Home
        PCIN, Data transfer NC - PC - Service, Support
         Contents
1.  Zparameter    PCIN    Expand PC format file filename with DIR in a main directory startdirectory  More  information in section 3 6 EXPAND PC FORMAT WITH DIR  Example 6 shows  an application     Read in data from NC and expand PC format file filename with DIR in a main  directory startdirectory  This is a combination of the commands DATA_IN PC   FORMAT  section 3 6  and EXPAND PC FORMAT WITH DIR  section 3 6      Generate a PC Format file filename of a complete directory startdirectory  More  information in section 3 6 COLLECT PC FORMAT     Generate a PC Format file filename of a complete directory startdirectory and  transfer it to the NC  This is a combination of the commands COLLECT PC   FORMAT  section 3 6  and DATA_OUT PC FORMAT  section 3 6      Overwrite existing files on NC  Same function as CANCEL in the menu SPECIAL   More information in section 3 5    parameter 0 Overwrite OFF   parameter 1 Overwrite ON    When PCIN is called up  the XON XOFF mode is activated with the following  settings    XON character    11  hex   XOFF character    13  hex    parameter  0 Hardware control with RTS CTS   parameter   1 wait_xon  true send_xon  true   parameter   2 wait_xon  true send_xon  false   parameter   3 wait_xon  false send_xon  true   parameter   4 wait_xon  false send_xon  false     Timeout of serial interface  Same function as TIMEOUT in the menu V24_INI    More information in section 3 1    parameter   0 Monitoring OFF   parameter   1 to 99 Monitoring time between one 
2.  be stored     When a binary file is read in  which is permissible via the V24_INI menu  data  transfer can only be terminated if the time monitoring responds or by depressing the  ESCAPE key     If several main  or sub programs are transferred  PCIN creates a directory with the  name FILENAME DIR  which is displayed when the integrated text editor is called     up     The received data can be viewed on the screen in a special data transfer window  if  the parameter for DISPLAY is set to ON in the SPECIAL menu     3 3 Data transfer from the PC to the NC    DATA_OUT    12    After the DATA_OUT menu item has been selected  the name of the file  whose  data is to be transferred to the NC  is entered and confirmed     If a filename is not entered  or only a partial input with   and or   character  a  description is provided in the operating system documentation   and transfer  acknowledged  an overview is displayed  with the current directories  from which  one or several filenames can be selected with the cursor and the key combination  ALT T     Remark The control sequence ALT T is called up as follows  Press the ALT    key  keep depressed  depress key T and release  release the ALT key        The selected files are then designated with a star symbol at the left  They can be de   selected again using ALT T  The selected files are then transferred in one go     If ETX was activated  either via a parameterized program call  or via the V24_INI  menu  with ETX ON  then transfer of 
3.  files  With PCIN it is possible to create an archive data file with the names of data files  to be transferred  Extension of these data files is  ARV  Overview of the functions   NEW ARCHIV  APPEND ARCHIV  EDIT ARCHIV  TRANSFER ARCHIV  TRANSFER DIRECTORY   NEW ARCHIV Installation of a new archive   1  Input of archive file name  2  An overview is displayed  from which one or several filenames can be selected  with the key combination ALT T   3  Prompting a directory entry in the overview with ENTER changes to that  directory for further selection   4  ENTER Key closes the selection and installs the new archive   18 483 73 403    Siemens AG 1993 All Rights Reserved    SINUMERIK 800 PCIN  BN     08 96    APPEND ARCHIV    EDIT ARCHIV    TRANSFER ARCHIV    TRANSFER  DIRECTORY    PCIN    Append additional data files to an existing archive     1  Select the archive filename  2  Mark the additional datafiles with ALT T  3  Close input with ENTER Key     Edit an archive datafile with the integrated text editor or another preselected  via  EDITOR PATH  editor of the users choice     Select an archive datafile and transfer it to the Numerical Control  All actual  parameters of the serial port are valid     Select a dictionary and transfer it to the Numerical Control  It is possible to specify  a filter  for example  MPF   Then only the main program files with the extension   MPF are selected and transferred  All actual parameters of the serial port are  valid     3 8 Terminating the p
4.  in a particular archive are displayed after the DIRECTORY  PC FORMAT function has been selected  and a filename of an archive file has been  entered or selected     Simultaneously  the DIR COL file is set up in the current directory  which includes  this list  The user may rename the list  The following error message is displayed if  it does not involve an archive file    This file does not have the SINUMERIK PC format        Archives can be expanded in two ways  All files can be transferred into a single  directory  or can be deposited in the PC with the same directory structure as in the  NC     Expanding an archive in only one directory    After the EXPAND PC FORMAT WITHOUT DIR menu item has been selected  all  files  independent of their position in the NC directory structure  are stored in the  current directory  The current directory can be defined via the FILE CHANGE DIR  menu    If the directory was incorrectly selected  all expanded files should remain in the  PCIN catalog  then they can be removed with the DOS command DEL   0    as  their name extension starts with 0  also refer to the SINUMERIK 840C Operators  Guide  Section 6 6     If files with the same name exist in different directories in the NC  it is important to  decide which overwrite mode is selected        Remark Names of programs and other files of the MMC of SINUMERIK  840D FM NC may be as long as 30 characters  which exceeds the 8 characters for  DOS filenames  Therefore the name is shortened to its 
