1. nn ooo nn ceraaeereaanaaaaaaaa renerne renee 19 Communicator Testenine sinon einen seoan ene ELE A ako kabes ED ai a kaka dek finas E varn 20 Read Alarm FIISTONY cise scent teneb van n f e abs ia n a se m kf f n kd n Di ad 21 Fire Reset Fire Trouble cccccccccccccccceceeeeceeeeeeeeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseseeeeseeeeeeeeess 21 Remote Program Dial out and Answer oooronn r ono ooo nn nn 22 Error Displays sirene a e kaa bw ee r be B Da 23 Duress Code aeska ds sido fina VE ko ta ete Ps kn EP abi krk o TT an aa 25 MG UCSE COG ede kte irite ansan fow eds BE nn fa a aaa Dare oa 25 Emergency Procedures siccsecsseccteesehsecenecdee tee soa nn ne k n sken ki nn ka a Se ko kipa in mais na 25 Emergency Keypad Alarms issue aint dt ies eed ua Pola n ra rola 26 EF SANS oat hese ads teak cae E asa sce sa bees Mai a e ARE E eau viet bccn ka pen Pe ka EE a e a kd ee pea da ea 27 Page 2 This system includes a telephpne line seizure feature The system may be programmed to communicate with a central monitoring station to report system events You will not be able to use your phone while the system is communicating with the central monitor ing station In the unlikely event that the central station is not able to receive the report your phone may be unavailable for up to 20 minutes while the panel makes additional communications attempis Keypad Quick Reference Guide Turning On arming your
2. 8 Turning OFF disarming the System Silencing Alarms Please read Section 1 22 Emergency Procedures prior to being confronted with an emergency event If you have entered the building through a perimeter door you may hear a steady pre alert tone from the keypads If so disarm according to the chart below WARNING If the bells and sirens are on and or the red Armed light is flashing then the keypad is signaling that an alarm has occurred sometime before your arrival The DS7447 will display Zone Alarm The DS7443 or DS7445 zone LEDs will be flashing for the corresponding zone that is in alarm The keypad will also issue a pulsed tone during the entry delay instead of the usual steady tone If the alarm has not been previously investigated do not enter the building unless accompanied by the appropriate Emergency Services personnel This chart explains proper procedures for disarming and or silencing alarms TYPE OF DISARMING COMMAND WHAT WILL HAPPEN SEQUENCE Disarming the System PIN Off The red Armed light will turn off Pre alert sounders will silence Silencing Alarms PIN Off The red Armed light will turn off Zone LEDs on the DS7443 or DS7445 will turn off Alarms in progress will silence Turning Off disarming the System under Duress A duress code is used when someone demands by threatening your life or well being that the system be turned off When used the code will both turn off the sys
3. Sections 1 20 and 1 21 NOTE You cannot read back User PIN numbers You should keep a separate list for future reference Removing a PIN To remove a PIN enter a Master Code 4 0 the User Number of the PIN to be canceled and then again User Number 001 can not be canceled See Sections 1 20 and 1 21 for special uses for User Number 14 and 15 PINs Page 7 Page 8 Setting the Time This chart explains the procedure for changing the time at the keypad It is recommended that this procedure be performed at a DS 7447 keypad No visual cues will be given from a DS7443 or DS7445 keypad Steps to Change Command If A ted the Display R the Time Sequence se os ene b Enter the Master Code 6 Change Time Master Code 0 display will scroll to this Programming Mode 1 through 7 Enter Time Sunday Saturday 0100 1259 Enter the Time Enter AM PM Hour and minute O 1 0 0 through 1 2 5 9 4 6 End with 4 or 6 Day Time Miki 4 AM 6 PM A long beep signifies acceptance Enter the day Note Entering the command sequence Master Code 0 6 will cause the DS7447 keypad to read back the time The control panel will exit you from the master code programming mode after about 15 seconds without a keystroke 1 4 Setting the Date This chart explains the procedure for changing the date at the key pad It is recommended that this procedure be p
4. bypass one or more zones prior to arming the system Bypass commands only work when the control panel is disarmed For instance an open window may cause the DS7447 display to read Not Ready followed by the zone number The DS7443 or DS7445 may have one of its zone LEDs on steady Only one zone may be bypassed each time the command is used If more than one zone requires bypassing repeate the command for each zone to be bypassed NOTE See Section 1 9 Force Arming for another method of zone bypassing Page 15 Page 16 This chart explains the procedure for bypassing a faulted zone prior to arming the system COMMAND SEQUENCE TYPE OF BYPASSING DESIRED Bypass Faulted PIN Bypass Zone Zones WHAT WILL HAPPEN The Status light will begin to flash if no other zones are violated Read Bypassed Zones PIN Bypass Bypass will be displayed DS 7447 followed by the zone number of any bypassed zones The DS7443 or DS7445 will flash the zone LED of the zone being bypassed Clear Individual PIN Bypass Zone Bypassed Zone s Individual zone bypasses will be cleared PIN Bypass Clear all Bypasses All bypasses will be cleared If in Residential Mode substitute the key for the PIN NOTE All bypasses are cleared when the system is disarmed unless they are on 24 hour zones To clear a bypass on a 24 hour zone use Clear Individual or Clear All 1 12 Chime Mod
