Home
User Manual
Contents
1. Fig 1 Tee 7 Lo O o B 120 A B 155 L e lt a 7 al i E Ey 5 D o E N i il o m Z Z _ tao Fig 2 Fig 3 Do not open any part of the luminaire without disconnecting line voltage The luminaire is to be used in Zone 1 Zone 2 or Safe Area WARNING The luminaire can only be installed in Zone 1 and Zone 2 if equipped with ATEX and IECEx approved cable glands and blind plugs Rubber seal and cables glands Be sure to install the cable in a way wich prevent water to penetrate into the enclosure through the cable gland also make sure to use the correct rubber seal when you install the luminaire Cable diam Size Part No 12 0 15 0mm 26 8 15 0x10mm 5002 0140 15 0 20 1mm 26 8 20 3x10mm 5002 0139 SPARE PART Part No 2943 3083 1223 1224 TEF 2430 FLASHLIGHT USER MANUAL Globe w guard red 1225 Globe w guard yellow 1226 Globe w guard blue 1227 Globe w guard yellow amber 2036 Gasket o ring for globe 107 5x3 53 nitrile 50008009 Cable gland Exe M25 Includes two rubber seals for cables 12 20mm 6222 502 Terminal block with brass plate 4128 Terminal block Wago 50280008 TECHNICAL DATA Material Cast copper alloy Globe polycarbonate Lexan Junction box in AISI 316L Supply Input voltage 110 VAC 50 60Hz 230 VAC 50 60Hz T rating T5 IP protection IP
2. TOOLS REQUIRED Regular tools required for installation e Tools for mounting e g 13 mm wrench to fasten the luminaire e 3mm hexagon key Unbrako for lock unlock safety pin on the guard ring e Flat head screwdrivers approx 3 5 mm for connect ing to terminal block and 8 0 mm for junction box lid earth screw e 32 mm wrench to disassemble the blind plug and assemble the cable gland e 25mm wrench for tightening the pressure nut on the cable gland MAINTENANCE INSTRUCTIONS The luminaire should be inspected according to Company routines The manufacturer suggests regular check for water intrusion condensation which should be removed immediately Check the drain plug drain hole function When cleaning use only mild detergents Alcohol or petroleum based products may damage lens paint or plastic components When cleaning the dome use moist cloth to avoiding electrostatic hazard Ex Approval Explosion category Ex II 2 G Ex de IIB GbT5 ATEX IECEx Ex de IIB T5 Canada Class Zone 1 AEx de IIB T5 US IECEx NEM 13 0016X Nemko 03ATEX064X CA 216432 Certificate No Approved for use in Zone 1 Zone 2 and Safe Area C 0470 JII 2 G Ex de IIB Gb T5 Ex de IIB T5 Class Zone 1 AEx de IIB T5 Marking Notified body Nemko AS Norway CSA International Canada INSTALLATION INSTRUCTIONS Only qualified personnel are allowed to perform installation and maintenance tasks to this equipme
3. 66 67 without drainplug IP54 with drainplug according to IEC 529 Power consumption Max 20 Watt Light source Xenon flash unit Tamb 30 C to 45 C Arctic version 55 C to 45 C Weight 6 kg Compliance with CENELEC EN 60079 0 2012 CENELEC EN 60079 1 2007 CENELEC EN 60079 7 2007 CSA Standard C22 2 No 0 M 91 General requirements Canadian Electrical Code Part II CSA Standard C22 2 No 0 4M 1982 Bonding and Grounding of Electrical Equipment Protective Grounding CAN CSA Standard C22 2 No 43 M 1984 Lampholder CAN CSA Standard C22 2 No 250 0 00 Luminaires CAN CSA E60079 0 02 Electrical Apparatus for explosive gas atmospheres Part 0 General Requirements CAN CAS E60079 1 02 Electrical Apparatus for explosive gas atmospheres Part 1 Flameproof Enclosures d CAN CAS E60079 7 02 Electrical Apparatus for explosive gas atmospheres Part 7 Increased safety e UL 1598 2000 First Edition UL Standard for Safety Luminaires UL 542 1999 Eight Edition UL Standard for Safety For Lampholders Starters and Starter Holders for Fluorescent Lamps UL 935 2001 Tenth Edition UL Standard for Safety For Fluorescent Lamp Ballasts ANSI UL 60079 0 2002 First Edition Electrical Apparatus for Explosive Gas Atmospheres Part 0 General Requirements ANSI UL 60079 1 2002 First Edition Electrical Apparatus for Explosive Gas Atmospheres Part 1 Flameproof Enclosures d ANSI UL 60079 7 2002 First Edition Electrical Appa
4. TUM 2402 REV C 14 10 2014 TEF 2430X IECEx Ex de XENON FLASHLIGHT USER MANUAL IMPORTANT Read this instruction carefully before installing the product a 226 pe Sa lt O a TRANBERG Tranberg AS P O Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com TEF 2430X FLASHLIGHT USER MANUAL INTRODUCTION APPROVAL Thank you for purchasing this product For installation maintenance and assurance of a long life of this product please follow this manual APPLICATIONS e Flash light e Signal lighting e Obstacle marking e Zone 1 zone 2 and safe area CONTENT IN BOX The product is fully assembled and ready for installation SAFETY PRECAUTIONS Note that changes made to the product and or installation of components which do not conform to the approval may be a safety violation The manufacturer will in no circumstance be held responsible for such activity For your health and safety always use safety gear suited for the task Be certain to follow codes regulations and or specific procedures that are related to the installation
