Home

Installation Manual

image

Contents

1. ERGOTRON User s Guide Zip 12 Charging Wall Cabinet For the latest User Installation Guide please visit www ergotron com User s Guide English Guia del usuario Espanol Manuel de l utilisateur Fran ais Gebruikersgids Deutsch Benutzerhandbuch Nederlands Guida per l utente Italiano Anv ndarhandbok svenska OOOOGEOD 000 DUDU 010 888 61 182 G 00 rev B 04 15 Includes Show amp Stow technology q www ergotron com USA 1 800 888 8458 N Europe 31 0 33 45 45 600 China 400 120 3051 1 of 17 Hazard Symbols Review These symbols alert users of a safety condi tion that demands attention All users should be able to recognize and understand the significance of the following Safety Hazards if encountered on the product or within the documentation Children who are not able to recognize and respond appropriately to Safety Alerts should not use this product with out adult supervision Safety WARNING Because surfaces vary widely and the ultimate mounting method is out of Ergotron s control it is imperative that you consult with appropriate engineering architectural or construction professional to ensure that your Ergotron mounting solution is mounted properly to handle applied loads 2 of 17 Level of Hazard Signal Word NOTE CAUTION Symbol A NOTE indicates important information that helps you make better use of this product A CAUTION indicates either
2. Use the 1 2 13 mm drill bit when drilling into the hollow wall for the anchors Use hollow wall anchors where ever a screw does not get inserted directly into the wood stud W NOTE Use the 3 16 5 mm drill bit when drilling directly into the wood stud WOOD STUD HOLLOW WALL 5 32 Ze 2 m TN G 1 4 20 x 2 62 68 158 173 cm h Insert anchors then attach bracket to wall according to the hole option determined on previous page Verify wall bracket is level before tightening screws 888 61 182 G 00 rev B 04 15 5 7 of 17 lt 5 8 CONCRETE lt 16 mm 24 102mm A Put a mark on the wall 62 68 b Level and secure template to 158 173 cm from floor the wall lining up the chosen mounting holes with the mark 62 68 158 173 cm from floor 62 68 158 173 cm 62 68 158 173 cm A C Dril the top 3 holes then the bottom two holes d 2244 3 8 10 mm SS TE Q 3 1 8 WARNING Mounting holes must be at least 3 1 8 80mm deep and must be located within solid concrete not mortar or covering material If you drill into an area of concrete that is not solid reposition ee mounting holes until both anchors can be fully 62 68 inserted into solid concrete 158 173 cm Insert anchors into holes then attach mounting bracket Verify wall 3X M6 x 70mm bracket is level before tightening screws WARNING Anchors tha
3. HH 7 Zem Es SS Es d 888 61 182 G 00 rev B 04 15 11 of 17 9 Pull out tablet tray and insert tablet FA NOTE Tablet should be positioned so power plug is at top or left side a Slide cable clip off of tablet slot and route cable through clip then reattach cable clip 774 NOTE Leave enough slack in cable to plug into tablet b Plug tablet cables into tablets E NOTE When tablet is removed store unconnected cable in the appropriate tablet slot b 12 of 17 888 61 182 G 00 rev B 04 15 1 1 Tie up excess cable with velcro cable ties NOTE Keep cables away from power system components that might get hot during operation a Attach left cover with 2 screws saved from removal of cover b Open door and attach 3 inside screws saved from removal of left cover 888 61 182 G 00 rev B 04 15 13 of 17 1 3 a Close door and turn lock knob 180 counter clockwise b Lock door by turning key 180 counterclockwise 14 of 17 888 61 182 G 00 rev B 04 15 Tablet Charging To begin charging the tablets plug in the power cord mg The power cord is used to turn the power on and off Charging occurs whenever the power cord is connected to an outlet LED E NOTE The power cord acts as the connect disconnect device switching power on and off The socket outlet shall be installed near the equip
