dsp 3-10kva mono user manual

image

Contents

1. Physical Specifications Height 68 cm Width 27 cm Depth 67 cm Weight 49 kg Environnemental Conditions Temperature PREME 0 40 PC Relative Humidity Cree eae Storage 15 55 PC Storage 9 920 9 995 Electrical Specifications System Efficiency with Input voltage 220 V and full capacity batteries 0 9100 linear 50 linear 7 9100 non linear 50 nonlinear Load Load Load cos 0 7 Load cos 0 7 Normal Operating online mode gt 91 7 gt 90 9 gt 90 1 289 8 Green Mode by pass mode 296 7 294 5 296 3 295 0 Cross Sections of Connection Cables Ground Connection 10 mm Input phase amp neutral 10 mm By pass connection 6 mm Output phase amp neutral 6 mm Battery 6 mm Input Phase Number 1 Nominal Voltage 220 V Nominal Frequency 50 Hz Input voltage range at mains running 9450 Load 80 280 V Full load 157 280 V Input frequency tolerance 45Hz 65Hz Input current Limit 38 A Fuse current and type 32A C Type Power factor at nominal input voltage Full load gt 0 990 Half load gt 0 971 Current Total Harmonic Distortion THD 100 linear Load at nominal input voltage lt 4 6 Output online amp battery Operation Phase number 1 Voltage wave form Sinusoidal Nominal Power kVA 6000 VA Nominal active power 4200 W Nominal voltage 220 V Nominal current 27A Frequency mains present
2. Nominal battery Battery capacity App Weight Battery Quantity Total nominal Total battery voltage per bat per battery per battery battery voltage weight 12V 7 Ah 2 4 kg 20 240 V 48 kg 12V 12Ah 4 1 kg 20 240 V 82 kg Approximate bridging times Full load 20 pcs 7 Ah battery 9 min Half Load 20 pcs 7 Ah battery 24 min Full load 20 pcs 12 Ah battery 20 min Half Load 20 pcs 12 Ah battery 52 min Battery Recharge Time 80 capacity for 7Ah App 4 Hours Battery Recharge Time 80 capacity for 12Ah App 7 Hours Temperature controlled battery charging General Specifications Audible Noise 1m away from the front of the unit lt 50 dB Isolated Free Contact communication and serial communication RS232 according to EN60950 At Normal Operation online amp battery operation electronic short circuit protection At Normal Operation online amp battery operation overload capability At Normal Opetation online amp battery operation capability of holding inrush currents Over temperature Overvoltage Over current and battery deep discharge protections Fan speed control present LCD Display Standards Protection Class IP 20 EMC EN 50091 2 Performance EN 62040 3 EN 50091 3 Safety EN 50091 1 288713578 34 11 Technical Specifications 6kva Saver DSP
3. 10 i 0 1 amp 0 01 amp 0 001 0 10 20 30 40 50 60 70 80 Temperature C To check the autonomy time for certain load level you choose normal operating mode please turn the input fuse to 0 position while the UPS is loaded with the desired load level Then UPS passes to battery mode You will see on the screen BUV sign UPS will shutdown in a few minutes The time between by pass mode and switch off of the UPS is the autonomy time If you don t want any interruption on the load please turn the input fuse to T position when you see the BUV message Please make sure that the batteries are full before the test 288713578 18 5 1 3 4 Temperature Management UPS measures the temperature of some points inside the UPS and calculates the temperature of semiconductor junctions by using electrical values temperature of which is immeasurable In this way Overload time is precisely calculated UPS is able to perform advanced over temperature protection 5 1 3 5 Communication Interface Please contact to authorize distributor to be informed how to get SNMP adapter software communication cable modem etc Communication interface has the following features Communication without operator Direct communication between your PC and UPS Add as a new Client to the Network Inform the operating mode to an external unit Above features are optional AN Do not remove or plug in communication interface d
4. T just for the actual situation If any other problem occurs later on different than the previous reason than the buzzer shall be heard with an audible sound in order to warn the user about the new situation 288713578 25 6 Important Operating Notices Uninterruptible Power Supplies UPS have an important function in the protection of the critical and sensitive loads from the bad mains electricity conditions and they are used to supply uninterruptible energy to these loads In such bad mains electricity conditions the user can provide an artificial energy supply to the equipments present in the office or at home by using an UPS The electricity network system in a building should be established professionally according to the suitable conductor quality cross section selection necessary earthing and distribution principles An user who is willing to create an artificial energy supply in an office or at home environment by using an UPS should be careful about some points during the installation of the connections between the equipments that are going to be fed by UPS Otherwise normal operation of UPS without a failure or user s safety cannot be secured Person health and related items regarding this issue are listed under the section Security Warnings of the user manual In this section these points shall be notified again and necessary information concerning the connections between UPS and the supplied equipments shall be provide
5. is a very simple example for this situation and it is shown in the below diagram Computer takes its earthing PE via the distribution panel where the UPS is connected Because of the security precaution explained above computer s communication connectors are also at this protecting earthing level The printer s communication connectots which are connected to a socket that is not fed by the UPS takes the protecting earthing level via this socket The important point during the connection of computer and the printer to each other is to keep the potential difference small between the distribution panels and socket s earthing At well earthed building installations this difference is zero Otherwise from both sockets a balancing current shall flow continuously in order to equalize the earthing levels when the intermission connection cable is connected This current shall cause an interruption on the communication or a failure on the communication ports As far as possible all the tigging s power connections that are connected to computer system should be made to a single socket via UPS 288713578 26 BATTERY CABINET Communication interface Grounded socket DISTRIBUTION At some building electricity distribution systems there can be sockets just composed of two lines phase amp neutral but may seem like a socket with earthing This socket s earthing point is either not connected to the protecting earthing or it is
6. SAVER DSP SERIES SINGLE PHASE IN SINGLE PHASE OUT 3 10kVA USER MANUAL inform UNINTERRUPTIBLE POWER SUPPLY UPS 288713578 Important Notices Thank you for choosing Inform UPS Systems This document provides all the instructions necessaty for the installation and the operation of the Saver DSP Uninterruptible Power Supply For the staff and the equipment safety it is necessary for the users to fully read and understand this manual before working on this equipment CS Please read the manual carefully before working on this equipment E Please keep the manual Description of the Symbols Se IMPORTANT NOTICE Please follow the instructions AN LIFE RISK Please follow the instructions AN DANGER Please follow the instructions otherwise the unit can be damaged or user can be hurt 288713578 No m o N A EA C M QN 1 System Description X deosdenesstesadesdvsseacscegssdeaductanssasassdessednasesassssdsvenadecesadssadsneacsensssbetes 2 Installation T M 5 34 Hando seas peer aq pu seas a va annie ave ev ERR M EI NE 5 32 Storage E 5 3 3 Positioning JA T COMME COTS Sera E a GEE E EA E renee ty events AA A A E E R RAEE 6 3 4 1 Ground Earth Connection tentent nentntentenententente tentent entente tente entente tannini 7 3 4 2 Input Connection ee ueniet e ead dais eee eet h
7. Isolated Free Contact communication and serial communication RS232 according to EN60950 At Normal Operation online amp battery operation electronic short circuit protection At Normal Operation online amp battery operation overload capability At Normal Operation online amp battery operation capability of holding inrush currents Over temperature Overvoltage Over current and battery deep discharge protections Fan speed control existence varies according to model type LCD Display Standards Protection Class IP 20 EMC EN 50091 2 Performance EN 62040 3 EN 50091 3 Safety EN 50091 1 288713578 38 13 Technical Specifications 10kva Saver DSP Physical Specifications Height 78 cm Width 27 cm Depth 73 cm Weight 55 kg Environnemental Conditions Temperature PREME 0 40 PC Relative Humidity Cree ea Storage 15 55 PC Storage 9 920 9 995 Electrical Specifications System Efficiency with Input voltage 220 V and full capacity batteries 9 5100 linear 9 550 lineat 9 100 non linear 50 nonlinear Load Load Load cos 0 7 Load cos 0 7 Normal Operating online mode 29241 291 2 291 9 291 2 Green Mode by pass mode 297 295 5 2
8. Therefore UPS stops operating in battery mode when the battery capacity falls below 30 of its total capacity 5 1 1 4 Shutdown SHUTD During the shutdown mode even the UPS is switched on there is no energy on the output and load is not supplied UPS makes self test during the start up to check if everything is normal During this operation UPS is on shutdown mode Other shutdown mode conditions User push the 0 button when the by pass input is out of the limits UPS switches into shutdown mode if by pass input voltage gets beyond limits while mains voltage is within limits and UPS is disabled Sending shut down command through communicate interface when the operating type is ups out of function is selected Switching on the manual bypass switch to I position when the bypass input supply is not within allowed limits 288713578 13 In addition During the battery mode if shut down command is sent through the communication interface and if the mains comes back to normal conditions for a short period UPS passes to shutdown mode and then passes to normal mode chosen by the uset on line green or by pass mode operating mode During the on line or green mode operation if shut down command is sent through communication interface for a short period UPS passes to shutdown mode and then passes to normal mode chosen by the user on line green or by pass mode operating mode If 0 button is pushed
