Home

PRODUCT CATALOG

image

Contents

1. lt E E B BEB BH UX90 UX100 UX120 ES amp DC Voltage Part number T MAG SPT 150 T MAG SPT 300 T MAG SPT 600 T CON ACT 150 T CON ACT 300 S CIA CM14 S VIA CM14 CABLE ADAP5 CABLE ADAP10 CABLE ADAP24 CABLE 4 20MA CABLE 2 5 STEREO S FS CVIA Type 150 Volt AC potential transformer 300 Volt AC potential transformer 600 Volt AC potential transformer ConLab 0 150 Volt AC transmitter ConLab 0 300 Volt AC transmitter 12 bit 4 20mA input adapter 12 bit voltage input adapter Voltage input cable 0 5 VDC Voltage input cable 0 10 VDC Voltage input cable 0 24 VDC Measures currents from 0 to 20 1 mA Voltage input cable 0 2 5 VDC FlexSmart analog module 2 channels RX3000 U30 E N RR UX90 UX100 UX120 lt ES 40 External Sensors by Measurement Energy Power continued Amp Hour Amps Power Factor Volt Amp Reactive Volt Amp Reactive Hour Volt Amps Volts Watt Hours Watts Part number Type RX3000 U30 H21 H22 U12 U14 ZW UX90 UX100 UX120 T VER E50B2 Power amp Energy meter V V V V V V Part number Type RX3000 U30 H21 H22 012 014 ZW UX90 UX100 UX120 S UCC M001 Electronic switch pulse input adapter 1m S UCC M006 Electronic switch pulse input adapter 6m V V V S UCD M001 Contact closure pulse inpu
2. Compressed Air Flow DC Current DC Voltage Differential Pressure Gauge Pressure Kilowatt Hours Kilowatts Power Factor Pulse Signals Temperature Relative Humidity Dew Point Volatile Organic Compound Volt Amp Reactive Volt Amp Reactive Hour Volt Amps Water Flow Watt Hours Watts Volts Amps 0 10 VDC 4 20mA Key Advantages monitor not included Provides real time centralized data collection within a facility Minimum System Requirements Scales up to a network of 100 nodes sending data to a single receiver Creates self healing network to overcome obstructions in communication paths Provides one year battery life 15 minute logging intervals am Provides alarm notifications via email or text messages Satware Receiver Datsfiode Features powerful software for organizing and viewing data as well as the included wireless network For complete information and accessories please visit www onsetcomp com up to 95k 5k 4k Buffer memory measurements measurements measurements 3k measurements Ext T RH 1 2 analog ports Measurements N A Temp Temp RH analog port gua 2 pulse input N A 1 pulse input port 9 9 5 Probe size N A N A N A 1cm 0 38 in dia N A 1 0 38 in dia N A N A Sample rate N A 1 min to 18 hrs 1 min to 18 hrs 1 min to 18 hrs 1 min to 18 hrs 1 min to 18 hrs 1 min to 18 hrs N A Transmission rate N A 2 min amp greater 2 min amp greater 2 min amp g
3. NEW RX3000 Remote Monitoring System Real time access to data from any web browser The HOBO RX3000 is a research grade data logging station that combines greater measurement flexibility and an on board LCD display in a rugged easy to deploy package 1 1 Supported Measurements HABO Indoor Environmental Temperature Relative Humidity Dew Point C02 Air Velocity VOC Energy Power 4 20mA AC Current AC Voltage Amp Hour Amps Compressed Air Flow DC Current DC Voltage Differential Pressure Gauge Pressure kW kWh Power Factor Pulse Input Volt Amp Reactive Volt Amp Reactive Hour Volt Amps Volts Water Flow Watt Hours Watts Key Advantages Cloud based data access Minimum System Requirements Plug and play operation cm Flexible support for a broad range of sensors a LCD display for easy field deployment Software Dataplan Power Sensor e Alarm notifications via text email copa de dB suc 1596039 e Rugged double weatherproof enclosure For complete information and accessories please visit www onsetcomp com Smart Sensor Connectors 10 up to 15 data channels some sensors use more than one data channel Maximum Number of Sensors 18 when 2 Analog Modules are configured in the station Smart Sensor Cable Length 100 m 328 ft maximum Module Slots 2 for optional Analog or Relay module see manual for detailed module specification Fas
4. TMC6 HE Pipe Temp 6 cable V This logger is intended for indoor environments but sensors are compatible Requires UX100 014M Thermocouple logger 1 Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 44 onsetcomp com External Sensors by Measurement Weather Field continued Part number Type RX3000 U30 H21 UX90 UX100 UX120 S LIA M003 Photosynthetic light PAR v v Part number Type RX3000 U30 H21 UX90 UX100 UX120 S LIB M003 Solar radiation V V V Part number Type RX3000 030 UX90 UX100 UX120 S BPB CM50 Barometric pressure V V S BPA CM10 HWS barometric pressure V Part number Type RX3000 U30 H21 UX90 UX100 UX120 S WDA M003 Wind direction 3m cable S WSB M003 Wind speed Smart Sensor 3m cable S WSET A Wind Smart Sensor set S WCB M003 R M Young wind monitor AQ adapter V V V S WCC M003 R M Young marine wind adapter S WCE M003 R M Young wind monitor adapter Part number Type RX3000 U30 UX90 UX100 UX120 S RGA M002 01 Rain gauge Smart Sensor 2m cable S RGB M002 2mm Rain gauge Smart Sensor 2m cable V V V Part number Type RX3000 U30 UX90 UX100 UX120 S SMC M005 EC 5 soil moisture Smart Sensor ns S SMD M005 10HS soil moisture Smart Sensor V V V 9 Part number Type RX3000 U30 H21 UX90 UX100 UX120 S LWA M003 Leaf wetness
5. Memory 42 000 measurements Logging interval 1 second to 18 hours fixed or multiple rate up to 8 user defined sampling intervals Battery life 6 years with 1 minute or greater logging interval factory replaceable ONLY Measurement range 40 to 70 40 to 158 F in air maximum sustained temperature of 50 C 122 F in water Accuracy 0 21 C over 0 to 50 x 0 38 F over 32 to 122 F Resolution 0 02 C at 25 C 0 04 F at 77 F Response time 90 5 minutes in water 12 minutes in air moving 2 m sec typical Dimensions 3 0 cm 1 19 in maximum diameter 11 4 cm 4 5 in length mounting hole 6 3 mm 0 25 in dia CE compliant Yes Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details Coupler included with HOBO Base Station or HOBO Waterproof Shuttle onsetcomp com 26 HOBO Pendant Loggers Low cost data logging solution for temperature light and more HOBO Pendant data loggers are economical weatherproof and waterproof temperature data loggers designed for a variety of short and long term monitoring applications Supported Measurements Temperature Light Intensity Tilt Acceleration Key Advantages e Low cost temperature light intensity and acceleration loggers e Waterproof housing for wet or underwater use e Data readout in less than 30 seconds via Optic USB interface Minimum System Requirements Software Base Station See pg 35 See pg 46 g
6. 134 AL Mobile device with iOS 8 3 8 4 or 9 0 Bluetooth 4 0 or later 29 onsetcomp com HOBO MX2001 Water Level Logger Innovative Two sensor design provides direct water level readout without vent tubes User replaceable batteries Interchangeable kevlar reinforced cable Integrated barometric pressure sensor Bluetooth Low Energy BLE communication Durable ceramic sensor For complete information and accessories please visit www onsetcomp com Water Level Approx 0 to Approx 0 to 30 6 Approx 0 to 76 5 m Approx 0 to 4 9 to 30 ft 0 to 100 ft 0 to 251 ft 0 to 13 ft Calibrated Range 0 to 69 to 207 kPa 69 to 400 kPa 69 to 850 kPa 69 to 145 kPa 40 C 32 to 104 F 10 to 30 psia 10 to 58 psia 10 to 123 3 psia 10 to 21 psia Accuracy Typical 0 05 FS 0 5 cm 0 05 FS 1 5 cm 0 05 FS 3 8 cm 0 07596 FS 0 3 cm TUR 0 015 ft 0 05 ft 0 125 ft 0 01 ft 0 02 kPa 0 003 psi lt 0 04 kPa 0 006 psi lt 0 085 kPa 0 012 psi lt 0 014 kPa 0 002 psi 0 21 cm 0 007 ft water 0 41 cm 0 013 ft water 0 87 cm 0 028 ft water 0 14 cm 0 005 ft water Temperature Range 20 to 50 C 4 to 122 F Accuracy 0 44 C from 0 to 50 C 0 79 F from 32 to 122 F Resolution 01 C ai 25 C 0 16 Fat 7 7 F Barometric Pressure Range 66 to 107 kPa 9 57 to 15 52 psia Accuracy typical 0 075 FS 0 3 cm 0 01 ft water Logger Specifications
7. 25 7 cm high 6 x 10 in 1 2 kg 2 5 Ibs Yes HOBO Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details onseicomp com 16 MN HOBO Pendant Event Measures temperature events and rainfall The HOBO Pendant Event data logger is ideal for rainfall logging and connects to most standard tipping bucket rain gauges to determine rainfall rates times and duration Supported Measurements Temperature Event Rainfall Key Advantages Records tips or momentary contact closures and temperature Event based data storage provides detailed data and efficient memory usage e Stores over 16 000 tips 160 inches of rainfall with a 0 01 inch rain gauge e Includes scaling to inches millimeters or other units Minimum System Requirements ZA Software Base Station See pg 35 See pg 46 For complete information and accessories please visit www onsetcomp com Events only 16K to 23K events Events and temperature 25K to 30K data points 1 year typical user replaceable CR2032 Rain Gauge Tips Memory Battery life External Event type Connection Maximum input frequency Measurement range Accuracy Resolution Response time Sample rate Dimensions CE compliant Relay contact closure or rain gauge tips 2 m 6 ft cable with 2 wire input 1 Hz 1 pulse per second Temperature 20 to 70 C 4 to 158 F 0 53 C from 0 to 50 0 95 F from 32
8. 0 04 C 0 07 F 0 02 C 0 03 F 0 03 C at 0 05 F 0 08 C 0 15 F 0 08 C 0 15 F 0 1 C 0 18F 0 06 C 0 11 F USB cable included with software part BHW PRO CD onseicomp com HOBO UX120 4 Channel Pulse Logger Log pulse signals events state changes and runtimes The HOBO UX120 4 Channel Pulse data logger is a highly versatile 4 channel energy data logger that combines the functionality of four separate energy loggers into one compact unit It enables energy management professionals from energy auditors to building commissioners to easily track building energy consumption equipment runtimes and water and gas data logger flow rates B Supported Measurements Pulse Signals Event Runtime State AC Current AC Voltage Amp Hour Kilowatt Hours Kilowatts Motor On Off Power Factor Volt Amps Watt Hours Watts Volt Amp Reactive Volt Amp Reactive Hour sensors sold separately Key Advantages Simultaneously measures and records pulse signals events state changes and runtimes Stores over 4 million measurements enabling longer deployments with fewer site visits Streamlines deployment via range of start stop options logger status LEDs and high speed USB 2 0 data offload Works with Onset s E50B2 Power amp Energy Meter to measure Power Factor Reactive Power Watt Hours and more Minimum System Requirements Software USB cable Sensor See pg 35 See
9. to 70 C 4 to 158 F 0 95 RH non condensing Dimensione 3 66 x 5 94 x 1 52 cm 3 66 x 8 48 x 1 52 cm 3 66 x 8 48 x 2 36 cm 3 66 x 8 48 x 2 87 cm 1 44 x 2 34 x 0 6 in 1 44 x 3 34 x 0 6 in 1 44 x 3 34 x 0 93 in 1 44 x 3 34 x 1 13 CE compliant Yes onsetcomp com 4 HOBO 0 120 Plug Load Logger Measures power and energy consumption of 120V office equipment plug loads Onset s HOBO Plug Load Logger is a high accuracy easy to deploy data logger that measures and records the power and energy consumption of 120V plug loads from office equipment vending machines and other devices The logger provides 0 5 measurement accuracy with a measurement resolution of 1 watt making it an ideal choice for building audits where detailed energy use data is required The rugged housing is designed to withstand the rigors of real world handling providing reliable performance despite bumps drops and use under desks Supported Measurements AC Current AC Voltage Amps Kilowatt Hours Power Factor Volt Amps Volts Watt Hours Watts Key Advantages 0 5 measurement accuracy enables more reliable plug load energy use data Meter Mode provides instant viewing of real time plug load variables Large memory enables faster logging intervals for more comprehensive plug load profiles Battery back up ensures logged data remains intact in the event of a power outage or load failure Full featured LCD display provides
