Home

water line

image

Contents

1. pillar into position using the supplied fittings See Figure 2 7 4 Installation Queen Pearl for integrated fitting WATER LINE Installation must be carried out by a qualified fitter carbonated water Water IN oo q Installation of Queen Pearl for integrated fitting 6 Connect the water hose from carbonated water on the cooling unit to carbonated water on the tap pillar Then connect the water hose from cold water on the cooling unit to cold water on the tap pillar Mount the gas dome A on the carbon dioxide cylinder B and then fit the supplied nipple on the gas dome Connect the carbon dioxide cylinder to cooling unit inlet CO2 using the hose C Fit the water filter D and connect the filter to the water cooling unit inlet using the hose E Connect the supplied 1 2 hose to the water filter and then to the water main It is recommended that you connect the hose to a shut off tap Check that no kinks or sharp bends have formed on the hoses during connection Fit the drip tray and the tap bosses See page 9 IMPORTANT Fill with water Before starting the cooling unit it must be filled with water Lift the cooling unit cover and fill the cooling tank with tap water until water runs out from the drain valve drainage cooling tank Connect the plug to an earthed 230V 10A wall socket Flush out approx 2 5 litres of chilled still water and then approx 2 5 litres of carbonated water befo
2. ER LINE Installation must be carried out by a qualified fitter CHILLER SYSTEM INSTALLATION AND SITING See page 12 Figure 2 Installation of Queen Pearl for integrated fitting 1 The machine must be placed on a flat surface that is impermeable to water The tap pillar shall be fitted on material that has a high stress tolerance and is impermeable to water Install the machine using the supplied water filter hose connections water hoses and gas dome If necessary use a spirit level Installation in cabinet NB The cooling unit must be installed in a well ventilated area that is at normal room temperatur approx 16 C 28 C Make sure air is able to circulate freely around the cooling unit IMPORTANT The machine must be disconnected from the mains before any work is carried out Pull the mains cable from the wall socket The end customer user is responsible for ensuring that the water connection is compliant with the manufacturer s instructions NOTE WORKING WITH THE CONNECTIONS Hold the connection and press the hose as far into the connection s body as possible Disconnecting the John Guest connection Push the grey ring out towards the connection and pull out the hose ER Em If the water hoses need to be cut make a straight cut in order to prevent leakage Fae the tap pillar Fit the tap pillar A by drilling a 50mm diameter hole in the bench top See Figure 1 Screw the tap
3. User Manual QUEEN PEARL with base cabinet PEARL integral Serves chilled still and carbonated water ef fl COFFEE Your retailer U EN Rev 090914 QU en ee Ne Contents Contents Notes for the user Using the machine Installation Queen Pearl with base cabinet Installation Queen Pearl for integrated fitting Care and maintenance replacing a water filter Cleaning the machine Important WATER LINE 2 Notes for the user Queen Pearl WATER LINE Thank you for choosing a Queen Pearl water dispenser we hope you will enjoy the benefits of using it Queen Pearl is supplied with a base cabinet Pillar with 2 tap outlets and base cabinet with cooler Base cabinet made from stainless steel plate with painted side panels Top board in wood Dispenses both chilled still and chilled carbonated water Read the manual carefully before using the machine for the first time It contains important instructions for the correct and safe use of the machine Always keep the manual in a place that can be easily accessed by the user Technical data Height Width Depth Power supply Cold water connection Cooling capacity Refrigerant Power Automatic water replenishment Chilled water Carbonated water Gas dome nipple Water filter Carbon dioxide cylinder Carbon dioxide cylinders may be purchased from your local gas distributor TECHNICAL SPECIFICATIONS Chiller System AS45 Drink temperatur
4. e Power supply Coolant Vessel volume Weight External dimensions Width Height Depth Pearl Pearl with base cabinet 480 tap pillar 1325 170 tap pillar 400 400 230V 10A 230V 10A 1 2 1 2 B 40 litres per hour 40 litres per hour HFC 134A HFC 134A Single phase 453W Single phase 647W Yes Yes Yes Yes Yes Yes supplied supplied supplied integral NO No height 580 x width 185 height 580 x width 185 5 8 C 230 V 50 Hz R 134a 141 32 kg 435 mm 490 mm 415 mm 3 Using the machine Queen Pearl WATER LINE Outlet for carbonated water Outlet for still water Chilled drink outlet Queen Pearl has two chilled drink outlets Hold a glass under the outlet for your selected drink Pull the handle forwards and the water will flow for as long as you keep the handle pulled See Figure 1 Figure 1 4 Installation Queen Pearl with base cabinet WATER LINE Installation must be carried out by a qualified fitter Installation of Queen Pearl base cabinet 1 Place the machine on a flat surface that is impermeable to water If necessary use a spirit level and adjust using the machine s adjustable feet Make sure air is able to circulate freely around the machine Min 10cm IMPORTANT The machine must be disconnected from the mains before any work is carried out Disconnect the power supply cable from the wall socket The end customer user is responsible