4. potential damage to hardware or loss of data and tells you how to avoid the problem A WARNING indicates either potential for property dam age personal injury or death ELECTRICAL An Electrical indicates an impending electrical hazard which if not avoided may result in personal injury fire and or death CAUTION Make sure the wall mount bracket is level flush and snug to the wall surface DO NOT OVER TIGHTEN THE BOLTS A lt 44 4 Ibs 20 1 kg CAUTION DO NOT EXCEED MAXIMUM LISTED WEIGHT CAPACITY SERIOUS INJURY OR PROPERTY DAMAGE MAY OCCUR 888 61 182 G 00 rev B 04 15 Components g WOOD STUD HOLLOW WALL SS55555 3 16 5 mm 1 2 13 mm CONCRETE DIDILA 3 8 10 mm T REMOVE INTERNAL PACKAGING TEAM H For Your Safety 888 61 182 G 00 rev B 04 15 2 MOUNTING CONSIDERATIONS Space Requirements When mounting to wood stud at least one screw in the upper mounting bracket must be installed in a stud preferably the center hole 35 3 900 mm 7 11 8 6 5 6 152 mm 178 mm 300mm 168mm 4 102mm gt 6 151 mm 3 74 mm ah g BE Mounting Holes 32 75 35 6 831 mm 905 mm 62 68 158 173 cm Recommended Mounting Height Above Floor Individual tablet or chromebook weight Individual dimensions including cover lt 11 9 302 mm YS E lt 8 5 lt 3 Ibs 215 mm 1 3
5. 6 kg J S V A lt 1 25 mm 3 _ WOOD STUD HOLLOW WALL lt 5 8 4 lt 16 mm je 40f 17 x CONCRETE gt 4 102mm lt 5 8 lt 16mm 888 61 182 G 00 rev B 04 15 HOLLOW WALL a First Choose a Hole Option The stud can be located at one of five mounting holes on the top bracket While the first option center hole of bracket is recommended you should consult with a construction professional to confirm which method is best suited for your particular situation After you decide on a Hole Option follow attachment instructions on the following page Hole Option 1 RECOMMENDED Center Hole in Stud Hole Option 2 Extreme Left Hole in Stud Hole Option 3 Hole Option 4 Hole Option 5 Extreme Right Hole in Stud Middle Right Hole in Stud Middle Left Hole in Stud 61 182 G B 04 1 888 61 18 00 rev 04 15 5 of 17 HOLLOW WALL b Find stud and draw a mark C Put a mark on the stud 62 68 158 173 cm from floor 62 68 158 173 cm d Place template on wall lining up the ea Level and secure template chosen hole with the stud and the to wall mark 62 68 158 173 cm from floor 62 68 158 173 cm 6 of 17 888 61 182 G 00 rev B 04 15 WOOD STUD HOLLOW WALL 1 Drill the three holes for the top bracket that correspond with the hole option determined on previous page f 2 Drill the bottom two holes
6. NDLIEN HVET VOCI A 16 of 17 888 61 182 G 00 rev B 04 15 service and Warranty For service and warranty visit www ergotron com For local customer care phone numbers visit http contact ergotron com www ergotron com NOTE When contacting customer service MADE IN CN reference the serial number 12 345 67 8 AO AY A 1234567 1234 2015 Ergotron Inc All rights reserved Americas Sales and ERGOTRON Corporate Headquarters EMEA Sales St Paul MN USA Amersfoort The Netherlands While Ergotron Inc makes every effort to provide accurate and complete information on the installation 800 888 8458 31 33 45 45 600 and use of its products it will not be held liable for any editorial errors or omissions including those 1 651 681 7600 www ergotron com made in the process of translation from English to another language or for incidental special or www ergotron com info eu ergotron com consequential damages of any nature resulting from furnishing this instruction and performance of sales ergotron com equipment in connection with this instruction Ergotron Inc reserves the right to make changes in the product design and or product documentation without notification to its users For the most current product information or to know if this document is available in languages other than those herein APAC Sales Worldwide OEM Sales please contact Ergotron No part of this publication may be reproduced stored in a retri
7. ctric Safety There are specific risks associated with the use of equipment having power cables You must be aware of and avoid these risks when this product is located in close proximity to children WARNING Failure to observe the following Electrical Safety notices can result in fire or death by electric shock Electrical cables can be hazardous Misuse can result in fire or death by electrical shock e Double Pole Neutral Fusing e Inspect power cables thoroughly before each use e Do not use cables that are damaged e Insert the plug completely into the outlet e Grasp the plug to remove from the outlet e Do not unplug by pulling on the cable e Do not use excessive force to make connections e Do not plug the cable into an extension cable e Do not remove bend or modify any metal prongs or pins of cable e Do not drive drag or place objects over the cable e Do not walk on the cable e Avoid overheating Uncoil the cable and do not cover it with any material e Do not run cable through doorways holes in ceilings walls or floors Keep this product away from water e Do not use when wet e Do not place this product in close proximity to flammable liquids or gases This product is intended for use only with loading as indicated Use with loads greater than indicated may result in instability causing possible injury The power cord acts as the connect disconnect device switching power on and off The socket outlet s
