Home

Allen-Bradley Bulletin 2362

image

Contents

1. 1336 PLUS Variable Frequency 1336 PLUSTM II 1336 FORCE Vector Control 1336 IMPACT Product Selection 2 3 Drive Unit Options Table 2 B Drive Unit Options Options Available to All Units Option Option 6006 Description Control Power 6P Individual 115V AC secondary control power transformer supplied per drive unit Includes primary fusing Source 6TB 115V AC control power factory wired from 115V AC control bus to drive unit requires control bus 6SC 115V AC control power supplied by customer 230V AC 380V AC 512V DC 575V AC 775V DC Input Voltage gt 310V DC 460V AC 620V DC Auxiliary Contact Frame Size gt ABC A B C D E FGH A B C D E F G H for 98 1 normally open Y option avail Y Y Y Disconnect9 99 1 normally closed Y option avail Y Y Y 989 1 normally open 1 normally closed Y option Y Y avail Wire Label 14WLBL Brady Datab wire labels Upgrade Option T Handles 111 T handles on doors and 3 vertical wireway present in MCC sections containing frame A B amp C drive units Door Mounted 1ES Hardwired interface stop pushbutton for drive disable function Devices 4EA Control power on pilot light 4EB Drive at speed pilot light 4ER Drive run pilot light 4EW Drive faulted pilot light Miscellaneous J11 Audio phone jack J12 115V AC 15A duplex receptacle Unit Door M3EW Phenol
2. 1336 PLUS Variable Frequency 1336 PLUSTM II 1336 FORCE Vector Control 1336 IMPACT Product Selection 2 5 Enclosure Options Available to All Units Option Description Sane Input Voltage gt 230V AC 380 460V AC 575VAC 310VDC 512V 620V DC 775V DC Depth Frame Size gt 5 5 w w co jer m x je T I A NX J Ci t Sl t gt a gt gt lt C lt C lt lt C lt C a 2 lt C Q o 15 deep MCC Y option avail Y Y Y Y Y Y 20 deep MCC Y option avail Y Y Y Y IY Y Y Y Y Y 25 deep MCC Y option avail Y Y Y Y 1 5 Inch High Required R or Optional O 0 0 0 5 0 0 0 0 RI 0 0 Base Channels 7 Horizontal Power Input Voltage gt 230V AC 310V DC Bus 6 18 14 15 380V AC 512V DC 1 460V AC 620V DC 575V AC 775V DC 800A Y option avail Y Y 1200A Y option avail Y 1600A Y option avail Y Y 2000A Y option avail Y 3000A Y option avail Y Y Orong Pus PE PE TE bus for unit with horizontal power bus rated up to 2000A TE PE TE bus for unit with horizontal power bus rated up to 3000A 115V AC Control 90A control bus Bus 10 16 Top Hatt 12 high top hat for extra entry cable bending radius 1 You must select 1 option from this group 2 All drives mounted in the same MCC vertical section must have option 111 if any one drive unit has option 111 3 Yo
3. Features and ModificationS X KK kK KK KK KK KK KK KK KK KK KK KK KK KK KK kk 3 1 Busbar Splice Kits Understanding Busbar Splice Catalog Numbers KK KK KK KK KK KK KK KK KK 4 1 Determining Splice Kit Catalog Numbers WW KK KK KK KK KK KK KK KK KK KK KH 4 1 Splice Kit Catalog Numbers 2220222222 KK KK KK KK KK KK KK KK KK KK K 4 1 Power Bus Splice Kit Catalog Numbers WA KK KK KK KK KK KK KK KK KK KK KK 4 1 Control Bus Splice Kit Catalog Numbers La kK KK KK KK KK KK KK KK KK KK K eee 4 2 PE TE Bus Splice Kit Catalog Numbers 2220202222 KK KK KK KK KK KK KH 4 2 ii Table of Contents About This Publication General Product Description Preface Introduction Motor Control Centers offer a convenient design for the configuration of AC drive lineups When configured in conjunction with a Bulletin 2100 main incoming structure the CENTERLINE thru bus solution eliminates the challenge of low voltage power distribution for drives We designed this publication to help you configure AC drive equipment within Bulletin 2100 CENTERLINE Motor Control Center MCC sections The selection tables in this publication will help you specify the necessary sections and units Important When using this publication please be sure to read all footnotes Footnotes are used throughout this publication to advise you of configuration and limitation of structures units and options For PowerFlex drive units