5. information on various control panel functions A built in sounder is used to annunciate keystroke entries and as an interior warning device Volume Control DS7445 and DS7447 only The keypad sounder volume can be adjusted using the 1 and 4 keys along with the key Hold the key while pressing the 1 key to increase the volume or the 4 key to decrease the volume The volume adjustment does not affect the volume during an alarm Backlight Control DS7447 only The display backlight intensity can be adjusted using the 3 and 6 keys along with the key Hold the key while pressing the 3 key to increase the brightness or the 6 key to decrease the brightness NOTE After the backlight and volume are adjusted you must arm then disarm the system once to store this information in the control panel These settings will be lost in the event of total power failure to the panel Amal E pous 6 a o Amed Prrimcter m oa e im nunnu E soa q eee O sos e VOS e ses e 0 0 Bs ooo ca 3 a x 00 4 Om aa DD CO amp e DD GD DS7447 KEYPAD DS7443 KEYPAD DS7445 KEYPAD This chart will help you understand what each light LED represents LIGHT FLASHING ON Armed The control panel is disarmed An exit de
6. occur in the home the majority during sleeping hours The minimum level of protection requires smoke detectors to be installed outside of each separate sleeping area and on each additional story of the dwelling For added early warning protection it is recommended that detectors be installed in all separated areas including the basement bedrooms dining room utility room furnace room and hallways Page 27 Page 28 Having and Practicing an Escape Plan A fire warning may be wasted unless the family has planned in advance for a rapid and safe exit from the building Draw a floor plan of the entire house showing two exits from each bedroom and two from the house Since stairwells and hallways may be blocked during a fire the plan should provide exits from bedroom windows Make copies of the plan and practice it with all family members Prearrange a meeting place outside and away from the residence Once out of the building all occupants should immediately go to the pre selected location to be accounted for Provide a barricade between family members and fire smoke and toxic gases e g close all bedroom doors before retiring Children should be instructed on opening their bedroom windows and exiting safely from the building If exiting is not possible they should be taught to stay at the open window and shout for help until it arrives In the event of a fire alarm after retiring wake the children by shouting to them from behind your cl
7. programmed to be a Guest Code After the Guest Code has been programmed it is enabled by depressing PIN 8 4 The Guest Code may now be used to arm and disarm the system It remains active until the panel is disarmed with any other valid code Ask your installation company if you desire this feature 1 22 Emergency Procedures Identifying Alarm Sounds Your alarm system may be programmed for a steady alarm sound or a pulsed alarm sound It is important to learn the difference between a fire alarm sound and an intrusion alarm sound before you are confronted with an actual emergency Silencing Alarms All alarms can be silenced with any PIN Entering your PIN Off will silence the alarm and turn off disarm the control A Cautionary Note How you respond to an alarm will depend mostly on the type and time of the alarm You should seek the advice of your installing company as they install your system not later e g after an alarm to develop a response plan Above All Else Common Sense Should Prevail If there is any threat or hint of danger to yourself or others on the premises such as in the event of a fire alarm everyone should be instructedto leave the premises immediately Do not enter the premises unless accompanied by the appropriate Emergency Services personnel or after they have given the OK to enter Page 25 Page 26 Caution When Entering A Building If the bells and sirens are on and or the red Armed light