5.  of the disk     Generating PC format files    It is possible to combine several files to form a PC format file after selecting the  menu item COLLECT PC FORMAT    There are two possible ways to do this       FILELIST    KATALOG COMPLETE    First  enter a filename with the extension  COL  This file includes an assignment list   with the elements   Filename in the PC  gt  path filename in the MMC area of  the NC    using this  a PC format file in the NC which can be transferred can be generated   with the name TRANSFER MMC  Individual files must not be copied through an   intermediate buffer  but can be directly transferred to the appropriate sub directory   in the NC     MPF123  gt    MMC 001 USER 005 LOCAL 063 TEIL1 064 MPF123 013           for a part program MPF123  which is to be transferred into the NC  catalog USER LOCAL TEIL1 as MPF123  In this case  the  gt  symbol ensures re   naming  The NC directories are designated with the normal slash     and not with  the backslash      further  each line should be terminated with a semicolon     The last DIR COL file  generated under the menu item DIRECTORY PC FORMAT  can be selected as help  This is already modified when called up for this purpose   so that the  gt  character is located at the beginning of the line and the line is correctly  terminated with a semicolon     After the assignment lines have been entered  you will be asked whether the data is  to be stored and linked with a PC format file  This file  with the desi
6. ETX 03h   Activating Flow Control pein  XO Hardware Control  RTS CTS    XON character   11 hex   XOFF character   13 hex   pein  X  wait_xon  true send_xon  true   pein  X2 wait_xon  true send_xon  false   pein  X3 wait_xon  false send_xon  true   pein  X4 wait_xon  false send_xon  false  Turbomode pein MO ON   pein M I OFF   Timeout pcin Z0 disabled   pein  Zx enabled  x   seconds   Binary file pcin NO OFF   pcin  N7 ON   Overwrite existing files on NC pcin  W0 OFF   pein W  ON   Transfer of complete directory without filter to NC pein  Ddirectory   Transfer of complete directory with filter to NC pcin  Ddirectory filter   Transfer of a file list  All files contained in the file list   pcin  Lfilelist   named filelist are transferred to the NC  Expand PC format file filename with DIR in a main pein  Rfilename  startdirectory  directory startdirectory  Read in data from NC and expand PC format file pein  Sfilename  startdirectory  filename with DIR in a main directory startdirectory  Expand PC format file filename without DIR in a target   pcin Qfilename targetdirectory  directory targetdirectory  Generate a PC Format file filename of a complete pein  Tfilename  startdirectory  directory startdirectory  Generate a PC Format file filename of a complete pein  Ufilename  startdirectory  directory startdirectory and transfer it to the NC                                                                Siemens AG 1993 All Rights Reserved 483 73 403 21  SINUMERIK 800 PCIN  BN     PCI
7. Further  contrary to the basic catalog  this can accomodate as many files  as required  of course limited by the floppy disk capacity         Siemens AG 1993 All Rights Reserved 483 73 403 3  SINUMERIK 800 PCIN  BN     PCIN    Saving against  overwriting    08 96    Catalogs  for example  on a floppy disk in drive A   can be set up on the operating  system level with the MD or MKDIR commands  even while PCIN is running   within the framework of the file functions     The program can be protected against accidental deletion or overwriting using the  MS DOS command ATTRIB  R PCIN EXE     2 3 Setting up on hard disk    Sub directories    Modify  AUTOEXEC BAT    Saving against    It is practical to create a dedicated catalog for PCIN when setting up on the hard  disk  all program floppy disk files can then be copied into this     Sub directories can be set up here for the various data types  Directories can be  set up at the operating system level using the MD or MKDIR commands  even while  PCIN is running  within the framework of the file functions  if  for example   programs  cycles  machine  and setting data or archives for SINUMERIK 840C and  MMC 100 of SINUMERIK 840D FM NC are to be separately stored     This set up for PCIN on the hard disk is only a recommendation  The type of data  administration used is dependent on personal preferences and should not be  unnecessarily restricted by an application program  PCIN allows catalogs to be  created and processed in up to 7 leve
8. IN release 4 is a universal program for data transfer between SINUMERIK  controls and industrial standard PCs via the serial COM1 and COM 2 interfaces   under the MS DOS operating system     In addition to the standard data transfer  and parameterizing functions  PCIN release  4 offers an integrated text editor for processing programs and additional functions  for handling archive files for SINUMERIK 840C and MMC 100 of SINUMERIK  840D FM NC     The interface parameterization can be selected for an actual data transfer and can be  stored permanently on the data medium used     English  French or German can be selected for the user interface of the program   even during operation     The operator control interface can be easily understood  All functions can be  selected via the menu bar with pull down menus and using the cursor keys     With function key F1 a context sensitive help function can be called              I  m          PCIN VERSION 4 41  c  SIEMENS AG 1993 96 COM1 9600   NONE  8 1 RTS                     Select language    V24_INI DATA_IN DATA_OUT FILE SPECIAL PC FORMAT ARCHIV_FILE EXIT                      DISPLAY ON  NC_DIR ON  CANCEL OFF  FILEOPT OFF  SOUND ON  COLOURS  EDITOR PATH  DEFAULT DIRECTORY  LANGUAGE  STATUS OFF  VERSION                Select with     gt   ESC Cancel  ENTER Accept       Fig  1 1 Screen division of the PCIN program release 4   illustrated here when choosing a language     System information with the current data transfer parameters are 