4. Bulletin 2362 Units Bulletin 2362HA 125HP Roll Out Unit Allen Bradley Bulletin 2362 Digital AC Drives in CENTERLINEO Motor Control Centers 1336 PLUS Variable Frequency 1336 PLUS II 1336 FORCE Vector Control 1336 IMPACT PowerFlex 700 PowerFlex 700S Selection Guide Rockwell Automation Table of Contents Preface Chapter 1 Chapter 2 Chapter 3 Chapter 4 Introduction About This Publication nern sten ana p 1 General Product Description L kk KK KK KK KK KK KK KK KK KK KK KK KK KK KK K p 1 Plug In Drive Units ants nies wna ana Ra den wi dw a p 2 Frame Mounted p 2 Roll Out Drive Units sk dpi nl N alia berl ye Q ada kena QI Zu n kan at p 3 UL Certification 2 5 32 er oS re Ba ER p 3 Documentation A35 Ll IAA SSA Ae A een Dee are p 3 PowerFlex 700 and 700S Product Selection Catalog Number Explanation 0 0 KK KK KK KK KK KK KK ee KK KK KK KK K 1 1 Frame Selection ors xe ta AE ae ai 1 2 Drive Unit Options 43 2 k en ri Gee eh a 1 3 1336 PLUSTM Variable Frequency 1336 PLUS II 1336 FORCE Vector Control 1336 IM PACT Product Selection Catalog Number Explanation 222222 KK KK KK KK KK KK KK KK KK KK KK KK KK KK K 2 1 Frame Sel c tion ira tte d san diket kl ma A A is 2 2 Drive Unit Options gt reii ii eae a BE AW a Kan ees 2 3 Motor Control Center Vertical Sections
5. 1336 PLUS II 1336 FORCE Vector Control 1336 IMPACT Product Selection Frame Selection The following table is used to determine the frame size required based on the desired Drive Type Input Voltage and Horsepower Table 2 A 1336 Frame Selection 1336 Frame Sizes Drive A B 0 D E F G H Type 1 5 SF 2 5 SF 3 5 SF 6 0 SF 6 0 SF 6 0 SF 6 0 SF 6 0 SF Code Input Voltage 20 Wide 20 Wide 20 Wide 20 Wide 25 Wide 35 Wide 35 Wide 35 Wide E 230V AC 05 50HP 7 5 15HP 10 30HP NA NA NA NA NA 9 380 460V AC 0 5 5 00 7 5 30HP 40 50 60 125 HP 150 250 HP 300 400 HP 450 600 HP NA 575V AC 1 3 HP 7 5 20HP 25 60HP 75 125 HP 150 300 HP 350 400 HP 450 650 HP NA SiG 310V DC 05 50HP 7 5 15HP 10 30HP NA NA NA NA NA 512 620VDC 0 5 5 0HP 7 5 30HP 40 50HP 60 125 HP 150 250 HP 300 400 HP 450 600 HP NA 775V DC 1 3 HP 7 5 20HP 25 60HP 75 125 HP 150 300 HP 350 400 HP 450 650 HP NA F 230V AC NA 1 3 7 5 15HP 20 30 HP NA NA NA NA NA 5 380 460V AC NA 1 3 7 5 30 HP 40 50 HP 60 125 HP 150 250 HP 1300 400 HP 450 600 HP NA S 575V AC NA 1 3 7 5 20HP 25 60HP 75 125 HP 150 300 HP 350 400 HP 450 650 HP NA 5H 310V DC NA 1 3 7 5 15HP 20 30 HP NA NA NA NA NA 0 512 620V DC NA 1 3 7 5 30 HP 40 50 HP 60 125 HP 150 250
6. 60 NA NA 380V AC ND kW 10 75 11 15 5 22 37 45 55 75 90 132 132 160 Future HD kW 0 55 7 5 11 15 8 5 30 37 45 55 75 110 110 132 Future 460VAC ND HP 5 5 20 25 30 50 60 75 100 125 150 1200 250 Future HD HP 10 33 10 15 20 25 40 50 60 75 75 125 150 200 Future 575V AC ND HP 0 5 15 20 25 30 50 60 75 100 125 150 150 200 Future HD HP 10 33 10 15 20 25 40 50 60 75 100 125 150 Future T 310VDC ND HP 0 5 7 5 10 15 20 25 30 40 50 60 75 NA NA HD HP 10 33 5 7 5 10 15 20 25 30 40 50 60 NA NA 512VDC ND HP_ 0 75 11 15 18 5 22 37 45 55 75 90 132 132 160 Future HD HP 0 55 7 5 11 15 8 5 30 37 45 55 75 0 110 132 Future 620V DC ND HP 0 5 15 20 25 30 50 60 75 100 125 150 200 250 Future HD HP 10 33 10 15 20 25 40 50 60 75 100 125 150 200 Future 775VDC ND HP 05 15 20 25 30 50 60 75 100 125 150 150 200 Future HD HP 10 33 0 15 20 25 40 50 60 75 100 125 150 Future UT Frame 10 is a 25 inch deep flush back enclosure PowerFlex 700 and 700S Product Selection 1 3 Drive Unit Options Table 1 B PowerFlex 700 and 700S Drives Options Available to All Units Option Option Code Description Control Power 6P Individual 115V AC secondary control power transformer supplied per drive unit Includes primary fusing Source
7. 2 3 4 5 6 Type Duty 2 0 SF 2 0 SF 2 0 SF 3 0 SF 6 0 SF 6 0 SF 6 0 SF Code Input Voltage Rating 20 Wide 20 Wide 20 Wide 20 Wide 20 Wide 20 Wide 25 Wide Q 230V AC ND HP 0 5 1 2 75 10 15 20 25 30 40 50 60 75 HD HP 0 33 0 75 5 75 10 15 20 25 30 40 50 60 380V AC ND kW 0 75 4 75 11 15 18 5 22 37 45 55 75 90 132 HD kW 0 55 3 5 5 7 5 11 15 18 5 30 37 45 55 75 110 460V AC ND HP 0 5 7 5 10 15 20 25 30 50 60 75 100 125 150 HD HP 0 33 5 75 10 15 20 25 40 50 60 75 100 125 575V AC ND HP 0 5 10 10 15 20 25 30 50 60 75 100 125 150 HD HP 0 75 7 5 75 10 15 20 25 40 50 60 75 100 125 R 310V DC ND HP 0 5 1 2 75 10 15 20 25 30 40 50 60 75 HD HP 0 33 0 75 1 5 5 7 5 10 15 20 25 30 40 50 60 512V DC ND kW 0 75 4 75 11 15 5 22 37 45 55 75 90 132 HD kW 0 55 3 5 5 5 11 15 18 5 30 37 45 55 75 110 620V DC ND HP 0 5 7 5 10 15 20 25 30 50 60 75 100 125 150 HD HP 0 33 5 75 10 15 20 25 40 50 60 75 100 125 775V DC ND HP 0 5 10 10 15 20 25 30 50 60 75 100 125 150 HD HP 0 75 7 5 75 10 15 20 25 40 50 60 75 100 125 PowerFlex 700S Frame Sizes Drive 1 2 3 4 5 6 9 10 Type Input Duty 2 0 SF 2 0 SF 3 0 SF 6 0 SF 6 0 SF 6 0 SF 6 0 SF 6 0 SF Code Voltage Rating 20 Wide 20 Wide 20 Wide 20 Wide 20 Wide 25 Wide 30 Wide 35 Wide 5 230V AC ND HP 0 5 7 5 10 15 20 25 30 40 50 60 75 NA NA HD HP 10 33 5 75 10 15 20 25 30 40 50
