1. essen rn nnne 9 WanDag Remoto COS E 9 WinDadq Remote Storage Record Hanna aanak AABANG eo aede ae oo den ausus 11 Z 20mA Current Loop Meas rements a NADAANAN n i 11 IBI Miri AA et cnet eer 13 Sec SIE qe 15 UR RISO DIEM B d r pom 17 Table of Contents vii ALTHEN AL THEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual 1 Introduction This manual contains information designed to familiarize you with the features and functions of the DI 145 USB data acquisition starter kit These high end Starter kits contain features and functionality normally reserved for more expensive data acquisition systems Features The DI 145 data acquisition instrument is a portable data recording module that communicates through your com puter s USB port Power is derived from the interface port so no external power is required Features include e 4 fixed differential analog inputs protected to 150V transient e Two dedicated digital I O ports for Remote control protected to 30V e 10V full scale measurement range e 240 samples per second maximum sampling rate e A push button to tag remote events in WINDAQ software e Three status LEDs for easy notification of system stat
2. Controls Indicators and Connections 10 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual WINDAQ Remote Storage Record To use a switch closure or TTL signal to begin recording data remotely connect signal leads to the appropriate Remote Control Record terminals on the DI 145 as shown below Model DI 145 Data Acquisition Starter Kit www dataq com Analog Inputs 10 VFS 150 V max Remote Control Reserved 60060900090 BO Baa Jj Once the switch closure or TTL signal is connected activate Remote Storage Record through WINDAQ Acquisition Software Storage to Disk may be automatically placed on the rising or falling edge of the trigger signal Use the menu command Options Remote Storage 1 to set WINDAQ to begin recording on low to high transitions of the Record input Use the menu command Options gt Remote Storage 0 to set WINDAQ to begin recording on high to low transitions of the Record input 4 20mA Current Loop Measurements Use the following diagram for 4 20mA current loop measurement connections Shunt Resistor Model R250 D xew A 0GL SAA 0LF sindui Bojeuy yy Jeuejs uonisinboy ejeq wos be ep Mumm Str L IG IPPON SININNYLSNI OVLVG pu 0 3 o D Ie ej 3 ex peAlesey Gy woo bejep ye auemyos peojumoq Controls Indicators and Connections 11 ALTHEN A
3. Indicates power is applied via the USB cable Active Indicates the device is in use either by WINDAQ Acquisition Software or a custom user developed program Remote Indicates when the Event Button is pushed or the Event terminals are connected via a relay contact or digital input Controls Indicators and Connections 13 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual 5 DI 145 Block Diagram 0 01uf 160K 10 EEPROM Calibration Model V 160K Aa og Serial Typical 4 places ZEE Event Au Analog In 2 UR ad TG SPI Port O z Remote ES V A D E d AN3 Analog In 3 E V t0 O 7 Active O V o D V Be a O Z Power AINA Analog In 4 a V V 10 D Reg 03 O Z buo Digital In 0 bii Remote Events m 10 o 2 ATMEL Microcontroller pw GC IN 47K Panel Remote Start Stop 4 7K V Digital In Vaias Vo Vcc Typical 2 places Panel Block Diagram 15 ALTHEN AL THEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual 6
4. 6195 70060 e info althen de www althen de DI 145 Hardware Manual 3 nstallation The following items are included with each WINDAQ Starter Kit Verify that you have the following e A DI 145 USB data acquisition instrument e USB cable e A DATAQ Instruments screwdriver for signal lead connections If an item 1s missing or damaged call DATAQ Instruments at 330 668 1444 We will guide you through the appropri ate steps for replacing missing or damaged items Save the original packing material in the unlikely event that your unit must for any reason be sent back to DATAQ Instruments Installing WINDAQ Software and the DATAQ Instruments Hardware Manager All software for the DI 145 can be installed via a downloadable executable directly from the DATAQ Instruments web site No CD is shipped with the device You may burn the executable onto a CD to transport the software to a computer with no internet connection 1 Disconnect all DATAQ Instruments USB devices from your Computer uii s E e 2 Goto www dataq com 145 in your web browser 3 Click on the Download Now button 4 Save the file to your local hard drive 5 Double click on the downloaded file dataq 145 install exe to extract the program and begin software installa tion 6 Follow the on screen prompts and enter any required information Installation 5 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060
