Contents
1. AAMPROBE PY 1A AC DC Voltage Tester Users Manual e Mode d emploi e Bedienungshandbuch Manual d Uso e Manual de uso Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Amprobe5 behalf To obtain service during the warranty period return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor See Repair Section for details THIS WARRANTY IS YOUR ONLY REMEDY ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STAUTORY INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY ARE HEREBY DISCLAIMED MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages this limitation of liability may not apply to you Repair All test tools returned for warranty or non warranty repair or for calibration should be accompanied by the following your name company s name address tele
2. necessary Double check operating procedure as described in this user s manual Visit www Amprobe com for Catalog Application notes Product specifications User manuals e Please Recycle
3. 82 1 are fulfilled It also complies with the low Voltage Directive 73 23 EEC Standard EN 61010 1 is fulfilled Measurement category III is for measurements performed in the building installation Instrument complies with the standard 2002 96 EEC WEEE A The instruction manual contains information and references nessary for safe operation and maintenance of the instrument AWarnings This Electrical Tester has been constructed and verified in compliance with the lasted safety standards and have left the factory in safe and perfect conditions Prior to using the instrument commissioning assembly the user is kindly requested to thoroughly read the instruction manual and comply with it in all sections Failure to read the instruction manual or to comply with the warnings and references contained herein can result in serious bodily injury or instrument damage 2 The respective accident prevention regulations established by the professional associations for electrical system and equipment must be strictly met at all times In order to avoid electrical shock the valid safety regarding excessive contact voltages must receive utmost attention when working with voltages exceeding 120V 60V DC or 50V 25V rms AC The values in bracket are valid for limited ranges as for example medicine and agriculture Never connect the tester to voltage for longer than 30 seconds For next operation a recove
4. CIFICATION Voltage Range Response Time Frequency Range Interal Load Test Current Operation Time DT Recovery Time Temperature Range 120 240 277 480V AC 160 330 380 600V DC 0 3s DC 0 65Hz approx 2 0 W 600V 3 5 mA 30s 240s 5 C 40 C 41 F 104 F Humidity Max 80 rel H Height above sea level up to 2000 m 6562 ft Measurement Cat CATIII 600V Pollution Degree 2 Safety Standards IEC 61010 UL 61010 CSA 22 2 No 61010 Weight Approx 50g 0 11 Ib Dimension Approx 150X32X26 mm 5 9x1 3x1 0 in MAINTENACE When using the instrument in compliance with the instruction manual no special maintenance is required Should operational problems occur during daily use our consulting service will be at your disposal free of charge If functional errors occur after expiration of warranty the repairing of the tester should be performed only by a Factory Authorized Service Center or by other qualified instrument service personnel The front panel and case can be cleaned with a mild solution of detergent and water Apply sparingly with a soft cloth and allow to dry completely before using Do not use aromatic hydrocarbons or chlorinated solvents for cleaning Do not attempt to repair this tester It contains no user serviceable parts Repair or servicing should only be performed by qualified personnel TROUBLE SHOOTING If the instrument fails to operate check test leads and replace as
5. obe Test Tools distributor for a nominal charge Please check the Where to Buy section on www amprobe com for a list of distributors near you Amprobe Test Tools Europe In den Engematten 14 79286 Glottertal Germany tel 49 0 7684 8009 0 Correspondence only no repair or replacement available from this address European customers please contact your distributor PY 1A AC DC Voltage Tester nre PY 1A AC DC Voltage Tester 480V 600V nm 277V 380V 240V 330V lm f DC 0 65Hz 1 3 5mA 600V Test Probes Neon for Voltage indication Pocket Clip CONTENTS SYIMBOLS u sn dy nce mette itn ENEE UNPACKING AND INSPECTION INTRODUCTION a OPERATION entere in e E dn rmt SPECIFICATION eegen MAINTENANCE nnne TROUBLE SHOOTING SYMBOLS A Warning of a potential danger comply with instruction manual Caution Dangerous Voltage Danger of electrical shock Continous double or reinforced insulation complies with Category II IEC 536 C Confirmity symbol the instrument complies with the valid directives It complies with the EMC Directive 89 336 EEC Standards EN 50081 and EN 500
6. phone number and proof of purchase Additionally please include a brief description of the problem or the service requested and include the test leads with the meter Non warranty repair or replacement charges should be remitted in the form of a check a money order credit card with expiration date or a purchase order made payable to Amprobe Test Tools In Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product Please check the Where to Buy section on www amprobe com for a list of distributors near you Additionally in the United States and Canada In Warranty repair and replacement units can also be sent to a Amprobe Test Tools Service Center see next page for address Non Warranty Repairs and Replacement US and Canada Non warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates In USA In Canada Amprobe Test Tools Amprobe Test Tools Everett WA 98203 Mississauga ON L4Z 1X9 Tel 888 993 5853 Tel 905 890 7600 Fax 425 446 6390 Fax 905 890 6866 Non Warranty Repairs and Replacement Europe European non warranty units can be replaced by your Ampr
7. rences the technical data including environmental conditions and the usage in dry environments must be followed When modifying or changing the instrument the operational safety is no longer ensured The instrument may only be used under those conditions and for which it was conceived For this reason in particular the safety references the technical data including the environmental conditions and the usage in dry environments must be followed UNPACKING AND INSPECTION Your shipping carton should include 1 Electrical Tester PY 1A 1 Instruction Manual If any of the items are damaged or missing return the complete package to the place of purchase for an exchange INTRODUCTION This Electrical Tester is for universal applications for indoor use only It represents a valuable support for all testing in handicraft and industrial applications The electrical tester is characterized by the following features upto 600V AC voltage detection up to 480V and DC voltage Bright neon AC DC voltage display Ergonomically and robust housing Snap in leads are spaced to fit to the standard US Canada outlet for easy one hand operation OPERATION Integral probe storage for easy carrying Test the electrical tester on a known source Connect both test leads with UUT The voltage is displayed via Neon lamps The instrument with 120 240 277 480V AC range and 160 330 380 600V DC range SPE
8. ry time of minimum 240 seconds is needed The instrument may only be used within the operating ranges as specified in the technical data section and in low voltage system up to 600V Measurements in dangerous proximity of electrical system are only to be carried out in compliance with the instructions of a responsible electronics technician and never alone The electrical testers may no longer be used if one or several functions fail or if no functionality is indicated Do not use this instrument under damp conditions Perfect display is only guaranteed within a temperature range of 5 C up to 40 C at relative humidity 8096 Test leads and test probes may only be touched at handle surfaces provided Absolutely avoid the direct contact of the rest probes Prior to usage ensure perfect instrument function e g on known voltage source The instrument may only be opened by an authorized service technician The safety can no longer be insured if the instrument Shows obvious damage Does not carry out the desired measurements Has been stored for too long under unfavorable conditions Has been subjected to mechanical stress during transport Avoid any heating up of the instrument by direct sunlight to ensure perfect functioning and long instrument life The instrument may only be used under those conditions and for those purposes for which it was conceived For this reason in particular the safety refe
Download Pdf Manuals
Related Search
Related Contents
CONTROLADOR UNIVERSAL N120 & N120S OLIMEXINO-32U4 development board USER`S MANUAL BGR-88-116 handleiding 2008.indd Français - Came Europe NSAM266SP Compact SPEECH Digital Speech Processor with Full CD12 User Manual - Stanley Hydraulic Tools 入 札 説 明 書 Philips Stereo Y cable SWA2885W KCA-iP500 7500 User Manual Copyright © All rights reserved.