8. 3000 2300H SKG 30 jzj www rockwellautomation com Power Control and Information Solutions Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation SA NV Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication 2362 SG001A EN P September 2005 Supersedes 2362 3 0 April 1997 Copyright O 2005 Rockwell Automation All rights reserved Printed in USA
9. Available to All Units 1 5 Option Option Code Description Horizontal Power 08 AC 800A AC power bus Bu 9 7 11 12 08 DC 800A DC power bus 12 AC 1200A AC power bus 16 AC 1600A AC power bus 16 DC 1600A DC power bus 20 AC 2000A AC power bus 30 AC 3000A AC power bus 30 DC 3000A DC power bus Ground Bus PE XTEP2 PE TE bus for unit with horizontal bus rated up to 2000A Tee XTEP3 PE TE bus for unit with horizontal bus rated up to 3000A 115V AC Control X115 90A control bus Bus Top Hat 12 inch high top hat for extra entry cable bending radius You must select 1 option from this group All drives mounted in the same MCC vertical section must have option 111 if any one drive unit has option 111 You may select up to 1 option from this group Pilot lights are Allen Bradley Bulletin 800M products and the pushbutton is an Allen Bradley Bulletin 800T device If one drive unit has base channels in any lineup the entire lineup must have base channels Base channels add 1 5 inches to the unit height Option 6P is not available for drive units with voltage codes D S E and F Units with voltage codes D S E and F require horizontal power bus options Only 800A 1600A and 3000A are available You must select a ground bus option If your lineup has a 3000A power bus you must select the ground bus option for units with a 3000A rated power bus You must select a horizontal power bus option if you sele
10. Chapter 3 Motor Control Center Vertical Sections Features and Modifications Table 3 A Motor Control Center Vertical Section Features and Modifications Section Features and TT Modifications App Notes Description Sedin An Depth 20 Deep 25 Deep flush back Horizontal 4 Tin plated copper busbar Bus Power Bus Rating 800A 1200A AC only 1600A 2000A 4 5 30004 Horizontal Power 42kAIC rms Symmetrical Bus Bracing 65kAIC rms Symmetrical Horizontal 6 Splice bars and assembly Bus Power Bus hardware Rating Splice Kit 800A 1200A 1600A 2000A 5 6 3000A Horizontal PE TE 4 5 1 4 x 1 PE and 1 4 x 1 TE tin plated copper bus Ground Bus 1 4 x 2 PE and 1 4 x 1 TE tin plated copper bus Horizontal Ground 5 6 For 1 4 x 1 PE and 1 4 x 1 TE tin plated copper bus Bus Splice Kit For 1 4 x 2 PE and 1 4 x 1 TE tin plated copper bus Horizontal Control Bus Tin plated copper 115V AC control bus rated at 90A Horizontal Control Bus 6 For tin plated copper 115V AC control bus rated at 90A Splice Kit Pull Box 12 High x 15 Deep 20 Deep OR 25 Deep Blank Unit Doors Covers unused unit space includes 0 5 SF unit support pan 1 0 SF 1 5 SF 2 0 SF 2 5 SF 3 5 SF 4 5 SF Base Channels 7 8 9 Two 1 5 x 3 mounting channels One front one rear 1 All 1336 D and E frame drive units and
11. HP 300 400 HP 450 600 HP 700 800 HP 775V DC NA 1 3 7 5 20 HP 25 60HP 75 125 HP 150 300 HP 350 400 HP 450 650 HP 700 800 HP ap 230V AC 05 50HP 7 5 15HP 10 30HP NA NA NA NA NA 9 380 460V AC 0 5 5 0 HP 7 5 30HP 40 50 HP 60 125 HP 150 250 HP 300 400 HP 450 600 HP NA 5 575V AC 1 3 HP 7 5 20HP 25 60HP 75 125 HP 150 300 HP 350 400 HP 450 650 HP NA w M 310V DC 0 5 5 0HP 7 5 15HP 10 30HP NA NA NA NA NA 8 512 620VDC 0 5 5 0HP 75 30 40 50HP 60 125 HP 150 250 HP 300 400 HP 450 600 HP 700 800 HP 775V DC 1 3 HP 75 20HP 25 60HP 75 125HP 150 300 HP 350 400 HP 450 650 HP 700 800 HP 1 5 se 5 HP B c 2 E F G 25 SF 5 HP 2 5 SF 3 5 SF 6 0 SF 6 0 SF 6 0 SF 6 0 SF 6 0 SF 20 Wide 20 Wide 20 Wide 20 Wide 25 Wide 35 Wide 35 Wide 35 Wide N 230V AC 05 50HP 7 5 15HP 20 30 HP NA NA NA NA NA 5 380 460V AC 05 15 05 20 30HP 40 50HP 60 125 HP 150 250 HP 300 400 HP 450 600 HP NA 575V AC 0 5 20HP 7 5 20HP 25 60HP 75 125 HP 150 300 HP 350 400 HP 450 650 HP NA LP 310V DC 0 5 5 0HP 7 5 15HP 20 30HP NA NA NA NA NA 0 512 620VDC 0 5 15HP 20 30HP 40 50HP 60 125 HP 150 250 HP 300 400 HP 450 600 HP NA 775V DC 0 5 20HP 7 5 20HP 25 60HP 75 125 HP 150 300 HP 350 400 HP 450 650 HP NA TT NA Not Available