9. operation When the by pass input turns to its normal conditions it passes to by pass mode If the by pass and mains input are not available or out of limits UPS passes to battery mode Which ever comes to its normal conditions first UPS passes that operation mode On green mode inverter is off and efficiency is very high This provide energy saving CH Itis suggested to use normal operation During the green mode load is not fully protected against output short circuits and disturbances You will see on the right top of the screen as G sign indication during the green mode operation g P 8 g g To pass to on line mode operation from the green mode operation please push the T button Two times if there is an audible alarm 288713578 15 One time if there is no audible alarm To pass to UPS out of function operation please push the O button 5 1 2 3 UPS out of Function Shutting down the UPS has two steps First you shall push 0 button and you will see 0 sign at the right top of the screen UPS 1s out of function If the by pass input is within the limits UPS operates on by pass mode If the by pass input is out of the operating tolerance UPS passes to shutdown mode when the mains input is in online operating limits UPS switch off when the mains input is out of the operating limits Then by turning to 0 positions all fuses on the rear side of the UPS you can switch off the unit complet
10. 288713578 II 10 11 12 13 Technical Specifications 5kva Saver DSP esses eene 33 Technical Specifications 6kva Saver DSP c ccssscessscessscesseeesseeceseesessesessescsseeesseeceseesessesesseeesseees 35 Technical Specifications 7 5kva Saver DSP sss eene entente nennen 37 Technical Specifications 10kva Saver DSP esses eene enne nennen nnne nennen 39 288713578 III 1 Safety AN For the staff and equipment safety it is necessary for the users to fully read and AN understand this manual before working on this equipment Avoid the sudden temperature changes which can cause condensation inside the UPS Otherwise wait for at least two hours before switching on UPS has to operate in an environment suggested in this manual Please read chapter 3 3 Positioning Do not close ventilation holes or other openings Do not let enter any foreign materials inside the UPS Installation and commissioning have to be done by authorized technical service Earth ground connection has to be done Do not plug in and remove the communication interface cables during the lightning weather conditions Avoid the risk of fire all the connections have to be done by suggested cable dimensions All cables have to be isolated and propetly installed Do not connect overload to the UPS output Do not open the UPS doors There is high voltage risk Maintenance has to be done by authorized t
11. 75 non linear cos P 0 7 load lt 3 2 7 0100 linear Load lt 2 5 7 0100 nonlinear cos 0 7 load lt 4 1 Overload holding time 0 to 150 load variation 35s NOTE Overload holding time is a software parameter and can be changed upon request Fault removal current For B type fuse 13 6 A For C type fuse 6 8 A By pass Line 288713578 37 Phase number 1 Nominal frequency 50 Hz Nominal power kV A 7500 VA Nominal active power 5250 W Nominal voltage 220 V Nominal current 34A Fuse value used in the panel 40Amp C type Bypass input voltage range 198V 242V Bypass input frequency range 47Hz 53Hz NOTE By pass voltage and frequency are software parameters and can be changed upon request Transfer Time 0 ms Batteries Battery type Sealed Maintenance free lead acid The quantity and capacity of batteries located inside the ups cabinet Nominal battery Battery capacity App Weight Battery Quantity Total nominal Total battery voltage per bat per battery per battery d battery voltage weight 12V 12 Ah 4 1 kg 20 240 V 82 kg Apptoximate bridging times Full load 20 pcs 12 Ah battery 10 min Half Load 20 pcs 12 Ah battery 30 min Battery Recharge Time 80 capacity App 7 Hours Temperature controlled battery charging General Specifications Audible Noise 1m away from the front of the unit 55 dB
12. LCD panel and wait When the bypass input regains the conditions that are allowed then BYPASS OK G message will appear on the front panel When you observe this message you can use the manual bypass switch and bring it to I position The uninterruptible transfer shall be obtained with this way Transfer from Manual bypass to Normal ONLINE Operation Mode e If the ups is switched off then bring the battery output bypass and input fuses to 1 position respectively e Be sure that ups is switched on e After a while please be sure that you observe MB message on the front LCD panel and the bypass LED is litting e Bring the manual bypass switch to 0 position e Wait at least 10 seconds e Observe ONLINE OK message on the front panel if there is mains or BATTR OK message if there is no mains e If you receive BATTR OK message on the front panel please be sure that you have mains connection and the ups input fuse and the distribution box input fuse is at 1 position 5 1 3 Operating Features and Values 5 1 3 1 Online Mode and Voltage Tolerance Voltage tolerance sub limit for on line operation depends on the load level Load and voltage relation is given for the sub limit in the chapter 9 Voltage tolerance for upper limit does not depend on the load and is 280V If the voltage is over 280V UPS passes to battery mode To come back to on line mode it is necessary that the voltage sho
13. Locked to the input Frequency normal run 50 Hz 0 005 Power factor 0 7 Crest Factor at nominal power 3 1 Static voltage regulation 0 100 load variation 91 Voltage Total Harmonic Distortion THD 76 0 Load 0 8 25 linear Load lt 1 7 25 non linear cos 0 7 load 2 2 50 linear Load lt 1 7 50 non linear cos P 0 7 load lt 2 3 75 linear Load lt 2 1 75 non linear cos 0 7 load lt 2 8 100 linear Load 2 100 nonlinear cos 0 7 load 3 6 Overload holding time 0 to 7 0150 load variation 61 s NOTE Overload holding time is a software parameter and can be changed upon request Fault removal current For B type fuse 13A For C type fuse 65 A 288713578 35 By pass Line Phase number 1 Nominal frequency 50 Hz Nominal power kV A 6000 VA Nominal active power 4200 W Nominal voltage 220 V Nominal current 27A Fuse value used in the panel 32Amp C type Bypass input voltage range 198V 242V Bypass input frequency range 47Hz 53Hz NOTE By pass voltage and frequency are software parameters and can be changed upon request Transfer Time 0 ms Batteries Battery type Sealed Maintenance free lead acid The quantity and capacity of batteries located inside the ups cabinet p e e E C ww cee ee 12V 7 Ah 2 4 kg 20 240 V 48
14. acceptable limits if one of the below conditions occur UPS passes to by pass mode If normal conditions are obtained then UPS passes to on line mode Prolonged overloading Over temperature Failure on the UPS The ups stays at bypass mode at least 10 sec before switching back to online operation mode 288713578 12 During the on line operation if the by pass input voltage is within acceptable limits or in green mode operation when you push to 0 button UPS passes to by pass mode If the by pass input voltage is out of limits UPS does not pass to battery mode and switch off itself If the UPS is transferred to by pass mode by pushing 0 button in case by pass input voltage is CE out of the limits UPS passes to shutdown mode or switch off depending on mains voltage It is suggested to use green mode if you don t want any interruption If the by pass input voltage gets out of limits after the 0 button is pressed during on line operation UPS shall switch into Shutdown Mode If UPS passes to by pass mode because of overload conditions and by pass input voltage gets out of the limits it is dependent on the amount of load for the ups to return to online operation 5 1 1 3 Battety Mode BATTR In this mode of operation UPS converts the battery voltage to a suitable DC voltage which can be converted to a voltage value equal to mains voltage of the inverter UPS is at the same time on by pass mode This is an exce
15. kg 12V 12Ah 4 1 kg 20 240 V 82 kg Apptoximate bridging times Full load 20 pcs 7 Ah battery 6 min Half Load 20 pcs 7 Ah battery 19 min Full load 20 pcs 12 Ah battery 15 min Half Load 20 pcs 12 Ah battery 40 min Battery Recharge Time 80 capacity for 7Ah App 4 Hours Battery Recharge Time 80 capacity for 12Ah App 7 Hours Temperature controlled battery charging General Specifications Audible Noise 1m away from the front of the unit lt 50 dB Isolated Free Contact communication and serial communication RS232 according to EN60950 At Normal Operation online amp battery operation electronic short circuit protection At Normal Operation online amp battery operation overload capability At Normal Operation online amp battery operation capability of holding inrush currents Over temperature Overvoltage Over current and battery deep discharge protections Fan speed control present LCD Display Standards Protection Class IP 20 EMC EN 50091 2 Performance EN 62040 3 EN 50091 3 Safety EN 50091 1 288713578 36 12 Technical Specifications 7 5kva Saver DSP Physical Specifications Height 68 cm Width 27 cm Depth 67 cm Weight 50 9 kg Environnemental Conditions Temperature PREME 0 40 PC Relative Humidity Cree e
16. line mode is chosen the mains input is in the acceptable limits and there are no abnormal conditions such as over temperature overload failure etc Green mode is chosen by pass input voltage is out of limits but the mains input voltage is in the acceptable limits and there are no abnormal conditions such as over temperature overload failure etc UPS operates in on line mode 5 1 1 2 By pass Mode BYPASS If the voltage in the by pass input is transferred to the output by using either electronic or manual switch this mode is called by pass mode Your UPS has both electronic static and manual switch You can pass to Maintenance Bypass Mode by using the manual bypass switch on the ups This switch is used to transfer the bypass voltage to the output of the ups manually when the ups is aimed to be disfunctioned to be used the connected loads can be transferred to the bypass line without interruption by f Maintenance Bypass Switch manual bypass switch is an uninterruptible switch In case of need following the instructions in chapter 5 1 2 4 On by pass mode by pass input voltage is transferred to output through the thyristors Load is supplied by by pass input voltage Inverter is off By pass input voltage must be within the operating limits The unit Stays at this mode when green mode is chosen if by pass input voltage is within the acceptable limits On line mode is chosen by pass input voltage is within the