8. 32 F 0 C Areas of high humidity and dust concentrations should be avoided The edge of ceiling mounted detectors should be no closer than 4 inches 10 cm from any wall Place the top edge of wall mounted detectors between 4 and 12 inches 10 to 30 cm from the ceiling Dinhg Kitchen Bedroom Room Rec Room Living Room Smoke Detector sk Smoke Detector Asmoke detector should be located on each Locate smoke detectors between sleeping story including basements but excluding crawl areas and family living areas spaces and unfinished attics For exact mounting information refer to the instructions provided with the smoke detectors Page 29 Example User 001 User 002 User 003 User 004 User 005 User 006 User 007 User 008 User 009 User 010 User 011 User 012 User 013 User 014 User 015 PIN NUMBER 1038 NAME Thomas J Brown Page 30 DEVICE LOCATION TYPE Example PIR KITCHEN Invisible alarm alarm on short alarm on open 24 hour Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Page 31 Index A Alarm Sounds 25 Arming Force Arming 14 Quick Arming 12 Turning ON Arming the System 10 Auto Bypass 15 Cc Chime Mode 17 D Duress Code 25 E Easy Exit 12 Emergency Alarm Keys 27 Emergency Keypad Alarms 26 Emergency Procedures 25 F Fire Alarms 26 Reset 21 Safety 27 Trouble 22 G Guest Code 25 K Keypads Backlight Control 4 DS7443 4 DS7445 4 DS
9. 7447 4 Volume Control 4 M Master Code 6 P Panic key 27 Personal Identification Numbers 6 Adding a PIN 6 Removing a PIN 7 R Read Alarm History 21 Remote Program Dial out and Answer 22 Remote Programming Answer for Remote Programming 22 Call for Remote Programming 22 S Silencing Alarms 25 T Tests Communicator Test 20 Local Battery Sounder Test 19 Z Zone Bypass 15 Test 17 Please contact your Installing Company at the above number Copyright 1996 98 Detection Systems Inc 130 Perinton Parkway Fairport New York USA 14450 9199 DS7060 Users Guide P N 29955E 11 98
10. E HAPPEN Local Battery Commercial Mode All keypad lights will turn on If test fails the control panel Sounder Test PIN 8 5 NOTE Zone lights on the DS7443 will indicate a contro problem and DS7445 will not tum on Residential Mode If power in your building has 8 5 The keypad sounder and all alarm been off recently wait 2 hours sounding devices will operate for 2 for the battery to recharge seconds and then try again Battery Test Commercial Mode The control panel will perform a battery PIN System Reset test Residential Mode If there is a Low Battery condition the System Reset control panel will report a Low Battery If the battery is now functional the control panel will report a battery restoral Page 19 Page 20 1 15 Communicator Test This test is only available if your system transmits alarms and system information to a monitoring service and has been programmed by the security installing company to permit communicator tests This test may only be used in the disarm mode A long beep will initially sound to acknowledge the start of the test If the test is successful the sounder will again issue one long beep If the test fails the keypad sounder will beep three times and the Power LED will begin to flash indicating a Control Trouble The DS7447 keypad will display Control Trouble Enter 87 When performing the 87 error display sequence the DS7447 keypad w
11. System Normal Arming Perimeter Arming no entry delay Perimeter Arming with entry delay Maximum Security Arming Force Arming Zone Bypass Custom Arm Quick Arm PIN On Turning Off disarming your System PIN Off PIN No Entry Perimeter Only PIN Perimeter Only PIN No Entry On PIN Arming Sequence Bypass PIN Bypass followed by the Zone number PIN 8 4 On Commands for other System Features Chime Mode Zone Test Read Alarm History Battery Test Communicator Test Fire Reset Fire Trouble Remote Program Dial Out Remote Program Answer Local Battery Sounder Test Error Display Error Display Reset Clear Zone Bypass Guest Code Enable PIN 7 PIN 8 1 PIN 8 9 PIN System Reset PIN 8 2 PIN System Reset PIN Off to silence PIN System Reset to clear PIN 8 3 PIN 8 6 PIN 8 5 PIN 8 7 PIN System Reset PIN Bypass to clear PIN 8 4 NOTE Examples are shown in Commercial Mode but are valid for any mode Page 3 Page 4 1 1 Understanding the DS7443 DS7445 and DS7447 Keypads The DS7443 is a 6 zone LED keypad its LEDs represent the zones of the system The DS7445 is an 8 zone LED keypad its LEDs represent the zones of the system LEDs for zones 7 and 8 are not used The DS7447 is an alpha numeric LCD keypad All three keypads display
12. User Numbers 001 015 Your system may have up to 15 different PINs each 4 digits long Each User Number can have only one PIN Attempting to assign the same PIN to multiple User Numbers will result in the three beep error tone and the change will not be made User Number 001 is designated as a Master Code It can be used to add delete read back or change other PINs User Number 001 is shipped from the factory with the sequence of 1234 This code should be changed to one of your personal preference PINs should never be programmed with common sequences such as 1111 or 2468 because they are easily violated Adding a PIN The following chart will guide you through the steps necessary to add or change a PIN Itis recommended that this procedure be performed at a DS7447 keypad No visual cues will be given from a DS7443 or DS7445 keypad STEPS TO CHANGE COMMAND SEQUENCE IF ACCEPTED A PIN THE DISPLAY READS 1 Enter the Master Code Master Code 0 O Change PIN Programming Mode display will scroll to this 2 Enter a 0 Enter User No 001 015 3 Enter the User Number 0 0 1 through 0 1 5 Enter PIN 4 Enter the PIN Any 4 digits Each user Enter PIN Again must have a different PIN End with 5 Enter the PIN again followed PIN same 4 digits as above A long beep will sound to by the key then signify acceptance of the new PIN NOTE Users 014 and 015 may be used for Duress and Guest Codes See