12. M6 6TB 115V AC control power factory wired from 115V AC control bus to drive unit requires control bus 6SC 115V AC control power supplied by customer Auxiliary Contact for 98 1 normally open Y option avail Disconnect 99 1 normally closed Y option avail Wire Label Upgrade 14WLBL Brady Datab wire labels Option T Handles 111 T handles on doors and 3 vertical wireway present in MCC sections containing frame 0 1 2 amp 3 drive units 110 Standard handles Door Mounted 1ES Hardwired interface stop pushbutton for drive disable function Devices 4EA Control power on pilot light 4EW Drive faulted pilot light Miscellaneous J11 Audio phone jack J12 115V AC 15A duplex receptacle Unit Door M3EW Phenolic label with white background and black lettering Nameplates N3EB Phenolic label with black background and white lettering N3ER Phenolic label with red background and white lettering Communication 14PNA No Communication adapter Adapters 14PCNC DPI ControlNet adapter coaxial cable 14PCNF DPI ControlNet adapter fiber optic 14PDF1 DPI RS485 DF 1 adpater 14PDPV1 DPI PROFIBUS DPV 1 adapter 14PEA DPI Ethernet adapter 14PG1 DPI Single Point Remote I O RIO adapter 14PG5 DPI DeviceNet adapter 14PHVA DPI RS485 HVAC adapter future 14PIB DPI Interbus adapter future 14PLW DPI LonWorks adapter future Communication 14DLD ELC DeviceNet adapter oo 14DLE ELC EtherNet adapter Oniy 1 15 14DL
13. O signals etc Note NEMA Type 1 is the standard feature and NEMA Type 1 with unit door area gaskets and door fan filters is available as an option A variety of available options provide increased unit functionality The following drive units are available Drive Frames Unit Type 1336 A B C plug in D E F G roll out PowerFlex 0 1 2 3 plug in 4 5 6 9 frame mounted Plug In Drive Units The basic standard plug in drive unit includes e the selected drive mounted and wired in an MCC bucket e a fused disconnect switch with an operator mechanism and appropriate fuses e power and ground stabs for connecting to bus structure e stab to disconnect wiring e output common mode chokes e aunit support pan e a vented door with fan s if appropriate Note MCC units that contain plug in buckets come standard with manual vertical bus shutters Frame Mounted Drive Units The basic standard frame mounted drive unit includes e the selected drive mounted and wired on a panel mounted assembly e a fused disconnect switch with an operator mechanism and appropriate fuses e bus to disconnect wiring e output common mode chokes e avented door with fan s if appropriate UL Certification Documentation Introduction p 3 Roll Out Drive Units The basic standard roll out drive unit includes e the selected drive mounted and wired on a roll out chassis assembly e afused disconnect switch with an operato
14. Phase ll with expanded cassette with Logix extras with SynchLink 14CIOG Phase slim cassette no Logix extras no SynchLink 14CIOH Phase II slim cassette no Logix extras with SynchLink Configurations ELC2SNN Phase Il no DriveLogix no embedded comm ELC2SNE Phase Il no DriveLogix EtherNet IP embedded comm ELC2SNC Phase Il no DriveLogix ControlNet embedded comm ELC2SEN Phase Il 5730 DriveLogix no embedded comm ELC2SEE Phase Il 5730 DriveLogix EtherNet IP embedded comm ELC2SEC Phase Il 5730 DriveLogix ControlNet embedded comm Compact I O CIOL Drive to left bank expansion Cable CIOR Drive to right bank expansion Feedback 14ENC Standard encoder wi Flex 700 No feedback PCB Feedback 14EN2 Second encoder feedback 4 wi 687005 Heidenhain feedback PCB 14HENC Hi Resolution Stegmann resolver feedback Pca 14MDI Multi Device Interface 1 14PN No feedback PCB 14RES Resolver feedback PCB 14S0 Safe Off includes second encoder feedback Braking Option 16BI Braking IGBT included 16BNI Braking IGBT not included Braking Resistor 14BR Braking resistor included 14BRN Braking resistor not included 14BRE Braking resistor external Enclosure Options MCC Bottom XBC 1 5 inch high base channels 1 5 Support XBSM Bottom support angle multi section PowerFlex 700 and 700S Product Selection Options