17. of the Display the name of the variable that is selected by mode button can be displayed The mentioned variables are important measurements related with the operation of the ups which concerns the user The following variables can be observed LOAD It indicates the load as the load s current drawing power versus UPS s nominal power LOAD output active power output nominal power 100 TBAT It indicates the time in minutes that the ups can work from the batteries VIN It indicates the effective value of the input voltage as Volt V VBAT It indicates the average battery voltage as Volt V at 3 5 6 and 7 5kKVA but it indicates the half of the average battery voltage as Volt V at 10kVA ups VOUT It indicates the effective value of the output voltage as Volt V FOUT It indicates the output frequency as Hertz Hz On the Variable section one variable at a time can be displayed 288713578 23 5 2 1 2 LEDs On the Panel there are six LED indicators present The definitions of these LEDs are explained below Line This green LED lits when the equipment s input voltage value is within the online operating limits If the mains voltage goes out of on line operation limits than this green light starts blinking Battery This red LED lits if the unit is working from batteries and the remaining battery capacity is greater than 30 lits during the start up test Blinks during battery operation and when the remaining batt
18. of the UPS and batteries are between 0 40 C It is suggested to provide an environment temperature between 20 25 C to get maximum performance from the UPS and batteries Environmental humidity must be between 20 80 none condensing 3 4 Connections Connections must be done by authorized technical service staff Life risk for user Temperature changes such as from cold to hot environment may cause condensation It is AN dangerous to operate the UPS Please wait at least two hours before making the connections Connection terminals are in the rear side of the UPS Please take out the cover of the rear side to make the connections Standard UPS fuses and connectors settlements are shown below BATTERY FUSE M Me SE output FUSE MANUAL BYPASS FUSE OUTPUT GROUND CLEMENS PE OUTPUT PHASE CLEMENS L2 OUTPUT HEUTRAL CLEMENS H2 BATTERY PLUS CLEMENS B BATTERY 0 POINT CLEMENS H3 BATTERY MIHUS CLEMENS B INPUT NEUTRAL CLEMENS H1 BATTERY GROUND CLEMENS PE PUT PHASE CLEMENS L1 INPUT GROUND CLEMENS PE 288713578 6 Units with internal batteries have hazardous voltages on the battery connectors even if the battery circuit breaker is in 0 position Do not touch the battery connectors Units with internal batteries can produce output voltage even 1f no connection is made Therefore it is mandatory to keep all circuit breakers in 0 position and not to push the buttons on
19. passes to by pass Our UPS behaves like a current source In case of high inrush current consumption UPS adjust the output voltage and fix the current value Load is not affected from inrush current On line and battery modes operations in short circuit conditions In case of a short circuit at output UPS behaves like current source In case of high current consumption UPS adjust the output voltage and fix the current value and trigger the fuse between UPS and load So short citcuit condition is over and other loads are not affected Normal UPSs switch off in such cases Thanks to algorithms used in the battery charge amp discharge battery lifetime is extended This helps gt To continue charging the battery even the mains input go down to 130V gt Load independent charging voltage Info mont Battery Management gt Current ripple is minimum level during the discharge Additionally gt Battery autonomy time is calculated thanks to artificial intelligent algorithms gt Battery testing is available gt UPS measures the temperature of different internal parts and calculates semi conductor junctions temperature This helps Temperature Management gt To calculate overloading time in a reliable way gt To protect against over temperature Overload Time Management UPS continues its online operation for a certain period during overload condition This depends on overload percentage and temperatu
20. the MB indication is observed at this location On the alarm section of the Display abnormal situation of the current is indicated with an alarm signal The following messages can be observed in this section OK It is observed when there is no alarm FANEL It is observed when at least one of the fans fails DCFL It is observed when the DC voltage at the input of the inverter is not normal BOVTE It indicates that the measured temperature environmental temperature in the air entrance of the equipment is too high This measured temperature can be accepted as equal to battery temperature if there is no problem with the battery charging and if the batteries are located in an additional cabinet which has the same environmental conditions as the ups cabinet BUV It is observed when the battery remaining capacity decreases to 30 of the total battery capacity BATTF It indicates that the battery test has been failed BFUFL It indicates that the battery fuse has been switched off for some reason or this fuse has been turned to 0 position OVTE It indicates that the equipment s cooler s or semi conductor s junction temperature is too high OVLD It indicates that the actual connected load capacity is more than the UPS nominal power In case that more than one alarm happens at the same time than the code of the below alarm message is observed among the alarm messages listed above respectively On the Variable section
21. the right side of the display If OUTFLR conditions are finished if you push twice to T button UPS starts to its normal operation Before to start the normal operation please check the fans on the rear side If the fans are not CS working please contact to technical service AN Do not open the case or put any object in the holes to check if the fans are working 288713578 14 5 1 1 7 Wait Mains WIMNS Wait mains means that UPS cuts off the output voltage until the mains input comes to allowed limits When the mains input reaches to acceptable limits UPS passes to on line mode In order to start WIMNS operation you need to send the shutdown command through communication interface during the battery mode At the end of time given by the user UPS pass to WI MNS operation If shutdown command is sent during the on line ot green mode at the end of defined time UPS passes to shutdown mode and then returns to the operation mode defined by the selected operating type During the WI MNS operation if you want to switch on the UPS manually Please press first to 0 button and switch off and push to CS button UPS starts on battery mode 5 1 2 Operating Types 5 1 2 1 Online Priority Operating Normal Operation When you turn the input fuse to I position if the mains voltage is over 130V UPS is switched on and after the test if everything is normal and if the 0 and T buttons were not pressed during the
22. 9 0 295 6 Cross Sections of Connection Cables Ground Connection 10 mm Input phase amp neutral 10 mm By pass connection 10 mm Output phase amp neutral 10 mm Battery 10 mm Input Phase Number 1 Nominal Voltage 220 V Nominal Frequency 50 Hz Input voltage range at mains running 9438 Load 80 280 V Full load 150 280 V Input current Limit 63A Fuse current and type 63A C Type Power factor at nominal input voltage Full load gt 0 99 Half load gt 0 99 Current Total Harmonic Distortion THD 100 linear Load at nominal input voltage lt 6 0 Output online amp battery Operation Phase number 1 Voltage wave form Sinusoidal Nominal Power kVA 10000 VA Nominal active power 7000 W Nominal voltage 220 V Nominal current 455 A Frequency mains present Locked to the input Frequency normal run 50 Hz 0 005 Power factor 0 7 Crest Factor at nominal power 3 1 Static voltage regulation 0 100 load variation 01 Voltage Total Harmonic Distortion THD 76 9 00 Load 0 9 25 linear Load lt 1 3 25 non linear cos P 0 7 load 1 8 50 linear Load lt 2 1 50 non linear cos P 0 7 load 30 75 linear Load 2 5 75 non linear cos 0 7 load lt 4 1 100 linear Load lt 2 5 7 0100 nonlinear cos P 0 7 load lt 7 3 Overload holding time 0 to 150 load variation 49 s NOTE Overload holding time is a software parameter and can be changed upon request Fault removal current For B type fuse lt 15A For C type fuse lt 7 5
23. A 288713578 39 By pass Line Phase number 1 Nominal frequency 50 Hz Nominal power kV A 10000 VA Nominal active power 7000 W Nominal voltage 220 V Nominal current 455A Fuse value used in the panel 50Amp C type Bypass input voltage range 198V 242V Bypass input frequency range 47Hz 53Hz NOTE By pass voltage and frequency are software parameters and can be changed upon request Transfer Time 0 ms Batteries Battery type Sealed Maintenance free lead acid The quantity and capacity of batteries located inside the ups cabinet Nominal battery Battery capacity App Weight Battery Quantity Total nominal Total battery voltage per bat per battery per battery i battery voltage weight 12V 12 Ah 4 1 kg 20 240 V 82 kg Approximate bridging times Full load 20 pcs 12 Ah battery 8 min Half Load 20 pcs 12 Ah battery 25 min Battery Recharge Time 80 capacity App 10 Hours Temperature controlled battery charging General Specifications Audible Noise 1m away from the front of the unit 55 dB Isolated Free Contact communication and serial communication RS232 according to EN60950 At Normal Operation online amp battery operation electronic short circuit protection At Normal Operation online amp battery operation overload capability At Normal Operation online amp ba
24. ackout the loads CH shall remain without enetgy position and the ups is at switched off position when the manual bypass switch is at 1 position Do not work on these locations before switching the manual bypass switch to 0 position There is still energy on the UPS s output Clemens and the loads although all the fuses are at 0 288713578 16 The possible situations that can occur during the use of manual bypass switch are listed below if you can not transfer the ups to static bypass by pressing the I button receiving the ONLINE OK G message on the front panel then e Be sure that the bypass connection of the ups has been done properly and the bypass fuse of the ups is at I position e If you still can not get BYPASS OK G message than the bypass voltage and or frequency values ate not available for bypass transfer If you bring the manual bypass switch to P position then you will supply an inconvenient voltage and frequency to your connected loads During this transfer even your loads can remain without energy for a small period of time if you receive BATTR OK message on the front panel although the bypass and input fuses of the ups is at T position then e the ups is operating from the batteries due to the absence of the input mains In this condition please press the T button enough in order to pass to GREEN MODE operation observe the G letter on the bottom line of the