10. 0 1 20 C 0 18 68 F Response time 5 minutes to 90 in water Dimensions 2 46 cm diameter x 15 cm 0 97 x 5 9 in hole in mounting bail 6 3 mm 0 25 in CE compliant Yes Titanium version recommended for saltwater deployment HOBO Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details 2Coupler included with HOBO Base Station or HOBO Waterproof Shuttle 31 onsetcomp com 1201 Series Water Level Loggers A new standard for price performance HOBO U20L Series Water Level loggers set a new standard for price performance for accurate water level and temperature monitoring The loggers combine 0 1 measurement accuracy a polypropylene housing for use both fresh and salt water and a non vented design for convenient and hassle free deployment Supported Measurements Water Level Barometric Pressure Pressure Absolute Temperature 1 Key Advantages e Self contained non vented design enables easy deployment Ideal for use in both fresh and saltwater environments Durable ceramic pressure sensor Ideal for use in wells streams lakes wetlands and tidal areas Minimum System Requirements Software Base Station Coupler See pg 35 See pg 45 gt For complete information and accessories please visit www onsetcomp com HOBO Water Level Specifications Ranae 0 4 m 0 13 ft 0 9 m 0 30 ft 0 30 6 m 0 100 ft g 0 to 145 kPa 0 to 21 psia
11. 0 to 207 kPa 0 to 30 psia to 400 kPa 0 to 58 psia 69 to 145 kPa 69 to 207 kPa 69 to 400 kPa 10 to 21 psia 10 30 psia 10 to 58 psia 32 to 104 F Water Level Accuracy 0 4 cm 0 013 ft 1 0 cm 0 03 ft 3 0 cm 0 1 ft Typical Error 0 1 FS 0 1 FS 0 1 FS Resolution 0 14 cm 0 005 ft water 0 21 cm 0 007 ft water 0 41 cm 0 013 ft water 310 kPa 45 psia 310 kPa 45 psia 500 kPa 72 5 psia DUISEPTOSSHTO 18 m 60 ft depth 18 m 60 ft depth 40 8 m 134 ft depth Temperature Specifications all models Range 20 to 50 C 4 to 122 F Accuracy 037 20 067 686 0 44 from 0 to 50 C 0 79 from 32 to 122 Resolution 10 bit 0 1 20 C 0 18 68 F Response time 10 minutes to 90 in water Dimensions 3 18 cm diameter x 15 24 cm 1 25 x 6 0 in hole in mounting bail 6 3 mm 0 25 in CE compliant Yes 1HOBO Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details Coupler included with HOBO Base Station or HOBO Waterproof Shuttle onsetcomp com 32 I1 111 HOBO Conductivity Loggers Conductivity monitoring for freshwater and stable saltwater applications HOBO Conductivity Loggers are convenient rugged and cost effective data loggers for a variety of freshwater and saltwater monitoring applications HOBO ove Logger onset Range O00 The HOBO U24 001 model provides
12. BASE U 4 504 loggers 8k memory Storage Capacity 63 loggers 64k memory V V 7 loggers 512k memory 0 90 v HOBO UX100 v HOBO UX120 NE HOBO 012 v HOBO U24 VB v v HOBO U26 VB v y HOBO Pendant VB 020 VB v v HOBO U22 VB v v HOBO U23 vB v v UTBI TidbiT Temp V2 VB V RG3 Rain Gauge vB V V V HOBO H21 v v HOBO H22 V V HOBO U30 Couplers are included Products with a VB require a Base Station for use with the U Shuttle 1 CE Compliant onsetcomp com 46 The Onset Advantage Responsiveness Your projects have tight deadlines that your monitoring partner must be able to meet Onset offers a highly responsive dynamic manufacturing environment where we build and ship all our products directly from our headquarters on Cape Cod Our centralized operations and large capacity enable us to provide fast turnaround to meet your tight project deadlines Most orders ship within 24 hours Applications Expertise With more than three decades of experience in solving data logging applications Onset has developed an applications expertise that is second to none Whether you are measuring building energy performance or studying water and field ecology chances are we have seen your application before and know what it takes to solve it Reliable Accurate Data No matter what your application involves at the end of the day it all comes down to the integrity of your data HOBOs
13. Can be used either as a data shuttle or an Optic USB Base Station Supports all HOBO Optic USB loggers Outdoor or underwater data readout Convenient direct USB connection to host computer Waterproof to 20 meters Checks and indicates its own battery status The HOBO Optic USB Base Station and a series of couplers are used to offload data from any HOBO data logger with an Optic USB interface The Optic USB Base Station connects to your computer via USB while connecting to the logger via an appropriate coupler Key Advantages Provides fast optical infrared IR communications for easy launch and readout of all HOBO Optic USB loggers Splash resistant Not compatible with UX120 006M onseicomp com _ _ _ _ Data Shuttles Base Stations The Pendant Base Station and Coupler provide fast optical infrared IR communication for easy logger launch and readout of HOBO Pendant loggers The Base Station connects via USB to a host computer while the coupler attaches the logger to the Base Station for communications Key Advantages Provides fast optical communications for easy launch and readout of all HOBO Pendant loggers Connects via USB cable to host computer Splash resistant Pendant Base Station BASE U 1 U Shuttle U30 Shuttle Waterproof Pendant Optic USB Data Transporter Data Transporter Shuttle Base Station Base Station U DT 1 U DT 2 U DTW 1 BASE U 1
14. Compressed Air Flow DC Current DC Voltage Gauge Pressure Kilowatts Light Intensity Volatile Organic Compound some sensors sold separately HOBO logge p emp channel Key Advantages um Records up to 4 channels Your choice of 2 models with flexible measurement options Programmable as well as push button start Compatible with a broad range of external sensors Minimum System Requirements Software USB cable See pg 35 For complete information and accessories please visit www onsetcomp com Memory 43 000 measurements Sampling rate 1 second to 18 hours user selectable Battery life 1 year typical user replaceable CR2032 Temperature Max range 20 to 70 4 to 158 F Accuracy 0 35 C from 0 to 50 C 0 63 F from 32 to 122 F Resolution 12 bit Measurement range Accuracy Resolution 10 bit Range Range Accuracy Resolution CE compliant 0103 25 0105 F 77 F Relative Humidity 5 to 95 RH non condensing 2 5 typical 3 5 maximum from 10 to 90 RH 0 03 RH Light Intensity Designed for general purpose indoor measurement of relative light levels 1 to 3000 footcandles lumens ft2 typical 0 32 300 lumens m2 External Input 0 to 2 5 VDC 2 mV 2 5 of absolute reading 0 6 mV Yes USB cable included with software part BHW PRO CD Note Temp amp RH NIST certification services available for this product Please visit onse
15. Operating Range 20 to 50 C 4 to 122 F Transmission Range Approximately 30 5 m 100 ft line of sight Top end MX2001 TOP 2 54 1 0 inches diameter 28 9 cm 11 4 inches length Sensor end MX2001 0x S and MX2001 0x Ti S 2 54 cm 1 0 inches diameter 9 91 cm 3 9 inches length CE compliant Yes FCC compliant Yes Mobile Device Compatibility iOS 8 3 8 4 amp 9 0 and Bluetooth 4 0 or later Bluetooth Compatibility Bluetooth 4 0 or later Bluetooth Low Energy Bluetooth Smart See pages 43 44 for additional accessories Direct read cables can be ordered in lengths from 0 2 m to 500 m onsetcomp com 30 S HOBO U20 Series Water Level Loggers Accurate affordable water level monitoring HOBO Water Level data loggers offer high accuracy at an affordable price with no cumbersome vent tubes or desiccants to maintain These data loggers are ideal for recording water levels and temperatures in wells streams lakes wetlands and tidal estuaries miM Supported Measurements Water Level Barometric a RES RITE Pressure Pressure Absolute Temperature Water Lowel Logger ange D fo d Key Advantages Available in 4 depth ranges No vent tube design for easy and reliable deployment Available in stainless steel and titanium versions Durable ceramic pressure sensor for reliable performance Calibration certificate included Water Level Logger Kits Deluxe Kit includes a carrying case two HOBO
16. 8 3 8 4 amp 9 0 or Android 4 4 5 0 5 1 and Bluetooth 4 0 or later Bluetooth Compatibility Bluetooth 4 0 or later Bluetooth Low Energy Bluetooth Smart Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 onseicomp com Onset s HOBO MX1102 CO2 logger makes it more convenient than ever to measure and record COo in buildings and other non condensing environments It measures from 0 5 000 parts per million ppm and our free HOBOmobile app allows you to access data right from your mobile phone or tablet within a 100 foot range The MX1102 also features a USB port so it can be used with a computer running HOBOware Pro graphing and analysis software Supported Measurements HOBO MX1102 Logger Bluetooth Low Energy CO2 temperature and relative humidity data logger Temperature Relative Humidity Dew Point Key Advantages Wireless communication via Bluetooth Low Energy technology Six month battery life at 5 minute CO2 logging rate Easy to deploy and offload using free HOBOmobile App Visual and audible high amp low alarm thresholds HOBOmobile Mobile Self calibrating CO2 sensor technology ensures optimal Minimum System Requirements 4 Download the App Store ANDROID APP ON gt Google play See pg 36 device accuracy at lower maintenance cost
17. A E50B2 LEADSET Wiring kit for T VER E50B2 only A WNB LEADSET Voltage input lead set with alligator clips ED A BOOT BLK Protective boot black cap included V BOOT WHT Protective boot white cap included V 85 CAPLUG H20 B Replacement cap for protective boot black V 85 CAPLUG H20 W Replacement cap for protective boot white V BOOT TIDBIT BK Protective boot black 5 ea BOOT TIDBIT WH Protective boot white 5 ea 020 1 Carrying case V CABLE 1 50 Teflon coated SS cable 50 ft CABLE 1 300 Teflon coated SS cable 300 ft V vv CABLE 1 CRIMP sleeve 12 ea for above cables SOLAR 3W 3 watt 6 volt solar panel vV SOLAR 6W 6 watt 6 volt solar panel E E AC U30 AC power adapter for the U30 AC U30 EU v RS1 Solar radiation shield V Solar radiation shield assembled V V vV V RS3 Solar radiation shield U23 RS CLAMPKIT Mounting clamp 2 required V UX90 LIGHT PIPE 1 1 foot fiber optic attachment for HOBO UX90 V CASE PELICAN 1510 Pelican case durable watertight FAA carry on V VV Vv vv vv VV CASE 4X 2 Protective weather resistant case S 28 SNGacQlFRNRRRRSERERSES T Re en ee a em a oe MX2001 TOP HOBO MX Water level logger Top End MX2001 04 S MX Water Level Sensor End 4m 13 V MX2001 01 S MX Water Level Sensor End 9m 30 2001 02 5 MX Water Level Sensor 30m 100 V MX2001 03 S MX W
18. CE compliant Yes gt For complete information and accessories please visit www onsetcomp com 4 minutes to 9096 11 seconds to 9096 Minimum System Requirements Software USB cable See pg 35 USB cable included with software part BHW PRO CD Memory 84 650 measurements Sampling Rate 1 second to 18 hours user selectable Battery Life 1 year typical with logging rate of 1 minute and sampling interval of 15 seconds or greater user replaceable CR2032 Dimensions in 3 66 x 8 48 x 1 52 cm 1 44 x 3 34 x 0 6 in Temperature Range 20 to 70 4 to 158 F Accuracy 0 21 C from O to 50 C 0 38 F from 32 to 122 F Resolution 0 024 C at 25 C 0 04 F at 77 F 6 minutes to 90 1 to 95 2 5 from 10 to 90 0 05 at 25 C 77 F 5 minutes to 90 Memory 208 076 measurements Sampling Rate 1 second to 18 hours user selectable Battery Life 1 year typical with logging rate of 1 minute and sampling interval of 15 seconds or greater user replaceable CR2032 Dimensions 3 66 x 8 48 x 1 52 cm 1 44 x 3 34 x 0 6 in Operating Range Logging 20 to 70 C 4 to 158 F 0 to 95 RH non condensing Thermocouple Range Accuracy Resolution probes sold separately Type J 210 to 760 C 346 1 400 F 0 6 C 1 08 F thermocouple probe accuracy 0 03 C 0106 Type K 260 to 1 370 C 436 to 2 498 F 0 7 C 1 26 F thermocouple probe accuracy 0 04 C 0 07 F Type T 2
19. DR 060 60m Direct Read Cable V CABLE DR xxx xxxm Custom Length Direct Read Cable SUBC2 xx For HOBO U10 and U12 underwater use HOUSING U2X Protective Housing So Part number Type N 8 NntonmyvoS OSES a ee ee I Z 9 23225225 3 D D 2 1 Lithium batteries box of 5 V V HRB U30 S100 10 Ahr battery w cable v HP B Replacement battery for HOBO U23 V For factory battery replacement and calibration services please call 1 508 759 9500 or 1 800 LOGGERS b T m ps OWN RRUSTERRERERSESEEEKEERX I IL Z DDDDDDDD D D D 2 COUPLER UA Coupler for use with BASE U 4 V COUPLER2 A Coupler for use with BASE U 4 COUPLER2 B Coupler for use with BASE U 4 COUPLER2 C Coupler for use with BASE U 4 V V vV COUPLER2 D Coupler for use with BASE U 4 V COUPLER2 E Coupler for use with BASE U 4 S 28 T en v N SR SSBERRERSESEEKRKZEE L a2 55 5 55 5 SMC J For type J wire V SMC K For type K wire For type wire 1 Not compatible with UX120 006M 2 xxx is cable length in meters ranging from 0 2m to 500m cable length increments are larger for longer lengths 43 onsetcomp com Accessories B SR STEREESRSEESSERKEER E LI cur 555 5 5 5 5 2 T VER AH02 Single phase fuse kit for T VER E50B2 only