13. Using Your DS7060 Control Communicator a ros a Aa Ae Ea El om Gp XX e see eo 0 8 9 4 NH OE Ge eee e eee CAUTION OMNAOARWD a i mk m mk m mk m mk mk mk m mk HA i Contents Understanding the DS 7443 DS 7445 and DS7447 Keypads ne nen 4 Personal Identification Numbers nn r 6 Setting the TMS sereset na e aa a a e GEES Pan s tas Pou eE Zhu GAL Asid 8 Setting the Dale rsss re kaa be de ada a r e pk se kaa ka SOT p ey l lajk on lana klikania 9 Turning ON arming the System e tatatttttaeeeaaooooootasseeeasoooooooessesasooooooooosssoaoon 10 Quick Arming the System oo rn 12 EASY EE e ra lvl vol nor 12 Turning OFF disarming the System Silencing Alarms ooooovnnnnnonorrrnn nn 12 FOSE AMIN GE kai ate nan ko ae RR RO CR RO op On TD LO O b OR OE 14 Auto BY PASS frasa d ape ske ae don anti ove docs ve ka ti n srna rn lona v hla 15 Zone BYPASS kte soi t k bot pate te pe atan ae aara wawa at kasab Sep ee ao kan e it ok ta SAL s n ei Seara Pa 15 Chime MOG kr t SS or ke tete ho fan a ho R Rape po Gus Ur e a Pe a O ada Zone sh 17 ZONE TES tise aie tence ceeds ase a Sep Point Sree Da a poban do R N be op e Da anti pise bal 17 Local Battery Sounder Test
14. WILL occur upon entry Commercial Mode PIN No Entry On Residential Mode No Entry On The red Armed Light will begin to flash The green Status light will turn off Armed Instant will be displayed DS7447 Exit Now will display DS7447 during the exit delay interval Asingle beep will sound The red Armed light will turn on steady after the exit delay interval Exit during the exit delay interval CAUTION Violating any zone after the exit delay interval will cause an instant alarm Page 11 Page 12 1 6 Quick Arming the System If Quick Arming is not used a PIN must be entered at the beginning of all arming command sequences When Quick Arming is used the following shortcuts are available Ask your installation company if you desire this feature QUICK ARMING COMMAND SEQUENCE TYPE OF ARMING On Normal Arming H No Entry Perimeter Only Perimeter Instant Arming no entry delay Perimeter Only Perimeter Arming entry exit delay No Entry On Maximum Security Arming 1 7 Easy Exit lfthe system is armed and there have been no zones violated then you can reenter a Quick Arm Command without first disarming the system This allows you to change the arming level or to restart the exit delay so you can exit through an entry exit zone Easy Exit is disabled by default Ask your installation company if you desire this feature 1
15. d windows etc before using these features If the problem can not be corrected contact your installing company NOTE See Section 1 11 Zone Bypass for an alternate method of arming the system when faults exist Force arming is not available in U L Listed systems TYPE OF ARMING WHAT WILL HAPPEN WHAT TO DO WHAT WILL HAPPEN WHAT TO DO Force A5 second beep occurs Press Bypass The red Armed light will flash Exit during the Arming indicating there are faulted during the during the exit delay interval exit delay zones and that the control 5 second beep The control panel will arm with interval if Enter any panel needs to be Force the faulted zones bypassed or leaving arming sequence Armed a three beep error tone will occur indicating Force Arming has not been accepted or allowed 1 10 Auto Bypass The system can be armed and will automatically bypass faulted zones Ask your installation company if you desire this feature TYPE OF ARMING WHAT WILL HAPPEN WHAT WILL HAPPEN WHAT TO DO Auto Bypass Asingle beep occurs The red Armed light will flash Exit during the indicating that the panel during the exit delay interval exit delay has armed The control panel will arm with interval if the faulted zones bypassed or leaving a three beep error tone will occur indicating Auto Bypass has not been accepted or allowed 1 11 Zone Bypass There may be occasions when it is desirable or necessary to temporarily