25. ae Storage 15 55 PC Storage 9 920 95 Electrical Specifications System Efficiency with Input voltage 220 V and full capacity batteries 9 5100 linear 9 550 linear 9 100 non linear 9 550 nonlinear Load Load Load cos 0 7 Load cos 0 7 Normal Operating online mode 291 5 290 9 290 1 289 7 Green Mode by pass mode 296 7 295 0 296 1 294 8 Cross Sections of Connection Cables Ground Connection 10 mm Input phase amp neutral 10 mm By pass connection 10 mm Output phase amp neutral 10 mm Battery 10 mm Input Phase Number 1 Nominal Voltage 220 V Nominal Frequency 50 Hz Input voltage range at mains running lt 50 Load 80 280 V Full load 156 280 V Input current Limit 45 A Power factor at nominal input voltage Full load gt 0 992 Half load gt 0 982 Current Total Harmonic Distortion THD 100 linear Load at nominal input voltage 5 5 Output online amp battery Operation Phase number 1 Voltage wave form Sinusoidal Nominal Power kVA 7500 VA Nominal active power 5250 W Nominal voltage 220 V Nominal current 34A Frequency mains present Locked to the input Frequency normal run 50 Hz 0 005 Power factor 0 7 Crest Factor at nominal power 3 1 Static voltage regulation 0 100 load variation 01 Voltage Total Harmonic Distortion THD 76 0 Load 0 9 25 linear Load 1 5 25 non linear cos P 0 7 load 20 50 linear Load 1 8 50 non linear cos P 0 7 load 2 6 7 75 linear Load 2 5
26. as battery testing feature It warns the user for battery life Battery test is done in every 90 days automatically If user has software user may perform battery test whenever required The best result is taken when the batteries are full and UPS is operating on nominal load During the battery test UPS passes to battery mode and it takes maximum 10 seconds During this test if the battery voltage goes below a certain level battery test fails You may see BATTF sign on the screen and UPS gives audible alarm and fault led blinks At the end of test UPS goes to its previous operating mode but the alarms continue If the Line led is always on even the mains input is available BATTR sign exists on the display and battery led is on it means battery test is on process If the test is done when the batteries are empty please let the UPS charge the batteries first Please check BATTEFE sign disappears If not contact to authorized service ce If battery test fails one of the possible reasons is that batteries are at the end of their lifetime Please contact to authorized service If the performed test is successful UPS continues to its previous operation mode Battery lifetime depends on the battery type charge discharge quantity discharge depth and environmental temperature Please see below figure battery life is the zone between the two lines Temperature Battery lifetime i 100 pue
27. c fuse which connects the output of the ups to the by pass input It is used for mainly maintenance purposes on the ups without disenergizing the load from the mains supply By pass Input In some cases it is requested to supply by pass line from another mains or sources In this application it is used split by pass Please inform your contact about your need IGBT Technology Compact design small dimensions and low weight Transformerless design DSP is 200 times faster than standard microprocessors This provides DSP digital signal processor gt To use all the sources in optimum level technology gt To observe carefully the failure conditions High input power factor This helps gt To consume low reactive power PFC technology gt Not to load the installation extra cables transformers generators gt Clean power for the mains Wide input voltage tolerance on line operation even the mains is between 80 280 V This helps to reduce battery usage and guarantees battery to be fully charged and extends the battery life time On line double conversion technology UPS output voltage is sine wave same as ideal mains source UPS output total harmonic distortion is very low On line and battery modes Some loads when they are switched on consumes high inrush current 288713578 Feature Benefit operation against inrush current On such cases normal UPS switches off or
28. connected to neutral point instead When there is no flow of current on the neutral line than it may be on a protecting earthing level When these sockets and other parallel sockets are loaded the neutral voltage shall be different than the protecting earthing level which causes a security problem concerning the connected riggings and the person health AN The authorised staff should control the supporting riggins of the equipments that are connected to the UPS if they have been connected to the earthed sockets The UPS that is supplying the computers and their supporting riggings should have been connected to the distribution panel directly The equipments having high noise and leakage current such as refrigerator or climate should not be connected to the same fuse with the UPS Otherwise there can be some problems regarding noise and leakage current protection 288713578 27 7 Maintenance The unit does not need maintenance but the batteries may need maintenance depending on their type or they needed to be replaced after their lifetime is over The lifetime of the batteries is approximately 3 10 years if they are used in an environment having 10 20 C temperature value More information about the lifetime of batteries can be obtained from battery management and bridging time section If you want to make cleaning on the unit than you should perform the following Disconnect the loads Bring all the fuses on the unit to 0 posit
29. d The connection of the UPS to the mains should be done with the right cross sectional cables according to the explanations given in the Installation section and this should be performed by authorized staff UPS should be connected to a well earthed panel which can provide the necessary amount of current written on the label at the rear part of the ups Computer and supporting riggings are the main equipments protected by UPS Such equipments power connections ate composed of two pcs power entries and one pc Earthing PE lines Earthing PE line is connected to the contacting metal surfaces of the unit in order to protect the user from the leakage current or electrical shock in case of failure situation Computers and its riggings communication connectors are also the contactable metal surfaces Therefore each pin of these connectors should be suitable according to the earthing PE potential or at a very small potential which may not harm a person Equipment which is supplied from a non earthed or not well earthed panel socket constitutes an electrical shock danger to the user At the same time possibility of a failure on the electrical circuits is too high On the computer and supporting riggings other than the power connections another connection is needed where the earthing PE also carried for the communication among each other Between the computer and printer a connection made by an intermission connection cable
30. during the start up self test even the test is successful UPS stays at this mode In order to pass on line mode you need to push T button once if you bring the manual bypass switch to I position when the bypass input voltage is out of allowed limits then the ups switches to shutdown mode but the loads are still kept supplied through manual bypass line 5 1 1 5 Inverter Failure INVFLR If there is a failure UPS pass to INVFLR mode If failure happens during the on line operation UPS passes to by pass mode If by pass input is not available it gives OUTFLR When you see the UPS in INVFLR operation take out the load and try to start up the unit CE maximum two times If it does not work please contact to technical service 5 1 1 6 Output Failure OUTFLR If there is any possibility to damage the loads UPS passes to OUTFLR mode UPS shuts down the output and loads are not supplied CS During the OUTFLR operation UPS is not switched off there is no output voltage only Possible reasons ate listed below During the on line operation short circuit happens at the output and continues more than 100 ms Due to conditions UPS try to pass to b pass mode but the by pass input voltage is not within the acceptable limits During the INVFLR operation UPS try to pass to by pass mode but does not succeed Sensing of too much over temperature during shutdown mode When the UPS is on OUTFLR operation 0 sign appears on
31. e fuse between load and UPS must be lower than the fault clearing capability value given in the Technical Specifications chapter Otherwise fuse shall not be triggered before 10ms and load energy shall be interrupted Before making output connections switch on to 0 position the automatic fuse on the distribution box UPS input output battery and by pass if any additional battery cabinet if any automats Load will be connected L2 N2 and ground earth connections at the rear side of the UPS A A 3 4 6 Cables dimensions between UPS and loads have to be chosen following load current Load power connected at the UPS output must be not bigger then UPS nominal power Communication Interface Connection Please contact to authorized Inform distributor to get the optional accessories such as SNMP adapter modem remote control panel software etc Information about this section is given in the communication interface section 288713578 10 4 Switch on and Switch off 4 1 Switch on After making all the connections mentioned in the chapter 3 you need to switch on to I position the automatic fuse on the distribution box all fuses on the UPS including the external battery cabinet if any except the manual bypass switch If mains voltage is within the limits the unit switches on UPS makes self test fot few seconds to check if everything is normal and then starts to supply the load If you want to
32. e if the junction temperature passes over a certain value than it transfers the load to by pass line assuming the bypass voltage is acceptable before the calculated time which has been found out with the help of thermal model Overload time versus overload quantity diagram is shown in the technical specifications section of the user manual If the unit is working on by pass mode during the initial start of the overload or if it has passed to by pass mode because of the overload than the only protection in the system is the automatic fuses in the circuit In case of the UPS fuse is switched off than all the loads on the output shall be without energy E For safe operation avoid the system from overloading 5 1 4 2 Output Short Circuit If a short circuit occurs at the output of the unit UPS acts like a current source as long as the over current is drawn it decreases the output voltage keeping the output current constant at a certain value forcing to trigger the fuse that is between the UPS and the short circuited load By triggering the mentioned fuse the short circuit is being removed and the loads are being prevented to be affected from this failure The unit performs the short circuit protection facility in case all the loads are connected to the CE circuit with a separate fuse suitable to their nominal current value and it is working at on line or battery mode during the short circuit event If the short circuit happen