20. MA SS oe LL E 171 elie fais T Get data automatically Configure HOBOlink to automatically deliver data from RX3000s to other web based services such as Weather Underground 38 External Sensors by Measurement Indoor Environmental Temperature Part number Type RX3000 030 H21 H22 U12 U14 ZW UX90 UX100 UX120 S THB M002 12 bit Temp RH smart 2m cable V S THB M008 12 bit Temp RH smart 8m cable V V S TMB M002 12 bit Temp RH smart 2m cable V V S TMB M006 12 bit Temp smart 6m cable V S TMB M017 12 bit Temp smart 17m cable TC6 J Type J beaded thermocouple V TC6 K Type K beaded thermocouple V TC6 T Type T beaded thermocouple V V TCP6 K12 Type K Probe thermocouple TMC1 HD Air Water Soil Temp 1 cable V V TMC6 HD Air Water Soil Temp 6 cable TMC20 HD Air Water Soil Temp 20 cable V 50 Air Water Soil Temp 50 cable V TMC6 HC Stainless steel Temp probe 6 cable V TMC6 HE Pipe Temp 6 cable Relative Humidity Part number Type RX3000 U30 H21 H22 U12 U14 ZW UX90 UX100 UX120 S THB M002 12 bit Temp RH smart 2m cable S THB M008 12 bit Temp RH smart 8m cable V V V V V Carbon Dioxide Part number Type RX3000 U30 H21 H22 U12 U14 ZW UX90 UX100 UX120 TEL 7001 Telaire 7001 CO2 V Air Velocity Part numbe
21. Power amp Energy meter WattNode 208 240 VAC 3 phase WattNode 480 VAC 3 phase WattNode 208 240VAC 2 or 3 Branch WattNode 208 240 VAC 1 2 or 3 Phase Veris 480 V 100 Amp Kilowatt transducer Veris kWh transducer 1 Phase 300 Amp Veris kWh transducer 3 Phase 800 Amp RX3000 U30 H21 E lt 5 E 5 E B B EB ES Bi os ee EN S UX90 UX100 UX120 lt ES E E E amp DC Current Part number CTV A CTV B CTV C CTV D CTV E T MAG 0400 05 T MAG 0400 20 T MAG 0400 50 T MAG 0400 75 T ACT 0750 020 T ACT 0750 050 T ACT 0750 100 T ACT 0750 250 T MAG SCT 100 T MAG SCT 200 T MAG SCT 600 T VER 971BP 200 T VER H970 200 Type 2 20 Amp split core AC current sensor 5 50 Amp split core AC current sensor 10 100 Amp split core AC current sensor 20 200 Amp split core AC current sensor 60 600 Amp split core AC current sensor 0 5 5 AMP split core AC transformer 2 20 AMP split core AC transformer 5 50 AMP split core AC transformer 7 5 75 AMP split core AC transformer 0 2 20 Amp split core AC transformer 0 5 50 Amp split core AC transformer 1 100 Amp split core AC transformer 2 5 250 Amp split core AC transformer 10 100 Amp split core AC transformer 20 200 Amp split core AC transformer 60 600 Amp split core AC transformer Split Core Bi Polar DC transducer Split Core 200A DC transducer RX3000 U30
22. Smart Sensor Part number Type RX3000 U30 UX90 UX100 UX120 S THB M002 12 bit Temp RH smart 2m cable V V A a Y S THB M008 12 bit Temp RH smart 8m cable V This logger is intended for indoor environments but sensors are compatible Compliant This logger is intended for indoor environments but sensors are compatible 1 Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 onsetcomp com 42 Accessories NR ntonmyvo vong a SN eO X cr NM e 5 M X TIeDDDDDSDDS S5D DS555NE U DT 1 U Shuttle data transporter 2 E U DT 2 U30 shuttle data transporter v U DTW 1 Waterproof shuttle V vV BASE U 1 Pendant base station Vv BASE U 4 Optic USB base station J number ntoamyvoRSODSES a TIeDDDDDDDS S5D 555NE CABLE PC 3 5 Serial interface cable for H series HOBOs CABLE USBMB USB cable for HOBO U Series Vv Vv ADAPT SER USB USB to serial interface cable for H series HOBOs v D DDDDDDD D D D DDN WELL CAP 01 2 5cm Well Cap V v CABLE DR 5 0 5m Direct Read Cable CABLE DR 010 10m Direct Read Cable CABLE DR 015 15m Direct Read Cable V CABLE DR 030 30m Direct Read Cable CABLE
23. TPA KIT 3 meter tripod M TPA 1 2 in Stake Kit M SKA for guy wires Grounding Kit M GKA Guy Wire Kit M GWA EN sh Mast Level M MLA 3 Meter Tripod SS shown at right Height range 2 74 to 3 20 m 9 to 10 5 ft eb Mast diameter 4 1 cm 1 63 in Weight 12 7 28 Ibs Maximum slope 13 degrees for installation on moderately uneven ground M GKA Grounding Kit is recommended when using tripods in exposed locations onsetcomp com HOBO Weather Stations Wind Speed oy Rain Gauge Light Sensor Fy Bracket Solar Radiation Shield Solar Panel RX3000 030 H21 3 Meter Tripod with Mast Wind Direction and u bolts for mast mounting Full Cross Arm Light Sensor Bracket M LBB Includes leveling screws Solar Radiation Shield RS3 Pre assembled for S THBs S TMBs includes clamp for mast mounting Full Cross Arm M CAA 91 5 cm 36 in For use with Onset tripods or masts the full cross arm assures unobstructed wind measurement E NDVI Light Sensor Bracket M NDVI Used to mount 2 PAR sensors and 2 solar radiation sensors for making NDVI measurements Also requires M LBB light sensor bracket Light Sensor Level M LLA of light sensors Smart Sensor Extension Cables S EXT MOxx 2 5 10m 25m 16 ft 33 ft 82 ft cable len
24. temperatures in the most extreme ocean environments Built with a virtually indestructible titanium housing the logger can withstand corrosive salt water and exposure to extreme temperature and pressure at depths of up to 11 000 meters Supported Measurements Temperature Key Advantages Withstands depths up to 11 000 meters 36 080 feet e Extended temperature range 40 to 125 C e Fast readout via direct USB interface e Titanium housing for use in saltwater Minimum System Requirements Software USB cable See pg 35 gt For complete information and accessories please visit www onsetcomp com Memory 43 000 measurements Sample rate 1 second to 18 hours user selectable Battery life 3 years typical factory replaceable Logging 40 to 125 C 40 to 257 F Measurement range j inch Readout 0 to 50 C 32 to 122 F per USB specification Accuracy 0 25 C from 0 to 50 0 45 F from 32 122 s Resolution 12 bit 0 02 25 C 0 04 77 F Response time lt 4 minutes to 90 in water Dimensions 114 x 20 6 mm diameter 4 5 x 0 81 in diameter 6 4 mm 0 25 in mounting hole CE compliant Yes USB cable included with software part BHW PRO CD onseicomp com 28 New HOBO MX2001 Water Level Logger Wireless access to water level and temperature data via Bluetooth Low Energy BLE Onset s HOBO MX2001 is the industry s first water level data logger designed for con
25. 60 to 400 C 436 to 752 F 0 6 C 1 08 F thermocouple probe accuracy 0 02 0 03 260 950 436 to 1 742 F 0 6 1 08 F thermocouple probe accuracy 0 03 C 0 05 F Type R 50 to 1 550 C 58 to 2 822 F 2 2 43 96 F thermocouple probe accuracy 0 08 C 0 15 F Type S 50 to 1 720 C 58 to 3 128 F 2 2 C 3 96 F thermocouple probe accuracy 0 08 C 0 15 F Type B 550 to 1 820 C 1 022 to 3 308 F 2 5 C 4 5 F thermocouple probe accuracy 0 1 C 0 18F Type N 260 to 1 300 C 436 to 2 372 F 1 0 C 1 8 F thermocouple probe accuracy 0 06 C 0 11 F Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 3 onseicomp com HOBO UX90 Loggers Next generation time of use loggers for fast reliable monitoring The award winning HOBO UX90 Series is the industry s lowest cost most comprehensive family of time of use data loggers The new toolbox suite includes LCD display data loggers for measuring motor on off status electronic pulses state changes and occupancy and light use patterns Leveraging patent pending technology UX90 data loggers streamline energy audits and make field deployment fast and reliable Supported Measurements State Pulse Event Runtime Light On Off Motor On Off Occupancy Light Key Advantages LCD di
26. ASE U 4 Compliant The HOBO U Shuttle data transporter provides convenient in field data offload and relaunch of HOBO U series loggers and HOBO Weather Stations Micro Stations and HOBO Energy Logger systems Key Advantages Enables convenient easy data offload from HOBO U Series H21 and H22 data loggers and UX data loggers Base Station required for Optic USB loggers Provides safe transport of data back to a computer Stores data from multiple data loggers Displays logger status including memory battery level and sensor readings for some sensors on some models e CABLE HOBO SHTL and CABLE USBNB included The HOBO U DT 2 U30 Shuttle data transporter provides convenient in field data offload and relaunch of HOBO U30 NRC systems and HOBO Weather Stations H21 Micro Stations and HOBO Energy Logger systems H22 Key Advantages Enables convenient easy data offload from HOBO U30 Series H21 and H22 data loggers Provides safe transport of data back to a computer e Stores data from multiple data loggers Displays logger status including memory battery level and sensor readings for some sensors e CABLE HOBO SHTL and CABLE USBNB included The HOBO Waterproof Shuttle provides convenient readout and relaunching of underwater and outdoor HOBO loggers with an Optic USB interface and is waterproof to 20 meters 66 feet The HOBO Waterproof Shuttle can also be used as a Base Station Key Advantages
27. Compatibility Bluetooth 4 0 or later Bluetooth Low Energy Bluetooth Smart Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 onseicomp com HOBO UX100 Loggers Next generation family of temperature and humidity data loggers The HOBO UX100 Series is Onset s next generation family of data loggers for tracking temperature and relative humidity in indoor environments HOBO UX100 Series offer a dramatic price performance advantage over competitive products by delivering higher accuracy larger measurement capacity and more LCD display features to make environmental data collection faster and easier than ever The loggers provide a variety of features to reduce deployment time and offer new logging modes for recording and displaying more detailed data without extensive post processing or memory use Supported Measurements Temperature Relative Humidity Dew Point Key Advantages Large memory capacity Flexible mounting options Visual high amp low alarm thresholds New Burst and Statistics logging modes User replaceable RH sensors Temp humidity and thermocouple models available Response Time airflow of 1 m s 2 2mph Relative Humidity Range n a 15 to 95 Accuracy n a 3 5 from 25 to 85 Resolution n a 0 07 at 25 C 77 F Response Time airflow of 1 m s 2 2mph 8 minutes to 90 n a 43 seconds to 90
28. ESS Data Loggers PRODUCT CATALOG HOBO MX1101 Temperature Data Logger Bluetooth Low Energy temperature and relative humidity data logger 2 1 Research grade Weather Station NEW The HOBO RX3000 is a research grade data logging weather station that combines greater measurement flexibility and an on board LCD display in a rugged easy to deploy package Award winning HOBO UX90 Series The industry s lowest cost most comprehensive family of time of use data loggers 32 HOBO U26 Dissolved Oxygen Logger Affordable high performance dissolved oxygen monitoring A TT HOBO MX1102 CO2 2 HOBO Pendant 2 NEW HOBO MX2001 data logger Loggers Bluetooth BLE Water Level Logger Low cost data loggin NEW Bluetooth Low Energy solution for CO2 temperature and relative light and more The industry s first BLE water humidity data logger level data logger designed for convenient wireless setup and download from mobile devices Visit us at onsetcomp com to browse our full line of HOBO data loggers shop our online store and download material from our Data Logger Resources Library onseicomp com Product Measurements Page HOBO MX1101 Logger temperature relative humidity dew point 1 HOBO MX1102 Logger CO temperature relative humidity dew point 2 HOBO UX100 Loggers temperature relative humidity dew point 3 HOBO UX90 Loggers state pul