9. N    5    22    Index    A    add CR at end of line  APPEND ARCHIV  archive overview  assignment line  assignment list  AUTOEXEC BAT    B    background color  back up copy  baud   Baud rate   binary file   blank screen    C    cable diagrams   CGA resolution  CHANGE DIR   Change directory   check DSR   CLF  program number  COLLECT PC FORMAT  Command code  COMnumber   configuration commands  configuration file   copy data files   Create directory    D    Data bits   data transfer cable  DATA_IN   DATA_IN PC FORMAT  DATA_OUT   DATA_OUT PC FORMAT  default directory   delete a file   delete CR at end of line  DIR COL   directories   DIRECTORY PC FORMAT  DOS filenames    14  19  16  17  17    14    anv    11    13  13  11  14  17    MO    13  13    11  12  15  12  16  15  13  14    16  16    483 73 403    E    EDIT   edit archive   Editing a file   editor command set   end with M02 or M30  end of text character ETX  ETX code   EXIT with END    08 96    13  19  13  20  10  10   5  19    EXPAND PC FORMAT WITH DIR 16  EXPAND PC FORMAT WITHOUT    DIR  Expanding archives    F    filename  FILENAME DIR  foreground color    G    generating PC format files    I    Initialization   initialize XON XOFF mode  Installation  Interface initialization    L    language selection  Load file into the editor    M    machine data ZERO  MAKE DIR   menu bar   MMC 100 102  MODE COMx  monochrome laptop  monochrome monitor  multiple files    16  18  16    12  14    17    nNwiimn o    14  13    15  20    N
10. SIEMENS    SINUMERIK 800  PCIN   Data transfer NC   PC  Software release 4    User   s Guide Edition 08 96    Manufacturers Documentation    SIEMENS    Introduction    Installation  SINUMERIK 800 Funktion overview  PCIN   Data transfer NC   PC  Software release 4 Application notes  Index    User   s Guide    Manufacturers Documentation    Valid for    Control Software release  SINUMERIK 800    Edition 08 96    SINUMERIK   documentation    Printing history  Brief details of this edition and previous editions are listed below   The status of each edition is shown by the code in the    Remarks    column     Status code in the    Remarks    column     A     New documentation     Unrevised reprint with new Order No   C      Revised edition with new status     If factual changes have been made on the page since the last edition  this is indicated by a new  edition coding in the header on that page     Edition Ident Nr  Remarks   11 94 483 73 403 A  english version   10 95 483 73 403 Cc   08 96 483 73 403 Cc    Other functions not described in this documentation might be executable in the  control  This does not  however  represent an obligation to supply such functions  This publication was produced with WinWord V 6 0 with a new control or when servicing     We have checked that the contents of this document correspond to the hardware    The reproduction  transmission or use of this document or its contents is not and software described  Nonetheless  differences might exist and the
11. The NC SINUMERIK 840D stores programs  cycles      without CR at the end of a line  Some editors  as the internal editor  need a CR   character for editing  This command adds the necessary CRs to the line feeds LF        Remark This option is not necessary for the DOS Editor EDIT COM        Complementary action to ADD CR  For SINUMERIK 840D it is not necessary to  remove all CRs  because they are accepted  but it will save memory space     3 5 Special functions    DISPLAY    NC DIR    CANCEL    FILEOPT    SOUND    COLORS    EDITOR PATH    14    Special configurations of the PCIN data transfer program can be set in this menu   which are stored in the PCIN SYS file when the program is exited  and which are  re activated when called up again  A short  explanatory text to the menu item is  displayed after selection  at the lower edge of the menu     ON Data coming and going to the NC  can be tracked in a data transfer  window on the screen   OFF Data is not displayed during transfer  This setting can be practical for  binary files     Independent of the setting of this parameter  at each data transfer the filename is  displayed to the left  and the display to the right  at the upper edge of the data  transfer window    X bytes sent from Y bytes   Value X indicates the already transferred characters  and Y the complete length of  the file to be transferred     ON When reading in several NC programs  a directory filename  DIR of the  transferred files is set up   OFF No directory f
12. X go to the end of a page  CTRL I Tabulator  go to the next column position which  can be divided by eight  Delete CTRL H or BACKSPACE character to left of cursor  CTRL G or DEL character to right of cursor  CTRL T next word  CTRL Y complete line  CTRL Q CTRL Y up to the end of the line  Insert CTRL M or ENTER insert new line  cursor is positioned in the new  line  CTRL N insert new line  cursor remains in the current line  Other functions CTRL W Scroll the display one line down  CTRL Z Scroll the display one line up  CTRL V Change between OVERWRITING ans INSERT  Terminate editor The editor is terminated using CTRL K CTRL D or ESCAPE  20 483 73 403    Siemens AG 1993 All Rights Reserved    SINUMERIK 800 PCIN  BN     08 96 PCIN    4 3 Configuration commands  an overview    Function Meaning Batch parameter    Output of data file filename pein  Ofilename   Input of data file filename pein  Ifilename   Setting parameters of the serial interface with the pein  PCOMnumber  baudrate  parity  data bits  stop  following assignments  bits   COMnumber   to 2   baudrate 1 to 12   gt  110  150  300  600  1200  2400   4800  9600  19200  38400  57600  115200   parity 1 to 5   gt  space  odd  mark  even  none   data bits 5 to 8  stop bits 1 to 2   Call editor for data file filename pein  Ffilename  Preset for monochrome screen with VGA resolution pein  BPG730   PG730   Preset for monochrome screen with CGA resolution pein  BLCD   Activating ETX pein  EO deactivated   pein  E1 activated with 