16. e Chime Mode causes the keypad sounders to beep each time a Perimeter or Entry Exit zone is violated while the control panel is off disarmed Only your installation company can determine which zones are chime zones The 7 command is used to both turn Chime Mode off and on This chart explains the procedure for turning ON and turning OFF Chime Mode ACTION DESIRED COMMAND WHAT WILL HAPPEN SEQUENCE Turn ON PIN 7 The keypad sounders will beep for 2 seconds each Chime Mode time a perimeter or entry exit zone is violated The DS7447 display will read Chime Mode On for 5 seconds Turn OFF PIN 7 The DS7447 display will read Chime Mode Off for Chime Mode 5 seconds If in Residential Mode substitute the key for the PIN 1 13 Zone Test The Zone Test is used to confirm that detectors will report alarms Zone Test works on all zones except 24 hour zones and fire zones While the keypad is in Zone Test no control panel alarms will activate an alarm except 24 hour zone alarms and fire alarms These will override the Zone Test function Caution Be sure not to activate 24 hour or fire zones during the zone test or an alarm signal will be sent The Zone Test will initiate communicator reports only if both System in Test Report and System in Test Restoral Report are programmed Ask your installation company if you desire this feature Page 17 Page 18 WARNING Make sur
17. e that the report value programmed at these locations will be clearly understood at the Central Station The System in Test Report will be sent followed by the alarm and restoral reports of the zones being tested providing their corresponding report address is programmed After completion of the Zone Test the System in Test Restoral Report will be sent If these two reports are misunderstood then the zone alarms might be perceived as a real violation TYPE OF TEST COMMAND WHAT WILL WHAT TO DO SEQUENCE HAPPEN Zone Test Commercial Mode DS7443 DS7445 The zone LEDs will Test each detector one PIN 8 1 flash for any zones that have not been at a time as instructed tested by the installing Residential Mode DS7447 Test Zone will display followed company A 8 1 by the zone number of any zones that have not been tested To exit the Zone Test mode enter your PIN DS7443 DS7445 The zone LED will turn followed by or press on steady for the zone that is currently the key being violated tested DS7447 Now Testing will be followed by the zone number of the zone that is currently being voilated tested It returns to Test Zone after the violation 1 14 Local Battery Sounder Test This test uses the battery to manually activate all the system sounders for two seconds If the battery voltage is low a battery fault will occur TYPE OF TEST COMMAND WHAT WILL WHAT TO DO SEQUENC
18. erformed at a DS 7447 keypad No visual cues will be given from a DS7443 or DS7445 keypad Steps to Change Command d the Display R the Date Sequence Accepted e Display Reads Enter the Master Code 2 Change Date Programming Mode Master Code 5 0 display will scroll to this EN EE 0 1 through 1 2 Enter Day Enter January December 01 31 Enter the Day 0 1 through 3 1 e n The last two digits of the year Month Day Year Year dai Enter heder followed by the key A long beep signifies acceptance Note Entering the command sequence Master Code 0 2 will cause the DS7447 keypad to read back the date The control panel will exit you from the master code programming mode after about 15 seconds without a keystroke Page 9 Page 10 1 5 Turning ON arming the System The green Status light must be on steady and no zone lights are displayed on the DS 7443 or DS7445 keypad The DS7447 display must read Ready To Arm in order to arm the system with one of these commands Exception It is still possible to Perimeter Arm or Custom Arm the system if the Perimeter or Custom arm zones are in their normal condition even if the green Status light is off If the green Status light is not on or zone lights are displayed on the DS7443 or DS7445 keypad or if the DS7447 s display is reading Not Ready then see Section 1 9 Force Arming or Section 1 11 Z
19. gh the history line by line The 9 key will scroll you back in reverse order by event Pressing the 6 key will scroll you forward through the events towards the most recent by event Each event consists of two lines or display screens The first line screen will be the event title and user The second line screen will be the date of the event or the change being made To exit the History Mode press the key or wait 20 seconds and the keypad will exit automatically 1 17 Fire Reset Fire Trouble Fire Reset During a fire alarm exit the premises immediately When you have determined there is no fire you may silence the bells sirens before you can initiate the System Reset command PIN Off will silence the sounders This will allow a determination of which smoke detector has alarmed so the monitoring company may verify its operation A PIN followed by the System Reset key will reset any smoke detectors after a fire alarm has occurred The System Reset command will perform a fire reset will perform a battery test and will clear all system troubles Page 21 Page 22 Fire Trouble A Fire Trouble display signifies a problem with the fire system such as a break in the wiring that monitors smoke detectors A Fire Trouble will be indicated by a short beep from the keypad sounders every 10 seconds The DS7447 will display Fire Trouble followed by the zones in a trouble condition The DS7443 will turn the Fire light on steady and will