8. eval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise Tokyo Japan www ergotron com without the prior written consent of Ergotron Inc 1181 Trapp Road Eagan Minnesota 55121 USA www ergotron com info cem ergotron com Patents Pending and Patented U S amp Foreign Ergotron is a registered trademark of Ergotron Inc apaccustomerservice ergotron com 888 61 182 G 00 rev B 04 15 17 of 17
9. hall be installed near the equipment and shall be easily accessible CAUTION Changes or Modifications not expressly approved by Ergotron could void the user s authority to operate the equipment Use Safety There are specific risks associated with the use of this product for charging or storage You must be aware of and avoid these risks when this product is located in close proximity to children WARNING Failure to observe the following Use Safety notices may result in serious personal injury or equipment damage Only Adults should use this product e Do not allow anyone to climb or hang on this product e Do not block the fans and vent openings To prevent overheating leave at least 102 mm 4 inch clearance around fans and vents This product is designed to be used indoors only e Do not use this product to store equipment other than what has been noted in this guide e Do not use this product to store liquids or cleaning supplies e Do not place heavy objects on this product The maximum weight capacity is 44 4 Ibs 20 1 kg ERGOTRON This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation CAN ICES 3 A NMB 3 A ZORE TIZAREAEE CT CORE TR ERE CHAT DEERMEFSSEIFLIENHVT OS LC Dm rei H RETDIJERKS
10. ment and shall be easily accessible Power Indicator Communicates charge status with the following signals Light Description Off No power to the module On solid Tablets or Chromebooks are charging Specifications Dimensions 26 4 W x 35 6 H x 5 9 D 669 x 905 x 151 mm Weight w o equipment 64 5 Ibs 29 3 kg Rated weight capacity 44 41b 20 1 kg Maximum tablet or chromebook size Individual dimensions including cover up to 11 9 H x 8 9 W x 1 0 D 30 x 23 x 2 5 cm Individual tablet or chromebook weight up to 3 Ib 1 4 kg Cooling ventilation One 12V DC continuous operation fan Shipping dimensions 40 9 x 28 9 x 8 4 1040 x 735 x 214 mm Shipping weight 77 Ib 34 9 kg 888 61 182 G 00 rev B 04 15 Power system Part number Power System DM12 1006 1 Input 100 120V 12A 50 60 Hz DM12 1006 2 Input 220 240V 8A 50 60 Hz DM12 1006 3 Input 220 240V 8A 50 60 Hz DM12 1006 4 Input 220 240V 8A 50 60 Hz DM12 1006 5 Input 220 240V 8A 50 60 Hz DM12 1006 6 Input 100 120V 12A 50 60 Hz Environmental Temperature range Operating 0 to 30 C 32 to 86 F Storage 40 to 60 C 40 to 140 F Relative humidity maximum Operating 10 90 non condensing Storage 5 95 non condensing Altitude maximum 2000 m 6 562 ft Compatibility Tablets and chromebooks 15 of 17 Cleaning and Maintenance AN AN gt Me 5 A A Equipment Ele
11. t are not fully set in solid concrete will not support the applied load resulting in an unstable unsafe condition which could lead to personal injury and or property damage Consult a construction professional if you have well O Se CS your particular situation 80f 17 888 61 182 G 00 rev B 04 15 A Hang unit onto top bracket Warning 2 people are required to lift this product a Remove two screws on left side Save screws for reattaching cover 5 D Unlock door by turning key 180 clockwise Open door by turning knob 180 clockwise 6 a Open door and remove these 3 screws Save screws for reattaching cover b Remove left cover 888 61 182 G 00 rev B 04 15 a Secure unit to wall by inserting screw through back wall and into bottom right wall anchor D Close door then insert screw through back wall and into bottom left wall anchor WOOD STUD HOLLOW WALL CONCRETE 7 y gt EE ES 1 4 20 x 2 G T G JE SE 7 10 of 17 888 61 182 G 00 rev B 04 15 co R D J i PS a T Q U a Plug in all the tablet power cables into the outlets inside 8 Customer supplies power cables that come with the devices b Route cables through the access holes c Open door an pull cables through the access holes SO 7 aw