13. and 99 seconds for  succeeding characters  Data transfer is aborted when this  time is exceeded        Siemens AG 1993 All Rights Reserved 483 73 403 7    SINUMERIK 800 PCIN  BN     PCIN    Examples     08 96    The following examples are intended to illustrate the use of the configuration  commands when calling up PCIN     Example 1    Calling up PCIN on the PG730 for a light background  black text and flashing  selection bars    PCIN  BPG730     Example 2    Calling up PCIN with the following interface setting  COM2 port  19200 baud   even parity  7 data  and 2 stop bits    PCIN  P2 9 4 7 2    Example 3    Calling up PCIN with an interface setting as in example 2 and calling up the  selected editor and loading the UPROG 002 file    PCIN  P2 9 4 7 2  FUPROG 002    Example 4    Calling up PCIN with transfer of all data files of directory MACHINE in drive C of  the PC to the NC    PCIN  Dc  MACHINE   Example 5    Calling up PCIN with transfer of all main programs in directory MACHINE in  drive C of the PC to the NC    PCIN  Dc  MACHINE   MPF    Example 6   Calling up PCIN and expanding the data files from ARCHIVE  DAT corresponding  to the original directory structure into the directory treasure on drive D   PCIN  RARCHIVE DAT d  treasure  QO    483 73 403    Siemens AG 1993 All Rights Reserved  SINUMERIK 800 PCIN  BN     08 96    8 96 PIN    3 Function overview    The individual PCIN functions are subdivided into 8 function groups  corresponding  to the logical procedure for 
14. ave to be set here  which are offered in a submenu    XON XOFF ON XON XOFF operation enabled  OFF no XON XOFF operation    XON Character Character to start a transmission  Works only for  enabled XON XOFF operation  Standard   character for DC1  Device Control 1  XON   is  11  HEX   This is the default value     XOFF Character Character to stop a transmission  Works only for  enabled XON XOFF operation  Standard   character for DC3  Device Control 3  XOFF   is  13  HEX   This is the default value      DONT  WAIT FOR XON WAIT FOR XON  When reading in the program waits for an XON  from the NC   DONT WAIT FOR XON  XON character has no effect      DONT  SEND XON SEND XON  At data output  XON is sent  until the connected  partner responds with XON   DONT SEND XON  No XON is sent     END_W_M30 ON When during reading in a string M02 or M30 is detected  communication  will stop  This is only valid for the setting BINFILE OFF   OFF M02 and M30 have no effect     ETX ON Atthe end of DATA_OUT to the NC an additional end of text character  is transmitted   Detecting an ETX character during DATA_IN from the NC stops the  transmission   OFF No ETX character is transmitted or detected     Switching from OFF to ON opens an additional box for input of an ETX character  in HEX format        Remark This function is not recommended for binary files  They may contain  ETX characters in their data        TIMEOUT VALUE 0  Monitoring is disabled     VALUE 1 99  A monitoring time between one and 99 s
15. d after the PC   FORMAT menu has been selected     DATA_IN PC FORMAT   DATA_OUT PC FORMAT  DIRECTORY PC FORMAT   EXPAND PC FORMAT WITHOUT DIR  EXPAND PC FORMAT WITH DIR  COLLECT PC FORMAT     Transfer of archives from the NC to the PC    After the menu item DATA_IN PC FORMAT has been selected  the filename  in  which the archive is to be stored  must first be entered  and the filename transfer  acknowledged  If a filename was not entered  or only a partial entry with   and or    and the transfer was confirmed  an overview of the current directories is displayed   from which a filename can be selected using the cursor  PCIN then waits for the  archive to be transferred        Siemens AG 1993 All Rights Reserved 483 73 403 15    SINUMERIK 800 PCIN  BN     PCIN    DATA_OUT  PC FORMAT    DIRECTORY  PC FORMAT    Expanding archives    EXPAND  PC FORMAT  WITHOUT DIR    EXPAND PC   FORMAT WITH DIR    16    08 96    Transfer of archives from the PC to the NC    After the menu item DATA_OUT PC FORMAT has been selected  the  TRANSFER MMC filename is displayed as presetting  which can be replaced by a  different filename  If a filename is not entered  or only a partial entry with   and or     and the transfer was confirmed  an overview of the current catalog is displayed   from which a different directory can be selected with the cursor  or a filename with  ENTER  Data transfer starts after a transferrable file has been selected     Provides an archive overview    A list of all the files
16. data transfer  These groups are quickly reached using  the pull down menus     Initialization of the serial interface   Data transfer from the numerical control to the PC  Data transfer from the PC to the numerical control  Processing and administering files   Special functions   Transfer and handling of data files in PC format  Transfer and handling of archives   End of program    The menus are selected via the ENTER key  individual menu items are selected  using the cursor control keys T and    UP and DOWN   Parameters can be  modified using the cursor control keys  lt     and     gt   RIGHT and LEFT   If several  parameters are available for selection  a sub menu is displayed  Menu selection can  be aborted using the ESCAPE key     3 1 Initializing the serial interface    The parameters of the computer serial interface  on which PCN runs  can be set  using the V24_INI menu     COM NUMBER 1 or 2  These are the standard serial ports  COM1 and COM2    BAUD RATE 110  150  300  600  1200  2400  4800  9600  19200  38400  57600 or 115200  When selecting the baud rate  the restrictions imposed by the computer or the  interface card used should be observed  these are specified in the Instruction  Manual    PARITY SPACE  0   ODD  uneven parity   MARK  1   EVEN  even parity  or NONE  no  parity    STOP BITS 1 or 2 stop bits   DATA BITS 5  6  7 or 8 data bits      Siemens AG 1993 All Rights Reserved 483 73 403 9    SINUMERIK 800 PCIN  BN     PCIN 08 96    XON XOFF SETUP 5 parameters h