29. MX Series loggers HOBOmobile is designed to enable communication between a Bluetooth Smart mobile phone or tablet and the HOBO series data loggers You can configure and start the data logger download the recorded data and store and analyze the data The HOBOmobile app is a free download See pages 1 2 for more details 4 Download the App Store ANDROID APP ON HOBOmobile for Android currently M le supports MX1101 only Support for Goog e play MX1102 coming soon Key Advantages Communicate to HOBO MX data loggers using Bluetooth Smart with no internet connection required e Set data logger s name password logging rate alarm threshold and start amp stop time Configure and clear audible alarms Page the data logger Export and share data as CSV TXT XLSX or HOBO files Measure and log temperature and relative humidity sensitive environments Warehouses and Data centers and Museums archives Commercial Manufacturing Hospitals storage facilities high tech and libraries office buildings facilities and and labs environments testing labs If CO2 temperature and humidity management are critical in your facility do it faster and easier than ever with the new Bluetooth Smart enabled HOBO MX Series Data Loggers Without connecting anything or even coming into physical contact with your data logger you can set up the logger check its status page to locate it and read out your data to b
30. Water Level Loggers one 13 foot for barometric pressure Y and one 13 foot 30 foot or 100 3 foot HOBOware Pro software and a a HOBO Waterproof Data Shuttle Software Base Station Coupler with coupler The Starter Kit includes See pg 35 Seepg45 a HOBO Water Level Logger HOBOware Pro Software and an Optic USB Base Station Available in ua 13 foot 30 foot and 100 foot depths Starter Kit Minimum System Requirements gt For complete information and accessories please visit www onsetcomp com HOBO Water Level Specifications Range 0 4 m 0 13 ft 0 9 m 0 30 ft 0 30 m 0 100 ft 0 76 m 0 250 ft 9 0 145 0 21 0 207 0 30 0 400 0 58 0 850 0 123 69 to 145 kPa 69 to 207 kPa 69 to 400 kPa 69 to 850 kPa 32 to 104 F 10 21 psia 10 30 psia 10 58 psia 10 123 psia Water Level Accuracy 0 3 cm 0 01 ft 0 5 cm 0 015 ft 1 5 cm 0 05 ft 3 8 cm 0 125 ft Typical Error 0 075 FS 0 05 FS 0 05 FS 0 05 FS Resolution 0 14 cm 0 005 ft 0 21 cm 0 007 ft 0 41 cm 0 013 ft 0 87 cm 0 028 ft 310 kPa 45 psia 500 kPa 72 5 psia 1200 kPa 174 psia 18 60 ft depth 40 8 m 134 ft depth 112 m 368 ft depth Temperature Specifications all models Range 20 to 50 C 4 to 122 F Accuracy i037 20 C t 0 677 068 E 0 44 from 0 to 50 C 0 79 from 32 to 122 F Resolution 10 bit
31. aphing and analysis software package for HOBO data loggers It allows you to view graph and analyze data with point and click simplicity You can easily set up your application in a matter of minutes quickly read out and plot data and export to spreadsheets for further analysis Standard Features HOBOware Pro Features Simple menus for fast easy logger setup and readout e Time saving tools for fast setup and readout Scaling to real world engineering units Advanced plotting tools for more precise data analysis Presentation quality graphs Access to Data Assistants for post processing data Easy export of data files to text format Free download HOBOware features comparison HOBOware HOBOware Pro Download HOBOware today at Support for all HOBO data loggers onsetcomp com Quickly generate presentation quality graphs Copy amp paste series Or download your free 30 day Merge data files trial of HOBOware Pro From Save modified graphs as projects setup to analysis no other data Easy data export to XLS CSV amp TXT files logger software can compare Linear amp Pulse Scaling Data Assistants to the power and simplicity of Time saving tools for fast setup readout amp export HOBOware Pro Data assistants for post processing Dissolved Oxygen Conductivity Water Level Growing Degree Days Grains per Pound amp kWh Ability to create pie charts Crop a series to a specific ti
32. ater Level Sensor End 76m 250 MX2001 04 Ti S MX Water Level Sensor End 4m 13 V MX2001 01 Ti S MX Water Level Sensor End 9m 30 U12 015 ORING E O ring kit EPDM V U12 015 ORING V O ring kit Viton H8X4 BK Replacement parts kit V HUM RHPCB 1 RH sensor v HUM RHPCB 2 RH sensor includes S THB V V V HUM RHPCB 3 RH sensor for serial 5 lt 9847173 HUM RHPCB 3A sensor for serial 5 gt 9847173 DESICCANT1 Desiccant 25 ea for UA amp U23 V V DESICCANT2 Desiccant 25 ea submersible cases DESICCANT5 Desiccant 25 ea for UA 003 64 DESIC PACK Desiccant 2 ea for U12 008 V 85 DESICCANT6 Desiccant pack for HOBO Micro Station V UA PARTSKIT Parts kit for UA loggers HUM RHCAP2 RH cap kit 5 ea includes S THB V CABLE TEMP RH Sensor cable for ZW loggers V CABLE U23 002 Sensor cable U26 RDOB 1 Replacement DO Sensor Cap V Ja T m ype aNG I IT D DDDDDDDEEDDDDDN gt 2 Temp only NIST SETUP NIST traceable setup logger V V v V vV V V V v NIST TEMP POINT NIST per point channel v8 EN EU V vV V 32 E E Temp amp RH RH NIST ONEPOINT One degree Temp amp RH certification V V RH NIST THREEPOINT Three degree Temp amp RH certification V vV V V V onsetcomp com 44 MN Data Shuttles Base Stations 45 HOBO U Shuttle U DT 1 HOBO U30 Shuttle U DT 2 HOBO Waterproof Shuttle U DTW 1 HOBO Base Station B
33. city VOC 4 20mA AC current 13 AC voltage Amp hour Amps compressed air flow DC current DC voltage differential pressure gauge pressure kW kWh power factor pulse input volt Amp reactive volt Amp reactive hour volt Amps volts water flow watt hours watts HOBO Energy Logger temperature relative humidity dew point 4 20mA AC Current AC voltage air velocity Amp hour 14 carbon dioxide compressed air flow DC current DC voltage differential pressure gauge pressure kilowatt hours kilowatts power factor pulse input VOC volt Amp reactive volt Amp reactive hour volt Amps water flow watt hours watts wind HOBO Pro v2 Loggers temperature relative humidity dew point 15 Rain Gauge rainfall temperature 16 HOBO Pendant Event temperature event rainfall 1 HOBO Pendant acceleration tilt motion 18 HOBO U12 Outdoor Industrial temperature 4 20mA 0 2 5 VDC see HOBO U12 Industrial data logger U12 008 at onsetcomp com HOBO Weather Stations 19 20 HOBO RX3000 Weather Station temperature relative humidity dew point solar radiation PAR rainfall wind speed wind direction 21 22 soil moisture barometric pressure leaf wetness 4 20mA voltage input pulse input HOBO U30 NRC Weather Station barometric pressure leaf wetness light intensity PAR pulse input rainfall relative humidity soil 23 moisture solar radiation temperature wind speed amp direction 4 20mA voltage input HOBO Micro Sta
34. curacy Battery Life Dimensions Operating Range CE Compliant Thermocouple probes sold separately Type J Type K Type T Type E Type R Type S Type B Type N Internal Temperature 20 to 70 C 4 to 158 F 20 2156 from 0 to 50 0 38 F from 32 to 122 0 024 C at 25 C 0 04 F at 77 F lt 0 1 C 0 18 F per year Logger 1 second to 18 hours Normal Burst Statistics Wrap when full or stop when full 1 minute per month at 25 C 77 F 1 year typical with logging rate of 1 minute and sampling interval of 15 seconds or greater user replaceable 2 AAA 10 8 x 5 41 x 2 54 cm 4 25 x 2 13 x 1 in Logging 20 to 70 C 4 to 158 F 0 to 95 RH non condensing Yes Range Accuracy Resolution 210 to 760 C 346 to 1 400 F 260 to 1 370 C 436 to 2 498 F 260 to 400 C 436 to 752 F 260 to 950 C 436 to 1 742 F 50 to 1 550 C 58 to 2 822 F 50 to 1 720 C 58 to 3 128 F 60 to 1 820 C 1 022 to 3 308 F 260 to 1 300 C 436 to 2 372 F 0 6 C 1 08 F thermocouple probe accuracy 0 7 C 1 26 F thermocouple probe accuracy 0 6 C 1 08 F thermocouple probe accuracy 0 6 C 1 08 F thermocouple probe accuracy 2 2 C 3 96 F thermocouple probe accuracy 2 2 C 3 96 F thermocouple probe accuracy 2 5 4 5 F thermocouple probe accuracy 1 0 C 1 8 F thermocouple probe accuracy 0 03 C 0 06 F
35. e Connect with HOBOlink to upload configuration changes and latest readings Wide range of measurements The measurement possibilities are nearly endless with the RX3000 Station You can configure up to 15 channels of plug and play Smart Sensors and add modules for up to 8 analog sensors And the station can power external sensors requiring 12 volt excitation power extending the range of possible measurements Requires paid data plan 21 onseitcomp com Reliable field proven performance The HOBO RX3000 features a field proven double weatherproof enclosure designed for long term use even in the harshest environments Critical system electronics are sealed in the unit s secondary enclosure and weathertight sensor cable seal keeps moisture out Smart Sensor Connectors Maximum Number of Sensors Smart Sensor Cable Length Module Slots Fastest Logging Rate Memory Alarm notification latency Environmental Rating Operating Range Power Battery Life Size Weight Communications CE Compliant Sooo HOBO RX3000 Remote Weather Station Gore vent keeps excess moisture out Strong fasteners ensure tight seal Tamper resistant padlock loops Strong Polycarbonate PBT blend housing HT 820 high grade UV amp high temp resistant silicone gasket Convenient plug and play operation Simply plug in a Smart Sensor and the RX3000 Station will recognize it and begin taking m
36. e for high speed reliable data offload e Easy to replace DO sensor cap lasts six months Software Base Station See 35 See pg 45 Coupler For complete information and accessories please visit www onsetcomp com Sensor Type Measurement Range Calibrated Range Accuracy Resolution Response time DO Sensor Cap Life Operating Temperature and Measurement Range Temperature Accuracy Temperature Resolution Response Time Memory Logging Rate Time Accuracy Battery Maximum Depth Dimensions CE Compliant Dissolved Oxygen Optical 0 to 30 mg L 0 to 20 mg L 0 to 35 32 to 95 F 0 2 mg L up to 8 mg L 0 5 mg L from 8 to 20 mg L 0 02 mg L To 90 in less than 2 minutes 6 months cap expires 7 months after initialization Temperature 5 to 40 C 23 to 104 F non freezing 0 2 0 36 0 02 0 04 F To 90 less than 30 minutes Logger 21 700 sets of DO and temperature measurements 1 minute to 18 hours 1 minute per month at 25 C 77 F 3 6 V lithium battery factory replaceable life 3 years at 1 minute logging 100 m 328 ft 39 6 mm diameter x 266 7 mm 1 56 in diameter x 10 5 in Yes Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details Coupler included with HOBO Base Station or HOBO Waterproof Shuttle onsetcomp com 34 a HOBOware HOBOware Pro Graphing and analysis software HOBOware is Onset s flagship setup gr
37. e shared It s incredibly easy for anyone to use and leverages the tools we all have in our back pockets and backpacks our phones and tablets Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 onsetcomp com 36 HOBOnode Manager Powerful network management software for HOBO ZW Series Data Loggers HOBOnode Manager a component of HOBOware Pro lets you view real time energy and environmental data receive alarm notifications and manage and view your entire HOBO ZW wireless sensor network It offers a range of convenient data access options and the ability hi kk e to export your data to Microsoft Excel and other M e t FR programs See page 14 for more details Key Advantages Easy network setup and monitoring Real time graphing Easy alarm setup Network Map feature for visual representation of all nodes and network connections 0 Q 0 WmWemme 0 0 0 0 0 0 0 0 0 0 00 e REN _ 45 ole iP xol Li VU WC ER 1 E BRA i r TIE rm p am mL E E View Real Time Plots Easy Alarm Setup Automated Data Delivery In the plots window you can view Easily config
38. easurements No need for programming or complicated wiring 10 up to 15 data channels some sensors use more than one data channel 18 when 2 Analog Modules are configured in the station 100 m 328 ft maximum 2 for optional Analog or Relay module see manual for detailed module specification 1 second 1 second 1 minute 32 MB 2 million measurements Logging interval plus 2 4 minutes typical Weatherproof enclosure NEMA 4X 40 to 60 C 40 to 140 F Onset solar panel AC charger or user provided external power supply is required Typical 3 5 years 4 Volt 10 AHr rechargeable sealed lead acid 18 6 x 18 1 x 11 8 cm 7 3 x 7 1 x 4 7 in 2 2 kg 4 85 Ib GSM GPRS EDGE Quad band 850 900 1800 1900 MHz UMTS HSPA Five band 800 850 900 1900 2100 MHz RJ45 100BaseT IEEE 802 11 b g n Yes AC power adapter or solar panel required See page 44 For more details please visit onsetcomp com or call us at 1 800 564 4377 onsetcomp com 22 n HOBO U30 NRC Weather Station Research grade data logging weather station This rugged weather station is one of Onset s most durable outdoor environmental monitoring solutions Users can easily configure the HOBO U30 NRC Weather Station to fit their application needs Use up to 15 channels to collect environmental data and then upload to HOBOware Pro software for expert analysis Supported Measurements Barometric Pressure Leaf Wet