15. OC ELC ControlNet adapter coaxial cable 14DLOF ELC ControlNet adapter fiber optic 14DLORC ELC ControlNet Redundant adapter coaxial cable 14DLORF ELC ControlNet Redundant adapter fiber optic Human Interface 14HAPC Door mounted HIM Programmer Only LCD Module HIM asc Door Mounted HIM with full numeric LCD HA1C Drive Mounted Him with analog LCD HA2C Drive Mounted HIM with digital LCD HA3C Drive Mounted HIM with full numeric LCD HAP Door Mounted HIM Programmer Only LCD Drive Enclosure 0 Open 14D1 NEMA 1 14D12 NEMA 12 14DF Flange 1 4 PowerFlex 700 and 700S Product Selection Options Available to All Units Option Option Code Description Drive Duty Cycle 99ND Normal Duty 99HD Heavy Duty Emissions 14EMA CE filter and common mode choke 19 21 14EMB CE filter and no common mode chokel9 2 14EMB1 CE filter and external common mode choke 14EMN No CE filter and no common mode choke 22 23 14EMN1 No CE filter and external common mode choke 22 23 Documentation In No documentation A English User Manual E Quick Start Guide and CD 1 0 Selection 1410C Vector I O 24V ot FEN on Vector O 115V Control PowerFlex 140108 Phase with expanded cassette Logix extras no SynchLink 7008 Only 14CIOB Phase with expanded cassette no Logix extras with SynchLink 14CIOC Phase with expanded cassette with Logix extras no SynchLink 14CIOD
16. common DC bus F frame drive units and PowerFlex frames 4 9 have 20 deep sections as standard Common AC bus F frame drive units and all G frame and H frame drive units have 25 bump back sections as standard If you are using a Bulletin 2364 front end common DC bus supply unit in your lineup verify that the front end depth is compatible with the Bulletin 2362 sections that you are selecting If ANY one section is at least 20 deep then ALL sections in that lineup must be at least 20 deep You must specify a power bus and a ground bus for each section 3000A rated horizontal power bus requires a 1 4 x 2 horizontal ground bus PE selection Zero potential bus TE remains at 1 4 x 1 regardless of horizontal ground bus PE size selection Splice kits with 1 4 x 2 PE contain three 1 4 x 1 bus splices Qty 2 for PE Qty 1 for TE splice kits with 1 4 x 1 PE contain two One kit required per shipping split on flush front lineups Control bus splice kits are only required if lineup has control bus Common AC bus F frame drive units and all G frame and H frame drive units require base channels If you are using a Bulletin 2364 front end unit in your lineup lookup the base channel requirements of the front end being utilized If ANY one section has base channels then ALL sections in that lineup must have this optional base channel factory installed Base channels add 1 5 to the overall section height PowerFlex frame 10 requires a 25
17. ct a control bus Units come standard with cloth wire labels Datab labels offer the added protection of a clear plastic cover on top of the labels 1 Horizontal power bus is braced for 65kAIC 12 Maximum of 120 inches per shipping split 13 Requires an expended cassette for Phase control 14 Available for Phase Il control only Requires an expanded cassette 15 For dual communications DPI and DriveLogix select the DriveLogix comm option and order the DPI comm kit separately 16 PowerFlex 700 frame 0 6 allows the N or A selections only PowerFlex 700 frame 9 allows the A selection only PowerFlex 700S frames 1 9 allows the N or E selections only 17 PowerFlex 7005 only requires an expanded cassette with Logix extras PCB 18 Required for PowerFlex 7008 frames 1 6 19 Required for PowerFlex 700 frames 0 6 with voltages 380V AC 460V AC 575V AC 512V DC 620V DC and 775V DC 20 Required for PowerFlex 700 frames 0 2 with voltages 230V AC and 310 V DC 21 You must select one 1 of these options for PowerFlex 700 frame 3 with voltages 230V AC and 310 V DC 22 You must select one 1 of these options for PowerFlex 700S frame 9 with voltages 380V AC 460V AC and 575V AC 23 You must select one 1 of these options for PowerFlex 7006 frame 9 with voltages 512V DC 620V DC and 775V DC 223333932382 2339333352352 1 6 PowerFlex 700 and 700S Product Selection Notes Chapter 2 1336 PLUSTM Variab