17. directory is displayed after it has been  selected with ENTER  Select the required directory or drive using the cursor keys   and transfer with function key F2     Either English  French or German user screens can be selected in a sub menu   However  the help text is only in German     ON Display status of control lines CTS RTS and DTR DSR of the active  RS 232 port  OFF No such display     Outputs the release number of the PCIN program     3 6 Special functions for PC Format    DATA_IN  PC FORMAT    Functions are provided in the PC FORMAT menu  which are provided to handle  archived files in the format for SINUMERIK 840C PC and MMC 100 102 of  SINUMERIK 840D FM NC     SINUMERIK 840C and MMC 100 102 of SINUMERIK 840D FM NC provide the  possibility of storing directories and files in archive lists  to support data back up   i e  a list of all important files and directories can be stored under names defined by  the user  and this in turn can be output  en block  to an external device  Archive list  handling at the NC is described in more detail in Section 6 SERVICES of the  SINUMERIK 840C and 840D FM NC Operators Guide     The PC format can be selected as output format for archive lists  All available data  can be output in the PC format  PC format data includes all of the information  regarding from which path or directory  the data was read out  When reading in   they are re loaded in the same fashion     A selection field with special functions for the PC format is displaye
18. econds can be set  here  which defines the maximum time between individual  characters  when reading data into the PC  Data transfer is  aborted when this time is exceeded     10 483 73 403    Siemens AG 1993 All Rights Reserved  SINUMERIK 800 PCIN  BN     08 96    PCIN          BIN FILE ON  All received characters are stored  i e   there is no delay until a    character is received  indicating the start of valid data  Read in can only  be aborted using the ESCAPE key  The same is true when sending data to  the NC    OFF  ASCII files are accepted    Remark If the DISPLAY parameter is set to ON in the SPECIAL menu  screen  display switched in   then the internal loudspeaker sounds  when binary files are  being transferred  dependent on the transferred data  even if the parameter for  SOUND is at OFF in the SPECIAL menu  If this is not desired  set DISPLAY to  OFF  Data transfer can be tracked by the characters which are displayed at the  upper edge of the  now empty  data transfer window    TURBOMODE ON  Higher data rate by means of    Blocktransfer of data    Suppressed screen output    Reduced keyboard scanning   OFF  Normal operation   DONT  CHECK DSR CHECK  Signal for data set ready DSR is effective  A missing signal  stops communicatioon  DONT CHECK  DSR has no effect    NC SEA 850 880 This is a help display  which shows the SINUMERIK 850 880 settings for V 24  interfaces  The setting data of other interfaces is displayed using the RIGHT LEFT  cursor keys    WIRELAYOUT Th
19. first characters    The original filenames are stored in a data file   COL with full length  Therefore  they are available for retransmission     Example   The data file with the name  N_MY_FIRST_MATNPROGRAM_MPF  is shortened to  MY_FIRST MPF   The string _N_ and _MPF don   t appear at the user interface  they are part of the file  management           Expand with transfer of the directory structure   Files in the archive can be stored in the same directory structure as in the NC by  selecting the function EXPAND PC FORMAT WITH DIR  It should be noted  that  the directory structure in the NC has a specific depth  The part programs  e g  in the  4th directory level  are stored  in Fig  3 1  In order not to exceed the maximum DOS  64 character path string  it is not permissible that this archive is unpacked  for  example  in a directory at the 6th level     483 73 403    Siemens AG 1993 All Rights Reserved  SINUMERIK 800 PCIN  BN     08 96    COLLECT  PC FORMAT    Example of an    assignment line     Transfer                                              PCIN  MMC 001     MMC  001 USER 005    2a  MMC 001 USER 005 LOCAL 063      MMC 001 USER 005 LOCAL 063   MPF1 013      MMC 001 USER 005 LOCAL 063   MPF2 013          Fig  3 1 Example of part program in 4th level    Prior to expansion it is necessary to specify a main directory for the following  directory structure  With this method it is possible to store various data files for  example from different NCs in separate directories
20. gnation  TRANSFER MMC  can then be transferred to the control using the function DATA   OUT PC FORMAT in the PC FORMAT menu     Programs and other files can only be transferred in the directories which are  generally accessible to the user for NC operator control  If an attempt is made to       Siemens AG 1993 All Rights Reserved 483 73 403 17    SINUMERIK 800 PCIN  BN        PCIN    COLLECT  PC FORMAT FROM  FILELIST    08 96    transfer data into the  Siemens  branch  this is rejected with the system error  message  106 or  154     This function collects data files  which are expanded with EXPAND PC FORMAT  WITHOUT DIR  It is possible to select an existing data file   COL  which is  modified in the following manner    Each line begins with a  gt  Symbol  followed by the file name and terminated by a  semicolon  All generated list data files have the extension  COL              Example  Direct storage of the user memory module ASM of the SINUMERIK 840C in  english language  The list ASM COL contains the following line   ASM AIH  gt    MMC  001 USERS  005 NCK 008 ENGLISH 008 ASM 018   COLLECT This function collects data files  which are expanded with  PC FORMAT FROM EXPAND PC FORMAT WITH DIR   KATALOG In a user defined main directory the program generates a data file  COMPLETE TRANSFER MMC  which contains all files  even from the subdirectories   The INFO file   MMC 01 TEMP 003   DTSINF 001  contains the file names of the selected data files   3 7 Special functions for archive