39. f previous models a deployment friendly LCD and flexible support up to four external sensors for measuring temperature current CO2 voltage and more Supported Measurements Temperature 4 20mA AC Current AC Voltage Air Velocity Carbon Dioxide Compressed Air Flow DC Current DC Voltage Gauge Pressure Kilowatts Volatile Organic Compound Key Advantages Twice the accuracy over previous models 16 bit resolution Flexible support for a wide range of external sensors LCD confirms logger operation and displays near real time measurement data Provides minimum maximum average and standard deviation logging options On screen alarms notify you when a sensor reading exceeds set thresholds e Stores 1 9 million measurements for longer deployments between offloads Minimum System Requirements Software USB cable See pg 35 gt For complete information and accessories please visit www onsetcomp com Memory 1 9 Million Logging Rate 1 second to 18 hours user selectable Logging Modes Normal Burst Statistics Memory Modes Wrap when full or stop when full Time Accuracy 1 minute per month at 25 C 77 F Battery Life 1 year typical with logging rate of 1 minute and sampling interval of 15 seconds or greater user replaceable 2 AAA Dimensions 10 8 x 5 41 x 2 54 cm 4 25 x 2 13 x 1 in Operating Range Logging 20 to 70 C 4 to 158 F 0 to 95 RH non condensing Accuracy 0 1 mV 0 1 of readi
40. gths available Use individually or connected together to optimize sensor placement A weatherproof housing is required for outdoor connections S EXT CASE2 100 meters per data logger onsetcomp com Purchase one for use on any number Network cable length limited to 20 NEW RX3000 Remote Weather Station Research grade weather monitoring with plug and play convenience The HOBO RX3000 is a research grade data logging weather station that combines greater measurement flexibility and an on board LCD display in a rugged easy to deploy package Key Advantages Cloud based data access Plug and play operation Flexible support for a broad range of sensors LCD display for easy field deployment Alarm notifications via text email Rugged double weatherproof enclosure Rp reni Supported Measurements Temperature Relative Humidity Dew Point Solar Radiation PAR Rainfall Wind Speed Wind Direction Soil Moisture Barometric Pressure Leaf Wetness 4 20mA Voltage Input Pulse Input am Oma agi Software Data Power Sensor See pg 35 source See pg 39 Minimum System Requirements Confirm signal strength at the site Deployment Friendly Receive immediate notification of sensor or system problems On board LCD display helps you confirm system operation sensor connections cellular signal strength and other parameters before leaving the deployment sit
41. high accuracy conductivity data in freshwater environments for applications such as environmental impact monitoring stormwater management and water quality studies The HOBO U24 002 C model is for saltwater environments with relatively small changes in salinity 35 000 uS cm such as saltwater bays or to detect salinity events such as upwelling rainstorm and discharge events This logger can also be used to gather salinity data for salinity compensation of HOBO U26 Dissolved Oxygen logger data Note This logger is not intended for monitoring salinity levels in waters with widely changing salinities as it can have significant measurement error and drift in those environments Supported Measurements Conductivity Salinity Temperature Minimum System Requirements Y Key Advantages a Non contact capacitive sensor provides long life Software Base Station Coupler Easy access to sensor for cleaning and shedding air bubbles See 35 See pg 45 e Pro software provides compensation for fouling using calibration points from the start and end of each deployment Optical interface provides high speed reliable data offload in wet environments e Compatible with HOBO Waterproof Shuttle for easy and reliable data retrieval gt For complete information and accessories please visit www onsetcomp com 18 500 temperature and conductivity measurements when using one conductivity range 14 400 oer sets of measuremen
42. hole 1 25 in diameter x 6 5 74 in hole CE compliant Yes HOBO Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details Coupler included with HOBO Base Station or HOBO Waterproof Shuttle 33 onseicomp com HOBO Dissolved Oxygen Logger Affordable high performance dissolved oxygen monitoring The HOBO U26 Dissolved Oxygen Logger measures concentrations of dissolved oxygen in lakes streams rivers estuaries and coastal waters Used by aquatic biologists hydrologists and other research professionals to monitor water quality the U26 is ideal for climate change and environmental impact studies as well as ecological and oceanographic research The HOBO U26 combines the high accuracy robust performance of industry leading RDO Basic Rugged Dissolved Wi Oxygen sensor technology with an easy to maintain design all at a fraction of the cost of other monitoring options Supported Measurements Dissolved Oxygen Temperature Minimum System Requirements QA m Key Advantages e Affordable high performance DO monitoring with 0 2 mg L accuracy Optical DO sensor technology for long lasting calibration less maintenance e Software corrects for measurement drift from fouling provides salinity adjusted DO concentration and percent saturation Salinity adjustment requires salinity meter reading or data logger file Percent saturation requires barometric pressure data file Optic USB interfac
43. ifferential Pressure Gauge Pressure Kilowatt Hours Kilowatts Power Factor Pulse Input Volatile Organic Compound Volt Amp Reactive Volt Amp Reactive Hour Volt Amps Water Flow Watt Hours Watts Wind Key Advantages Minimum System Requirements e Records up to 15 channels Provides 12v excitation for third party sensors Pre configured Smart Sensors for fast setup Signal conditioning modules retain configurations until you change them Software Interface Sensor providing plug and play convenience for commonly used sensors See 35 Cable See pg 39 Flexible power options include battery operation or AC power adapter e Works with Onset s E50B2 Power amp Energy Meter to measure Power Factor Reactive Power Watt Hours and more For complete information and accessories please visit www onsetcomp com Memory Operating Range Sensor Inputs Communication Logging Interval Sensor Excitation Battery Life Battery Type External Power Time Accuracy Dimensions CE Compliant 512K nonvolatile flash data storage 20 to 50 C 4 to 122 F with alkaline batteries 40 to 60 C 40 to 140 F with lithium batteries 6 RJ 12 Smart Sensor jacks plus 3 FlexSmart module slots RS 232 via 3 5 mm serial port 1 second to 18 hours user specified interval 12 V DC at 200 mA total with user programmable warm up time on a per channel basis 1 year typical 8 standard AA alkaline batteries included Supp
44. me frame Subset Statistics Tool for details within a time frame 21 CFR Part11 Compliance Data Shuttle support HOBOnode manager to support ZW Data Nodes e THE Free Download System Requirements e PC Windows 8 Windows 7 Pro Ultimate and Home Premium Windows 10 Pro Ultimate and Home Premium e Windows 7 Enterprise Note While HOBOware has been modified to work on Windows 7 Enterprise there may be local configurations of that operating system that will not work with HOBOware e Mac OS X Versions 10 9 x 10 10 x and 10 11 x e Java Runtime Environment JRE 1 6 or 1 7 32 bit or 64 bit on Windows Please note that Windows 8 users needing serial logger support must have Java 7 1 7 0_9 or greater Please note that version 1 6 also known as Java 6 is officially supported on OS X only on Intel Core 2 Duo and later processors See the time zone note below e One of the following Internet browsers Safari 6 Microsoft Internet Explorer 10 and 11 as well as the most recent versions of Firefox and Google Chrome e Minimum screen resolution of 1024x768 Recommended screen resolution of 1280x800 or greater particularly for non English users e 256 colors e 1 8 GHz single core CPU 1GM RAM Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 35 onsetcomp com Ic HOBOmobile Easy logger setup and data management software for HOBO
45. ness Light Intensity PAR Pulse Input Rainfall Relative Humidity Soil Moisture Solar Radiation Temperature Wind Speed amp Direction 4 20mA Voltage Input Key Advantages e Rugged double weatherproof tamper proof enclosure e Setup is quick and easy with plug and play sensors e Fast data offload via USB Optional analog inputs with sensor excitation Includes relay that can be activated on user defined alarm conditions Minimum System Requirements Software Power Sensor See 35 source See 39 For complete information and accessories please visit www onsetcomp com Smart Sensor Inputs 5 or 10 Data Channels Maximum of 15 some sensors use more than one data channel Smart Sensor Cable Length 100m 323ft maximum Alarm Relay Can be activated deactivated or pulsed on user defined sensor alarms Logging Interval 1 minute to 18 hours user specified Data Storage Memory 512K bytes local storage in non volatile flash memory Environmental Rating Weatherproof enclosure NEMA 4x Operating Range 40 to 60 C 40 to 140 F see battery life Power An Onset solar panel 3w or 6w or AC adapter is required Battery Life 3 5 years 4 volt 10 AHr rechargeable sealed lead acid Dimensions 17 8 x 11 7 x 19 3 cm 7 0 x 4 6 x 7 6 in Weight 2kg 4lbs 1002 Local Communication USB CE Compliant Yes 23 onsetcomp com E HOBO Micro Station 4 channel weatherproof station for monitoring outdoor environmental condi
46. ng CE Compliant Yes USB cable included with software part BHW PRO CD onsetcomp com 6 HOBO UX120 4 Channel Thermocouple Logger Log type J K T E R S B or N thermocouples The HOBO UX120 Thermocouple Logger is a four channel LCD data logger for measuring and recording temperature in a range of monitoring applications The logger makes it easy and convenient to record temperatures over a broad range 260 to 1820 C and can accept up to four J K T E R S B or N type probes In addition to accepting four thermocouple probes the logger features an internal temperature sensor for logging ambient temperatures further extending the application possibilities Supported Measurements Temperature Key Advantages Easy to view LCD display confirms logger operation and battery status Minimum System Requirements Near real time readout of current temperatures as well as minimum maximum average and standard deviation statistics On screen alarms notify you if temperatures exceed high or low thresholds Large memory capacity capable of storing 1 6 million measurements e Start stop and restart push buttons Software USB cable See pg 35 User upgradeable firmware Note for a single thermocouple input logger please see page 3 For complete information and accessories please visit www onsetcomp com Range Accuracy Resolution Drift Logging Rate Logging Modes Memory Modes Time Ac
