 7 PH SYSTEMS www phsystems be 11 7 Set up 7 1 Access to setup menus Push F key to enter setup e push to select Func 1 or Func 2 push E to scroll parameters push F to exit setup Admissible value range for each parameter is listed as follows min value max value 7 2 Parameter setting In order to activate modified parameters switch off and on the device Level 1 Func1 POO Datum value Eich 99999 999999 Display can be set to datum value or preset by activating SET input or pushing key Default value 50 0 Level 2 Func2 POO Display value per distance moved 1 10000 Enter the value to be displayed when the unit receives the number of pulses per distance moved in parameter PO1 Note this value is entered without decimal Default value 100 PO1 Nr of pulses per distance moved 1 65000 Enter the number of pulses per distance This same distance unit is used to determine the Display value per distance moved Default value 100 Example A bal
12. ress of the readout when using the serial interface option RS232 Don t use addresses 20 30 40 90 Default value 11 P61 Baud rate 0 4 MC150 8 RS232 interface 8 1 PC connection lt i fins Use 9 pin DSub connector and connect with CON4 4800 of the MC150 readout 2 9600 3 19200 4 38400 Tx Transmission data P62 RS232 mode 0 3 0 RS232 protocol according to DIN66019 1 Printer mode To transmit actual value periodically to a printer at a time interval set in parameter P63 2 Printer mode To transmit actual value to a printer when pushing E button attention to P07 do not use 1 4 and 16 functions 3 Printer mode To transmit actual value to a printer when activating Input CON3 pin 5 attention set P12 0 P63 Transmission time interval 0 01 650 00 Enter the time interval for periodic actual value transmission in sec P62 must be 1 Default value 1 00 P99 Actual value for RS232 99999 999999 This parameter shows the actual value for serial transmission via RS232 Interface if parameter P62 0 NOTE In order to activate modified parameters switch off and on the device MAN MC150 I_E 1 7 RxD Reception data D issi Make sure that RxD on PC side is connected with TxD on MC150 side and TxD PC is connected with RxD MC150 8 2 Technical data Function Data Baud rate 2400 4800 96

Download Pdf Manuals

image

Related Search

Related Contents

operación - Lincoln Electric  EVGA 03G-P3-1591-ER NVIDIA GeForce GTX 580 3GB graphics card  Tucano Polpo  Höcherl & Hackl Elektronische Last PL1512 Standard Rev.1  Hinweise für die Sicherheit  GBT-SCA Updates and chip results - Indico  第2学年  Whirlpool Compactor User's Manual  Samsung SCH-R270ZKAXAR User's Manual    