33. echnical setvice In case of emergency damage of the cabinet front panel or connections etc switch off the UPS cut off input voltage and inform authorized technical service Please make the necessaty packing if it is obligatory to move the UPS 288713578 1 2 System Description On line UPS connected between mains and load protects the load against voltage fluctuations ripples and electricity cuts off Our UPS during the on line operation provides stable pure sine wave This pure sine wave is not affected from the input voltage fluctuations This helps to extend the life time of your sensible loads Power factor of the current consumed from the mains is nearly one You do not have any problem on generator or isolation transformer applications Your reactive energy consumption decreases Over 130V mains voltage smart battery charger charges the batteries Batteries do not need any maintenance In case of longer overload or inverter failure situation UPS transfers the load to by pass line and load is supplied from the mains When the normal conditions come back UPS shall continue to supply the load through inverter UPS control and management is done by digital signal processor DSP which is 200 times faster than standard microprocessors This helps to make your UPS smarter DSP uses all the sources on optimum conditions observes the failure conditions and communicates with your computer system UPS has standard communicatio
34. ection through the automatic fuse and neutral to N1 connection Before connecting the input cables switch on 0 position the automatic fuse on the distribution box Cables to be used for UPS and distribution box connections are shown in the chapter 9 Risk of fire IEC 62040 3 EN 50091 3 standard suggests to put below sticker next to automat that UPS to be connected in the distribution box against the risk of leakage reverse voltage Otherwise can cause life risk gt e e 288713578 7 AN Isolate uninterruptible power supply before working on this circuit 3 4 3 By pass Input Connection There is no need to make any connections at non split by pass type Please follow up the below instruction for split by pass type Please add two poles automatic fuse to distribution box where to UPS is to be connected Please do not forget to add leakage current relay Fuse value amp type is stated in the technical specifications section of the user manual Leakage protection relay value must be the total value of 30 mA UPS input leakage current relay and total leakage current value of the load connected to UPS Relay must be protected type against peak current that can be happened on EMI filter capacitor Above informations are given for the supply of UPS only If more equipment will be supplied please make the calculations accordingly AN Changes on distribution box have to be done by authorized persons only After the nece
35. ed as an accessory 288713578 19 UPS free contact connector PC Serial female communication port ec 9 9me o Oo LJ 2 L 3 L 4 5 LI menuerne 5 1 3 5 2 Communication via serial port RS232 serial communication port is connected to 9Pin D SUB male connector Pin connections are as follows GND Pin 5 TXD Pin3 RXD Pin2 The remaining pins do not have any connection In the below diagram computer serial communication connection via RS232 is shown as an example UPS free contact connector female PC serial communication serial port male communication connector male RS 232 female mm female 288713578 20 5 1 4 Abnormal Conditions Operating Principles 5 1 4 1 Overload Connection of loads to the output of the UPS that exceeds the nominal power of the unit is called Overload UPS can feed the load that exceeds the nominal power of the unit for a limited period while operating online This period depends on the load quantity and the initial temperature of the overload on the semiconductors The Unit follows up the following procedure in the calculation of the overload time It feeds the load for a period which will not cause the output fuses to blow out using a thermal model which has been formed by considering the output fuses thermal characteristic than it transfers the load to by pass line if the bypass input voltage value is within the allowed limits Meanwhil
36. ed when the unit is at Shutdown mode ONLINE It is observed when the unit is in On line mode BATTR It is observed when the unit is working from the batteries BYPASS It is observed when the unit is working from the mains via by pass line WTMNS It is observed when the unit is on mains waiting mode INVFLR It is observed when there is a ups inverter failure OUTFLR It is observed when there is a failure at the output 288713578 22 If the mains voltage goes out of the limits during green mode operation at the units having split by pass than UPS starts its rectifier for in case that the by pass input might go out of limits in E order to keep ready the transfer from the direct current in the input of inverter to batteries without any interruption Briefly it passes to battery operation mode But at the same time it also remains at by pass mode This is an exceptional situation where the equipment remains on two modes at the same time and meanwhile on the LCD display BYPASS message is observed The type of operation is shown on the LCD display with the following messages O As an operation mode it shows that UPS out of circuit has been selected G As an operation mode it shows that Green Mode has been selected N As an operation mode it shows that Normal Operation has been selected Below the OPERATION TYPE part there is manual bypass indicator location When the ups supplies the load through manual bypass line then
37. ely Cg Itis suggested to use normal operation During the out of function mode load is not fully protected against output short circuits and mains disturbances To pass to on line mode operation from the out of function mode operation please push the T button Two times if there is an audible alarm One time if there is no audible alarm To pass to green mode operation from the out of function mode operation please push the I button Three times if there is an audible alarm Two times if there is no audible alarm 5 1 2 4 Manual Bypass Operation Manual bypass facility is used to disconnect the load from ups output and transfer it to the bypass line without interruption mainly for maintenance purposes The following procedure should be followed up in order to transfer the load to the bypass line without interruption The ups should be operating at ONLINE mode observe the ONLINE OK N message on the front LCD display panel e From the front LCD display panel pass to GREEN MODE operation by pressing the I button Observe the BYPASS OK G message on the front LCD panel e Bring the manual bypass switch to 1 position e Observe the MB message on the bottom line of the LCD panel e Bring the output input bypass battery charger and battery fuses to 0 position and be sure that the ups is switched off Now the loads ate supplied through the manual bypass switch and in case of a bl
38. ery capacity goes below 30 Other than these conditions it does not lits By pass This Yellow LED lits during by pass operation mode Overload This Green LED lits continuously during normal load conditions t starts blinking whenever an overload condition occurs Inverter This Green LED indicates that the inverter is working properly and the loads are fed through inverter xxx It does not lit if the inverter fails Fault This Red LED starts blinking whenever the following situations occut o If the unit s cooler or junction temperature has exceeded a certain value o If the environmental temperature has exceeded a certain value o Ifthe battery voltage has exceeded a certain value o Ifthe Fan has failed o Ifthe Battery Fuse has been switched off or turned to 0 position o Ifthe Battery Test has failed o Ifthe Unit has passed to Inverter Failure Mode o Ifthe Unit has passed to Output Failure Mode Other than these conditions it does not lit 5 2 1 3 Buttons There ate four buttons present on the front panel of the unit The functions of these buttons are explained below 0 button It is used to switch off the UPS functions of the equipment I Button This button has three functions o To restart the unit if it is in Shutdown mode o To silence the audible alarm if present o To change the operating mode of the unit as Green or Normal Operation When I button is pressed the equipment implements one of the func
39. gain If you want to make all the connections first you should run the UPS in a way to avoid battery mode after making all connections then switch to I position the fuse on the distribution box UPS battery input output and by pass if any automats UPS starts on line operation mode During the first charging in order to prevent the UPS to pass battery mode in case of a sudden electricity cut please push 0 button At the end of suggested charging time you may press the I button in order to select the required operation mode 288713578 9 3 4 5 N In order to prevent the UPS to pass battery mode the 0 button has been pressed therefore in case of an electricity cut off before the end of the offered initial charging time then the ups is switched off and the loads are disenergised Before starting to do the output connections after the advised initial charge time please perform the followings e Bring the ups input fuse to 0 position e Bring the ups battery fuse and external battery cabinet if any fuse to 0 position e Bring the fuse of the main distribution panel that the ups is connected to 0 position Now you can do the output connections Output Connection It is suggested to use different fuse and leakage current relay for each independent load In case of short circuit related fuse will be triggered and remaining loads shall continue to be supplied Nominal current value of th