18. deep flush back section oa fF wo N 200 x0 3 2 Motor Control Center Vertical Sections Notes Chapter d Busbar Splice Kits Understanding Busbar Each character of the catalog number identifies a specific type or size of a Splice Catalog Numbers particular busbar splice kit The first four numbers represent the family of products for example 2300 The remaining characters represent a specific version Determining Splice Kit Catalog Numbers To help you to understand we will provide an example of how to determine a catalog number for a Bulletin 2300 Family busbar splice kit The beginning portion of the catalog number for all 2300 busbar splice kits is 2300H H is for a hardware kit The remaining portion of the catalog number will represent the particular type of kit The catalog number is organized as follows 2300 H SK Busbartype Busbarspliceshape Power Bus Current Rating For example a catalog number on the following page for 2300H SKA Z16 would mean e acommon AC power bus system e a power bus rating of 1600 Amps e an offset splice is needed Splice Kit Catalog Numbers Power Bus Splice Kit Catalog Numbers For Use Splicing directly to a common AC bus F frame Table 4 0 2362 unit or any G frame 2362 unit All other AC common bus splicing applications Table 4 A All DC common bus splicing applications Table 4 B Table 4 4 AC Power Bus Splice Kits Compatible with Frame Si
19. ic label with white background and black lettering Nameplates gEB Phenolic label with black background and white lettering N3ER Phenolic label with red background and white lettering Communication 14CN1 DPI SCANport to ControlNet adapter Adapters 14G1 SCANport to Single Point Remote I O RIO adapter 14G2 SCANport to RS232 422 485 DF1 or DH485 adapter 14G5 SCANport to DeviceNet adapter Human Interface 14HA1C Door mounted HIM with analog potentiometer Module HM 14HA2C Door mounted HIM with digital potentiometer 14HAPC Door mounted HIM Programmer Only LCD 14HNBC Door mounted connector permitting connection of a hand held HIM or GPT through closed door unit Options Available to 2362E amp 2362G Units Option Option Code Description Control Logic 14L5 24V DC aera 14L5E 24V DC with encoder feedback 14L6 115V AC 14L6E 115V AC with encoder feedback Languages 14DE English German 14EN English English 14ES English Spanish 14FR English French 14IT English ltalian 2 4 1336 PLUS Variable Frequency 1336 PLUSTM II 1336 FORCE Vector Control 1336 IMPACT Product Selection Options Available to 2362F amp 2362H Units Option Option 6006 Description Control Logic 1415 24V DC meres 14L6 115V AC Drive Adapter 14CN ControlNet version 1 5 Adapter Boards 14PCA PLC Comm Adapter 14SA Standard Adapter If you selected Control Logic Interface Board 14L5 or 14L6 you must choose this Dr
20. ive Adapter Board Languages 14EN English English 14ES English Spanish 14FR English French Options Available to 2362L amp 2362M Units Option Option Code Description Control Logic 14L5 24V DC MeS 14L6 115V AC 14L8E 24V DC with encoder feedback and encoder loss detection 14L9E 115V AC with encoder feedback and encoder loss detection Languages 14DE English German 14EN English English 14ES English Spanish 14FR English French 141T English Italian Options Available to 2362N amp 2362P Units Option Option Code Description Control Logic 14L5 24V DC Interface Boards sE 24V DC with encoder feedback 14L6 115V AC 14L6E 115V AC with encoder feedback 14L8E 24V DC with encoder feedback and encoder loss detection 14L9E 115V AC with encoder feedback and encoder loss detection Analog Interface 14LA2 2 isolated configurable inputs Board Port AU 14LA6 3 non isolated thermistor RTD inputs 14LA7 1 isolated bipolar input 10V and 1 isolated configurable input 14LA1 1 single ended non isolated configurable input OR 1 potentiometer amp 2 single ended non isolated 1 to 20mA outputs Port B 14LA3 2 isolated configurable outputs 14LA4 1 isolated configurable input and output 14LA5 1 isolated pulse input and output amp 1 single ended non isolated 0 to 10V output
21. le Frequency 1336 PLUS Il 1336 FORCE Vector Control 1336 IMPACT Product Selection Catalog Number Use the following tables for determining the catalog number used to order Explanation 1336 PLUS M Variable Frequency 1336 PLUS M II 1336 FORCE Vector Control and 1336 IMPACT drives in Bulletin 2362 MCCs OPTIONS Frame Size Input Voltages Disconnect Type See Table 2 B on A 230V AC Bus DA Fused Disconnect page 2 3 N 380V AC Bus B 460V AC Bus Options el See Drive Unit Options on page 23 ELE ee Tr a us B A a NN with F IEN DC Bus Horsepower Rating A Type Power Wiring with gt 03 Top Exit 34 75 35 1 0 36 115 37 2 0 Drive Type Enclosure BE E 13368 PLUS AC Common Bus A NEMA Type 1 with no EE 1336T FORCE AC Common Bus gaskets or door fan filters 40 175 G 13368 PLUS DC Common Bus J NEMA Type 1 with gaskets 4 110 H 1336T FORCE DC Common Bus or door fan filters 215 L 1336E IMPACT AC Common Bus 43 20 M 18368 IMPACT DC Common Bus 44 25 1336E PLUS II AC Common Bus 45 30 P 11336E PLUS II DC Common Bus 46 40 47 50 48 160 49 75 50 100 51 125 52 150 54 200 56 250 57 1300 58 0 59 1400 60 0 61 0 62 0 63 0 64 1700 66 800 2 2 1336 PLUSTM Variable Frequency