20. ill display Control Trouble Communication Err The DS7443 and DS7445 keypads will turn on the Zone 3 LED See Section 1 19 Error Displays TYPE OF TEST COMMAND WHAT WILL WHAT TO DO SEQUENCE HAPPEN Communicator Commercial Mode Along beep will sound If test fails the keypad Test PIN 8 2 sounder will beep 3 times A Test report is sent to the Residential Mode monitoring service NOTE This test may take 8 2 several minutes to complete because the control will try several attempts before it fails this test A retry will occur 30 minutes after failure and then 24 hours thereafter 1 16 Read Alarm History The history buffer stores the last 20 events in memory The DS7447 can display all of these events The DS7443 DS7445 can only display those zones 1 6 that have alarmed Command a T f Test What will Happen What to Do UDE Sequence i PP DS7447 Scroll through the DS7447 The last event to take place will be events by using the 9 6 and Event History PIN 4 8 9 displayed keys See below Readback DS7443 DS7445 The zone LEDs 1 8 will flash for any zones that have alarmed To exit from the Event History Mode press the key f in Residential mode a PIN is not required for this command DS7447 only Scrolling through history events To begin scrolling through the events press the key The key will scroll you back throu
21. is flashing with the DS7447 display reading Zone Alarm or the DS7443 or DS7445 having its zone LEDs flashing then the keypad is signaling that an alarm has occurred The keypad will also issue a pulsed tone during the entry delay instead of the usual steady tone If the alarm has not been previously investigated do not enter the building unless accompanied by the appropriate Emergency Services personnel Fire Alarms Fire Alarms are silenced by using the same procedure as intrusion alarms a PIN the Off key The Fire Alarm system is not reset until alarms at smoke detectors are cleared by using the System Reset command The Fire Alarm system will not be functional until this procedure has been followed See the Fire Reset section 1 23 Emergency Keypad Alarms DS7447 KEYPAD DS7443 KEYPAD DS7445 KEYPAD B Status 2 85 B Power a st FS o tunes one E os ORES O sua os osm SS 920280 Power a Power Bell Slenced S Fra Fre Trouble B Armed i 84 On sea a eee sea a e og e aa I a DOS amp oa G O e QO 6 aa m A B C V Hep W e ot so en ED P T P a s The Emergency Alarm Keys A B and C may generate Fire Special Emergency and Panic Alarms if programmed by the installer As
22. k your installing company to explain the function of these keys When using the Emergency Alarm Keys they must be pressed for two seconds to generate an alarm NOTE If the Emergency Alarm keys are to be used they should be labeled to signify their functions The A key should be labeled as the Fire key This is the only key that may be designated as the Fire key The B key should be labeled as the Help key The C key should be labeled as the Panic key Use the Disarming Command Sequence to cancel or silence these alarms 1 24 Fire Safety This fire alarm system can provide early warning of a developing fire Such a system however does not ensure protection against property damage or loss of life resulting from a fire Any fire alarm system may fail to warn for any number of reasons e g smoke not reaching a detector that is behind a closed door When considering detectors for residential applications refer to NFPA Standard 72 The National Fire Alarm Code This standard is available at a nominal cost from The National Fire Protection Association Batterymarch Park Quincy MA 02269 If Installed in Family Residences Adherence to the NFPA Standard 72 can lead to reasonable fire safety when the following items are practiced e Minimize hazards Avoid the three traditional fire killers smoking in bed leaving children home alone and cleaning with flammable liquids Provide a fire warning system Most fire deaths
23. lay is in progress or an alarm The control panel is armed and no alarms have red has occurred occurred Status One or more zones are not ready One or more zones are bypassed All zones are ready to arm green to arm Power The control panel has lost power Control panel problems See Section 5 17 Normal operation green No AC or battery Error Displays There are no fire alarms A fire zone is in alarm A fire trouble condition exists red Perimeter The perimeter is not armed This light will not flash The perimeter is armed yellow Supervisory This light will not be used by the Not used Not used yellow DS7060 Bell Silenced The bells do not need to be or This light will not flash The bells have been silenced To clear enter yellow have not been silenced Fire Reset command Trouble There are no trouble conditions This light will not flash Atrouble condition exists yellow Zone LEDs There are no zone alarms Azone 1 6 is in alarm Azone 1 6 is not ready to arm or if a fire zone a red trouble condition exists This light is present on the DS7445 only This light is on the DS7443 and DS7445 Page 5 Page 6 1 2 Personal Identification Numbers The Personal Identification Number PIN is the 4 digit code users enter at the keypad to gain access to the system A PIN may be assigned to each User Number 001 015 The User Number identifies each person using the system There are 15 possible