47. nt beyond a mobile device for configuring the logger or reading out data This saves considerable time and money Minimum System Requirements HOBOmobile Mobile See pg 36 device Supported Measurements Temperature Relative Humidity Dew Point Key Advantages 4 Download on the App Store Bluetooth Low Energy technology for use with mobile devices No internet access cables or computer required Download data any time from 100 ft away Audible and visual alarms keep you notified of problems Easily share data and graph images for analysis ANDROID APP ON Google play gt For complete information and accessories please visit www onsetcomp com Memory 84 650 Measurements Sampling Rate 1 second to 18 hours user selectable Battery Life 1 year typical with logging rate of 1 minute and sampling interval of 15 seconds or greater user replaceable 2AAA Dimensions Range Accuracy Resolution Response Time Range Accuracy Hysteresis Resolution Response Time CE compliant 3 66 x 8 48 x 2 29 cm 1 44 x 3 34 x 0 9 in Temperature 20 to 70 C 4 to 158 F 0 21 C from 0 to 50 C 0 38 F from 32 to 122 F 0 024 C at 25 C 0 04 F at 77 F 7 30 minutes in air moving 1 m s 2 2 mph Relative Humidity 1 to 95 2 from 20 to 80 at 25 C 77 F 2 RH 0 01 at 25 C 77 F 20 seconds to 90 in air moving of 1 m s 2 2 mph Yes Mobile Device Compatibility 5
48. orts optional 13 6 V DC regulated AC Wall Adapter Connector 0 to 2 seconds for the first data point and 5 seconds per week at 25 C 77 F 15 6 cm x 8 4 cm x 4 6 cm 6 13 in x 3 31 in x 1 81 in Yes USB to Serial interface cable part CABLE PC 3 5 see page 43 onseicomp com 14 99 HOBO Pro v2 Loggers Weatherproof loggers for outdoor temperature and humidity measurements HOBO Pro v2 data loggers are weatherproof loggers that provide high accuracy temperature and relative humidity measurements in a wide range of outdoor environments Supported Measurements Temperature Relative Humidity Dew Point Key Advantages Weatherproof housing for use in outdoor or condensing environments e High accuracy measurements e Replaceable RH sensor provides superior recovery from condensing conditions e Small diameter external sensor versions for measurements in tight spaces Optic USB interface for fast and reliable download Minimum System Requirements Software Base Station Coupler See pg 35 See pg 45 gt For complete information and accessories please visit www onsetcomp com Part number U23 001 023 0022 U23 003 U23 004 Internal Temp RH External Temp RH 2x External Temp Temp External Temp Memory 42 000 measurements Sampling rate 1 second to 18 hours fixed rate or multiple logging intervals Battery life 3 years typical user replaceable 1 2 AA lithium Internal Temperature Measu
49. pg 40 gt For complete information and accessories please visit www onsetcomp com Memory 520 000 measurements 4 000 000 measurements Sampling rate 1 second to 18 hours Battery life 1 year typical user replaceable 2 AA External contact Input Electronic solid state switch closure or logic driven digital signals to 24V Max pulse frequency 120 Hz Max state event runtime frequency mie Resolution Pulse 1 pulse Runtime 1 second State and Event 1 state or event Bits 4 32 bits depending on pulse rate and logging interval Lockout time 0 to 1 second in 100 ms steps Operating Logging 40 to 70 C 40 to 158 F 0 to 95 RH non condensing temperature range Dimensions 11 4 x 6 3 x 3 3 4 5 x 2 5 x 1 3 inches CE compliant Yes USB cable included with software part BHW PRO CD onseicomp com 012 4 Channel Loggers Multi channel energy amp environmental monitoring HOBO 12 data loggers provide flexibility for monitoring up to 4 channels of onset energy and environmental data with a single compact logger They provide TITRE nu 12 bit resolution measurements for detecting greater variability in recorded dm data direct USB connectivity for convenient fast data offload and a 43K Aba measurement capacity Supported Measurements Temperature Relative Humidity Dew Point t 4 20mA AC Current AC Voltage Air Velocity Carbon Dioxide
50. r Type RX3000 030 H21 H22 012 U14 ZW UX90 UX100 UX120 T DCI F900 L O Air Velocity 5 m s long T DCI F900 L P Air Velocity 10 m s long V V V V 900 5 0 Air Velocity 5 m s std V V V V V V T DCI F900 S P Air Velocity 10 m s std Volatile Organic Compound Part number Type RX3000 U30 3 H21 H22 U12 U14 ZW UX90 UX100 UX120 T ION TVOC Volatile Organic Compound Differential Pressure Part number Type RX3000 030 H21 H22 U12 U14 ZW UX90 UX100 UX120 T VER PXU L Differential pressure transducer V T VER PXU X Differential pressure transducer V V V V V V Compressed Air Flow Part number Type RX3000 U30 H21 H22 U12 U14 ZW UX90 UX100 UX120 T CDI 5200 10S Compressed Air Flow Meter V T CDI 5200 20S Compressed Air Flow Meter V V V V V V 1 Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 39 onsetcomp cormi External Sensors by Measurement Gauge Pressure Part number Type T ASH G2 100 Ashcroft gauge pressure T ASH G2 200 Ashcroft gauge pressure T ASH G2 500 Ashcroft gauge pressure Energy Power RX3000 U30 S Bl N S N UX90 UX100 UX120 Part number T VER E50B2 T WNB 3D 240 T WNB 3D 480 T WNB 3Y 208 P T WNB 3Y 208 T VER 8044 100 T VER 8051 300 T VER 8053 800 Type
51. re used around the world in a broad range of monitoring applications from verifying the performance of green buildings and renewable energy systems to agricultural and coastal research Based on Cape Cod Massachusetts Onset has been designing and manufacturing its HOBO data loggers on site since the company s founding in 1981 Dam ee ke ke ee Onset headquarters Cape Cod MA Go to to browse our white papers application stories videos and webinars Copyright 2015 Onset Computer Corporation All rights reserved Onset HOBO HOBOware HOBOlink Pendant are registered trademarks of Onset Computer Corporation Other products and brand names may be trademarks or registered trademarks of their respective owners Patented technology U S Patent 6 826 664 MKT1059 1015 NESEA of Energy Engineers NORTHEAST SUSTAINABLE ENERGY ASSOCIATION onseicomp com HOBO Data Loggers www onsetcomp com
52. reater N A 2 min amp greater 2 min amp greater N A AC adapter Hae Backup AC Power Adapter Battery Backup USB power CAO 40 to Er Temp 40 to 40 to 158 F Analog Temp AU to 70 C 40 to 158 F channels 0 to 40 to70 C Quo 25 VOCLO NIA range 40 to 158 RH 51095 VDCPulse 0to 29 00 C40 to 158 RH 65 535 pulses per 5 VDC RH 5 to 95 RH logging interval Temp 0 21 C Temp 0 21 C Temp 0 21 C Temp 0 21 from 0 to 50 from 0 to 50 C fram 0 to 50 C from 0 to 50 0 38 F from Analog 1 544 0 38 F from Analog Accuracy N A 0 38 F from 0 38 F from 32 to 122 F mV plus 2 of 32 to 122 F 1 544 mV plus N A 32 to 122 32 to 122 2 5 reading RH 2 5 2 of reading RH 2 5 Analog 1 544 Analog 1 544 mV 2 mV 2 Temp 0 02 25s 0 04 F Temp 0 02 C Temp 0 02 C_ Big 72 Del 0 04 F oe my ne RET MES 7 0 04 F 77 F Analog channel ua RH 0 0396 Pulse Channel N A RH 0 0396 0 6 mV i Analog channel 1 pulse Pulse Channel 0 6 mV 1 pulse Range Approx 100 m 300 ft depending on obstructions or interference Dimensions 96 5 x 108 x 28 mm 3 8 x 4 25x 1 1 in CE compliant Yes Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 onsetcomp com 12
53. rement range 40 to 70 40 to 158 F Accuracy 0 21 C over 0 to 50 C x 0 38 F over 32 to 122 F Resolution 12 bit 0 02 25 C 0 04 77 F Stability drift lt 0 1 C 0 18 F per year Relative Humidity U23 001 amp U23 002 only Measurement range 0 to 100 RH 40 to 70 C 40 to 158 F Accuracy 2 5 from 10 to 90 RH typical to a maximum of 3 5 including hysteresis Resolution 12 bit 0 03 External Temperature U23 002 40 to 70 C 40 to 158 F U23 003 amp U23 004 40 to 100 C 40 to 212 F with sensor tip and cable immersion in fresh water up to 50 C 122 F for one year Accuracy 0 21 from 0 to 50 0 36 F from 32 to 122 Resolution 0 02 25 C 0 04 77 F Dimensions Housing measures 10 2 x 3 8 cm 4 0 x 1 5 in CE compliant Yes HOBO Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details 1Coupler included with HOBO Base Station or HOBO Waterproof Shuttle Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 15 onseicomp com _ _ _ _8 8 Rain Gauge Rainfall data logging system The HOBO RG3 data logging rain gauge is a self contained device that includes an integrated data logger with a high qualit
54. rproof To 305 m 1 000 ft Dimensions 3 0 x 4 1 x 1 7 cm 1 2 x 1 6 x 0 68 in mounting bail 4 6 mm 3 16 in diameter hole CE compliant Yes HOBO Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details Coupler included with HOBO Base Station or HOBO Waterproof Shuttle To guarantee accuracy the TidbiT v2 Temp must not be used in condensing environments and water temperatures higher than 30 C 86 F for more than eight cumulative weeks over the life of the logger Frequent or prolonged exposure will lead to measurement drift and eventual failure 25 onseicomp com MN IJI HOBO Water Temp Pro v2 Logger Affordable temperature monitoring for fresh or salt water The HOBO Water Temp Pro v2 data logger features 12 bit resolution and a precision sensor for 0 2 C accuracy over a wide temperature range Designed with a durable streamlined case for extended deployment in fresh or salt water the Water Temp Pro v2 is equipped with an Optic USB interface for data offload in the field even when the data logger is wet Supported Measurements Temperature Key Advantages Research grade measurements at an affordable price Waterproof to 120 meters 400 feet Data readout in less than 30 seconds via fast Optic USB interface Minimum System Requirements 4 m Software Base Station Coupler See pg 35 See pg 45 For complete information and accessories please visit www onsetcomp com
55. s gt For complete information and accessories please visit www onsetcomp com Memory Logging Rate Battery Life Dimensions Range Accuracy Warm up Time Calibration Non linearity Range Accuracy Resolution Response Time Range Accuracy Hysteresis Resolution Drift Response Time CE compliant 84 650 Measurements 1 second to 18 hours 6 months typical with logging and sampling intervals of 5 minutes or slower 6 months or less with logging and sampling intervals faster than 5 minutes while logging user replaceable 4AA 7 62 x 12 95 x 4 78 cm 3 0 x 5 1 x 1 88 inches 0 to 5 000 ppm 50 ppm 5 of reading at 25 C 77 F less than 70 RH and 1 013 mbar 15 seconds Auto or manual to 400 ppm lt 1 of FS Temperature 0 to 50 C 32 to 122 F 0 21 C from 0 to 50 C 0 38 F from 32 to 122 F 0 024 C at 25 C 0 04 F at 77 F 12 minutes to 90 in airflow of 1 m s 2 2 mph Relative Humidity 1 to 70 RH when sensor is enabled non condensing 1 to 90 RH when sensor is disabled non condensing 2 from 20 to 80 typical at 25 C 77 F 2 RH 0 01 at 25 C 77 F lt 1 per year typical CO2 1 minute to 90 in airflow of 1 m s 2 2 mph Temp 12 minutes to 90 in airflow of 1 m s 2 2 mph RH 1 minute to 90 in airflow of 1 m s 2 2 mph Yes Mobile Device Compatibility iOS 8 3 8 4 amp 9 0 or Android 4 4 5 0 5 1 and Bluetooth 4 0 or later Bluetooth
56. se event runtime light on off motor on off occupancy light 4 HOBO UX120 Plug Load Logger AC Current AC Voltage Amps Kilowatt Hours Power Factor Volt Amps Volts Watt Hours Watts 5 HOBO UX120 4 Channel Analog Logger temperature 4 20mA AC current AC voltage air velocity carbon dioxide compressed air flow 6 DC current DC voltage gauge pressure kilowatts VOC HOBO UX120 4 Channel Thermocouple Logger temperature UX120 4 Channel Pulse Logger pulse signals event runtime state AC current AC voltage Amp hour kilowatt hours kilowatts 8 motor on off power factor volt amps watt hours watts volt amp reactive volt Amp reactive hour HOBO U12 4 Channel Loggers temperature relative humidity dew point 4 20mA AC current AC voltage air velocity 9 carbon dioxide compressed air flow DC current DC voltage gauge pressure kilowatts VOC HOBO U12 Stainless Temp Loggers temperature 10 HOBO U14 Loggers temperature relative humidity dew point 11 HOBO ZW Series Wireless Sensors air velocity AC current AC voltage Amp hour C02 compressed air flow DC current DC 12 voltage differential pressure gauge pressure kilowatt hours kilowatts power factor pulse signals temperature relative humidity dew point VOC volt Amp reactive volt Amp reactive hour volt Amps water flow watt hours watts volts Amps 0 10 VDC 4 20mA HOBO RX3000 Remote Monitoring Systems temperature relative humidity dew point C02 air velo