22. listed in Table 1 A e select drive unit options using Table 1 B e select MCC vertical sections selected using Table 3 A For 1336 drive units listed in Table 2 A e elect drive unit options using Table 2 B e select MCC vertical sections selected using Table 3 A If there is a need to purchase a separately assembled unit for example if a spare unit is desired select the unit as listed in Table 1 A or Table 2 A When constructing the catalog number string use the N enclosure designation for NO structure assembly Options or equipment not offered through the 2362 standard AC drive unit program can be provided to you as an engineered solution Contact your local Rockwell Automation Drive Systems representative Bulletin 2362 AC motor drive units are specifically designed for use in CENTERLINE MCC lineups You may select from numerous 1336 PLUS Variable Frequency 1336 PLUS II Variable Frequency 1336 FORCE Field Oriented Control Vector 1336 Impact PowerFlex 700 and PowerFlex 700S digital AC motor drives You may have these drives configured for either a common AC or a common DC power bus configuration NEMA Class I Type A rated units are standard To provide either a NEMA Type 1 ora NEMA Type 1 with gaskets enclosure rating the unit must be installed into an appropriately sized MCC vertical section Terminals p 2 Introduction mounted within the drive units allow for the connection of remote operator devices I
23. losure units in a lineup must have the same horizontal power bus option The horizontal power bus rating of the entire lineup equals the lowest power bus rating selected 14 Horizontal power bus is braced for 65kAIC 15 Maximum of 120 inches per shipping split 16 Horizontal power bus and control bus if selected are mounted at a depth of 11 94 inches in all MCC sections containing frame A B and C drive units regardless of section depth Frame D E F G and H drives units have power bus and control bus if selected mounted at a depth of 16 94 inches or greater with bus ends for splicing always at a depth of 16 94 inches Select offset splice kit s when shipping split requires splicing bus ends at a depth of 11 94 inches to bus ends at a depth of 16 94 inches If both sections have bus ends at the same depth select straight splice kits Use the tables in the Power Bus Splice Kit Catalog Numbers section on page 4 1 to select splice splits per shipping split 17 Frame F G and H drive units require top hats if input power is not supplied by a power bus option 18 Requires an expended cassette for Phase II control 1 9 Available for Phase control only Requires an expanded cassette 20 For dual communications DPI and DriveLogix select the DriveLogix comm option and order the DPI comm kit separately 2 6 1336 PLUSTM Variable Frequency 1336 PLUS II 1336 FORCE Vector Control 1336 IMPACT Product Selection Notes
24. r mechanism and appropriate fuses e bus to disconnect wiring e output common mode chokes in all D E and F frame units and in G frame 2362H units common DC bus 1336 FORCE e a vented door with fan s if appropriate Note All and E frame units and common DC bus F frame units are mounted in 20 deep vertical sections Common AC bus F frame units and all G frame units are mounted in 20 5 bumpback deep vertical sections for ease of serviceability Bulletin 2100 CENTERLINE Motor Control Centers are certified by Underwriters Laboratories Inc UL Standard UL 845 The 2362 family of AC drive units are UL cUL listed All vertical sections and units certified by UL will carry the label Vertical sections and units are labeled separately The customer is supplied with copies of the following e the unit wiring diagram and installation instructions e publications Bulletin 2300 Drive Systems Installation Manual 2300 5 1 the appropriate AC drive user manual Receiving Handling and Storing Motor Control Centers 2100 5 5 For additional documentation consult your Rockwell Automation Sales Office p 4 Introduction Notes Chapter 1 PowerFlex 700 and 700S Product Selection Catalog Number Use the following tables for determining the catalog number used to order Explanation PowerFlex 700 and 7005 drives in Bulletin 2362 MCCs OPTIONS Frame Size See Table 1 A on page 1 2 Inp