5. ectrical wires or the safety wire to the lid itself are jammed between the lid and the junction box Not following these instructions may lead to a risk of water ingress into the luminaire The manufacturer assumes not responsibility when these guidelines are not followed TEF 2430X FLASHLIGHT USER MANUAL The terminal block of this luminaire is of the cage clamp type and one needs either special tool or just a small flat head screwdriver to connect the cable to terminal block The cable glands are approved for a specific cable diam eter These data can be found in the certificate of the ATEX approved cable glands Make sure this is not violated Use of cable with other dimensions is a safety violation and should be avoided Any damage caused by use of incorrect cable gland not matching the cable dimension is not the responsibility of Tranberg AS and is not covered by warranty Max cross section of the cable to be connected to the terminal blocks is 2 5 mm To connect the wiring of the TEF 2430 luminaire perform the following procedure Remove the cover from the connection box Connecting cable for 230 VAC 50 60 Hz or 110 VAC 50 60Hz The main power is to be connected to the terminal blocks marked 11 and 22 see fig 2 Make sure electrical connections are safe and reliable Make sure the wire slack is as needed Reinstall the cover If properly mounted and installed the luminaire is now ready for use Replacem
6. ent of flasher unit Deactivate the input power Remove the unlock safety pin marked as 1 in fig 3 Remove the ring with globe and guard marked 2 in fig 3 and remove and replace the flasher unit If necessary lubricate the threads with grease Renolit Unitemp 2 from Fuchs Reinstall the ring with globe and guard and fasten the safety pin Troubleshooting No light Check main power connections to the terminals blocks or flasher unit connections If the light still does not function contact the nearest Tranberg dealer or Tranberg AS directly Safety precautions Note that changes made to this product and or installation of components which do not conform to the approval may be a safety violation The manufacturer will under no circumstances be held responsible for personal injuries death or any damage caused by such activity For your health and safety always use safety gear suited for the task and follow company guidelines and all relevant rules and norms for installation where applicable Description Flashing insert 230 VAC 50 60Hz Flashing insert 110 VAC 50 60Hz Globe w guard clear Globe w guard green
7. nt The equipment is ready for installation when leaving the production facilities of Tranberg AS Check the condition of the equipment and the contents when unpacking Any damage done to the equipment during the transportation is not the responsibility of Tranberg AS If the content is not complete file a claim to the producer immediately The TEF 2430 is mounted on a bracket which have several mounting choices using 2 pcs of M8 max bolts and nuts or 2 pipe The dimensions of the mounting bracket are shown in fig 1 Important when mounting the luminaire The luminaire must always be installed in such a way that the junction box is fully supported from underneath Normally the entire luminaire would be installed to a flat sur face which provides a proper support for the junction box In cases where the junction box cannot be mounted on the same surface as the lamp housing bracket a full and rigid support must be provided for the junction box An unsupported junction box may be damaged if stepped upon Likewise an unsupported junction box that is forced down by e g a pull of electrical cables may expose the gasket between the junction box and lamp housing Do not use excessive force when tightening the four screws on the junction box lid and never use a power screwdriver Excessive force may bend the lid and provide a way for water to enter the junction box When closing the lid on the junction box please ensure that no el
8. ratus for Explosive Gas Atmospheres Part 7 Flameproof Enclosures e TRANBERG Tranberg AS PO Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com
Download Pdf Manuals
Related Search
Related Contents
Manual de instalación Monte Carlo Fan Company 5GIR54XXD User's Manual JBL CS-4 car speaker D-Link DWL-G810 User's Manual SCN71800F0 DEBenutzerinformation 2 TR Kullanma Kılavuzu 20 Triarch 31135 User's Manual Valueline VLTP90995W telephone splitter Integral Assessment Module for Coastal Zone Management Copyright © All rights reserved.