40. ght AN If needed to move the UPS it is obligatory to pack the unit It is suggested to keep the original packing 3 2 Storage Please store the UPS in an environment where the temperature is between 25 C 55 C no receipt of direct sunlight far from the heating in a dry place Environmental humidity must be between 20 95 none condensing If the batteries will be stored more than 3 months it is suggested to charge the batteries periodically Relation between storage temperature and period is shown below Storage temperature below 20 C once per 9 months Storage temperature between 20 C and 30 C once per 6 months Storage temperature between 30 C and 40 C once per 3 months Storage temperature above 40 C once per 2 months Please follow up the instructions of installation chapter for earth input and battery connections Please turn to T position UPS s input fuse and also additional battery cabinet fuses if present Please charge the batteries at least 12 hours 288713578 5 3 3 Positioning UPS and battery cabinet 1f any have to be positioned in an environment e No direct sun access Dry e Far from the heating equipments e Well ventilated e No excessive dust In order to maintain adequate ventilation of UPSs and battery cabinet ensure the air vents are not blocked and leave at least 20 cm space at the rear side of the unit for ventilation Even though the operating temperature
41. i a gue toeq de thai e Deua Pe anaes i 3 4 3 Bypass Input Connection cce tenete fece pee te abe te ete hina te ie iet patet ette uada 8 3 4 4 Battery Connection 3 4 5 Output Connection 3 4 6 Communication Interface Comme ctr iei itc siete ie A ed ee ree EU CHER detto Ee eet haue Switch on and Switch off AT Switchonisccnsteeneentc a acia e e Tee re b rH ES Tu o adden ere ea tace de anon Rete RUD 11 42a Sitet OE e 11 Operating Instructions 2 si icccdsscedsecsctecascssaedncsestessdesduebencsstesevesdunkasceddesevessbabesessdesavssiaclesssdbesaiarseataasssdess 12 Dali Unit Operatives tie MG 12 5 1 1 Operating MOES tes ciet EAE EE RAE EEE aen tud de Decet eda eoe eed teet u D egeo eoe eade 12 SUKE On line Mode ONLINE S 2 5 1 1 2 By pass Mode BYPASS ttis 2 5 1 1 3 Battery Mode BATTR 13 5 1 1 4 Shutdown SHUTD t ttis 3 515 Inverter Failure IN VELR ERNE 4 5 1 1 6 Output Failure OUTFLR 14 5147 Wat ney Ne ee 5 5 1 2 CG erating Ai esas csv RR 15 5 1 2 1 Online Priority Operating Normal Operation uses 15 5 1 2 2 By pass Priority Operating Green Mode 5123 UPS out Of Function 512 4 Manual Bypass Operations ose oak etnies eal vein Baa eto ciation Verri ee id s Dep rege aa rae ees d Seige sal 5 1 3 Operating Reaturesiand ValS isisisi iaria eee d HR e n Rd v et ee eco ded 5 1 3 1 Online Mode and Voltage Tolerance g
42. ical Specifications Height 68 cm Width 27 cm Depth 67 cm Weight 48 4 kg Environmental Conditions Temperature PREME 0 40 PC Relative Humidity Cree ih acs Storage 15 55 PC Storage 9 920 9 995 Electrical Specifications System Efficiency with Input voltage 220 V and full capacity batteries 0 0100 linear 50 linear 7 9100 non linear 50 nonlinear Load Load Load cos 0 7 Load cos 0 7 Normal Operating online mode gt 91 7 gt 90 3 gt 90 4 gt 89 3 Green Mode by pass mode gt 96 0 gt 93 8 gt 95 9 gt 93 6 Cross Sections of Connection Cables Ground Connection 10 mm Input phase amp neutral 10 mm 2 By pass connection 6 mm Output phase amp neutral 6 mm Battery 6 mm Input Phase Number 1 Nominal Voltage 220 V Nominal Frequency 50 Hz Input voltage range at mains running lt 43 Load 80 280 V Full load 159 280 V Input frequency tolerance 45Hz 65Hz Input current Limit 32A Fuse current and type 32A C Type Powet factor at nominal input voltage Full load 20 990 Half load 20 970 Current Total Harmonic Distortion THD 100 linear Load at nominal input voltage lt 6 0 Output online amp battery Operation Phase number 1 Voltage wave form Sinusoidal Nominal Power kVA 5000 VA Nominal active power 3500 W N
43. ion Clean the unit with a slightly moistened cloth AN Do not drop any liquid and solid foreign substance inside the unit AN Do not use a cleaning powder or any other material that may damage the plastic parts 288713578 28 8 Trouble Shooting In this section the procedures that should be followed is explained during an abnotmal condition of the unit Before you infotm the technical service read and apply carefully the things explained in details in this section Before informing the technical service Be sure that you have read this section completely amp carefully and applied all the things that are advised Please note the model and serial number of the unit which are present on the rear panel label Describe the problem with full information If you think that there is a problem on the unit than initially perform the following controls on the unit Has the earthing connection of the unit been made correctly Has the input fuse of the unit switched off You should do the earthing connection as explained in the related section in order to run the ups propetly At the systems that do not have a split separate By pass input a switch off on the input fuse indicates that there is a short circuit occurred on the output duting by pass mode operation or a failure occurred on the ups In such a case you should do the followings After you turn the output fuse to 0 position turn the input fuse to I position and sta
44. l input voltage Full load gt 0 973 Half load gt 0 949 Current Total Harmonic Distortion THD 100 linear Load at nominal input voltage lt 6 9 Output online amp battery Operation Phase number 1 Voltage wave form Sinusoidal Nominal Power kVA 3000 VA Nominal active power 2100 W Nominal voltage 220 V Nominal current 13 6 A Frequency mains present Locked to the input Frequency normal run 50 Hz 0 005 Power factor 0 7 Crest Factor at nominal power 3 1 Static voltage regulation 0 100 load variation 01 Voltage Total Harmonic Distortion THD 7 0 Load 0 9 25 linear Load lt 1 3 25 non linear cos 0 7 load lt 2 2 50 linear Load lt 1 8 50 non linear cos P 0 7 load 1 5 75 linear Load lt 2 2 75 non linear cos 0 7 load lt 2 0 100 linear Load lt 2 5 100 nonlinear cos 0 7 load lt 3 6 Overload holding time 0 to 150 load variation 63 s NOTE Overload holding time is a software parameter and can be changed upon request Fault removal current For B type fuse 6 A For C type fuse 3A 288713578 31 By pass Line Phase number 1 Nominal frequency 50 Hz Nominal power kV A 3000 VA Nominal active power 2100 W Nominal voltage 220V Nominal current 13 6 A Fuse value used in the panel 16Amp C type Bypass input voltage range 198V 242V Bypass input frequency range 47Hz 53Hz NOTE By pass voltage and frequency are software parame
45. n interface Using Inform software you may protect your data and operating Systems UPS block diagram is shown below MANUAL BYPASS SWITCH INPUT BOOST TYRISTOR RECTIFIER OUTPUT FUSE INVERTER INVERTER TYRISTOR INPUT FUSE BATTERY TYRISTOR BATTERY CHARGER BATTERY FUSE BATTERY 288713578 2 Input Thytistors This helps to cut the energy flow between the UPS input and boost rectifiers during the battery mode or battery test Boost Rectifier On mains operation the boost rectifier adjusts the mains voltage to the necessary DC voltage level required for the inverter and helps to provide sinus current with a power factor near to 1 from the mains On battery mode it increases the battery voltage level required for the inverter and uses current from the battery with a low ripple ratio thus extending the battery life Inverter The inverter helps to obtain a very constant AC voltage level at the output by using DC voltage at the boost rectifier s output Inverter Thyristors This helps to separate inverter from the output electronically in case of by pass mode operation ot UPS output off conditions Your UPS features Feature Benefit Battery Thyristors This helps to separate battery from the boost rectifier electronically Battery The necessary energy is supplied from the batteries when the mains is not available Manual By pass Fuse This is an automati
46. nnect some of the loads The procedures that should be followed up are summarized below in case the UPS passes one of the below failure modes INVFLR Inverter Failure mode o Disconnect all the loads safely o By pressing the T button twice try to restart the unit again o Call the technical service if the same failure happens again 288713578 29 OUTFLR Output Failure mode o Check the loads Disconnect the excess loads and short circuited loads if any o Check the environment temperature be sure that there is enough ventilation space around the ups o Check the Fans whether they are running properly or not if there is a problem on the fans than call the authorized staff o By pressing the T button try to restart the ups If the failure happens again than call the authorized staff During the normal operation of the ups the possible situations that can be faced and the things that should be done in such situations are explained details in the following Trouble Shooting Chart Y Battery voltage is low After obtaining the data security switch off the loads Is it at BATTR mode Is there a BUV alarm As a running mode normal is selected Unit is online working There is exceeding load in the circuit Disconnect the unnecassary loads Is there a OVLD alarm As a running mode Green Mode is selected The unit is working at By pass Mode Cooler or junction temperature is
47. of the mains supply and distribution panel if any to P position e Operate on green mode e When you observe the G letter on the upper right side of the LCD panel bring the manual bypass switch to I position Brine the output fuse to T position g P P e Bring the fuses between to ups and the loads to T position ce The loads ate not protected during the initial charge period against the disturbances and blackouts at the bypass input due to the supply through bypass line After the completion of the advised recharge time e bring the manual bypass switch to 0 position e Switch the ups from green mode operation to online normal operation If you want to do the initial charge without connecting the loads to the output than please follow up the below instructions Bring the fuses of input and battery to T position Bring the fuse of external battery cabinet if any to I position e Bring the fuse of the main distribution panel if any to T position AN Do not touch any Clemens or terminal during the operation For your own safety please make the output connections according to the instructions described in the related section after the end of the initial charge time guarantee the UPS not to pass to battery mode in the next cut off it is necessary to press 0 If the mains cut off and comes back again during the initial charge of the batteries in order to button a