5. Dimensional Drawing 1 612 nb L b 500 Dimensional Drawing 17 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de Bi INSTRUMENTS DATAQ Instruments Inc 241 Springside Drive Akron Ohio 44333 ALT HEN MESS UND SENSORTECHNIK ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de
6. by clicking on View Help in the Help menu or by press ing F1 Help All WINDAQ software utilizes context sensitive help Help may be accessed through the Help menu or by pressing the F1 key with any pull down menu item selected This will take you directly to the Help topic most relevant to that par ticular function or feature Help topics discuss in detail each function available in the software Introduction 2 ALTHEN AL THEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual 2 Specifications Analog Inputs Number of Channels Channel Configuration Voltage Measurement Range Input Impedance Isolation Accuracy Overall inaccuracy DC common mode rejection Max input without damage Max common mode voltage Analog frequency response Digital Inputs Number of Channels Pull up value Pull down value Input high voltage threshold Input low voltage threshold Absolute maximum values 4 Differential 110V Full Scale IMO each input to ground none 0 25 of FSR 64mV at 25 C 40 db at 25 C 75 V peak continuous 150 V peak one minute or less 10V 3db 100 Hz 2 47 KQ from input to to 3 3V 4 7 KQ from input to USB ground 1 8 V minimum 1 4 V maximum 30 VDC Reserved Inputs Digital Inputs Digital In 0 Digital In 1 ADC Characteristics Resolution Max sample throughp
7. de www althen de ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual Table of Contents Warrant and Service Pole a E E E iii iscritte TN 1 EE been 1 Andon DULO MERERETUR 1 brine AA 1 EE EE 1 WinDag Recording and Playback Software 111111117 1 The DATAQ Instruments Hardware Manager 2 li E 2 VITSE DIDI ETT T TIT 3 Tritani d AA 3 IBI IE Bn eis PN O TAOS AA AA 3 Reserved Inputs Digital Inputs esos onse once eta ott nett t eott epu ts tee dax AA 3 PDC CHAT NG EE 3 Indicators and C Ofmncc ee assassins NA AA AA ANA ANAN NI MM Ie ea US 3 lii Y 4 Iure AA OAS 4 eenegen 4 BVO yy AEG DUDDODE 25599 E E ioo eet vate teresa e Do En cus asa ems E n cuba e bas 4 So DOSEN M 5 Installing WinDaq Software and the DATAQ Instruments Hardware Manager 5 Connecting the Instrument to Your Computer 11111111111171 Aa 6 DATAQ Instruments Hardware Manager sesenta 6 4 Controls Indicators and Connections ecce eee eee eee e eee eene e e etes nete sese ees KEE RE EE EEEE RE ER EEN 7 Mini RE E EE E Ga AA sesen EA E S E E A S I RIES ER ee EE 7 Oe CU SISpal LAT eene 8 WinDaq Remote Controls Digital Inputs
8. e info althen de www althen de DI 145 Hardware Manual 7 Software installation is complete you will now see a Successful Installation box click OK to exit WINDAQ Installation You can now plug the device s into your PC Click on the appropriate program group specified above default is Start gt Programs gt WINDAQ and click on DATAQ Instruments Hardware Manager to access WINDAQ software Connecting the Instrument to Your Computer DI 145 instruments can be connected to your computer s USB port using the provided USB cable No external power is required Connect one end of the communications cable to the instrument port and the other to your PC s port Note Use a powered USB hub or a USB port on your PC Non powered USB hubs may not have sufficient power to run the instrument DATAQ Instruments Hardware Manager The DATAQ Instruments Hardware Manager is installed when installing any DI 145 instrument This software allows you to effectively manage multiple devices installed on the same PC The DATAQ Instruments Hardware Manager may be accessed through the Windows Program Manager Group as specified during installation default is Start gt Programs gt WINDAQ gt DATAQ Instruments Hardware Manager All available devices will automatically appear in the list box when you run the software y DATAQ Instruments Hardware Manager Allow 15 seconds for devices to appear Description Status Serlaltt IP Address 4058 90