25. u may select up to 1 option from this group 4 Pilot lights are Allen Bradley Bulletin 800M products and the pushbutton is an Allen Bradley Bulletin 800T device 5 lf one drive unit has base channels in any lineup the entire lineup must have base channels Base channels add 1 5 inches to the unit height 6 Option 6P is not available for drive units with voltage codes D S E and F 7 lf you are connecting to an FD86N cabinet you must select base channels and enclosures that are 20 inches and or 25 inches deep 8 Units with voltage codes D S E and F require horizontal power bus options Only 800A 1600A and 3000A are available 9 You must select a ground bus option If your lineup has a 3000A power bus you must select the ground bus option for units with a 3000A rated power bus 10 You must select a horizontal power bus option if you select a control bus 11 Units come standard with cloth wire labels Datab labels offer the added protection of a clear plastic cover on top of the labels 12 If at least one unit in a lineup is 20 inches or 25 inch deep flush back then all other drive units in that lineup must be 20 inches or 25 inches deep 13 If the drive unit is mounted in a 25 inch deep flush front enclosure you must select a 3000A horizontal power bus for that unit If you have drives mounted in 15 inch or 20 inch deep sections in the same lineup you may select a different horizontal power bus option but all non 25 inch deep enc
26. ut Voltages A 230V AC Bus 380V AC Bus 460V AC Bus 1575V AC Bus 310V DC Bus 512V DC Bus 1620V DC Bus 1775V DC Bus Disconnect Type DA Fused Disconnect Options See Table 1 B on page 1 3 Wiring Type A A Type 8 A Type Power Wiring with Bottom Exit A Type Power Wiring with Top Exit ar Ar Horsepower Rating 85 3 33 5 34 10 75 35 11 0 Drive Type Enclosure ey PowerFlex 700 AC Common Bus A NEMA Type 1 with je PowerFlex 700 DC Common Bus gaskets or door fan filters 38 3 0 PowerFlex 7005 AC Common Bus J NEMA Type 1 with gaskets 39 0 PowerFlex 7005 DC Common Bus or door fan filters 2 a 42 115 43 20 44 25 45 30 46 40 47 50 48 60 49 75 50 100 51 1125 52 150 54 200 56 250 57 300 58 1350 59 400 60 0 61 500 62 600 63 1650 64 700 66 1800 1 2 PowerFlex 700 and 700S Product Selection Frame Selection The following table is used to determine the frame size required based on the desired Drive Type Input Voltage and Horsepower Table 1 A PowerFlex 700 ad 7005 Frame Selection PowerFlex 700 Frame Sizes Drive 0 1
27. zes Continuous Power Bus 1336 PowerFlex Rating Amps Straight Splice Kit Offset Splice Kit A B C D E 9 800 2300H SKA L08 2300H SKA Z08 A B C D E 9 1200 2300H SKA L12 2300H SKA Z12 A B C D E 0 9 1600 2300H SKA L16 2300H SKA Z16 A B C D E 0 9 2000 2300H SKA L20 2300H SKA Z20 A B C D E 9 2500 2300H SKA L25 2300H SKA Z25 A B C D E 9 3000 2300H SKA L30 2300H SKA Z30 F G H Up to 3000 2300H SKA L30S 2300H SKA Z30 4 2 Busbar Splice Kits Table 4 B DC Power Bus Splice Kits Compatible with Frame Sizes Continuous Power Bus 1336 PowerFlex Rating Amps Straight Splice Kit Offset Splice Kit A B C D E 9 800 2300H SKD L08 2300H SKD Z08 A B C D E 9 1600 2300H SKD L16 2300H SKD Z16 A B C D E F 0 9 3000 2300H SKD L30 2300H SKD Z30 G H Up to 3000 2300H SKD L30S 2300H SKD Z30 Table 4 C Special Power Bus Splice Kits Use these kits when splicing directly toa Common AC Bus F frame 2362 Unit or any G frame 2362 Unit Power Bus Rating Amps Straight Splice Kit 600 3000 2300H SKA L30S Offset Splice Kit 2300H SKA Z30 Control Bus Splice Kit Catalog Numbers Table 4 D Control Bus Splice Kits Compatible with Frame Sizes Straight Splice Kit Offset Splice Kit All 2300H SKC L 2300H SKC Z PE TE Bus Splice Kit Catalog Numbers Table 4 E PE TE Bus Splice Kits Compatible with Frame Sizes Power Bus Rating Amps PE TE Bus Splice Kit All 800

Download Pdf Manuals

image

Related Search

Related Contents

Pioneer dvd-114 User's Manual  Traitement des chants au Luko - 182 Ko  《USER MANUAL》 Smart Home Control Terminals  Slendertone System Armtrainer für SIE  西 東 北 図 包  Ayuda Biologica para la Raza Humana™    AE36型およびAE36A型自動空気抜き弁取扱説明書  KESSEL Grease Separator Euro “G” NS 1, 2 and 4 for underground  XS WIRELESS  