57. splays Time On or On providing instant feedback Auto calibration amp signal strength indicator ensure proper deployment 84 or 346k measurement capacity enables longer deployments e Rare earth magnets Command Strips or mounting tabs for reliable mounting A Software USB cable Flexible logger Start and Stop options See pg 35 e HOBOware Pro allows for easy setup of hundreds of loggers Minimum System Requirements USB cable included with software part BHW PRO CD For the most accurate readings use of Light Pipe UX90 LIGHT PIPE 1 is recommended to eliminate the effects of ambient light See page 44 for more details gt For complete information and accessories please visit www onsetcomp com Memory 84 000 measurements Memory 346 000 measurements INTERNAL SENSOR Maximum state event runtime 1 Hz frequency Light threshold 65 lux 65 lux LED CFL fluorescent HID LED CFL fluorescent HID incandescent Light type incandescent natural natural 2C magnetic Teid gt 40 mGauss at 60 Hz threshold MaximuM SENSO 5 m 15 4 ft 12 m 39 4 ft detection range EXTERNAL INPUT solid state closure or External contact input logic driven voltage solid state closure output Maximum state event runtime 1 Hz frequency Maximum Pulse 50 Hz _ _ _ _ Frequency Battery life 1 year typical user replaceable CR2032 Operating range 20
58. t For complete information and accessories please visit www onsetcomp com E 6 500 temp 52 000 temp 3 500 temp amp light 28 000 temp amp light Sample rate 1 second to 18 hours user selectable Battery life 1 year typical user replaceable CR2032 Water Depth Rating 30 m from 20 to 20 C 100 ft from 4 to 68 F Temperature Measurement range 20 to 70 C 4 to 158 F in air 20 to 50 C 4 to 122 F in water Accuracy 0 53 C from 0 to 50 C 0 95 F from 32 to 122 Resolution 10 bit 0 14 C 25 C 0 25 F 77 F Response time 10 minutes to 90 in airflow of 2 m s 5 minutes to 90 in water Light intensity Range 0 323 000 lumens m2 0 30 000 foot candles lumens ft2 Acceleration Measurement range iw Accuracy 2 5 FS 25 C 77 F Factory calibrated Resolution 8 bit 0 02G Tilt Motion Measurement range 2 5 FS 25 C 77 F Factory calibrated Resolution 8 bit 4 3 90 to 13 0 and 180 Dimensions 5 8 x 3 3 x 2 3 cm 2 3 x 1 3 x 0 9 in CE compliant Yes Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details For more details see page 18 27 onsetcomp com 64 000 accel 32 000 tilt 21 333 motion 100 per second 012 Deep Ocean Temp Logger Water temperature monitoring in extreme ocean environments The 012 Deep Ocean Temperature data logger is designed to track water
59. t adapter 1m S UCD M006 Contact closure pulse input adapter 6m V V V V CABLE 2 5 STEREO Voltage input cable 0 2 5 VDC V V Time of Use Motor On Off Part number Type RX3000 U30 H21 H22 U12 U14 ZW UX90 UX100 UX120 CSV A8 AC current switch V V Water Water Temperature Part number Type RX3000 U30 H21 H22 U12 U14 ZW UX90 UX100 UX120 S TMB M002 12 bit Temp smart 2m cable 9 S TMB M006 12 bit Temp smart 6m cable V V V S TMB M017 12 bit Temp smart 17m cable V V V TMC1 HD Air Water Soil Temp 1 cable V TMC6 HD Air Water Soil Temp 6 cable TMC20 HD Air Water Soil Temp 20 cable V TMC50 HD Air Water Soil Temp 50 cable Weather Field Temperature Part number Type RX3000 U30 H21 H22 U12 U14 ZW UX90 UX100 UX120 S THB M002 12 bit Temp RH smart 2m cable 9 S THB M008 12 bit Temp RH smart 8m cable S TMB M002 12 bit Temp smart 2m cable V V V S TMB M006 12 bit Temp smart 6m cable V S TMB M017 12 bit Temp smart 17m cable V V V TC6 J Type J beaded thermocouple TC6 K Type K beaded thermocouple TC6 T Type T beaded thermocouple 4 TCP6 K12 Type K probe thermocouple ui TMC1 HD Air Water Soil Temp 1 cable V TMC6 HD Air Water Soil Temp 6 cable V TMC20 HD Air Water Soil Temp 20 cable TMC50 HD Air Water Soil Temp 50 cable V TMC6 HC Stainless Steel Temp probe 6 cable
60. t mode Time accuracy 1 minute per month at 25 C 77 F In water ice 20 to 50 C 4 to 122 F In air 20 to 70 C 4 to 158 F Logging interval Operating range Water depth rating 30 m from 20 to 20 C 100 ft from 4 to 68 F Dimensions 5 8 3 3 x 2 8 cm 2 3 x 1 3 x 0 9 in CE compliant Yes HOBO Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details onsetcomp com 18 HOBO Weather Stations Research grade weather monitoring with plug and play convenience HOBO Weather Stations save you time and money by offering plug and play convenience and research grade performance 19 NEW HOBO RX3000 HOBO U30 NRC HOBO 21 002 e 10 Smart Sensor inputs 5 or 10 Smart Sensor inputs 4 Smart Sensor inputs Cloud based data access Optional analog sensor port e Compact low cost e Supports broad range of sensors Built in relay e Improved weatherproof enclosure LCD display e Supports broad range of sensors Supports broad range of sensors Optional analog sensor amp relay Lean more on page 23 Lean more on page 24 modules Lean more on page 21 22 2 d M TPB O Height range 1 72 to 2 13 m 5 6 to 7 ft Mast diameter 4 1 cm 1 63 in Weight 5 8 kg 12 8 165 M GKA Grounding Kit is recommended when using tripods in exposed locations 3 Meter Tripod Kit 2 Meter Tripod Kit also available M TPB KIT M
61. tcomp com or call us at 1 800 564 4377 For USB data logging applications in harsh indoor environments see the 4 channel HOBO 012 Industrial data logger U12 008 at onsetcomp com 9 onsetcomp com U12 Stainless Temp Loggers High accuracy temperature monitoring for challenging process conditions HOBO U12 Stainless Temperature data loggers ideal for food pharmaceutical autoclave and other applications where high accuracy temperature data is critical They can withstand process conditions from pasteurization to flash freezing and washdown 012 Stainless Temperature Logger Supported Measurements Temperature Key Advantages HOBO 012 Stainless Temperature Logger High accuracy extended temperature range with 5 inch Probe Suitable for high pressure applications to 2200 psi Fast readout via direct USB interface Minimum System Requirements Software USB cable See pg 35 For complete information and accessories please visit www onsetcomp com Memory 43 000 measurements Battery life 3 year typical factory replaceable 10 minutes to 90 in airflow of 1 m s 2 25 minutes to 90 in airflow of 1 m s NES EON ENE 3 5 minutes to 90 in water 20 seconds to 90 in water Operating range Logging 40 to 125 C 40 to 257 F Launch readout 0 to 50 C 32 to 122 F per USB specification Range 40 to 125 C 40 to 257 F 0 25 from 0 to 50 C Accurac
62. te information and accessories please visit www onsetcomp com Memory 43 000 measurements Sample rate 1 second to 18 hours recording times up to 1 year Battery life 1 year typical user replaceable 3 AAA alkaline Range Temp 20 C to 50 C 4 F to 122 F Accuracy Temp 0 2 C from 0 to 50 C 0 36 F from 32 to 122 F RH 2 5 from 10 to 90 Resolution 0 03 at 25 C 0 05 at 77 F Data channels Measurement range Accuracy Response time Dimensions CE compliant 0 2 5 to 95 RH non condensing 3 5 RH from 25 to 95 over range of 5 to 55 C 41 to 131 Internal temp sensor e 15 min to 90 in airflow of 1 m sec External temp Sensor 5 min in airflow of 1 m sec External RH Sensor 5 min in airflow of 1 m sec with protective Internal RH sensor e 2 min to 90 in airflow of 1 m sec 125 x 92 x 31 mm 4 9 x 3 6 x 1 2 in Yes Sensor required for U14 002 only 1USB cable included with software part BHW PRO CD 2 Note Temp amp RH NIST certification services available for this product Please visit onsetcomp com or call us at 1 800 564 4377 onsetcomp com HOBO ZW Series Wireless Sensors Monitor and transmit real time building performance data wirelessly HOBO ZW Series wireless data nodes provide centralized monitoring of energy and environmental conditions in buildings Supported Measurements Air Velocity AC Current AC Voltage Amp Hour
63. test Logging Rate 1 second 1 second 1 minute Memory 32 MB 2 million measurements Alarm notification latency Logging interval plus 2 4 minutes typical Environmental Rating Weatherproof enclosure NEMA 4X Operating Range 40 to 60 40 to 140 F Power Onset solar panel AC charger or user provided external power supply is required Battery Life Typical 3 5 years 4 Volt 10 AHr rechargeable sealed lead acid Size 18 6 x 18 1 x 11 8 cm 7 3 x 7 1 x 4 7 in Weight 2 2 kg 4 85 Ib GSM GPRS EDGE Quad band 850 900 1800 1900 MHz UMTS HSPA Five band 800 850 900 1900 2100 MHz Communications RJ45 100BaseT IEEE 802 11 b g n CE Compliant Yes Requires paid data plan power adapter or solar panel required See page 44 For more details please visit onsetcomp com or call us at 1 800 564 4377 13 onsetcomp com HOBO Energy Logger Multi channel energy data logging system The HOBO Energy Logger multi channel data logger is a modular reconfigurable data logging system for energy and industrial monitoring applications The 15 channel system enables energy and facility management professionals to quickly and easily solve a broad range of monitoring applications without having to purchase a toolbox full of data loggers Eee Supported Measurements Temperature Relative Humidity Dew Point 4 20mA AC Current AC Voltage Air Velocity Amp Hour Carbon Dioxide Compressed Air Flow DC Current DC Voltage D
64. tion temperature relative humidity dew point wind speed wind direction rainfall soil moisture solar 24 radiation PAR barometric pressure leaf wetness 4 20mA voltage input pulse input light intensity TidbiT v2 Temp Logger temperature 25 HOBO Water Temp Pro v2 Logger temperature 26 HOBO Pendant Loggers temperature light intensity tilt acceleration 20 HOBO U12 Deep Ocean Temp Logger temperature 28 HOBO Water Level Loggers water level barometric pressure pressure absolute differential pressure temperature 29 32 HOBO Conductivity Loggers conductivity salinity temperature 33 HOBO Dissolved Oxygen Logger dissolved oxygen temperature 34 HOBOware HOBOware Pro 35 HOBOmobile 36 HOBOnode Manager 9f HOBOlink 38 External Sensors by Measurement 39 42 Accessories 43 44 Data Shuttles Base Stations 45 46 onseicomp com HOBO MX1101 Logger Bluetooth Low Energy temperature and relative humidity data logger Onset s HOBO MX1101 is a Bluetooth Low Energy BLE data logger that measures and transmits temperature and relative humidity data wirelessly to mobile devices via BLE Y rj ih technology The self contained wireless data logger which works with Onset s free HOBOmobile app for logger setup and data management enables users to access data anytime from their mobile device over a 100 foot range It communicates instantly and enables you to cut the cord by requiring no dedicated equipme
65. tions The HOBO Micro Station offers reliable monitoring performance at industry leading prices Designed for stand alone data logging applications the 4 channel HOBO Micro Station accepts Onset s full suite of plug and play Smart Sensors and is battery powered for up to one year Supported Measurements Temperature Relative Humidity Dew Point Wind Speed Wind Direction Rainfall Soil Moisture Solar Radia tion PAR Barometric Pressure Leaf Wetness 4 20mA Voltage Input Pulse Input Light Intensity Key Advantages e Improved weatherproof enclosure for harsh environments Compact and low cost with 4 sensor inputs Up to 2 DC voltage or 4 20mA input adapters Minimum System Requirements Software Interface Sensor See pg 35 Cable See pg 39 For complete information and accessories please visit www onsetcomp com Memory 512K non volatile flash data storage Operating Range 20 to 50 C 4 to 122 F with alkaline batteries 40 to 70 C 40 to 158 F with lithium batteries Sensor Inputs Up to four Smart Sensors including multiple parameter sensors Communication RS 232 via 3 5 mm serial port Logging Interval 1 second to 18 hours user specified interval Time Accuracy 0 to 2 seconds for the first data point and 5 seconds per week at 25 C 77 F 1 year typical up to 10 sensors w 10 minute or longer logging interval Banery Eite 4 AA alkaline batteries included Dimensions 8 9 cm H x 11 4 cm D
