HSK-320Z User`s Manual

image

Contents

1. homescenario 2 Keep the program button pressed the LED will turn off after 5 sec 3 Release the program button RS 485 Command When UART mode of configuration is set to 1 the HSK 320Z can be controlled via RS 485 bus RS 485 command can simulate input port high low event to send Z Wave command to devices in a group RS 485 command also can control 4 output ports in output mode or control motor up down stop in motor mode The RS 485 command is 9 bytes OOOO CO Leading byte must be hex value CO C1 Ending byte must be hex value C1 id RS 485 ID must conform with Z Wave configuration parameter 12 len Length of packet Must be 9 type Must be 45 rep Must be 0 port Must be 0 dev 1 to 5 for Z Wave command E1 to E4 for I O port See the following table val Command value See the following table Table 6 RS 485 command parameter dev val function 1 5 0 99 255 Z Wave command BASIC_SET with command value to group 1 5 128 Z Wave command SWITCH_MULTILEVEL_START_LEVEL_CHANGE with up direction Z Wave command SWITCH_MULTILEVEL_START_LEVEL_CHANGE with down direction SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE fered fo Turn off output port 1 4 local output port Turn on output port 1 4 local output port ei rs CE Motor Down local output port homescenario 130 Motor Stop local output port
2. homescenario HSK 320Z User s Manual Revision 1 0 Initial draft 1 1 Change the association groups 1 2 Add dimmer mode 1 3 Add sensor binding commands Introduction The HSK 320Z is a multi function I O module of Z Wave It can be connected to relay board to control up to four ports or be connected to sensor to trigger Z Wave command to a group of devices The HSK 320Z also features motor control to control curtain or roller blinds In addition the HSK 320Z can be used as Z wave to RS 485 bridge The 4 output ports and Z Wave group can be controlled by RS 485 command Connection There are 4 I O ports on HSK 320Z The 4th port is shared with RS 485 function If RS 485 is enabled the 4th port is disabled automatically The 4 I O ports can be configured as input or output together If the HSK 320Z is configured as input mode only input ports are functional please remove all connector from output ports If HSK 320Z is in output mode only output ports are functional please remove all connector from input ports Each input port accept input level from Ov to 3 3v The input port is non isolated please be careful of the input voltage If the input port is opened non connected it is normally in high status pulled high to 3 3v If the input port is connected to ground it is in low status Each output port is isolated solid state relay output Maximum current of relay is 500mA maximum voltage of relay is 48v
3. Z Wave Network The HSK 320Z is a Z Wave slave device To include or exclude HSK 320Z to a Z Wave network please click the program button beside DC power jack Device Mode Configuration The HSK 320Z support 4 modes homescenario TA 1 All T im of eee Mode Type Display Description Input LED 1 All 4 ports are in input mode Any change of input status will mode light trigger Z Wave command sending to group Output LED 2 All4 ports are in output mode Use Z Wave command to control mode light each port This mode will handle the BASIC_SET BASIC_REPORT SENSOR_BINARY_REPORT as well All 4 ports are in output mode Port 1 2 3 sends pulse to control motor up stop down 4 Motor hold LED 4 All 4 ports are in output mode Port 1 and 3 hold it s status to mode light control motor up and down 5 Dimmer LED 1 For 1 10v dimmer module In this mode we will send RS mode blink 485 dimmer command when any of the four input channel are connected Send RS 485 packet by Z Wave command To configure mode of HSK 320Z 1 Push program button before plug power hold button until LED is on about 1 sec 2 Release program button then LEDs turn on alternated Push the button again when desired LED device mode is lighting or blinking See table 1 to select a desired mode 3 If selected mode is 3 or 4 you can run motor calibration now see the Motor Calibration section If you don t want to run calibration p
4. 102 is disabled A reversed action is taken to stop motor controller 2 102 is disabled A toggle action is taken to stop motor controller homescenario nea default 0 For Motor mode 1 2 only valid 0 1 1 HSK 320Z will stop the motor according to the Run Duration automatically when motor reach top bottom 0 No auto stop Switch All default 0 For Motor mode 1 2 only valid 0 exclude on off 0 1 2 255 1 exclude only on 2 exclude only off 255 enable on off 0 RS 485 is disabled The IO port 4 is available valid 0 1 1 RS 485 is enabled The lO port 4 is unavailable default 96 96 RS 485 baud rate is 9600 BPS valid 38 RS 485 baud rate is 38400 BPS 38 96 115 115 RS 485 baud rate is 115200 BPS RS 485 ID default 0 For Input Mode only valid 0 255 ID of RS 485 If ID is 0 the HSK 320Z ignores ID of RS 485 commands accept all command Output valid 0 1 0 Output port is NO normally open 1 Output port is NC normally closed 12 14 Inverse Input default 0 For input mode only valid 0 1 0 Input port is low active 1 Input port is high active 15 RS 485 Map For RS 485 bridge mode Type 16 Dim curve default 33 threshold 1 17 Dim curve default 66 threshold 2 Inverse default O For output mode only Dim step 2 default 1 Dim step 3 default 1 Factory Reset To reset the HSK 320Z to factory default 1 Push program button before plug power hold button until LED is on