5. e to break down The machine should stand on a flat surface so that it will function properly The machine must be placed on a surface that is impermeable to water so that any leaks will be visible Make sure that no kinks are formed in the hose during installation or when machine is moved into position The machine s hose and HVAC connections must be checked on a regular basis Make sure that no leakage has occurred in connection with installation With a water connection there is always a danger of leakage regardless of any safety equipment used If the machine is to be put into storage for an extended period of time it must be completely drained of water Shut off the water taps if the machine is not to be used for an extended period of time Before carrying out any maintenance the machine must be disconnected from the mains electricity supply by pulling the plug from the wall socket INSTALLATION AND SITING CHILLER SYSTEM The system is designed to be used in standard environments in accordance with CSN standard 33 2000 3 and is included in climate class N It must not be sited close to a heating source or exposed to direct sunlight The system is designed to be used in ambient temperatures of between 6 C minimum and 28 C maximum The system must not be used or sited in areas with an ambient temperature below 0 C ELECTRICAL CONNECTION Connect the system to 220 240 V 50 Hz and 10 A The electrical installation plug m
6. for ensuring that the water connection is compliant with the manufacturer s instructions NOTE WORKING WITH THE CONNECTIONS Hold the connection and press the hose as far into the connection s body as possible Disconnecting the John Guest connection Push the grey ring out towards the connection and pull out the hose E mm If the water hoses need to be cut make a straight cut in order to prevent leakage 4 Installation Queen Pearl with base cabinet WATER LINE Installation must be carried out by a qualified fitter Installation of Queen Pearl with base cabinet Install the machine using the supplied water hoses and gas dome 4 5 Undo the rear section of the machine Mount the gas dome A on the carbon dioxide cylinder B and then fit the supplied nipple on the gas dome Connect the carbon dioxide cylinder to the cooling unit using the water hose C Connect the supplied 1 2 hose to the machine D and then to the water main It is recommended that you connect the hose to a shut off tap Check that no kinks or sharp bends have formed on the hoses during connection Fit the tap bosses see Figure 1 Fit the drip tray E Connect the plug to an earthed 230V 10A wall socket u Flush out approx 2 5 litres of chilled still water and then approx 2 5 litres of carbonated water before putting the machine into use 4 Installation Queen Pearl for integrated fitting WAT
7. re putting the machine into use 4 Installation Queen Pearl for integrated fitting WATER LINE Installation of drip tray and tap handles Installation must be carried out by a qualified fitter 14 Place the drip tray under the tap pillar See Figure q Drip tray Screw the supplied handles in position See Figure 4 5 Care and maintenance Water Line Fitting and replacing the water filter To be replaced every 6 months The machine is supplied with a water filter that must be replaced every 6 months in order to retain the quality of the water REPLACEMENT OF WATER FILTER The water filter can be replaced under pressure 1 Remove the filter cartridge by rotating it a quarter turn See Figure 1 2 Fitthe new filter cartridge by rotating it a quarter turn See Figure 1 Water filter bee Filterpatron sett underifr n Only use Coffee Queen water filters Article no 1505344 IMPORTANT Before the machine is put back into use Hold a glass under the outlet for your selected drink Pull the cold water handle forwards until water comes out See Figure 2 Figure 2 6 Cleaning the machine Daily cleaning Queen Aqua Pearl Daily cleaning or as required Clean with a moist non abrasive cloth Empty and clean the drip tray and the drip tray insert every day 7 Important WATER LINE Important Do not make any alterations to the machine Doing so may result in personal injury and cause the machin
8. ust be compliant with applicable CSN regulations EN and ISO standards If the cable is damaged it must be replaced by qualified personnel This is to prevent accidents TEMPERATURE AND SETTINGS The temperature of chilled drinks is controlled by means of a mechanical temperature regulator between 3 C and 10 C There is a scale from 1 to 7 on the temperature regulator 1 approx 10 C 7 approx 3 C 0 off CONNECTION AND SERVICE The condenser shall be cleaned every 6 months in conjunction with replacing the water filter When cleaning use compressed air Do not place anything on the chiller that may hinder air circulation Only clean when the chiller is not under power All installation work must be carried out by qualified personnel 12 WATER LINE COFFEE QUEEN ORIGINAL FOR SERVICE Please contact Your local retailer CREM International AB Box 960 SE 671 29 ARVIKA Sweden Tel 46 0 570 477 00 Fax 46 0 570 47719 E mail info se creminternational com www creminternational com Art no 1730010

Download Pdf Manuals

image

Related Search

Related Contents

Manual coating equipment OptiFlex 2 Q  BH-MH20FC User manual(PDF Format)  Cerberus CerGas Software tool SWE60 User manual  Zu dieser Anleitung  取扱説明書  smxFS User's Guide (FAT12/16/32 File System)  Istruzioni ETRUSCA BIO  Bracketron Twist360  IB-120CL-U3 Station d`accueil 2 baies et station de clonage pour  RALLYE DE NOUVELLE CALEDONIE  