21. is is a help display  which shows the wiring of the appropriate data transfer  cable    The schematically displayed cable diagrams show cables for SINUMERIK 800   25 pin submin D connector  and for SINUMERIK 840D FM NC  9 pin submin D  connector    The cable illustrated on the left  corresponds to types  6FC9 344   4RO  whose connector is equipped with pins on the PC side  They are therefore suitable  for the COM  connection for the PG 730 and PG 750 programming units   The cable illustrated in the center corresponds to types  6FC9 344  4TO  whose connector is equipped with sockets on the PC side  They are suitable for  standard PCs with 9 pin COM connection   The cable illustrated on the right corresponds to types  6FX2 002 1AA01 0     Siemens AG 1993 All Rights Reserved 483 73 403 11    SINUMERIK 800 PCIN  BN     PCIN    08 96    3 2 Data transfer from the NC to the PC    DATA_IN    Binary files    Multiple files    After the DATA_IN menu item has been selected  the file name  into which the  read in data is to be stored  is entered  and the correct filename confirmed     Data transfer is then automatically started and runs until it is terminated with the  reception of 40 HEX00 characters  the ETX character  the character sequence  M02 M30  the time monitoring responds  or the user terminates it himself with the  ESCAPE key  In the latter case  it cannot be guaranteed that data transfer was  complete  and therefore a prompt asks whether the data which was transferred is to 
22. le list named filelist are  transferred to the NC     Setup Turbomode   parameter  0 OFF  Normal operation  parameter 1 ON  Higher data rate by means of    Blocktransfer of data    Suppressed screen output    Reduced keyboard scanning     Switch ON OFF Binary file    parameter 0 OFF  ASCTII files are accepted   parameter 1 ON  For transfer of binary files  Abort of transfer only via  ESCAPE key or activated ETX character     The file with the name filename  is output via the serial interface     This command sets the interface parameters with the following assignment when  PCIN is called up  whereby the parameters are separated by commas     1 for COM1   2 for COM2   1 for 110 baud 7 for 4800 baud   2 for 150 baud 8 for 9600 baud   3 for 300 baud 9 for 19200 baud  4 for 600 baud 10 for 38400 baud  5 for 1200 baud 11 for 57600 baud  6 for 2400 baud 12 for 115200 baud  1 for SPACE   0    2 for ODD   3 for MARK   1    4 for EVEN   5 for NONE    5  6  7  8 are possible  1  2 are possible    The characteristic values of the PC used should be observed when setting the baud  rate  especially for higher data transmission rates     Expand PC format file filename without DIR in a target directory targetdirectory   More information in section 3 6 EXPAND PC FORMAT WITHOUT DIR     483 73 403    Siemens AG 1993 All Rights Reserved  SINUMERIK 800 PCIN  BN     08 96     Sfilename   Startdirectory     Tfilename   Startdirectory   Ufilename     startdirectory     W parameter     Xparameter    
23. located in the  uppermost line  The menu bar is located beneath this with the pull down menus to  select individual functions via the ENTER key  Depending on the particular  situation  a working  or transfer window is displayed  the actual path and file  information appears at its upper edge  The displayed dialog panel is provided for  operator prompting        Siemens AG 1993 All Rights Reserved 483 73 403 1    SINUMERIK 800 PCIN  BN        PCIN 08 96    To use the program  only basic knowledge is required regarding the computer and  the operating system  If questions arise  refer to the computer User Manual and the  operating system documentation     1 2 Version overview    Version 4 4 Note for PCIN 4 4  The special functions for PC format    EXPAND PC FORMAT WITHOUT DIR    EXPAND PC FORMAT WITH DIR    COLLECT PC FORMAT  are now useful for the MMC 102 of the SINUMERIK 840D FM NC     The functions are suitable for usual archives  MMCARC   and for Start Up archives  MMCIBN      The type of numerical control or the type of MMC are detected automatically     2 48373403    Siemens AG 1993 All Rights Reserved  SINUMERIK 800 PCIN  BN     08 96 PCIN    2 Installation    The program floppy disk provided should be write protected and a back up  working copy made  The original floppy disk should be stored in a safe place and  only the working copy should be used     The following files are stored on the program floppy disk     PCIN EXE Program file for PCIN release 4  PCINGERM HLP Hel
24. ls  For example  it is also possible to keep the  PCIN program on floppy disk  and only store the data on the hard disk     If PCIN is to be called up from a different directory or drive  then the path  instruction should be entered into the AUTOEXEC BAT file     The program can be protected against accidental deletion or overwriting using the    overwriting MS DOS command ATTRIB  R PCIN EXE   2 4 Configuration  Certain parameters are pre set for the PCIN program when supplied   e COMI  9600 baud  8 data bits  1 stop bit  no parity   e Dark blue background  yellow foreground and red bars  Monochrome These colors refer to colors for a color monitor  When a monochrome monitor is  monitor used it is possible that these colors are displayed in identical grey tones  In this  case  the PCIN program can be immediately called up with parameters for screen  display  This is described in Section 2 5   The serial interface can be modified via the V 24_INI menu  Section 3 1  and other  characteristic values such as screen display via the SPECIAL menu  Section 3 5    Data file for Such a setting can be stored in a PCIN SYS configuration file  which can be    configuration    automatically generated when the PCIN program is exited     483 73 403    Siemens AG 1993 All Rights Reserved  SINUMERIK 800 PCIN  BN     08 96    PCIN    2 5 Calling up the program    Calling up with  parameters    Configuration    Calling up the program is simply typing PCIN from the DOS command line   When calling 
25. n    12       Siemens AG 1993 All Rights Reserved  SINUMERIK 800 PCIN  BN     08 96    N    Names of programs  NC DIR   network software  NEW ARCHIV    O    Output file    P    Parity   path of ext  editor  PC FORMAT  PCIN EXE  PCIN SYS   PG 730   PRINT   program floppy disk  pull down menus    R    release number    S    SAVE CONFIGURATION Y N       Saving against overwriting  Screen pre setting  selection bar color       Siemens AG 1993 All Rights Reserved 483 73 403    SINUMERIK 800 PCIN  BN     16  14  20  18    14  15    em  ePWW MW Ww    15    A    14    send XON   setting data  SINUMERIK 840C  SINUMERIK 840D FM NC  sound   status of control lines  Stop bits   Store data in the file  Sub directories  system error message  System information  System requirements    T    terminate with ALT X  timeout   transfer archive  transfer directory  transfer of archives  transfer window  TRANSFER MMC  turbo mode    W    wait for XON  working copy    X    XON XOFF SETUP  XON XOFF operation    PCIN    19  10  19  19  15  1  14    11    10    10  10    23    