5. any of port 1 to 4 is changed from high to low SCENE_ACTIVATION_SET with port number 1 to 4 will be sent to all devices in related group a homescenario Z Wave Configuration Table 5 Z Wave Configuration parameters of HSK 320Z Parameter Value Description Range Device Mode default 1 Device mode valid 1 to6 1 Input mode 2 Output mode 3 Motor mode 1 pulse 4 Motor mode 2 hold 5 6 Run Duration default 600 Motor progress duration unit in 0 1 sec valid Valid value 10 6000 1 sec to 600 sec 10 6000 Default value 600 60 sec Pulse On default 30 On duration of the pulse under motor mode 1 unit in Duration valid 1 255 10ms Valid value 1 255 10ms to 2 5sec Default value 30 300 ms Pulse Off default 30 Off duration of the pulse under motor mode 1 unit in Duration valid 1 255 10ms Valid value 1 255 10ms to 2 5sec Default value 30 300 ms Hold Rest default 30 Rest duration of two contiguous action under motor mode Duration valid 1 255 2 unit in 10ms Valid value 1 255 10ms to 2 5sec Default value 30 300 ms Stop Before default 1 For Motor mode 1 only Reverse valid 0 1 1 If the desire action is reversed from current action the HSK 320Z will stop the motor automatically before reversed action 0 Desired action will be executed immediately Stop Type default 0 For Motor mode 1 only valid 0 1 2 0 Use 102 to stop motor 1
6. h program button before plug power hold button until LED is on about 1 sec LEDs turn on alternated push the button again when LED 3 pulse mode or LED 4 hold mode is on Push the button again motor will go up When motor go to top push the button again then motor goes down When motor go to bottom push the button again then motor stops The duration between top and bottom will be record on configuration parameter 2 Z Wave Association Group The HSK 320Z support 13 groups Input port state change can trigger some Z Wave command sending to all devices in a related group See the following table Table 4 Z Wave Association group of HSK 320Z In input mode If any of the 4 ports change it s state the current input state of all 4 ports is represented in bitmap format and send to all devices in group 1 by BASIC_SET Bit 0 is state of port 1 bit 3 is state of port 4 In input mode If any of port 1 to 4 is changed BASIC_SET with be sent to all devices in related group The value of BASIC_SET will be 255 if input port is changed from high to low or the value will be 0 if input port is changed from low to high In the output mode We will turn on off port 1 4 when we receive any BASIC_SET BASIC_REPORT SENSOR_BINARY_REPORT from any nodes listed in these groups In input mode group 6 9 is similar to group 2 to 5 but it will send SENSOR_BINARY_REPORT instead of BASIC_SET In input mode if
7. l be sent every 100ms The current value will not be saved into the NVRAM so that it will become 0 after the power of HSK 320Z is reset In addition the HSK 320Z will receive the multi channel BASIC command which will be translated into RS 485 commands The instance 1 is mapped to 101 and so on Motor Mode When HSK 320Z is in motor mode the output port can be connect to the interface of motor controller The HSK 320Z support three control command up down and stop Port 1 is for up control port 2 is for stop control port 3 is for down control Table 3 Output port function under motor mode please keep it unconnected Z Wave command class COMMAND_CLASS_SWITCH_MULTILEVEL can be used to control motor when HSK 320Z is in motor mode To control motor manually please use SWITCH_MULTILEVEL_START_LEVEL_CHANGE and SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE Use BASIC_SET with desired level can set motor position if calibration is run correctly see the Motor Calibration section There are two type of motor mode supported pulse mode and hold mode Pulse mode turn on related output port only a short period when execute up down stop command most motor controller support this mode Hold mode keeps the related output port turned on when execute up down command and turns off output port when execute stop command homescenario Motor Calibration To calibrate motor control follow the steps 1 2 3 4 5 Pus
8. lease unplug power and plug it again Input Mode The HSK 320Z can be an input extender of HSC 45 To do this associate HSC 45 to group 1 of HSK 320Z The HSK 320Z also can be a 4 port sensor device If any of the 4 input ports is changed it will send Z Wave command to devices in related group The HSK 320Z support 3 types of Z Wave command BASIC_SET SENSOR_BINARY_REPORT and SCENE_ACTIVATION_ SET Please see the chapter Z Wave Association Group for the detail Output Mode When the HSK 320Z is in output mode it support various Z Wave command to turn on off the homescenario four output port e BASIC_SET or SENSOR_BINARY_REPORT Devices associated with group 2 to 5 can control port 1 to 4 Value O turns off port non zero value turns on port If device is not associated with any group the value of BASIC_SET will be regarded as bitmap value of all four ports e SCENE_ACTIVATION_SET command Scene ID 1 turns on port 1 ID 2 turns off port 1 Scene ID 2 turns on port 2 ID 3 turns off port 2 and so on port 3 4 Table 2 Scene ID of SCENE_ACTIVATION_SET MATEO motors Turn on port 4 Turn off port 4 Dimmer mode Under the dimmer mode the input pin of the HSK 320Z can be used to send RS 485 commands to control the 1 10v dimmer module The poort dev is fixed to homescenario For example when we press the 101 the dimmer value will be changed until we release the line The 0 0x66 v wil