Home
        IEPS5 User Manual
         Contents
1.    DC chargers are able to deliver up to 2 5 times the rated current when mains power is on     Connection polarity   It is critical to check the polarity carefully when connecting DC devices  Some Innovative Energies models have re   verse polarity protection  RPP   for example  the Smartchargers have electronic  non destructive  RPP  the No Break        DC range has an internal fuse which needs to be replaced if the battery is connected in reverse  Usually  however  a  reverse polarity connection results in instant destruction of the device  especially if there is a battery involved     Glossary of terms used in our user manuals    PSU   power supply unit BCT   battery condition test ECB   electronic circuit breaker  ELVD   electronic low voltage disconnect RPP   reverse polarity protection EMI   electromagnetic interference  SNMP   Simple Network Management LAN   local area network DOD   depth of discharge   Protocol    Specifications are subject to change without notice  No liability accepted for errors or omissions 2       ovative  energies    Global Solutions Personal Focus 100W Standalone PSU with battery backup       e Universal input  90  264VAC  127 370VDC   e High efficiency switch mode design   e Internal battery allows for high peak current draw  and back up on mains fail   e Internal diode in positive leg to prevent discharge  of battery while not in use   e 12V  7Ah battery included   e Easily removable lid for battery replacement   e Single  easy to use packag
2.  of 3 5mA     Ventilation   High operating temperature is a major cause of power supply failures  for example it has been well documented that a  10  C rise in the operating temperature of a component will halve its expected life  Therefore always ensure that there is  adequate ventilation for the equipment  Batteries and cooling fans also suffer shortened lifetimes if subjected to high  ambient temperatures   both should be included in a routine maintenance schedule to check for signs of reduced effi   ciency     Water   Dust   Every effort must be made in the installation to minimise the risk of ingress of water or dust  Water will almost always  cause instant failure  The effects of dust are slower in causing failure of electronic equipment but all electrical equip   ment should be cleaned free of any dust accumulation at regular intervals     Electromagnetic Interference  EMI    Switching power supplies and converters inherently generate electrical noise  All wiring should be as short as practica   ble and segregated from all equipment wiring which is sensitive to EMI  Residual noise can be reduced by looping DC  wiring through ferrite cable sleeves  These are most effective as close to the power supply as possible and as many  turns of the wire taken through the core    and   in the same direction  as the core will accommodate     Fuse ratings    Check that the wiring and fuses or MCBs match the rating of the PSU or converter  Note that the Innovative Energies  No Break 
3. Phone   64 9 835 0700  Fax   64 9 837 3446  NZ Freephone  0800 654 668    energies AU Freephone  1800 148 494    www innovative co nz    Global Solutions Personal Focus Email  info innovative co nz    User Manual    IEPS5    100W Standalone PSU with battery backup       T       7  Te  Li      ia       ISO9001  Certified       Specifications are subject to change without notice  No liability accepted for errors or omissions        energies    Global Solutions Personal Focus       Safety   The user is responsible for ensuring that input and output wiring segregation complies with local standards and that in  the use of the equipment  access is confined to operators and service personnel  A low resistance earth connection is  essential to ensure safety and additionally  satisfactory EMI suppression  see below      HAZARDOUS VOLTAGES EXIST WITHIN A POWER SUPPLY ENCLOSURE AND ANY REPAIRS MUST  BE CARRIED OUT BY A QUALIFIED SERVICEPERSON     Electrical Strength Tests   Components within the power supply responsible for providing the safety barrier between input and output are con   structed to provide electrical isolation as required by the relevant standard  However EMI filtering components could be  damaged as result of excessively long high voltage tests between input  output and ground  Please contact our techni   cians for advice regarding electric strength tests     Earth Leakage  The EMI suppression circuits causes earth leakage currents which may be to the maximum allowable
4. cifications are subject to change without notice  No liability accepted for errors or omissions 3    LY     TERMS OF WARRANTY    Innovative Energies Ltd warrants its power supplies for  24 months  two years  from date of shipment against  material and workmanship defects     Innovative Energies    liability under this warranty is lim   ited to the replacement or repair of the defective product  as long as the product has not been damaged through  misapplication  negligence  or unauthorized modification  or repair        Innovative Energies Limited    Phone   64 9 835 0700  Freephone  0800 654 668  New Zealand   1800 148 494  Australia     Fax   64 9 837 3446   Email  info innovative co nz   Online  www innovative co nz   In Person  1 Heremai Street  Henderson  Auckland  New Zealand    By Post  PO Box 19 501  Auckland 1746  New Zealand    energies        Thank you for purchasing from  Innovative Energies     We trust your power supply will exceed  your expectations and perform for years  to follow     Sincerely   The Innovative Energies team        so 900       23 12 11  4    
5. e   e 1509001 Design management system          24 Month Warranty       SPECIFICATIONS All specifications are typical at nominal input  full load and at 20  C unless otherwise stated                 PHYSICAL  Input voltage 85   265V  50 60Hz AC Input connector IEC320 socket  Fusing   Protection AC input fuse 3A DC Connections Banana plug screw terminal posts  DC battery output MCB 10A  PSU  constant current limit Enclosure Steel   powder coated lid  Overvoltage protection  Mounting Desktop  Control ON OFF switch on front panel  Isolation 1KV DC input   output   earth Dimensions 178 x 300 x 78 mm  W x D x H   Bower 100W  including rubber stand off feet   Weight  with batt  Output voltage 13 8V  mains on  Eden attery  5 Kg  Current 6 5A continuous  mains on   16A peak  mains on        Indicators Mains on  DC output present STANDARDS  EMI EN55022 2006  Class B   Battery 7Ah sealed lead acid  Estimated back up time at 6 5A   12 to 15 Safety EC950   EN60950   AS NZS3260   UL1950    minutes with battery in good condition  External batteries  properly fused  may be  connected for extra backup time or higher  peak currents        ACCESSORIES SUPPLIED  AC power cord 1 5m with IEC320 socket and NZ Aust plug                   MCB must be closed for  battery to be connected   MCB should be tripped  when in storage or if not  connected to mains power   Briefly connect DC output  terminals together to open  MCB     DC Output Terminals    AC Input Socket  Switch and  Fuse                Spe
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Greenmaster UB5 User's Manual  cadets-mode d`emploi  Philips Roller Brush CRP760  The Forever Cap LYM88 Installation Guide  NETWORK CLOCK  Installation and Instructions for Use BSDO69  Tripp Lite PDUMV15-36 power distribution unit PDU  LB0047-25(MAC_manual..  GEN-1700-iMS0 - Mi-T  FEUILLE D`AUTEUIL n°9 - Notre Dame d`Auteuil    Copyright © All rights reserved. 