9. the signal wire and not the wire insulation Do not over tighten 3 Tug gently on the signal lead to ensure that it is firmly secured Loosen l Tighten Screwdriver P aha Terminal Block Signal Lead When an input signal is connected and WINDAQ Acquisition software is run WINDAQ s real time display immedi ately reveals the input waveform on your computer s monitor Pressure Flap Controls Indicators and Connections 8 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual WiNDAQ Remote Controls Digital Inputs The DI 145 contains 2 digital inputs for WINDAQ Remote Events inserts an Event Marker and Remote Storage Record data Valid remote record and event signals are switch closures or discrete levels with a maximum input of 30 V and a threshold of 1 8 V TTL Switch Closure 30V Max 1 8V Threshold 0V WINDAQ Remote Events To use a switch closure or TTL signal to record WINDAQ Event Markers connect signal leads to the appropriate Remote Control Event terminals on the DI 145 as shown below Model DI 145 Data Acquisition Starter Kit e www dataq com Analog inputs 10 VFS 150 V max Remote Control Reserved BOB00000 Jj Once the switch closure or TTL signal is connected activate Remote Events through WINDAQ Acquisition Software Fvents may be automatically placed on the ri
10. 3E BIBLE Available 4056 S03E M tA v1 43 Settings for 4D 5BS 3E Update List ang Help The Hardware Manager allows you to start WINDAQ Acquisition software select the device and click on the Start Windaq button and must be used when multiple DATAQ Instruments devices are installed It also provides crucial information about your device needed for custom programming Serial and COM Port Please note The description of DI 145 models cannot be modified Click on the Help button for help with the DATAQ Instruments Hardware Manager Installation 6 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual 4 Controls Indicators and Connections SD Card Slot Model DI 145 not used in DI 145 Data Acquisition Starter Kit Event Marker Push Button d DATA j Download software Power Active and Bip Remote LEDs www dataq com Analog inputs 10 VFS 150 V max Remote Control Reserved HO 60 60 6 oe 6 9 O 9 G 9 amp OOOO 0 D 6 26 O C9 Q9 CO Bulkhead Mounting Ear Bulkhead Mounting Ear Mini B USB Connection Analog In Digital In Reserved Channels 1 4 Channels no connection Please note The SD card slot is not used in the DI 145 Allowing foreign materials to enter the device through the SD card slot may result in damage to the instrument Mini B USB Connection Use the s
11. LTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual The shunt resistor should be placed on the low side of the circuit as shown below Current Loop Transmitter Loop Power Supply 2500 Shunt Resistor To DI 145 Analog Input Channel Set the engineering units as desired and define low high calibration values in WINDAQ as IV 4mA for the low value and 5V 20mA for the high value For example when using WINDAQ Acquisition software in the Channel 1 Low Calibration dialog box Channel 1 Low Calibration Input Level 1 Volt Low Cal Value 4 Engr Units m Cancel Controls Indicators and Connections 12 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual In the High Calibration dialog box Channel 1 High Calibration Input Calibrator Calibrator Input Level Units Yalue Low 1 000 Vult 4 000 High Vult 20 mA Enter the following values the Low Cal values are displayed Calibrator Input Level Calibrator Value Engr Units You can also associate these values to a physical measurement such as pressure load flow torque etc Read the Help files for more information regarding Waveform Calibration LED Indicators The DI 145 provides three green LEDs for instrument status and notification Power
12. PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER DATAQ N J INSTRUMENTS The way PC based instrumentation should be DI 145 4 Channel USB Data Acquisition Starter Kit User s Manual Manual Revision C Copyright 2012 by DATAQ Instruments Inc The Information contained herein is the exclusive property of DATAQ Instruments Inc except as otherwise indicated and shall not be reproduced transmitted transcribed stored in a retrieval system or translated into any human or computer language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without expressed written authorization from the com pany The distribution of this material outside the company may occur only as authorized by the company in writing DATAQ Instruments hardware and software products are not designed to be used in the diagnosis and treatment of humans nor are they to be used as critical components in any life support systems whose failure to perform can rea sonably be expected to cause significant injury to humans DATAQ the DATAQ logo and WINDAQ are registered trademarks of DATAQ Instruments Inc All rights reserved ACCURATE ALTHEN SOPHISTICATED MESS UND SENSORTECHNIK SINCE 1978 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de Warranty a
13. e www dataq com WINDAQ Acquisition software WINDAQ Lite can be used to record waveforms directly and continuously to disk while monitoring a real time display of the waveforms on screen It operates displays and records waveform signals in real time at the full sample rate of the DI 145 240Hz maximum throughput Introduction 1 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual WINDAQ Waveform Browser playback software also known as WWB offers an easy way to review and analyze acquired waveforms A built in data file translator allows the user to display multiple waveforms acquired by WINDAQ Acquisition software or any of a wide range of data acquisition packages The software s disk streaming design allows data files of any length to be graphically displayed rapidly in normal or reverse time directions Seven standard cursor based measurements frequency domain and statistical analysis functions help simplify waveform analysis and interpretation WINDAQ Waveform Browser is free and installed when installing WINDAQ Software The DATAQ Instruments Hardware Manager This software can be found in the Start menu under the WINDAQ program group called DATAQ Instruments Hard ware Manager Access WINDAQ Acquisition software and manage multiple DATAQ Instruments devices in this easy to use point and click environment View the Help files
14. nd Service Policy Product Warranty DATAQ Instruments Inc warrants that this hardware will be free from defects in materials and workmanship under normal use and service for a period of 90 days from the date of shipment DATAQ Instruments obligations under this warranty shall not arise until the defective material is shipped freight prepaid to DATAQ Instruments The only responsibility of DATAQ Instruments under this warranty is to repair or replace at its discretion and on a free of charge basis the defective material This warranty does not extend to products that have been repaired or altered by persons other than DATAQ Instru ments employees or products that have been subjected to misuse neglect improper installation or accident DATAQ Instruments shall have no liability for incidental or consequential damages of any kind arising out of the sale installation or use of its products Service Policy 1 All products returned to DATAQ Instruments for service regardless of warranty status must be on a freight pre paid basis 2 DATAQ Instruments will repair or replace any defective product within 5 days of its receipt 3 For in warranty repairs DATAQ Instruments will return repaired items to the buyer freight prepaid Out of war ranty repairs will be returned with freight prepaid and added to the service invoice iii ALTHEN AL THEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen
15. sing or falling edge of the trigger signal Use the menu command Options gt Remote Events to set WINDAQ to place event markers on low to high transitions of the Event input Use the menu command Options Remote Events to set WINDAQ to place event markers on high to low transi tions of the Event input Controls Indicators and Connections 9 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual Event markers may also be placed in your data file manually by pressing the push button on the DI 145 Instrument You must enable Remote Events in WINDAQ to use the button use the menu command Options gt Remote Events tor Options Remote Events Model DI 145 Data Acquisition Starter Kit www dataq com Analog inputs 10 VFS 150 V max Remote Control Reserved eoeoeocG An example event marker in a WINDAQ data file is shown below Event Marker u WINDAQ Hydr tic Actuator Qualification wdg File Edit view Search saing Transform xY Options Help 1 D 9 153 D iakasialansallinsalliinsalliuuasalisasalsasalitacalizanilicanelzesuaslusuasdzusasizusasiusanlasanlassubasiualkansaslansaltvasalsissaliuansalsa BASE 79 3680 SEC TBF 0816 SEC TM 62 4 EOF T 0080 SEC DIV 4 Please Note Event Markers do not display in the real time WINDAQ acquisition software they only display in the WINDAQ playback software WWB