48. ominal voltage 220 V Nominal current 23 A Frequency mains present Locked to the input Frequency normal run 50 Hz 0 005 Power factor 0 7 Crest Factor at nominal power 3 1 Static voltage regulation 0 100 load variation 91 Voltage Total Harmonic Distortion THD 76 0 Load 0 8 25 linear Load lt 1 6 25 non linear cos 0 7 load lt 2 1 50 linear Load lt 1 5 50 non linear cos 0 7 load 2 1 75 linear Load 1 8 75 non linear cos 0 7 load 25 9 100 linear Load 24 100 nonlinear cos 0 7 load 35 5 Overload holding time 0 to 7 0150 load variation 63 s NOTE Overload holding time is a software parameter and can be changed upon request Fault removal current For B type fuse 9 6 A For C type fuse lt 48 A 288713578 33 By pass Line Phase number 1 Nominal frequency 50 Hz Nominal power kV A 5000 VA Nominal active power 3500 W Nominal voltage 220 V Nominal current 23 A Fuse value used in the panel 25Amp C type Bypass input voltage range 198V 242V Bypass input frequency range 47Hz 53Hz NOTE By pass voltage and frequency are software parameters and can be changed upon request Transfer Time 0 ms Batteries Battery type Sealed Maintenance free lead acid The quantity and capacity of batteries located inside the ups cabinet
49. ptional case that UPS is on two modes at the same time Split by pass type During on line mode and mains input is out of the limits UPS passes to battery mode If there are no other abnormal conditions Necessary energy to operate the inverter is supplied by the battery During green mode both mains input and by pass input are out of the limits UPS passes to battery mode Necessary energy to operate the inverter is supplied by the batteries During green mode mains input only is out of the limits inverter is supplied from battery but load is supplied from the by pass line Standard type During on line mode and mains input is out of the limits UPS passes to battery mode If there are no other abnormal conditions Necessary energy to operate the inverter is supplied by the battery During green mode and mains input is out of the limits UPS passes to battery mode If there are no other abnormal conditions Necessaty energy to operate the inverter 1s supplied by the battery You may switch on the UPS by pushing CS button even if mains input is lower than 130 V or input fuse is on 0 position In this case UPS switch on shutdown mode and make self test If everything is ok UPS operate on battery mode Autonomy time depends on battery type quantity and load level UPS stops feeding the loads if the battery voltage falls under a certain value Battery life decreases if battery capacity falls below a certain level
50. re of semi conductors Calculation is done as follows gt Load is supplied for a certain period by UPS considering output fuse temperature characteristics and if by pass input voltage is available and then pass to by pass Meanwhile if junction temperature passes the critical level if by pass input voltage is available then passes to by pass Non moving parts except the fans Maintenance free lead acid battery usage Less maintenance need Communication interface Using Inform software you can protect your data and operating Systems Uninterruptible manual bypass The ups can be transferred to bypass line by manual by pass switch without disenergizing the connected loads Output voltage is not affected by changes on the mains input and load level High efficiency Low power consumption 288713578 3 Installation ge Check if the UPS has been subjected to any damage before unpacking it If you notice any damage please contact to transport firm Check if all the additional patts have been supplied with the UPS Please make sure that the packing contains the following UPS User Manual Test Reports Cg Before the installation please check if your UPS is customized following your special requirements if any CS In standard UPS output voltage and frequency are adjusted to 220 V 50 Hz 3 1 Handling UPS and battery weights are given in the chapter 9 You may calculate the total wei
51. rt up the ups normally See the ONLINE OK message on the display than turn the output fuse to T position If there is a short circuit at the output and if all the loads are connected to the output via suitable valued fuses than the ups finalize the short circuit by switching off the fuse that belongs to short circuited load If the loads are not connected to the output via suitable valued fuses than the unit passes to OUTFLR mode In this case the short circuited load should be found and disconnected from the system In otder to run the ups at Online mode the input voltage should be within a certain value range If the input fuse switches off again although the output fuse is on 0 position than please call the technical service The list of the alarms that can be seen on the unit and their definitions have been explained in the Display LCD section The followings should be applied if you see these alarms FANFLR Fan Failure Call the authorized staff BOVTE Battery temperature high Bring back the environmental temperature to normal BUV Low battery voltage Wait for the mains voltage to come back normal situation BFUFL Switched off battery fuse Turn the fuse to T position If it switches off again than call the authorized staff OVTE Over Temperature Failure Switch off the loads and maintain the normal environmental temperature 1f the alarm is seemed again than call the authorized staff OVLD Overload Disco
52. s during on line mode and continues more than 100ms then the unit passes to OUTFLR mode If the short circuit happens duting battery mode and continues more than 100ms then the unit shut down itself 5 1 4 3 High Inrush Current Load at the Output Some loads absorb more current than their nominal current value for a short period of time when they are energized Ordinary UPS s either switch off their output and they cause all the loads to remain without energy or they pass to by pass transferring all the loads to mains Our system behaves like a current source in such a situation As long as the over current is drawn it decreases the output voltage keeping the output current constant at a certain value Thus none of the loads on the output are affected from this situation CS UPS performs this feature if it is working in online or battery mode 288713578 21 5 2 Display 5 2 1 Front Panel The front panel of the ups is shown below By Pass Fault Inverter Overload The front panel is composed of 3 parts These are LCD Liquid Crystal Display LED Indicators Buttons 5211 Display LCD There are four sections on the ups Display These sections are shown below OPERATIOH MODE ALARM OPERATIOH TYPE MAHUAL LUE VARIABLE NEM BYPASS IHD On the Operation mode section of the Display the actual operating mode is seen On the display panel the following messages can be observed SHUTD It is observ
53. ssary changes switch on 0 position the automatic fuse on the distribution box and connect the phase to by pass connector through the automatic fuse and neutral to N1 connection AN Before making by pass connection switch on 0 position the automatic fuse on the distribution box 3 4 4 Battery Connection If the batteties are installed inside the UPS cabinet there is no need to make battery connections If the batteries shall be put in a separate additional battery cabinet or make parallel to the batteries inside the UPS please follow up the instructions below Switch on to 0 position the battery cabinet fuse Connect the B on the battery cabinet to B on the UPS Connect the B on the battery cabinet to B on the UPS Connect the N3 on the battery cabinet to N3 on the UPS Connect the PE on the battery cabinet to battery ground earth on the UPS 288713578 8 In order to obtain better performance from the battery please charge at least 10 hours before the se operation The initial charge of the batteries can be done with connected load at the output But in order to perform this the following procedure should be followed up e Perform the output connections as described in the related section e Bring the position of the external battery cabinet fuse to I position if it exists e Bring the battery fuse of the UPS to T position e Bring the input fuse of the UPS to T position e Bring the fuses
54. switch on the UPS when the mains is out of the limits please press CS button 4 2 Switch off To switch off the UPS please press 0 button Then the load is transferred to by pass If the mains is out of the limits UPS pass to shut down mode To stop the load to be supplied please turn the UPS output fuse to 0 position To switch off the UPS please turn all the fuses to 0 position Even though all the fuses are in 0 position there is still energy on the connections Do not touch AN If any work will be done on UPS connections fuses on mains by pass distribution box if any battery cabinet if any must be turned to 0 position y y Y P Devices with internal batteries have hazardous voltages on battery connectors even if the battery circuit breaker is in 0 position Do not touch these connectors 288713578 11 5 Operating Instructions 5 1 Unit Operation 5 1 1 Operating Modes Following the status of mains amp by pass voltage UPS can operate either one of the below operating modes Cg Considering standard non split by pass type UPS by pass input and mains input voltage means the same thing 5 1 1 1 On line Mode On line Online mode is available if the mains is within the allowed operating limits In this mode UPS supply the load and charge the batteries when the mains voltage is over 130V Load is supplied through inverter and inverter is on line If On
55. t Most probably there is a failure on the unit Disconnect all the loads and By using the T button start the unit If the same situation repeats again than call the technical service Inform the technical service 288713578 9 Technical Specifications 3kva Saver DSP Physical Specifications Height 68 cm Width 27 cm Depth 67 cm Weight 43 1 kg Environmental Conditions Temperature PREME 0 40 PC Relative Humidity Cree ena Storage 15 55 PC Storage 9 920 9 995 Electrical Specifications System Efficiency with Input voltage 220 V and full capacity batteries 9 5100 linear 9 550 lineat 100 non linear 50 nonlinear Load Load Load cos 0 7 Load cos 0 7 Normal Operating online mode 291 6 290 3 290 9 290 2 Green Mode by pass mode 296 6 2944 296 3 2944 Cross Sections of Connection Cables Ground Connection 4mm Input phase amp neutral 4mm By pass connection 2 5 mm Output phase amp neutral 2 5 mm Battery 6 mm Input Phase Number 1 Nominal Voltage 220 V Nominal Frequency 50 Hz Input voltage range at mains running lt 41 Load 80 280 V Full load 160 280 V Input frequency tolerance 45Hz 65Hz Input current Limit 24 A Fuse current and type 20A C Type Power factor at nomina