24. light the corresponding zone LEDs The DS7445 will turn the Fire and Trouble lights on steady and will light the corresponding zone LEDs Notify your installing company immediately if the Fire Trouble message is displayed The Fire Trouble beep can be silenced with any PIN followed by the Off key After problems have been remedied a PIN followed by System Reset should be entered to clear the Fire Trouble display 1 18 Remote Program Dial out and Answer Note These features should be used by qualified installation personnel only Call for Remote Programming This command can only be entered when the control is disarmed Phone numbers 1 and 3 must be programmed along with account code 1 The panel will call phone number 3 and attempt to connect for downloading While programming is underway the Status Armed and Power LEDs will flash If the panel is already using the phone line it will sound the three beep error tone Answer for Remote Programming The panel will automatically pick up the phone line to answer a remote programming call While programming is underway the Status Armed and Power LEDs will flash If the panel is already using the phone line for a report communication it will sound the three beep error tone This command can only be entered when the control is disarmed This chart will help you to call or answer the Remote Programmer TYPE OF FUNCTION COMMAND SEQUENCE WHAT WILL HAPPEN Remote Program Commercial M
25. ode The panel will call the remote Dial out PIN A 8 3 programmer Residential Mode HA 8 3 Remote Program Commercial Mode The panel will answer a call Answer PIN ff 8 6 from the remote programmer Residential Mode FA 8 6 Phone numbers 1 and 3 must be programmed Phone 1 Account Code must be programmed 1 19 Error Displays Control panel problems are indicated by a flashing green Power light The DS7447 display will also read Control Trouble Enter 8 7 The DS7443 and DS7445 will only flash the green Power light The error messages may only be read when the control is disarmed Contact your installing company if the problems persist ACTION DESIRED ACTION DESIRED Read the Error Display when the Green Commercial Mode Power light is flashing PIN 8 7 Residential Mode A 8 7 Clear Error Display Commercial Mode Caution Clear the error display only on the PIN System Reset advice of your installing company or if you are Residential Mode certain the problem has been remedied PIN System Reset Page 23 Page 24 Battery Trouble and Communicator Err displays must be cleared by the System Reset command sequence even after the problem has been remedied These displays will not self clear All the other error displays will self clear from the keypads once the problem has been remedied kk 1 DS7447 AC Power Failure DS7443 or DS7445 LED 1
26. one Bypass for other ways to arm the system NOTE In commercial burglar applications for U L Listed Requirements a ring back indication and bell test should be heard after arming closing If not heard call for service NOTE If the system has invisible zones that are not ready they will be displayed during the arming sequence The display of invisible zones will remain on until the zone is cleared or bypassed The chart below explains the five normal ways of arming the system TYPE OF ARMING DESIRED Normal Arming No one left on the premises An entry exit delay is in effect COMMAND SEQUENCE Commercial Mode PIN On Residential Mode On WHAT WILL HAPPEN The red Armed Light will begin to flash The green Status light will turn off Armed will be displayed DS7447 Exit Now will display DS7447 during the exit delay interval Asingle beep will sound The red Armed light will turn on steady after the exit delay interval WHAT TO DO Exit during the exit delay interval Perimeter Instant Arming Someone still on the premises There is NO entry delay in effect Commercial Mode PIN No Entry Perimeter Only Residential Mode No Entry Perimeter Only The red Armed Light will begin to flash Perimeter Inst will be displayed DS7447 Exit Now will display DS7447 during the exit delay interval A slngle beep willl sound The red Armed light