16. upplied USB cable to connect and power the instrument through your computer s USB port Connecting Input Signals All input signal connections are made to the 16 port screw terminals Each terminal is labeled directly on the instru ment case DI 145 Signal Connections Refer to the following for screw terminal port identification Ch Analog channels 1 4 10VFS 150V transient Max Remote Control Event Digital Input bit 09 Remote Event Marker Remote Control Record Digital Input bit 1 Remote Start Stop Reserved NC No connection reserved Model DI 145 Data Acquisition Starter Kit SCH e BiPATAG www dataq com Analog Inputs 10 VFS 150 V max Remote Control Reserved Controls Indicators and Connections 7 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual Use the following diagram to connect Analog Input Channel 1 Model DI 145 Data Acquisition Starter Kit DA AQ Download software at dataq com 145 INSTRUMENTS www dataq com Analog inputs 10 VFS 150 V max Remote Control Reserved Jj Connecting Signal Leads To connect signal leads to the DI 145 1 Insert the stripped end of a signal lead into the desired terminal directly under the screw 2 Tighten the pressure flap by rotating the screw clockwise with a small screwdriver Make sure that the pressure flap tightens only against
17. us e Backwards compatible with the DI 194RS serial port data acquisition system protocol Analog Inputs The DI 145 features four differential channel inputs located on a single sixteen position screw terminal block for easy connection and operation other terminals used for digital I O or reserved Note The DI 145 does not support Gain Utilize the functionality of WINDAQ software to experience all the features encased in these small inexpensive instruments Digital Inputs The DI 145 contains two digital lines bits for WINDAQ remote control operations Remote Start Stop and Remote Events Connect switch closures or discrete levels with a maximum input of 30V and a threshold of 1 8V The inputs float at 1 level about 3 3V relative to the terminal and require sinking about 50uA to bring them down to 0 8V and guarantee a 0 When no Options Remote are enabled in WINDAQ the Event input appears inverted in data bit 0 and the Record input appears inverted in data bit 1 of data for the first enabled channel Software All software required to record and playback waveforms is included with the purchase of any DI 145 data acquisition starter kit via download WiNDAQ Recording and Playback Software WINDAQ Acquisition and WINDAQ Waveform Browser allow you to record and playback data acquired through your instrument WINDAQ software is an invaluable resource to record and analyze your data and is available for free from our web sit
18. ut rate Min sample throughput rate Sample rate timing accuracy Indicators and Connections Interface Indicators LED Input Connections WINDAQ remote start stop WINDAQ remote events Overall 1 part in 1 024 10 bit Above zero part in 511 Below zero 1 part in 512 1 ADC Count 19 5 mV 240 Hz 0 44 samples per minute 50 ppm USB 2 0 mini B style connector Power Active Digital One 16 position terminal strip Specifications 3 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de DI 145 Hardware Manual Power Power Consumption Environmental Operating Temperature Operating Humidity storage Temperature Storage Humidity Physical Characteristics Enclosure Mounting Dimensions Weight Software Support WINDAQO Lite software Backwards compatibility Programming 0 30 watts via USB interface 0 C to 35 C 32 F to 95 F 0 to 90 non condensing 20 C to 45 C 4 F to 113 F 0 to 90 non condensing Hardened Plastic Desktop bulkhead 2 625D x 5 5W x 1 53H in 6 67D x 13 97W x 3 89H cm 3 6 oz OS support Windows XP 32 bit Windows Vista and Windows 7 32 and 64 bit versions sample Rate Limit 240 Hz DI 194RS compatibility mode supports Linux and MatLab DATAQ Instruments SDK Specifications 4 ALTHEN AL THEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0