56. t 5 132 Bypass Mode Voltage Tolerance uccisi nin HENRI II ire ee iret T IT N 5 1 3 3 Battery Management and Autonomy Time entente teen tennttenttentteennnnn 18 5 1 3 4 Temperature Management s Sags Communicatior Interface teas Lees acsscosccasecenseceseseusseadeueddusesidedtsscosccsnecensccnscgeuecetioned 5 1 4 Abnormal Conditions Operating Principles serne ennen nn 21 SRLS xOvedoadissieisse NRI RTI USER qu ERRARE ERR RR Ren 21 Dil A Qe tGOUEIDUEODOEE COIECUIE sccsssosesceessiessensconssacsietsaseisssessesssosssssedseesos essenssotssheesdesssedssssas asssedsissss idccasscesseeussensccessechsstissc e 21 514 3 High Inrush Current Load at the Output ies teet terittre rerit ce HR RIA IR UAR AR EHE See Vect 21 52 gt Display M 22 5 2 1 Front Panel 22 5 2 14 Display LCD mo SFA MEN SED pM renen 24 RAM Er L M M B 24 522 AJatinssscece comua eI DELI EI LP I ERIOION Ee sedie Deu Ops ST OTST TD SE SSPE SORE STOTT 25 Important Operating Notices cccsssccsssssecesseeeecessnsecesssesecesseeeeeesseeecenseeeesesseeeecesseeesesseeeeseseeesenseeeeees 26 AED 28 Trouble Shooting Sa 29 Technical Specifications 3kva Saver DSP cccsssccsssscessscesecesecessesesseeceseeceseesessesessesenseeceseeseeesees 31
57. ters and can be changed upon request Transfer Time 0 ms Batteries Battery type Sealed Maintenance free lead acid The quantity and capacity of batteries located inside the ups cabinet pd e Ee wd NC 4 12V 7 Ah 2 4 kg 14 168 V 33 6 kg 12V 12Ah 4 1 kg 14 168 V 57 4 kg Apptoximate bridging times Full load 14 pcs 7 Ah battery 11 min Half Load 14 pcs 7 Ah battery 30 min Full load 14 pcs 12 Ah battety 25 min Half Load 14 pcs 12 Ah battety 63 min Battery Recharge Time 80 capacity for 7Ah App 5 Hours Battery Recharge Time 80 capacity for 12Ah App 8 Hours Temperature controlled battery charging General Specifications Audible Noise 1m away from the front of the unit 50 dB Isolated Free Contact communication and serial communication RS232 according to EN60950 At Normal Operation online amp battery operation electronic short circuit protection At Normal Operation online amp battery operation overload capability At Normal Opetation online amp battery operation capability of holding inrush currents Over temperature Overvoltage Over current and battery deep discharge protections Fan speed control present LCD Display Standards Protection Class IP 20 EMC EN 50091 2 Performance EN 62040 3 EN 50091 3 Safety EN 50091 1 288713578 32 10 Technical Specifications 5kva Saver DSP Phys
58. test UPS starts in this operation type The same is true if the UPS has been started up by pressing CS button in case of a mains interruption If the mains input is out of the tolerance UPS passes to battery mode When the mains input returns to normal conditions UPS passes automatically to on line operation Even though the mains input is within the operating limits but there are abnormal conditions such as over temperature continuous overload failure etc UPS passes to by pass operation if the by pass input is within the operating limits If the by pass input is out of the tolerance the unit either passes to shutdown mode or switch off If the unit passes to by pass mode when the abnormal condition is over UPS starts to online operation You will see on the right top of the screen as N sign indication during the normal operation 8 P 8 8 P Cg Normal Operation is the safest operating type Load is fully protected on normal operation only To pass to green mode operation from the normal operation please push the T button Two times if there is audible alarm One time if there is no audible alarm To pass to UPS out of function operation please push the O button 51 2 2 By pass Priority Operating Green Mode UPS operates on by pass mode if the by pass input is within the operating limits If the by pass input is out of the limits UPS check if the mains input available for on line operation then pass to on line
59. the front panel during installation Please follow the instructions as explained below 3 41 Ground Earth Connection AN UPS ground earth connections have to be done UPS input ground earth connector has to be connected to low resistive ground earth line Load ground earth connections have to be done through UPS output ground connector If any battery cabinet exists grounding has to be done through battery ground earth connector Minimum cable cross sections are given in the chapter 9 3 4 2 Input Connection Please add two poles miniature circuit breaker to distribution box where to UPS is to be connected Please do not forget to add leakage current relay It is suggested to add to a miniature circuit breaker that fits UPS input fuse value The value amp type of the fuses are stated in the technical specifications section Leakage protection relay value must be the total value of 30 mA UPS input leakage current relay and total leakage current value of the load connected to UPS Relay must be protected type against peak current that can be happened on EMI filter capacitor Above informations ate given for the supply of UPS only If mote equipment will be supplied please make the calculation accordingly gt Changes on distribution panel have to be done by authorized persons only After the necessary changes switch on 0 position the automatic fuse on the distribution box and connect the phase to L1 conn
60. tions respectively listed above Concerning all above functions If the function on the top is not possible to be implemented then it passes to next function For example if you press the I button when the ups is not in Shutdown mode than it seatches for an audible noise if existing where the unit is already working as online If there is an audible alarm than it silences this If not than it changes its operating mode CS Button It is used to start up the ups from the batteries whenever the input mains conditions are not available 288713578 24 MODE Button This button is used to identify the variable that is aimed to be displayed on the Variable section 5 2 2 Alarms The Unit gives an audible alarm in every two second on following cases During a fault alarm indication when the fault light is flashing During the battery operating mode During the initial start up test During battery test During the by pass operating mode although Green Mode operation option has not been selected During Overload condition You can press the I button in order to silence the buzzer but this does not mean that the problem that caused to activate the audible alarm has been fixed If you silence the buzzer as explained above you can not reactivate it as audible alarm format for the same type of problem that has activated the buzzer It is not possible to switch off the buzzer completely You can silence the buzzer by pressing the
61. too high Check the environment temperature decrease it if necassary Is there a OVTE alarm Is it at BYPASS The unit is running but the ouput is switched off With I button start the unit The air temperature in the air entrance of the unit is too high Check the environment temp decrease it if necassary Is there a BOVTE alarm Switched off by the comment received from Comm Interface It is on mains waiting mode It wil switch on automatically when the mains come back Battery test result is negative Inform the authorised staff Is there a BATTF alarm Battery fuse is switched off Switch on it If the same failure happens again call the authorised staff Is there a Check the connections and BFUFL alarm fuses than restart the unit Fan is not working call the authorised staff Is there a FANFLR alarm Is 0 written By pressing T button run the ups at normal mode Is it at BYPASS mode on the running type section Unit has passed to by pass because of some irregularities For a long time if it does not pass to online or battery mode or the audible alarm does not stop call technical service Unit has switched off its output temporarily because of a possible fixable problem The loads are unenergised After the Overload short circuit temperature controls and necassaty corrections by pressing I button restart the uni
62. ttery operation capability of holding inrush currents Over temperature Overvoltage Over current and battery deep discharge protections Fan speed control no LCD Display Standards Protection Class IP 20 EMC EN 50091 2 Performance EN 62040 3 EN 50091 3 Safety EN 50091 1 01 11 2005 The manufacturer has the right to change all the information in the user manual without any declaration 288713578 40
63. uld go down to 275V 5 1 3 2 By pass Mode Voltage Tolerance Factory configuration for by pass mode voltage tolerance is between 198 V 242 V 10 of the nominal input voltage You may ask to change this limit please contact to authorized Inform partner If the voltage is out of the above limits UPS does not work on by pass mode To come back on by pass mode by pass voltage has to be within between 203 V 237 V following the factory settings 5V lower limit and 5V upper limit 288713578 17 5 1 3 3 Battery Management and Autonomy Time UPS has smart battery management system To be able to charge the batteries the mains voltage being 130V 280V range is enough Charge voltage is free from load Autonomy time is an immeasurable quantity UPS calculates and shows battery back up time thanks to artificial intelligent algorithms Bridging time depends on battery capacity and quantity load level battery charge level status Autonomy time values which are calculated while the UPS is operating in battery mode are mote accurate than those calculated while UPS is operating in another mode Please check chapter 9 to see the back up time of a fully charged on full and half load conditions In order to obtain longer autonomy time you may add batteries either internally if possible or in an external battery cabinet Please contact to authorized service During the discharge battery mode current ripple is on minimum level UPS h
64. uring bad weather such as lightning conditions 5 1 3 5 1 Free Contact Communication UPS 9 Pins D SUB female socket free contact gives the following signals UPS shutdown This feature is used for remote shutdown and switch on via PC Pin 6 high 5V 12V Pin 7 0V Mains failure This signal between Pin 2 and Pin 4 contact closed is given if the mains input is out of the allowed operating limits and disappears when the mains input comes to its normal conditions Low battery This signal between Pin 5 and Pin 4 contact closed is given if the battery capacity is less than 30 By pass active This signal between Pin 1 and Pin 4 contact closed is given if the load is supplied by the by pass input Summary alarm This signal between Pin 8 and Pin 4 contact closed is given if battery mode low battery by pass active or Fault sign is blinking An example of free contact communication is given below If the system in communication sends DC signal in order to cut the current R resistors must be over a value If the voltage at the DTR end of the communicated system is 12VDC than the offered resistor value is 12 kQ With this method the required resistor value can be easily calculated depending on the DC voltage value exp 5V refer to 5kQ If the current which will be carried by the contacts is greater than 0 1m4A it is necessary to use the DSP UPS relay interface board stock code 105430016305 which can be purchas