26. nochrome laptop LC displays with CGA resolution  This call up  parameter is recommended if the screen is blank after PCIN has been called up  without parameters     BPG730 Pre setting for monochrome laptop LC displays with VGA resolution  such as the  PG 730 SIMATIC programmer  This setting provides black text on a light  background with flashing bars  The setting can be modified in the SPECIAL menu   and can be stored when the program is exited  so that it only has to be specified  when first called up     Ddirectory Transfer of complete directory without filter to NC  see example 4     Ddirectory filter Transfer of data files  defined by filter  to NC  see example 5        Siemens AG 1993 All Rights Reserved 483 73 403 5    SINUMERIK 800 PCIN  BN     PCIN     Eparameter     F filename    Nfilename     Lfilelist     Mparameter     Nparameter     Ofilename     PCOMnumber  baud  rate  parity  data  bits  stop bits    COMnumber     Baud rate     Parity     Data bits     Stop bits      Qfilename   targetdirectory     Rfilename   startdirectory    08 96    The command activates deactivates the ETX code with ETX 03  hexadecimal    parameter  0 ETX not active  parameter  1 ETX active     When PCIN is called up  the pre set editor is called  and the file with the name  filename is loaded  The cursor is located at the first file character     Data  read in via the serial interface  is stored in the file with the name filename     Transfer of a file list  All files contained in the fi
27. og by making an  extension to this designation  or he can set up any particular directory     PRINT Prints out a selected file via the first parallel interface LPT1    An entry field  preset with the current catalog  appears after selecting PRINT using  the ENTER key  the required file name can be specified  With a partial name  e g   using      all appropriate files are displayed in a selection window  The file to be  printed out is selected using ALT T  and is sent to the first parallel interface LPT1   with ENTER     No printer control commands are output  Only a line break is inserted after a  maximum of 80 characters  Machine data is output in four columns     DELETE Deletes one or several files in the selected directory   An entry field  preset with the last processed file  is displayed after selecting  DELETE using the ENTER key  This can be replaced by a new filename  This is  then deleted with ENTER   When a partial name is entered e g  using      all appropriate files are displayed in  a selection window  All of the files to be deleted are selected with ALT T  and  deleted using ENTER  Before each individual file is finally deleted  you are asked  to confirm that you really wish to delete that file     COPY Copy data files  First input of filename of source file  then input of the destination  file name  Copy to file          Siemens AG 1993 All Rights Reserved 483 73 403 13  SINUMERIK 800 PCIN  BN     PCIN    ADD CR    DELETE CR    08 96     CR   carriage return   
28. one or more files is terminated with the ETX  character     483 73 403    Siemens AG 1993 All Rights Reserved  SINUMERIK 800 PCIN  BN     08 96 PCIN    3 4 File functions    The following functions are provided in the FILE menu     EDIT Editing a file  CHANGE DIR Change directory  MAKE DIR Create directory  PRINT Printing a file  DELETE Delete a file  COPY Copy data files  ADD CR Add CR  carriage return  at end of line  DELETE CR Delete CR  carriage return  at end of line   EDIT Processing a file with the integrated text editor or another text editor  whose path    and complete name can be set up in the SPECIAL menu     Internal text editor The integrated text editor is selected using EDIT  and operates with a command set   which is essentially compatible to WORDSTAR  word processing program   An  overview of the control sequences is given in section 4 2     CHANGE DIR After CHANGE DIR has been selecting using the ENTER key  an overview of the  directories and drives which can be reached from the current directory  is  displayed  Go to the required directory using the cursor keys  and change into the  selected directory using the ENTER key     This selected directory  which is located in the header line of the selection field   can be transferred with function key F2  and is valid  e g  for editing a file as  presetting     MAKE DIR An entry field appears after selecting MAKE DIR with the ENTER key  in which  the actual directory is listed  The user can define a new sub catal
29. or several transferred files     ON Ifa program is to be transferred to the NC  whose name already exists in  the NC  then the NC file is automatically deleted before data transmission  by initiating CLF  program number  only for SINUMERIK 805  810   820  850 and 880     OFF The NC file with the same name is not overwritten     ON When reading in machine data  those with zero contents are not stored   OFF Machine data is stored independent of their contents     ON The PC emits a brief acoustic signal at the end of data transfer   OFF No acoustic signal is emitted at the end of data transfer     A sub menu is displayed here  where background  foreground as well as selection  bar colors can be selected using the RIGHT LEFT cursor keys  In addition to  steady state colors for the selection bars  flashing and underlined displays are  possible  which is especially recommended for monochrome monitors     If a different text editor is used other than the integrated text editor  then the  complete path and name with name extension  for executable programs  COM or   EXE  of the other text editor should be entered in the input field  Example of an  editor EDIT COM in directory DOS on the hard disk D  D  DOS EDIT COM     483 73 403    Siemens AG 1993 All Rights Reserved  SINUMERIK 800 PCIN  BN     08 96    DEFAULT  DIRECTORY    LANGUAGE    STATUS    VERSION    PCIN    A directory can be selected here after program start  An overview of directories  which can be reached from the current 