27. osed door Tell them to keep their bedroom doors closed If the top of your bedroom door is uncomfortably hot do not open it There is most likely fire intolerable heat or smoke on the other side Shout to all family members to keep their bedroom doors closed and to exit the building via alternate routes If the top of the door is not uncomfortably hot brace the bottom of the door with your foot and the top with one hand then open the door about one inch Be prepared to slam the door shut if there is any pressure against the door or if any hot air rushes in If there is no evidence of excessive heat or pressure leave the room and close the door behind you Shout appropriate instructions to all family members and immediately leave the building via the pre planned routes If heavy smoke is present drop to your hands and knees or crawl to remain below the smoke level Installation Considerations Proper location of detection devices is one of the most critical factors in a fire alarm system The following are some general considerations Smoke detectors should not be installed in dead air spaces or close to ventilating or air conditioning outlets because smoke may be circulated away from the detector Locations near air inlets should be favored Avoid areas subject to normal smoke concentrations such as kitchens garages or near fireplaces Do not install smoke detectors where normal area temperatures are above 100 F 38 C or below
28. tem and report a silent duress alarm if connected to a monitoring service User code 14 can be optionally configured as a duress code User code 14 will not arm the system or report duress if the system is not armed Extreme care should be used when entering your PIN to turn off the system so a duress code is not inadvertently entered User Code 14 is not a duress code by default You must program the control panel that User Code 14 is the duress code Ask your installation company if you desire this feature Page 13 Page 14 1 9 Force Arming When one or more zones are faulted the system may be Force Armed by bypassing the faulted zones The green Status light will be off on all keypads when Force Arming is required to arm the system The DS7447 display will read Not Ready or Fire Trouble if a fire zone is open and the DS 7443 and DS7445 zone LEDs 1 6 will be on if one of those zones is faulted Ask your installation company if you desire this feature Force Arming during an AC power failure Regular arming of the control panel is not permitted during an AC power failure Having to Force Arm serves as a warning that the control panel is operating under backup battery WARNING Bypassing or Force Arming removes some of your building s protection because it excludes the faulted zones from arming There fore an intrusion may not be detected or the detection may be delayed Always attempt to correct any zone problems close doors an
29. turns on steady There is a power failure and the panel is operating on backup battery 2 DS7447 Battery Trouble DS7443 or DS7445 LED 2 turns on steady If the system has just been through a power failure wait at least two hours for the battery to recharge then enter a PIN System Reset to perform a battery test 3 DS7447 Communicator Err DS7443 or DS7445 LED 3 turns on steady The communicator failed to communicate with the central station 4 DS7447 System Fault DS7443 or DS7445 LED 4 turns on steady Internal error in the control circuitry or optional circuitry These system faults are Ram Fault ROM Fault EEPROM Fault 5 DS7447 Keypad Fault DS7443 or DS7445 LED 5 turns on steady One of the keypads is not responding to the control panel 6 DS7447 Aux Power Fault DS7443 or DS7445 LED 6 turns on steady The auxiliary power has been shorted 7 DS7447 Zone Trouble DS7443 or DS7445 LED of the zone in trouble will light One of the zones is not responding to the control panel This may also be displayed during power up if so ignore 1 20 Duress Code User Code 14 may be used as a duress PIN number When the system is disarmed using this duress code a silent report is sent to the central station Duress codes are intended to be used when a user is forced to disarm the system Ask your installation company if you desire this feature 1 21 Guest Code User Code 15 may be
30. will turn on steady after the exit delay interval The yellow Perimeter light DS7443 DS7445 will turn on steady Only exterior protection zones will be armed Move freely around the interior Perimeter Arming Someone still on the premises An entry exit delay is in effect Commercial Mode PIN Perimeter Only Residential Mode Perimeter Only The red Armed Light will begin to flash Perlmeter On will be displayed DS7447 Exit Now will display DS7447 during the exit delay interval A single beep willl sound The red Armed light will turn on steady after the exit delay interval The yellow Perimeter light DS7443 DS7445 will turn on steady Only exterior protection zones will be armed Move freely around the interior Custom Arming if programmed Someone still on the premises An entry exit delay is in effect Commercial Mode PIN H 4 Residential Mode 4 The red Armed Light will begin to flash On Partial will be displayed DS7447 Exit Now will display DS7447 during the exit delay interval Asingle beep will sound The red Armed light will turn on steady after the exit delay interval Only the custom protection zones will be armed Only your installation company can change which zones are custom armed Do not violate any of the custom zones Maximum Security Arming No one left an the premises There is NO entry delay in effect An alarm