66. to 122 a solar radiation shield is required for temperature measurements in sunlight 0 14 C at 25 C 0 25 F at 77 F Airflow of 2 m s 4 4 mph 10 minutes typical to 90 1 second to 18 hours user selectable 7 1 x 3 3 x 2 3 cm 2 8 x 1 3 x 0 9 in Cable 1 8 m 6 ft Yes HOBO Base Station or HOBO Waterproof Shuttle required See pages 45 46 for more details onseicomp com HOBO Pendant Measures acceleration tilt and motion Measure 3 dimensional motion such as sports activity or medical therapy compliance with the HOBO Pendant G data logger With this logger users can measure acceleration and angular displacement in 1 2 or 3 axes Use this data to monitor activity and improve performance Supported Measurements Acceleration Tilt Motion Key Advantages Low cost acceleration and tilt measurement Waterproof housing for wet or underwater use e Data readout in less than 30 seconds via fast Optic USB interface 080H ry Minimum System Requirements 2 Software Base Station See pg 35 See 46 For complete information and accessories please visit www onsetcomp com Memory 64K bytes approximately 21 8K combined x y and z axis readings or events Battery life 1 year typical user replaceable CR2032 Resolution 0 025 g 0 245 m s 0 8 ft s 1 second to 18 hours 12minutes 15 seconds in Normal mode 0 01 seconds 100 Hz to 0 99 seconds 1 01 Hz in Fas
67. ts when using both conductivity ranges 64 kbytes Conductivity Calibrated Low Range 0 to 1 000 5 Low Range 100 to 10 000 uS cm Measurement Ranges Full Range 0 to 10 000 uS cm High Range 5 000 to 55 000 uS cm Conductivity Calibrated Range 5 to 35 C 41 to 95 F Temperature Range Low Range 3 of reading or 50 uS cm Specific Conductance Accuracy Low Range 3 of reading or 5 uS cm whichever is greater in Calibrated Range using Conductivity As Full Range 3 of reading or 20 uS cm High Range 596 of reading in waters within sistant and Calibration Measurements whichever is greater a range of 53 000 uS cm waters with greater variation can have substantially greater error Conductivity Resolution typical 1 uS cm 2 uS cm S Conductivity Drift Less than 396 sensor drift per year died ot pol DONIN eae omy start amp end point calibration to compensate Temperature Accuracy in Calibrated Range OECD 24m Temperature Resolution 0 01 C 0 02 F Response Time 1 second to 90 of change in water Measurement and Operating Range 0 to 36 C 32 to 97 F non freezing 2 to 36 C 28 to 97 F non freezing Sample rate 1 second to 18 hrs fixed or multiple rate sampling with up to 8 user defined sampling intervals Time Accuracy 1 minute per month Battery 3 6 Volt lithium battery life 3 years at 1 minute logging typical Maximum Depth 70 m 225 ft Dimensions 3 18 cm diameter 16 5 cm with 6 3 mm mounting
68. ure both sensor and Get your data forwarded to FTP up to 20 sensor data points in real system alarms Get notified via text site or email address at regular in time all at once message or email when conditions tervals Easy integration with third exceed set thresholds party programs 37 onseicomp com 115 HOBOlink Web Based Display Readout Powerful web based access to HOBO RX3000 Remote Monitoring Systems Key Advantages Get 24 7 web access to your data Access your data via web browser Customize your data display e Verify RX3000 system status remotely e Set up and manage alarm notifications over the web e Schedule automated delivery of data files Analyze data faster with custom export capabilities Web based configuration HOBOlink allows you to easily configure sensors logging alarm notifications relay activations and more Get notified HOBOlink will send an email or a text message to your phone when conditions exceed set thresholds Multiple levels of alarms and actions can be set for each sensor onseicomp com HOBOlink is a web enabled software platform designed for HOBO RX30000 Remote Monitoring Systems This data logger software allows you to easily access current and historical data set alarm notifications and relay activations and manage and control your HOBO RX3000 web based data logging systems See pages 15 23 and 24 for more details Monument Beach
69. venient wireless setup and download from mobile devices via Bluetooth Low Energy BLE technology The logger dramatically simplifies and lowers the cost of field data collection by providing wireless access to high accuracy water level and temperature measurements right from a mobile phone or tablet Supported Measurements Water Level Water Temperature Absolute Pressure Barometric Pressure Differential Pressure Key Advantages Wireless data offload to mobile devices via BLE Direct read cable connects sensor to top end logger Minimum System Requirements Integrated barometric pressure sensor enables direct water 4 Download the App Store level readout e Reference water level can be entered at start of deployment e Use HOBOmobile for setup data viewing and data sharing HOBOmobile Mobile Cable The cable includes Kevlar strength member Seepg36 device 44 Powered by two user replaceable AA batteries Normal multi rate and burst logging modes Durable ceramic sensor Available with stainless steel or titanium sensor ends Accurate Data Easily Onset s HOBOmobile app a free download from iTunes makes it a snap to configure HOBO MX2001 loggers and manage the collected data You can view data in graphs check the operational status of loggers configure alarm notifications and share data files Aug mm a Mer Fr EDT
70. visual diagnostics for easy deployment Factory calibrated see user s manual for details Minimum System Requirements Software USB cable See pg 35 For complete information and accessories please visit www onsetcomp com RMS Voltage Accuracy RMS Current Accuracy Active Power Accuracy Power Factor Accuracy 0 5 up to 14 Amp continuous up to 1 096 over 14 Amp when equipment being monitored is at 100 duty cycle Power Factor Accuracy 50 02 Drift Up to 0 5 typical within 1 year Memory 4 MB 1 4 million measurements maximum Logging rate 1 second to 18 hours 12 minutes 15 seconds Sampling rate 60 Hz or 16 67 mS single cycle Battery life 2 y S line power 6 months battery only no line power with logging rate of 1 minute or greater operating at Power source Line powered with 0 92 m 3 ft AC power cord or two AAA 1 5 V alkaline batteries user replaceable Resolution 1 Watt Load at 120 V AC 15 Amp mia AA range Logging 5 to 40 C 41 to 104 F 0 to 95 RH non condensing Dimensions 13 97 x 7 62 x 4 7 5 ci 5 x 3 x 1 87 in CE Compliant Yes USB cable included with software part BHW PRO CD onseicomp com HOBO UX120 4 Channel Analog Logger Flexible accurate 4 channel analog logger The HOBO UX120 006M Analog Logger is a high performance LCD display data logger for building performance monitoring applications As Onset s highest accuracy data logger it provides twice the accuracy o
71. which have become a generic name for data loggers in many markets are known for providing the most reliable accurate energy and environmental data under some of the world s toughest environmental conditions World Class Support Many of our new customers are surprised to find that when they call Onset a live person answers the phone Our world class technical service department is staffed by friendly knowledgeable people who listen carefully to your questions and guide you through any challenges that arise Unlike many technology companies Onset offers free technical support for the life cycle of your purchase onseicomp com Simple amp Cost Effective At Onset we realize that the technology skill set of our customers and their technology budgets can vary widely For this reason our products are designed from the ground up with ease of use and affordability in mind Temperature relative humidity monitoring is critical to the preservation of our records Traditional data loggers would have provided the data we needed but we didnt want to spend a lot of time manually retrieving the data throughout the building The wireless data nodes are helping us make sure that our archives are getting the best protection possible Harold Stoehr Network Administrator Washington State Archives About Onset Onset is a leading supplier of data loggers Our HOBO data loggers and weather stations a
72. x 5 4 cm W 3 5 x 4 5 x 2 125 in CE Compliant Yes USB interface cable See page 43 onsetcomp com 24 TidbiT v2 Temp Logger Small durable logger for measuring water temperature Onset s smallest data logger the TidbiT v2 has 12 bit resolution and a precision sensor for 0 2 C accuracy over a wide temperature range It is waterproof to 300 meters 1 000 feet and can be used in a wide range of water temperature monitoring applications Supported Measurements Temperature Key Advantages Onset s smallest temperature logger Waterproof to 300 meters 1 000 feet e Data readout in less than 30 seconds via fast optic USB interface Minimum System Requirements A m Software Base Station Coupler See pg 35 See 45 For complete information and accessories please visit www onsetcomp com Temperature Sensor Operation range 20 to 70 C 4 to 158 F in air maximum sustained temperature of 30 C 86 F in water Accuracy 0 21 C over 0 to 50 C 0 38 F over 32 to 122 F Resolution 0 02 C at 25 C 0 04 F at 77 F Response time 5 minutes in water 12 minutes in air moving 2 m sec 20 minutes in air moving 1 m sec typical to 90 Stability drift 0 1 C 0 18 F per year Logger Real time clock 1 minute per month 0 to 50 C 32 to 122 F Battery 3 Volt lithium non replaceable Battery life 5 years with 1 minute or greater logging interval Memory 42 000 measurements Wate
73. y 0 25 C from 0 to 50 C y 0 45 F from 32 to 122 F 0 45 F from 32 to 122 F Resolution 0 03 C at 25 0 05 F at 77 F at 25 0 05 F at 77 F Logger 17 5 x 101 6 mm 0 69 x 4 00 in Dimensions 17 5 x 101 6 mm 0 69 x 4 00 in Probe 4 x 124 mm 0 16 x 4 90 in CE compliant Yes USB cable included with software part BHW PRO CD onsetcomp com 10 IM UU HOBO U14 Loggers Display record and get notified of temperature and humidity conditions HOBO 14 data loggers display record and provide alarm notifications of temperature and humidity conditions Receive out of range alarm notifications with the optional Auto Dialer or remote Audible Alarm These loggers are well suited for use in manufacturing processing and storage environments where reliable monitoring and documentation of specific temperature and relative humidity conditions are critical Supported Measurements Temperature Relative Humidity Dew Point Key Advantages Real time display of temperature and relative humidity Alarm display and output ensure timely notification of out of range conditions Optional Remote Alarm and Autodialer Choice of two models Internal Temp Humidity or External Temp Humidity sensors Optional protective case for harsh or outdoor environments Fast data offload via USB Minimum System Requirements amp ES USB cable Software Sensor See pg 35 See pg 39 gt For comple
74. y tipping bucket rain gauge The RG3 s logger has a built in temperature sensor and is on a cable so it can be used in an optional radiation shield for logging air temperature Supported Measurements Rainfall Temperature Key Advantages Aluminum housing and 15 4 cm 6 06 in collector ring Field proven design Logger can be moved into an optional radiation shield for logging air temperature Three mounting feet to use on flat level surfaces e Side bracket for mast mounting hose clamps included e Self emptying for continuous rainfall logging Minimum System Requirements Software Base Station See pg 35 See pg 46 For complete information and accessories please visit www onsetcomp com Measurement range Resolution Time stamp resolution Maximum Rainfall rate Battery life Measurement range Events only 16K to 23K events Events and temperature 25K to 30K data points Up to 320 cm RG3 M up to 160 in 0 2 mm RG3 M 0 01 in RG3 1 second 12 7 cm 5 in per hour 1 year typical user replaceable CR2032 Temperature 20 to 70 C 4 to 158 F 2 0 55 6 from 0 to 50 0 95 F from 32 to 122 a solar radiation shield is required for temperature measurements in sunlight Resolution 0 14 C at 25 C 0 25 F at 77 F Sample rate 1 second to 18 hours user selectable Dimensions CE compliant 15 2 cm diameter

Download Pdf Manuals

image

Related Search

Related Contents

IWC-1870 Instruction Manual  Edital Pregão Presencial nº 071/2014  Beispielszenario für die Zutrittskontrolle    JAMO C 80 User's Manual  Canon Speedlite 320EX    取扱説明書 - 株式会社太陽インターナショナル  

Copyright © All rights reserved.
Failed to retrieve file