30. p text in German  README   TXT Note for PCIN 4 4   2 1 System requirements    The PCIN program  release 4 can be installed on any computer  which has the  following specifications     Industrial standard PC or AT   Standard graphics card  Hercules  CGA  EGA  VGA    3 5  floppy disk drive  1 44 MB    Approx  200 Kbyte free memory for program   memory for a file to be  processed   e Hard disk    Depending on the particular application  the program can generate the following    files    PCIN SYS File  in which the PCIN configuration is stored    DIR COL Collect file  which can be used to assemble the file in the PC  format and which contains the directory of the last expanded  file in the PC format      COL Collect file for the user to assemble the file in the PC format    TRANSFER MMC Collect file  which contains the linked files in the PC  format  and which can be transferred to the SINUMERIK  840C control or the MMC 100 of SINUMERIK 840D FM     NC     ARV Archive file in PCIN  2 2 Installation on floppy disk  Setting up on The working floppy disk can be immediately used with the PCIN program  PCIN  floppy disk supports the hierarchic file structure  catalogs or directories  from MS DOS  also  on floppy disk   Directories It is recommended that PCIN program files are left in the basic catalog  and that    dedicated catalogs are created for the various data types  such as programs  cycles   machine data or archives  The main advantage is that the data can be better  organized  
31. refore we  permitted without express written authority  Offenders will be liable for damages  cannot guarantee that they are completely identical  The information contained in  All rights  including rights created by patent grant or registration of a utility model or this document is  however  reviewed regularly and any necessary changes will  design  are reserved  be included in the next edition  We welcome suggestions for improvement       Siemens AG 1994  All rights reserved  Subject to change without prior notice    Ident Nr  483 73 403 Siemens Aktiengesellschaft     Printed in the Federal Republic of Germany    08 96 PCIN    1 Introduction 1  1 1 Short description           1 2 Version overview 2  2 Installation 3  2 1 System requirements 3  2 2 Installation on floppy disk 3  2 3 Setting up on hard disk 4  2 4 Configuration 4  2 5 Calling up the program 5  3 Function overview 9  3 1 Initializing the serial interface 9  3 2 Data transfer from the NC to the PC 12  3 3 Data transfer from the PC to the NC 12  3 4 File functions 13  3 5 Special functions 14  3 6 Special functions for PC Format 15  3 7 Special functions for archive files 18  3 8 Terminating the program 19  4 Application information 20  4 1 Interfaces and networking 20  4 2 Control sequences of internal editor 20  4 3 Configuration commands  an overview 21  5 Index 22       Siemens AG 1993 All Rights Reserved 483 73 403 i  SINUMERIK 800 PCIN  BN     08 96    PCIN    1 Introduction    1 1 Short description    PC
32. rogram    The program can be exited in two ways     1  Terminate with ALT X from the main menu without any request  2  EXIT with the END menu   and the requests    ARE YOU SURE Y N     SAVE CONFIGURATION Y N       The configuration is saved in a new or existing datafile PCIN SYS  It contains  parameters  which are valid for the next call of PCIN        Siemens AG 1993 All Rights Reserved 483 73 403 19    SINUMERIK 800 PCIN  BN     PCIN 08 96    4 Application information    4 1 Interfaces and networking    DOS command Bypassing the serial interface  or parameterizing with the DOS command MODE  MODE COMx COM  can result in erroneous operation at read in  If the following error message  is displayed  CTS RTS not wired  then the MODE command should be removed and the computer re booted     Network driver If the PC has a network card  and the above error message is displayed when  reading in data  then the network software should not be called up     4 2 Control sequences of internal editor  Control sequences The integrated text editor operates with a command set  which is essentially  of internal editor compatible to WORDSTAR   Cursor control CTRL S one character to the left  CTRL D one character to the right  CTRL E one line back  CTRL X one line forward  CTRL A one word back  CTRL F one word forward  CTRL R one page back  CTRL C one page forward  CTRL Q CTRL S go to the start of a line  CTRL Q CTRL D go to the end of a line  CTRL Q CTRL E go to the start of a page  CTRL Q CTRL 
33. up the PCIN program  it is possible to specify configuration  commands with parameters  which are used to adapt to specific hardware    environments  or allow PCIN to be flexibly called up in BATCH files     The configuration commands are separated from program names by a blank  They    commands start with a slash      followed by the command code and the parameters associated  with the particular command    You may generally combine all command codes  They are treated from left to right  in the command line  Between command code  e g   O  and parameter ore ASCII   string no blank is allowed  If there exists a data file PCIN SYS  its parameters are  loaded first  These parameters may be overwritten by the following batch  parameters   PCIN  command code parameter  Command code Action   B Screen pre setting   D Transfer of complete directory   E ETX code   F Load file into the editor   I Store data in the file   L Transfer of a file list   M Preset Turbomode   N Switch ON OFF Binary file   O Output file   P Interface initialization   Q Expand PC format file without DIR   R Expand PC format file with DIR   S Read in data from NC and expand PC format file with DIR   T Generate a PC format file of a complete directory   U Generate a PC format file of a complete directory and   transfer it to the NC   W Preset overwrite mode   X Initialize XON XOFF mode   Z Preset timeout mode    Parameter Dependent on the command   The individual configuration commands     BLCD Pre setting for mo
    